IG I
!F I
'E I
I I
I iD I
Ie
!e
~
A L
302-172 (H-B SEALB~~~~U~UPLY FROW OW-V62 302 163(A 6 8
2" VENT ~
OW-V61 2 1/2" 1/2" 7
6 GP15::J GP150-1 B"
5 2"
CO-Y-l GP150-2 I BY I
GRAVER lIB" I' 1--------11"-'
"A" RECOVERY COMPARTMENT 4
3 OVERFLOW 3"
DECANT
@ -I------@-----§ 2"
~ __ @- _____,
(CO-T-7A)
I
~-----
I I
1.. - SPARE DRAIN 3"
B"
~
CO-V314 CO-V303 1
1 ' "
/
DRIP BASIN 2"
--r--...J I
I I
I I
I I
TO PRECOAT 4"
C?_tl~
iT ;,--------
CO-11818 I
I I
I I
I I
I I
I I
I 11/'"
if]
1 "I' 16~
Co-V340A
~
CO-V395
£2" TO BACKWASH RECOVERY 302 172 (C t
~-2 8"
3/4" VENT 3/4" VENT 1" VENT
,r"30Y52=69"3"("'G=-8R\\,1 4" TO SPENT RESIN STORAGE TO CO-V363 302-172 (C-6 TO BACKWASH RECOVERY 8"
CO-V307' LJ 8
8" CO-V224.CO-V222 CO-V214 L.C.
4" CO-V211
," VENT y
4" 6"
"1 llm~ ~e:"*_ ~
~ It
~...
1092 CO-V306 I
CO-V94A nR GPl50-1 I 7
SUMP RECYCLE 4"
1/2" O"'~
's-0"
<0
'S-
°'7
~J~g~~.
CO-V387
~~
"'~
~~
x"
~U; 09
"-iJi
~
@-i I
6SH'L I
~-[
I
~I
~I I
~I
~L 12" POWDEX (SPENTRESiN)
SUMP 2"
1/2" 6
TA" CQ-V315 cb ~~
v.-
- <3," OP150-1 j GP150-2 OZ N >-0 N woo o
~'"
~'"
5 1 1/2" DEWATERING PUMP
~
1/2" I
I I
I
~l 3/4"
~~
I I
I I
I I
I I
I I
I 1 112ft 2?ic?
i---~----
CO-V326 I FI I
1095 I
I I
I
1 I
I I
I I
I
':;~9) GRAB l...[l3,l4" SAMPLE WI CO-V327 1 1/2" CO-V337.
I!:J-L-D "RDP" 1 1/2" 3
4" 3"
OR.'
I I
I
~
I PHASE SEPilRilTOR PUMPS FS 1087 I
I I
I I
L 2
REVlSIONS REVISED TO INCORPORATE ECR-09-00103 REV.
-~
~~~ ------~
I I
I PHASE SEPARATOR (CO-T-5) c?
DRIP BASIN I
I I
I I
I I
I NOTES:
I I
~~
I I
I 2"
- 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED
--l H
G F
E o
c
°1
~
9i I_~"_'O~'
I~
~I I
G~~~R~TtD ~~~~~~R DO
~
NOT REVISE IT MANUALLY AmerGen MAR< TElKO,""
03/04/09 POWDEX WASTE PROCESSING
"~---"--;?,/.10',
AND DRUMMING SYSTEM A
FLOW DIAGRAM 302-106 N/AnvS SCAlE: -NlA---
2
~
IG I
!F I
'E I
I I
I iD I
Ie
!e
~
A L
302-172 (H-B SEALB~~~~U~UPLY FROW OW-V62 302 163(A 6 8
2" VENT ~
OW-V61 2 1/2" 1/2" 7
6 GP15::J GP150-1 B"
5 2"
CO-Y-l GP150-2 I BY I
GRAVER lIB" I' 1--------11"-'
"A" RECOVERY COMPARTMENT 4
3 OVERFLOW 3"
DECANT
@ -I------@-----§ 2"
~ __ @- _____,
(CO-T-7A)
I
~-----
I I
1.. - SPARE DRAIN 3"
B"
~
CO-V314 CO-V303 1
1 ' "
/
DRIP BASIN 2"
--r--...J I
I I
I I
I I
TO PRECOAT 4"
C?_tl~
iT ;,--------
CO-11818 I
I I
I I
I I
I I
I I
I 11/'"
if]
1 "I' 16~
Co-V340A
~
CO-V395
£2" TO BACKWASH RECOVERY 302 172 (C t
~-2 8"
3/4" VENT 3/4" VENT 1" VENT
,r"30Y52=69"3"("'G=-8R\\,1 4" TO SPENT RESIN STORAGE TO CO-V363 302-172 (C-6 TO BACKWASH RECOVERY 8"
CO-V307' LJ 8
8" CO-V224.CO-V222 CO-V214 L.C.
4" CO-V211
," VENT y
4" 6"
"1 llm~ ~e:"*_ ~
~ It
~...
1092 CO-V306 I
CO-V94A nR GPl50-1 I 7
SUMP RECYCLE 4"
1/2" O"'~
's-0"
<0
'S-
°'7
~J~g~~.
CO-V387
~~
"'~
~~
x"
~U; 09
"-iJi
~
@-i I
6SH'L I
~-[
I
~I
~I I
~I
~L 12" POWDEX (SPENTRESiN)
SUMP 2"
1/2" 6
TA" CQ-V315 cb ~~
v.-
- <3," OP150-1 j GP150-2 OZ N >-0 N woo o
~'"
~'"
5 1 1/2" DEWATERING PUMP
~
1/2" I
I I
I
~l 3/4"
~~
I I
I I
I I
I I
I I
I 1 112ft 2?ic?
i---~----
CO-V326 I FI I
1095 I
I I
I
1 I
I I
I I
I
':;~9) GRAB l...[l3,l4" SAMPLE WI CO-V327 1 1/2" CO-V337.
I!:J-L-D "RDP" 1 1/2" 3
4" 3"
OR.'
I I
I
~
I PHASE SEPilRilTOR PUMPS FS 1087 I
I I
I I
L 2
REVlSIONS REVISED TO INCORPORATE ECR-09-00103 REV.
-~
~~~ ------~
I I
I PHASE SEPARATOR (CO-T-5) c?
DRIP BASIN I
I I
I I
I I
I NOTES:
I I
~~
I I
I 2"
- 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.
ACTUAL POSITIONS CONTROLLED BY PROCEDURES
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED
--l H
G F
E o
c
°1
~
9i I_~"_'O~'
I~
~I I
G~~~R~TtD ~~~~~~R DO
~
NOT REVISE IT MANUALLY AmerGen MAR< TElKO,""
03/04/09 POWDEX WASTE PROCESSING
"~---"--;?,/.10',
AND DRUMMING SYSTEM A
FLOW DIAGRAM 302-106 N/AnvS SCAlE: -NlA---
2
~