302846, Sheet Na, Rev 021, Chilled Water Service Bldg Flow Diagram
ML16130A438
Person / Time
Site: Crane 
(DPR-050)
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16130A438 (1)


Text

H G

F E

jo I

le B

A 8

7 6

3" 2 1/2" 2 1/2" 3"

2 1/2" 12 1/2'

'-D CH-V98 CH-V6A CVCH-V9A 2 1/2" 2 1/2" CH-V52 CH-V53 2"

2" 1/2" 2"

3" 3"

CH-V5A CH-V58'XCH-V50 Y CH-V5C 2"

2" 2"

2" 2"

3/4" 3/4" CH-V2G AH - E-35 CH-V2H AH-E- 33 CH-V48 CH-V2E 1----1 1 1/2" J

CH - V2D 3"

3/4" CH-V2N CH-V2P

'-D CH-VS 8

3" Tl 1019 3/4" CH-XJ-34 CH-XJ-33 3"

~ 4" AH - C-38 t

CH - V30 1/4" 2 1 / 2" 12 1 /2" 12 1 /2" 12 1 /2" SC-XJ - 298 (TI\\___

~I 1/2" 7

SC - ~J-29 A t )SC-XJ-30At j SC-XJ-308 1021 3"

3"

  • '3/4" SC - V192 6

VENTr.i3/ 4" 1 1/2" SC-V205 J"

5 4

I 3

I 2

I 1

CH-V68 1/2" 2"

CH-V29 1/2" 1/2" 4

~ o~?i~E PLA TE CH-V12 1"

CH-XJ-32 CH-V3C CHILLED WATER CHEMICAL MIX TA ~ K 4"

4" 5

AH - P-5 TO SC-V19 302-2 21 (D - 8)

FROM SC-V12 302 221 (E 8) 1" CH-V3A CH-V28 3/4" FILL ANO MAKE-UP WATER 4

3 302-003 302-002 302.::.-001 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTA TION SYMBOLS FLOW DIAGRAM 2

REVISIONS REV I ZONE DESCRIPTION 21 I C-3 !ADMINISTRA TIVE REVISION TO CORRECT VA LVE TYPE ( IR 2533490)

NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSI TIONS CONTROLLED BY PROCEDURES 2

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERW1SE NOTED

3. SET POIN T VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE Cod Fil e Nome: 302846_ R21 H

G F

E D

c z

0' 0

Co

~

~

~I I

THIS IS A COMPUTER z

GENERATED DRAWING DO Am G NOT RE ~SE IT MANUALL y er en

)>

CHILLED WATER SERVICE BUILDING A

FLOW DIAGRAM

~.

TMl-1 302-846 N/ A 121 L ______ __ _

_____ __ ____ __ _____ ____ ___ ___ __ _____ __ ____ ___ _J

H G

F E

jo I

le B

A 8

7 6

3" 2 1/2" 2 1/2" 3"

2 1/2" 12 1/2'

'-D CH-V98 CH-V6A CVCH-V9A 2 1/2" 2 1/2" CH-V52 CH-V53 2"

2" 1/2" 2"

3" 3"

CH-V5A CH-V58'XCH-V50 Y CH-V5C 2"

2" 2"

2" 2"

3/4" 3/4" CH-V2G AH - E-35 CH-V2H AH-E- 33 CH-V48 CH-V2E 1----1 1 1/2" J

CH - V2D 3"

3/4" CH-V2N CH-V2P

'-D CH-VS 8

3" Tl 1019 3/4" CH-XJ-34 CH-XJ-33 3"

~ 4" AH - C-38 t

CH - V30 1/4" 2 1 / 2" 12 1 /2" 12 1 /2" 12 1 /2" SC-XJ - 298 (TI\\___

~I 1/2" 7

SC - ~J-29 A t )SC-XJ-30At j SC-XJ-308 1021 3"

3"

  • '3/4" SC - V192 6

VENTr.i3/ 4" 1 1/2" SC-V205 J"

5 4

I 3

I 2

I 1

CH-V68 1/2" 2"

CH-V29 1/2" 1/2" 4

~ o~?i~E PLA TE CH-V12 1"

CH-XJ-32 CH-V3C CHILLED WATER CHEMICAL MIX TA ~ K 4"

4" 5

AH - P-5 TO SC-V19 302-2 21 (D - 8)

FROM SC-V12 302 221 (E 8) 1" CH-V3A CH-V28 3/4" FILL ANO MAKE-UP WATER 4

3 302-003 302-002 302.::.-001 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTA TION SYMBOLS FLOW DIAGRAM 2

REVISIONS REV I ZONE DESCRIPTION 21 I C-3 !ADMINISTRA TIVE REVISION TO CORRECT VA LVE TYPE ( IR 2533490)

NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSI TIONS CONTROLLED BY PROCEDURES 2

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERW1SE NOTED

3. SET POIN T VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE Cod Fil e Nome: 302846_ R21 H

G F

E D

c z

0' 0

Co

~

~

~I I

THIS IS A COMPUTER z

GENERATED DRAWING DO Am G NOT RE ~SE IT MANUALL y er en

)>

CHILLED WATER SERVICE BUILDING A

FLOW DIAGRAM

~.

TMl-1 302-846 N/ A 121 L ______ __ _

_____ __ ____ __ _____ ____ ___ ___ __ _____ __ ____ ___ _J