ML16130A403
| ML16130A403 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 04/11/2016 |
| From: | Exelon Generation Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16127A520 | List:
|
| References | |
| TMI-16-035 | |
| Download: ML16130A403 (1) | |
Text
7 8
I I
- H I
I I
IG I
I I
FROM DH-Y52 302-640 (H-5 FROM SF-V40 302-630 (C-2 SPENT FUEL COOLING SYSTEM ITI*HS DWG (F-7 FROM WOL-V47,48 TI-US DWG (C 8 3"
~21/2" 302-690 (E-2)
FROM WDL-V70,71 3"
THIS DWG (o-a*
t.2"~
WOL-V386~
2 1/2a I
©
~85
"'L-V279 T-- E'T' Alif I
EVENT 3"
(3~~.';~(;=~ I 3" 1~~~~
FROM WDL-P-7A~ 1 1/2a 302-690 (8-3" 3"
1 1/2" 3"
6 3"
WDL-V40 2 1/2" 3"
3" 12 1/2" 3"
I 5
2" DRAIN HOR. PT-6 302-690 (D-8' WDL-V387 1/2" t~~
302-669 2"
PRECOAT FILTER WDL-F-16 3"
2 1 VENT HOR. PT-5 302 690 (C 7) 1 1/2" q').P r 3"
'* '"". fG ~'WDL-V278
~
I WDL-V284 1/4"
~*
,5 3"
302-692 {H-7 Fl-137 1 1/4" 2"
DEBORAT!NG DEMlNERALIZER WDL-K-1A WDL-V204 2,, SAMPLE 3
2 1/2" 2"
1/2" er..
11 112;.
2 WDL-V203 REVISIONS REV I ZONE 9 I VARESI REVISED TO INCORPORATE ECR-14-00032 REV. 2 WDL-V7
-1"-Q)
AIR SUPPLY
~,~
.. gii 12* I 1*
11~
DEBORATING DEMINERALIZER WDL-K-16 WDL-V205
~
~N~
TAGGED VALVE SOLENOID HOOK-UP FOR VALVES MARKED "'
V.-OL-V209 1 1/4" SEE 302-671 AREA G-4 2"
SAMPLE TO WDL-VlO 302-692 (C-1 O)_
H G
1 1/4"
~gt r-... u.,..-
I.
.. i I.
Y 2..
2 n~
F 2 1/2" I
.\\.V,, 2f _, '
3" (SEE NOTE 10) I 11-lXJ'-"-li I
1 3"
~
~--------~*----~...... ~!
WOL-V69 F
I I
E D
le I
I I
B A
L __
2 1/2" 3"
11/2"~
WDL-V432 VENT HDR. PT.5 302-690 (D-7 1HIS DWG ( C-8)
SEE 302-671 AREA G-2 TO WDL-T-4
(}02-693 Qi=BLJ-1HIS DWG (F-8)
TO WDL-V52 THIS DWG (G-8)
TO WDL-V363 302-692 (F-10)
FROM WDL-V434 THIS DWG (E-8 t/2" 1/2" 2" I 2" 1 1/2" S-11 S-11 2*
1 1/2" I
I CATION DEMINERALIZER WDL-K-2A 2"
WDL-V213 WDL-V215 WDL-V733 3"
3" 2"
1 1/2° NON-NU, N-3 RECLAIMED WATER a
I 302 669 (E 3) )
1 1/ 2
- 4 1 1/2" WDL-V318 IFROM FLOOR DRAINS ~
ATMOS.
1 1/2" 3*
4" LAUNDRY ~~ir:: STORAGE I I 2"
D 1 1 /2" I
y WDL-V155 8
WDL-T-12 2*
T WDL-V678 y
WDL-P-15 LAUNDRY WASTE PUMP 7
WOL-V192 WDL-V350 WDL-V159
~
T "2:V
, 1/2" WDL-V156 2 1/2" WDL-V46
-1 h 1/2" 2 1/2" 3"
WDL-V41 2 1/2" 1 1/2" 1 1/2" 2" 12
1/2" L___/FE\\
~
1 1/2" 1 1/2" 3"
WDL-V157*
6 2"
WDL-V67 1/2" WDL-V271 CATION 1 lli 2"
I I DEMINERALIZER
~
WDL-K-26 2"
1 1/2" 2"
WDL-V214 RECLAIMED WATER 302-669 {E-3) 1 1/2°
-,_'u I o:::J V> zZ Ji WDL-V316 WDL-V190 I.
1/2" WOL-~
r.V V153 I. U y
1 1/2"
~
~
1 1/2" 1 1/2" 1 1/2" 1 1/2" Vv0L-V151 WDL-V366 TO MISC WASTE EVAP.
