ATTACHMENT Palisades Nuclear Plant Steam Generator Tube Inspection Report 2015 Refueling Outage, 1 R24 AREVA Inc. Document Number 51 ~9252894-001 92 pages follow
A 20004-021 (01/30/2014)
AREVA AREVA Inc.
Engineering Information Record Document No.:
51 9252894 -
001
~~~~~~~~~-
Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Page 1of92
A AREVA 20004-021 (01/30/2014)
Document No.: 51-9252894-001 Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Safety Related?
[ZJYES ONO Does this document establish design or technical requirements?
DYES
[ZJ NO Does this document contain assumptions requiring verification?
DYES
[ZJ NO Does this document contain Customer Required Format?
~YES D NO Signature BIQck Pages/Sections Nameand Title/Discipline P/LP, R/LR, Prepared/Reviewed/
Signature A-CRF, A Date Approved or Comments Kent Colgan Advisory Engineer Craig Kelley Supervisory Engineer Paul Ulmer Project Manager James Campbell Manager p
R A-CRF Note: P/LP designates Preparer (P), Lead Preparer (LP)
R/LR designates Reviewer (R), Lead Reviewer (LR) o3/ fl,/p;lt All All 3/1(;./ l-f,
/t64bl{,
All 3/&/tt All A-CRF designates Project Manager Approver of Customer Required Format (A-CRF)
A designates Approver/RTM - Verification of Reviewer Independence Project Manager Approval of Customer References (N/A if not applicable)
Name Title (printed or typed)
{printed or typed)
Signature N/A N/A N/A Date N/A Page2
A AREVA Revision No.
000 001 20004-021 (01 /30/2014)
Document No.: 51-9252894-001 Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Record of Revision Pages/Sections/
Paragraphs Changed Brief Description I Change Authorization N/A Original release Page3 Updated record of revision Page 10 Corrected Table 3 title Page 3
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table of Contents Page SIGNATURE BLOCK............................................................................................................................. 2 RECORD OF REVISION....................................................................................................................... 3 LIST OF TABLES.................................................................................................................................. 5 LIST OF FIGURES................................................................................................................................ 6 1.0 PURPOSE................................................................................................................................. 7 2.0 ASSUMPTIONS......................................................................................................................... 7 3.0 INPUTS...................................................................................................................................... 7 4.0 180-DA Y REPORT..................................................................................................................... 7
5.0 CONCLUSION
......................................................................................................................... 18
6.0 REFERENCES
......................................................................................................................... 18 APPENDIX A:* ACRONYMS AND ABBREVIATIONS....................................................................... A-1 APPENDIX B: STEAM GENERATOR LAYOUT AND NOMENCLATURE......................................... B-1 APPENDIX C: SUPPORT WEAR LISTING - SGA........................................................................... C-1 APPENDIX D : SUPPORT WEAR LISTING - SGB........................................................................... D-1 Page4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 List of Tables Page Table 1: Refueling Outage (RFO) Information since SG Replacement.................................................. 8 Table 2: Eddy Current Tube Inspection Scope...................................................................................... 9 Table 3: Active Degradation Mechanisms........................................................................................... 10 Table 4: Eddy Current Techniques Utilized......................................................................................... 1 O Table 5: Axial ODSCC Indications...................................................................................................... 13 Table 6: Circumferential ODSCC Indication........................................................................................ 14 Table 7: Historical Foreign Object Wear Indications (Volumetric) - No Object Present........................ 14 Table 8: New Foreign Object Wear Indications (Volumetric) - Object Present.................................... 14 Table 9: Diagonal Bar Wear Summary................................................................................................ 14 Table 1 O: Vertical Strap Wear Summary............................................................................................. 15 Table 11: Egg crate Wear Summary.................................................................................................... 15 Table 12: Tubes Affected by Support Wear........................................................................................ 15 Table 13: Number of Tubes Plugged.................................................................................................. 16 Table 14: Specific Tubes Plugged...................................................................................................... 17 Table 15: Overall Plugging Summary.................................................................................................. 17 Table 8-1: Palisades SG Tube Support Structure Nomenclature....................................................... 8-2 Page 5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 List of Figures Page Figure 8-1: General Layout of Palisades SG Tube Support Structures.............................................. 8-1 Figure 8-2: Palisades SG Tubesheet Map......................................................................................... 8-2 Page6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1.0 PURPOSE The purpose of this document is to provide the 1 R24 steam generator (SG) tube inspection report in accordance with Palisades Technical Specification 5.6.8, "Steam Generator Tube Inspection Reports."
The report is provided in its entirety in Section 4.0 and the appendices of this document, from which it may be copied and modified as necessary by the Palisades Licensing Department.
2.0 ASSUMPTIONS No assumptions were used in the preparation of this document.
3.0 INPUTS The information summarized in this report was extracted from References [1] and [2].
4.0 180-DAY REPORT Introduction Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports, requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report is required to address the following items:
- a. The scope of inspections performed on each SG
- b. Active degradation mechanisms found
- c. Nondestructive examination techniques utilized for each degradation mechanism
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications
- e. Number of tubes plugged during the inspection outage for each active degradation mechanism
- f.
Total number and percentage of tubes plugged to date
- g. The results of condition monitoring, including the results of tube pulls and in-situ testing
- h. The effective plugging percentage for all plugging in each SG.
Entergy and AREVA performed a SG inspection in accordance with TS 5.5.8 during the Palisades fall
- 2015 refueling outage (1R24). This inspection was the 16th in-service inspection following SG replacement and the 3rd of 3 scheduled inspections in the fourth sequential Inspection period. Initial entry into mode 4 occurred on October 17, 2015; therefore, this report is required to be submitted by April 14, 2016.
The following section ("Background") briefly describes the Palisades SG design characteristics and operating history, while the subsequent section ("Specific Responses") provides responses to each of the TS 5.6.8 questions. Appendix A provides definitions for the acronyms and abbreviations used in this report.
Page7
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24
Background
Palisades is a Combustion Engineering (CE) PWR equipped with two CE Model 2530 replacement steam generators. These steam generators were installed in the early 1990's as replacements for the original steam generators. Each steam generator contains 8219 lnconel 600 tubes with an outer diameter of 0.75 inches and nominal wall thickness of 0.042 inches. The tubes are arranged in a 1-inch triangular-pitch pattern comprised of 138 rows and 165 columns. The tubes in rows 1 through 18 are of u-bend design with a minimum bend radius of 2.5 inches (row 1) and maximum radius of 11 inches (row 18). The tubes in Rows 19 through 138 are of "square-bend" design consisting of two 90 degree bends of constant radius with a straight horizontal section of tubing of varying length between the two bends. The tubes were explosively expanded throughout the full tubesheet depth and are supported by several structures which include horizontal eggcrate supports, diagonal bars, and vertical strap supports. All of the support structures were fabricated with stainless steel. The general layout of the steam generator internals and associated nomenclature are provided in Appendix B.
The Palisades SGs had accrued 19. 73 effective full power years (EFPY) of operation through the end of cycle 24 (i.e., 1 R24) with a nominal hot leg temperature of 583°F. The 1 R24 inspection of the two Palisades SGs was the 161h in-service inspection (ISi) following SG installation in 1990, and the last of three scheduled inspections in the fourth sequential inspection period (Table 1).
Table 1: Refueling Outage (RFO) Information since SG Replacement Outage Cycle Outage Year EFPD 1R9 1992 298.5 1R10 1993 356.8 1R11 1995 430.5 1R12 1996 407.4 1R13 1998 419.6 1R14 1999 449.3 1R15 2001 401.3 1R16 2003 444.3 1R17 2004 493.1 1R18 2006 487.9 1R19 2007 459.3 1R20 2009 499.8 1R21 2010 507.7 1R22 2012 504.0 1R23 2014 513.3 1R24 2015 539.5 EFPD = effective full power days EFPM = effective full power months EFPY =effective full power years Cumulative EFPY 0.82 1.79 2.97 4.09 5.24 6.47 7.57 8.78 10.13 11.47 12.73 14.09 15.48 16.84 18.25 19.73 First Second Third Inspection Inspection Inspection Period Period Period (EFPMs)
(EFPMs)
(EFPMs) 9.84 11.72 25.87 39.25 53.04 7.80 20.98 35.58 51.78 7.81 22.90 39.32 56.00 Fourth Inspection Period (EFPMs) 12.54 29.14 46.86 Page 8
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Specific Responses This section provides responses to each of the requirements specified by TS 5.6.8. Bold wording represents TS verbiage. The required information is provided immediately following the restatement of each reporting requirement.
A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.8, Steam Generator (SG) Program. The report shall include:
- a.
The scope of inspections performed on each SG The 1 R24 work scope in both SGs (SGA and SGB) included eddy current (ECT) inspections, primary side visual inspections, and secondary side visual inspections. A summary of the ECT inspections performed is provided in Table 2.
Table 2: Eddy Current Tube Inspection Scope Scope Probe Type SGA SGB Full LengthCD Bobbin 100%
100%
Row 1 through 3 U-bends MRPC 100%
100%
Hot Leg Tubesheets TTS+3"/-13.5" MRPC 100%
100%
Cold Leg Outer Three Periphery Tubes TTS+3"/-2" for detection of possible loose MRPC 12.8%
12.7%
parts or wear signals<Il Freespan Dings >5.0 Volts between TSH MRPC and TSC 100%
100%
Dents >2.0 Volts at Vertical Straps, Diagonal MRPC Bars & Eggcrates between TSH and TSC 100%
100%
Wear at Eggcrates (Current and Historical)
MRPC 100%
100%
Historical Wear at Diagonal Bars and MRPC 25%
25%
Vertical Straps Supplemental MRPC 100%
100%
CD Except for the bend portion of rows 1 through 3 CV The values shown are percentages of the installed tube population All DOI, OSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications The primary side inspection scope included a visual examination of both legs of the primary channel heads of both SGs. This examination was performed in the as-found state (prior to any other SG inspections), and in the as-left state (after all other SG inspections were completed). The purpose of the examinations was to assess the general material condition, to assess the condition of all installed Page 9
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 tube plugs, to assess the integrity of the cladding, and to identify and remove any foreign objects present (none were identified). No anomalous conditions were identified during these inspections. All plugs were present in the proper location and no degradation was observed.
The secondary side work scope included a Foreign Object Search and Retrieval (FOSAR) inspection at the top-of-tubesheet (TIS) in the tube-to-shell annulus and divider lane in both SGs. All visually accessible passages between tubes were viewed from the tube bundle periphery on each leg.
- b.
Active degradation mechanisms found The degradation mechanisms identified during the 1 R24 SG examinations are described in Table 3. No new degradation mechanisms were identified.
Table 3: Active Degradation Mechanisms SG Location Damage Mechanism Both Diagonal Bar (DB) Support Wear Both Vertical Strap (VS) Support Wear Both Eggcrate (EC) Support Wear Both Adjacent to Foreign Object (FO)
Wear Both Hot Leg EC Supports Axial ODSCC Both Hot Leg Top-of-Tubesheet (TTS)
Axial ODSCC SGA Hot Leg Top-of-Tubesheet (TTS)
Circumferential ODSCC
- c.
Nondestructive examination techniques utilized for each degradation mechanism The nondestructive examination techniques utilized during 1 R24 for each potential and existing degradation mechanism are identified in Table 4. In all cases the utilized NOE techniques were based on the eddy current method.
Table 4: Eddy Current Techniques Utilized Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Bobbin Probe Tube to Tube Bobbin 13091.1 Freespan tube-to-tube None Yes Yes Wear Rev. 0 wear Freespan (excluding u-Axial ODSCC Bobbin 128413 bend), eggcrate, sludge None Yes No Rev. 3 pile, & broached TSPs with or without dents S2Vpp Axial ODSCC Bobbin 24013.1 Freespan including dings None Yes No Rev. 2 S5V Page 10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Foreign 27091.2 Foreign object wear Extended for Object Wear Bobbin Rev. 1 (part not present); 1-690 1-600 tubing Yes Yes tubing 96004.1 AVBs, TSPs, Support Wear Bobbin Rev. 13 vertical and diagonal Dents <5V Yes Yes straps Pitting Bobbin 96005.2 Freespan in the Sludge Pile Yes Yes Rev. 9 presence of copper Axial ODSCC 128424 Depth:
Rev. 3 Yes (detect);
TSP (with or without dents BED:
Axial ODSCC
+Point' None Yes 128431
<=2vpp) and sludge pile Yes Rev.,2 BEL:
(sizing)
Yes 128425 Depth:
Rev. 3 Yes (detect)
Freespan (excluding u-Axial ODSCC
+Point' bend), eggcrate, &
None Yes BED:
128432 broached TSPs with or Yes Rev.2 without dents ::;2Vpp (sizing)
BEL:
Yes Axial ODSCC
+Point' 10411.1 Low Row U-bends Higher Row Yes Depth:
Rev. 0 U-bends Yes PDA:
21409.1 Support structures, Info" Axial ODSCC
+Point' Rev. 7 freespan, sludge pile, &
U-bends Yes tubesheet crevice Length:
Info Freespan dings &
Depth:
Info Axial ODSCC
+Point' 22401.1 Dented TSPs dented eggcrates, Yes Rev. 4 diagonal bars and Length:
vertical straps Yes Axial PWSCC Depth:
Yes Axial PWSCC
+Point' 20511.1 Expansion Transitions Tubesheet Yes PDA:
Rev. 8 Info Length:
Yes Depth:
96703.1 Tubesheet, Yes Axial PWSCC
+Point' Dents/Dings Yes Rev. 17 Dented supports Length:
Yes Page 11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Axial PWSCC
+Point' 96511.2 Low Row U-bends Higher Row Yes Depth:
Rev. 16 U-bends Yes
+Point' 99997.2 Higher Row Depth:
Axial PWSCC High Low Row U-bends Yes Freq Rev. 10 U-bends Yes Circumferential ODSCC Depth:
21410.1 U-bends, Info Circ ODSCC
+Point' Rev. 6 Expansion Transitions freespan dings, Yes Note 4 dented supports PDA:
Yes Circ ODSCC
+Point' 22842.1 Dented Supports Freespan dings, Yes Length:
Rev.4 u-bends Yes Circumferential PWSCC 111524 U-bends, Circ PWSCC
+Point' Rev. 0 Expansion Transitions Dents/Dings, Yes No Tubesheet Depth:
Yes Circ PWSCC
+Point' 20510.1 Expansion Transitions U-bends No (see PDA:
Rev. 7 111524)
Yes Length:
Yes Circ PWSCC
+Point' 96511.2 See "Axial PWSCC" section of this table Rev. 16 Depth:
Yes Circ PWSCC
+Point' 96701.1 Expansion Transitions Dents/Dings and No (see PDA:
Rev. 12 tubesheet 111524)
Yes Length:
Yes
+Point' 99997.2 Circ PWSCC High Rev. 10 See "Axial PWSCC" section of this table Freq Wear Tube to Tube
+Point' 13901.1 Freespan tube-to-tube U-bends Yes Depth:
Wear Rev. 1 wear Yes Dented/non-10908.4 dented Supports, Depth:
Wear
+Point' Rev. 1 AVBs Foreign object Yes Yes wear (part present)
Foreign
+Point' 27901 Foreign object wear Volumetric or.115 through Freespan Wear Yes Yes Object Wear*
Pancake 27907 (part not present)
(part not present)
Pitting Page 12 J
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Pitting
+Point' 21998.1 Volumetric in freespan Sludge Pile Yes Depth:
Rev.4 Yes
- Multiple ETSSs are available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used.
- d.
Location, orientation (if linear), and measured sizes (if applicable) of service induced indications The location, orientation, and measured size of axial ODSCC, circumferential ODSCC, and foreign object wear indications identified during the 1 R24 outage are provided in Table 5, Table 6, Table 7, and Table 8. Due to the large number support wear indications, the required data is provided in Appendix C.
Statistical summaries of throughwall depth, growth rates of support wear populations (i.e., diagonal bar, vertical strap, and egg crate wear), and the number of tubes affected by support wear are provided in Table 9, Table 10, Table 11, and Table 12. In these tables, "New" refers to support wear indications that were newly reported during the 1 R24 outage, and "Repeat" refers to support wear indications reported during previous outage inspection(s) and again measured during 1 R24.
Table 5: Axial ODSCC Indications NOE
+Point 300 Maximum Structural kHz Depth Depth Amplitude
(%TW)
NOE Axial Structural
(%TW)
SG Row Col.
Location (Vpp)
(Note 1)
Length (in.)
Length (in.)
(Note 1)
A 11 110 02H-0.53" 0.35 46.0 0.80 0.3 34.4 A
37 118 TSH+0.65" 0.65 59.8 0.38 0.16 48.4 A
40 117 TSH+0.51" 0.64 59.5 0.67 0.32 49.2 A
75 86 TSH+1.22" 0.40 51.7 0.22 A
78 97 TSH+0.61" 0.39 51.3 0.25 A
83 88 TSH+0.41" 0.30 47.0 0.19 A
105 98 TSH+0.30" 0.83 63.8 0.22 0.16 55.0 B
35 116 TSH+0.85" 0.26 44.6 0.29 B
49 112 TSH+0.40" 0.39 51.3 0.29 B
72 93 02H-0.67" 0.32 44.2 0.56 B
75 94 TSH+1.25" 0.30 47.0 0.32 B
76 91 TSH+1.09" 0.54 56.7 0.29 0.16 50.6 Note 1) The NOE maximum depth values were calculated using the Appendix I regression techniques (%TW as function of NOE voltage) and then reduced by 11 %TW in accordance with the Entergy Appendix I deviation.
Both the NOE maximum depth and structural depth values, shown in this table, reflect the 11 % TW reduction.
Page 13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 6: Circumferential ODSCC Indication NOE Percent Degraded Area
+Point 300 kHz (PDA)
Circumferential SG Row Col Location Amplitude (Vpp)
(Note 1)
Length (deg.)
A 59 60 TSH+O.O" 0.83 6
58 Note 1) The percent degraded area (PDA) of the circumferential indication was determined using the EPRI Draw Program based on measurements from EPRI ETSS H-21410.1.
Table 7: Historical Foreign Object Wear Indications (Volumetric) - No Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (%TW)
Extent (0 )
Extent (in.)
A 130 63 TSH + 1.46 21998.1 20 29 0.45 8
137 92 TSH + 10.76 21998.1 22 31 0.33 8
137 92 TSH+11.85 21998.1 22 31 0.33 Table 8: New Foreign Object Wear Indications (Volumetric) - Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (%TW)
Extent (0 )
Extent (in.)
A 33 162 TSH + 13.23" 10908.4 14 29 0.27 A
127 110 TSH + 1.08" 10908.4 33 23 0.38 A
129 110 TSH + 0.57" 10908.4 15 31 0.32 Table 9: Diagonal Bar Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
5 139 13.9 26.0 35.0 0.2 2.7 8.1 B
5 105 "16.9 27.0 31.0 0.7 4.1 7.4 Both 10 244 15.2 27.0 35.0 0.4 3.4 8.1 SGs Page 14 J
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 10: Vertical Strap Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
3 668 17.0 31.0 39.0 0.1 2.7 8.1 B
3 704 19.2 32.0 39.0 0.4 3.4 10.2 Both 6
1372 18.1 32.0 39.0 0.3 3.4 10.2 SGs Table 11: Eggcrate Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
18 1064 14.1 22.0 34.0 0.2 2.7 5.4 B
8 937 15.3 22.8 39.0 0.3 2.7 5.4 Both 26 2001 14.7 22.0 39.0 0.2 2.7 5.4 SGs Table 12: Tubes Affected by Support Wear SG Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear A
139 402 825 B
106 441 769
- e.
Number of tubes plugged during the inspection outage for each active degradation mechanism The number of tubes plugged during the 1 R24 outage, categorized by degradation mechanism, is summarized in Table 13, while Table 14 identifies each tube that was plugged.
All of the tubes with ODSCC indications were plugged and the circumferential ODSCC indication was stabilized prior to plugging. None of the support wear indications exceeded the technical specification plugging limit of 40% TW; hence, none of the affected tubes required plugging.
Two foreign objects in SG A caused wear in three tubes (Table 8). The objects were not retrievable and consequently, the affected tubes were stabilized and plugged. Two additional tubes (SGA R31 C162, SGA R32 C161) adjacent to one of the objects, were preventively stabilized and plugged even though neither had experienced degradation. This was done to address the potential that the object could Page 15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 degrade these tubes in the future. Historical foreign object wear indications in three tubes (Table 7) were again measured and confirmed to have experienced no growth since the 1 R23 examination. This result was expected since no foreign object remains at the location. The indications did not exceed the technical specification plugging limit of 40% TW; consequently, these tubes were returned to service following 1 R24.
No inspection data quality issues or tube restriction issues were experienced; therefore, no tubes required plugging for these causes.
Table 13: Number of Tubes Plugged SGA SGB Total Location Tubes Tubes Tubes Tubes Tubes Tubes Plugged Stabilized Plugged Stabilized Plugged Stabilized Axial ODSCC at EC Support 1
0 1
0 2
0 Axial ODSCC at TTS 6
0 4
0 10 0
Circ ODSCC at TTS 1
1 0
0 1
1 Foreign Object (Note 1) 2 2
0 0
2 2
Foreign Object Wear 3
3 0
0 3
3 Wear at Supports 0
0 0
0 0
0 Obstructed 0
0 0
0 0
0 Total 13 6
5 0
18 6
Note 1: Tubes SGA R31 C162 and SGA R32 C161 were preventatively plugged to bound a foreign object (no wear)
Page 16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 14: Specific Tubes Plugged SG Row Col Reason for Plugging Stabilized A
11 110 Axial ODSCC at EC Support No A
31 162 Preventive (adjacent foreign object)
Yes A
32 161 Preventive (adjacent foreign object)
Yes A
33 162 Foreign Object Wear Yes A
37 118 Axial ODSCC at TTS No A
40 117 Axial ODSCC at TTS No A
59 60 Circumferential ODSCC at TTS Yes A
75 86 Axial ODSCC at TTS No A
78 97 Axial ODSCC at TTS No A
83 88 Axial ODSCC at TTS No A
105 98 Axial ODSCC at TTS No A
127 110 Foreign Object Wear Yes A
129 110 Foreign Object Wear Yes B
35 116 Axial ODSCC at TTS No B
49 112 Axial ODSCC at TTS No B
72 93 Axial ODSCC at EC Support No B
75 94 Axial ODSCC at TTS No B
76 91 Axial ODSCC at TTS No
- f.
Total number and percentage of tubes plugged to date The overall plugging status of the Palisades SGs to-date is summarized in Table 15. Because there are no sleeves installed, the total number of tubes plugged and the total number of effective tubes plugged are identical.
Table 15: Overall Plugging Summary SGA SGB Total Total Tubes Installed 8219 8219 16438 Tubes Plugged Pre-Service 308 309 617 Tubes Plugged During Service 242 142 384 Total Tubes Plugged to Date 550 451 1001 Effective Tubes Plugged to Date 550 451 1001 Effective Plugging Percentage 6.7 5.5 6.1 Page 17
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24
- g.
The results of condition monitoring, including the results of tube pulls and in-situ testing No tubes were pulled and, based upon the results of the 1 R24 inspections, no tubes required in-situ pressure testing. The condition monitoring assessment concluded that the structural integrity criteria (TS 5.5.8b.1) and accident induced leakage performance criteria (TS 5.5.8b.2) were satisfied during the operating interval preceding 1 R24. Operational leakage monitoring during cycle 24 indicated stable, low level primary to secondary leakage. The indicated leakage was approximately 5 GPO at the beginning of the cycle and trended downward throughout the cycle to approximately 1.5 GPO. Consequently, the plant specific operational leakage performance criterion (150 GPO, TS 5.5.8b.3, LCO 3.4.13d) was also satisfied throughout the cycle.
- h.
The effective plugging percentage for all plugging in each SG Since no sleeving has been performed in the Palisades steam generators, the effective plugging percentage is the same as the actual plugging percentage (see (f)).
5.0 CONCLUSION
The 180-day steam generator tube inspection report for the Palisades 1 R24 refueling outage is provided in its entirety in Section 4.0 and the appendices, from which it may be copied and modified as necessary by the Palisades Licensing Department.
6.0 REFERENCES
- 1.
AREVA Document 51-9243395-001, "Steam Generator Degradation Assessment for Palisades 1 R24 Inspection, Fall 2015,"
- 2.
AREVA Document 51-9248748-001, "Palisades Steam Generator Condition Monitoring for 1 R24 and Final Operational Assessment for Cycle 25,"
Page 18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX A: ACRONYMS AND ABBREVIATIONS Acronym Definition AVB Anti-Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DDI Dent or Ding with Indication DSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AREVA Data Management System LP Loose Part MRPC Motorized Rotating Pancake Coil (+Pt.')
MBM Manufacturing Burnish Mark NOD No Degradation Detected NOE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWR Pressurized Water Reactor PWSCC Primary Water Stress Corrosion Cracking SAi Single Axial Indication SCI Single Circumferential Indication SGA Steam Generator E-50A SGB Steam Generator E-50B SVI Single Volumetric Indication TBP To Be Plugged TSP Tube Support Plate TTS Top of Tubesheet TW Through Wall
%TW Percent throughwall
<TS Less Than Technical Specification Plugging Limit WAR Wear Indication Page A-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX B: STEAM GENERATOR LAYOUT AND NOMENCLATURE Figure B-1: General Layout of Palisades SG Tube Support Structures DBH DSC OBH 08C 07H 07C OGH 0SC 05H 05C 04H 04C 03H 03C 02H 02C OlH 01C TSH*
TSC TEH*
TEC
___/
Page 8-1
Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Figure 8-2: Palisades SG Tubesheet Map 160 150 140 130 12!l 110 60 50 40 30 2!l 10 Table 8-1: Palisades SG Tube Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top ofTubesheet-Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS?
Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side DSC Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side Page B-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1R24 APPENDIX C: SUPPORT WEAR LISTING - SGA Depth No SG Row Column
(%TW)
Location Elevation Status 1
A 1
128 15 02C 0.72
<TS 2
A 1
136 15 02H
-1.04
<TS 3
A 1
140 7
DBH
-0.99
<TS 4
A 1
150 13 01C
-0.2
<TS 5
A 1
150 21 02C 0.82
<TS 6
A 1
162 11 01C 0.83
<TS 7
A 2
127 22 05C 0.81
<TS 8
A 2
159 12 03C
-0.16
<TS 9
A 3
128 15 02C 0.79
<TS 10 A
3 164 14 03H
-0.42
<TS 11 A
3 164 13 02C 0.82
<TS 12 A
4 55 14 DBC 0.4
<TS 13 A
4 115 13 04C 0.81
<TS 14 A
4 137 14 02C 0.78
<TS 15 A
4 157 12 02C 0.78
<TS 16 A
4 157 9
02C
-0.11
<TS 17 A
5 130 12 02C 0.87
<TS 18 A
9 2
18 02C 0.07
<TS 19 A
9 32 14 DBC 1.03
<TS 20 A
10 165 17 DBH 1.75
<TS 21 A
11 146 11 03C 0.82
<TS 22 A
12 3
16 02C 0.77
<TS 23 A
12 123 12 DBH 1.41
<TS 24 A
13 2
10 02H
-0.91
<TS 25 A
13 2
18 02H 0.97
<TS 26 A
13 34 17 03C
-1.01
<TS 27 A
13 146 15 DBC
-0.89
<TS 28 A
14 3
25 02C 0.78
<TS 29 A
15 154 11 DBC 1.58
<TS 30 A
18 49 10 VS4
-1.01
<TS 31 A
18 51 15 VS4
-1.05
<TS 32 A
19 56 17 DBC 0.84
<TS 33 A
20 3
14 02C
-0.74
<TS 34 A
21 2
13 04H 0.86
<TS 35 A
21 64 14 DBH
-1.66
<TS 36 A
21 114 12 02H 0.15
<TS 37 A
22 3
16 02C
-1.06
<TS 38 A
22 9
13 02C
-0.97
<TS 39 A
22 53 16 DBH 0.27
<TS 40 A
22 159 16 02H 0.92
<TS 41 A
22 163 13 02H
-0.81
<TS 42 A
23 4
14 02C
-0.87
<TS 43 A
24 33 9
01H 0.84
<TS 44 A
24 161 11 02C
-0.98
<TS 45 A
24 161 15 02C 0.82
<TS 46 A
24 163 18 02C 0.82
<TS 47 A
25 110 15 04C 0.82
<TS 48 A
26 3
19 02C
-1.03
<TS Page C-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 49 A
26 5
14 02H
-0.9
<TS 50 A
26 5
15 02H
-0.13
<TS 51 A
26 121 18 VS4
-0.52
<TS 52 A
26 161 13 03H 0.79
<TS 53 A
26 163 17 01H 0.95
<TS 54 A
27 6
9 02H
-0.72
<TS 55 A
27 8
14 02C
-0.87
<TS 56 A
27 10 9
05H
-0.06
<TS 57 A
27 10 10 05H 1.1
<TS 58 A
28 3
15 02C
-0.94
<TS 59 A
28 19 22 VS4
-0.94
<TS 60 A
28 31 22 VS4
-0.94
<TS 61 A
28 63 17 VS4
-1.07
<TS 62 A
29 122 11 02H 0.87
<TS 63 A
29 162 13 01H
-0.71
<TS 64 A
30 59 10 04C 0.74
<TS 65 A
31 4
13 02H
-0.85
<TS 66 A
31 44 12 02C 0.81
<TS 67 A
31 126 20 VS4
-0.65
<TS 68 A
31 126 10 VS4 0.3
<TS 69 A
31 128 17 VS4
-0.74
<TS 70 A
31 128 21 VS4 1.02
<TS 71 A
32 7
21 02C
-0.97
<:TS 72 A
32 37 7
03H.
0.13
<TS 73 A
32 37 13 03H 0.92
<TS 74 A
32 59 18 DBH 0
<TS 75 A
32 109 12 VS4
-0.26
<TS 76 A
32 145 19 VS4
-0.98
<TS 77 A
32 161 13 03H
-0.11
<TS 78 A
33 22 19 DBH 1.85
<TS 79 A
33 46 16 02H 0.97
<TS 80 A
33 116 13 03H 0.89
<TS 81 A
33 124 9
VS4 0.96
<TS 82 A
33 124 12 03C 0.82
<TS 83 A
34 15 11 VS4
-0.92
<TS 84 A
34 39 12 02H 1.08
<TS 85 A
34 57 11 04H 0.96
<TS 86 A
34 59 10 04H
-0.06
<TS 87 A
34 59 11 04H 0.88
<TS 88 A
34 63 15 DBC 1.72
<TS 89 A
34 109 14 04H 0.96
<TS 90 A
34 117 15 03C
-0.96
<TS 91 A
34 119 13 03H 1
<TS 92 A
34 121 14 03C 0.84
<TS 93 A
34 131 13 05C
-0.2
<TS 94 A
35 114 14 DBC 1.74
<TS 95 A
36 109 8
VS4
-0.04
<TS 96 A
36 117 13 03C 0.11
<TS 97 A
37 6
14 02C 0.89
<TS 98 A
37 6
15 02C
-0.87
<TS 99 A
37 24 15 05C 0.84
<TS 100 A
37 30 8
05H
-0.93
<TS Page C-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 101 A
37 30 8
05H 0.92
<TS 102 A
37 34 20 DBC 1.5
<TS 103 A
37 34 14.
