ATTACHMENT 3-5O APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air Rev. 27 DECAY HEAT RIVER WATER A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
DR-P-1A X
X X
P X
S X
X X
X Train A DR-P-1B X
X X
X P
X X
R S
D R
S D
R S
D Train B DR-S-1A S
S S
S S
S S
S S
Train A DR-S-1B S
S S
S S
S Train B DR-V-1A X
X X
S S
X X
X Train A DR-V-1B X
X X
X P
X S
R S
D R
S D
R S
D Train B
ATTACHMENT 3-5O APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air Rev. 27 DECAY HEAT RIVER WATER A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
DR-P-1A X
X X
P X
S X
X X
X Train A DR-P-1B X
X X
X P
X X
R S
D R
S D
R S
D Train B DR-S-1A S
S S
S S
S S
S S
Train A DR-S-1B S
S S
S S
S Train B DR-V-1A X
X X
S S
X X
X Train A DR-V-1B X
X X
X P
X S
R S
D R
S D
R S
D Train B
ATTACHMENT 3-5O APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air Rev. 27 7DECAY HEAT RIVER WATER D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T G
G H
H H
H H
H B
B B
B B
B B
B S
S S
S B
B B
B B
B B
B P
P P
P F
F F
F F
F F
F F
F F
F F
F F
F H
H H
H F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 DR-P-1A S
X X
X R
Train A DR-P-1B S
P X
X R
X Train B DR-S-1A S
S S
X Train A DR-S-1B S
S S
X Train B DR-V-1A S
X X
X M
Train A DR-V-1B S
P X
X M
X Train B
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
NI-11 X
X P
S X
X X
X Train A NI-12 S
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD RC4A-TE-1 S
X S
X X
X X
Train X RC4A-TE-4 S
S S
X X
X Train X RC4B-TE-1 S
X S
S X
X X
Train X RC4B-TE-4 S
S S
X X
Train X RC-TE-958 S
X X
X X
X X
R S
D R
S D
Train A - Control Room & RSD RC-TE-960 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD RC5A-TE-2 S
X S
S X
X X
Train X RC5A-TE-4 S
S S
X X
Train X RC5B-TE-2 S
X S
S X
X X
X Train X RC5B-TE-4 S
S X
X X
Train X RC-TE-959 S
X X
X X
X X
R S
D R
S D
Train A - Control Room & RSD RC-TE-961 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD RC3A-PT3 S
X P
X X
X P
X X
X Train A RC-PT-963 S
X X
X X
X X
X R
S D
R S
D Train A - RSD Only RC-PT-949 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 2a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
RC1-LT-1 S
D S
S X
X X
Train X RC1-LT-3 S
D S
S S
X X
X X
Train X RC-LT-777 X
X X
R S
D R
S D
R S
D Train B - Control Room & RSD RC2-TE-1 S
S S
X X
Train X RC2-TE-2 X
X X
R S
D R
S D
R S
D Train B FW-LT-775 S
X P
P X
X X
R S
D R
S D
Train A - Control Room & RSD FW-LT-789 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD FW-LT-788 S
X X
X X
X X
R S
D R
S D
Train A - Control Room & RSD FW-LT-776 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD SP6A-PT-1 S
S S
X X
X Train X - Also for MS-V-3D, E, F SP6A-PT-2 S
S S
S X
X X
Train X - Also for MS-V-3D, E, F MS-PT-950 S
X P
P X
X X
R S
D R
S D
Train A - Control Room & RSD MS-PT-1180 S
X X
X Train B SP6B-PT-1 S
S S
S X
X X
Train X - Also for MS-V-3A, B, C SP6B-PT-2 S
S S
X X
X Train X - Also for MS-V-3A, B, C MS-PT-951 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 3a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
MS-PT-1184 S
S S
X X
X X
Train A DH-DPT-802 X
X X
S X
X X
X X
X R
S D
R S
D Train A - Control Room & RSD DH-DPT-803 X
X X
S X
X X
R S
D R
S D
Train B - Control Room & RSD DH-FI-299A Train A - Local Indication DH-FI-299B Train B - Local Indication DH2-TE-1 X
X X
S X
X X
X X
X R
S D
R S
D Train A - Control Room & RSD DH2-TE-2 X
X X
S X
S X
S X
R S
D R
S D
R S
D Train B - Control Room & RSD DH6-TE-1 X
X X
S X
X X
X X
X R
S D
R S
D Train A - Control Room & RSD DH6-TE-2 X
X X
S X
S X
S X
R S
D R
S D
R S
D Train B - Control Room & RSD CO-LI-1004 Local Indication CO-LI-1005 Local Indication MU14-LT X
S X
S S
X X
X Train X MU-LT-778 X
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD DH-LT-808 P
X S
X X
X X
X X
X X
Train A - Control Room & RSD DH-LT-809 X
P X
X X
R S
D R
S D
Train B - Control Room & RSD
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 4a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
EF-FT-788 S
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD EF-FT-779 S
S X
X X
X R
S D
R S
D Train C - Control Room & RSD EF-FT-782 S
X X
X R
S D
R S
D R
S D
Train B - Control Room & RSD EF-FT-791 S
S X
X X
X R
S D
R S
D Train C - Control Room & RSD FW-LT-1044 (1)
X X
X X
HSPS-Not required.
