November 29, 1989 Docket Nos.
50-269, 50-270, and 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242
Dear Mr. Tucker:
SUBJECT:
SAFETY EVALUATION FOR FINAL DESIGN OF OCONEE ATWS MODIFICATION (TACS 59119/59120/59121)
Your letter dated August 30, 1989, forwarded the final design description of the proposed Anticipated Transients Without Scram (ATWS) modification for the Oconee Nuclear Station. The NRC staff has completed review of this design.
Enclosed is the related Safety Evaluation.
The staff has concluded that the plant-specific design proposed for the Oconee Nuclear Station is in compliance with the rule requirements of 10 CFR 50.62, paragraphs (c)1 and (c)2. Paragraph (c)1 defines the requirements for the ATWS Mitigation System Actuation Circuitry (AMSAC) and paragraph (c)2 defines the requirements for the Diverse Scram System (DSS).
The staff is presently evaluating the need for Technical Specification (TS) operability and surveillance requirements for these systems. Guidance regarding TS requirements will be promulgated at a later date.
- However, installation of the ATWS modification should not be delayed pending the receipt of this guidance.
Sincerely,
/s/
Leonard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -
I/Il Office of Nuclear Reactor Regulation
Enclosure:
As stated
-O cc w/enclosure:
See next page DISTRIBUTION Docket File L. Wiens 14-H-25 NRC PDR OGC (For inform. Only) 15-B-18 Q
Local PDR E. Jordan MNBB-3302 PDII-3 Reading ACRS (10)
P-315 S. Varga 14-E-4 S. Newberry 7-E-12 G. Lainas 14-H-3 V. Thomas 7-E-12 D. Matthews 14-H-25 D. Lynch 13-E-21 R. Ingram 14-H-25
[Oconee Plant File]
OFC :LA:PDII-3
- PM: _PII-3
- D:
NAME :RIngr;n
- iens:cb
- DMa hews DATE :IT/J.1/89
//89
- /
OFFICIAL RECORD COPY r
Document Name: TUCKER LTR 11/15
Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:
Mr. A. V. Carr, Esq.
Mr. Paul Guill Duke Power Company Duke Power Company P. 0.. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.
Bishop, Cook, Purcell & Reynolds Mr. Alan R. Herdt, Chief 1400 L Street, N.W.
Project branch #3 Washington, D.C. 20005 U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 M-r.
Robert B. Borsum Atlarta, Georgia 30323 Babcock 8 Wilcox Nuclear Power Division Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike N. C. Department of Justice Rockville, Maryland 20852 P.O. Box 629 Raleigh, North Carolina 27602 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 34623-1693 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Heyward.G.
Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 County Supervisur of Oconee County Walhalla, South Carolina 20621