04H 0.98
<TS 104 A
37 36 16 04H
-0.09
<TS 105 A
37 38 18 03C 0.83
<TS 106 A
37 50 6
04H
-0.92
<TS 107 A
37 50 14 04H 0.96
<TS 108 A
37 56 21 04H 0.96
<TS 109 A
37 62 23 04H 0.94
<TS 110 A
37 62 17 05H
-0.69
<TS 111 A
37 106 14 03C
-0.88
<TS 112 A
37 116 16 03C 0.75
<TS 113 A
37 128 23 VS4 1
<TS 114 A
37 128 15 VS4
-0.74
<TS 115 A
38 11 12 05H 0.93
<TS 116 A
38 17 18 05H
-0.04
<TS 117 A
38 35 19 05H 0.91
<TS 118 A
38 35 25 04H 0.87
<TS 119 A
38 35 22 03H 0.91
<TS 120 A
38 45 17 03C
-1
<TS 121 A
38 47 14 02H 0.87
<TS 122 A
38 51 31 04C 0.79
<TS 123 A
38 61 13 04H
-0.11
<TS 124 A
38 115 15 02C 0.83
<TS 125 A
38 119 12 02C 0.68
<TS 126 A
38 127 15 03H 0.91
<TS 127 A
39 10 14 DBH 1.59
<TS 128 A
39 14 13 05H
-0.06
<TS 129 A
39 40 11 02H 0.91
<TS 130 A
39 42 12 04H
-0.8
<TS 131 A
39 42 17 03C
-0.9
<TS 132 A
39 46 13 04H
-0.7
<TS 133 A
39 62 11 05H 0.24
<TS 134 A
39 62 15 05H 1
<TS 135 A
39 112 16 02C 0.72
<TS 136 A
39 120 20 04H 0.83
<TS 137 A
39 126 18 03C 0.82
<TS 138 A
39 130 12 DBC
-1.66
<TS 139 A
40 5
10 01C
-0.93
<TS 140 A
40 7
13 02C 0.82
<TS 141 A
40 35 10 04H 0.87
<TS 142 A
40 49 13 04H 0.9
<TS 143 A
40 59 17 05H 1.08
<TS 144 A
40 115 11 02C 0.78
<TS 145 A
40 125 11 02C 0.8
<TS 146 A
40 147 24 VS4
-0.13
<TS 147 A
40 147 24 VS4
-0.72
<TS 148 A
41 6
15 02C
-0.22
<TS 149 A
41 8
10 02C
-0.2
<TS 150 A
41 16 16 05H
-0.94
<TS 151 A
41 20 14 05H 1.09
<TS 152 A
41 22 9
05H
-0.96
<TS Page C-3
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 153 A
41 34 17 03H
-0.8
<TS 154 A
41 52 26 VS4
-0.71
<TS 155 A
41 60 25 05H 0.92
<TS 156 A
41 108 12 03C 0.82
<TS 157 A
41 126 10 02C
-0.88
<TS 158 A
41 160 18 01H 0.88
<TS 159 A
41 160 9
03C 0.67
<TS 160 A
41 160 13 03C
-0.18
<TS 161 A
42 5
15 02H 0.9
<TS 162 A
42 5
11 VS4
-0.72
<TS 163 A
42 5
10 VS4
-0.02
<TS 164 A
42 7
22 02C 0.81
<TS 165 A
42 7
12 02C 0.02
<TS 166 A
42 35 15 05C 0.97
<TS 167 A
42 41 34 VS4
-0.95
<TS 168 A
42 41 29 VS4 0.95
<TS 169 A
42 43 20 04H 0.86
<TS 170 A
42 45 13 02H 0.99
<TS 171 A
42 45 10 04H 0.96
<TS 172 A
42 59 14 04H 0.88
<TS 173 A
42 117 16 02C 0.74
<TS 174 A
43 44 13 04C 0.68
<TS 175 A
43 46 18 03H
-0.46
<TS 176 A
43 46 33 VS4
-0.66
<TS 177 A
43 46 18 VS4 1.09
<TS 178 A
43 106 13 03C 0.9
<TS 179 A
43 126 31 VS4 0.98
<TS 180 A
44 15 19 DBH
-1.58
<TS 181 A
44 21 28 VS4
-0.88
<TS 182 A
44 21 23 VS4
-0.25
<TS 183 A
44 21 27 VS4 0.7
<TS 184 A
44 49 20 04H 0.94
<TS 185 A
44 49 31 VS4
-0.75
<TS 186 A
44 49 27 VS4
-0.02
<TS 187 A
44 49 23 05C
-0.98
<TS 188 A
44 109 15 03C 0.09
<TS 189 A
44 123 16 06H
-0.07
<TS 190 A
44 123 19 VS4
-0.59
<TS 191 A
44 123 20 VS4 0.04
<TS 192 A
44 123 11 VS4 0.89
<TS 193 A
44 125 9
VS4
-0.48
<TS 194 A
45 12 17 DBH 1.78
<TS 195 A
45 30 14 04H
-0.85
<TS 196 A
45 30 7
04H 0.02
<TS 197 A
45 42 13 VS4 0.82
<TS 198 A
45 60 13 04H 0.98
<TS 199 A
45 108 17 03C 0.75
<TS 200 A
45 122 15 03C
-0.82
<TS 201 A
45 124 20 VS4 0.76
<TS 202 A
45 134 18 03C 0.6
<TS 203 A
46 37 14 03H 0.9
<TS 204 A
46 41 12 04H 0.85
<TS Page C-4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 205 A
46 47 15 02H 0.99
<TS 206 A
46 53 27 VS4
-0.87
<TS 207 A
46 53 23 VS4 0.98
<TS 208 A
46 55 13 VS4
-0.96
<TS 209 A
46 55 20 VS4 0.96
<TS 210 A
46 65 30 VS4 0.99
<TS 211 A
46 69 20 VS4
-0.42
<TS 212 A
46 125 22 VS4 0.04
<TS 213 A
46 125 11 VS4 0.83
<TS 214 A
46 127 11 02C 0.78
<TS 215 A
46 141 18 04C 0.83
<TS 216 A
47 8
18 01H
-0.8
<TS 217 A
47 12 12 DBC 1.66
<TS 218 A
47 24 12 04H
-0.82
<TS 219 A
47 34 11 03C 0.85
<TS 220 A
47 50 16 VS4 0.99
<TS 221 A
47 70 16 04H 0.95
<TS 222 A
47 112 17 02C 0.87
<TS 223 A
47 122 32 VS4 0.92
<TS 224 A
47 122 26 VS4 0.18
<TS 225 A
47 124 24 VS4 0.88
<TS 226 A
47 124 23 VS4 0.07
<TS 227 A
47 124 11 VS4
-0.57
<TS 228 A
47 126 13 04C
-0.02
<TS 229 A
47 126 26 VS4
-0.02
<TS 230 A
47 126 26 VS4
-0.81
<TS 231 A
48 7
24 01C 0.73
<TS 232 A
48 19 12 05H
-0.73
<TS 233 A
48 19 38 VS4
-1.11
<TS 234 A
48 19 29 VS4 0.69
<TS 235 A
48 21 27 VS4
-0.86
<TS 236 A
48 29 18 03C 0.83
<TS 237 A
48 29 17 04H 0.88
<TS 238 A
48 37 9
06H 0.98
<TS 239 A
48 41 38 VS4
-1.06
<TS 240 A
48 41 19 VS4 0.93
<TS 241 A
48 43 36 VS4
-1.02
<TS 242 A
48 43 17 VS4 0.79
<TS 243 A
48 43 9
VS4 0.2
<TS 244 A
48 55 13 04H 0.98
<TS 245 A
48 69 11 VS4
-0.89
<TS 246 A
48 69 36 VS4 0.98
<TS 247 A
48 97 30 VS4 0.88
<TS 248 A
48 111 13 02C 0.7
<TS 249 A
48 123 9
04C 0.8
<TS 250 A
48 125 16 02C 0.09
<TS 251 A
48 125 15 02C 0.78
<TS 252 A
48 159 14 01H
-0.14
<TS 253 A
48 159 9
01H 0.93
<TS 254 A
48 159 7
01H
-0.81
<TS 255 A
49 10 18 VS4 0.99
<TS 256 A
49 20 30 VS4
-0.81
<TS Page C-5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 257 A
49 20 25 VS4 1.04
<TS 258 A
49 24 11 VS4
-0.88
<TS 259 A
49 28 15 03C 0.79
<TS 260 A
49 36 14 03C 0.79
<TS 261 A
49 66 22 VS4 0.16
<TS 262 A
49 66 16 VS4 1.05
<TS 263 A
49 66 9
VS4
-0.66
<TS 264 A
49 70 22 VS4 1.02
<TS 265 A
49 70 11 DBC 1.57
<TS 266 A
49 74 20 VS4
-0.78
<TS 267 A
49 74 13 DBC 1.7
<TS 268 A
49 92 16 03C
-0.96
<TS 269 A
49 112 21 VS4
-0.13
<TS 270 A
49 112 13 VS4
-0.57
<TS 271 A
49 122 7
04C 0.8
<TS 272 A
49 122 9
04C
-0.88
<TS 273 A
50 17 11 VS4
-0.98
<TS 274 A
50 19 14 VS4 0.76
<TS 275 A
50 19 9
DBC 1.59
<TS 276 A
50 21 17 DBH 1.63
<TS 277 A
50 21 11 DBC 1.58
<TS 278 A
50 45 13 03H 0.89
<TS 279 A
50 45 15 VS5
-0.86
<TS 280 A
50 57 12 04H 0.98
<TS 281 A
50
. 91 14 VS4 0.83
<TS 282 A
50 123 19 04C 0.02
<TS 283 A
50 127 12 03C
-0.89
<TS 284 A
50 127 8
03C 0.11
<TS 285 A
50 157 37 VS3
-0.85
<TS 286 A
50 157 21 VS3 0.8
<TS 287 A
51 16 18 VS4
-0.74
<TS 288 A
51 20 31 VS3
-0.78
<TS 289 A
51 20 15 VS5
-0.18
<TS 290 A
51 54 13 04H 0.87
<TS 291 A
51 70 15 05H 0.9
<TS 292 A
51 108 13 03C
-0.83
<TS 293 A
51 118 16 02C
-0.95
<TS 294 A
51 122 16 02C
-0.22
<TS 295 A
51 124 13 04C
-0.92
<TS 296 A
51 126 18 02C 0.07
<TS 297 A
51 126 12 02C 0.81
<TS 298 A
51 126 14 03C
-0.87
<TS 299 A
51 134 10 04C 0.78
<TS 300 A
51 134 9
04C 0.07
<TS 301 A
51 134 13 VS3
-0.77
<TS 302 A
52 9
11 01C
-0.93
<TS 303 A
52 25 9
04H 0.97
<TS 304 A
52 33 13 06H 0.92
<TS 305 A
52 53 13 03H 0.82
<TS 306 A
52 111 20 02C 0.81
<TS 307 A
52 117 21 02C 0.8
<TS 308 A
52 149 16 VS3 1.11
<TS Page C-6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 309 A
52 149 13 VS4
-0.93
<TS 310 A
53 10 12 01H
-0.83
<TS 311 A
53 10 8
VS4
-0.83
<TS 312 A
53 10 8
01C
-0.24
<TS 313 A
53 10 14 01C
-0.97
<TS 314 A
53 24 7
DBH
-1.52
<TS 315 A
53 88 14 03C
-0.91
<TS 316 A
53 92 17 03C 0.73
<TS 317 A
53 118 14 02C 0.8
<TS 318 A
53 122 9
04C 0.82
<TS 319 A
53 122 19 02C
-0.24
<TS 320 A
53 122 6
04C
-0.99
<TS 321 A
54 21 9
DBC 1.51
<TS 322 A
54 29 17 02C 0.7
<TS 323 A
54 33 8
03H 0.9
<TS 324 A
54 39 14 03H 0.97
<TS 325 A
54 77 12 DBC
-1.61
<TS 326 A
54 81 20 DBH 1.89
<TS 327 A
54 83 17 03H 0.93
<TS 328 A
54 83 29 DBH 0.13
<TS 329 A
54 109 14 04C 0.84
<TS 330 A
54 119 15 02C 0.76
<TS 331 A
54 139 10 DBC 1.73
<TS 332 A
55 8
17 01C
-0.28
<TS 333 A
55 46 13 04H
-0.7
<TS 334 A
55 88 15 02C
-1
<TS 335 A
55 120 15 02C
-0.24
<TS 336 A
55 122 17 02C
-0.22
<TS 337 A
55 140 23 06C
-0.18
<TS 338 A
56 27 9
03H
-0.83
<TS 339 A
56 39 14 04H
-0.02
<TS 340 A
56 81 18 DBH 1.75
<TS 341 A
56 115 17 02C 0.82
<TS 342 A
56 115 11 03C
-0.95
<TS 343 A
56 137 16 03C 0.09
<TS 344 A
57 10 12 01C
-0.22
<TS 345 A
57 18 14 VS3
-0.63
<TS 346 A
57 32 9
06H 0
<TS 347 A
57 110 15 02C 0.81
<TS 348 A
57 114 11 03C
-0.95
<TS 349 A
57 142 14 03C 0.84
<TS 350 A
58 33 10 04H
-0.81
<TS 351 A
58 33 10 DBH 1.74
<TS 352 A
58 81 10 03H
-0.08
<TS 353 A
58 85 14 03H 1.01
<TS 354 A
58 121 14 02C 0.87
<TS 355 A
58 123 13 03C 0
<TS 356 A
58 127 25 04C 0.76
<TS 357 A
59 30 17 03C 0.77
<TS 358 A
59 38 15 03H 0.85
<TS 359 A
59 56 12 DBH
-0.81
<TS 360 A
59 106 15 02C 1.02
<TS Page C-7
A Document No.: 51~9252894-001
.AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 361 A
59 114 13 03C 0.81
<TS 362 A
59 114 12 03C
-0.94
<TS 363 A
59 126 12 06H 0.91
<TS 364 A
60 11 14 01C 0
<TS 365 A
60 25 13 04H 0.86
<TS 366 A
60 29 20 04H 0.87
<TS 367 A
60 33 15 DBC 1.49
<TS 368 A
60 39 7
05H
-0.02
<TS 369 A
60 39 11 06H 0.97
<TS 370 A
60 39 14 04H 0.9
<TS 371 A
60 119 20 02C 0.82
<TS 372 A
60 121 17 02C 0.8
<TS 373 A
61 20 9
DBC 1.58
<TS 374 A
61 34 14 03H 0.97
<TS 375 A
61 34 11 04H 0.87
<TS 376 A
61 36 9
03H
-0.8
<TS 377 A
61 40 12 04H 0.91
<TS 378 A
61 44 14 04H
-0.13
<TS 379 A
61 80 9
06H
-0.02
<TS 380 A
61 112 14 04C
-1.03
<TS 381 A
61 138 13 DBC 1.22
<TS 382 A
61 144 11 DBH 1.82
<TS 383 A
61 150 11 DBC 1.3
<TS 384 A
62 11 13 01C
-0.98
<TS 385 A
62 15 9
06C 0.74
<TS 386 A
62 19 14 06H 0.95
<TS 387 A
62 33 17 03H 0.95
<TS 388 A
62 35 11 03H 0.9
<TS 389 A
62 49 12 05H 0.93
<TS 390 A
62 73 11 04H
-0.02
<TS 391 A
63 12 14 01C
-0.97
<TS 392 A
63 40 9
DBC
-1.39
<TS 393 A
63 44 12 06C
-0.96
<TS 394 A
63 52 15 06C 0.78
<TS 395 A
63 58 11 03H 0.96
<TS 396 A
63 66 12 04H
-0.89
<TS 397 A
63 80 8
03H 1.05
<TS 398 A
63 80 6
03H
-0.85
<TS 399 A
63 82 10 06H 0.99
<TS 400 A
63 82 20 03H 0.92
<TS 401 A
63 82 7
02H
-0.87
<TS 402 A
63 84 12 DBH
-1.9
<TS 403 A
63 104 15 03C 0.77
<TS 404 A
63 118 16 03C 0.83
<TS 405 A
63 122 17 03C 0.74
<TS 406 A
63 124 15 04C 0.81
<TS 407 A
63 124 10 04C
-0.11
<TS 408 A
63 126 16 04C 0.82
<TS 409 A
63 134 13 03C 0.77
<TS 410 A
63 136 15 06H
-0.21
<TS 411 A
63 140 18 DBC 1.47
<TS 412 A
63 142 13 04C 0.77
<TS Page C-8
A Docum~nt No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 413 A
64 11 15 VS5 0.73
<TS 414 A
64 11 9
VS4 0.62
<TS 415 A
64 11 29 VS4
-0.94
<TS 416 A
64 11 11 06H 0.87
<TS 417 A
64 13 14 04H 0.88
<TS 418 A
64 13 16 VS4
-0.91
<TS 419 A
64 25 12 06C 0.97
<TS 420 A
64 29 15 DBC 1.68
<TS 421 A
64 37 18 VS5 0.89
<TS 422 A
64 57 13 06C 0.82
<TS 423 A
64 57 11 05H 0.97
<TS 424 A
64 59 11 04C 0.81
<TS 425 A
64 59 13 05C 0.73
<TS 426 A
64 71 9
VS5
-0.88
<TS 427 A
64 71 9
VS5 0.9
<TS 428 A
64 83 10 03H 0.96
<TS 429 A
64 123 17 04C 0.78
<TS 430 A
64 139 13 03C 0.96
<TS 431 A
64 153 11 01C
-1.03
<TS 432 A
65 12 18 06H 0.91
<TS 433 A
65 12 9
01C
-0.23
<TS 434 A
65 14 9
06H 0.95
<TS 435 A
65 16 10 05H 0.84
<TS 436 A
65 24 9
VS5
-0.86
<TS 437 A
65 24 11 VS5 0.68
<TS 438 A
65 32 7
04H 0.88
<TS 439 A
65 32 9
DBC 1.35
<TS 440 A
65 32 6
DBC
-1.26
<TS 441 A
65 40 14 03H 0.97
<TS 442 A
65 76 10 02H
-0.05
<TS 443 A
65 90 16 02C 0.85
<TS 444 A
65 106 19 04C 0.75
<TS 445 A
65 108 16 03H
-0.88
<TS 446 A
65 116 13 VS3 0.9
<TS 447 A
65 126 16 06C
-1.04
<TS 448 A
65 138 27 04C
-0.21
<TS 449 A
65 152 21 VS3 0.98
<TS 450 A
66 13 11 01C
-1.09
<TS 451 A
66 13 11 VS4
-0.8
<TS 452 A
66 25 11 04H 0.89
<TS 453 A
66 27 19 06C 0.79
<TS 454 A
66 31 9
05H
-0.86
<TS 455 A
66 31 16 04H 0.95
<TS 456 A
66 35 13 04H 0.86
<TS 457 A
. 66 37 10 06H 0.07
<TS 458 A
66 39 7
05H 0.93
<TS 459 A
66 55 10 02H 0.85
<TS 460 A
66 59 14 06C 0.81
<TS 461 A
66 75 10 05H 0.93
<TS 462 A
66 77 5
DBC
-1.78
<TS 463 A
66 79 10 01H
-0.14
<TS 464 A
66 79 9
03H
-0.71
<TS Page C-9
- --- ------------------~----
~
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 465 A
66 83 14 06C 0.8
<TS 466 A
66 107 13 03H 0.11
<TS 467 A
66 107 13 02C
-0.99
<TS 468 A
66 109 13 03H
-0.77
<TS 469 A
66 109 13 04C 0.83
<TS 470 A
66 109 13 04C 0.07
<TS 471 A
66 109 17 02C 0.78
<TS 472 A
66 113 12 02C 0.79
<TS 473 A
66 113 14 03H 0.92
<TS 474 A
66 137 12 06C
-0.86
<TS 475 A
67 12 10 03H 0.83
<TS 476 A
67 14 25 05H 0.87
<TS 477 A
67 20 16 VS5 0.69
<TS 478 A
67 24 24 06H 0.93
<TS 479 A
67 24 7
06H 0.17
<TS 480 A
67 32 11 06H 1.04
<TS 481 A
67 34 10 06C 0.84
<TS 482 A
67 38 5
06H
-0.11
<TS 483 A
67 38 10 06H 1.04
<TS 484 A
67 50 12 03C 0.79
<TS 485 A
67 50 8
03C 0.02
<TS 486 A
67 56 11 VS3 0.73
<TS 487 A
67 106 10 02H 0.98
<TS 488 A
67 106 14 03H 0.88
<TS 489 A
67 112 10 VS3 0.86
<TS 490 A
67 114 25 02C 0.85
<TS 491 A
67 118 12 03C 0.85
<TS 492 A
67 120 12 06H
-0.06
<TS 493 A
67 120 15 VS5 1.01
<TS 494 A
67 120 11 06H 1.08
<TS 495 A
67 130 14 DBH 1.87
<TS 496 A
67 136 20 VS3 0.61
<TS 497 A
67 138 11 03C 0.72
<TS 498 A
67 154 17 02C 0.86
<TS 499 A
67 154 18 01C
-0.61
<TS 500 A
67 154 12 04C 0.83
<TS 501 A
68 15 8
05H
-0.09
<TS 502 A
68 17 11 VS4 0.84
<TS 503 A
68 17 5
VS4
-0.89
<TS 504 A
68 17 14 VS3
-0.62
<TS 505 A
68 21 11 VS3
-0.81
<TS 506 A
68 21 20 VS4
-0.87
<TS 507 A
68 21 23 VS4 0.94
<TS 508 A
68 21 18 VS5 0.24
<TS 509 A
68 21 15 VS5 1
<TS 510 A
68 27 10 VS3
-0.69
<TS 511 A
68 39 10 VS3 0.94
<TS 512 A
68 41 13 04H 0.95
<TS 513 A
68 45 16 06H 0.97
<TS 514 A
68 53 13 04H
-0.17
<TS 515 A
68 81 17 03H 0.89
<TS 516 A
68 107 10 03H
-0.06
<TS Page C-10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 517 A
68 139 31 VS3
-0.68
<TS 518 A
68 139 12 VS5
-0.61
<TS 519 A
68 139 31 VS5 0.79
<TS 520 A
68 141 14 DBH 1.77
<TS 521 A
69 22 21 VS3 0.86
<TS 522 A
69 22 26 VS4
-0.93
<TS 523 A
69 22 19 VS4
-0.09
<TS 524 A
69 22 30 VS4 0.8
<TS 525 A
69 22 26 VS5 0.78
<TS 526 A
69 30 14 DBC 1.69
<TS 527 A
69 34 15 DBH 1.71
<TS 528 A
69 34 12 06C 0.8
<TS 529 A
69 40 14 04H 0.97
<TS 530 A
69 40 14 DBH 1.81
<TS 531 A
69 54 16 03C
-1.05
<TS 532 A
69 58 10 02C 0.83
<TS 533 A
69 60 10 06H 0.86
<TS 534 A
69 108 17 04H 1
<TS 535 A
69 126 12 DBC 1.69
<TS 536 A
69 134 18 06C
-1.1
<TS 537 A
69 136 12 VS3
-0.9
<TS 538 A
69 136 13 VS5 0.55
<TS 539 A
69 152 24 VS3
-0.85
<TS 540 A
69 152 24 VS3 0.94
<TS 541 A
70 15 12 VS4
-0.83
<TS 542 A
70 19 11 05H 0.94
<TS 543 A
70 29 7
DBC 1.6
<TS 544 A
70 53 19 03C 0
<TS 545 A
70 53 10 02C
-0.91
<TS 546 A
70 55 18 03C
-0.93
<TS 547 A
70 69 14 05H
-0.02
<TS 548 A
70 81 17 DBC 1.7
<TS 549 A
70 81 10 03H 0.93
<TS 550 A
70 107 11 04H 0.13
<TS 551 A
70 107 14 04C
-0.88
<TS 552 A
70 115 15 DBH 1.81
<TS 553 A
70 119 13 04C 0.86
<TS 554 A
70 129 11 DBC 1.71
<TS 555 A
70 137 16 06H 0.96
<TS 556 A
70 143 18 DBH 1.83
<TS 557 A
70 145 10 DBC
-1.9
<TS 558 A
70 153 22 VS3
-0.91
<TS 559 A
70 153 14 VS3 0.91
<TS 560 A
70 153 15 DBH
-1.63
<TS 561 A
70 153 11 02C
-0.83
<TS 562 A
71 34 7
03H
-0.79
<TS 563 A
71 54 11 04H 1.03
<TS 564 A
71 78 15 06C
-0.93
<TS 565 A
71 108 13 05C 0.81
<TS 566 A
71 108 15 02C
-0.24
<TS 567 A
71 110 12 04H 0.91
<TS 568 A
71 126 19 05C 0.86
<TS Page C-11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 569 A
71 126 9
05C 0.09
<TS 570 A
71 134 15 VS3
-0.72
<TS 571 A
71 150 13 06H 0.91
<TS 572 A
72 29 7
DBC 1.84
<TS 573 A
72 47 13 04C
-0.22
<TS 574 A
72 53 9
04C 0.87
<TS 575 A
72 53 14 04C
-1.14
<TS 576 A
72 53 13 02C 0.86
<TS 577 A
72 55 14 04C
-0.13
<TS 578 A
72 55 16 03C
-0.99
<TS 579 A
72 85 14 05C 0.02
<TS 580 A
72 127 13 VS4
-0.17
<TS 581 A
72 127 17 04C 0.7
<TS 582 A
72 143 15 DBC 1.59
<TS 583 A
72 145 12 DBH 1.68
<TS 584 A
72 149 18 DBH 1.61
<TS 585 A
72 151 12 01H
-0.11
<TS 586 A
73 14 14 VS4 0.98
<TS 587 A
73 14 17 VS4
-0.98
<TS 588 A
73 14 10 03H 0.94
<TS 589 A
73 14 13 05H
-0.88
<TS 590 A
73 44
- 19 06C
-0.95
<TS 591 A
73 66 13 04C 0.72
<TS 592 A
73 152 12 VS3
-0.83
<TS 593 A
73 152 13 VS3 0.98
<TS 594 A
74 15 19 VS4 0.74
<TS 595 A
74 15 10 01C
-0.96
<TS 596 A
74
. 19 14 DBC 1.6
<TS 597 A
74 33 10 DBC 1.26
<TS 598 A
74 79 12 05C
-1
<TS 599 A
74 145 13 DBC 1.34
<TS 600 A
74 149 12 DBC 1.18
<TS 601 A
75 16 19 06C 0
<TS 602 A
75 16 28 VS5
-0.94
<TS 603 A
75 16 17 03H 0.53
<TS 604 A
75 20 15 03H 0.89
<TS 605 A
75 20 12 04H
-0.8
<TS 606 A
75 28 12 DBH 1.71
<TS 607 A
75 32 17 DBH 1.71
<TS 608 A
75 44 36 VS3
-0.7
<TS 609 A
75 44 20 VS3 1.03
<TS 610 A
75 50 18 VS3 0.91
<TS 611 A
75 50 22 VS3
-0.8
<TS 612 A
75 56 13 03C 0.75
<TS 613 A
75 68 16 02C 0.83
<TS 614 A
75 76 11 02H
-0.96
<TS 615 A
75 76 11 02H 0.92
<TS 616 A
75 82 11 03H 0.96
<TS 617 A
75 92 14 06H
-0.62
<TS 618 A
75 110 11 DBC
-1.53
<TS 619 A
75 120 17 03C 0.78
<TS 620 A
75 148 10 06C 0.76
<TS Page C-12
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 621 A
76 15 15 01C 0
<TS 622 A
76 15 34 DBC
-1.69
<TS 623 A
76 15 11 DBC 1.8
<TS 624 A
76 15 10 04H
-0.89
<TS 625 A
76 15 10 03H
-0.18
<TS 626 A
76 15 10 06C 0.82
<TS 627 A
76 17 17 DBC 1.76
<TS 628 A
76 19 10 DBC 1.62
<TS 629 A
76 21 12 03H 0.85
<TS 630 A
76 21 13 04H 0.91
<TS 631 A
76 37 10 06H
-0.04
<TS 632 A
76 51 9
04C
. 0.04
<TS 633 A
76 51 15 VS4 0.89
<TS 634 A
76 51 12 VS3 1
<TS 635 A
76 51 11 VS3
-0.78
<TS 636 A
76 53 14 03C 0.87
<TS 637 A
76 55 23 03C 0.81
<TS 638 A
76 57 12 05C
-0.91
<TS 639 A
76 57 12 02C 0.68
<TS 640 A
76 69 11 04H
-0.07
<TS 641 A
76 91 17 02C 0.83
<TS 642 A
76 97 11 04C 0.89
<TS 643 A
76 97 12 04C
-0.91
<TS 644 A
76 101 18 02H
-0.88
<TS 645 A
76 101 17 03H 0.85
<TS 646 A
76 103 13 03H
-0.06
<TS 647 A
76 111 14 04C 0.79
<TS 648 A
77 16 29 VS4
-0.81
<TS 649 A
77 16 14 DBC 1.93
<TS 650 A
77 18 13 06H
-0.64
<TS 651 A
77 18 16 05H
-0.83
<TS 652 A
77 18 11 07C
-0.02
<TS 653 A
77 20 10 06H
-0.09
<TS 654 A
77 20 8
DBC
-1.21
<TS 655 A
77 22 10 03H 0.92
<TS 656 A
77 22 13 06H 0.99
<TS 657 A
77 24 10 03H 1
<TS 658 A
77 24 9
04H
-0.06
<TS 659 A
77 24 12 06H 0.99
<TS 660 A
77 28 13 06H 0.91
<TS 661 A
77 44 18 VS3 0.93
<TS 662 A
77 44 13 VS4 0.13
<TS 663 A
77 44 25 VS5 0.93
<TS 664 A
77 52 11 02C 0.74
<TS 665 A
77 52 11 03C
-0.98
<TS 666 A
77 52 13 06C
-0.94
<TS 667 A
77 62 15 03C 0.84
<TS 668 A
77 68 9
02H 0.94
<TS 669 A
77 76 11 VS5 0.95
<TS 670 A
77 82 12 05C 0.79
<TS 671 A
77 92 15 02C
-1
<TS 672 A
77 102 15 03H 0.87
<TS Page C-13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 673 A
77 122 19 06C 0.74
<TS 674 A
77 148 17 07H
-0.97
<TS 675 A
77 148 22 03C 0.8
<TS 676 A
78 17 17 DBH
-1.55
<TS 677 A
78 19 13 DBC
-1.62
<TS 678 A
78 25 11 DBC
-1.59
<TS 679 A
78 25 11 05C
-0.9
<TS 680 A
78 75 10 02H 0.14
<TS 681 A
78 101 14 03H 0.95
<TS 682 A
78 113 18 02C 0.76
<TS 683 A
78 149 12 DBC
-1.29
<TS 684 A
79 16 12 DBH
-1.67
<TS 685 A
79 18 14 VS4
-0.82
<TS 686 A
79 18 7
VS4 1.06
<TS 687 A
79 18 13 DBC 1.45
<TS 688 A
79 20 11 05H 0.94
<TS 689 A
79 22 11 07C 0.84
<TS 690 A
79 68 15 07H 0.97
<TS 691 A
79 68 12 04C
-0.91
<TS 692 A
79 72 14 04H 0.91
<TS 693 A
79 72 15 VS3 0
<TS 694 A
79 82 17 03H 0.91
<TS 695 A
79 90 17 04C
-0.15
<TS 696 A
79 94 11 03C
-1.03
<TS 697 A
79 100 14 03H 0.95
<TS 698 A
79 104 14 05H 0.96
<TS 699 A
79 128 21 04C 0.7
<TS 700 A
79 144 12 VS5
-0.77
<TS 701 A
79 144 23 VS5 1.01
<TS 702 A
79 148 10 02C 0.84
<TS 703 A
79 150 19 VS4 1.08
<TS 704 A
79 150 13 02C 0.9
<TS 705 A
79 150 15 02C
-0.09
<TS 706 A
80 17 9
VS4 0.57
<TS 707 A
80 27 16 VS3 1
<TS 708 A
80 57 12 04H 0.11
<TS 709 A
80 57 17 04H 0.92
<TS 710 A
80 59 12 04C 0.75
<TS 711 A
80 65 12 04C 0.77
<TS 712 A
80 71 9
04H
-0.83
<TS 713 A
80 77 9
02H
-0.89
<TS 714 A
80 77 17 04H 0.98
<TS 715 A
80 99 12 07C 0.84
<TS 716 A
80 107 20 DBH 1.78
<TS 717 A
80 119 14 03C 0.79
<TS 718 A
80 143 12 05C 0.86
<TS 719 A
80 145 12 02C
-0.2
<TS 720 A
80 147 14 07H 0.82
<TS 721 A
80 149 18 VS4
-0.84
<TS 722 A
81 18 13 VS4
-0.73
<TS 723 A
81 18 10 DBC
-1.89
<TS 724 A
81 18 12 01H 0.98
<TS Page C-14
A Document No.: 51-9252894-001 A.REV.A Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 725 A
81 20 10 04H 0.88
<TS 726 A
81 20 7
04H
-0.15
<TS 727 A
81 22 7
-1.43
<TS 728 A
81 24 11 DSC
-1.43
<TS 729 A
81 46 16 VS3 0.04
<TS 730 A
81 46 16 VS3 0.84
<TS 731 A
81 46 21 VS5 0.88
<TS 732 A
81 54 17 05C
-1
<TS 733 A
81 70 12 VS4
-0.74
<TS 734 A
81 84 11 04C
-0.98
<TS 735 A
81 84 11 05C
-0.96
<TS 736 A
81 84 19 07C
-0.15
<TS 737 A
81 84 29 VS4 0.92
<TS 738 A
81 94 11 02C
-0.2
<TS 739 A
81 94 17 02C
-0.98
<TS 740 A
81 94 15 DSH 1.86
<TS 741 A
81 100 13 05H 0.88
<TS 742 A
81 102 10 07C
-0.22
<TS 743 A
81 102 17 07C
-0.96
<TS 744 A
81 118 10 VS3
-0.82
<TS 745 A
81 130 21 VS3
-0.69
<TS 746 A
81 130 20 VS3 0.07
<TS 747 A
81 148 17 02C 0.77
<TS 748 A
81 148 22 05C 0.02
<TS 749 A
82 19 7
VS4
-1.04
<TS 750 A
82 19 12 VS4 0.55
<TS 751 A
82 33 11 VS3 1.05
<TS 752 A
82 35 9
VS3 0.2
<TS 753 A
82 61 15 VS3
-0.74
<TS 754 A
82 71 11 VS3 0.97
<TS 755 A
82 89 18 05C 0.79
<TS 756 A
82 91 13 07C 0.85
<TS 757 A
82 101 8
05H
-0.02
<TS 758 A
82 101 10 DSH
-1.99
<TS 759 A
82 107 11 04H 0.87
<TS 760 A
82 121 11 05H 0.9
<TS 761 A
82 135 14 VS3
-0.92
<TS 762 A
82 141 19 VS3
-0.88
<TS 763 A
83 50 10 05C 0.73
<TS 764 A
83 76 14 02H 0.94
<TS 765 A
83 84 14 02C 0.85
<TS 766 A
83 88 17 04C 0.85
<TS 767 A
83 90 11 05H
-0.13
<TS 768 A
83 90 19 07H 0.92
<TS 769 A
83 100 20 04H 0.91
<TS 770 A
83 100 10 05H 0.91
<TS 771 A
83 102 15 05C
-0.18
<TS 772 A
83 102 13 05C
-0.88
<TS 773 A
83 114 10 VS2
-0.85
<TS 774 A
83 116 15 VS2
-0.3
<TS 775 A
83 122 13 VS2 0.82
<TS 776 A
83 130 11 VS2 0.77
<TS Page C-15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 777 A
83 136 11 DBH 1.76
<TS 778 A
83 146 14 04C
-0.85
<TS 779 A
83 148 15 VS4
-0.95
<TS 780 A
83 148 13 VS4
-0.62.