FW-LT-1040 (2)
X X
X HSPS-Not required.
FW-LT-1045 (3)
X HSPS-Not required.
FW-LT-1041 (4)
X HSPS-Not required.
FW-LT-1046 (1)
X X
X X
HSPS-Not required.
FW-LT-1042 (2)
X X
X HSPS-Not required.
FW-LT-1047 (3)
X HSPS-Not required.
FW-LT-1043 (4)
X HSPS-Not required.
FW-LT-1052 (1)
X X
X X
HSPS. Required in CB-FA-3b.
FW-LT-1048 (2)
X X
X HSPS-Not required.
FW-LT-1053 (3)
X HSPS-Not required.
FW-LT-1049 (4)
X HSPS-Not required.
FW-LT-1054 (1)
X X
X X
HSPS-Not required.
FW-LT-1050 (2)
X X
X HSPS-Not required.
FW-LT-1055 (3)
X HSPS-Not required.
FW-LT-1051 (4)
X HSPS-Not required.
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 5a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
CO-LT-1060 (1)
S S
X X
X X
HSPS-Not required.
CO-LT-1061 (2)
X X
S X
X X
HSPS-Not required.
CO-LT-1062 (1)
S S
X X
X X
HSPS-Not required.
CO-LT-1063 (2)
X X
S X
X X
HSPS-Not required.
MS-PT-950 (1)
S X
P P
X X
X R
S D
R S
D MS-PT-1180 (2)
X X
X HSPS-Not required.
MS-PT-1182 (3)
X HSPS-Not required.
MS-PT-1181 (4)
X HSPS-Not required.
MS-PT-1184 (1)
X X
X X
HSPS-Not required.
MS-PT-951 (2)
X X
X X
R S
D R
S D
R S
D MS-PT-1185 (3)
X HSPS-Not required.
MS-PT-1183 (4)
X HSPS-Not required.
FW-TE-1046 (1)
X X
HSPS-Not required.
FW-TE-1044 (2)
X HSPS-Not required.
FW-TE-1047 (3)
X HSPS-Not required.
FW-TE-1045 (4)
X HSPS-Not required.
FW-TE-1050 (1)
X X
HSPS-Required in CB-FA-3b.
FW-TE-1048 (2)
X HSPS-Not required.
FW-TE-1051 (3)
X HSPS-Not required.
FW-TE-1049 (4)
X HSPS-Not required.
