ML16130A322
| ML16130A322 | |
| Person / Time | |
|---|---|
| Site: | Crane (DPR-050) |
| Issue date: | 04/11/2016 |
| From: | Exelon Generation Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16127A520 | List:
|
| References | |
| TMI-16-035 | |
| Download: ML16130A322 (1) | |
Text
- H IG I
I I
F I
IE I
jo I
I I
I lc I
I
!s I
I lA I
I I
I I
I I
I 8
FROM IA-V92 3/4" OD 302 275 (F 6)
~
13/8" OD 13/8" OD IA-V2080 IA-V2081 FIELD t
Y. h" on '
SPARE IA-V2079 CE-260
~
CONTROL PANEL (SODIUM ANALYZER) 7 AS-V2 6
5 C-l--r150-1 I 3/8"
\\ ____..........
~::)I.... I(:J<Jo*.. sojEE~~G~~rE~A "A"
1/4" DO IA-V1047 TO HT-SV-18 BOILER IGNITER "B"
1/2" OD TL-V4 3/8" OD TO LOUVERS EAST SIDE T.B.EL 305'-0" 4
IA-V2084 IA-V1059 11 IA-V1060 IA-V1061 3/8" 3/8" 3
2 REVISIONS 10 IA-6,7]REVISED TO INCORPORATE ECR-10-00290 REV. 1 IA-V2086 IA-V2082 IA-V2085 1/4" J/B" IA-V1064 IA-V1066 314..
POINT #l THIS DWG (D 8) 3/8" IA-F-8 A/B INSTRUMENT AIR FILTERS IA-V2083 IA-V1065 1/4" PI 1402 IA-V1068 3/8" IA-V1069 POINT #2 THIS DWG (F 8) 3/8" IA-V1045 150-1 IC-1 POINT #2 3/8" THIS DWG
~
I lfL uu 1/2" 00
~WB-2 AIR INLET 10 cBL:
D I
I I
I I
I I
~6~e~~~~~s~*
POINT #1 THIS DWG (G 1)
FROM IA-VBB 302 275 (F 5) 8 T. BLDG TO FORCED DRAFT FAN "A" INLET DAMPER 150-1 ~C-1
/C" 5/8" OD
.:-;u 4
IA-V1058 1/4" OD TO AS-LT-18 (AUX BOILER "A" DRUM) 1/2" OD 1/4" OD FO-V30A
/C" WfV V'-'
5/8" OD IA-V1049 TO C-1 TO AUX BOILER AUX STEAM A & B PRESSURE CONTROL PANEL TRANSMITTER 1/4" OD *;
3/8" OD 1/4" 00 1/4" 00 3/8" 00 1/2" 00
~
z ~
=> "' ~
~
d ~
oc
~.,
r:2 [::::..r
<00 N
~ I
~ N 8 g ~
CW-V2A 1/2" 00 TO SLMS 302.304 SH. 2 (D 7) 7 10 6
1/4" OD DEAD ENDED
@ HD-V6 T. BLDG 3/8" OD IA-V1048 1/4" DO 3/8" OD t
CW-V2B AUX BOILER "A"
(EAST END)
AUX BOILER "a"
(EAST END)
TO AS-LT-20 (AUX BOILER "8" DRUM) 5 1/2" 00 1/4" 00 IA-V1055 WB-1 AIR INLET DAMPER "A" AUX BOILER 1/2" 00 C-12A
~~~
OUTLET DAMP,~~
~
AUX BOILER A
AS-V21A F"
lj'T vu 1/4" OD IA-V1042 1/2" 00 1/4" DO C-12B OUTLET DAMPER AUX BOILER "B" AS-V21B IA-V1043 r
vu T
1/2" 00 FO-V308 TO AS-FT -5 (AUX BOILER "A" STEAM FLOW)
TO IA-V1041 1 TO FW-1B-1 FW-18-2
~~ IA-V2248 IA-V1044 1/4" DO TO AS-FT-6 (AUX BOILER "B" STEAM FLOW)
.. t 1/4" OD
. t
"~
DEAD ENDED TO SWITCHES CW-DPS-498 A & B (AMERTAP b.P)
SEE NOTE 4 IA-V10288 3/8" 00 1/2" OD 3/4" OD 1/4" OD 3/4" OD TO AS-PC-668 (IWT CAUSTIC HEATER STM)
TO IWT CONTROL PANEL 302-308 (B-8 TO EXHAUST HOOD TEMP TRANSMITTERS 3/8" 00 HS-TT-1293 & HS-TT-1294 NOTES 1/4" OD
- 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGN A TOR UNLESS OTHERWISE NOTED.
- 3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.
- 4. X-CONNECT TO C.W. SYSTEM. ASSURE PROPER ISOLATION PRIOR TO DEPRESSURIZING I.A. SYSTEM.
4 3/8" 00 302-003 302-002 302-001
. t 3/4" OD FROM IA-V84 302-275 (F-2)
TO SC-TC-3 (GENERATOR HYDROGEN COOLERS)
COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM I nv I vnv... v.
I 3
2 IA-V1071 T~A~o~~.~~NE~~FT T. BLDG --L OUTSIDE DAMPER Cad File Name :302277_54_R10 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon.