<TS 781 A
83 148 12 07C 0.82
<TS 782 A
83 148 20 03C
-0.9
<TS 783 A
84 19 17 VS5 0.99
<TS 784 A
84 19 22 VS4 0.8
<TS 785 A
84 19 22 VS4
-0.97
<TS 786 A
84 19 11 VS3 0.19
<TS 787 A
84 19 14 VS2 0.6
<TS 788 A
84 19 14 01H
-0.02
<TS 789 A
84 19 12 01H
-0.74
<TS 790 A
84 25 11 VS2 0.61
<TS 791 A
84 29 18 VS2 0.76
<TS 792 A
84 29 15 05C
-1.09
<TS 793 A
84 33 20 VS2
-0.83
<TS 794 A
84 37 16 VS2
-0.88
<TS 795 A
84 39 12 VS2
-0.8
<TS 796 A
84 39 17 VS3
-0.85
<TS 797 A
84 41 14 07H 0.99
<TS 798 A
84 45 11 VS6
-0.78
<TS 799 A
84 47 13 06H 0.95
<TS 800 A
84 51 14 DBH 1.67
<TS 801 A
84 51 10 VS2 0.65
<TS 802 A
84 53 23 VS2
-0.82
<TS 803 A
84 61 28 03C 0.86
<TS 804 A
84 73 13 04H 0.92
<TS 805 A
84 81 9
04H 0.95
<TS 806 A
84 85 18 04H 0.94
<TS 807 A
84 93 13 05C
-0.94
<TS 808 A
84 93 11 05C
-0.22
<TS 809 A
84 99 18 VS2
-0.84
<TS 810 A
84 125 14 04C
-1.02
<TS 811 A
84 141 20 04C 0.86
<TS 812 A
84 143 11 03C 0.88
<TS 813 A
84 147 12 VS5 0.93
<TS 814 A
85 20 24 VS4
-0.89
<TS 815 A
85 20 20 VS4 o.i1
<TS 816 A
85 26 16 03H 0.88
<TS 817 A
85 28 12 VS3
-0.69
<TS 818 A
85 32 10 VS5 1.05
<TS 819 A
85 32 10 03C
-1.01
<TS 820 A
85 40 9
VS5
-0.63
<TS 821 A
85 62 13 04C 0.77
<TS 822 A
85 74 13 05C
-1
<TS 823 A
85 84 13 05H 1.01
<TS 824 A
85 92 17 02C 0.85
<TS 825 A
85 104 19 03C 0.79
<TS 826 A
85 146 16 02C 0.71
<TS 827 A
85 146 23 03C
-0.99
<TS 828 A
86 21 12 VS4
-0.82
<TS Page C-16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 829 A
86 35 14 VS6
-0.7
<TS 830 A
86 55 13 06C 0.8
<TS 831 A
86 65 13 05H 0.99
<TS 832 A
86 69 13 06C
-0.96
<TS 833 A
86 81 12 02H
-0.74
<TS 834 A
86 97 18 03H 0.96
<TS 835 A
86 101 15 04H
-0.81
<TS 836 A
86 101 9
05C
-0.94
<TS 837 A
86 111 13 05C 0.85
<TS 838 A
86 145 17 04C 0.75
<TS 839 A
86 145 9
03C 0.85
<TS 840 A
86 145 11 03C
-0.92
<TS 841 A
86 145 12 02C 0.96
<TS 842 A
87 20 10 VS4
-0.93
<TS 843 A
87 20 16 VS4
-0.35
<TS 844 A
87 20 24 VS4 0.54
<TS 845 A
87 22 12 01H 0.91
<TS 846 A
87 22 14 04H 0.84
<TS 847 A
87 22 19 VS4
-0.94
<TS 848 A
87 36 13 DBH 1.75
<TS 849 A
87 36 10 07C 0.78
<TS 850 A
87 40 14 07H
-0.93
<TS 851 A
87 40 8
VS2
-0.94
<TS 852 A
87 56 9
05H 0.94
<TS 853 A
87 56 12 04C 0.79
<TS 854 A
87 58 14 VS2
-0.84
<TS 855 A
87 60 15 VS2
-0.74
<TS 856 A
87 82 13 05H 0.98
<TS 857 A
87 88 7
04H 0.28
<TS 858 A
87 90 12 04H 0.96
<TS 859 A
87 90 11 04H
-0.13
<TS 860 A
87 92 11 04H
-0.74
<TS 861 A
87 92 10 04H 0.94
<TS 862 A
87 92 15 05C 0.82
<TS 863 A
87 92 19 04C 0.81
<TS 864 A
87 100 18 04H 0.98
<TS 865 A
87 102 12 03H 0.77
<TS 866 A
87 102 11 04H
-0.04
<TS 867 A
87 102 21 05H 0.88
<TS 868 A
87 104 10 06H 0.94
<TS 869 A
87 106 8
06H 0.23
<TS 870 A
87 110 10 03H 0.75
<TS 871 A
87 112 13 04H 0.9
<TS 872 A
87 116 14 03C
-0.11
<TS 873 A
87 116 18 04C 0.83
<TS 874 A
87 120 11 VS2 0.04
<TS 875 A
87 120 16 VS2 0.69
<TS 876 A
87 124 12 04C
-1.11
<TS 877 A
87 142 9
03C
-0.96
<TS 878 A
87 144 21 03C
-0.9
<TS 879 A
87 144 14 04C 0.77
<TS 880 A
87 146 19 VS4
-0.95
<TS Page C-17
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 881 A
87 146 23 VS4 0.58
<TS 882 A
87 146 12 02C 0.77
<TS 883 A
88 21 24 VS4
-0.74
<TS 884 A
88 21 10 VS4 0.32
<TS 885 A
88 33 12 04H 0.91
<TS 886 A
88 53 18 VS4 1.01
<TS 887 A
88 53 22 07C 0.92
<TS 888 A
88 53 14 05C
-0.55
<TS 889 A
88 57 12 06H 0.9
<TS 890 A
88 57 13 VS6 0.73
<TS 891 A
88 57 20 07C 0.9
<TS 892 A
88 59 18 05C 0.8
<TS 893 A
88 59 16 05C 0.07
<TS 894 A
88 59 13 04C 0.59
<TS 895 A
88 61 20 02C 0.84
<TS 896 A
88 61 22 03C 0.44
<TS 897 A
88 73 17 02H
-0.09
<TS 898 A
88 81 11 02C 0.81
<TS 899 A
88 83 13 04H
-0.74
<TS 900 A
88 83 13 05H
-0.84
<TS 901 A
88 89 16 06H 0.94
<TS 902 A
88 91 16 04H 0.94
<TS 903 A
88 99 10 06H
-0.85
<TS 904 A
88 125 13 04C
-0.87
<TS 905 A
88 125 11 03C
-0.96
<TS 906 A
88 145 21 VS4 0.78
<TS 907 A
88 145 24 04C
-0.99
<TS 908 A
88 145 32 02C
-0.18
<TS 909 A
89 26 14 VS6 0.87
<TS 910 A
89 28 13 VS6 0.77
<TS 911 A
89 32 12 03C
-1.05
<TS 912 A
89 34 11 04H
-0.88
<TS 913 A
89 38 9
04H
-0.95
<TS 914 A
89 42 10 07H 0.92
<TS 915 A
89 54 12 07C 0.82
<TS 916 A
89 60 10 04H
-0.77
<TS 917 A
89 72 14 01C 0.74
<TS 918 A
89 78 8
07H
-0.81
<TS 919 A
89 78 17 07H 0.99
<TS 920 A
89 84 12 04H
-0.7
<TS 921 A
89 108 12 04H 1.04
<TS 922 A
89 108 13 05H 0.92
<TS 923 A
89 108 25 06H 0.87
<TS 924 A
89 112 12 05H 0.15
<TS 925 A
89 112 11 05H
-0.85
<TS 926 A
89 112 13 05H 0.91
<TS 927 A
89 128 14 03H 0.82
<TS 928 A
89 136 14 03H 0.91
<TS 929 A
90 23 11 VS4
-0.82
<TS 930 A
90 25 12 VS4 0.98
<TS 931 A
90 31 7
04H 0.9
<TS 932 A
90 35 8
05H 0.89
<TS Page C-18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 933 A
90 59 8
04H
-0.17
<TS 934 A
90 59 12 04H 0.93
<TS 935 A
90 79 7
05H 0.96
<TS 936 A
90 81 11 06H 0.91
<TS 937 A
90 87 14 02C 0.81
<TS 938 A
90 87 12 04C 0.44
<TS 939 A
90 87 17 06H 0.57
<TS 940 A
90 87 17 03H 0.95
<TS 941 A
90 91 11 03C 0.87
<TS 942 A
90 93 20 03C 0.72
<TS 943 A
90 93 14 04C 0.72
<TS 944 A
90 95 11 02C
-0.96
<TS 945 A
90 95 18 04C 0.85
<TS 946 A
90 95 17 06C 0.72
<TS 947 A
90 95 16 07C 0.13
<TS 948 A
90 101 14 02C 0.04
<TS 949 A
90 103 10 04H 0.91
<TS 950 A
90 105 22 05C 0.83
<TS 951 A
90 107 12 04H 0.99
<TS 952 A
90 107 13 05C 0.85
<TS 953 A
90 115 16 VS6
-0.7
<TS 954 A
90 115 16 VS2
-0.75
<TS 955 A
90 135 12 04H 0.9
<TS 956 A
90 135 15 04C 0.78
<TS 957 A
90 143 23 02C
-0.92
<TS 958 A
90 143 17 02C 0.04
<TS 959 A
91 22 35 VS4 0.45
<TS 960 A
91 22 10 VS6
-0.75
<TS 961 A
91 26 9
03H 0.97
<TS 962 A
91 36 12 06H
-0.72
<TS 963 A
91 66 16 05C 0.87
<TS 964 A
91 70 8
06H 0
<TS 965 A
91 70 15 VS6 0.92
<TS 966 A
91 80 14 05C 1.12
<TS 967 A
91 80 10 07C 0.95
<TS 968 A
91 90 20 03C 0.76
<TS 969 A
91 90 10 05H 0.97
<TS 970 A
91 92 13 05H 0.97
<TS 971 A
91 94 13 05H 0.19
<TS 972 A
91 114 15 VS2
-0.8
<TS 973 A
91 116 27 VS2
-0.72
<TS 974 A
91 144 15 VS4 0.68
<TS 975 A
91 144 8
03C
-0.92
<TS 976 A
92 23 22 VS2 0.49
<TS 977 A
92 23 18 VS2 0.84
<TS 978 A
92 23 8
VS6 0.56
<TS 979 A
92 23 27 VS6 0.88
<TS 980 A
92 25 11 VS4
-0.8
<TS 981 A
92 25 14 VS4 0.97
<TS 982 A
92 29 17 03H 0.86
<TS 983 A
92 33 12 04H 0.92
<TS 984 A
92 35 16 06H 0.98
<TS Page C-19 L___
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 985 A
92 37 12 04H 0.89
<TS 986 A
92 51 11 05C 0.02
<TS 987 A
92 59 13 VS4
-0.84
<TS 988 A
92 59 10 VS4 0.17
<TS 989 A
92 59 16 VS4 0.88
<TS 990 A
92 59 13 VS6 1.1
<TS 991 A
92 69 10 05C 0.81
<TS 992 A
92 69 13 05C 0.02
<TS 993 A
92 77 12 05C
-0.95
<TS 994 A
92 77 10 06C
-1
<TS 995 A
92 81 10 05H 0.89
<TS 996 A
92 81 12 06H
-0.78
<TS 997 A
92 85 17 VS6 0.99
<TS 998 A
92 89 16 06H 0.91
<TS 999 A
92 89 16 05C 0.88
<TS 1000 A
92 89 19 04C 0.72
<TS 1001 A
92 101 17 VS2
-0.77
<TS 1002 A
92 101 18 VS2 0.75
<TS 1003 A
92 117 13 VS4
-0.56
<TS 1004 A
92 117 13 VS4 0.95
<TS 1005 A
92 125 14 03H 0.45
<TS 1006 A
92 133 17 07H 0.92
<TS 1007 A
92 133 16 05C
-0.92
<TS 1008 A
92 133 18 04C 0.77
<TS 1009 A
92 135 18 04C 0.64
<TS 1010 A
92 137 10 04C 0.79
<TS 1011 A
92 141 12 04C 0.85
<TS 1012 A
92 141 14 02C
-0.2
<TS 1013 A
93 26 11 VS4
-0.76
<TS 1014 A
93 26 11 VS4 1.02
<TS 1015 A
93 26 10 DBC 1.13
<TS 1016 A
93 52 13 04C 0.75
<TS 1017 A
93 60 22 VS2
-0.65
<TS 1018 A
93 60 22 VS2 1.14
<TS 1019 A
93 60 14 VS6
-0.84
<TS 1020 A
93 60 14 VS6 0.99
<TS 1021 A
93 70 13 02H
-0.8
<TS 1022 A
93 70 10 04H 1.03
<TS I 1023 A
93 76 16 VS4 0.82
<TS 1024 A
93 76 16 VS4 0.23
<TS 1025 A
93 82 13 VS2 1.03
<TS 1026 A
93 84 11 03H
-0.84
<TS 1027 A
93 84 12 04H
-0.82
<TS 1028 A
93 88 11 03H 0.06
<TS 1029 A
93 94 12 04C 0.81
<TS 1030 A
93 100 11 VS2
-0.75
<TS 1031 A
93 104 13 DBH 1.78
<TS 1032 A
93 104 34 VS4
-0.6
<TS 1033 A
93 104 15 VS6
-0.97
<TS 1034 A
93 104 28 VS6 0.94
<TS 1035 A
93 106 21 VS2
-0.63
<TS 1036 A
93 116 10 DBH 1.78
<TS Page C-20
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1037 A
93 130 15 03H
-0.7
<TS 1038 A
93 130 17 VS2 1.08
<TS 1039 A
93 130 20 VS4
-0.73
<TS 1040 A
93 130 39 VS4 1.03
<TS 1041 A
93 130 10 04H
-0.81
<TS 1042 A
93 130 23 VS2
-0.67
<TS 1043 A
93 136 13 03C 0.83
<TS 1044 A
93 136 17 03C
-1.1
<TS 1045 A
93 138 15 05C 0.83
<TS 1046 A
94 25 9
03H
-0.85
<TS 1047 A
94 25 12 VS4
-0.87
<TS 1048 A
94 25 8
VS4
-0.09
<TS 1049 A
94 27 11 03H 0.9
<TS 1050 A
94 31 19 VS4
-0.83
<TS 1051 A
94 51 15 04C 0.75
<TS 1052 A
94 57 11 VS6
-0.83
<TS 1053 A
94 57 12 05C 0.78
<TS 1054 A
94 61 14 04H 0.92
<TS 1055 A
94 67 19 VS6
-0.92
<TS 1056 A
94 67 13 VS6 0.71
<TS 1057 A
94 69 14 05H
-0.82
<TS 1058 A
94 77 27 VS2 1.07
<TS 1059 A
94 77 13 VS2
-0.73
<TS 1060 A
94 77 9
VS6
-0.86
<TS 1061 A
94 85 14 02C 0.76
<TS 1062 A
94 93 16 06C 0.8
<TS 1063 A
94 95 17 07C
-0.92
<TS 1064 A
94 101 21 04C
-1.06
<TS 1065 A
94 107 9
03H
-0.72
<TS 1066 A
95 24 28 VS4
-1.19
<TS 1067 A
95 24 20 VS4 0.11
<TS 1068 A
95 26 12 VS4 0.93
<TS 1069 A
95 30 13 VS6 0.02
<TS 1070 A
95 30 29 VS4 0.9
<TS 1071 A
95 30 35 VS4
-0.79
<TS 1072 A
95 32 7
04H
-0.13
<TS 1073 A
95 48 18 06C 0.86
<TS 1074 A
95 58 11 04H 0.96.
<TS 1075 A
95 58 10 VS2
-0.69
<TS 1076 A
95 60 12 06H 0.9
<TS 1077 A
95 84 18 05C 0.85
<TS 1078 A
95 94 13 DBC 1.67
<TS 1079 A
95 110 10 04H 0.84
<TS 1080 A
95 118 11 VS2 0.3
<TS 1081 A
95 124 18 VS2
-0.73
<TS 1082 A
95 124 21 VS2 0.88
<TS 1083 A
95 126 15 VS2 1
<TS 1084 A
95 130 12 VS2 0.06
<TS 1085 A
95 130 19 VS2 1.11
<TS 1086 A
95 132 18 VS2 1.03
<TS 1087 A
95 132 11 VS4 1.03
<TS 1088 A
95 134 26 04C
-0.99
<TS Page C-21
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1089 A
95 136 24 VS2 1.02
<TS 1090 A
95 136 16 VS2
-0.78
<TS 1091 A
95 140 20 04C 0.64
<TS 1092 A
95 142 12 02C 0.77
<TS 1093 A
95 142 15 02C
-0.07
<TS 1094 A
96 25 17 02H 0.84
<TS 1095 A
96 25 37 VS4 0.78
<TS 1096 A
96 27 12 VS4 1.12
<TS 1097 A
96 31 11 VS4 0.88
<TS 1098 A
96 31 13 VS6
-0.62
<TS 1099 A
96 33 10 06H
-0.95
<TS 1100 A
96 33 11 VS4
-0.86
<TS 1101 A
96 37 15 VS6
-0.74
<TS 1102 A
96 39 10 VS6 0.31
<TS 1103 A
96 41 14 04C 0.77
<TS 1104 A
96 41 14 VS6
-0.17
<TS 1105 A
96 41 18 VS6 1.08
<TS 1106 A
96 55 12 06C
-0.95
<TS 1107 A
96 59 15 07C
-0.88
<TS 1108 A
96 59 19 04C
-0.94
<TS 1109 A
96 61 11 04H 0.21
<TS 1110 A
96 61 12 06H 0.87
<TS 1111 A
96 61 17 06C 0.02
<TS 1112 A
96 63 21 04C 0.74
<TS 1113 A
96 65 11 05H
-0.89
<TS 1114 A
96 73 7
05H 0.96
<TS 1115 A
96 87 15 05H 0.94
<TS 1116 A
96 87 18 05C 0.79
<TS 1117 A
96 91 12 04H
-0.02
<TS 1118 A
96 99 11 04H
-0.08
<TS 1119 A
96 103 14 05C 0.79
<TS 1120 A
96 105 15 07H 0.9
<TS 1121 A
96 105 20 VS6
-0.62
<TS 1122 A
96 109 17 04C 0.86
<TS 1123 A
96 111 19 05C 0.77
<TS 1124 A
96 117 18 VS6
-0.63
<TS 1125 A
96 121 19 VS6 1.15
<TS 1126 A
96 131 21 04C
-1.09
<TS 1127 A
96 141 15 VS4
-0.94
<TS 1128 A
96 141 12 VS4 0.85
<TS 1129 A
97 26 14 VS4
-0.84
<TS 1130 A
97 26 16 VS4 0.5
<TS 1131 A
97 28 8
VS4
-0.49
<TS 1132 A
97 28 15
. VS4 1.01
<TS 1133 A
97 46 9
VS4 0.95
<TS 1134 A
97 46 14 VS6
-0.71
<TS 1135 A
97 46 13 VS6
-0.13
<TS 1136 A
97 48 9
DBC 1.83
<TS 1137 A
97 48 17 VS6 0.97
<TS 1138 A
97 48 16 VS6
-0.84
<TS 1139 A
97 48 18 VS4 0.99
<TS 1140 A
97 48 15 VS4
-0.82
<TS Page C-22
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1141 A
97 50 20 VS6 0.74
<TS 1142 A
97 50 17 VS4 0.96
<TS 1143 A
97 50 18 VS4
-0.74
<TS 1144 A
97 50 14 VS2 0.87
<TS 1145 A
97 50 29 VS2
-0.87
<TS 1146 A
97 52 25 VS6 0.77
<TS 1147 A
97 52 28 VS4
-0.61
<TS 1148 A
97 52 20 VS2 0.83
<TS 1149 A
97 52 8
VS2
-0.86
<TS 1150 A
97 54 14 05C
-0.2
<TS 1151 A
97 58 17 07C 0.89
<TS 1152 A
97 62 19 06C 0.82
<TS 1153 A
97 64 11 05H 0.99
<TS 1154 A
97 64 17 06C
-0.89
<TS 1155 A
97 80 9
01C 0.81
<TS 1156 A
97 82 16 05C 0.79
<TS 1157 A
97 90 7
VS2
-0.09
<TS 1158 A
97 90 15 VS2 0.86
<TS 1159 A
97 90 16 VS4 0.97
<TS 1160 A
97 90 26 VS6
-0.73
<TS 1161 A
97 90 10 VS4
-0.75
<TS 1162 A
97 90 15 05C 0.76
<TS 1163 A
97 96 13 VS2 0.71
<TS 1164 A
97 96 16 VS2 0.19
<TS 1165 A
97 96 15 04C
-0.89
<TS 1166 A
97 100 12 VS2 0.19
<TS 1167 A
97 106 16 VS4 0.91
<TS 1168 A
97 106 26 VS4
-0.83
<TS 1169 A
97 112 15 VS4
-0.89
<TS 1170 A
97 114 14 VS4
-0.89
<TS 1171 A
97 116 20 05C 0.77
<TS 1172 A
97 116 19 VS4
-0.93
<TS 1173 A
97 118 23 VS4 0.64
<TS 1174 A
97 120 13 VS2
-0.8
<TS 1175 A
97 120 25 VS2 1.01
<TS 1176 A
97 120 12 VS4 0.69
<TS 1177 A
97 124 9
VS2
-0.81
<TS 1178 A
97 124 10 VS2 0.96
<TS 1179 A
97 126 15 VS4
-0.04
<TS 1180 A
97 132 12 DBH 1.97
<TS 1181 A
97 132 13 VS4 0.92
<TS 1182 A
97 132 14 04C
-1.01
<TS 1183 A
97 134 20 VS4 0.95
<TS 1184 A
97 136 13 04C
-0.98
<TS 1185 A
97 138 16 02C 0.85
<TS 1186 A
98 27 15 VS6 0.87
<TS 1187 A
98 27 9
VS6
-0.83
<TS 1188 A
98 27 17 VS2 0.63
<TS 1189 A
98 35 11 05H 0.86
<TS 1190 A
98 39 16 05H 0.93
<TS 1191 A
98 51 14 05C 0.84
<TS 1192 A
98 55 10 DBC
-1.68
<TS Page C-23
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1193 A
98 55 12 05H 0.93
<TS 1194 A
98 59 14 05C
-0.99
<TS 1195 A
98 63 17 05C
-0.96
<TS 1196 A
98 65 21 VS2
-0.6
<TS 1197 A
98 75 19 06C 0.81
<TS 1198 A
98 85 17 06C 0.74
<TS 1199 A
98 85 10 DBC 1.68
<TS 1200 A
98 85 12 VS6
-0.72
<TS 1201 A
98 87 21 06C 0.78
<TS 1202 A
98 87 10 06C
-1
<TS 1203 A
98 105 24 04C 0.76
<TS 1204 A
98 105 20 05C
-1
<TS 1205 A
98 109 12 05H
-0.91
<TS 1206 A
98 109 17 05C 0.81
<TS 1207 A
98 111 15 VS2 0.57
<TS 1208 A
98 111 9
VS2
-0.19
<TS 1209 A
98 111 14 07H 0.21
<TS 1210 A
98 113 12 VS2 0.6
<TS 1211 A
98 119 14 VS6 0.84
<TS 1212 A
98 127 19 07H 0.86
<TS 1213 A
99 26 20 VS4
-0.71
<TS 1214 A
99 26 20 VS4
-0.39
<TS 1215 A
99 28 12 VS4 0.95
<TS 1216 A
99 28 10 VS4
-0.37
<TS 1217 A
99 30 12 VS4
-0.88
<TS 1218 A
99 30 7
VS4 0.57
<TS 1219 A
99 36 15 VS4 0.84
<TS 1220 A
99 70 9
06H
-0.05
<TS 1221 A
99 84 17 VS6
-0.92
<TS 1222 A
99 94 14 03C 0.87
<TS 1223 A
99 96 10 07C 0.04
<TS 1224 A
99 104 15 02C
-0.98
<TS 1225 A
99 104 12 02C
-0.04
<TS 1226 A
99 112 16 04C 0.81
<TS 1227 A
99 116 12 VS4
-0.94
<TS 1228 A
99 136 11 VS4
-1.04
<TS 1229 A
99 136 10 VS4 0.52
<TS 1230 A
99 138 17 02C
-1.02
<TS 1231 A
99 138 13 02C 0.07
<TS 1232 A
99 138 15 03C
-0.41
<TS 1233 A
99 138 19 VS4 0
<TS 1234 A
99 138 16 VS4 0.86
<TS 1235 A
99 138 12 03H 0.9
<TS 1236 A
99 140 26 VS4
-0.55
<TS 1237 A
99 140 19 03C
-0.2
<TS 1238 A
99 140 13 03C
-0.96
<TS 1239 A
100 27 28 VS4
-0.8
<TS 1240 A
100 27 14 VS4
-0.09
<TS 1241 A
100 27 16 VS4 1.1
<TS 1242 A
100 29 16 04H 0.87
<TS 1243 A
100 29 16 05H 0.81
<TS 1244 A
100 29 19 06H 0.88
<TS Page C-24
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1245 A
100 29 13 VS2
-0.9
<TS 1246 A
100 29 22 VS2 0.88
<TS 1247 A
100 29 11 VS4 0
<TS 1248 A
100 29 18 VS4 0.88
<TS 1249 A
100 31 12 04H 0.87
<TS 1250 A
100 31 11 06H
-0.85
<TS 1251 A
100 31 14 06H
-0.09
<TS 1252 A
100 31 14 VS2
-0.88
<TS 1253 A
100 33 11 VS2
-0.91
<TS 1254 A
100 35 12 05C 0
<TS 1255 A
100 35 13 03H
-0.74
<TS 1256 A
100 41 12 06C 0.73
<TS 1257 A
100 49 13 05C 0.81
<TS 1258 A
100 51 8
06H 0
<TS 1259 A
100 61 9
03H
-0.83
<TS 1260 A
100 65 10 06H
-0.9
<TS 1261 A
100 67 30 VS6
-0.81
<TS 1262 A
100 87 11 05C 0.83
<TS 1263 A
100 89 16 VS2
-0.75
<TS 1264 A
100 89 14 03C 0.81
<TS 1265 A
100 103 20 02C 0.74
<TS 1266 A
100 103 16 05C
-0.94
<TS 1267 A
100 107 17 VS4
-0.77
<TS 1268 A
100 113 15 DBH 1.91
<TS 1269 A
100 115 15 05H
-0.85
<TS 1270 A
100 119 22 VS2
-0.69
<TS 1271 A
100 119 24 VS2 0.13
<TS 1272 A
100 119 10 VS2 0.86
<TS 1273 A
100 119 12 VS4
-0.64
<TS 1274 A
100 119 12 VS6 0.99
<TS 1275 A
100 131 12 05C 0.71
<TS 1276 A
100 137 16 05C
-0.86
<TS 1277 A
100 137 9
VS4 0.97
<TS 1278 A
100 137 11 VS4
-0.82
<TS 1279 A
100 137 33 03C
-0.6
<TS 1280 A
100 139 20 VS4
-0.83
<TS 1281 A
100 139 17 03C
-0.17
<TS 1282 A
101 28 13 03H 0.82
<TS 1283 A
101 28 19 VS4
-0.88
<TS 1284 A
101 28 23 VS4 0.67
<TS 1285 A
101 30 18 04H
-0.11
<TS 1286 A
101 30 17 VS4
-0.93
<TS 1287 A
101 30 13 VS4 0.71
<TS 1288 A
101 36 7
03H 0.9
<TS 1289 A
101 40 9
05H 0.13
<TS 1290 A
101 44 13 VS2 0.76
<TS 1291 A
101 48 12 DBC 1.79
<TS 1292 A
101 56 15 06C
-0.95
<TS 1293 A
101 68 10 06H 0.96
<TS 1294 A
101 70 14 05H 0.96
<TS 1295 A
101 70 11 07C
-0.61
<TS 1296 A
101 78 6
07H
-0.77
<TS Page C-25
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1297 A
1D1 78 s
D7H D.2S
<TS 1298 A
1D1 86 11 D7C D.7S
<TS 1299 A
1D1 106 16 D4C D.84
<TS 13DD A
1D1 110 12 VS2 D.74
<TS 13D1 A
1D1 110 12 VS2 D.1S
<TS 13D2 A
1D1 118 1S DBH 1.89
<TS 13D3 A
1D1 124 12 D7C D.7S
<TS 13D4 A
1D1 128 12 D4H
-D.83
<TS 13DS A
1D1 136 11 D3C
-1.D6
<TS 13D6 A
1D1 136 14 D2C D
<TS 13D7 A
1D1 138 2D VS4 D.8S
<TS 13D8 A
1D1 138 11 D7C D.79
<TS 13D9 A
1D2 29 26 VS4
-D.82
<TS 131D A
1D2 29 16 D4C
-1.D1
<TS 1311 A
1D2 29 1D VS4
-D.D9
<TS 1312 A
1D2 31 9
D2C D.7S
<TS 1313 A
1D2 31 9
D7C D.87
<TS 1314 A
1D2 31 9
D3H D.94
<TS 131S A
1D2 67 1S D7H D.9
<TS 1316 A
1D2 73 16 D7C
-D.92
<TS 1317 A
1D2 7S 13 VS2
-D.66
<TS 1318 A
1D2 89 16 D4C D.76
<TS 1319 A
1D2 91 12 D4C
-D.94
<TS 132D A
1D2 9S 13 DSC
-D.2
<TS 1321 A
1D2 10S 1D D2C D.D2
<TS 1322 A
1D2 1DS 12 D3C
-1
<TS 1323 A
1D2 1DS 8
D3C
-D.D2
<TS 1324 A
1D2 10S 17 DSC D.76
<TS 132S A
1D2 107 13 VS2 D.72
<TS 1326 A
1D2 113 13 DSC D.74
<TS 1327 A
1D2 11S 2D VS2
-D.D6
<TS 1328 A
1D2 11S 1S VS2
-D.68
<TS 1329 A
1D2 117 22 D3H D.98
<TS 133D A
1D2 121 22 VS4
-D.81
<TS 1331 A
1D2 13S 16 D4C D.8
<TS 1332 A
102 13S 1S D3C
-D.1S
<TS 1333 A
1D2 137 14 D4C
-D.96
<TS 1334 A
103 3D 16 VS4 D.S3
<TS 133S A
103 3D 14 DSH
-D.84
<TS 1336 A
1D3 3D 12 D7H
-D.86
<TS 1337 A
103 3D 8
VS4
-D.13
<TS 1338 A
103 32 18 VS4
-1.D2
<TS 1339 A
103 32 10 VS4 D.S
<TS 134D A
103 32 11 D3C D.2
<TS 1341 A
103 32 13 D2C
-D.22
<TS 1342 A
1D3 36 9
VS2
-D.89
<TS 1343 A
103 36 14 VS2 D.89
<TS 1344 A
103 36 13 DSC
-D.93
<TS 134S A
103 S4 11 DSH D.89
<TS 1346 A
103 82 1D DSH
-D.84
<TS 1347 A
103 82 17 DSH D
<TS 1348 A
1D3 82 13 D6H 1.D7
<TS Page C-26
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1349 A
103 86 16 VS2 0.67
<TS 1350 A
103 86 13 VS2 0.17
<TS 1351 A
103 92 12 05C 0.76
<TS 1352 A
103 96 13 05C 0.81
<TS 1353 A
103 108 13 07C
-0.22
<TS 1354 A
103 122 18 DBC 1.46
<TS 1355 A
103 134 14 04C 0.09
<TS 1356 A
103 134 13 04C 0.83
<TS 1357 A
103 136 13 DBH
-1.66
<TS 1358 A
104 31 21 VS4
-0.88
<TS 1359 A
104 31 20 VS4 0.82
<TS 1360 A
104 33 12 04C
-0.88
<TS 1361 A
104 33 12 03C
-0.95
<TS 1362 A
104 61 12 06C 0.81
<TS 1363 A
104 69 8
07H
-0.8
<TS 1364 A
104 71 11 DBH 1.83
<TS 1365 A
104 79 10 07H 0.02
<TS 1366 A
104 85 11 VS2
-0.77
<TS 1367 A
104 85 9
04C 0.79
'<TS 1368 A
104 85 21 04C
-0.92
<TS 1369 A
104 87 13 04C
-0.17
<TS 1370 A
104 87 23 04C
-0.96
<TS 1371 A
104 89 15 02C
-0.96
<TS 1372 A
104 95 18 VS2
-0.6
<TS 1373 A
104 97 20 04C
-0.92
<TS 1374 A
104 97 11 03C 0.74
<TS 1375 A
104 97 6
03C 0
<TS 1376 A
104 99 14 06C 0.79
<TS 1377 A
104 103 13 05C 0.83
<TS 1378 A
104 109 17 VS6
-0.52
<TS 1379 A
104 121 12 06C 0.78
<TS 1380 A
104 123 16 04C 0.89
<TS 1381 A
104 135 27 03C 0.72
<TS 1382 A
105 30 25 VS4
-0.56
<TS 1383 A
105 32 14 01C 0.02
<TS 1384 A
105 32 12 04H
-0.9
<TS 1385 A
105 90 18 05C 0.77
<TS 1386 A
105 92 14 07C
-0.9
<TS 1387 A
105 122 10 06C 0.72
<TS 1388 A
105 132 21 03C 0.77
<TS 1389 A
105 136 15 VS4
-0.72
<TS 1390 A
105 136 15 VS4 1.09
<TS 1391 A
106 31 9
VS2 0.19
<TS 1392 A
106 31 16 VS4 0.99
<TS 1393 A
106 31 34 VS6
-0.89
<TS 1394 A
106 31 19 VS6 0.22
<TS 1395 A
106 31 32 VS6 0.76
<TS 1396 A
106 31 21 04C 0.71
<TS 1397 A
106 31 12 03C 0.74
<TS 1398 A
106 31 15 01C
-0.97
<TS 1399 A
106 33 17 VS4
-0.61
<TS 1400 A
106 33 11 VS4
-0.92
<TS Page C-27
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1401 A
106 33 11 04C
-0.92
<TS 1402 A
106 35 16 03C
-0.09
<TS 1403 A
106 35 18 03C 0.68
<TS 1404 A
106 45 11 05H
-0.13
<TS 1405 A
106 47 14 04C 0.02
<TS 1406 A
106 47 14 04C 0.73
<TS 1407 A
106 47 11 DBC 1.62
<TS 1408 A
106 57 19 07H 1.05
<TS 1409 A
106 59 6
DBH 1.89
<TS 1410 A
106 59 14 VS2
-0.87
<TS 1411 A
106 59 22 VS4
-1.11
<TS 1412 A
106 59 35 VS4 0.96
<TS 1413 A
106 59 22 VS6
-0.69
<TS 1414 A
106 63 12 VS4
-0.94
<TS 1415 A
106 63 15 VS4 0.34
<TS 1416 A
106 67 19 VS6 0.39
<TS 1417 A
106 67 10 VS4
-0.51
<TS 1418 A
106 69 15 VS2 0.62
<TS 1419 A
106 69 14 VS4
-1.1
<TS 1420 A
106 69 12 VS6 0.92
<TS 1421 A
106 69 13 07C
-0.23
<TS 1422 A
106 101 14 04H 0.86
<TS 1423 A
106 117 14 VS2
-0.15
<TS 1424 A
106 117 17 06C
-1.04
<TS 1425 A
106 119 11 VS4 1.14
<TS 1426 A
106 121 9
04C
-0.02
<TS 1427 A
106 121 17 05C 0.48
<TS 1428 A
106 121 17 04C 0.73
<TS 1429 A
106 131 11 03C
-0.82
<TS 1430 A
106 133 19 DBC 1.44
<TS 1431 A
106 135 10 01H 0.13
<TS 1432 A
106 135 26 VS4
-0.59
<TS 1433 A
107 32 35 VS4
-0.65
<TS 1434 A
107 32 12 VS4
-0.15
<TS 1435 A
107 32 16 04C
-0.24
<TS 1436 A
107 32 9
04C
-0.85
<TS 1437 A
107 32 13 03C 0.83
<TS 1438 A
107 34 10 VS4 0.96
<TS 1439 A
107 34 9
01H 0.95
<TS 1440 A
107 36 10 03C 0.81
<TS 1441 A
107 40 9
VS2
-0.87
<TS 1442 A
107 44 12 05H
-0.93
<TS 1443 A
107 44 15 05H
-0.15
<TS 1444 A
107 44 9
VS4 0.89
<TS 1445 A
107 44 12 VS2 0.68
<TS 1446 A
107 92 11 05C 0.76
<TS 1447 A
107 120 13 DBH 1.98
<TS 1448 A
107 122 11 03C
-0.19
<TS 1449 A
107 124 12 VS2
-0.97
<TS 1450 A
107 124 17 VS2
-0.15
<TS 1451 A
107 124 11 VS2 0.6
<TS 1452 A
107 124 13 03C
-0.96
<TS I
Page C-28
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1453 A
107 128 13 04C
-1.13
<TS 1454 A
107 130 20 VS2
-0.92
<TS 1455 A
107 130 9
VS2 0.62
<TS 1456 A
107 134 14 03H 0.91
<TS 1457 A
107 134 24 VS4
-0.94
<TS 1458 A
107 134 17 VS4 0.87
<TS 1459 A
107 134 26 02C
-1
<TS 1460 A
108 33 12 01H 0.89
<TS 1461 A
108 33 33 VS4
-0.82
<TS 1462 A
108 33 27 VS4 0.95
<TS 1463 A
108 35 14 VS4
-0.87
<TS 1464 A
108 35 11 VS4 1
<TS 1465 A
108 35 20 01C 0.79
<TS 1466 A
108 35 29 01C 0
<TS 1467 A
108 39 9
04H 0.88
<TS 1468 A
108 41 18 VS4 0.95
<TS 1469 A
108 63 10 VS2 0.21
<TS 1470 A
108 63 17 VS2 0.81
<TS 1471 A
108 65 14 DBH 1.77
<TS 1472 A
108 69 13 07C 0.76
<TS 1473 A
108 87 14 05C 0.74
<TS 1474 A
108 89 14 06C
-0.99
<TS 1475 A
108 93 17 06C 0.35
<TS 1476 A
108 95 14 03C 0.85
<TS 1477 A
108 99 9
DBH 1.9
<TS 1478 A
108 115 16 05H 0.97
<TS 1479 A
108 117 13 05C 0.85
<TS 1480 A
108 123 18 VS2
-0.69
<TS 1481 A
108 133 12 04C 0.7
<TS 1482 A
108 133 17 04C
-0.96
<TS 1483 A
109 34 14 01H 0.94
<TS 1484 A
109 34 12 04H
-0.84
<TS 1485 A
109 34 15 05H
-0.76
<TS 1486 A
109 34 12 VS4
-0.87
<TS 1487 A
109 34 34 VS4 0.63
<TS 1488 A
109 34 12 01C 0.83
<TS 1489 A
109 90 12 07C
-0.09
<TS 1490 A
109 90 9
07C
-0.9
<TS 1491 A
109 98 27 VS2
-0.8
<TS 1492 A
109 118 17 04C
-1
<TS 1493 A
109 120 18 03C
-0.17
<TS 1494 A
109 132 21 04C 0.66
<TS 1495 A
110 35 16 01H 0.91
<TS 1496 A
110 35 14 VS4 0.92
<TS 1497 A
110 39 20 VS2 0.87
<TS 1498 A
110 91 14 04C
-0.9
<TS 1499 A
110 123 23 08H
-0.92
<TS 1500 A
110 131 17 01H 0.21
<TS 1501 A
110 131 32 DBH
-1.8
<TS 1502 A
110 131 17 03C 0.79
<TS 1503 A
111 44 16 06C
-0.18
<TS 1504 A
111 62 18 VS2
-0.74
<TS Page C-29
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1505 A
111 110 15 VS4
-0.94
<TS 1506 A
111 116 20 03H 0.92
<TS 1507 A
111 126 15 04C 0.78
<TS 1508 A
111 128 11 VS4 1.02
<TS 1509 A
111 128 12 03C 0.87
<TS 1510 A
111 128 21 03C
-0.9
<TS 1511 A
111 130 21 04C
-0.19
<TS 1512 A
112 37 22 02C
-0.99
<TS 1513 A
112 37 13 DBH
-1.63
<TS 1514 A
112 39 7
VS6 0.97
<TS 1515 A
112 41 11 VS6
-0.79
<TS 1516 A
112 41 19 VS4
-0.92
<TS 1517 A
112 59 20 VS4
-0.84
<TS 1518 A
112 59 23 VS4 0.06
<TS 1519 A
112 59 33 VS6 1.03
<TS 1520 A
112 65 13 VS4
-0.78
<TS 1521 A
112 65 12 VS4 0.73
<TS 1522 A
112 89 14 VS4
-0.81
<TS 1523 A
112 89 11 04C
-0.9
<TS 1524 A
112 103 14 04H 0.88
<TS 1525 A
112 125 11 05C
-0.89
<TS 1526 A
112 125 12 04C 0.85
<TS 1527 A
112 127 18 05C
-1.07
<TS 1528 A
112 129 14 04C 0.77
<TS 1529 A
113 36 16 01H 0.93
<TS 1530 A
113 36 19 VS4
-0.54
<TS 1531 A
113 36 12 01H
-0.1
<TS 1532 A
113 38 9
01C
-1.07
<TS 1533 A
113 38 10 02C 0.79
<TS 1534 A
113 42 13 VS4
-0.84
<TS 1535 A
113 42 13 VS4 1.06
<TS 1536 A
113 68 18 VS2
-0.66
<TS 1537 A
113 68 12 VS4
-0.8
<TS 1538 A
113 68 15 VS6 1.03
<TS 1539 A
113 76 16 VS6 0.87
<TS 1540 A
113 90 12 VS4
-0.54
<TS 1541 A
113.
90 14 03C
-0.94
<TS 1542 A
113 118 16 04C 0
<TS 1543 A
113 128 18 04H
-0.82
<TS 1544 A
113 128 14 03H 0.97
<TS 1545 A
113 130 21 VS4
-0.64
<TS 1546 A
113 130 23 VS4
-0.26
<TS 1547 A
114 47 10 05H 0.97
<TS 1548 A
114 119 12 03C 0.73
<TS 1549 A
114 123 18 03C
-1.1
<TS 1550 A
114 129 14 08H
-0.9
<TS 1551 A
114 129 24 VS4
-0.86
<TS 1552 A
114 129 12 VS4 1.06
<TS 1553 A
115 38 14 VS4 0.49
<TS 1554 A
115 38 14 VS4 0.83
<TS 1555 A
115 38 16 02C
-0.04
<TS 1556 A
115 38 17 02C
-1.01
<TS Page C-30
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1SS7 A
11S 46 14 VS4
-0.87
<TS 1SS8 A
11S so 10 VS4
-0.6S
<TS 1SS9 A
11S 78 16 06H
-0.?S
<TS 1S60 A
11S 90 11 VS2
-1.07
<TS 1S61 A
11S 9D 38 VS4
-0.77
<TS 1S62 A
11S 92 2S VS1 D.97
<TS 1S63 A
11S 124 12 DSC D.79
<TS 1S64 A
11S 124 17 D4C
-1.D2
<TS 1S6S A
11S 124 13 D3C D.74
<TS 1S66 A
11S 128 1D DSH D.86
<TS 1S67 A
116 39 1S VS6
-D.6S
<TS 1S68 A
116 39 34 D2C
-D.9
<TS 1S69 A
116 39 13 D1C
-D.18
<TS 1S7D A
116 4S 1S D2H D.87
<TS 1S71 A
116 4S 14 VS?