IC5-DPT X
S X
S X
X X
IC9-TE S
S X
X X
Interlock to Close MU-V-1A/1B MU5-TE X
X X
X X
Interlock to Close MU-V-3
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 6a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
MU42-DPT X
X X
S X
S X
X Auto Control for MU-V-32 RC3A-PT-1 X
X X
SP10A-PT-1 X
X SP10A-PT-2 X
X SP10B-PT-1 X
X SP10B-PT-2 X
X DF-LS-244A DF-LS-244B RM-L-1 S
X X
S X
X Interlock to Close MU-V-2A/2B RC3A-PT-3 S
X P
X X
X P
X X
X Train A RC3A-PT-4 S
S X
S X
X Train B RC3B-PT-3 S
S S
X S
Train C BS-PT-282 X
X X
X X
X X
X X
X X
X X
X Train A BS-PT-285 X
X X
X X
X X
S X
S Train B BS-PT 288 X
X S
S X
X X
X Train C BS-PS-932 X
X X
S S
S S
S X
Train A BS-PS-933 X
X X
S S
X S
Train B BS-PS-934 X
X X
S S
S S
S S
X Train C BS-PS-935 X
S S
S S
X Train A BS-PS-936 X
S S
S X
Train B BS-PS-937 X
S S
S X
Train D IC-LT-802 S
X X
X X
X X
Train A. ICCW Tank Level Only IC-LT-803 X
X X
X X
X Train B. ICCW Tank Level Only BS-PS-283 X
X X
X X
X X
X X
Auto Start for BS-P-1A BS-PS-286 X
X X
X X
X X
X X
Auto Start for BS-P-1A BS-PS-289 X
X X
X X
X X
X X
Auto Start for BS-P-1A
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 7a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
BS-PS-284 X
X X
X Auto Start for BS-P-1B BS-PS-287 X
X X
X Auto Start for BS-P-1B BS-PS-290 X
X X
X Auto Start for BS-P-1B IM-SPND-5, 31, 34, 52 (BIRO)
X X
Train A IM-SPND-3, 4, 9, 24 (BIRO)
X X
Train B IM-SPND-12, 13, 21, 38 (BIRO)
X X
Train C IM-SPND-17, 42, 48, 49 (BIRO)
X X
Train D MJ-FT-1126 S
X X
X X
X X
X X
Train A MU-FT-1127 S
X X
X X
X X
X X
Train A MU-FT-1128 X
S X
X X
X Train B MU-FT-1129 X
S X
X X
X Train B
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 NI-11 X
P X
p Train A NI-12 P
X X
X P
P Train B -Control Room & RSD RC4A-TE-1 P
X X
X X
Train X RC4A-TE-4 X
X X
X Train X RC4B-TE-1 X
X X
X Train X RC4B-TE-4 X
X X
X Train X RC-TE-958 X
X X
X X
X Train A - Control Room & RSD RC-TE-960 X
P P
Train B - Control Room & RSD RC5A-TE-2 P
X X
X Train X RC5A-TE-4 P
X X
X Train X RC5B-TE-2 X
X X
Train X RC5B-TE-4 X
X X
X Train X RC-TE-959 X
X X
X X
X X
Train A - Control Room & RSD RC-TE-961 X
P P
Train B - Control Room & RSD RC3A-PT3 P
X X
X X
X X
Train A RC-PT-963 X
X X
X X
X Train A - RSD Only RC-PT-949 X
P P
P Train B - Control Room & RSD RC1-LT-1 X
X X
Train X RC1-LT-3 P
P P
Train X RC-LT-777 X
S X
X X
Train B - Control Room & RSD RC2-TE-1 X
X P
X X
Train X RC2-TE-2 P
X P
X P
Train B FW-LT-775 P
P P
P P
P Train A - Control Room & RSD FW-LT-789 X
X X
Train B - Control Room & RSD FW-LT-788 X
X X
Train A - Control Room & RSD
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 2b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 FW-LT-776 P
P Train B - Control Room & RSD SP6A-PT-1 P
X X
X Train X - Also for MS-V-3D, E, F SP6A-PT-2 P
X X
X Train X - Also for MS-V-3D, E, F MS-PT-950 P
D P
P P
Train A - Control Room & RSD MS-PT-1180 X
X X
X X
Train B SP6B-PT-1 P
X X
Train X - Also for MS-V-3A, B, C SP6B-PT-2 P
X X
Train X - Also for MS-V-3A, B, C MS-PT-951 P
D P
P Train B - Control Room & RSD MS-PT-1184 X
X X
X X
Train A DH-DPT-802 X
X Train A - Control Room & RSD DH-DPT-803 X
Train B - Control Room & RSD DH-FI-299A Train A - Local Indication DH-FI-299B Train B - Local Indication DH2-TE-1 X
X X
Train A - Control Room & RSD DH2-TE-2 X
X X
Train B - Control Room & RSD DH6-TE-1 X
X X
Train A - Control Room & RSD DH6-TE-2 X
X X
Train B - Control Room & RSD CO-LI-1004 Local Indication CO-LI-1005 Local Indication MU14-LT X
X X
Train X MU-LT-778 X
Train B - Control Room & RSD DH-LT-808 X
X X
Train A - Control Room & RSD DH-LT-809 P
X Train B - Control Room & RSD EF-FT-788 X
X X
Train B - Control Room & RSD EF-FT-779 X
X X
X Train C - Control Room & RSD
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 3b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 EF-FT-782 X
X X
Train B - Control Room & RSD EF-FT-791 X
X X
X Train C - Control Room & RSD FW-LT-1044 (1)
X X
X X
X HSPS-Not required.