302-692 (H-10 5
WDL-V317 1 1/2" 1 1/2"
~
2" TO WOL-T-4 t
3" 302-693 (H-8)
~ li!S' U
V>Z
=>
=>O z
I= 0~
8T;._::J ZV>~
WDL-P-96 1"
1/2" 2"
2" NEUTRALIZER PUMPS 4
I
- I 11/4"
+
11" 3"
1 1/2" 1 1/2" 1 1/2" LT ATMOS.
124 }ATMOS.
NEUTRALIZER FEED TANK 2"
NEUTRALIZED WASTE STORAGE TANK WDL-T-9 WDL-T-10 2"
2" 1 1/2" 1 1/2" 2"
--t~
WDL-V147 WDL-V149
- 2" 302-003 COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM NO, DWG. NO.
TillE REFERENCES 3
y y
2 3*
1 1/2" Vv0L-V250 1 1/2" 1" NaOH 1/2" H2S04 NOTES:
FROM MU-KlA,18 302-660 (F-10 FROM WDL-P-7A/B 302-690 ( A-3)
FROM WDL-V158 THIS DWG (B-6 CAUSTIC MIX FROM CA-V158 302-670 (D-8)
NEUTRALIZING ACID PUMP 302-162 {C-8 FROM WT-V152
- 1. VALVE POSITION SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
- 3. SET POINT VALUES FOR REUEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
- 4. ALL PIPING ON THIS DRAWING IS ~
- 5. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N-3 UNLESS NOTED.
- 6. SEISMIC CLASS S-11 UNLESS NOTED.
- 7. ALL DRAINS AND LOCAL SAMPLES AFTER LAST VALVE SHALL BE S-111 NON-NUCLEAR.
- 8. A DENOTES THAT NO SCHEMATIC EXISTS THEREFORE THE PHYSICAL DRAWING IS FLAGGED.
- 9. FOR REFERENCES SEE DRAWING.302-690.
- 10. VALVE INTERNALS FOR WDL-V365 REMOVED.
E D
c
~
0 I Cad Fila Name : 30269LR9
===---1 Im THIS JS A COMPUTER GENERATED DRA'NING 00 NOT REVISE IT MANUALLY ExeJsJ!~
LIQUiD WASTE DISPOSAL FLOW DIAGRAM PRECOAT FILTER, CATION &: DEBORATING DEMINERAUZER. LAUNDRY, NEUlRAUZATION TMl-1 302-691 NONE 9
~1 I A
I I
_ _____________________ _J
7 8
I I
- H I
I I
IG I
I I
FROM DH-Y52 302-640 (H-5 FROM SF-V40 302-630 (C-2 SPENT FUEL COOLING SYSTEM ITI*HS DWG (F-7 FROM WOL-V47,48 TI-US DWG (C 8 3"
~21/2" 302-690 (E-2)
FROM WDL-V70,71 3"
THIS DWG (o-a*
t.2"~
WOL-V386~
2 1/2a I
©
~85
"'L-V279 T-- E'T' Alif I
EVENT 3"
(3~~.';~(;=~ I 3" 1~~~~
FROM WDL-P-7A~ 1 1/2a 302-690 (8-3" 3"
1 1/2" 3"
6 3"
WDL-V40 2 1/2" 3"
3" 12 1/2" 3"
I 5
2" DRAIN HOR. PT-6 302-690 (D-8' WDL-V387 1/2" t~~
302-669 2"
PRECOAT FILTER WDL-F-16 3"
2 1 VENT HOR. PT-5 302 690 (C 7) 1 1/2" q').P r 3"
'* '"". fG ~'WDL-V278
~
I WDL-V284 1/4"
~*
,5 3"
302-692 {H-7 Fl-137 1 1/4" 2"
DEBORAT!NG DEMlNERALIZER WDL-K-1A WDL-V204 2,, SAMPLE 3
2 1/2" 2"
1/2" er..
11 112;.
2 WDL-V203 REVISIONS REV I ZONE 9 I VARESI REVISED TO INCORPORATE ECR-14-00032 REV. 2 WDL-V7
-1"-Q)
AIR SUPPLY
~,~
.. gii 12* I 1*
11~
DEBORATING DEMINERALIZER WDL-K-16 WDL-V205
~
~N~
TAGGED VALVE SOLENOID HOOK-UP FOR VALVES MARKED "'
V.-OL-V209 1 1/4" SEE 302-671 AREA G-4 2"
SAMPLE TO WDL-VlO 302-692 (C-1 O)_
H G
1 1/4"
~gt r-... u.,..-
I.
.. i I.
Y 2..
2 n~
F 2 1/2" I
.\\.V,, 2f _, '
3" (SEE NOTE 10) I 11-lXJ'-"-li I
1 3"
~
~--------~*----~...... ~!