D.86
<TS 1S72 A
116 S1 17 D7H D.82
<TS 1S73 A
116 S1 12 DSH
-D.13
<TS 1S74 A
116 SS 12 DSH
-D.66
<TS 1S7S A
116 61 8
VS4 D.93
<TS 1S76 A
116 63 12 VS6
-D.83
<TS 1S77 A
116 71 9
VS4 D.82
<TS 1S78 A
116 81 11 VS6
-D.8
<TS 1S79 A
116 9S 16 D7C
-D.99
<TS 1S8D A
116 9S 11 D6C D.7
<TS 1S81 A
116 10S 2S VS4
-D.97
<TS 1S82 A
116 111 1S DSC
-D.1S
<TS 1S83 A
116 119 19 D3C D.94
<TS 1S84 A
116 121 13 VS?
D.9
<TS 1S8S A
116 121 2S D4C D.78
<TS 1S86 A
116 123 19 D6C O.S
<TS 1S87 A
117 4D 23 VS4
-D.67
<TS 1S88 A
117 4D 26 D2C D.79
<TS 1S89 A
117 4D 10 D2C
-D.28
<TS 1S9D A
117 42 10 D2C D.81
<TS 1S91 A
117 42 33 D1C
-1.D4
<TS 1S92 A
117 SD 11 VS4
-D.6S
<TS 1S93 A
117 S8 12 D6C D.82
<TS 1S94 A
117 7D 13 D6C D.79
<TS 1S9S A
117 9D 11 VS2 D.82
<TS 1S96 A
117 12D 11 D3H D.82
<TS 1S97 A
117 122 13 VS4 D.13
<TS 1S98 A
118 41 29 D2C D
<TS 1S99 A
118 41 2D VS4
-D.8
<TS 16DD A
118 41 12 D1H 1.DS
<TS 16D1 A
118 43 32 D1C
-D.96
<TS 16D2 A
118 43 9
D3H D.94
<TS 16D3 A
118 43 11 D6H
-D.92
<TS 16D4 A
118 47 14 D2H D.81
<TS 16DS A
118 S1 14 D6C D.78
<TS 16D6 A
118 S3 9
VS6
-D.78
<TS 16D7 A
118 63 19 VS4
-D.94
<TS 16D8 A
118 63 14 VS4 D.92
<TS Page C-31
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1609 A
118 97 12 VS2
-0.94
<TS 1610 A
118 99 18 VS2 0.84
<TS 1611 A
118 101 11 04H
-0.13
<TS 1612 A
118 101 12 VS4 0.94
<TS 1613 A
118 105 18 04C 0.87
<TS 1614 A
118 125 20 VS?
-0.91
<TS 1615 A
119 42 14 VS4
-0.89
<TS 1616 A
119 44 10 02H 0.75
<TS 1617 A
119 52 25 06C 0.82
<TS 1618 A
119 60 14 VS4
-0.78
<TS 1619 A
119 60 13 VS4 1.11
<TS 1620 A
119 76 11 06C 0.79
<TS 1621 A
119 82 11 VS4 0.32
<TS 1622 A
119 110 17 04C
-0.93
<TS 1623 A
119 122 12 06H 0.81
<TS 1624 A
119 122 12 03C 0.63
<TS 1625 A
119 124 13 VS4
-0.8
<TS 1626 A
120 45 11 02H 0.87
<TS 1627 A
120 81 9
VS4 0.91
<TS 1628 A
120 89 17 06C
-0.94
<TS 1629 A
120 93 16 06C 0.85
<TS 1630 A
120 111 10 03C
-0.97
<TS 1631 A
120 111 13 04C
-0.02
<TS 1632 A
120 115 17 05C
-1.01
<TS 1633 A
120 119 21 03C 0.84
<TS 1634 A
120 121 22 05C 0.79
<TS 1635 A
120 123 16 01H
-0.08
<TS 1636 A
121 44 22 VS4 0
<TS 1637 A
121 44 10 VS4 0.83
<TS 1638 A
121 44 17 01C
-1.04
<TS 1639 A
121 44 11 VS?
0.87
<TS 1640 A
121 64 7
07H 0.85
<TS 1641 A
121 76 10 VS6 0.89
<TS 1642 A
121 104 12 VS4 0.58
<TS 1643 A
121 116 23 03C 0.79
<TS 1644 A
121 118 32 VS4
-0.74
<TS 1645 A
121 118 21 VS4
-0.07
<TS 1646 A
121 118 17 VS4 0.74
<TS 1647 A
121 118 27 03C 0.81
<TS 1648 A
121 120 12 06H 0.9
<TS 1649 A
122 45 13 01C 0.81
<TS 1650 A
122 53 11 06H 0.89
<TS 1651 A
122 63 11 05H 0.16
<TS 1652 A
122 81 20 VS4 0.98
<TS 1653 A
122 113 10 03C 0.74
<TS 1654 A
122 117 13 VS1 0.96
<TS 1655 A
122 117 17 VS2
-0.82
<TS 1656 A
122 117 8
VS2 0.04
<TS 1657 A
123 52 11 06H
-0.87
<TS 1658 A
123 110 12 VS2 0.85
<TS 1659 A
123 110 13 06C
-0.26
<TS 1660 A
123 114 11 04C
-1
<TS Page C-32 l
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1661 A
123 120 13 02H 0.87
<TS 1662 A
123 120 11 VS4
-0.62
<TS 1663 A
124 49 13 01H 0.92
<TS 1664 A
124 51 11 03H 0.96
<TS 1665 A
124 117 15 03C
-0.02
<TS 1666 A
124 119 12 VS4
-0.75
<TS 1667 A
125 48 23 VS4
-0.71
<TS 1668 A
125 110 23 03C 0.76
<TS 1669 A
125 112 16 VS6
-0.7
<TS 1670 A
125 112 20 07H
-0.19
<TS 1671 A
125 112 17 03C 0.04
<TS 1672 A
125 114 10 03H
-0.17
<TS 1673 A
126 51 12 VS2 0.8
<TS 1674 A
126 51 10 01H 0.09
<TS 1675 A
126 51 20 03H 0.92
<TS 1676 A
126 63 10 07H 0.89
<TS 1677 A
126 69 14 VS4
-0.8
<TS 1678 A
126 69 35 VS4 0.89
<TS 1679 A
126 77 10 VS1
-0.89
<TS 1680 A
126 77 14 VS1 0.91
<TS 1681 A
126 103 11 VS1 1.01
<TS 1682 A
126 103 33 VS4
-0.82
<TS 1683 A
126 111 19 VS?
1.05
<TS 1684 A
126 115 21 02C
-0.96
<TS 1685 A
126 115 17 04C 0.81
<TS 1686 A
126 115 14 VS6
-0.74
<TS 1687 A
127 52 8
03C
-0.18
<TS 1688 A
127 56 12 DBH 2.07
<TS 1689 A
127 56 8
VS1 0.76
<TS 1690 A
127 56 10 VS1
-0.8
<TS 1691 A
127 56 12 VS4 1.09
<TS 1692 A
127 56 13 VS6 0.87
<TS 1693 A
127 72 19 VS6
-0.23
<TS 1694 A
127 76 11 VS1
-0.98
<TS 1695 A
127 76 11 VS4 1.07
<TS 1696 A
127 80 13 VS?
0.78
<TS 1697 A
127 80 15 06C 0.84
<TS 1698 A
127 98 13 04C
-1
<TS 1699 A
127 106 15 VS4
-0.54
<TS 1700 A
127 108 17 05C
-1.05
<TS 1701 A
127 110 28 VS2
-0.85
<TS 1702 A
127 110 14 VS2 0.83
<TS 1703 A
127 110 13 VS4
-0.13
<TS 1704 A
127 110 13 VS4
-0.62
<TS 1705 A
127 112 27 03C
-0.93
<TS 1706 A
127 114 19 VS4
-0.11
<TS 1707 A
128 53 20 02H
-0.96
<TS 1708 A
128 55 10 VS1
-0.82
<TS 1709 A
128 55 12 VS6
-0.09
<TS 1710 A
128 55 14 VS?
1.16
<TS 1711 A
128 69 14 08H 0.96
<TS 1712 A
128 71 19 VS1
-0.96
<TS Page C-33
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1713 A
128 71 31 VS1 0.85
<TS 1714 A
128 71 17 VS2 0
<TS 1715 A
128 77 16 07C 0.9
<TS 1716 A
128 85 14 DBH 1.86
<TS 1717 A
128 101 13 VS2
-0.71
<TS 1718 A
128 103 10 VS2 0.88
<TS 1719 A
128 111 15 05C 0.7
<TS 1720 A
129 54 30 02C
-1.03
<TS 1721 A
129 56 20 02H 1.07
<TS 1722 A
129 58 28 02H 0.88
<TS 1723 A
129 58 10 VS2
-0.85
<TS 1724 A
129 74 14 VS1
-0.82
<TS 1725 A
129 84 13 VS4 0.67
<TS 1726 A
129 86 11 DBH 1.78
<TS 1727 A
129 92 13 VS4
-0.82
<TS 1728 A
129 94 12 VS4 0.56
<TS 1729 A
129 94 13 VS4 0.04
<TS 1730 A
129 110 24 02C 0.76
<TS 1731 A
129 110 17 04C
-0.02
<TS 1732 A
129 112 17 VS2
-0.76
<TS 1733 A
130 55 16 02H 0.84
<TS 1734 A
130 57 12 02H 0.93
<TS 1735 A
130 57 21 08H 0.84
<TS 1736 A
130 71 20 VS4
-0.92
<TS 1737 A
130 73 12 VS6 0.98
<TS 1738 A
130 73 16 VS7 0.85
<TS 1739 A
130 89 9
DBC
-1.86
<TS 1740 A
130 93 12 DBH 1.94
<TS 1741 A
130 95 21 VS4
-1.03
<TS 1742 A
130 99 24 03C
-0.2
<TS 1743 A
130 99 9
03C
-0.87
<TS 1744 A
130 107 14 03C
-0.26
<TS 1745 A
130 107 17 02C 0.93
<TS 1746 A
131 70 11 DBC 1.69
<TS 1747 A
131 76 12 06C 0.77
<TS 1748 A
131 94 18 08H 0.95
<TS 1749 A
131 94 14 08H
-0.84
<TS 1750 A
131 94 17 VS1 0.76
<TS 1751 A
131 96 19 06C 0.78
<TS 1752 A
131 106 13 03C
-0.8
<TS 1753 A
132 59 11 01C 0.68
<TS 1754 A
132 63 10 VS6 0.99
<TS 1755 A
132 67 12 VS2 0.85
<TS 1756 A
132 67 18 VS2
-0.89
<TS 1757 A
132 81 13 DBC 1.78
<TS 1758 A
132 87 10 DBH 1.87
<TS 1759 A
132 91 19 DBC
-1.96
<TS 1760 A
132 93 31 VS2 0.59
<TS 1761 A
132 95 34 VS?
0.85
<TS 1762 A
132 97 19 VS?
-0.64
<TS 1763 A
132 97 8
08C
-0.02
<TS 1764 A
132 99 13 DBC 1.7
<TS Page C-34
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1765 A
133 60 12 02H
-0.76
<TS 1766 A
133 60 13 02H 0.96
<TS 1767 A
133 60 13 VS4 0.43
<TS 1768 A
133 64 16 05H
-0.11
<TS 1769 A
133 64 11 VS1 1.01
<TS 1770 A
133 66 13 VS4
-0.71
<TS 1771 A
133 84 14 08H
-0.13
<TS 1772 A
133 86 15 DBC
-1.67
<TS 1773 A
133 88 16 DBC 1.65
<TS 1774 A
133 92 24 VS6 0.89
<TS 1775 A
133 92 17 VS7 0.09
<TS 1776 A
133 94 15 VS2 0.78
<TS 1777 A
133 94 15 VS4
-0.69
<TS 1778 A
133 94 21 VS6
-0.88
<TS 1779 A
133 94 13 VS6 0.93
<TS 1780 A
133 94 11 DBC 1.14
<TS 1781 A
133 94 11 DBC
-1.81
<TS 1782 A
134 65 22 07H
-0.09
<TS 1783 A
134 65 12 08H 0.9
<TS 1784 A
134 65 13 DBH
-1.97
<TS 1785 A
134 65 10 VS1 0.9
<TS 1786 A
134 69 19 VS7 0.3
<TS 1787 A
134 69 28 VS7 0.92
<TS 1788 A
134 69 9
VS6 1.13
<TS 1789 A
134 71 12 VS1
-0.87
<TS 1790 A
134 71 19 VS1
-0.02
<TS 1791 A
134 71 20 VS1 0.87
<TS 1792 A
134 89 10 DBC
-1.71
<TS 1793 A
134 91 35 DBC 1.91
<TS 1794 A
134 91 28 VS7
-0.8
<TS 1795 A
134 91 20 VS6
-0.63
<TS 1796 A
134 91 13 VS6 1.02
<TS 1797 A
134 95 31 VS2 0.02
<TS 1798 A
134 95 28 VS4
-0.93
<TS 1799 A
134 95 16 VS4 0.99
<TS 1800 A
134 95 32 VS6 0.95
<TS 1801 A
134 95 37 VS7 0.75
<TS 1802 A
134 99 16 04C
-0.92
<TS 1803 A
134 103 16 02C
-0.87
<TS 1804 A
134 103 14 DBC
-1.85
<TS 1805 A
135 72 27 VS1
-0.82
<TS 1806 A
135 72 13 VS1 1.01
<TS 1807 A
135 72 13 VS7 0.76
<TS 1808 A
135 76 17 DBC 1.86
<TS 1809 A
135 78 25 08C
-1.12
<TS 1810 A
135 78 39 VS6 0.71
<TS 1811 A
135 78 10 VS4 1.1
<TS 1812 A
135 78 6
VS4 0.3
<TS 1813 A
135 78 15 VS1 0.96
<TS 1814 A
135 82 13 08H 0.98
<TS 1815 A
135 82 11 VS4
-0.78
<TS 1816 A
135 86 17 VS4 1.08
<TS Page C-35
A.
Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1817 A
135 86 16 DBC
-1.81
<TS 1818 A
135 90 21 08C 0.71
<TS 1819 A
135 94 27 DBC
-1.84
<TS 1820 A
135 94 28 VS7
-0.61
<TS 1821 A
135 94 24 VS6 0.93
<TS 1822 A
135 94 16 VS6
-0.71
<TS 1823 A
135 94 13 VS4 0.95
<TS 1824 A
135 100 21 VS6
-0.84
<TS 1825 A
135 100 35 VS7
-0.67
<TS 1826 A
135 100 20 DBC 1.83
<TS 1827.
A 135 100 17 04C
-0.94
<TS 1828 A
135 100 20 02C 0.78
<TS 1829 A
136 69 16 VS7
-0.8
<TS 1830 A
136 69 8
VS7 0.82
<TS 1831 A
136 69 10 DBC 1.44
<TS 1832 A
136 69 13 DBC
-1.67
<TS 1833 A
136 79 8
VS7
-0.85
<TS 1834 A
136 79 10 VS7 0.96
<TS 1835 A
136 79 28 07C
-0.26
<TS 1836 A
136 85 16 08H
-1.03
<TS 1837 A
136 91 9
DBC 1.84
<TS 1838 A
136 91 28 08C 0.71
<TS 1839 A
136 91 22 08C
-0.98
<TS 1840 A
136 91 18 07C
-0.96
<TS 1841 A
136 91 12 05C 0
<TS 1842 A
136 91 12 05C
-1.04
<TS 1843 A
136 91 11 04C
-0.91
<TS 1844 A
136 91 24 06C
-0.85
<TS 1845 A
136 93 13 VS6 0.87
<TS 1846 A
137 74 12 DBH 2.01
<TS 1847 A
137 74 10 VS1
-0.59
<TS 1848 A
137 74 23 VS1 0.14
<TS 1849 A
137 74 20 VS1 0.94
<TS 1850 A
137 76 8
VS2
-0.75
<TS 1851 A
137 76 13 VS2
-0.09
<TS 1852 A
137 76 26 VS4
-0.66
<TS 1853 A
137 76 24 VS4 0
<TS 1854 A
137 76 12 VS6 0.07
<TS 1855 A
137 78 17 VS4
-0.57
<TS 1856 A
137 78 22 VS4 1.08
<TS 1857 A
137 78 13 VS7 0.73
<TS 1858 A
137 80 17 VS6
-0.96
<TS 1859 A
137 80 15 VS7 0.16
<TS 1860 A
137 80 24 VS7 0.78
<TS 1861 A
137 88 15 VS4
-0.5
<TS 1862 A
137 88 12 VS6
-0.67
<TS 1863 A
137 88 16 VS6
-0.04
<TS 1864 A
137 90 16 05H
-0.8
<TS 1865 A
137 90 17 DBC 0.76
<TS 1866 A
137 92 29 05C
-0.07
<TS 1867 A
137 92 21 07C
-0.95
<TS 1868 A
137 92 21 08C
-0.96
<TS Page C-36
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1869 A
137 92 28 08C 0.76
<TS 1870 A
137 92 27 VS6
-0.17
<TS 1871 A
137 92 37 VS6
-0.93
<TS 1872 A
137 92 18 VS6 0.93
<TS 1873 A
138 75 29 DBH 1.97
<TS 1874 A
138 75 14 08C
-0.02
<TS 1875 A
138 75 9
07C 0.72
<TS 1876 A
138 81 8
08H
-0.18
<TS 1877 A
138 81 13 08H 0.89
<TS 1878 A
138 81 29 DBH 2.04
<TS 1879 A
138 81 9
VS1
-0.89
<TS 1880 A
138 81 7
VS1 1.03
<TS 1881 A
138 81 9
VS2
-0.14
<TS 1882 A
138 81 13 VS4
-0.94
<TS 1883 A
138 81 19 VS4 1.05
<TS 1884 A
138 81 33 VS6
-0.87
<TS 1885 A
138 81 27 VS6 0.94
<TS 1886 A
138 81 17 VS7 0.18
<TS 1887 A
138 81 20 VS7 0.83
<TS 1888 A
138 81 17 08C
-1.14
<TS 1889 A
138 83 14 08H
-1.07
<TS 1890 A
138 83 9
08H
-0.09
<TS 1891 A
138 83 27 DBH 2.06
<TS 1892 A
138 83 13 VS1
-0.64
<TS 1893 A
138 85 17 DBC
-1.71
<TS 1894 A
138 85 28 VS7 0.97
<TS 1895 A
138 85 16 VS6 0.84
<TS 1896 A
138 85 15 08H
-0.95
<TS 1897 A
138 89 17 VS1 0.95
<TS Page C-37
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX D: SUPPORT WEAR LISTING - SGB Depth No SG Row Column
(%TW)
Location Elevation Status 1
B 1
28 13 D2C D.8
<TS 2
B 1
36 1S D3C D.78
<TS 3
B 1
124 13 D2C D.79
<TS 4
B 1
1SD 23 D1C
-D.6
<TS s
B 1
1S8 17 D2C D.82
<TS 6
B 1
16D 13 D3C
-D.18
<TS 7
B 1
16D 16 D4H D.8S
<TS 8
B 1
16D 11 D4H
-D.21
<TS 9
B 1
164 19 D2C
-D.97
<TS 1D B
2 11 13 D2C D.84
<TS 11 B
2 141 16 D3H
-D.89
<TS 12 B
2 143 14 D2C D.82
<TS 13 B
2 16S 18 D1C D.8
<TS 14 B
3 2
12 D3H D.74
<TS 1S B
3 6
16 D2C D.88
<TS 16 B
3 6
12 D2C
-1
<TS 17 B
3 36 18 D3C D.72
<TS 18 B
3 42 2D D3C D.74
<TS 19 B
4 16S 1S D2C
-D.98
<TS 2D B
4 16S 13 D2C D.84
<TS 21 B
s 138 14 D2H
-D.9S
<TS 22 B
6 16S 24 D2C
-1.D1
<TS 23 B
7 2
19 DSH 1.17
<TS 24 B
7 14D 1S D4C D.8S
<TS 2S B
8 3
1S D3C
-D.2
<TS 26 B
9 46 18 DBH D.S6
<TS 27 B
9 14D 14 D3C D.8
<TS 28 B
10 133 14 D2C D.86
<TS 29 B
11 2
18 D2H D.9S
<TS 3D B
11 112 12 DBC 1.3S
<TS 31 B
11 164 24 D4C D.73
<TS 32 B
11 164 2S D2C
-D.94
<TS 33 B
12 3
16 D3C
-D.9
<TS 34 B
13 2
14 D4C
-D.36
<TS 3S B
13 4
18 D2H
-D.83
<TS 36 B
13 6
16 D3C D.76
<TS 37 B
13 62 16 DSC
-1
<TS 38 B
13 14D 13 D2H D.8S
<TS 39 B
14 37 12 DBH 2.DS
<TS 4D B
14 S7 19 DBC
-1.1S
<TS 41 B
14 1S9 11 D2H
-D.83
<TS 42 B
1S 13D 2S DSC
-D.9S
<TS 43 B
1S 1S4 19 D4H D.98
<TS 44 B
1S 164 17 D2H D.91
<TS 4S B
16 37 10 DSC
-D.18
<TS 46 B
16 SS 11 DBH
-1.S2
<TS 47 B
17 2
14 D3C D.78
<TS 48 B
17 36 1S D4H
-D.84
<TS Page D-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 49 8
18 5
16 03C
-0.18
<TS 50 8
18 137 15 VS4 1.19
<TS 51 8
19 60 11 03H
-0.79
<TS 52 8
19 164 28 02C 0.74
<TS 53 8
21 4
14 03C 0.8
<TS 54 8
21 8
13 03C
-0.96
<TS 55 8
21 58 17 02C 0.85
<TS 56 8
21 64 13 DBC
-1.68
<TS 57 8
22 11 15 02C 0.79
<TS 58 8
22 133 22 VS4 0.98
<TS 59 8
22 163 20 02C 0.84
<TS 60 8
23 106 11 VS4
-0.86
<TS 61 8
24 7
16 DBH 1.78
<TS 62 8
24 53 16 02C 0.87
<TS 63 8
25 6
12 02C
-0.89
<TS 64 8
25 36 10 04H
-0.78
<TS 65 8
25 40 12 04H
-0.75
<TS 66 8
27 64 16 05H 0
<TS 67 8
27 64 19 DBH
-1.68
<TS 68 8
27 64 11 VS4
-0.11
<TS 69 8
28 39 23 VS4 1.08
<TS 70 8
29 120 19 03H 0.88
<TS 71 8
30 5
9 02H
-0.15
<TS 72 8
30 7
12 03C 0.78
<TS 73 8
30 7
8 03C
-0.07
<TS 74 8
30 9
15 02C 0.77
<TS 75 8
30 45 14 VS4 1.05
<TS 76 8
30 51 11 02H 0.86
<TS 77 8
30 53 13 02C 0.83
<TS 78 8
30 57 14 03C
-0.94
<TS 79 8
31 4
15 03C
-0.93
<TS 80 8
31 4
16 02C
-0.87
<TS 81 8
31 4
10 03C 0.07
<TS 82 8
31 14 15 05H
-0.9
<TS 83 8
31 50 16 03C 0.85
<TS 84 8
32 5
13 04H 0.84
<TS 85 8
32 5
15 02C 0.72
<TS 86 8
32 13 16 03C 0.74
<TS 87 8
32 45 10 02H 0.94
<TS 88 8
32 45 11 03H 0.96
<TS 89 8
32 109 11.
04C 0.65
<TS 90 8
32 151 12 VS4 0.97
<TS 91 8
32 157 17 DBH 1.52
<TS 92 8
33 4
15 01C
-0.9
<TS 93 8
33 12 17 VS4 0.94
<TS 94 8
33 32 13 04H 0.97
<TS 95 8
33 52 12 03C 0.79
<TS 96 8
33 54 11 03C
-0.94
<TS 97 8
33 158 20 02C 0.74
<TS 98 8
33 160 14 02C
-1
<TS 99 8
33 162 16 03C 0.89
<TS 100 8
33 162 16 02C
-1.04
<TS Page D-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 101 B
34 11 12 VS4 1
<TS 102 B
34 11 15 DBC
-1.55
<TS 103 B
34 31 22 VS4 0.24
<TS 104 B
34 43 10 03H 0.96
<TS 105 B
34 47 10 03H
-0.85
<TS 106 B
34 59 11 03H
-0.82
<TS 107 B
34 103 17 04H
-0.94
<TS 108 B
34 113 15 01C 0.77
<TS 109 B
34 117 14 04C 0.74
<TS 110 B
34 133 20 03C 0.77
<TS 111 B
34 161 17 02C 0.74
<TS 112 B
35 4
30 DBC 1.91
<TS 113 B
35 4
14 DBC
-0.26
<TS 114 B
35 4
17 01C
-0.93
<TS 115 B
35 6
13 05C
-0.24
<TS 116 B
35 36 21 VS4 0.77
<TS 117 B
35 36 14 03H 0.9
<TS 118 B
35 42 17 05H 1.02
<TS 119 B
35 46 11 03H
-0.9
<TS 120 B
35 46 12 03H 0.83
<TS 121 B
35 46 13 03C 0.76
<TS 122 B
35 52 19 05C 0.81
<TS 123 B
35 52 21 DBC 1.25
<TS 124 B
35 56 15 03H
-0.77
<TS 125 B
35 64 16 05H 0.99
<TS 126 B
36 5
20 03C 0.7
<TS 127 B
36 5
11 03C
-0.04
<TS 128 B
36 41 14 03H
-0.83
<TS 129 B
36 45 23 VS4
-0.78
<TS 130 B
36 49 12 04H 0.84
<TS 131 B
36 51 14 VS4 0.83
<TS 132 B
36 51 8
VS4
-0.7
<TS 133 B
36 109 14 04C 0.83
<TS 134 B
36 113 15 03C 0.78
<TS 135 B
36 119 12 03C
-0.85
<TS 136 B
36 149 19 VS4
-0.84
<TS 137 B
36 149 14 VS4 0.33
<TS 138 B
36 157 18 02C
-0.89
<TS 139 B
36 161 16 02H 0.98
<TS 140 B
36 161 15 04C
-0.19
<TS 141 B
37 6
15 01H
-0.81
<TS 142 B
37 6
20 03H 0.76
<TS 143 B
37 6
16 02C
-0.17
<TS 144 B
37 6
16 02C
-0.98
<TS 145 B
37 10 22 03C
-0.96
<TS 146 B
37 32 12 03H 0.86
<TS 147 B
37 36 12 03H
-0.9
<TS 148 B
37 48 16 02H
-0.75
<TS 149 B
37 50 13 02H
-0.85
<TS 150 B
37 54 16 02H 0.98
<TS 151 B
37 54 13 04C 0.85
<TS 152 B
37 122 25 VS4
-0.83
. <TS Page D-3
-~~~--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 153 B
37 124 15 VS4
-0.85
<TS 154 B
37 124 22 VS4 0.93
<TS 155 B
37 128 18 VS4
-0.76
<TS 156 B
37 128 21 VS4 1
<TS 157 B
37 148 28 VS4
-0.72
<TS 158 B
37 156 21 VS4
-0.97
<TS 159 B
37 156 26 VS4 0.94
<TS 160
- s.
37 160 18 02H 0.97
<TS 161 B
37 160 18 VS4
-0.37
<TS 162 B
37 160 23 VS4 1.1
<TS 163 B
38 5
16 02C
-0.91
<TS 164 B
38 9
14 03C
-1.05
<TS 165 B
38 13 20 VS4 0.7
<TS 166 B
38 39 16 02H 0.94
<TS 167 B
38 45 15 02C 0.09
<TS 168 B
38 49 29 VS4 0.8
<TS 169 B
38 49 11 02H
-0.86
<TS 170 B
38 49 19 VS4 0:18
<TS 171 B
38 51 13 VS4
-0.62
<TS 172 B
38 51 11 02C 0.83
<TS 173 B
38 53 13 03H
-0.81
<TS 174 B
38 53 21 VS4 0.04
<TS 175 B
38 53 18 VS4 0.69
<TS 176 B
38 107 20 02C 0.76
<TS 177 B
38 115 13 04C 0.78
<TS 178 B
38 125 21 VS4
-0.82
<TS 179 B
38 125 36 VS4 0.86
<TS 180 B
38 125 9
VS4
-0.02
<TS 181 B
38 127 24 VS4 0.87
<TS 182 B
38 127 15 02C
-0.96
<TS 183 B
38 127 11 04C 0.04
<TS 184 B
38 131 18 VS4 0.91
<TS 185 B
38 133 17 VS4
-0.78
<TS 186 B
38 145 23 VS4 1.14
<TS 187 B
38 147 33 VS4
-0.76
<TS 188 B
38 147 15 VS4 1.14
<TS 189 B
38 161 23 02H 0.89
<TS 190 B
39 6
15 02C
-0.2
<TS 191 B
39 6
11 02C 0.83
<TS 192 B
39 8
13 03C 0.77
<TS 193 B
39 8
15 03C
-0.98
<TS 194 B
39 10 12 03C 0.7
<TS 195 B
39 12 20 VS4
-0.46
<TS 196 B
39 22 14 DBC 1.52
<TS 197 B
39 50 11 VS4
-0.46
<TS 198 B
39 52 13 03H
-0.8
<TS 199 B
39 102 18 VS4
-0.68
<TS 200 B
39 108 13 DBH
-1.75
<TS 201 B
39 116 16 VS4
-0.77
<TS 202 B
39 116 35 VS4 0.93
<TS 203 B
39 120 25 VS4 0.91
<TS 204 B
39 122 28 VS4 0.8
<TS Page D-4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 205 B
39 122 13 02C
-0.96
<TS 206 B
39 134 25 VS4
-0.84
<TS 207 B
39 146 18 DBC 1.56
<TS 208 B
39 160 18 02H 0.88
<TS 209 B
40 5
17 02C
-0.94
<TS 210 B
40 31 13 03H 0.94
<TS 211 B
40 31 15 VS4 0.89
<TS 212 B
40 33 13 VS4 0.72
<TS 213 B
40 39 13 04H
-0.81
<TS 214 B
40 51 14 01H 0.92
<TS 215 B
40 55 12 03H
-0.82
<TS 216 B
40 115 12 03C 0.76
<TS 217 B
40 115 12 04C 0.74
<TS 218 B
40 117 18 03C 0.82
<TS 219 B
40 121 21 VS4
-0.8
<TS 220 B
40 121 28 VS4 1.04
<TS 221 B
40 123 19 VS4 1.02
<TS 222 B
40 123 13 03C
-1.02
<TS 223 B
40 125 20 02C
-0.92
<TS 224 B
40 129 17 04C
-0.8
<TS 225 B
40 143 18 05H 0.9
<TS 226 B
41 6
13 01C 0.74
<TS 227 B
41 6
13 01C
-1.05
<TS 228 B
41 8
20 04C 0.76
<TS 229 B
41 12 22 VS4 0.78
<TS 230 B
41 12 19 05C
-0.07
<TS 231 B
41 12 27 VS4 0.02
<TS 232 B
41 14 32 VS4 0.22
<TS 233 B
41 14 12 VS4 0.78
<TS 234 B
41 28 16 05H 0.96
<TS 235 B
41 32 23 VS4 0.07
<TS 236 B
41 32 7
VS4 0.67
<TS 237 B
41 36 13 03H
-0.49
<TS 238 B
41 40 9
02C
-0.24
<TS 239 B
41 48 12 VS4
-0.85
<TS 240 B
41 48 15 03H 0.92
<TS 241 B
41 54 18 VS4
-0.84
<TS 242 B
41 54 34 VS4 0.8
<TS 243 B
41 56 12 02H 0.89
<TS 244 B
41 120 7
05C 0.83
<TS 245 B
41 122 19 VS4
-0.91
<TS 246 B
41 122 12 VS4 0.65
<TS 247 B
41 128 15 04C
-0.99
<TS 248 B
41 132 17 VS4 0.89
<TS 249 B
41 132 18 04C 0.26
<TS 250 B
41 134 15 03C 0.75
<TS 251 B
42 27 21 VS4
-0.73
<TS 252 B
42 37 17 VS4
-0.02
<TS 253 B
42 39 18 VS4 0.18
<TS 254 B
42 41 37 VS4 0.85
<TS 255 B
42 41 30 VS4 0.22
<TS 256 B
42 47 13 03H
-0.79
<TS Page D-5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 257 B
42 51 37 VS4
-0.73
<TS 258 B
42 51 14 VS4
-0.18
<TS 259 B
42 51 25 VS4 0.93
<TS 260 B
42 57 38 VS4 0.75
<TS 261 B
42 57 20 VS4 0.2.