FW-LT-1040 (2)
X X
X X
HSPS-Not required.
FW-LT-1045 (3)
X X
X X
HSPS-Not required.
FW-LT-1041 (4)
X X
X X
HSPS-Not required.
FW-LT-1046 (1)
X X
X X
X HSPS-Not required.
FW-LT-1042 (2)
X X
X X
HSPS-Not required.
FW-LT-1047 (3)
X X
X X
HSPS-Not required.
FW-LT-1043 (4)
X X
X X
HSPS-Not required.
FW-LT-1052 (1)
X X
X X
HSPS-Required in CB-FA-3b.
FW-LT-1048 (2)
X X
X HSPS-Not required.
FW-LT-1053 (3)
X X
X X
HSPS-Not required.
FW-LT-1049 (4)
X X
X HSPS-Not required.
FW-LT-1054 (1)
X X
X X
HSPS-Not required.
FW-LT-1050 (2)
X X
X HSPS-Not required.
FW-LT-1055 (3)
X X
X X
HSPS-Not required.
FW-LT-1051 (4)
X X
X HSPS-Not required.
CO-LT-1060 (1)
X X
X X
X X
HSPS-Not required.
CO-LT-1061 (2)
X X
X X
HSPS-Not required.
CO-LT-1062 (1)
X X
X X
X X
HSPS-Not required.
CO-LT-1063 (2)
X X
X X
HSPS-Not required.
MS-PT-950 (1)
P D
P P
MS-PT-1180 (2)
X X
X X
X HSPS-Not required.
MS-PT-1182 (3)
X X
X X
X HSPS-Not required.
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 4b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 MS-PT-1181 (4)
X X
X X
X HSPS-Not required.
MS-PT-1184 (1)
X X
X X
X HSPS-Not required.
MS-PT-951 (2)
P D
P P
MS-PT-1185 (3)
X X
X X
X HSPS-Not required.
MS-PT-1183 (4)
X X
X X
X HSPS-Not required.
FW-TE-1046 (1)
X X
X X
X X
X X
HSPS-Not required.
FW-TE-1044 (2)
X X
X X
X X
HSPS-Not required.
FW-TE-1047 (3)
X X
X X
X X
HSPS-Not required.
FW-TE-1045 (4)
X X
X X
X X
HSPS-Not required.
FW-TE-1050 (1)
X X
X X
X X
X X
HSPS-Required in CB-FA-3b.
FW-TE-1048 (2)
X X
X X
X X
X HSPS-Not required.
FW-TE-1051 (3)
X X
X X
X X
X HSPS-Not required.
FW-TE-1049 (4)
X X
X X
X X
X HSPS-Not required.