~
"'7fi:::r
~
Nuclear INSTRUMENT AIR FLOW DIAGRAM TURBINE BUILDING END USERS 302277 I 4 SCALE: N/A L ______________________________________________________________________________________________________________________________ _
10 H
G F
E D
c
~
A
- H IG I
I I
F I
IE I
jo I
I I
I lc I
I
!s I
I lA I
I I
I I
I I
I 8
FROM IA-V92 3/4" OD 302 275 (F 6)
~
13/8" OD 13/8" OD IA-V2080 IA-V2081 FIELD t
Y. h" on '
SPARE IA-V2079 CE-260
~
CONTROL PANEL (SODIUM ANALYZER) 7 AS-V2 6
5 C-l--r150-1 I 3/8"
\\ ____..........
~::)I.... I(:J<Jo*.. sojEE~~G~~rE~A "A"
1/4" DO IA-V1047 TO HT-SV-18 BOILER IGNITER "B"
1/2" OD TL-V4 3/8" OD TO LOUVERS EAST SIDE T.B.EL 305'-0" 4
IA-V2084 IA-V1059 11 IA-V1060 IA-V1061 3/8" 3/8" 3
2 REVISIONS 10 IA-6,7]REVISED TO INCORPORATE ECR-10-00290 REV. 1 IA-V2086 IA-V2082 IA-V2085 1/4" J/B" IA-V1064 IA-V1066 314..
POINT #l THIS DWG (D 8) 3/8" IA-F-8 A/B INSTRUMENT AIR FILTERS IA-V2083 IA-V1065 1/4" PI 1402 IA-V1068 3/8" IA-V1069 POINT #2 THIS DWG (F 8) 3/8" IA-V1045 150-1 IC-1 POINT #2 3/8" THIS DWG
~
I lfL uu 1/2" 00
~WB-2 AIR INLET 10 cBL:
D I
I I
I I
I I
~6~e~~~~~s~*
POINT #1 THIS DWG (G 1)
FROM IA-VBB 302 275 (F 5) 8 T. BLDG TO FORCED DRAFT FAN "A" INLET DAMPER 150-1 ~C-1
/C" 5/8" OD
.:-;u 4
IA-V1058 1/4" OD TO AS-LT-18 (AUX BOILER "A" DRUM) 1/2" OD 1/4" OD FO-V30A
/C" WfV V'-'
5/8" OD IA-V1049 TO C-1 TO AUX BOILER AUX STEAM A & B PRESSURE CONTROL PANEL TRANSMITTER 1/4" OD *;
3/8" OD 1/4" 00 1/4" 00 3/8" 00 1/2" 00
~
z ~
=> "' ~
~
d ~
oc
~.,
r:2 [::::..r
<00 N
~ I
~ N 8 g ~
CW-V2A 1/2" 00 TO SLMS 302.304 SH. 2 (D 7) 7 10 6
1/4" OD DEAD ENDED
@ HD-V6 T. BLDG 3/8" OD IA-V1048 1/4" DO 3/8" OD t
CW-V2B AUX BOILER "A"
(EAST END)
AUX BOILER "a"
(EAST END)
TO AS-LT-20 (AUX BOILER "8" DRUM) 5 1/2" 00 1/4" 00 IA-V1055 WB-1 AIR INLET DAMPER "A" AUX BOILER 1/2" 00 C-12A
~~~
OUTLET DAMP,~~
~
AUX BOILER A
AS-V21A F"
lj'T vu 1/4" OD IA-V1042 1/2" 00 1/4" DO C-12B OUTLET DAMPER AUX BOILER "B" AS-V21B IA-V1043 r
vu T
1/2" 00 FO-V308 TO AS-FT -5 (AUX BOILER "A" STEAM FLOW)
TO IA-V1041 1 TO FW-1B-1 FW-18-2
~~ IA-V2248 IA-V1044 1/4" DO TO AS-FT-6 (AUX BOILER "B" STEAM FLOW)
.. t 1/4" OD
. t
"~
DEAD ENDED TO SWITCHES CW-DPS-498 A & B (AMERTAP b.P)
SEE NOTE 4 IA-V10288 3/8" 00 1/2" OD 3/4" OD 1/4" OD 3/4" OD TO AS-PC-668 (IWT CAUSTIC HEATER STM)
TO IWT CONTROL PANEL 302-308 (B-8 TO EXHAUST HOOD TEMP TRANSMITTERS 3/8" 00 HS-TT-1293 & HS-TT-1294 NOTES 1/4" OD
- 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGN A TOR UNLESS OTHERWISE NOTED.
- 3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.
- 4. X-CONNECT TO C.W. SYSTEM. ASSURE PROPER ISOLATION PRIOR TO DEPRESSURIZING I.A. SYSTEM.
4 3/8" 00 302-003 302-002 302-001
. t 3/4" OD FROM IA-V84 302-275 (F-2)
TO SC-TC-3 (GENERATOR HYDROGEN COOLERS)
COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM I nv I vnv... v.
I 3
2 IA-V1071 T~A~o~~.~~NE~~FT T. BLDG --L OUTSIDE DAMPER Cad File Name :302277_54_R10 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon.
~
"'7fi:::r
~
Nuclear INSTRUMENT AIR FLOW DIAGRAM TURBINE BUILDING END USERS 302277 I 4 SCALE: N/A L ______________________________________________________________________________________________________________________________ _
10 H
G F
E D
c
~
A