<TS 262 B
42 123 33 VS4 0.93
<TS 263 B
42 133 15 02H
-0.85
<TS 264 B
43 6
10 05H
-0.17
<TS 265 B
43 6
26 02C
-0.17
<TS 266 B
43 6
12 02C
-0.89
<TS 267 B
43 8
13 03C 0.72
<TS 268 B
43 42 14 05C 0.76
<TS 269 B
43 48 20 05C 0.8
<TS 270 B
43 126 19 04C
-0.92
<TS 271 B
43 132 17 VS4 0.87
<TS 272 B
43 134 15 03C
-1.04
<TS 273 B
44 19 13 VS4 0.27
<TS 274 B
44 21 23 VS4
-0.78
<TS 275 B
44 21 28 VS4 0.86
<TS 276 B
44 23 28 DBH
-1.64
<TS 277 B
44 23 14 VS4 0.87
<TS 278 B
44 27 26 VS4
-0.67
<TS 279 B
44 27 27 VS4 1.06
<TS 280 B
44 27 12 DBC
-1.46
<TS 281 B
44 29 14 VS4 0.7
<TS 282 B
44 29 32 VS4 0.07
<TS 283 B
44 29 17 VS4
-0.84
<TS 284 B
44 31 37 VS4
-0.58
<TS 285 B
44 31 21 VS4 0.11
<TS 286 B
44 31 20 DBC 1.37
<TS 287 B
44 31 18 02C 0.75
<TS 288 B
44 33 11 VS4 0.22
<TS 289 B
44 33 9
VS4 0.93
<TS 290 B
44 37 33 VS4 0.11
<TS 291 B
44 37 19 VS4 0.86
<TS 292 B
44 41 16 02C
-0.28
<TS 293 B
44 45 24 VS4 1
<TS 294 B
44 45 18 04C 0.79
<TS 295 B
44 45 15 03C 0.76
<TS 296 B
44 47 22 VS4
-0.58
<TS 297 B
44 47 22 VS4 0.2
<TS 298 B
44 53 10 VS4
-0.57
<TS 299 B
44 57 21 VS4
-0.69
<TS 300 B
44 57 13 VS4 0.13
<TS 301 B
44 59 14 VS4 0.83
<TS 302 B
44 59 25 VS4 0.06
<TS 303 B
44 63 11 VS4
-0.77
<TS 304 B
44 63 21 VS4 0.99
<TS 305 B
44 65 24 VS4 0
<TS 306 B
44 65 22 VS4 0.97
<TS 307 B
44 99 17 DBH 1.71
<TS 308 B
44 101 16 04C 0.79
<TS Page D-6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 309 B
44 103 33 VS4 0.96
<TS 310 B
44 107 25 VS4 0.98
<TS 311 B
44 107 19 VS4
-0.72
<TS 312 B
44 121 11 03C 0.78
<TS 313 B
44 127 21 02C 0.81
<TS 314 B
44 131 13 VS4 0.94
<TS 315 B
44 131 19 03C 0.8
<TS 316 B
44 137 13 04C
-0.96
<TS 317 B
44 159 16 01H
-0.92
<TS 318 B
45 6
24 02C
-0.22
<TS 319 B
45 6
28 02C
-0.96
<TS 320 B
45 16 10 DBH
-1.57
<TS 321 B
45 32 23 VS4
-0.69
<TS 322 B
45 32 23 VS4 0.35
<TS 323 B
45 32 22 VS4 1.02
<TS 324 B
45 34 20 VS4
-0.73
<TS 325 B
45 34 32 VS4 0.11
<TS 326 B
45 34 13 VS4 0.77
<TS 327 B
45 36 27 VS4 0.2
<TS 328 B
45 36 18 VS4 1.12
<TS 329 B
45 38 10 VS4
-0.49
<TS 330 B
45 38 12 VS4 0.38
<TS 331 B
45 42 24 VS4
-0.82
<TS 332 B
45 42 16 VS4 0.95
<TS 333 B
45 48 21 VS4 0.83
<TS 334 B
45 48 22 VS4 0.22
<TS 335 B
45 48 16 VS4
-0.76
<TS 336 B
45 56 13 03H 0.9
<TS 337 B
45 64 15 DBC
-1.86
<TS 338 B
45 66 14 VS4 0.67
<TS 339 B
45 66 19 VS4 0.02
<TS 340 B
45 108 11 03H 0.11
<TS 341 B
45 114 13 03C
'0.77
<TS 342 B
45 118 18 06H
-0.2
<TS 343 B
45 122 26 VS4
-0.8
<TS 344 B
45 122 32 VS4 1
<TS 345 B
45 126 18 02C 0.74
<TS 346 B
45 128 14 03H
-0.89
<TS 347 B
45 130 16 VS4 1.09
<TS 348 B
45 132 15 VS4 0.88
<TS 349 B
45 140 16 VS4
-0.87
<TS 350 B
45 140 31 VS4 0.8
<TS 351 B
45 140 13 06C
-0.57
<TS 352 B
45 140 18 DBH
-1.48
<TS 353 B
45 148 19 VS4 1.05
<TS 354 B
45 148 16 06C
-0.88
<TS 355 B
46 7
8 01C 0.72
<TS 356 B
46 7
23 01C
-0.31
<TS 357 B
46 7
17 06C 1.19
<TS 358 B
46 21 11 VS4 0.93
<TS 359 B
46 23 19 VS4
-0.98
<TS 360 B
46 23 23 VS4 0.84
<TS Page D-7
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 361 B
46 25 11 VS4
-0.63
<TS 362 B
46 33 13 DBC
-1.68
<TS 363 B
46 33 12 VS4 0
<TS 364 B
46 33 26 VS4
-0.86
<TS 365 B
46 35 22 VS4
-0.79
<TS 366 B
46 37 14 DBC
-1.63
<TS 367 B
46 37 20 VS4 0.88
<TS 368 B
46 37 15 VS4
-0.88
<TS 369 B
46 39 22 VS4 0.11
<TS 370 B
46 39 25 VS4 0.89
<TS 371 B
46 47 12 02H
-0.06
<TS 372 B
46 59 13 03C 0.82
<TS 373 B
46 69 14 DBH
-1.83
<TS 374 B
46 103 16 04C 0.83
<TS 375 B
46 125 14 02C
-0.96
<TS 376 B
46 129 22 VS4 0.72
<TS 377 B
46 129 13 03C 0.77
<TS 378 B
46 131 16 VS4
-0.86
<TS 379 B
46 131 12 VS4 0.2
<TS 380 B
46 143 13 DBC 1.27
<TS 381 B
46 151 35 VS4 0.92
<TS 382 B
47 8
9 01H 0.92
<TS 383 B
47 12 18 VS4
-0.75
<TS 384 B
47 12 25 VS4 1.1
<TS 385 B
47 14 25 VS4
-0.02
<TS 386 B
47 14 25 VS4 0.66
<TS 387 B
47 20 28 VS4
-0.8
<TS 388 B
47 20 30 VS4 0.97
<TS 389 B
47 22 18 VS4
-0.75
<TS 390 B
47 22 17 VS4 1.04
<TS 391 B
47 34 14 VS4 0.95
<TS 392 B
47 46 20 VS4
-0.61
<TS 393 B
47 46 22 VS4 0.11
<TS 394 B
47 46 12 VS4 0.95
<TS 395 B
47 56 30 VS4 1.06
<TS 396 B
47 56 18 VS4
-0.71
<TS 397 B
47 58 21 VS4 0.82
<TS 398 B
47 70 19 VS4
-0.63
<TS 399 B
47 96 16 VS4
-0.83
<TS 400 B
47 96 22 VS4 0.94
<TS 401 B
47 98 22 VS4 0.95
<TS 402 B
47 102 12 VS4
-0.9
<TS 403 B
47 108 27 06H 0.96
<TS 404 B
47 108 23 VS4
-0.96
<TS 405 B
47 108 21 VS4 0
<TS 406 B
47 108 26 VS4 0.96
<TS 407 B
47 114 15 06C 0.87
<TS 408 B
47 116 16 04C
-0.98
<TS 409 B
47 126 32 VS4
-0.77
<TS 410 B
47 126 32 VS4 1.1
<TS 411 B
47 128 26 VS4
-0.79
<TS 412 B
47 132 14 VS4
-0.81
<TS Page D-8
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 413 B
47 132 14 VS4 0.91
<TS 414 B
47 140 15 VS4 1.07
<TS 415 B
47 148 17 04C 0.89
<TS 416 B
48 7
12 01H 0.96
<TS 417 B
48 9
32 VS4
-0.65
<TS 418 B
48 9
30 VS4 0.31
<TS 419 B
48 9
20 VS4 0.92
<TS 420 B
48 13 23 VS4
-0.7
<TS 421 B
48 13 31 VS4 0.25
<TS 422 B
48 13 22 VS4 0.92
<TS 423 B
48 13 19 VS4
-0.11
<TS 424 B
48 65 27 VS4
-0.65
<TS 425 B
48 67 10 VS4 0.89
<TS 426 B
48 67 14 VS4 0.22
<TS 427 B
48 99 14 03C 0.79
<TS 428 B
48 107 17 04C 0.76
<TS 429 B
48 111 17 04C 0.81
<TS 430 B
48 123 14 VS4 0.87
<TS 431 B
48 125 16 03C 0.83
<TS 432 B
48 129 13 03C
-0.17
<TS 433 B
48 139 15 03H 1.02
<TS 434 B
48 159 11 01H
-0.96
<TS 435 B
49 8
24 VS4 0.89
<TS 436 B
49 10 22 01C 0.77
<TS 437 B
49 12 9
DBC 1.57
<TS 438 B
49 26 12 03H 0.92
<TS 439 B
49 34 13 VS4
-0.9
<TS 440 B
49 34 39 VS4 0.81
<TS 441 B
49 46 20 VS4
-0.63
<TS 442 B
49 56 11 03H
-0.89
<TS 443 B
49 74 24 DBH
-1.63
<TS 444 B
49 106 17 VS4 0.04
<TS 445 B
49 122 14 04C 0.76
<TS 446 B
49 124 22 VS4
-0.78
<TS 447 B
49 132 16 03C
-0.94
<TS 448 B
49 144 10 02H 0.78
<TS 449 B
49 158 18 01C 0.02
<TS 450 B
50 7
17 DBH 1.79
<TS 451 B
50 9
13 01C
-0.~7
<TS 452 B
50 63 15 DBH
-1.54
<TS 453 B
50 127 14 03C
-0.94
<TS 454 B
50 157 21 01H
-0.91
<TS 455 B
50 159 17 01C 0.81
<TS 456 B
51 36 13 03C
-0.96
<TS 457 B
51 36 11 03C 0.79
<TS 458 B
51 58 13 01H 0.88
<TS 459 B
51 58 13 03H 0.83
<TS 460 B
51 64 18 02C 0.91
<TS 461 B
51 72 12 VS3
-0.89
<TS 462 B
51 116 21 VS3
-0.94
<TS 463 B
51 134 15 03C
-0.95
<TS 464 B
51 156 25 VS5
-0.76
<TS Page D-9
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 465 B
52 25 15 02H 0.85
<TS 466 B
52 65 14 03C 0.78
<TS 467 B
52 107 16 02C 0.87
<TS 468 B
53 8
15 01C 0.7
<TS 469 B
53 56 13 03H 0.88
<TS 470 B
53 60 14 04H 1.03
<TS 471 B
53 80 17 03C 0.77
<TS 472 B
53 118 14 02C
-0.17
<TS 473 B
53 120 12 04C 0.81
<TS 474 B
53 128 17 03C 0.72
<TS 475 B
53 132 19 02C 0.78
<TS 476 B
53 134 14 03C 0.83
<TS 477 B
54 17 13 VS3
-0.83
<TS 478 B
54 17 14 VS3 1.04
<TS 479 B
54 71 14 02H 0.93
<TS 480 B
54 103 19 VS3
-0.67
<TS 481 B
54 117 16 02C 0.8
<TS 482 B
54 143 13 VS3
-0.77
<TS 483 B
55 32 16 VS3
-0.61
<TS 484 B
55 54 14 VS3
-0.87
<TS 485 B
55 56 12 03H 1.09
<TS 486 B
55 60 14 04H 0.88
<TS 487 B
55 64 16 02C 0.82
<TS 488 B
55 78 15 01C 0.82
<TS 489 B
55 96 12 01C 0.85
<TS 490 B
55 114 17 03C 0.78
<TS 491 B
55 120 15 04H
-0.86
<TS 492 B
55 126 11 03C 0.04
<TS 493 B
56 55 14 VS4
-0.65
<TS 494 B
56 59 11 04H 0.96
<TS 495 B
56 77 11 02C 0.71
<TS 496 B
56 85 17 02C
-0.98
<TS 497 B
56 85 24 03C 0.87
<TS 498 B
56 97 19 04C 0.85
<TS 499 B
56 129 15 VS3 0.9
<TS 500 B
56 129 20 03C 0.84
<TS 501 B
56 145 13 04C
-0.93
<TS 502 B
57 16 17 06H
-0.06
<TS 503 B
57 26 17 06H 0.92
<TS 504 B
57 62 17 04H 0.91
<TS 505 B
57 80 13 03C 0.73
<TS 506 B
57 90 14 03C
-1
<TS 507 B
57 90 22 03C 0.81
<TS 508 B
57 120 11 04C
-0.18
<TS 509 B
57 142 13 VS3 0.94
<TS 510 B
57 142 15 04C 0.67
<TS 511 B
57 144 13 04C 0.78
<TS 512 B
57 146 9
DBH 1.63
<TS 513 B
57 148 13 04C 0.8
<TS 514 B
58 25 9
06H 0.94
<TS 515 B
58 27 14 05H 0.99
<TS 516 B
58 47 11 03C
-0.99
<TS Page D-10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 517 8
58 57 15 06C 0.72
<TS 518 8
58 59 11 02H
-0.09
<TS 519 8
58 63 14 04H 0.85
<TS 520 8
58 117 15 06C 0.68
<TS 521 8
59 26 14 04H 0.86
<TS 522 8
59 26 13 03C 0.7
<TS 523 8
59 28 17 DBH 1.67
<TS 524 8
59 48 13 06H 1.07
<TS 525 8
59 48 21 03C 0.83
<TS 526 8
59 66 13 02H
-0.81
<TS 527 8
59 70 13 03H
-0.81
<TS 528 8
59 88 14 03C 0.85
<TS 529 8
59 116 16 03C 0.76
<TS 530 8
59 118 17 03C
-0.89
<TS 531 8
59 120 16 04H
-0.81
<TS 532 8
59 120 10 03C
-0.87
<TS 533 8
59 122 13 03C
-0.15
<TS 534 8
60 41 23 02H
-0.04
<TS 535 8
60 119 15 03C 0.76
<TS 536 8
60 133 18 03C
-0.89
<TS 537 8
61 12 15 06H
-0.13
<TS 538 8
61 28 17 DBC 2
<TS 539 8
61 28 12 04H
-0.84
<TS 540 8
61 42 15 VS3 0.74
<TS 541 8
61 48 8
VS3
-1.03
<TS 542 8
61 62 12 03H
-0.78
<TS 543 8
61 68 12 02H
-0.78
<TS 544 8
61 102 15 05C
-0.26
<TS 545 8
61 120 21 02C
-0.91
<TS 546 8
61 124 18 02C 0.8
<TS 547 8
61 142 17 03C 0.86
<TS 548 8
62 17 15 VS4
-0.59
<TS 549 8
62 17 13 VS5 1
<TS 550
- 8 62 23 11 VS5 0.97
<TS 551 8
62 39 7
04H
-0.15
<TS 552 8
62 47 10 DBC
-1.53
<TS 553 8
62 47 9
03C 0.73
<TS 554 8
62 53 9
06H 0.94
<TS 555 8
62 57 12 02H
-0.8
<TS 556 8
62 57 8
02C 0.74
.<TS 557 8
62 59 11 02C 0.74
<TS 558 8
62 85 12 DBC
-1.8
<TS 559 8
62 107 13 02C
-0.91
<TS 560 8
62 111 16 03H 0.19
<TS 561 8
62 155 11 01H
-0.79
<TS 562 8
62 155 14 01H
-0.06
<TS 563 8
62 155 12 01H 0.98
<TS 564 8
63 18 13 DBC
-0.57
<TS 565 8
63 28 9
06H
-0.87
<TS 566 8
63 56 15 03H
-0.76
<TS 567 8
63 56 15 04H
-0.91
<TS 568 8
63 56 17 03C 0.83
<TS Page D-11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 569 B
63 58 12 04H
-0.84
<TS 570 B
63 60 9
03C
-1.01
<TS 571 B
63 70 18 04H 0.98
<TS 572 B
63 78 9
03H
-0.89
<TS 573 B
63 82 28 VS4 1.03
<TS 574 B
63 82 13 VS5
-0.09
<TS 575 B
63 82 27 VS5 1.14
<TS 576 B
63 110 14 03H
-0.13
<TS 577 B
63 126 14 VS3 0.97
<TS 578 B
63 128 17 06C 0.77
<TS 579 B
63 136 18 VS5 1.01
<TS 580 B
63 136 16 03C 0.79
<TS 581 B
63 138 15 03C 0.77
<TS 582 B
63 140 14 06C
-0.22
<TS 583 B
63 140 22 03C 0.81
<TS 584 B
64 37 18 06H
-0.11
<TS 585 B
64 51 19 VS5
-0.04
<TS 586 B
64 51 16 VS5 0.8
<TS 587 B
64 103 10 04C 0.84
<TS 588 B
64 147 22 DBH 1.95
<TS 589 B
65 16 16 VS3
-0.73
<TS 590 B
65 16 13 06H
-0.22
<TS 591 B
65 32 12 VS3
-0.86
<TS 592 B
65 62 18 04H
-1.19
<TS 593 B
65 110 23 03H 0.94
<TS 594 B
65 118 16 02C 0.78
<TS 595 B
65 122 16 06C 0.85
<TS 596 B
65 122 16 02C 0.8
<TS 597 B
65 130 12 03C 0.85
<TS 598 B
66 17 13 06H 0.92
<TS 599 B
66 21 19 06H 0.83
<TS 600 B
66 27 8
06H
-0.76
<TS 601 B
66 27 9
06C 0.77
<TS 602 B
66 29 13 06C
-0.95
<TS 603 B
66 31 9
06C 0.83
<TS 604 B
66 35 18 06C 0.78
<TS 605 B
66 39 14 VS5
-0.81
<TS 606 B
66 41 12 VS3
-0.7
<TS 607 B
66 41 11 VS3
-0.18
<TS 608 B
66 41 12 VS4
-0.72
<TS 609 B
66 41 9
DBC
-1.77
<TS 610 B
66 45 11 06C 0.72
<TS 611 B
66 47 9
06C
-0.2
<TS 612 B
66 51 11 06H 1.01
<TS 613 B
66 51 10 06C 0.83
<TS 614 B
66 51 9
04C
-0.33
<TS 615 B
66 77 9
VS3
-0.76
<TS 616 B
66 97 12 01C 0.74
<TS 617 B
66 107 16 02H
-0.84
<TS 618 B
66 107 14 02C
-0.98
<TS 619 B
66 125 15 02C 0.81
<TS 620 B
66 137 13 03C 0.81
<TS Page D-12
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 621 B
66 143 14 VS5 0.89
<TS 622 B
66 149 14 06H 0.91
<TS 623 B
66 153 18 VS3 0.66
<TS 624 B
67 36 15 06H 0.95
<TS 625 B
67 46 12 DBC 1.86
<TS 626 B
67 56 11 02H 0.97
<TS 627 B
67 56 14 04H
-0.85
<TS 628 B
67 56 16 03C 0.77
<TS 629 B
67 56 14 02C 0.83
<TS 630 B
67 58 19 03C 0.81
<TS 631 B
67 62 20 03C 0.74
<TS 632 B
67 62 16 02C
-0.2
<TS 633 B
67 74 13 04H
-0.82
<TS 634 B
67 76 15 02H
-0.78
<TS 635 B
67 104 12 03H 1
<TS 636 B
67 104 7
04H 0.94
<TS 637 B
67 104 21 06C
-0.24
<TS 638 B
67 108 13 03H 0.96
<TS 639 B
67 128 23 VS3 1.01
<TS 640 B
67 128 15 06H 0.26
<TS 641 B
67 134 28 06C
-1.03
<TS 642 B
67 134 16 03C 0.74
<TS 643 B
67 136 23 DBH
-1.8
<TS 644 B
67 138 28 VS3 0.3
<TS 645 B
67 138 28 03C 0.46
<TS 646 B
67 148 23 DBH 1.75
<TS 647 B
67 148 14 VS3 1.03
<TS 648 B
67 150 18 VS3
-0.53
<TS 649 B
67 150 22 VS3 1.07
<TS 650 B
68 17 15 04H 0.84
<TS 651 B
68 21 17 VS5
-0.78
<TS 652 B
68 41 20 04H 0.93
<TS 653 B
68 45 13 DBC
-1.56
<TS 654 B
68 85 12 02C
-0.85
<TS 655 B
68 93 21 04C
-0.96
<TS 656 B
68 93 16 04C
-0.18
<TS 657 B
68 109 19 02H 0.9
<TS 658 B
68 113 22 04H 0.95
<TS 659 B
68 113 11 04H
-0.8
<TS 660 B
68 113 15 03H 0.86
<TS 661 B
68 143 19 06H 0.92
<TS 662 B
68 151 22 VS3
-0.34
<TS 663 B
69 16 17 VS3
-0.67
<TS 664 B
69 28 17 06C 0.89
<TS 665 B
69 28 13 06H
-0.15
<TS 666 B
69 28 14 06H
-0.93
<TS 667 B
69 34 19 DBC 1.29
<TS 668 B
69 36 8
DBC 1.73
<TS 669 B
69 36 9
04C 0.81
<TS 670 B
69 48 8
04C 0
<TS 671 B
69 52 18 VS3 0.07
<TS 672 B
69 52 20 VS4
-0.63
<TS Page D-13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 673 B
69 52 12 VS4
-0.04
<TS 674 8
69 52 14 VS5
-0.85
<TS 675 8
69 52 15 VS5 0.92
<TS 676 B
69 56 11 VS5
-0.74
<TS 677 B
69 56 14 VS5 0.98
<TS 678 8
69 72 11 03H 0.88
<TS 679 B
69 72 16 06C
-1
<TS 680 B
69 102 10 03H 0.96
<TS 681 B
69 106 16 06H
-0.73
<TS 682 B
69 110.
16 03C 0.74
<TS 683 B
69 120 20 03C 0.78
<TS 684 B
69 120 14 03C 0.02
<TS 685 B
69 124 17 03C
-0.87
<TS 686 B
69 128 16 03C 0.8
<TS 687 B
69 132 14 04H 0.92
<TS 688 B
69 134 13 VS3
-0.7
<TS 689 B
69 134 33 VS4
-0.91
<TS 690 B
69 134 28 VS4 1.09
<TS 691 B
69 134 13 VS5
-0.8
<TS 692 B
69 136 22 VS5
-0.7
<TS 693 B
69 136 13 VS5 1.02
<TS 694 B
69 140 12 VS3 1.11
<TS 695 8
69 140 12 VS4 0.96
<TS 696 B
69 140 23 VS5
-0.78
<TS 697 B
69 144 20 VS3
-0.69
<TS 698 8
69 144 28 VS5
-0.8
<TS 699 B
69 150 30 VS3
-0.59
<TS 700 B
69 150 19 VS3 1.06
<TS 701 B
69 150 18 VS5 0.89
<TS 702 8
70 31 9
06C 0.79
<TS 703 8
70 45 12 03H 0.91
<TS 704 B
70 47 9
04C
-0.24
<TS 705 B
70 51 12 03C 0.79
<TS 706 8
70 75 16 03H
-0.07
<TS 707 B
70 83 14 02C 0.76
<TS 708 B
70 107 15 02H
-0.82
<TS 709 8
70 129 21 06C
-0.98
<TS 710 B
70 141 20 VS3
-0.85
<TS 711 8
70 143 22 DBC 1.17
<TS 712 8
70 147 16 VS3
-0.79
<TS 713 B
70 153 18 VS4 1.07
<TS 714 B
70 153 16 VS4
-0.75
<TS 715 B
70 153 22 03C 0
<TS 716 8
71 14 16 02H
-0.8
<TS 717 B
71 20 17 DBH
-1.73
<TS 718 B
71 20 15 VS5 0.9
<TS 719 8
71 20 13 DBC 1.43
<TS 720 8
71 36 19 VS3 0.07
<TS 721 B
71 36 22 VS3 0.78
<TS 722 B
71 36 16 VS5
-0.67
<TS 723 8
71 36 28 VS5 0.02
<TS 724 B
71 36 10 DBC 1.93
<TS Page D-14
A Document No.: 51-9252894-001
.AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 725 B
71 36 12 DBC
-1.84
<TS 726 B
71 36 12 06C 0.74
<TS 727 B
71 38 14 05H 1
<TS 728 B
71 42 9
04H
-0.81
<TS 729 B
71 46 7
04H
-0.76
<TS 730 B
71 52 17 03C 0.81
<TS 731 B
71 52 10 02C
-0.96
<TS 732 B
71 58 12 02C
-0.18
<TS 733 B
71 62 14 03C
-0.19
<TS 734 B
71 80 15 03C 0.16
<TS 735 B
71 86 18 VS5
-0.76
<TS 736 B
71 86 12 02C
-0.24
<TS 737 B
71 86 17 02C
-0.96
<TS 738 B
71 102 16 05C 0.83
<TS 739 B
71 104 9
02H 0.83
<TS 740 B
71 110 11 04H
-0.84
<TS 741 B
71 112 15 04C 0.76
<TS 742 B
71 132 15 VS5 1.01
<TS 743 B
71 136 12 06C
-0.11
<TS 744 B
71 136 21 06C
-0.92
<TS 745 B
71 142 18 DBC 1.26
<TS 746 B
71 144 32 VS3
-0.79
<TS 747 B
71 144 24 DBC 1.91
<TS 748 B
71 144 21 VS3 0.99
<TS 749 B
71 146 15 06H 0.28
<TS 750 B
71 146 32 VS5
-0.79
<TS 751 B
72 17 23 DBH 1.51
<TS 752 B
72 19 15 VS3 0.22
<TS 753 B
72 23 17 VS3 0.78
<TS 754 B
72 25 24 VS3
-0.81
<TS 755 B
72 25 10 DBC 1.87
<TS 756 B
72 41 25 06C 0.78
<TS 757 B
72 47 15 03C
-0.99
<TS 758 B
72 49 31 03C 0.83
<TS 759 B
72 55 18 VS3
-0.85
<TS 760 B
72 57 13 03C
-0.94
<TS 761 B
72 59 16 04C 0.77
<TS 762 B
72 61 15 02C 0.75
<TS 763 B
72 63 14 02C 0.77
<TS 764 B
72 85 15 05C 0.81
<TS 765 B
72 113 15 04C 0.81
<TS 766 B
72 113 13 04H 0.95
<TS 767 B
72 113 9
02H 0.94
<TS 768 B
72 113 15 02H
-0.8
<TS 769 B
72 125 26 06C 0.87
<TS 770 B
72 149 31 DBH 1.67
<TS 771 B
72 149 19 VS3 0.9
<TS 772 B
73 14 9
VS4
-1.03
<TS 773 B
73 14 9
VS4 0.26
<TS 774 B
73 20 14 VS5 0.87
<TS 775 B
73 40 11 05H 1
<TS 776 B
73 58 17 06C
-0.24
<TS Page D-15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 777 S
73 58 14 02C
-0.15
<TS 778 S
73 86 13 02C
-0.95
<TS 779 S
73 104 19 06C
-0.98
<TS 780 S
73 106 13 03H 0.97
<TS 781 S
73 132 12 06H 0.96
<TS 782 S
74 17 23 VS3
-0.7
<TS 783 S
74 17 12 VS3 1
<TS 784 S
74 17 22 VS4
-0.88
<TS 785 S
74 19 15 VS4
-0.87
<TS 786 S
74 19 16 DSC
-1.76
<TS 787 S
74 21 13 VS3 0.98
<TS 788 S
74 23 15 VS3
-1.08
<TS 789 S
74 23 16 VS4
-0.68
<TS 790 S
74 23 14 DSC 1.54
<TS 791 S
74 37 12 06H 0.94
<TS 792 S
74 37 11 DSC 1.7
<TS 793 S
74 37 10 04C
-0.96
<TS 794 S
74 43 11 VS3
-0.92
<TS 795 S
74 43 18 VS4
-0.7
<TS 796 S
74 45 16 VS5
-0.81
<TS 797 S
74 47 7
06C 0
<TS 798 S
74 51 9
03C
-0.96
<TS 799 S
74 53 9
VS3
-0.83
<TS 800 S
74 55 16 04C 0.83
<TS 801 S
74 71 15 03H 0.87
<TS 802 S
74 107 14 04H
-0.9
<TS 803 S
74 117 18 VS3
-1.02
<TS 804 S
74 119 15 04H 1
<TS 805 S
74 119 15 03H 0.9
<TS 806 S
74 127 18 DSH
-1.61
<TS 807 S
74 141 19 VS5
-0.72
<TS 808 S
75 16 12 02H 0.86
<TS 809 S
75 16 11 06H 0.98
<TS 810 S
75 24 13 VS3 0.2
<TS 811 S
75 24 14 DSC
-1.32
<TS 812 S
75 36 19 VS3 0.83
<TS 813 S
75 42 15 04C 0.7
<TS 814 S
75 60 16 03C 0.79
<TS 815 S
75 84 9
02C 0.76
<TS 816 S
75 102 17 04H 1.01
<TS 817 S
75 104 16 03H 0.94
<TS 818 S
75 106 14 02H
-0.84
<TS 819 S
75 112 13 03H
-0.88
<TS 820 S
75 132 11 06H
-0.91
<TS 821 S
75 132 12 DSH
-1.68
<TS 822 S
76 15 21 DSH 1.73
<TS 823 S
76 21 28 VS4 0.92
<TS 824 S
76 21 17 VS4
-0.83
<TS 825 S
76 21 15 VS3 0.96
<TS 826 S
76 25 17 06H 0.98
<TS 827 S
76 29 21 VS4 0
<TS 828 S
76 29 20 VS3 0.63
<TS Page D-16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 829 B
76 29 20 VS3 0.07
<TS 830 B
76 29 14 VS3
-0.85
<TS 831 B
76 33 19 DBH 1.87
<TS 832 B
76 35 20 DBH 1.73
<TS 833 B
76 41 13 05C
-0.99
<TS 834 B
76 41 13 03C
-0.17
<TS 835 B
76 51 22 VS3 0.74
<TS 836 B
76 55 20 DBH 1.53
<TS 837 B
76 59 16 05H 0.93
<TS 838 B
76 59 17 VS3
-0.85
<TS 839 B
76 65 10 VS4
-0.09
<TS 840 B
76 73 8
02H
-0.09
<TS 841 B
76 113 13 04H 0.11
<TS 842 B
76 117 13 DBC
-1.14
<TS 843 B
76 121 17 04C 0.89
<TS 844 B
76 127 17 DBH
-1.51
<TS 845 B
76 141 26 DBH 1.93
<TS 846 B
76 151 17 04C 0.81
<TS 847 B
77 34 21 VS3 0.75
<TS 848 B
77 34 8
VS3 0.09
<TS 849 B
77 48 17 VS4 1
<TS 850 B
77 50 12 05H
-0.8
<TS 851 B
77 56 10 DBH 0.84
<TS 852 B
77 86 15 02C 0.81
<TS 853 B
77 86 10 02C
-0.98
<TS 854 B
77 104 20 05H 0.91
<TS 855 B
77 104 21 05C 0.81
<TS 856 B
77 116 19 04H
-0.84
<TS 857 B
77 150 19 DBH 1.2
<TS 858 B
77 150 24 VS4
-0.72
<TS 859 B
77 150 22 VS4 0.98
<TS 860 B
78 23 19 DBH
-1.72
<TS 861 B
78 23 13 VS5 1.09
<TS 862 B
78 35 15 DBH
-1.39
<TS 863 B
78 47 19 02C 0.82
<TS 864 B
78 57 19 03C 0.79
<TS 865 B
78 61 21 VS3
-0.94
<TS 866 B
78 79 16 VS4 0.97
<TS 867 B
78 81 15 03H 1
<TS 868 B
78 87 15 03C
-0.91
<TS 869 B
78 91 18 07H 1.53
<TS 870 B
78 105 11 02H
-0.75
<TS 871 B
78 109 15 03H 0.96
<TS 872 B
78 109 10 03H 0.19
<TS 873 B
78 109 15 02H
-0.84
<TS 874 B
79 24 13 VS3
-0.59
<TS 875 B
79 24 13 VS3 1.07
<TS 876 B
79 24 27 VS4 0.11
<TS 877 B
79 24 29 VS4 0.85
<TS 878 B
79 30 12 DBC 1.61
<TS 879 B
79 44 14 03C 0.79
<TS 880 B
79 52 16 02C
-0.22
<TS Page D-17 I
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 881 B
79 54 13 03C 0.76
<TS 882 B
79 60 8
03C
-0.98
<TS 883 B
79 62 14 02C
-0.19
<TS 884 B
79 62 13 04C
-1.02
<TS 885 B
79 78 12 VS5 0.8
<TS 886 B
79 86 19 03H 0.8
<TS 887 B
79 122 18 03H 0.85
<TS 888 B
79 128 12 03C 0.78
<TS 889 B
80 17 29 DBH 1.68
<TS 890 B
80 49 16 VS4
-0.83
<TS 891 B
80 49 16 VS3
-0.89
<TS 892 B
80 95 20 04H 0.93
<TS 893 B
80 95 15 02H 0.88
<TS 894 B
80 95 16 03H 0.92
<TS 895 B
80 97 14 VS3
-0.13
<TS 896 B
80 115 22 VS4
-0.76
<TS 897 B
80 145 21 VS5 1.1
<TS 898 B
80 145 14 VS5
-0.62
<TS 899 B
80 145 33 VS4
-0.6
<TS 900 B
80 149 16 01H
-0.83
<TS 901 B
81 22 27 VS4 0.84
<TS 902 B
81 22 29 VS3 0.86
<TS 903 B
81 24 14 VS3 0.99
<TS 904 B
81 24 18 VS3
-0.86
<TS 905 B
81 52 33 VS3 0.78
<TS 906 B
81 60 14 03C 0.79
<TS 907 B
81 92 14 02C
-0.94
<TS 908 B
81 112 15 02H 0.94
<TS 909 B
81 126 18 07C 0.97
<TS 910 B
81 148 14 VS4
-0.85
<TS 911 B
81 148 15 VS4 0.94
<TS 912 B
81 148 20 04C
. 0.72
<TS 913 B
81 148 11 03C 0.73
<TS 914 B
82 19 14 03H 0.82
<TS 915 B
82 19 14 04H 0.91
<TS 916 B
82 19 10 VS4 1
<TS 917 B
82 21 12 VS5
-0.7
<TS 918 B
82 41 22 VS3 1
<TS 919 B
82 43 9
VS3
-0.81
<TS 920 B
82 43 27 VS3 0
<TS 921 B
82 43 20 VS3 0.75
<TS 922 B
82 43 9
VS4
-0.79
<TS 923 B
82 43 17 VS4 0.81
<TS 924 B
82 43 13 VS4
-0.02
<TS 925 B
82 43 24 VS5
-0.66
<TS 926 B
82 43 19 VS5
-0.13
<TS 927 B
82 43 22 VS5 0.28
<TS 928 B
82 43 12 VS5 0.88
<TS 929 B
82 59 11 02C 0.81
<TS 930 B
82 91 14 04C
-0.92
<TS 931 B
82 105 11 02H 1.04
<TS 932 B
82 129 16 DBH 1.88
<TS Page D-18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 933 B
82 137 20 DBH 1.71
<TS 934 B
82 143 27 VS3
-0.85
<TS 935 B
82 143 20 VS4
-0.76
<TS 936 B
82 145 20 VS3
-0.83
<TS 937 B
82 145 20 VS3 0.94
<TS 938 B
82 145 18 VS4
-0.78
<TS 939 B
82 145 27 VS4 0.87
<TS 940 B
83 20 11 DBH 1.79
<TS 941 B
83 28 20 VS6
-0.88
<TS 942 B
83 28 20 VS6 0.88
<TS 943 B
83 54 13 04H 0.94
<TS 944 B
83 64 17 03C 0.84
<TS 945 B
83 106 11 03H 0.9
<TS 946 B
83 148 30 VS4
-0.99
<TS 947 B
84 19 19 07H
-1.1
<TS 948 B
84 25' 12 VS2
-0.79
<TS 949 B
84 55 15 02C 0.78
<TS 950 B
84 77 14 05C
-0.95
<TS 951 B
84 79 12 03H 0.99
<TS 952 B
84 81 14 VS5
-0.83
<TS 953 B
84 81 15 02C 0.79
<TS 954 B
84 87 18 03H 0.93
<TS 955 B
84 93 20 02C
-0.96
<TS 956 B
84 107 15 02H
-0.77
<TS 957 B
84 125 14 04H
-0.81
<TS 958 B
84 145 17 03C
-0.87
<TS 959 B
84 147 27 DBH 1.8
<TS 960 B
85 20 16 VS4 0.98
<TS 961 B
85 20 12 VS4
-0.72
<TS 962 B
85 36 12 04H
-0.8
<TS 963 B
85 36 17 VS6
-0.8
<TS 964 B
85 78 17 05H 0.99
<TS 965 B
85 110 15 04C 0.78
<TS 966 B
85 140 12 04C 0.85
<TS 967 B
85
. 142 17 03C
-0.85
<TS 968 B
85 144 15 03C
-0.89
<TS 969 B
85 146 13 04C
-0.94
<TS 970 B
86 51 17 03C 0.89
<TS 971 B
86 61 8
02C 0.07
<TS 972 B
86 79 16 04H 0.9
<TS 973 B
86 89 16 03C 0.79
<TS 974 B
86 91 10 03C
-0.94
<TS 975 B
86 111 14 04C
-0.95
<TS 976 B
87 20 15 VS4
-0.91
<TS 977 B
87 30 13 04H 0.93
<TS 978 B
87 38 12 VS6
-0.78
<TS 979 B
87 62 15 04C
-0.93
<TS 980 B
87 82 15 03H 0.91
<TS 981 B
87 84 16 02C 0.78
<TS 982 B
87 88 20 04C
-0.85
<TS 983 B
87 146 33 03C 0.69
<TS 984 B
87 146 18 VS4 1
<TS Page D-19
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 985 B
87 146 22 VS4
-0.77
<TS 986 B
88 27 22 DBH 1.99
<TS 987 B
88 27 14 04H 0.87
<TS 988 B
88 29 14 06H 0.97
<TS 989 B
88 67 14 VS2 0.82
<TS 990 B
88 67 13 VS2
-0.7
<TS 991 B
88 79 16 07C 0.84
<TS 992 B
88 87 18 05C 0.83
<TS 993 B
88 95 26 03C 0.78
<TS 994 B
88 107 14 04C
-0.98
<TS 995 B
89 38 8
05H
-0.78
<TS 996 B
89 38 11 VS2
-0.82
<TS 997 B
89 42 10 VS6 0.88
<TS 998 B
89 44 11 VS6
-0.84
<TS 999 B
89 56 13 02C 0.78
<TS 1000 B
89 58 10 DBC 1.73
<TS 1001 B
89 60 14 04C
-0.89
<TS 1002 B
89 78 15 07C 0.77
<TS 1003 B
89 82 16 07C 0.77
<TS 1004 B
89 84 17 03H 0.86
<TS 1005 B
89 92 18 04C 0.35
<TS 1006 B
89 100 16 03H 0.9
<TS 1007 B
89 104 16 04H 0.95
<TS 1008 B
89 104 13 05C
-0.92
<TS 1009 B
89 104 14 04C
-0.98
<TS 1010 B
90 23 12 VS4
-0.87
<TS 1011 B
90 55 17 VS2 0.96