IC5-DPT X
X X
IC9-TE X
X X
X X
Interlock to Close MU-V-1A/1B MU5-TE X
X X
Interlock to Close MU-V-3 MU42-DPT X
X X
Auto Control for MU-V-32 RC3A-PT-1 P
X X
X X
X X
SP10A-PT-1 X
SP10A-PT-2 X
SP10B-PT-1 X
SP10B-PT-2 X
DF-LS-244A X
DF-LS-244B X
RM-L-1 X
X X
Interlock to Close MU-V-2A/2B
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 5b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 RC3A-PT-3 P
X X
X X
X X
Train A RC3A-PT-4 X
X X
X X
X Train B RC3B-PT-3 X
X X
X Train C BS-PT-282 X
X X
X X
X X
Train A BS-PT-285 X
X X
Train B BS-PT-288 X
X X
Train C BS-PS-932 X
X X
Train A BS-PS-933 X
X X
Train B BS-PS-934 X
X X
Train C BS-PS-935 X
X Train A BS-PS-936 X
X Train B BS-PS-937 X
X Train D IC-LT-802 X
X X
Train A; ICCW Tank Level Only IC-LT-803 X
X Train B; ICCW Tank Level Only BS-PS-283 X
X Auto Start for BS-P-1A BS-PS-286 X
X Auto Start for BS-P-1A BS-PS-289 X
X Auto Start for BS-P-1A BS-PS-284 X
X X
Auto Start for BS-P-1B BS-PS-287 X
X X
Auto Start for BS-P-1B BS-PS-290 X
X X
Auto Start for BS-P-1B IM-SPND-5, 31, 34, 52 (BIRO)
X X
X F
F F
F F
F F
Train A IM-SPND-3, 4, 9, 24 (BIRO)
X X
X F
F F
F F
F F
Train B IM-SPND-12, 13, 21, 38 (BIRO)
X X
X F
F F
F F
F F
Train C
ATTACHMENT 3-5P APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 6b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air F
- One or Other is Available Rev. 27 INSTRUMENTATION AND CONTROLS D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T Y
G G
H H
H H
H H
B B
B B
B B
B B
S S
S S
B B
B B
B B
B B
A P
P P
P R
F F
F F
F F
F F
F F
F F
F F
F F
H H
H H
F F
F F
F F
F F
D A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 IM-SPND-17, 42, 48, 49 (BIRO)
X X
X F
F F
F F
F F
Train D MU-FT-1126 X
X Train A MU-FT-1127 X
X Train A MU-FT-1128 X
X Train B MU-FT-1129 X
X Train B
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1a LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker Note 2:
Signal conditioning cabinet B3 is not available in CB-FA-2b.
M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room T1
- Crosstie 1P and 1S 480V Switchgear T2
- Crosstie 1A and 1B DC Panels Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
EE-SWG-4160V-1D X
X X
S X
S X
X Train A EE-SWG-4160V-1E P
X X
S X
R S
D R
S D
R S
D Train B EG-Y-1A X
X P
X S
X P
X X
X Train A EG-Y-1B P
X S
S P
X R
S D
R S
D R
S D
Train B EE-SWG-480V-1P X
X P
X S
X P
X X
X Train A EE-SWG-480V-1S P
X X
P X
X R
S D
R S
D R
S D
Train B EE-SWG-480V-1R X
X X
X S
X P
X X
X Train A EE-SWG-480V-1T X
P X
X X
P X
X R
S D
R S
D R
S D
Train B EE-MCC-ES-1A X
X X
S S
S X
X Train A EE-MCC-ES-1B X
X P
X S
R S
D R
S D
R S
D Train B EE-MCC-ESV-1A X
X X
X S
S S
S S
S Train A EE-MCC-ESV-1B X
X P
X S
S S
R S
D R
S D
R S
D Train B EE-MCC-ESV-1C-EX1 (1C ESV MCC Transfer Switch)
X P
X R
S D
R S
D R
S D
R S
D Train C EE-MCC-ESV-1C P
X S
R S
D R
S D
R S
D Train C EE-MCC-SH-1A X
X X
S S
X S
X X
Train A
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 2a LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker Note 2:
Signal conditioning cabinet B3 is not available in CB-FA-2b.