WOL-V69 F
I I
E D
le I
I I
B A
L __
2 1/2" 3"
11/2"~
WDL-V432 VENT HDR. PT.5 302-690 (D-7 1HIS DWG ( C-8)
SEE 302-671 AREA G-2 TO WDL-T-4
(}02-693 Qi=BLJ-1HIS DWG (F-8)
TO WDL-V52 THIS DWG (G-8)
TO WDL-V363 302-692 (F-10)
FROM WDL-V434 THIS DWG (E-8 t/2" 1/2" 2" I 2" 1 1/2" S-11 S-11 2*
1 1/2" I
I CATION DEMINERALIZER WDL-K-2A 2"
WDL-V213 WDL-V215 WDL-V733 3"
3" 2"
1 1/2° NON-NU, N-3 RECLAIMED WATER a
I 302 669 (E 3) )
1 1/ 2
- 4 1 1/2" WDL-V318 IFROM FLOOR DRAINS ~
ATMOS.
1 1/2" 3*
4" LAUNDRY ~~ir:: STORAGE I I 2"
D 1 1 /2" I
y WDL-V155 8
WDL-T-12 2*
T WDL-V678 y
WDL-P-15 LAUNDRY WASTE PUMP 7
WOL-V192 WDL-V350 WDL-V159
~
T "2:V
, 1/2" WDL-V156 2 1/2" WDL-V46
-1 h 1/2" 2 1/2" 3"
WDL-V41 2 1/2" 1 1/2" 1 1/2" 2" 12
1/2" L___/FE\\
~
1 1/2" 1 1/2" 3"
WDL-V157*
6 2"
WDL-V67 1/2" WDL-V271 CATION 1 lli 2"
I I DEMINERALIZER
~
WDL-K-26 2"
1 1/2" 2"
WDL-V214 RECLAIMED WATER 302-669 {E-3) 1 1/2°
-,_'u I o:::J V> zZ Ji WDL-V316 WDL-V190 I.
1/2" WOL-~
r.V V153 I. U y
1 1/2"
~
~
1 1/2" 1 1/2" 1 1/2" 1 1/2" Vv0L-V151 WDL-V366 TO MISC WASTE EVAP.
302-692 (H-10 5
WDL-V317 1 1/2" 1 1/2"
~
2" TO WOL-T-4 t
3" 302-693 (H-8)
~ li!S' U
V>Z
=>
=>O z
I= 0~
8T;._::J ZV>~
WDL-P-96 1"
1/2" 2"
2" NEUTRALIZER PUMPS 4
I
- I 11/4"
+
11" 3"
1 1/2" 1 1/2" 1 1/2" LT ATMOS.
124 }ATMOS.
NEUTRALIZER FEED TANK 2"
NEUTRALIZED WASTE STORAGE TANK WDL-T-9 WDL-T-10 2"
2" 1 1/2" 1 1/2" 2"
--t~
WDL-V147 WDL-V149
- 2" 302-003 COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM NO, DWG. NO.
TillE REFERENCES 3
y y
2 3*
1 1/2" Vv0L-V250 1 1/2" 1" NaOH 1/2" H2S04 NOTES:
FROM MU-KlA,18 302-660 (F-10 FROM WDL-P-7A/B 302-690 ( A-3)
FROM WDL-V158 THIS DWG (B-6 CAUSTIC MIX FROM CA-V158 302-670 (D-8)
NEUTRALIZING ACID PUMP 302-162 {C-8 FROM WT-V152
- 1. VALVE POSITION SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
- 3. SET POINT VALUES FOR REUEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
- 4. ALL PIPING ON THIS DRAWING IS ~
- 5. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N-3 UNLESS NOTED.
- 6. SEISMIC CLASS S-11 UNLESS NOTED.
- 7. ALL DRAINS AND LOCAL SAMPLES AFTER LAST VALVE SHALL BE S-111 NON-NUCLEAR.
- 8. A DENOTES THAT NO SCHEMATIC EXISTS THEREFORE THE PHYSICAL DRAWING IS FLAGGED.
- 9. FOR REFERENCES SEE DRAWING.302-690.
- 10. VALVE INTERNALS FOR WDL-V365 REMOVED.
E D
c
~
0 I Cad Fila Name : 30269LR9
===---1 Im THIS JS A COMPUTER GENERATED DRA'NING 00 NOT REVISE IT MANUALLY ExeJsJ!~
LIQUiD WASTE DISPOSAL FLOW DIAGRAM PRECOAT FILTER, CATION &: DEBORATING DEMINERAUZER. LAUNDRY, NEUlRAUZATION TMl-1 302-691 NONE 9
~1 I A
I I
_ _____________________ _J