<TS 1012 B
90 57 16 02C 0.76
<TS 1013 B
90 65 17 03C 0.77
<TS 1014 B
90 87 12 02C
-0.2
<TS 1015 B
90 87 11 02C
-0.96
<TS 1016 B
90 95 16 04C 0.81
<TS 1017 B
90 97 16 04C 0.83
<TS 1018 B
90 115 13 03H
-0.84
<TS 1019 B
90 127 16 04H
-0.85
<TS 1020 B
90 131 13 07H 1
<TS 1021 B
91 22 26 VS6 1.01
<TS 1022 B
91 32 18 02C
-0.9
<TS 1023 B
91 38 15 03H
-0.84
<TS 1024 B
91 54 16 02C 0.91
<TS 1025 B
91 58 15 03C 0.78
<TS 1026 B
91 60 12 04C
-0.96
<TS 1027 B
91 64 20 03C
-0.98
<TS 1028 B
91 70 11 06C
-0.86
<TS 1029 B
91 86 19 VS6 0.9
<TS 1030 B
91 88 18 04H
-0.73
<TS 1031 B
91 94 18 06C
-0.92
<TS 1032 B
91 124 20 04C 0.76
<TS 1033 B
91 144 21 VS4 0.87
<TS 1034 B
91 144 20 VS4
-0.89
<TS 1035 B
92 23 9
03H
-0.74
<TS 1036 B
92 23 7
VS4
-0.98
<TS Page D-20
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1037 B
92 23 10 VS4 0.76
<TS 1038 B
92 23 11 02C 0.74
<TS 1039 B
92 23 8
02C
-0.99
<TS 1040 B
92 31 13 VS2
-0.81
<TS 1041 B
92 31 9
VS2 0.87
<TS 1042 B
92 49 13 05H 0.89
<TS 1043 B
92 55 15 03C 0.74
<TS 1044 B
92 57 16 04H 0.85
<TS 1045 B
92 61 13 03C
-0.91
<TS 1046 B
92 69 17 04C 0.81
<TS 1047 B
92 73 13 VS2 0.84
<TS 1048 B
92 75 12 05H 1
<TS 1049 B
92 83 20 05H 0.93
<TS 1050 B
92 97 15 04C 0.76
<TS 1051 B
92 97 10 04C 0.02
<TS 1052 B
92 105 14 04C
-0.94
<TS 1053 B
93 30 18 VS4
-1.01
<TS 1054 B
93 42 14 VS2 0.82
<TS 1055 B
93 56 11 02C 0.82
<TS 1056 B
93 62 12 02C 0.83
<TS 1057 B
93 62 13 03C 0.81
<TS 1058 B
93 98 14 04C
-0.96
<TS 1059 B
93 104 14 04H
-0.8
<TS 1060 B
93 112 17 VS6 0.82
<TS 1061 B
93 132 14 04H 0.9
<TS 1062 B
94 37 18 VS2
-0.65
<TS 1063 B
94 57 18 02C 0.8
<TS 1064 B
94 81 15 02C 0.81
<TS 1065 B
94 93 12 04C
-0.17
<TS 1066 B
94 93 9
04C
-0.93
<TS 1067 B
94 101 15 06H
-0.81
<TS 1068 B
94 111 15 VS6
-0.64
<TS 1069 B
94 115 17 04C
-1
<TS 1070 B
94 129 18 04H 0.89
<TS 1071 B
94 131 13 03C
-0.89
<TS 1072 B
95 24 14 VS4
-0.66
<TS 1073 B
95 24 12 VS4
-0.09
<TS 1074 B
95 24 12 VS4 0.81
<TS 1075 B
95 36 14 VS4
-0.85
<TS 1076 B
95 36 15 VS4 0.95
<TS 1077 B
95 42 16 DBC
-0.5
<TS 1078 B
95 70 14 04H 0.92
<TS 1079 B
95 70 17 VS6
-0.75
<TS 1080 B
95 84 22 07C 0.79
<TS 1081 B
95 102 19 05H 0.89
<TS 1082 B
95 104 11 03C 0.04
<TS 1083 B
95 106 20 04C
-1
<TS 1084 B
95 116 24 VS2
-0.96
<TS 1085 B
95 126 11 04H 0.9
<TS 1086 B
95 134 14 VS2 0.13
<TS 1087 B
95 134 20 VS2 1.05
<TS 1088 B
95 136 19 03C
-0.35
<TS Page D-21
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1089 8
95 138 37 VS4 0.96
<TS 1090 8
95 140 18 03C
-0.96
<TS 1091 8
95 142 20 VS4 1.02
<TS 1092 8
96 25 10 02H
-0.93
<TS 1093 8
96 29 19 VS4 0.89
<TS 1094 8
96 57 13 02H 0.83
<TS 1095 8
96 57 18 VS4 1.07
<TS 1096 8
96 65 11 04C 0.74
<TS 1097 8
96 65 11 02C 0.79
<TS 1098 8
96 71 9
04H
-0.09
<TS 1099 8
96 71 16 04H
-0.94
<TS 1100 8
96 79 12 VS2 0.64
<TS 1101 8
96 95 22 VS2
-0.77
<TS 1102 8
96 95 15 VS2 0.17
<TS 1103 8
96 95 19 VS2 1.03
<TS 1104 8
96 117 21 VS2 0.81
<TS 1105 8
96 137 18 VS4
-0.15
<TS 1106 8
96 137 24 VS4 0.95
<TS 1107 8
96 137 20 04C
-0.24
<TS 1108 8
96 137 14 03C 0.76
<TS 1109 8
96 139 21 03C
-0.95
<TS 1110 8
96 141 24 VS4 0.9
<TS 1111 8
97 26 15 VS4
-0.59
<TS 1112 8
97 28 20 03C 0.77
<TS 1113 8
97 38 13 05H 0.93
<TS 1114 8
97 40 12 VS2
-0.78
<TS 1115 8
97 42 15 VS2
-0.88
<TS 1116 8
97 60 19 VS2 0.95
<TS 1117 8
97 60 19 06C
- o.67
<TS 1118 8
97 72 15 04H 0.96
<TS 1119 8
97 84 11 07C
-0.17
<TS 1120 8
97 84 16 07C
-1
<TS 1121 8
97 130 13 04H 0.92
<TS 1122 8
97 140 13 VS4
-0.8
<TS 1123 8
98 27 11 VS4
-0.87
<TS 1124 8
98 27 13 VS4 1.05
<TS 1125 8
98 27 19 04C
-1.01
<TS 1126 8
98 39 14 VS4 0.69
<TS 1127 8
98 41 10 VS2
-0.78
<TS 1128 8
98 41 23 VS4 0.82
<TS 1129 8
98 41 17 VS2 0.91
<TS 1130 8
98 49 20 VS2
-0.43
<TS 1131 8
98 55 32 VS2
-0.83
<TS 1132 8
98 59 17 VS2
-0.84
<TS 1133 8
98 59 14 VS2 0.92
<TS 1134 8
98 71 16 VS2 0.98
<TS 1135 8
98 71 8
VS2
-0.73
<TS 1136 8
98 79 15 D3C 0.83
<TS 1137 8
98 79 11 03C 0.07
<TS 1138 8
98 81 17 VS2 0.89
<TS 1139 8
98 117 17 VS2 0.88
<TS 1140 8
98 133 14 02C 0.8
<TS Page D-22
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1141 B
98 135 20 VS2 0.11
<TS 1142 B
98 135 27 VS4
-0.75
<TS 1143 B
98 135 25 VS4 0.99
<TS 1144 B
98 137 22 DBH 1.82
<TS 1145 B
98 139 19 03C
-0.87
<TS 1146 B
98 139 23 VS4 0.82
<TS 1147 B
98 139 15 04H
-0.15
<TS 1148 B
98 139 28 VS4 0.21
<TS 1149 B
99 32 15 02C 0.85
<TS 1150 B
99 50 22 05H 0.61
<TS 1151 B
99 52 12 03C 0.76
<TS 1152 B
99 132 25 VS2
-0.77
<TS 1153 B
99 132 16 VS2
-0.21
<TS 1154 B
99 132 29 VS2 0.73
<TS 1155 B
99 132 19 VS4 0.9
<TS 1156 B
99 136 18 04C 0.81
<TS 1157 B
100 27 20 VS4
-1
<TS 1158 B
100 27 10 VS4 0.85
<TS 1159 B
100 29 19 03C 0.77
<TS 1160 B
100 29 20 VS6
-0.85
<TS 1161 B
100 109 23 VS2
-0.71
<TS 1162 B
100 121 18 06C 0.84
<TS 1163 B
100 125 36 VS2
-0.71
<TS 1164 B
100 125 38 VS2 0.02
<TS 1165 B
100 125 18 VS2 0.78
<TS 1166 B
100 125 27 VS4 1.03
<TS 1167 B
100 125 27 VS6
-0.09
<TS 1168 B
100 125 24 VS6 0.95
<TS 1169 B
100 125 19 DBC
-1.47
<TS 1170 B
100 133 17 VS4
-0.73
<TS 1171 B
101 28 15 VS4
-0.68
<TS 1172 B
101 28 12 VS4 0
<TS 1173 B
101 30 11 03H
-0.83
<TS 1174 B
101 30 17 04C 0.83
<TS 1175 B
101 30 12 03C 0.77
<TS 1176 B
101 30 17 03C
-0.96
<TS 1177 B
101 32 19 VS2 0.72
<TS 1178 B
101 36 12 05H 0.92
<TS 1179 B
101 38 12 DBC 1.69
<TS 1180 B
101 54 19 02C 0.76
<TS 1181 B
101 78 14 05H 0.91
<TS 1182 B
101 98 17 04C
-1.09
<TS 1183 B
101 104 24 DBH 1.78
<TS 1184 B
101 136 18 03H 0.83
<TS 1185 B
102 31 21 02C
-1.01
<TS 1186 B
102 33 19 03C
-0.96
<TS 1187 B
102 35 23 03C 0.77
<TS 1188 B
102 41 14 06H 0.99
<TS 1189 B
102 49 13 VS2 0.91
<TS 1190 B
102 51 16 07C 0.83
<TS 1191 B
102 85 29 VS6
-0.73
<TS 1192 B
102 99 8
07C 0.04
<TS Page D-23
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1193 B
102 99 15 07C 0.71
<TS 1194 B
102 113 19 DBH 1.91
<TS 1195 B
102 127 15 VS4 0.73
<TS 1196 B
102 131 14 DBC 1.7
<TS 1197 B
102 137 22 VS4 1.01
<TS 1198 B
102 137 16 VS4
-0.65
<TS 1199 B
103 30 13 01C 0.07
<TS 1200 B
103 30 14 06C
-0.95
<TS 1201 B
103 36 8
07H 0.98
<TS 1202 B
103 36 12 07C 0.85
<TS 1203 B
103 48 14 VS4
-0.74
<TS 1204 B
103 48 9
DBC
-1.35
<TS 1205 B
103 48 10 07C 0.17
<TS 1206 B
103 62 18 03C 0.72
<TS 1207 B
103 64 30 VS2 0.85
<TS 1208 B
103 94 21 VS2
-0.9
<TS 1209 B
103 100 16 07C 0.73
<TS 1210 B
103 108 27 VS6
-0.69
<TS 1211 B
103 122 18 03H 0.84
<TS 1212 B
103 126 26 VS2 0.19
<TS 1213 B
103 126 21 VS4
-0.6
<TS 1214 B
103 126 34 VS6 0.91
<TS 1215 B
103 128 15 04C 0.76
<TS 1216 B
103 130 21 VS2
-0.04
<TS 1217 B
103 132 11 04H 0.96
<TS 1218 B
103 132 22 VS2 0
<TS 1219 B
103 136 24 VS4 1.05
<TS 1220 B
103 136 22 VS4
-0.73
<TS 1221 B
104 31 22 VS4 0.72
<TS 1222 B
104 31 18 02C
-0.24
<TS 1223 B
104 33 13 03H 0.15
<TS 1224 B
104 59 15 VS6
-0.88
<TS 1225 B
104 59 16 VS4 0.94
<TS 1226 B
104 79 16 VS6
-0.73
<TS 1227 B
104 91 14 VS2
-0.67
<TS 1228 B
104 95 17 VS2
-0.62
<TS 1229 B
104 95 18 VS2 0.09
<TS 1230 B
104 95 20 VS2 0.88
<TS 1231 B
104 117 14 05C 0.83
<TS 1232 B
104 131 12 03C 0.74
<TS 1233 B
105 30 13 VS4 0.22
<TS 1234 B
105 30 27 VS4 0.76
<TS 1235 B
105 30 17 02C 0.7
<TS 1236 B
105 32 11 01H 0.96
<TS 1237 B
105 32 8
VS4
-0.82
<TS 1238 B
105 32 10 VS4 1.13
<TS 1239 B
105 34 19 02C 0.09
<TS 1240 B
105 36 12 04H
-0.13
<TS 1241 B
105 38 21 03C 0.83
<TS 1242 B
105 40 10 03C
-0.98
<TS 1243 B
105 42 12 07C 0.73
<TS 1244 B
105 54 21 VS6
-0.69
<TS Page D-24
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1245 B
105 58 12 VS2 0.99
<TS 1246 B
105 58 25 VS2
-0.82
<TS 1247 B
105 58 22 VS6 0.88
<TS 1248 B
105 58 20 VS4 0.11
<TS 1249 B
105 58 19 VS4
-0.64
<TS 1250 B
105 68 15 VS2 0.14
<TS 1251 B
105 76 19 VS2 1
<TS 1252 B
105 78 14 VS2
-0.18
<TS 1253 B
105 78 15 VS2 1
<TS 1254 B
105 78 27 VS6
-0.73
<TS 1255 B
105 78 29 VS6 0.99
<TS 1256 B
105 80 24 VS2
-0.21
<TS 1257 B
105 88 13 VS2
-0.88
<TS 1258 B
105 88 14 07C
-0.96
<TS 1259 B
105 90 14 VS2 0.96
<TS 1260 B
105 90 14 VS4 1.18
<TS 1261 B
105 90 15 07C 0.81
<TS 1262 B
105 90 15 03C 0.39
<TS 1263 B
105 96 15 04C
-1.02
<TS 1264 B
105 110 24 DBH 0.66
<TS 1265 B
105 118 15 DBH 1.86
<TS 1266 B
105 120 17 03H
-0.83
<TS 1267 B
105 130 16 VS2
-0.63
<TS 1268 B
105 130 12 VS2 0.26
<TS 1269 B
105 130 23 03C 0.83
<TS 1270 B
105 134 19 02C 0.74
<TS 1271 B
105 136 15 VS4
-0.82
<TS 1272 B
105 136 17 01H 0.93
<TS 1273 B
106 31 14 VS4 0.37
<TS 1274 B
106 31 24 VS4 0.96
<TS 1275 B
106 31 17 03C 0.81
<TS 1276 B
106 35 17 03H 0.93
<TS 1277 B
106 35 21 04H 0.87
<TS 1278 B
106 35 16 03C 0.81
<TS 1279 B
106 35 17 02C
-0.15
<TS 1280 B
106 37 22 VS2
-0.54
<TS 1281 B
106 39 20 VS2
-0.69
<TS 1282 B
106 39 20 03C 0.79
<TS 1283 B
106 49 12 04H
-0.04
<TS 1284 B
106 51 9
VS2 1.08
<TS 1285 B
106 51 15 07C 0.65
<TS 1286 B
106 57 22 VS2 1.07
<TS 1287 B
106 63 14 VS4
-0.75
<TS 1288 B
106 63 23 VS2 0.18
<TS 1289 B
106 71 14 VS2
-0.23
<TS 1290 B
106 75 17 VS2 1.1
<TS 1291 B
106 77 23 VS2 1
<TS 1292 B
106 101 11 VS2
-0.36
<TS 1293 B
106 101 17 VS2
-0.83
<TS 1294 B
106 113 16 VS2
-0.13
<TS 1295 B
106 129 17 04C 0.78
<TS 1296 B
106 131 15 03C
-0.24
<TS Page D-25
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1297 B
107 32 16 VS4
-0.61
<TS 1298 B
107 34 13 VS6
-0.69
<TS 1299 B
107 36 19 VS2 0.8
<TS 1300 B
107 40 20 VS2 0.97
<TS 1301 B
107 42 31 VS2
-0.87
<TS 1302 B
107 42 33 VS2 0.85
<TS 1303 B
107 42 30 VS4 0.8
<TS 1304 B
107 42 20 VS4 0.24
<TS 1305 B
107 42 16 VS6
-0.89
<TS 1306 B
107 42 10 VS6 0.91
<TS 1307 B
107 44 16 06C
-0.26
<TS 1308 B
107 46 18 VS6
-0.72
<TS 1309 B
107 46 8
VS6 1
<TS 1310 B
107 52 15 VS6
-0.58
<TS 1311 B
107 52 14 07C 0.89
<TS 1312 B
107 58 16 DBH 1.84
<TS 1313 B
107 78 16 VS2
-0.87
<TS 1314 B
107 78 22 VS2 0.91
<TS 1315 B
107 82 34 VS2
-0.95
<TS 1316 B
107 82 30 VS2 0.86
<TS 1317 B
107 82 14 VS4 0.14
<TS 1318 B
107 96 26 VS2 0.88
<TS 1319 B
107 96 15 VS4 0.15
<TS 1320 B
107 114 14 VS2 0.34
<TS 1321 B
107 116 29 VS2 0.73
<TS 1322 B
107 116 32 VS2 0.06
<TS 1323 B
107 116 29 VS2
-0.79
<TS 1324 B
107 120 16 DBC 1.61
<TS 1325 B
107 124 18 04C 0.74
<TS 1326 B
107 130 21 03H 0.86
<TS 1327 B
107 132 17 07C 0.75
<TS 1328 B
107 132 18 04C 0.76
<TS 1329 B
107 132 32 03C 0.76
<TS 1330 B
107 132 19 02C 0.8
<TS 1331 B
108 33 30 VS4 0.89
<TS 1332 B
108 33 12 DBH
-0.92
<TS 1333 B
108 33 24 08H 0.62
<TS 1334 B
108 37 11 04C
-1.01
<TS 1335 B
108 37 23 03C
-0.37
<TS 1336 B
108 37 12 02C 0.69
<TS 1337 B
108 43 18 VS4
-0.88
<TS 1338 B
108 45 17 07C 0.8
<TS 1339 B
108 47 23 VS2
-0.54
<TS 1340 B
108 49 10 05H 0.96
<TS 1341 B
108 51 27 VS2
-0.54
<TS 1342 B
108 51 14 VS2 0.99
<TS 1343 B
108 59 21 VS2 0.86
<TS 1344 B
108 59 23 VS2
-0.82
<TS 1345 B
108 69 13 05H 0.95
<TS 1346 B
108 113 28 VS4 0.99
<TS 1347 B
108 113 29 VS4
-0.79
<TS 1348 B
108 115 18 07C 0.75
<TS Page D-26
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1349 B
108 129 12 04H
-0.04
<TS 1350 B
108 131 14 03C 0
<TS 1351 B
108 131 18 02C 0.95
<TS 1352 B
108 133 20 02C 0
<TS 1353 B
109 34 20 VS4
-0.67
<TS 1354 B
109 34 19 04C 0
<TS 1355 B
109 40 17 VS2
-0.76
<TS 1356 B
109 40 17 VS2 1.04
<TS 1357 B
109 40 20 VS4 0.04
<TS 1358 B
109 48 14 VS4
-0.82
<TS 1359 B
109 52 13 VS6 0.96
<TS 1360 B
109 52 37 VS2 0.9
<TS 1361 B
109 52 19 VS2
-0.88
<TS 1362 B
109 62 21 07C 0.73
<TS 1363 B
109 64 14 08C
-0.87
<TS 1364 B
109 78 18 04C
-0.97
<TS 1365 B
109 84 13 04H
-0.09
<TS 1366 B
109 96 14 VS2
-0.88
<TS 1367 B
109 104 24 VS2 0.98
<TS 1368 B
109 112 20 07H 0.92
<TS 1369 B
109 112 17 VS2
-0.54
<TS 1370 B
109 112 19 07C 0.82
<TS 1371 B
109 114 29 VS6
-1.16
<TS 1372 B
109 114 37 VS4
-0.93
<TS 1373 B
109 114 28 VS2
-0.13
<TS 1374 B
109 114 13 VS2
-0.73
<TS 1375 B
109 114 19 VS2 0.02
<TS 1376 B
109 120 15 04C
-0.97
<TS 1377 B
109 126 23 04H 0.88
<TS 1378 B
109 130 12 04C 0.65
<TS 1379 B
109 130 16 03C 0.93
<TS 1380 B
109 130 26 02C 0.72
<TS 1381 B
109 132 20 05C 0.85
<TS 1382 B
109 132 25 04C
-0.13
<TS 1383 B
110 37 19 04C
-0.94
<TS 1384 B
110 37 12 03C
-0.96
<TS 1385 B
110 41 11 02C 0.09
<TS 1386 B
110 51 11 05H 0.87
<TS 1387 B
110 55 14 VS2 0.9
<TS 1388 B
110 55 32 VS2
-0.86
<TS 1389 B
110 79 24 VS2 0.02
<TS 1390 B
110 97 20 08H 1.58
<TS 1391 B
110 97 18 VS2
-0.7
<TS 1392 B
110 131 16 02C 0.78
<TS 1393 B
110 131 18 02C
-0.97
<TS 1394 B
110 131 29 03C 0.83
<TS 1395 B
110 131 13 03C
-0.93
<TS 1396 B
111 40 14 DBC
-1.74
<TS 1397 B
111 50 22 VS2 0.77
<TS 1398 B
111 56 17 08H 0.15
<TS 1399 B
111 66 17 07H 0.95
<TS 1400 B
111 84 12 04H
-0.81
<TS Page D-27
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1401 B
111 122 15 03C
-1.02
<TS 1402 B
111 122 14 03C
-0.22
<TS 1403 B
111 128 15 03H
-0.81
<TS 1404 B
111 130 18 02H 0.17
<TS 1405 B
111 130 24 VS4 0.96
<TS 1406 B
112 37 32 04C
-0.99
<TS 1407 B
112 39 12 02H 0.93
<TS 1408 B
112 43 20 VS2
-0.8
<TS 1409 B
112 43 16 VS2 1.03
<TS 1410 B
112 43 15 VS4
-0.69
<TS 1411 B
112 45 12 03H 0.9
<TS 1412 B
112 45 15 VS2
-0.77
<TS 1413 B
112 47 28 VS2
-0.78
<TS 1414 B
112 47 15 VS2 1.06
<TS 1415 B
112 47 24 VS4 1.03
<TS 1416 B
112 53 18 VS2
-0.84
<TS 1417 8
112 53 17 VS2 0.88
<TS 1418 B
112 59 14 VS2 0.84
<TS 1419 8
112 59 15 VS2 0.24
<TS 1420 B
112 71 15.
VS2
-0.75
<TS 1421 B
112 79 13 04H
-0.73
<TS 1422 B
112 79 22 VS2 0.64
<TS 1423 8
112 121 16 02C 0.82
<TS 1424 8
112 127 27 03C 0.09
<TS 1425 8
113 36 14 VS2
-0.43
<TS 1426 8
113 36 12 VS2 0.95
<TS 1427 B
113 36 16 VS6
-0.86
<TS 1428 B
113 36 12 02C 0.77
<TS 1429 B
113 38 16 VS4
-0.69
<TS 1430 B
113 40 12 04H
-0.09
<TS 1431 B
113 40 14 VS4
-0.86
<TS 1432 B
113 40 16 03C
-0.61
<TS 1433 B
113 42 11 05H
-0.09
<TS 1434 B
113 42 17 VS4 0.97
<TS 1435 8
113 42 12 03C
-0.28
<TS 1436 B
113 44 14 01H 0.93
<TS 1437 8
113 66 10 06H 1.03
<TS 1438 8
113 70 20 07C 0.77
<TS 1439 8
113 70 19 07C 0
<TS 1440 B
113 84 14 02H
-0.83
<TS 1441 8
113 84 10 04H
-0.77
<TS 1442 B
113 110 15 04C 0.72
<TS 1443 B
113 130 22 VS4
-0.77
<TS 1444 8
114 37 25 DBH 1.3
<TS 1445 B
114 37 13 VS4
-0.6
<TS 1446 B
114 37 25 VS4 0.99
<TS 1447 B
114 37 12 04C 0.85
<TS 1448 B
114 37 19 VS2
-0.69
<TS 1449 B
114 37 26 VS2 0
<TS 1450 B
114 39 23 VS2
-0.71
<TS 1451 B
114 39 34 VS4 0.84
<TS 1452 B
114 39 12 02C 0.78
<TS Page D-28
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1453 B
114 127 15 05C 0.78
<TS 1454 B
114 127 25 03C 0.8
<TS 1455 B
114 129 15 VS4
-0.73
<TS 1456 B
115 38 11 02C 0.82
<TS 1457 B
115 38 11 VS4
-0.65
<TS 1458 B
115 38 31 01C 0
<TS 1459 B
115 68 11 05H 0.93
<TS 1460 B
115 84 19 03H
-0.81
<TS 1461 B
115 86 21 03H 0.86
<TS 1462 B
115 122 13 07H 0.93
<TS 1463 B
115 124 20 05C
-0.89
<TS 1464 B
115 126 19 03C 0.95
<TS 1465 B
115 126 15 03C
-0.91
<TS 1466 B
116 43 18 VS4 0.82
<TS 1467 B
116 45 15 06H 0.93
<TS 1468 B
116 45 16 VS2 0.02
<TS 1469 B
116 45 18 VS4 0.93
<TS 1470 B
116 47 16 VS4 0.86
<TS 1471 B
116 55 13 VS2
-0.88
<TS 1472 B
116 55 17 VS4 0.81
<TS 1473 B
116 77 16 VS2 0.59
<TS 1474 B
116 77 12 07C 0.74
<TS 1475 B
116 81 18 VS7
-0.89
<TS 1476 B
116 81 9
07C
-0.19
<TS 1477 B
116 81 16 07C
-0.93
<TS 1478 B
116 97 10 04C
-0.26
<TS 1479 B
116 103 15 05C 0.83
<TS 1480 B
116 111 15 05H
-0.86
<TS 1481 B
116 111 19 04C
-1
<TS 1482 B
116 115 23 VS4 0.84
<TS 1483 B
116 117 15 03C
-0.98
<TS 1484 B
116 117 19 03C
-0.22
<TS 1485 B
116 125 17 05C 0.79
<TS 1486 B
116 125 16 04C 0
<TS 1487 B
116 125 19 04C 0.78
<TS 1488 B
116 125 39 03C 0.72
<TS 1489 B
117 40 8
05C 0.77
<TS 1490 B
117 40 18 04C
-0.22
<TS 1491 B
117 40 19 03C
-0.93
<TS 1492 B
117 40 13 02C 0.72
<TS 1493 B
117 40 9
01C
-0.94
<TS 1494 B
117 40 20 02C
-0.86
<TS 1495 B
117 40 11 02C
-0.24
<TS 1496 B
117 44 9
02C 0.74
<TS 1497 B
117 48 10 03C
-1
<TS 1498 B
117 66 13 07C 0.9
<TS 1499 B
117 66 11 06H 1
<TS 1500 B
117 68 18 05H 0.94
<TS 1501 B
117 82 11 06H
-0.76
<TS.
1502 B
117 90 14 08C 0.86
<TS 1503 B
117 112 21 04H 1.03
<TS 1504 B
118 41 10 03C
-0.24
<TS Page D-29
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1505 B
118 41 9
02H 0.92
<TS 1506 B
118 43 17 VS6 0
<TS 1507 B
118 43 15 VS4 0.99
<TS 1508 B
118 73 15 VS6
-0.85
<TS 1509 B
118 73 16 VS?
-0.75
<TS 1510 B
118 87 14 VS2 1.03
<TS 1511 B
118 89 26 VS2 0.96
<TS 1512 B
118 89 16 VS4 0.66
<TS 1513 B
118 97 15 VS2
-0.77
<TS 1514 B
118 101 13 08C 0.79
<TS 1515 B
118 105 20 VS4
-0.62
<TS 1516 B
118 117 17 04C
-0.17
<TS 1517 B
118 123 21 04C
-0.95
<TS 1518 B
118 123 14 02C 0.8
<TS 1519 B
119 42 16 03C 0.35
<TS 1520 B
119 42 21 04C
-0.63
<TS 1521 B
119 42 10 02H 0.9
<TS 1522 B
119 42 16 VS?
-0.74
<TS 1523 B
119 44 18 02H 0.9
<TS 1524 B
119 44 15 01C 0.7
<TS 1525 B
119 46 17 02C 0.78
<TS 1526 B
119 72 20 DBC 1.09
<TS 1527 B
119 88 21 08C 0.82
<TS 1528 B
119 88 9
08C
-0.24
<TS 1529 B
119 104 17 VS1
-0.66
<TS 1530 B
119 112 11 03C
-0.89
<TS 1531 B
119 112 19 03C 0.84
<TS 1532 B
119 112 20 04C 0.78
<TS 1533 B
120 43 16 01C
-0.92
<TS 1534 B
120 45 13 02C 0.8
<TS 1535 B
120 47 22 03C 0.77
<TS 1536 B
120 47 8
03C
-1.02
<TS 1537 B
120 49 10 03C
-0.92
<TS 1538 B
120 61 18 08C 0.78
<TS 1539 B
120 103 14 07H 0.89
<TS 1540 B
120 105 19 VS2
-0.73
<TS 1541.
B 120 113 20 VS2 0.9
<TS 1542 B
120 113 26 VS2
-0.84
<TS 1543 B
120 115 26 03C 0.76
<TS 1544 B
121 44 15 01H 0.9
<TS 1545 B
121 114 18 VS4
-0.88
<TS 1546 B
121 118 21 02C 0.78
<TS 1547 B
121 122 14 02H 0.86
<TS 1548 B
122 71 13 05H 0.93
<TS 1549 B
122 71 14 VS2
-0.71
<TS 1550 B
123 52 17 02C 0.7
<TS 1551 B
123 72 13 VS4
-0.77
<TS 1552 B
123 72 13 VS?
0.77
<TS 1553 B
123 116 39 VS6
-0.45
<TS 1554 B
123 116 16 05C
-0.96
<TS 1555 B
123 116 11 04C 0.76
<TS 1556 B
123 116 11 03C 0.8
<TS Page D-30
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1557 B
123 118 36 VS6
-0.69
<TS 1558 B
123 118 20 VS7
-0.9
<TS 1559 B
124 47 12 03C 0.74
<TS 1560 B
124 47 12 01C
-0.22
<TS 1561 B
124 49 15 02C
-1.07
<TS 1562 B
124 51 17 VS4 0.65
<TS 1563 B
124 55 13 05H
-0.11
<TS 1564 B
124 57 17 VS7
-0.86
<TS 1565 B
124 73 11 VS2 0.78
<TS 1566 B
124 85 13 VS2 0.19
<TS 1567 B
124 85 9
VS2 0.71
<TS 1568 B
124 85 12 VS4
-0.39
<TS 1569 B
124 87 17 VS4 0.9
<TS 1570 B
124 93 15 VS2
-0.69
<TS 1571 B
124 93 26 VS2 0.06
<TS 1572 B
124 93 11 VS2 0.79
<TS 1573 B
124 95 18 VS2 0
<TS 1574 B
124 95 21 VS4
-0.82
<TS 1575 B
124 95 22 VS4 1.08
<TS 1576 B
124 97 13 06C 0.91
<TS 1577 B
124 105 13 06C 0.7
<TS 1578 B
124 117 24 04C 0.74
<TS 1579 B
124 117 10 06C
-0.92
<TS 1580 B
124 117 14 06C 0.78
<TS 1581 B
124 117 25 VS7
-0.17
<TS 1582 B
124 117 14 VS4 0.71
<TS 1583 B
124 119 15 08C
-0.15
<TS 1584 B
124 119 17 08C 0.81
<TS 1585 B
125 48 14 VS4 0.85
<TS 1586 B
125 48 15 VS6 0.87
<TS 1587 B
125 78 14 03H
-0.79
<TS 1588 B
125 82 14 05H
-0.91
<TS 1589 B
125 94 18 VS2
-0.65
<TS 1590 B
125 94 14 VS2
-0.17
<TS 1591 B
125 100 12 08C 0.76
<TS 1592 B
125 104 17 07H 0.86
<TS 1593 B
125 104 22 07C
-0.26
<TS 1594 B
125 112 23 02C 0.66
<TS 1595 B
125 114 15 03C 0.76
<TS 1596 B
125 116 19 VS4
-0.84
<TS 1597 B
126 55 16 02C 0.78
<TS 1598 B
126 55 14 06H 0.96
<TS 1599 B
126 61 14 VS1 0.89
<TS 1600 B
126 81 11 VS4
-0.75
<TS 1601 B
126 83 20 VS1
-0.21
<TS 1602 B
126 91 20 VS2 0
<TS 1603 B
126 91 12 VS4
-0.8
<TS 1604 B
126 95 18 VS4
-0.82
<TS 1605 B
126 95 18 VS6 1.1
<TS 1606 B
126 99 14 08C 0.76
<TS 1607 B
126 99 14 07C 0.74
<TS 1608 B
126 103 19 VS4 0.9
<TS Page D-31
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1609 B
126 115 21 02C 0.8
<TS 1610 B
126 115 11 02C 0.07
<TS 1611 B
127 52 10 01H
-0.09
<TS 1612 B
127 54 23 01H
-0.78
<TS 1613 B
127 72 12 05H 0.87
<TS 1614 B
127 92 12 VS6
-0.8
<TS 1615 B
127 92 21 08C
-0.22
<TS 1616 B
127 102 17 07C
-0.28
<TS 1617 B
127 104 14 06C 0.78
<TS 1618 B
127 106 20 07C
-0.22
<TS 1619 B
127 112 14 02C 0.74
<TS 1620 B
127 114 19 01H
-0.83
<TS 1621 B
127 114 17 02C 0.76
<TS 1622 B
127 114 15 03C 0.78
<TS 1623 B
128 53 16 01H
-0.11
<TS 1624 B
128 55 22 01C
-0.59
<TS 1625 B
128 73 11 06H 0.11
<TS 1626 B
128 73 15 06H 0.94
<TS 1627 B
128 73 25 VS1 0.16
<TS 1628 B
128 73 16 VS4 1.01
<TS 1629 B
128 99 15 07C 0.76
<TS 1630 B
128 101 23 05C 0.73
<TS 1631 B
128 113 26 02C
-1
<TS 1632 B
129 56 20 01H 0.92
<TS 1633 B
129 58 13 01H
-0.69
<TS 1634 B
129 64 10 VS?
-0.78
<TS 1635 B
129 68 13 02H
-0.82
<TS 1636 B
129 84 20 06H 0.88
<TS 1637 B
129 102 10 08C 0
<TS 1638 B
129 102 22 08C
-0.98
<TS 1639 B
129 104 15 07C
-0.22
<TS 1640 B
129 106 21 08C 0.84
<TS 1641 B
129 110 19 02C 0.74
<TS 1642 B
130 55 23 01H 0.94
<TS 1643 B
130 55 18 02C 0.76
<TS 1644 B
130 65 11 VS2
-0.14
<TS 1645 B
130 65 17 VS4 0.69
<TS 1646 B
130 65 28 VS?
0.99
<TS 1647 B
130 69 12 05H 0.91
<TS 1648 B
130 79 13 VS2
-0.85
<TS 1649 B
130 91 23 DBC 1.63
<TS 1650 B
131 58 32 01C 0.7
<TS 1651 B
131 60 18 VS6 0.8
<TS 1652 B
131 64 29 VS?
0.99
<TS 1653 B
131 70 14 03C 0.78
<TS 1654 B
131 78 16 VS6
-0.79
<TS 1655 B
131 82 19 08H
-0.82
<TS 1656 B
131 96 20 04C 0.73
<TS 1657 B
131 98 32 VS6 0.97
<TS 1658 B
131 98 13 DBC 1.62
<TS 1659 B
131 98 31 VS?
0.58
<TS 1660 B
131 102 23 06C
-1.02
<TS Page D-32
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1661 B
131 102 19 05C 0.7
<TS 1662 B
131 102 14 04C 0.76
<TS 1663 B
131 104 31 VS7 0.94
<TS 1664 B
131 104 20 DBC 1.78
<TS 1665 B
131 108 14 07H
-0.94
<TS 1666 B
132 61 12 01H 0.98
<TS 1667 B
132 75 12 02H 0.87
<TS 1668 B
132 81 16 05H 0.92
<TS 1669 B
132 91 14 DBC 1.66
<TS 1670 B
132 97 9
VS1 0.93
<TS 1671 B
132 97 17 VS2
-0.67
<TS 1672 B
132 97 12 VS4
-0.95
<TS 1673 B
132 97 22 VS7 0.99
<TS 1674 B
132 101 18 06C 0.74
<TS 1675 B
132 101 15 06C
-0.2
<TS 1676 B
132 107 26 02C
-1.03
<TS 1677 B
133 68 15 02H 0.93
<TS 1678 B
133 74 15 03H 0.85
<TS 1679 B
133 76 16 07C 0.86
<TS 1680 B
133 100.
25 VS7 0
<TS 1681 B
133 102 14 VS7
-0.74
<TS 1682 B
133 102 16 07C
-1.04
<TS 1683 B
133 104 16 VS7 0.97
<TS 1684 B
133 104 11 DBC 1.64
<TS 1685 B
134 63 19 DBH
-1.79.
<TS 1686 B
134 63 15 07C 0.74
<TS 1687 B
134 65 11 VS2
-0.67
<TS 1688 B
134 65 20 02H 0.84
<TS 1689 B
134 69 26 VS7 0.96
<TS 1690 B
134 69 18 04H 0.94
<TS 1691 B
134 95 18 DBC 1.66
<TS 1692 B
134 97 15 VS6
-0.86
<TS 1693 B
134 97 18 VS6 0.86
<TS 1694 B
134 99 11 VS4
-0.87
<TS 1695 B
134 99 12 VS6
-0.89
<TS 1696 B
134 99 23 VS6 0.93
<TS 1697 B
134 101 24 VS7 0.99
<TS 1698 B
135 68 20 VS7 0.85
<TS 1699 B
135 72 19 VS7
-0.87
<TS 1700 B
135 76 13 06H 0.87
<TS 1701 B
135 76 18 VS7
-0.79
<TS 1702 B
135 76 18 08C 0.79
<TS 1703 B
135 76 20 08C
-1.02
<TS 1704 B
135 80 17 07H
-0.86
<TS 1705 B
135 82 24 VS7
-0.8
<TS 1706 B
135 82 29 VS7 0.94
<TS 1707 B
135 90 31 VS7 0.6
<TS 1708 B
135 92 27 07C O.S5
<TS 1709 B
135 92 36 08C 1.01
<TS 1710 B
135 92 38 VS7
-0.66
<TS 1711 B
135 94 27 DBC 1.75
<TS 1712 B
135 96 11 04C 0.76
<TS Page D-33
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1713 8
135 98 12 VS6
-0.73
<TS 1714 8
136 69 19 DBC 1.88
<TS 1715 B
136 77 17 03H 0.89
<TS 1716 B
136 87 16 08C
-1.11
<TS 1717 B
136 91 20 DBC 1.86
<TS 1718 B
136 95 20 03C 0.72
<TS 1719 B
136 97 30 VS?