M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room T1
- Crosstie 1P and 1S 480V Switchgear T2
- Crosstie 1A and 1B DC Panels Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
EE-MCC-SH-1B X
X X
X P
X S
R S
D R
S D
R S
D Train B EE-PNL-ATA X
X S
Train X EE-PNL-ATB X
X S
Train X EE-PNL-VBA X
T2 X
S T2 T2 T2 T2 Train A EE-PNL-VBB P
T2 S
X S
T2 Train B EE-PNL-VBC X
T2 X
S T2 T2 T2 T2 Train C EE-PNL-VBD P
T2 S
X S
T2 Train D EE-INV-1A X
T2 X
S T2 T2 T2 T2 Train A EE-INV-1B P
T2 X
X S
T2 Train B EE-INV-1C X
T2 X
S T2 T2 T2 T2 Train C EE-INV-1D P
T2 X
X S
T2 Train D EE-INV-1E (Note 1)
X T2 X
S S
S S
S Train C EE-INV-1F S
X S
Train B or D EED-BC-1A X
X X
S S
S S
S Train A EED-BC-1B P
X X
S S
Train B EED-BC-1C X
X X
S S
S S
S Train C EED-BC-1D P
X X
S S
Train D EED-PNL-1A X
T2 X
X T2 T2 T2 T2 Train A EED-PNL-1B P
T2 X
X T2 Train B EED-PNL-1M X
X X
X X
Train C EED-PNL-1E X
X S
Train A EED-PNL-1F P
X S
Train B EED-PNL-1P X
X S
Train A EED-PNL-1Q P
X S
Train B
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 3a LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker Note 2:
Signal conditioning cabinet B3 is not available in CB-FA-2b.
M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room T1
- Crosstie 1P and 1S 480V Switchgear T2
- Crosstie 1A and 1B DC Panels Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
EE-PNL-TRA X
X X
X S
S S
S S
Train X EE-PNL-TRB X
X X
X S
S Train X SCC-A1, A2, A3 S
X P
X S
X Train A SCC-B1, B2, B3 X
X S
Train B (Note 2)
RSP-A S
X S
S X
Train A; RSD RSP-B S
X S
S Train B; RSD RSTSP-A X
X X
X X
R S
D R
S D
Train A, X; RSD RSTSP-B X
X R
S D
R S
D R
S D
Train B, C, X; RSD RSTSP-C X
X X
R S
D R
S D
R S
D Train C; RSD ESAS Bistable Cabinets S
X S
X X
ESAS Relay Cabinets A
S X
X S
X X
ESAS Defeat A S
S S
S X
X X
X X
ESAS Relay Cabinets B
B X
B X
B S
X X
ESAS Defeat B S
S S
X X
X X
Emergency Control Room Lighting (AC)
X X
S S
S S
S X
X Train A: EED-PNL-CT-2 (Upper)
Normal Control Room Lighting (AC)
X X
S S
S X
S X
X Train B: EED-PNL-CT-2 (Lower)
Emergency Control Room Lighting (DC)
S S
X S
X X
Train C: EED-PNL-1M FS-PNL-CB-1 (CARDOX)
O Train X. O = Open CT-5 Switch 32 at 1A ES MCC Unit 8A
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1b LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T G
G H
H H
H H
H B
B B
B B
B B
B S
S S
S B
B B
B B
B B
B P
P P
P F
F F
F F
F F
F F
F F
F F
F F
F H
H H
H F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 EE-SWG-4160V-1D X
Train A EE-SWG-4160V-1E X
Train B EG-Y-1A X
Train A EG-Y-1B X
Train B EE-SWG-480V-1P S
Train A EE-SWG-480V-1S S
Train B EE-SWG-480V-1R S
X X
X P
Train A EE-SWG-480V-1T S
P X
X P
X Train B EE-MCC-ES-1A S
Train A EE-MCC-ES-1B S
Train B EE-MCC-ESV-1A S
X X
Train A EE-MCC-ESV-1B S
X Train B EE-MCC-ESV-1C-EX1 (1C ESV MCC Transfer Switch)
Train C EE-MCC-ESV-1C X
P Train C EE-MCC-SH-1A S
X X
X P
Train A EE-MCC-SH-1B S
P X
X P
X Train B EE-PNL-ATA Train X EE-PNL-ATB Train X EE-PNL-VBA T1 Train A EE-PNL-VBB T1 Train B EE-PNL-VBC T1 Train C EE-PNL-VBD T1 Train D EE-INV-1A T1 Train A EE-INV-1B T1 Train B
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 2b LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T G
G H
H H
H H
H B
B B
B B
B B
B S
S S
S B
B B
B B
B B
B P
P P
P F
F F
F F
F F
F F
F F
F F
F F
F H
H H
H F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 EE-INV-1C T1 Train C EE-INV-1D T1 Train D EE-INV-1E (Note 1)
T1 Train C EE-INV-1F Train B EED-BC-1A T1 Train A EED-BC-1B T1 Train B EED-BC-1C T1 Train C EED-BC-1D T1 Train D EED-PNL-1A T1 Train A EED-PNL-1B T1 Train B EED-PNL-1M Train C EED-PNL-1E Train A EED-PNL-1F Train B EED-PNL-1P X
Train A EED-PNL-1Q X
Train B EE-PNL-TRA S
X X
Train X EE-PNL-TRB S
X X
Train X SCC-A1, A2, A3 Train A SCC-B1, B2, B3 Train B RSP-A Train A; RSD RSP-B Train B; RSD RSTSP-A Train A, X; RSD RSTSP-B Train B, C, X; RSD RSTSP-C Train C; RSD ESAS Bistable Cabinets
ATTACHMENT 3-5Q APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 3b LEGEND X - Component Not Available D
- Design Modification Note 1:
For fire areas where the DC cross tie (T2) is used to energize Train A, manual action is taken to lockout inverter 1E.
