ML16130A280

From kanterella
Jump to navigation Jump to search
302051, Sheet Na, Rev 061, Auxiliary Steam Flow Diagram
ML16130A280
Person / Time
Site: Crane 
(DPR-050)
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16130A280 (1)


Text

I I

H G

E D

c B

10 9

8 7

6 5

4 3

2 1-91 r--------------------------------------~----------------------------~----------------------------~----------------------------~----------------------------~----------------------------~----~====;=:=:=:=:==::=:=:=~~======:===z~~s~~~~----~------------------~

H h

H H

M AUTO/MAN.

'"- '"e J

A C'T'T'""'

2 1/2" 3"

3" TO AS-V4 302-011 (E-4)

TO AS-Y5B 3~

TO AS V5A 302 011 (D 8) 302-042 (D-8 TO GS-V7 302-141 (B-6) 302 121 (C 2)

("Z")

DEMIN. WATER 302-163 (C-1 AS-V75A TO EMERGENCY FEED PUMP TO MAIN FEED PUMP "B" TO MAIN FEED PUMP "A" 10" CH'EM.

CLEANING F.C.

8" 12"

$-V1A FW-J4A L.P.HEATER A 2"

~

~

    • ~

rn

'?

AS-V78B

~ ~ ~ e (3/4" 1........,

"-~

r<)

j 1/2" ::;- ~~

I ~

I u c AS-V79A

~

3" 1 ~

AS-V798 1/2" TO CA-V383 AREA C-2)

~I,

~~I t.;tN

~~

~~

AUXILIARY BOILER 1 A AS-B-1A LS (SEE 302-669- - ~ =-

l-..l.----------------------------------------,;:3_" -----:=='__J ; ----- -

200 1"

TO WOL-V321 ~

3" 1"

TO WOL-V322 ( 302 692 (D 10) 1" TOWDL-V323~

TO WDL-V324 ( 302 692 (D 2) 1" AS-V93 AS-ST-39 3/4" 12" 1"

~ 3/4"

~

("Y') TO AS-V65 302121 (E 2) ~

AS-V101B 12" 6"

6" AS-V59B AS-V213B AUXILIARY BOILER 302-052 (D-8 302-175 (D-8)

FROM AUX. BOILER CHEMICAL PUMPS 302 175 (D 8) 1" 12" 12" y

8" AS-V~1B 10" CHEM.

CLEANING 6"

6"

,1" 61 10-6 ReVISED TO INCORPORATe ECR 12-00164 REV. o H

~-

TO FW-J4B 16" 302 042 (D 5)

FROM CONDENSATE STORAGE TANKS CO-T-1A & CO-T-18 302-101 (H-5 FUEL OIL 302283(C2)(C2 I

AS-V168A/B

~I Ql VENT

~' 6i 1/2"0.D.

FUEL OIL 302-283(0-2}(8-21 A/PI l:~

LAS 1/4" AS-V178A/B AS-V1108A/B,114..

AS-V176A/B

  • DRAIN

/T

~

I () ~fi~g~

1/4" FUEL OIL 302-283(D-2)i_C-2)

.AS-V180A/B _6AS-V1109A/B 114" 1 1/4"

~VfA~~bL$~M 1 112" 3/4" (i~s)R;:-B-1A i~ ~g=~?

(A-4) AS-8-18 FOR AUX. BLR.

ATOMIZING STM.

l 1 12.. SEE DET.(D-3)

AS-V163A/B 3/4" AUXILIARY BOILER ATOMIZING STEAM (TYP. FOR AS B 1A & AS B 18)

  • B&W SUPPLIED ITEMS NOTES
1. VALVE POSITlONS SHOWN FOR REFERENCE <JNL Y.

ACTUAL POSITIONS DETERMINED BY PROCEDURES.

G F

E D

c AS-V25B

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED TO AUX.BOILER 1 1 /2" I ~~~W~~~(E:7~K
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE.
4. FOR PNEUMATIC DETAILS SEE GAl OWG. SS-308-407.
5. HOSES ARE NORMALLY DISCONNECTED AND HEATERS ARE OUT OF SERVICE UNLESS AUX BOILER IS UNAVAILABLE.
6. VALVE INTERNALS HAVE BEEN REMOVED

~

ICodFIIeNorne, J02051 R61 16

~

Exelon.

~

AUXILIARY STEAM Lh AS VB5 A> vn"'

)

~ms 1

(T)

"'f AS yg 4

~ ~

MISC. DRAIN

~

3 302 003 COMPONENT & SYS ID INDEX

.,.~:*

TANK CO T 2 2

302 002 SYMBOLS INSTRUMENTATION 1"

2 302 102 (G 6) 302 001 SYMBOLS FLOW DIAGRAM NO.