-0.73
<TS 1720 B
136 97 16 VS?
0.95
<TS 1721 B
136 97 14 08C
-0.04
<TS 1722 B
136 97 18 08C
-1.05
<TS 1723 8
136 97 14 07C 0.75
<TS 1724 8
136 97 17 03C 0.85
<TS 1725 8
137 74 16 06H 0.78
<TS 1726 8
137 76 14 05H 0.88
<TS 1727 B
137 78 12 03H
-0.73
<TS 1728 B
137 80 20 08H 0.86
<TS 1729 B
137 90 22 DBH 1.79
<TS 1730 B
137 90 12 VS1
-0.82
<TS 1731 B
137 90 16 VS4 0.24
<TS 1732 B
137 90 15 VS4 0.86
<TS 1733 B
137 90 15 VS6
-0.52
<TS 1734 8
137 90 22 VS?
-0.82
<TS 1735 8
137 90 18 VS?
0.93
<TS 1736 B
137 90 16 DBC 1.81
<TS 1737 8
137 92 22 VS?
-0.58
<TS 1738 8
137 92 19 08C
-1.05
<TS 1739 8
137 92 17 07C 0.04
<TS 1740 B
138 75 9
08H
-0.14
<TS 1741 B
138 77 19 02H 0.93
<TS 1742 8
138 77 12 03H
-0.82
<TS 1743 B
138 77 22 VS4 0.77
<TS 1744 B
138 79 16 03H 0.92
<TS 1745 B
138 79 30 VS1
-0.67
<TS 1746 B
138 79 24 VS2 0.74
<TS 1747 B
138 79 21 VS4 0.88
<TS 1748 B
138 79 21 VS6
-0.86
<TS 1749 B
138 79 22 VS6 0.88
<TS 1750 B
138 81 22 VS4
-0.86
<TS 1751 B
138 81 15 08C
-1.12
<TS 1752 B
138 85 15 08H 0.8
<TS 1753 B
138 85 28 DBH 1.9
<TS 1754 B
138 87 20 VS1
-0.82
<TS 1755 B
138 87 14 VS1 0.97
<TS 1756 B
138 87 18 VS4
-0.62
<TS 1757 B
138 89 19 VS4
-0.58
<TS 1758 B
138 89 15 VS6 0.8
<TS 1759 B
138 89 18 VS?
-0.82
<TS 1760 B
138 89 30 VS?
0.86
<TS 1761 B
138 89 15 O?C 0.72
<TS 1762 B
138 91 18 DBH 1.94
<TS Page D-34
ATTACHMENT Palisades Nuclear Plant Steam Generator Tube Inspection Report 2015 Refueling Outage, 1 R24 AREVA Inc. Document Number 51 ~9252894-001 92 pages follow
A 20004-021 (01/30/2014)
AREVA AREVA Inc.
Engineering Information Record Document No.:
51 9252894 -
001
~~~~~~~~~-
Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Page 1of92
A AREVA 20004-021 (01/30/2014)
Document No.: 51-9252894-001 Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Safety Related?
[ZJYES ONO Does this document establish design or technical requirements?
DYES
[ZJ NO Does this document contain assumptions requiring verification?
DYES
[ZJ NO Does this document contain Customer Required Format?
~YES D NO Signature BIQck Pages/Sections Nameand Title/Discipline P/LP, R/LR, Prepared/Reviewed/
Signature A-CRF, A Date Approved or Comments Kent Colgan Advisory Engineer Craig Kelley Supervisory Engineer Paul Ulmer Project Manager James Campbell Manager p
R A-CRF Note: P/LP designates Preparer (P), Lead Preparer (LP)
R/LR designates Reviewer (R), Lead Reviewer (LR) o3/ fl,/p;lt All All 3/1(;./ l-f,
/t64bl{,
All 3/&/tt All A-CRF designates Project Manager Approver of Customer Required Format (A-CRF)
A designates Approver/RTM - Verification of Reviewer Independence Project Manager Approval of Customer References (N/A if not applicable)
Name Title (printed or typed)
{printed or typed)
Signature N/A N/A N/A Date N/A Page2
A AREVA Revision No.
000 001 20004-021 (01 /30/2014)
Document No.: 51-9252894-001 Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Record of Revision Pages/Sections/
Paragraphs Changed Brief Description I Change Authorization N/A Original release Page3 Updated record of revision Page 10 Corrected Table 3 title Page 3
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table of Contents Page SIGNATURE BLOCK............................................................................................................................. 2 RECORD OF REVISION....................................................................................................................... 3 LIST OF TABLES.................................................................................................................................. 5 LIST OF FIGURES................................................................................................................................ 6 1.0 PURPOSE................................................................................................................................. 7 2.0 ASSUMPTIONS......................................................................................................................... 7 3.0 INPUTS...................................................................................................................................... 7 4.0 180-DA Y REPORT..................................................................................................................... 7
5.0 CONCLUSION
......................................................................................................................... 18
6.0 REFERENCES
......................................................................................................................... 18 APPENDIX A:* ACRONYMS AND ABBREVIATIONS....................................................................... A-1 APPENDIX B: STEAM GENERATOR LAYOUT AND NOMENCLATURE......................................... B-1 APPENDIX C: SUPPORT WEAR LISTING - SGA........................................................................... C-1 APPENDIX D : SUPPORT WEAR LISTING - SGB........................................................................... D-1 Page4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 List of Tables Page Table 1: Refueling Outage (RFO) Information since SG Replacement.................................................. 8 Table 2: Eddy Current Tube Inspection Scope...................................................................................... 9 Table 3: Active Degradation Mechanisms........................................................................................... 10 Table 4: Eddy Current Techniques Utilized......................................................................................... 1 O Table 5: Axial ODSCC Indications...................................................................................................... 13 Table 6: Circumferential ODSCC Indication........................................................................................ 14 Table 7: Historical Foreign Object Wear Indications (Volumetric) - No Object Present........................ 14 Table 8: New Foreign Object Wear Indications (Volumetric) - Object Present.................................... 14 Table 9: Diagonal Bar Wear Summary................................................................................................ 14 Table 1 O: Vertical Strap Wear Summary............................................................................................. 15 Table 11: Egg crate Wear Summary.................................................................................................... 15 Table 12: Tubes Affected by Support Wear........................................................................................ 15 Table 13: Number of Tubes Plugged.................................................................................................. 16 Table 14: Specific Tubes Plugged...................................................................................................... 17 Table 15: Overall Plugging Summary.................................................................................................. 17 Table 8-1: Palisades SG Tube Support Structure Nomenclature....................................................... 8-2 Page 5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 List of Figures Page Figure 8-1: General Layout of Palisades SG Tube Support Structures.............................................. 8-1 Figure 8-2: Palisades SG Tubesheet Map......................................................................................... 8-2 Page6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1.0 PURPOSE The purpose of this document is to provide the 1 R24 steam generator (SG) tube inspection report in accordance with Palisades Technical Specification 5.6.8, "Steam Generator Tube Inspection Reports."
The report is provided in its entirety in Section 4.0 and the appendices of this document, from which it may be copied and modified as necessary by the Palisades Licensing Department.
2.0 ASSUMPTIONS No assumptions were used in the preparation of this document.
3.0 INPUTS The information summarized in this report was extracted from References [1] and [2].
4.0 180-DAY REPORT Introduction Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports, requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report is required to address the following items:
- a. The scope of inspections performed on each SG
- b. Active degradation mechanisms found
- c. Nondestructive examination techniques utilized for each degradation mechanism
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications
- e. Number of tubes plugged during the inspection outage for each active degradation mechanism
- f.
Total number and percentage of tubes plugged to date
- g. The results of condition monitoring, including the results of tube pulls and in-situ testing
- h. The effective plugging percentage for all plugging in each SG.
Entergy and AREVA performed a SG inspection in accordance with TS 5.5.8 during the Palisades fall
- 2015 refueling outage (1R24). This inspection was the 16th in-service inspection following SG replacement and the 3rd of 3 scheduled inspections in the fourth sequential Inspection period. Initial entry into mode 4 occurred on October 17, 2015; therefore, this report is required to be submitted by April 14, 2016.
The following section ("Background") briefly describes the Palisades SG design characteristics and operating history, while the subsequent section ("Specific Responses") provides responses to each of the TS 5.6.8 questions. Appendix A provides definitions for the acronyms and abbreviations used in this report.
Page7
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24
Background
Palisades is a Combustion Engineering (CE) PWR equipped with two CE Model 2530 replacement steam generators. These steam generators were installed in the early 1990's as replacements for the original steam generators. Each steam generator contains 8219 lnconel 600 tubes with an outer diameter of 0.75 inches and nominal wall thickness of 0.042 inches. The tubes are arranged in a 1-inch triangular-pitch pattern comprised of 138 rows and 165 columns. The tubes in rows 1 through 18 are of u-bend design with a minimum bend radius of 2.5 inches (row 1) and maximum radius of 11 inches (row 18). The tubes in Rows 19 through 138 are of "square-bend" design consisting of two 90 degree bends of constant radius with a straight horizontal section of tubing of varying length between the two bends. The tubes were explosively expanded throughout the full tubesheet depth and are supported by several structures which include horizontal eggcrate supports, diagonal bars, and vertical strap supports. All of the support structures were fabricated with stainless steel. The general layout of the steam generator internals and associated nomenclature are provided in Appendix B.
The Palisades SGs had accrued 19. 73 effective full power years (EFPY) of operation through the end of cycle 24 (i.e., 1 R24) with a nominal hot leg temperature of 583°F. The 1 R24 inspection of the two Palisades SGs was the 161h in-service inspection (ISi) following SG installation in 1990, and the last of three scheduled inspections in the fourth sequential inspection period (Table 1).
Table 1: Refueling Outage (RFO) Information since SG Replacement Outage Cycle Outage Year EFPD 1R9 1992 298.5 1R10 1993 356.8 1R11 1995 430.5 1R12 1996 407.4 1R13 1998 419.6 1R14 1999 449.3 1R15 2001 401.3 1R16 2003 444.3 1R17 2004 493.1 1R18 2006 487.9 1R19 2007 459.3 1R20 2009 499.8 1R21 2010 507.7 1R22 2012 504.0 1R23 2014 513.3 1R24 2015 539.5 EFPD = effective full power days EFPM = effective full power months EFPY =effective full power years Cumulative EFPY 0.82 1.79 2.97 4.09 5.24 6.47 7.57 8.78 10.13 11.47 12.73 14.09 15.48 16.84 18.25 19.73 First Second Third Inspection Inspection Inspection Period Period Period (EFPMs)
(EFPMs)
(EFPMs) 9.84 11.72 25.87 39.25 53.04 7.80 20.98 35.58 51.78 7.81 22.90 39.32 56.00 Fourth Inspection Period (EFPMs) 12.54 29.14 46.86 Page 8
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Specific Responses This section provides responses to each of the requirements specified by TS 5.6.8. Bold wording represents TS verbiage. The required information is provided immediately following the restatement of each reporting requirement.
A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.8, Steam Generator (SG) Program. The report shall include:
- a.
The scope of inspections performed on each SG The 1 R24 work scope in both SGs (SGA and SGB) included eddy current (ECT) inspections, primary side visual inspections, and secondary side visual inspections. A summary of the ECT inspections performed is provided in Table 2.
Table 2: Eddy Current Tube Inspection Scope Scope Probe Type SGA SGB Full LengthCD Bobbin 100%
100%
Row 1 through 3 U-bends MRPC 100%
100%
Hot Leg Tubesheets TTS+3"/-13.5" MRPC 100%
100%
Cold Leg Outer Three Periphery Tubes TTS+3"/-2" for detection of possible loose MRPC 12.8%
12.7%
parts or wear signals<Il Freespan Dings >5.0 Volts between TSH MRPC and TSC 100%
100%
Dents >2.0 Volts at Vertical Straps, Diagonal MRPC Bars & Eggcrates between TSH and TSC 100%
100%
Wear at Eggcrates (Current and Historical)
MRPC 100%
100%
Historical Wear at Diagonal Bars and MRPC 25%
25%
Vertical Straps Supplemental MRPC 100%
100%
CD Except for the bend portion of rows 1 through 3 CV The values shown are percentages of the installed tube population All DOI, OSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications The primary side inspection scope included a visual examination of both legs of the primary channel heads of both SGs. This examination was performed in the as-found state (prior to any other SG inspections), and in the as-left state (after all other SG inspections were completed). The purpose of the examinations was to assess the general material condition, to assess the condition of all installed Page 9
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 tube plugs, to assess the integrity of the cladding, and to identify and remove any foreign objects present (none were identified). No anomalous conditions were identified during these inspections. All plugs were present in the proper location and no degradation was observed.
The secondary side work scope included a Foreign Object Search and Retrieval (FOSAR) inspection at the top-of-tubesheet (TIS) in the tube-to-shell annulus and divider lane in both SGs. All visually accessible passages between tubes were viewed from the tube bundle periphery on each leg.
- b.
Active degradation mechanisms found The degradation mechanisms identified during the 1 R24 SG examinations are described in Table 3. No new degradation mechanisms were identified.
Table 3: Active Degradation Mechanisms SG Location Damage Mechanism Both Diagonal Bar (DB) Support Wear Both Vertical Strap (VS) Support Wear Both Eggcrate (EC) Support Wear Both Adjacent to Foreign Object (FO)
Wear Both Hot Leg EC Supports Axial ODSCC Both Hot Leg Top-of-Tubesheet (TTS)
Axial ODSCC SGA Hot Leg Top-of-Tubesheet (TTS)
Circumferential ODSCC
- c.
Nondestructive examination techniques utilized for each degradation mechanism The nondestructive examination techniques utilized during 1 R24 for each potential and existing degradation mechanism are identified in Table 4. In all cases the utilized NOE techniques were based on the eddy current method.
Table 4: Eddy Current Techniques Utilized Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Bobbin Probe Tube to Tube Bobbin 13091.1 Freespan tube-to-tube None Yes Yes Wear Rev. 0 wear Freespan (excluding u-Axial ODSCC Bobbin 128413 bend), eggcrate, sludge None Yes No Rev. 3 pile, & broached TSPs with or without dents S2Vpp Axial ODSCC Bobbin 24013.1 Freespan including dings None Yes No Rev. 2 S5V Page 10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Foreign 27091.2 Foreign object wear Extended for Object Wear Bobbin Rev. 1 (part not present); 1-690 1-600 tubing Yes Yes tubing 96004.1 AVBs, TSPs, Support Wear Bobbin Rev. 13 vertical and diagonal Dents <5V Yes Yes straps Pitting Bobbin 96005.2 Freespan in the Sludge Pile Yes Yes Rev. 9 presence of copper Axial ODSCC 128424 Depth:
Rev. 3 Yes (detect);
TSP (with or without dents BED:
Axial ODSCC
+Point' None Yes 128431
<=2vpp) and sludge pile Yes Rev.,2 BEL:
(sizing)
Yes 128425 Depth:
Rev. 3 Yes (detect)
Freespan (excluding u-Axial ODSCC
+Point' bend), eggcrate, &
None Yes BED:
128432 broached TSPs with or Yes Rev.2 without dents ::;2Vpp (sizing)
BEL:
Yes Axial ODSCC
+Point' 10411.1 Low Row U-bends Higher Row Yes Depth:
Rev. 0 U-bends Yes PDA:
21409.1 Support structures, Info" Axial ODSCC
+Point' Rev. 7 freespan, sludge pile, &
U-bends Yes tubesheet crevice Length:
Info Freespan dings &
Depth:
Info Axial ODSCC
+Point' 22401.1 Dented TSPs dented eggcrates, Yes Rev. 4 diagonal bars and Length:
vertical straps Yes Axial PWSCC Depth:
Yes Axial PWSCC
+Point' 20511.1 Expansion Transitions Tubesheet Yes PDA:
Rev. 8 Info Length:
Yes Depth:
96703.1 Tubesheet, Yes Axial PWSCC
+Point' Dents/Dings Yes Rev. 17 Dented supports Length:
Yes Page 11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Axial PWSCC
+Point' 96511.2 Low Row U-bends Higher Row Yes Depth:
Rev. 16 U-bends Yes
+Point' 99997.2 Higher Row Depth:
Axial PWSCC High Low Row U-bends Yes Freq Rev. 10 U-bends Yes Circumferential ODSCC Depth:
21410.1 U-bends, Info Circ ODSCC
+Point' Rev. 6 Expansion Transitions freespan dings, Yes Note 4 dented supports PDA:
Yes Circ ODSCC
+Point' 22842.1 Dented Supports Freespan dings, Yes Length:
Rev.4 u-bends Yes Circumferential PWSCC 111524 U-bends, Circ PWSCC
+Point' Rev. 0 Expansion Transitions Dents/Dings, Yes No Tubesheet Depth:
Yes Circ PWSCC
+Point' 20510.1 Expansion Transitions U-bends No (see PDA:
Rev. 7 111524)
Yes Length:
Yes Circ PWSCC
+Point' 96511.2 See "Axial PWSCC" section of this table Rev. 16 Depth:
Yes Circ PWSCC
+Point' 96701.1 Expansion Transitions Dents/Dings and No (see PDA:
Rev. 12 tubesheet 111524)
Yes Length:
Yes
+Point' 99997.2 Circ PWSCC High Rev. 10 See "Axial PWSCC" section of this table Freq Wear Tube to Tube
+Point' 13901.1 Freespan tube-to-tube U-bends Yes Depth:
Wear Rev. 1 wear Yes Dented/non-10908.4 dented Supports, Depth:
Wear
+Point' Rev. 1 AVBs Foreign object Yes Yes wear (part present)
Foreign
+Point' 27901 Foreign object wear Volumetric or.115 through Freespan Wear Yes Yes Object Wear*
Pancake 27907 (part not present)
(part not present)
Pitting Page 12 J
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Degradation Probe EPRI Demonstrated Extended Mechanism Type ETSS Applicability Applicability Detection Sizing Pitting
+Point' 21998.1 Volumetric in freespan Sludge Pile Yes Depth:
Rev.4 Yes
- Multiple ETSSs are available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used.
- d.
Location, orientation (if linear), and measured sizes (if applicable) of service induced indications The location, orientation, and measured size of axial ODSCC, circumferential ODSCC, and foreign object wear indications identified during the 1 R24 outage are provided in Table 5, Table 6, Table 7, and Table 8. Due to the large number support wear indications, the required data is provided in Appendix C.
Statistical summaries of throughwall depth, growth rates of support wear populations (i.e., diagonal bar, vertical strap, and egg crate wear), and the number of tubes affected by support wear are provided in Table 9, Table 10, Table 11, and Table 12. In these tables, "New" refers to support wear indications that were newly reported during the 1 R24 outage, and "Repeat" refers to support wear indications reported during previous outage inspection(s) and again measured during 1 R24.
Table 5: Axial ODSCC Indications NOE
+Point 300 Maximum Structural kHz Depth Depth Amplitude
(%TW)
NOE Axial Structural
(%TW)
SG Row Col.
Location (Vpp)
(Note 1)
Length (in.)
Length (in.)
(Note 1)
A 11 110 02H-0.53" 0.35 46.0 0.80 0.3 34.4 A
37 118 TSH+0.65" 0.65 59.8 0.38 0.16 48.4 A
40 117 TSH+0.51" 0.64 59.5 0.67 0.32 49.2 A
75 86 TSH+1.22" 0.40 51.7 0.22 A
78 97 TSH+0.61" 0.39 51.3 0.25 A
83 88 TSH+0.41" 0.30 47.0 0.19 A
105 98 TSH+0.30" 0.83 63.8 0.22 0.16 55.0 B
35 116 TSH+0.85" 0.26 44.6 0.29 B
49 112 TSH+0.40" 0.39 51.3 0.29 B
72 93 02H-0.67" 0.32 44.2 0.56 B
75 94 TSH+1.25" 0.30 47.0 0.32 B
76 91 TSH+1.09" 0.54 56.7 0.29 0.16 50.6 Note 1) The NOE maximum depth values were calculated using the Appendix I regression techniques (%TW as function of NOE voltage) and then reduced by 11 %TW in accordance with the Entergy Appendix I deviation.
Both the NOE maximum depth and structural depth values, shown in this table, reflect the 11 % TW reduction.
Page 13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 6: Circumferential ODSCC Indication NOE Percent Degraded Area
+Point 300 kHz (PDA)
Circumferential SG Row Col Location Amplitude (Vpp)
(Note 1)
Length (deg.)
A 59 60 TSH+O.O" 0.83 6
58 Note 1) The percent degraded area (PDA) of the circumferential indication was determined using the EPRI Draw Program based on measurements from EPRI ETSS H-21410.1.
Table 7: Historical Foreign Object Wear Indications (Volumetric) - No Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (%TW)
Extent (0 )
Extent (in.)
A 130 63 TSH + 1.46 21998.1 20 29 0.45 8
137 92 TSH + 10.76 21998.1 22 31 0.33 8
137 92 TSH+11.85 21998.1 22 31 0.33 Table 8: New Foreign Object Wear Indications (Volumetric) - Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (%TW)
Extent (0 )
Extent (in.)
A 33 162 TSH + 13.23" 10908.4 14 29 0.27 A
127 110 TSH + 1.08" 10908.4 33 23 0.38 A
129 110 TSH + 0.57" 10908.4 15 31 0.32 Table 9: Diagonal Bar Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
5 139 13.9 26.0 35.0 0.2 2.7 8.1 B
5 105 "16.9 27.0 31.0 0.7 4.1 7.4 Both 10 244 15.2 27.0 35.0 0.4 3.4 8.1 SGs Page 14 J
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 10: Vertical Strap Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
3 668 17.0 31.0 39.0 0.1 2.7 8.1 B
3 704 19.2 32.0 39.0 0.4 3.4 10.2 Both 6
1372 18.1 32.0 39.0 0.3 3.4 10.2 SGs Table 11: Eggcrate Wear Summary Number of New and Repeat Depths Growth Rate of Repeats SG Indications
(%TW)
(%TW/EFPY)
Upper Upper New Repeat Average 95th Maximum Average 95th Maximum A
18 1064 14.1 22.0 34.0 0.2 2.7 5.4 B
8 937 15.3 22.8 39.0 0.3 2.7 5.4 Both 26 2001 14.7 22.0 39.0 0.2 2.7 5.4 SGs Table 12: Tubes Affected by Support Wear SG Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear A
139 402 825 B
106 441 769
- e.
Number of tubes plugged during the inspection outage for each active degradation mechanism The number of tubes plugged during the 1 R24 outage, categorized by degradation mechanism, is summarized in Table 13, while Table 14 identifies each tube that was plugged.
All of the tubes with ODSCC indications were plugged and the circumferential ODSCC indication was stabilized prior to plugging. None of the support wear indications exceeded the technical specification plugging limit of 40% TW; hence, none of the affected tubes required plugging.
Two foreign objects in SG A caused wear in three tubes (Table 8). The objects were not retrievable and consequently, the affected tubes were stabilized and plugged. Two additional tubes (SGA R31 C162, SGA R32 C161) adjacent to one of the objects, were preventively stabilized and plugged even though neither had experienced degradation. This was done to address the potential that the object could Page 15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 degrade these tubes in the future. Historical foreign object wear indications in three tubes (Table 7) were again measured and confirmed to have experienced no growth since the 1 R23 examination. This result was expected since no foreign object remains at the location. The indications did not exceed the technical specification plugging limit of 40% TW; consequently, these tubes were returned to service following 1 R24.
No inspection data quality issues or tube restriction issues were experienced; therefore, no tubes required plugging for these causes.
Table 13: Number of Tubes Plugged SGA SGB Total Location Tubes Tubes Tubes Tubes Tubes Tubes Plugged Stabilized Plugged Stabilized Plugged Stabilized Axial ODSCC at EC Support 1
0 1
0 2
0 Axial ODSCC at TTS 6
0 4
0 10 0
Circ ODSCC at TTS 1
1 0
0 1
1 Foreign Object (Note 1) 2 2
0 0
2 2
Foreign Object Wear 3
3 0
0 3
3 Wear at Supports 0
0 0
0 0
0 Obstructed 0
0 0
0 0
0 Total 13 6
5 0
18 6
Note 1: Tubes SGA R31 C162 and SGA R32 C161 were preventatively plugged to bound a foreign object (no wear)
Page 16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Table 14: Specific Tubes Plugged SG Row Col Reason for Plugging Stabilized A
11 110 Axial ODSCC at EC Support No A
31 162 Preventive (adjacent foreign object)
Yes A
32 161 Preventive (adjacent foreign object)
Yes A
33 162 Foreign Object Wear Yes A
37 118 Axial ODSCC at TTS No A
40 117 Axial ODSCC at TTS No A
59 60 Circumferential ODSCC at TTS Yes A
75 86 Axial ODSCC at TTS No A
78 97 Axial ODSCC at TTS No A
83 88 Axial ODSCC at TTS No A
105 98 Axial ODSCC at TTS No A
127 110 Foreign Object Wear Yes A
129 110 Foreign Object Wear Yes B
35 116 Axial ODSCC at TTS No B
49 112 Axial ODSCC at TTS No B
72 93 Axial ODSCC at EC Support No B
75 94 Axial ODSCC at TTS No B
76 91 Axial ODSCC at TTS No
- f.
Total number and percentage of tubes plugged to date The overall plugging status of the Palisades SGs to-date is summarized in Table 15. Because there are no sleeves installed, the total number of tubes plugged and the total number of effective tubes plugged are identical.
Table 15: Overall Plugging Summary SGA SGB Total Total Tubes Installed 8219 8219 16438 Tubes Plugged Pre-Service 308 309 617 Tubes Plugged During Service 242 142 384 Total Tubes Plugged to Date 550 451 1001 Effective Tubes Plugged to Date 550 451 1001 Effective Plugging Percentage 6.7 5.5 6.1 Page 17
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24
- g.
The results of condition monitoring, including the results of tube pulls and in-situ testing No tubes were pulled and, based upon the results of the 1 R24 inspections, no tubes required in-situ pressure testing. The condition monitoring assessment concluded that the structural integrity criteria (TS 5.5.8b.1) and accident induced leakage performance criteria (TS 5.5.8b.2) were satisfied during the operating interval preceding 1 R24. Operational leakage monitoring during cycle 24 indicated stable, low level primary to secondary leakage. The indicated leakage was approximately 5 GPO at the beginning of the cycle and trended downward throughout the cycle to approximately 1.5 GPO. Consequently, the plant specific operational leakage performance criterion (150 GPO, TS 5.5.8b.3, LCO 3.4.13d) was also satisfied throughout the cycle.
- h.
The effective plugging percentage for all plugging in each SG Since no sleeving has been performed in the Palisades steam generators, the effective plugging percentage is the same as the actual plugging percentage (see (f)).
5.0 CONCLUSION
The 180-day steam generator tube inspection report for the Palisades 1 R24 refueling outage is provided in its entirety in Section 4.0 and the appendices, from which it may be copied and modified as necessary by the Palisades Licensing Department.
6.0 REFERENCES
- 1.
AREVA Document 51-9243395-001, "Steam Generator Degradation Assessment for Palisades 1 R24 Inspection, Fall 2015,"
- 2.
AREVA Document 51-9248748-001, "Palisades Steam Generator Condition Monitoring for 1 R24 and Final Operational Assessment for Cycle 25,"
Page 18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX A: ACRONYMS AND ABBREVIATIONS Acronym Definition AVB Anti-Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DDI Dent or Ding with Indication DSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AREVA Data Management System LP Loose Part MRPC Motorized Rotating Pancake Coil (+Pt.')
MBM Manufacturing Burnish Mark NOD No Degradation Detected NOE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWR Pressurized Water Reactor PWSCC Primary Water Stress Corrosion Cracking SAi Single Axial Indication SCI Single Circumferential Indication SGA Steam Generator E-50A SGB Steam Generator E-50B SVI Single Volumetric Indication TBP To Be Plugged TSP Tube Support Plate TTS Top of Tubesheet TW Through Wall
%TW Percent throughwall
<TS Less Than Technical Specification Plugging Limit WAR Wear Indication Page A-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX B: STEAM GENERATOR LAYOUT AND NOMENCLATURE Figure B-1: General Layout of Palisades SG Tube Support Structures DBH DSC OBH 08C 07H 07C OGH 0SC 05H 05C 04H 04C 03H 03C 02H 02C OlH 01C TSH*
TSC TEH*
TEC
___/
Page 8-1
Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 Figure 8-2: Palisades SG Tubesheet Map 160 150 140 130 12!l 110 60 50 40 30 2!l 10 Table 8-1: Palisades SG Tube Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top ofTubesheet-Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS?
Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side DSC Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side Page B-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1R24 APPENDIX C: SUPPORT WEAR LISTING - SGA Depth No SG Row Column
(%TW)
Location Elevation Status 1
A 1
128 15 02C 0.72
<TS 2
A 1
136 15 02H
-1.04
<TS 3
A 1
140 7
DBH
-0.99
<TS 4
A 1
150 13 01C
-0.2
<TS 5
A 1
150 21 02C 0.82
<TS 6
A 1
162 11 01C 0.83
<TS 7
A 2
127 22 05C 0.81
<TS 8
A 2
159 12 03C
-0.16
<TS 9
A 3
128 15 02C 0.79
<TS 10 A
3 164 14 03H
-0.42
<TS 11 A
3 164 13 02C 0.82
<TS 12 A
4 55 14 DBC 0.4
<TS 13 A
4 115 13 04C 0.81
<TS 14 A
4 137 14 02C 0.78
<TS 15 A
4 157 12 02C 0.78
<TS 16 A
4 157 9
02C
-0.11
<TS 17 A
5 130 12 02C 0.87
<TS 18 A
9 2
18 02C 0.07
<TS 19 A
9 32 14 DBC 1.03
<TS 20 A
10 165 17 DBH 1.75
<TS 21 A
11 146 11 03C 0.82
<TS 22 A
12 3
16 02C 0.77
<TS 23 A
12 123 12 DBH 1.41
<TS 24 A
13 2
10 02H
-0.91
<TS 25 A
13 2
18 02H 0.97
<TS 26 A
13 34 17 03C
-1.01
<TS 27 A
13 146 15 DBC
-0.89
<TS 28 A
14 3
25 02C 0.78
<TS 29 A
15 154 11 DBC 1.58
<TS 30 A
18 49 10 VS4
-1.01
<TS 31 A
18 51 15 VS4
-1.05
<TS 32 A
19 56 17 DBC 0.84
<TS 33 A
20 3
14 02C
-0.74
<TS 34 A
21 2
13 04H 0.86
<TS 35 A
21 64 14 DBH
-1.66
<TS 36 A
21 114 12 02H 0.15
<TS 37 A
22 3
16 02C
-1.06
<TS 38 A
22 9
13 02C
-0.97
<TS 39 A
22 53 16 DBH 0.27
<TS 40 A
22 159 16 02H 0.92
<TS 41 A
22 163 13 02H
-0.81
<TS 42 A
23 4
14 02C
-0.87
<TS 43 A
24 33 9
01H 0.84
<TS 44 A
24 161 11 02C
-0.98
<TS 45 A
24 161 15 02C 0.82
<TS 46 A
24 163 18 02C 0.82
<TS 47 A
25 110 15 04C 0.82
<TS 48 A
26 3
19 02C
-1.03
<TS Page C-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 49 A
26 5
14 02H
-0.9
<TS 50 A
26 5
15 02H
-0.13
<TS 51 A
26 121 18 VS4
-0.52
<TS 52 A
26 161 13 03H 0.79
<TS 53 A
26 163 17 01H 0.95
<TS 54 A
27 6
9 02H
-0.72
<TS 55 A
27 8
14 02C
-0.87
<TS 56 A
27 10 9
05H
-0.06
<TS 57 A
27 10 10 05H 1.1
<TS 58 A
28 3
15 02C
-0.94
<TS 59 A
28 19 22 VS4
-0.94
<TS 60 A
28 31 22 VS4
-0.94
<TS 61 A
28 63 17 VS4
-1.07
<TS 62 A
29 122 11 02H 0.87
<TS 63 A
29 162 13 01H
-0.71
<TS 64 A
30 59 10 04C 0.74
<TS 65 A
31 4
13 02H
-0.85
<TS 66 A
31 44 12 02C 0.81
<TS 67 A
31 126 20 VS4
-0.65
<TS 68 A
31 126 10 VS4 0.3
<TS 69 A
31 128 17 VS4
-0.74
<TS 70 A
31 128 21 VS4 1.02
<TS 71 A
32 7
21 02C
-0.97
<:TS 72 A
32 37 7
03H.
0.13
<TS 73 A
32 37 13 03H 0.92
<TS 74 A
32 59 18 DBH 0
<TS 75 A
32 109 12 VS4
-0.26
<TS 76 A
32 145 19 VS4
-0.98
<TS 77 A
32 161 13 03H
-0.11
<TS 78 A
33 22 19 DBH 1.85
<TS 79 A
33 46 16 02H 0.97
<TS 80 A
33 116 13 03H 0.89
<TS 81 A
33 124 9
VS4 0.96
<TS 82 A
33 124 12 03C 0.82
<TS 83 A
34 15 11 VS4
-0.92
<TS 84 A
34 39 12 02H 1.08
<TS 85 A
34 57 11 04H 0.96
<TS 86 A
34 59 10 04H
-0.06
<TS 87 A
34 59 11 04H 0.88
<TS 88 A
34 63 15 DBC 1.72
<TS 89 A
34 109 14 04H 0.96
<TS 90 A
34 117 15 03C
-0.96
<TS 91 A
34 119 13 03H 1
<TS 92 A
34 121 14 03C 0.84
<TS 93 A
34 131 13 05C
-0.2
<TS 94 A
35 114 14 DBC 1.74
<TS 95 A
36 109 8
VS4
-0.04
<TS 96 A
36 117 13 03C 0.11
<TS 97 A
37 6
14 02C 0.89
<TS 98 A
37 6
15 02C
-0.87
<TS 99 A
37 24 15 05C 0.84
<TS 100 A
37 30 8
05H
-0.93
<TS Page C-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 101 A
37 30 8
05H 0.92
<TS 102 A
37 34 20 DBC 1.5
<TS 103 A
37 34 14.