S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air B - Use ES Bypass in Control Room Rev. 27 AUXILIARY ELECTRICAL POWER SYSTEM D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T G
G H
H H
H H
H B
B B
B B
B B
B S
S S
S B
B B
B B
B B
B P
P P
P F
F F
F F
F F
F F
F F
F F
F F
F H
H H
H F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 ESAS Relay Cabinets A
ESAS Defeat A ESAS Relay Cabinets B
ESAS Defeat B Emergency Control Room Lighting (AC)
S X
X Train A: EE-PNL-CT-2(Upper)
Normal Control Room Lighting (AC)
S Train B: EE-PNL-CT-2(Lower)
Emergency Control Room Lighting (DC)
X Train C: EED-PNL-1M FS-PNL-CB-1 (CARDOX)
X Train X. O = Open CT-5 Switch 32 at 1A ES MCC Unit 8A.
ATTACHMENT 3-5R APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1a LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air Rev. 27 INSTRUMENT AIR A
A A
A A
A A
A A
A A
A A
A A
A A
A C
C C
C C
C C
C C
C C
C C
C C
C B
B B
B B
B B
B B
B B
B B
B B
B I
I B
B B
B B
B B
B B
B B
B B
B B
B T
T F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z F
F A
A A
A A
A A
A A
A A
A A
A Z
Z Z
Z 1
2 1
2 2
2 3
4 5
6 6
7 8
9 1
1 1
2 2
2 2
2 2
2 3
3 3
3 4
4 5
5 COMPONENTS a
b c
a 0
1 1
1 a
b c
d e
f g
a b
c d
a b
a b
REMARKS a
IA-P-1A X
X X
S S
S X
X IA-P-1B X
X X
S X
S S
R S
D R
S D
Normal Instrument Air Line (Copper)
X X
X X
X X
X X
X X
2-Hour Backup Instrument Air System Steel Tubing; Except at Valve Location (Copper)
ATTACHMENT 3-5R APPENDIX R EVALUATION REPORT - THREE MILE ISLAND UNIT 1 COMPONENT AVAILABILITY FOR A FIRE IN FIRE AREA/ZONE SHEET 1b LEGEND X - Component Not Available D
- Design Modification S - Support Not Available RSD - Remote Shut Down P - Available-Cable Protected O
- Open Switch or Breaker M - Available-Manual Operation R
- Repair A - Manual Op. Due to Loss of Inst. Air Rev. 27 INSTRUMENT AIR D
D F
F F
F F
F I
I I
I I
I I
I I
I I
I R
R R
R R
R R
T G
G H
H H
H H
H B
B B
B B
B B
B S
S S
S B
B B
B B
B B
B P
P P
P F
F F
F F
F F
F F
F F
F F
F F
F H
H H
H F
F F
F F
F F
F A
A Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z Z
A F
F F
F 1
2 1
2 3
4 5
6 1
2 3
4 5
6 7
8 A
Z Z
Z 1
1 1
1 1
2 3
1 COMPONENTS a
b c
d e
REMARKS 2
1 2
3 IA-P-1A S
X X
X X
IA-P-1B S
X X
S X
X Normal Instrument Air Line (Copper)
X X
X X
X X
X X
X X
X X
X X
X X
2-Hour Backup Instrument Air System X
X X
Steel Tubing; Except at Valve Location (Copper)