DWG. NO Tlll_E REFERENGES 5

4 3

2 10 9

8 7

6

I I

H G

E D

c B

10 9

8 7

6 5

4 3

2 1-91 r--------------------------------------~----------------------------~----------------------------~----------------------------~----------------------------~----------------------------~----~====;=:=:=:=:==::=:=:=~~======:===z~~s~~~~----~------------------~

H h

H H

M AUTO/MAN.

'"- '"e J

A C'T'T'""'

2 1/2" 3"

3" TO AS-V4 302-011 (E-4)

TO AS-Y5B 3~

TO AS V5A 302 011 (D 8) 302-042 (D-8 TO GS-V7 302-141 (B-6) 302 121 (C 2)

("Z")

DEMIN. WATER 302-163 (C-1 AS-V75A TO EMERGENCY FEED PUMP TO MAIN FEED PUMP "B" TO MAIN FEED PUMP "A" 10" CH'EM.

CLEANING F.C.

8" 12"

$-V1A FW-J4A L.P.HEATER A 2"

~

~

    • ~

rn

'?

AS-V78B

~ ~ ~ e (3/4" 1........,

"-~

r<)

j 1/2" ::;- ~~

I ~

I u c AS-V79A

~

3" 1 ~

AS-V798 1/2" TO CA-V383 AREA C-2)

~I,

~~I t.;tN

~~

~~

AUXILIARY BOILER 1 A AS-B-1A LS (SEE 302-669- - ~ =-

l-..l.----------------------------------------,;:3_" -----:=='__J ; ----- -

200 1"

TO WOL-V321 ~

3" 1"

TO WOL-V322 ( 302 692 (D 10) 1" TOWDL-V323~

TO WDL-V324 ( 302 692 (D 2) 1" AS-V93 AS-ST-39 3/4" 12" 1"

~ 3/4"

~

("Y') TO AS-V65 302121 (E 2) ~

AS-V101B 12" 6"

6" AS-V59B AS-V213B AUXILIARY BOILER 302-052 (D-8 302-175 (D-8)

FROM AUX. BOILER CHEMICAL PUMPS 302 175 (D 8) 1" 12" 12" y

8" AS-V~1B 10" CHEM.

CLEANING 6"

6"

,1" 61 10-6 ReVISED TO INCORPORATe ECR 12-00164 REV. o H

~-

TO FW-J4B 16" 302 042 (D 5)

FROM CONDENSATE STORAGE TANKS CO-T-1A & CO-T-18 302-101 (H-5 FUEL OIL 302283(C2)(C2 I

AS-V168A/B

~I Ql VENT

~' 6i 1/2"0.D.

FUEL OIL 302-283(0-2}(8-21 A/PI l:~

LAS 1/4" AS-V178A/B AS-V1108A/B,114..

AS-V176A/B

  • DRAIN

/T

~

I () ~fi~g~

1/4" FUEL OIL 302-283(D-2)i_C-2)

.AS-V180A/B _6AS-V1109A/B 114" 1 1/4"

~VfA~~bL$~M 1 112" 3/4" (i~s)R;:-B-1A i~ ~g=~?

(A-4) AS-8-18 FOR AUX. BLR.

ATOMIZING STM.

l 1 12.. SEE DET.(D-3)

AS-V163A/B 3/4" AUXILIARY BOILER ATOMIZING STEAM (TYP. FOR AS B 1A & AS B 18)

  • B&W SUPPLIED ITEMS NOTES
1. VALVE POSITlONS SHOWN FOR REFERENCE <JNL Y.

ACTUAL POSITIONS DETERMINED BY PROCEDURES.

G F

E D

c AS-V25B

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED TO AUX.BOILER 1 1 /2" I ~~~W~~~(E:7~K
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE.
4. FOR PNEUMATIC DETAILS SEE GAl OWG. SS-308-407.
5. HOSES ARE NORMALLY DISCONNECTED AND HEATERS ARE OUT OF SERVICE UNLESS AUX BOILER IS UNAVAILABLE.
6. VALVE INTERNALS HAVE BEEN REMOVED

~

ICodFIIeNorne, J02051 R61 16

~

Exelon.

~

AUXILIARY STEAM Lh AS VB5 A> vn"'

)

~ms 1

(T)

"'f AS yg 4

~ ~

MISC. DRAIN

~

3 302 003 COMPONENT & SYS ID INDEX

.,.~:*

TANK CO T 2 2

302 002 SYMBOLS INSTRUMENTATION 1"

2 302 102 (G 6) 302 001 SYMBOLS FLOW DIAGRAM NO.

DWG. NO Tlll_E REFERENGES 5

4 3

2 10 9

8 7

6