04H 0.98
<TS 104 A
37 36 16 04H
-0.09
<TS 105 A
37 38 18 03C 0.83
<TS 106 A
37 50 6
04H
-0.92
<TS 107 A
37 50 14 04H 0.96
<TS 108 A
37 56 21 04H 0.96
<TS 109 A
37 62 23 04H 0.94
<TS 110 A
37 62 17 05H
-0.69
<TS 111 A
37 106 14 03C
-0.88
<TS 112 A
37 116 16 03C 0.75
<TS 113 A
37 128 23 VS4 1
<TS 114 A
37 128 15 VS4
-0.74
<TS 115 A
38 11 12 05H 0.93
<TS 116 A
38 17 18 05H
-0.04
<TS 117 A
38 35 19 05H 0.91
<TS 118 A
38 35 25 04H 0.87
<TS 119 A
38 35 22 03H 0.91
<TS 120 A
38 45 17 03C
-1
<TS 121 A
38 47 14 02H 0.87
<TS 122 A
38 51 31 04C 0.79
<TS 123 A
38 61 13 04H
-0.11
<TS 124 A
38 115 15 02C 0.83
<TS 125 A
38 119 12 02C 0.68
<TS 126 A
38 127 15 03H 0.91
<TS 127 A
39 10 14 DBH 1.59
<TS 128 A
39 14 13 05H
-0.06
<TS 129 A
39 40 11 02H 0.91
<TS 130 A
39 42 12 04H
-0.8
<TS 131 A
39 42 17 03C
-0.9
<TS 132 A
39 46 13 04H
-0.7
<TS 133 A
39 62 11 05H 0.24
<TS 134 A
39 62 15 05H 1
<TS 135 A
39 112 16 02C 0.72
<TS 136 A
39 120 20 04H 0.83
<TS 137 A
39 126 18 03C 0.82
<TS 138 A
39 130 12 DBC
-1.66
<TS 139 A
40 5
10 01C
-0.93
<TS 140 A
40 7
13 02C 0.82
<TS 141 A
40 35 10 04H 0.87
<TS 142 A
40 49 13 04H 0.9
<TS 143 A
40 59 17 05H 1.08
<TS 144 A
40 115 11 02C 0.78
<TS 145 A
40 125 11 02C 0.8
<TS 146 A
40 147 24 VS4
-0.13
<TS 147 A
40 147 24 VS4
-0.72
<TS 148 A
41 6
15 02C
-0.22
<TS 149 A
41 8
10 02C
-0.2
<TS 150 A
41 16 16 05H
-0.94
<TS 151 A
41 20 14 05H 1.09
<TS 152 A
41 22 9
05H
-0.96
<TS Page C-3
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 153 A
41 34 17 03H
-0.8
<TS 154 A
41 52 26 VS4
-0.71
<TS 155 A
41 60 25 05H 0.92
<TS 156 A
41 108 12 03C 0.82
<TS 157 A
41 126 10 02C
-0.88
<TS 158 A
41 160 18 01H 0.88
<TS 159 A
41 160 9
03C 0.67
<TS 160 A
41 160 13 03C
-0.18
<TS 161 A
42 5
15 02H 0.9
<TS 162 A
42 5
11 VS4
-0.72
<TS 163 A
42 5
10 VS4
-0.02
<TS 164 A
42 7
22 02C 0.81
<TS 165 A
42 7
12 02C 0.02
<TS 166 A
42 35 15 05C 0.97
<TS 167 A
42 41 34 VS4
-0.95
<TS 168 A
42 41 29 VS4 0.95
<TS 169 A
42 43 20 04H 0.86
<TS 170 A
42 45 13 02H 0.99
<TS 171 A
42 45 10 04H 0.96
<TS 172 A
42 59 14 04H 0.88
<TS 173 A
42 117 16 02C 0.74
<TS 174 A
43 44 13 04C 0.68
<TS 175 A
43 46 18 03H
-0.46
<TS 176 A
43 46 33 VS4
-0.66
<TS 177 A
43 46 18 VS4 1.09
<TS 178 A
43 106 13 03C 0.9
<TS 179 A
43 126 31 VS4 0.98
<TS 180 A
44 15 19 DBH
-1.58
<TS 181 A
44 21 28 VS4
-0.88
<TS 182 A
44 21 23 VS4
-0.25
<TS 183 A
44 21 27 VS4 0.7
<TS 184 A
44 49 20 04H 0.94
<TS 185 A
44 49 31 VS4
-0.75
<TS 186 A
44 49 27 VS4
-0.02
<TS 187 A
44 49 23 05C
-0.98
<TS 188 A
44 109 15 03C 0.09
<TS 189 A
44 123 16 06H
-0.07
<TS 190 A
44 123 19 VS4
-0.59
<TS 191 A
44 123 20 VS4 0.04
<TS 192 A
44 123 11 VS4 0.89
<TS 193 A
44 125 9
VS4
-0.48
<TS 194 A
45 12 17 DBH 1.78
<TS 195 A
45 30 14 04H
-0.85
<TS 196 A
45 30 7
04H 0.02
<TS 197 A
45 42 13 VS4 0.82
<TS 198 A
45 60 13 04H 0.98
<TS 199 A
45 108 17 03C 0.75
<TS 200 A
45 122 15 03C
-0.82
<TS 201 A
45 124 20 VS4 0.76
<TS 202 A
45 134 18 03C 0.6
<TS 203 A
46 37 14 03H 0.9
<TS 204 A
46 41 12 04H 0.85
<TS Page C-4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 205 A
46 47 15 02H 0.99
<TS 206 A
46 53 27 VS4
-0.87
<TS 207 A
46 53 23 VS4 0.98
<TS 208 A
46 55 13 VS4
-0.96
<TS 209 A
46 55 20 VS4 0.96
<TS 210 A
46 65 30 VS4 0.99
<TS 211 A
46 69 20 VS4
-0.42
<TS 212 A
46 125 22 VS4 0.04
<TS 213 A
46 125 11 VS4 0.83
<TS 214 A
46 127 11 02C 0.78
<TS 215 A
46 141 18 04C 0.83
<TS 216 A
47 8
18 01H
-0.8
<TS 217 A
47 12 12 DBC 1.66
<TS 218 A
47 24 12 04H
-0.82
<TS 219 A
47 34 11 03C 0.85
<TS 220 A
47 50 16 VS4 0.99
<TS 221 A
47 70 16 04H 0.95
<TS 222 A
47 112 17 02C 0.87
<TS 223 A
47 122 32 VS4 0.92
<TS 224 A
47 122 26 VS4 0.18
<TS 225 A
47 124 24 VS4 0.88
<TS 226 A
47 124 23 VS4 0.07
<TS 227 A
47 124 11 VS4
-0.57
<TS 228 A
47 126 13 04C
-0.02
<TS 229 A
47 126 26 VS4
-0.02
<TS 230 A
47 126 26 VS4
-0.81
<TS 231 A
48 7
24 01C 0.73
<TS 232 A
48 19 12 05H
-0.73
<TS 233 A
48 19 38 VS4
-1.11
<TS 234 A
48 19 29 VS4 0.69
<TS 235 A
48 21 27 VS4
-0.86
<TS 236 A
48 29 18 03C 0.83
<TS 237 A
48 29 17 04H 0.88
<TS 238 A
48 37 9
06H 0.98
<TS 239 A
48 41 38 VS4
-1.06
<TS 240 A
48 41 19 VS4 0.93
<TS 241 A
48 43 36 VS4
-1.02
<TS 242 A
48 43 17 VS4 0.79
<TS 243 A
48 43 9
VS4 0.2
<TS 244 A
48 55 13 04H 0.98
<TS 245 A
48 69 11 VS4
-0.89
<TS 246 A
48 69 36 VS4 0.98
<TS 247 A
48 97 30 VS4 0.88
<TS 248 A
48 111 13 02C 0.7
<TS 249 A
48 123 9
04C 0.8
<TS 250 A
48 125 16 02C 0.09
<TS 251 A
48 125 15 02C 0.78
<TS 252 A
48 159 14 01H
-0.14
<TS 253 A
48 159 9
01H 0.93
<TS 254 A
48 159 7
01H
-0.81
<TS 255 A
49 10 18 VS4 0.99
<TS 256 A
49 20 30 VS4
-0.81
<TS Page C-5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 257 A
49 20 25 VS4 1.04
<TS 258 A
49 24 11 VS4
-0.88
<TS 259 A
49 28 15 03C 0.79
<TS 260 A
49 36 14 03C 0.79
<TS 261 A
49 66 22 VS4 0.16
<TS 262 A
49 66 16 VS4 1.05
<TS 263 A
49 66 9
VS4
-0.66
<TS 264 A
49 70 22 VS4 1.02
<TS 265 A
49 70 11 DBC 1.57
<TS 266 A
49 74 20 VS4
-0.78
<TS 267 A
49 74 13 DBC 1.7
<TS 268 A
49 92 16 03C
-0.96
<TS 269 A
49 112 21 VS4
-0.13
<TS 270 A
49 112 13 VS4
-0.57
<TS 271 A
49 122 7
04C 0.8
<TS 272 A
49 122 9
04C
-0.88
<TS 273 A
50 17 11 VS4
-0.98
<TS 274 A
50 19 14 VS4 0.76
<TS 275 A
50 19 9
DBC 1.59
<TS 276 A
50 21 17 DBH 1.63
<TS 277 A
50 21 11 DBC 1.58
<TS 278 A
50 45 13 03H 0.89
<TS 279 A
50 45 15 VS5
-0.86
<TS 280 A
50 57 12 04H 0.98
<TS 281 A
50
. 91 14 VS4 0.83
<TS 282 A
50 123 19 04C 0.02
<TS 283 A
50 127 12 03C
-0.89
<TS 284 A
50 127 8
03C 0.11
<TS 285 A
50 157 37 VS3
-0.85
<TS 286 A
50 157 21 VS3 0.8
<TS 287 A
51 16 18 VS4
-0.74
<TS 288 A
51 20 31 VS3
-0.78
<TS 289 A
51 20 15 VS5
-0.18
<TS 290 A
51 54 13 04H 0.87
<TS 291 A
51 70 15 05H 0.9
<TS 292 A
51 108 13 03C
-0.83
<TS 293 A
51 118 16 02C
-0.95
<TS 294 A
51 122 16 02C
-0.22
<TS 295 A
51 124 13 04C
-0.92
<TS 296 A
51 126 18 02C 0.07
<TS 297 A
51 126 12 02C 0.81
<TS 298 A
51 126 14 03C
-0.87
<TS 299 A
51 134 10 04C 0.78
<TS 300 A
51 134 9
04C 0.07
<TS 301 A
51 134 13 VS3
-0.77
<TS 302 A
52 9
11 01C
-0.93
<TS 303 A
52 25 9
04H 0.97
<TS 304 A
52 33 13 06H 0.92
<TS 305 A
52 53 13 03H 0.82
<TS 306 A
52 111 20 02C 0.81
<TS 307 A
52 117 21 02C 0.8
<TS 308 A
52 149 16 VS3 1.11
<TS Page C-6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 309 A
52 149 13 VS4
-0.93
<TS 310 A
53 10 12 01H
-0.83
<TS 311 A
53 10 8
VS4
-0.83
<TS 312 A
53 10 8
01C
-0.24
<TS 313 A
53 10 14 01C
-0.97
<TS 314 A
53 24 7
DBH
-1.52
<TS 315 A
53 88 14 03C
-0.91
<TS 316 A
53 92 17 03C 0.73
<TS 317 A
53 118 14 02C 0.8
<TS 318 A
53 122 9
04C 0.82
<TS 319 A
53 122 19 02C
-0.24
<TS 320 A
53 122 6
04C
-0.99
<TS 321 A
54 21 9
DBC 1.51
<TS 322 A
54 29 17 02C 0.7
<TS 323 A
54 33 8
03H 0.9
<TS 324 A
54 39 14 03H 0.97
<TS 325 A
54 77 12 DBC
-1.61
<TS 326 A
54 81 20 DBH 1.89
<TS 327 A
54 83 17 03H 0.93
<TS 328 A
54 83 29 DBH 0.13
<TS 329 A
54 109 14 04C 0.84
<TS 330 A
54 119 15 02C 0.76
<TS 331 A
54 139 10 DBC 1.73
<TS 332 A
55 8
17 01C
-0.28
<TS 333 A
55 46 13 04H
-0.7
<TS 334 A
55 88 15 02C
-1
<TS 335 A
55 120 15 02C
-0.24
<TS 336 A
55 122 17 02C
-0.22
<TS 337 A
55 140 23 06C
-0.18
<TS 338 A
56 27 9
03H
-0.83
<TS 339 A
56 39 14 04H
-0.02
<TS 340 A
56 81 18 DBH 1.75
<TS 341 A
56 115 17 02C 0.82
<TS 342 A
56 115 11 03C
-0.95
<TS 343 A
56 137 16 03C 0.09
<TS 344 A
57 10 12 01C
-0.22
<TS 345 A
57 18 14 VS3
-0.63
<TS 346 A
57 32 9
06H 0
<TS 347 A
57 110 15 02C 0.81
<TS 348 A
57 114 11 03C
-0.95
<TS 349 A
57 142 14 03C 0.84
<TS 350 A
58 33 10 04H
-0.81
<TS 351 A
58 33 10 DBH 1.74
<TS 352 A
58 81 10 03H
-0.08
<TS 353 A
58 85 14 03H 1.01
<TS 354 A
58 121 14 02C 0.87
<TS 355 A
58 123 13 03C 0
<TS 356 A
58 127 25 04C 0.76
<TS 357 A
59 30 17 03C 0.77
<TS 358 A
59 38 15 03H 0.85
<TS 359 A
59 56 12 DBH
-0.81
<TS 360 A
59 106 15 02C 1.02
<TS Page C-7
A Document No.: 51~9252894-001
.AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 361 A
59 114 13 03C 0.81
<TS 362 A
59 114 12 03C
-0.94
<TS 363 A
59 126 12 06H 0.91
<TS 364 A
60 11 14 01C 0
<TS 365 A
60 25 13 04H 0.86
<TS 366 A
60 29 20 04H 0.87
<TS 367 A
60 33 15 DBC 1.49
<TS 368 A
60 39 7
05H
-0.02
<TS 369 A
60 39 11 06H 0.97
<TS 370 A
60 39 14 04H 0.9
<TS 371 A
60 119 20 02C 0.82
<TS 372 A
60 121 17 02C 0.8
<TS 373 A
61 20 9
DBC 1.58
<TS 374 A
61 34 14 03H 0.97
<TS 375 A
61 34 11 04H 0.87
<TS 376 A
61 36 9
03H
-0.8
<TS 377 A
61 40 12 04H 0.91
<TS 378 A
61 44 14 04H
-0.13
<TS 379 A
61 80 9
06H
-0.02
<TS 380 A
61 112 14 04C
-1.03
<TS 381 A
61 138 13 DBC 1.22
<TS 382 A
61 144 11 DBH 1.82
<TS 383 A
61 150 11 DBC 1.3
<TS 384 A
62 11 13 01C
-0.98
<TS 385 A
62 15 9
06C 0.74
<TS 386 A
62 19 14 06H 0.95
<TS 387 A
62 33 17 03H 0.95
<TS 388 A
62 35 11 03H 0.9
<TS 389 A
62 49 12 05H 0.93
<TS 390 A
62 73 11 04H
-0.02
<TS 391 A
63 12 14 01C
-0.97
<TS 392 A
63 40 9
DBC
-1.39
<TS 393 A
63 44 12 06C
-0.96
<TS 394 A
63 52 15 06C 0.78
<TS 395 A
63 58 11 03H 0.96
<TS 396 A
63 66 12 04H
-0.89
<TS 397 A
63 80 8
03H 1.05
<TS 398 A
63 80 6
03H
-0.85
<TS 399 A
63 82 10 06H 0.99
<TS 400 A
63 82 20 03H 0.92
<TS 401 A
63 82 7
02H
-0.87
<TS 402 A
63 84 12 DBH
-1.9
<TS 403 A
63 104 15 03C 0.77
<TS 404 A
63 118 16 03C 0.83
<TS 405 A
63 122 17 03C 0.74
<TS 406 A
63 124 15 04C 0.81
<TS 407 A
63 124 10 04C
-0.11
<TS 408 A
63 126 16 04C 0.82
<TS 409 A
63 134 13 03C 0.77
<TS 410 A
63 136 15 06H
-0.21
<TS 411 A
63 140 18 DBC 1.47
<TS 412 A
63 142 13 04C 0.77
<TS Page C-8
A Docum~nt No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 413 A
64 11 15 VS5 0.73
<TS 414 A
64 11 9
VS4 0.62
<TS 415 A
64 11 29 VS4
-0.94
<TS 416 A
64 11 11 06H 0.87
<TS 417 A
64 13 14 04H 0.88
<TS 418 A
64 13 16 VS4
-0.91
<TS 419 A
64 25 12 06C 0.97
<TS 420 A
64 29 15 DBC 1.68
<TS 421 A
64 37 18 VS5 0.89
<TS 422 A
64 57 13 06C 0.82
<TS 423 A
64 57 11 05H 0.97
<TS 424 A
64 59 11 04C 0.81
<TS 425 A
64 59 13 05C 0.73
<TS 426 A
64 71 9
VS5
-0.88
<TS 427 A
64 71 9
VS5 0.9
<TS 428 A
64 83 10 03H 0.96
<TS 429 A
64 123 17 04C 0.78
<TS 430 A
64 139 13 03C 0.96
<TS 431 A
64 153 11 01C
-1.03
<TS 432 A
65 12 18 06H 0.91
<TS 433 A
65 12 9
01C
-0.23
<TS 434 A
65 14 9
06H 0.95
<TS 435 A
65 16 10 05H 0.84
<TS 436 A
65 24 9
VS5
-0.86
<TS 437 A
65 24 11 VS5 0.68
<TS 438 A
65 32 7
04H 0.88
<TS 439 A
65 32 9
DBC 1.35
<TS 440 A
65 32 6
DBC
-1.26
<TS 441 A
65 40 14 03H 0.97
<TS 442 A
65 76 10 02H
-0.05
<TS 443 A
65 90 16 02C 0.85
<TS 444 A
65 106 19 04C 0.75
<TS 445 A
65 108 16 03H
-0.88
<TS 446 A
65 116 13 VS3 0.9
<TS 447 A
65 126 16 06C
-1.04
<TS 448 A
65 138 27 04C
-0.21
<TS 449 A
65 152 21 VS3 0.98
<TS 450 A
66 13 11 01C
-1.09
<TS 451 A
66 13 11 VS4
-0.8
<TS 452 A
66 25 11 04H 0.89
<TS 453 A
66 27 19 06C 0.79
<TS 454 A
66 31 9
05H
-0.86
<TS 455 A
66 31 16 04H 0.95
<TS 456 A
66 35 13 04H 0.86
<TS 457 A
. 66 37 10 06H 0.07
<TS 458 A
66 39 7
05H 0.93
<TS 459 A
66 55 10 02H 0.85
<TS 460 A
66 59 14 06C 0.81
<TS 461 A
66 75 10 05H 0.93
<TS 462 A
66 77 5
DBC
-1.78
<TS 463 A
66 79 10 01H
-0.14
<TS 464 A
66 79 9
03H
-0.71
<TS Page C-9
- --- ------------------~----
~
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 465 A
66 83 14 06C 0.8
<TS 466 A
66 107 13 03H 0.11
<TS 467 A
66 107 13 02C
-0.99
<TS 468 A
66 109 13 03H
-0.77
<TS 469 A
66 109 13 04C 0.83
<TS 470 A
66 109 13 04C 0.07
<TS 471 A
66 109 17 02C 0.78
<TS 472 A
66 113 12 02C 0.79
<TS 473 A
66 113 14 03H 0.92
<TS 474 A
66 137 12 06C
-0.86
<TS 475 A
67 12 10 03H 0.83
<TS 476 A
67 14 25 05H 0.87
<TS 477 A
67 20 16 VS5 0.69
<TS 478 A
67 24 24 06H 0.93
<TS 479 A
67 24 7
06H 0.17
<TS 480 A
67 32 11 06H 1.04
<TS 481 A
67 34 10 06C 0.84
<TS 482 A
67 38 5
06H
-0.11
<TS 483 A
67 38 10 06H 1.04
<TS 484 A
67 50 12 03C 0.79
<TS 485 A
67 50 8
03C 0.02
<TS 486 A
67 56 11 VS3 0.73
<TS 487 A
67 106 10 02H 0.98
<TS 488 A
67 106 14 03H 0.88
<TS 489 A
67 112 10 VS3 0.86
<TS 490 A
67 114 25 02C 0.85
<TS 491 A
67 118 12 03C 0.85
<TS 492 A
67 120 12 06H
-0.06
<TS 493 A
67 120 15 VS5 1.01
<TS 494 A
67 120 11 06H 1.08
<TS 495 A
67 130 14 DBH 1.87
<TS 496 A
67 136 20 VS3 0.61
<TS 497 A
67 138 11 03C 0.72
<TS 498 A
67 154 17 02C 0.86
<TS 499 A
67 154 18 01C
-0.61
<TS 500 A
67 154 12 04C 0.83
<TS 501 A
68 15 8
05H
-0.09
<TS 502 A
68 17 11 VS4 0.84
<TS 503 A
68 17 5
VS4
-0.89
<TS 504 A
68 17 14 VS3
-0.62
<TS 505 A
68 21 11 VS3
-0.81
<TS 506 A
68 21 20 VS4
-0.87
<TS 507 A
68 21 23 VS4 0.94
<TS 508 A
68 21 18 VS5 0.24
<TS 509 A
68 21 15 VS5 1
<TS 510 A
68 27 10 VS3
-0.69
<TS 511 A
68 39 10 VS3 0.94
<TS 512 A
68 41 13 04H 0.95
<TS 513 A
68 45 16 06H 0.97
<TS 514 A
68 53 13 04H
-0.17
<TS 515 A
68 81 17 03H 0.89
<TS 516 A
68 107 10 03H
-0.06
<TS Page C-10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 517 A
68 139 31 VS3
-0.68
<TS 518 A
68 139 12 VS5
-0.61
<TS 519 A
68 139 31 VS5 0.79
<TS 520 A
68 141 14 DBH 1.77
<TS 521 A
69 22 21 VS3 0.86
<TS 522 A
69 22 26 VS4
-0.93
<TS 523 A
69 22 19 VS4
-0.09
<TS 524 A
69 22 30 VS4 0.8
<TS 525 A
69 22 26 VS5 0.78
<TS 526 A
69 30 14 DBC 1.69
<TS 527 A
69 34 15 DBH 1.71
<TS 528 A
69 34 12 06C 0.8
<TS 529 A
69 40 14 04H 0.97
<TS 530 A
69 40 14 DBH 1.81
<TS 531 A
69 54 16 03C
-1.05
<TS 532 A
69 58 10 02C 0.83
<TS 533 A
69 60 10 06H 0.86
<TS 534 A
69 108 17 04H 1
<TS 535 A
69 126 12 DBC 1.69
<TS 536 A
69 134 18 06C
-1.1
<TS 537 A
69 136 12 VS3
-0.9
<TS 538 A
69 136 13 VS5 0.55
<TS 539 A
69 152 24 VS3
-0.85
<TS 540 A
69 152 24 VS3 0.94
<TS 541 A
70 15 12 VS4
-0.83
<TS 542 A
70 19 11 05H 0.94
<TS 543 A
70 29 7
DBC 1.6
<TS 544 A
70 53 19 03C 0
<TS 545 A
70 53 10 02C
-0.91
<TS 546 A
70 55 18 03C
-0.93
<TS 547 A
70 69 14 05H
-0.02
<TS 548 A
70 81 17 DBC 1.7
<TS 549 A
70 81 10 03H 0.93
<TS 550 A
70 107 11 04H 0.13
<TS 551 A
70 107 14 04C
-0.88
<TS 552 A
70 115 15 DBH 1.81
<TS 553 A
70 119 13 04C 0.86
<TS 554 A
70 129 11 DBC 1.71
<TS 555 A
70 137 16 06H 0.96
<TS 556 A
70 143 18 DBH 1.83
<TS 557 A
70 145 10 DBC
-1.9
<TS 558 A
70 153 22 VS3
-0.91
<TS 559 A
70 153 14 VS3 0.91
<TS 560 A
70 153 15 DBH
-1.63
<TS 561 A
70 153 11 02C
-0.83
<TS 562 A
71 34 7
03H
-0.79
<TS 563 A
71 54 11 04H 1.03
<TS 564 A
71 78 15 06C
-0.93
<TS 565 A
71 108 13 05C 0.81
<TS 566 A
71 108 15 02C
-0.24
<TS 567 A
71 110 12 04H 0.91
<TS 568 A
71 126 19 05C 0.86
<TS Page C-11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 569 A
71 126 9
05C 0.09
<TS 570 A
71 134 15 VS3
-0.72
<TS 571 A
71 150 13 06H 0.91
<TS 572 A
72 29 7
DBC 1.84
<TS 573 A
72 47 13 04C
-0.22
<TS 574 A
72 53 9
04C 0.87
<TS 575 A
72 53 14 04C
-1.14
<TS 576 A
72 53 13 02C 0.86
<TS 577 A
72 55 14 04C
-0.13
<TS 578 A
72 55 16 03C
-0.99
<TS 579 A
72 85 14 05C 0.02
<TS 580 A
72 127 13 VS4
-0.17
<TS 581 A
72 127 17 04C 0.7
<TS 582 A
72 143 15 DBC 1.59
<TS 583 A
72 145 12 DBH 1.68
<TS 584 A
72 149 18 DBH 1.61
<TS 585 A
72 151 12 01H
-0.11
<TS 586 A
73 14 14 VS4 0.98
<TS 587 A
73 14 17 VS4
-0.98
<TS 588 A
73 14 10 03H 0.94
<TS 589 A
73 14 13 05H
-0.88
<TS 590 A
73 44
- 19 06C
-0.95
<TS 591 A
73 66 13 04C 0.72
<TS 592 A
73 152 12 VS3
-0.83
<TS 593 A
73 152 13 VS3 0.98
<TS 594 A
74 15 19 VS4 0.74
<TS 595 A
74 15 10 01C
-0.96
<TS 596 A
74
. 19 14 DBC 1.6
<TS 597 A
74 33 10 DBC 1.26
<TS 598 A
74 79 12 05C
-1
<TS 599 A
74 145 13 DBC 1.34
<TS 600 A
74 149 12 DBC 1.18
<TS 601 A
75 16 19 06C 0
<TS 602 A
75 16 28 VS5
-0.94
<TS 603 A
75 16 17 03H 0.53
<TS 604 A
75 20 15 03H 0.89
<TS 605 A
75 20 12 04H
-0.8
<TS 606 A
75 28 12 DBH 1.71
<TS 607 A
75 32 17 DBH 1.71
<TS 608 A
75 44 36 VS3
-0.7
<TS 609 A
75 44 20 VS3 1.03
<TS 610 A
75 50 18 VS3 0.91
<TS 611 A
75 50 22 VS3
-0.8
<TS 612 A
75 56 13 03C 0.75
<TS 613 A
75 68 16 02C 0.83
<TS 614 A
75 76 11 02H
-0.96
<TS 615 A
75 76 11 02H 0.92
<TS 616 A
75 82 11 03H 0.96
<TS 617 A
75 92 14 06H
-0.62
<TS 618 A
75 110 11 DBC
-1.53
<TS 619 A
75 120 17 03C 0.78
<TS 620 A
75 148 10 06C 0.76
<TS Page C-12
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 621 A
76 15 15 01C 0
<TS 622 A
76 15 34 DBC
-1.69
<TS 623 A
76 15 11 DBC 1.8
<TS 624 A
76 15 10 04H
-0.89
<TS 625 A
76 15 10 03H
-0.18
<TS 626 A
76 15 10 06C 0.82
<TS 627 A
76 17 17 DBC 1.76
<TS 628 A
76 19 10 DBC 1.62
<TS 629 A
76 21 12 03H 0.85
<TS 630 A
76 21 13 04H 0.91
<TS 631 A
76 37 10 06H
-0.04
<TS 632 A
76 51 9
04C
. 0.04
<TS 633 A
76 51 15 VS4 0.89
<TS 634 A
76 51 12 VS3 1
<TS 635 A
76 51 11 VS3
-0.78
<TS 636 A
76 53 14 03C 0.87
<TS 637 A
76 55 23 03C 0.81
<TS 638 A
76 57 12 05C
-0.91
<TS 639 A
76 57 12 02C 0.68
<TS 640 A
76 69 11 04H
-0.07
<TS 641 A
76 91 17 02C 0.83
<TS 642 A
76 97 11 04C 0.89
<TS 643 A
76 97 12 04C
-0.91
<TS 644 A
76 101 18 02H
-0.88
<TS 645 A
76 101 17 03H 0.85
<TS 646 A
76 103 13 03H
-0.06
<TS 647 A
76 111 14 04C 0.79
<TS 648 A
77 16 29 VS4
-0.81
<TS 649 A
77 16 14 DBC 1.93
<TS 650 A
77 18 13 06H
-0.64
<TS 651 A
77 18 16 05H
-0.83
<TS 652 A
77 18 11 07C
-0.02
<TS 653 A
77 20 10 06H
-0.09
<TS 654 A
77 20 8
DBC
-1.21
<TS 655 A
77 22 10 03H 0.92
<TS 656 A
77 22 13 06H 0.99
<TS 657 A
77 24 10 03H 1
<TS 658 A
77 24 9
04H
-0.06
<TS 659 A
77 24 12 06H 0.99
<TS 660 A
77 28 13 06H 0.91
<TS 661 A
77 44 18 VS3 0.93
<TS 662 A
77 44 13 VS4 0.13
<TS 663 A
77 44 25 VS5 0.93
<TS 664 A
77 52 11 02C 0.74
<TS 665 A
77 52 11 03C
-0.98
<TS 666 A
77 52 13 06C
-0.94
<TS 667 A
77 62 15 03C 0.84
<TS 668 A
77 68 9
02H 0.94
<TS 669 A
77 76 11 VS5 0.95
<TS 670 A
77 82 12 05C 0.79
<TS 671 A
77 92 15 02C
-1
<TS 672 A
77 102 15 03H 0.87
<TS Page C-13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 673 A
77 122 19 06C 0.74
<TS 674 A
77 148 17 07H
-0.97
<TS 675 A
77 148 22 03C 0.8
<TS 676 A
78 17 17 DBH
-1.55
<TS 677 A
78 19 13 DBC
-1.62
<TS 678 A
78 25 11 DBC
-1.59
<TS 679 A
78 25 11 05C
-0.9
<TS 680 A
78 75 10 02H 0.14
<TS 681 A
78 101 14 03H 0.95
<TS 682 A
78 113 18 02C 0.76
<TS 683 A
78 149 12 DBC
-1.29
<TS 684 A
79 16 12 DBH
-1.67
<TS 685 A
79 18 14 VS4
-0.82
<TS 686 A
79 18 7
VS4 1.06
<TS 687 A
79 18 13 DBC 1.45
<TS 688 A
79 20 11 05H 0.94
<TS 689 A
79 22 11 07C 0.84
<TS 690 A
79 68 15 07H 0.97
<TS 691 A
79 68 12 04C
-0.91
<TS 692 A
79 72 14 04H 0.91
<TS 693 A
79 72 15 VS3 0
<TS 694 A
79 82 17 03H 0.91
<TS 695 A
79 90 17 04C
-0.15
<TS 696 A
79 94 11 03C
-1.03
<TS 697 A
79 100 14 03H 0.95
<TS 698 A
79 104 14 05H 0.96
<TS 699 A
79 128 21 04C 0.7
<TS 700 A
79 144 12 VS5
-0.77
<TS 701 A
79 144 23 VS5 1.01
<TS 702 A
79 148 10 02C 0.84
<TS 703 A
79 150 19 VS4 1.08
<TS 704 A
79 150 13 02C 0.9
<TS 705 A
79 150 15 02C
-0.09
<TS 706 A
80 17 9
VS4 0.57
<TS 707 A
80 27 16 VS3 1
<TS 708 A
80 57 12 04H 0.11
<TS 709 A
80 57 17 04H 0.92
<TS 710 A
80 59 12 04C 0.75
<TS 711 A
80 65 12 04C 0.77
<TS 712 A
80 71 9
04H
-0.83
<TS 713 A
80 77 9
02H
-0.89
<TS 714 A
80 77 17 04H 0.98
<TS 715 A
80 99 12 07C 0.84
<TS 716 A
80 107 20 DBH 1.78
<TS 717 A
80 119 14 03C 0.79
<TS 718 A
80 143 12 05C 0.86
<TS 719 A
80 145 12 02C
-0.2
<TS 720 A
80 147 14 07H 0.82
<TS 721 A
80 149 18 VS4
-0.84
<TS 722 A
81 18 13 VS4
-0.73
<TS 723 A
81 18 10 DBC
-1.89
<TS 724 A
81 18 12 01H 0.98
<TS Page C-14
A Document No.: 51-9252894-001 A.REV.A Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 725 A
81 20 10 04H 0.88
<TS 726 A
81 20 7
04H
-0.15
<TS 727 A
81 22 7
-1.43
<TS 728 A
81 24 11 DSC
-1.43
<TS 729 A
81 46 16 VS3 0.04
<TS 730 A
81 46 16 VS3 0.84
<TS 731 A
81 46 21 VS5 0.88
<TS 732 A
81 54 17 05C
-1
<TS 733 A
81 70 12 VS4
-0.74
<TS 734 A
81 84 11 04C
-0.98
<TS 735 A
81 84 11 05C
-0.96
<TS 736 A
81 84 19 07C
-0.15
<TS 737 A
81 84 29 VS4 0.92
<TS 738 A
81 94 11 02C
-0.2
<TS 739 A
81 94 17 02C
-0.98
<TS 740 A
81 94 15 DSH 1.86
<TS 741 A
81 100 13 05H 0.88
<TS 742 A
81 102 10 07C
-0.22
<TS 743 A
81 102 17 07C
-0.96
<TS 744 A
81 118 10 VS3
-0.82
<TS 745 A
81 130 21 VS3
-0.69
<TS 746 A
81 130 20 VS3 0.07
<TS 747 A
81 148 17 02C 0.77
<TS 748 A
81 148 22 05C 0.02
<TS 749 A
82 19 7
VS4
-1.04
<TS 750 A
82 19 12 VS4 0.55
<TS 751 A
82 33 11 VS3 1.05
<TS 752 A
82 35 9
VS3 0.2
<TS 753 A
82 61 15 VS3
-0.74
<TS 754 A
82 71 11 VS3 0.97
<TS 755 A
82 89 18 05C 0.79
<TS 756 A
82 91 13 07C 0.85
<TS 757 A
82 101 8
05H
-0.02
<TS 758 A
82 101 10 DSH
-1.99
<TS 759 A
82 107 11 04H 0.87
<TS 760 A
82 121 11 05H 0.9
<TS 761 A
82 135 14 VS3
-0.92
<TS 762 A
82 141 19 VS3
-0.88
<TS 763 A
83 50 10 05C 0.73
<TS 764 A
83 76 14 02H 0.94
<TS 765 A
83 84 14 02C 0.85
<TS 766 A
83 88 17 04C 0.85
<TS 767 A
83 90 11 05H
-0.13
<TS 768 A
83 90 19 07H 0.92
<TS 769 A
83 100 20 04H 0.91
<TS 770 A
83 100 10 05H 0.91
<TS 771 A
83 102 15 05C
-0.18
<TS 772 A
83 102 13 05C
-0.88
<TS 773 A
83 114 10 VS2
-0.85
<TS 774 A
83 116 15 VS2
-0.3
<TS 775 A
83 122 13 VS2 0.82
<TS 776 A
83 130 11 VS2 0.77
<TS Page C-15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 777 A
83 136 11 DBH 1.76
<TS 778 A
83 146 14 04C
-0.85
<TS 779 A
83 148 15 VS4
-0.95
<TS 780 A
83 148 13 VS4
-0.62.
<TS 781 A
83 148 12 07C 0.82
<TS 782 A
83 148 20 03C
-0.9
<TS 783 A
84 19 17 VS5 0.99
<TS 784 A
84 19 22 VS4 0.8
<TS 785 A
84 19 22 VS4
-0.97
<TS 786 A
84 19 11 VS3 0.19
<TS 787 A
84 19 14 VS2 0.6
<TS 788 A
84 19 14 01H
-0.02
<TS 789 A
84 19 12 01H
-0.74
<TS 790 A
84 25 11 VS2 0.61
<TS 791 A
84 29 18 VS2 0.76
<TS 792 A
84 29 15 05C
-1.09
<TS 793 A
84 33 20 VS2
-0.83
<TS 794 A
84 37 16 VS2
-0.88
<TS 795 A
84 39 12 VS2
-0.8
<TS 796 A
84 39 17 VS3
-0.85
<TS 797 A
84 41 14 07H 0.99
<TS 798 A
84 45 11 VS6
-0.78
<TS 799 A
84 47 13 06H 0.95
<TS 800 A
84 51 14 DBH 1.67
<TS 801 A
84 51 10 VS2 0.65
<TS 802 A
84 53 23 VS2
-0.82
<TS 803 A
84 61 28 03C 0.86
<TS 804 A
84 73 13 04H 0.92
<TS 805 A
84 81 9
04H 0.95
<TS 806 A
84 85 18 04H 0.94
<TS 807 A
84 93 13 05C
-0.94
<TS 808 A
84 93 11 05C
-0.22
<TS 809 A
84 99 18 VS2
-0.84
<TS 810 A
84 125 14 04C
-1.02
<TS 811 A
84 141 20 04C 0.86
<TS 812 A
84 143 11 03C 0.88
<TS 813 A
84 147 12 VS5 0.93
<TS 814 A
85 20 24 VS4
-0.89
<TS 815 A
85 20 20 VS4 o.i1
<TS 816 A
85 26 16 03H 0.88
<TS 817 A
85 28 12 VS3
-0.69
<TS 818 A
85 32 10 VS5 1.05
<TS 819 A
85 32 10 03C
-1.01
<TS 820 A
85 40 9
VS5
-0.63
<TS 821 A
85 62 13 04C 0.77
<TS 822 A
85 74 13 05C
-1
<TS 823 A
85 84 13 05H 1.01
<TS 824 A
85 92 17 02C 0.85
<TS 825 A
85 104 19 03C 0.79
<TS 826 A
85 146 16 02C 0.71
<TS 827 A
85 146 23 03C
-0.99
<TS 828 A
86 21 12 VS4
-0.82
<TS Page C-16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 829 A
86 35 14 VS6
-0.7
<TS 830 A
86 55 13 06C 0.8
<TS 831 A
86 65 13 05H 0.99
<TS 832 A
86 69 13 06C
-0.96
<TS 833 A
86 81 12 02H
-0.74
<TS 834 A
86 97 18 03H 0.96
<TS 835 A
86 101 15 04H
-0.81
<TS 836 A
86 101 9
05C
-0.94
<TS 837 A
86 111 13 05C 0.85
<TS 838 A
86 145 17 04C 0.75
<TS 839 A
86 145 9
03C 0.85
<TS 840 A
86 145 11 03C
-0.92
<TS 841 A
86 145 12 02C 0.96
<TS 842 A
87 20 10 VS4
-0.93
<TS 843 A
87 20 16 VS4
-0.35
<TS 844 A
87 20 24 VS4 0.54
<TS 845 A
87 22 12 01H 0.91
<TS 846 A
87 22 14 04H 0.84
<TS 847 A
87 22 19 VS4
-0.94
<TS 848 A
87 36 13 DBH 1.75
<TS 849 A
87 36 10 07C 0.78
<TS 850 A
87 40 14 07H
-0.93
<TS 851 A
87 40 8
VS2
-0.94
<TS 852 A
87 56 9
05H 0.94
<TS 853 A
87 56 12 04C 0.79
<TS 854 A
87 58 14 VS2
-0.84
<TS 855 A
87 60 15 VS2
-0.74
<TS 856 A
87 82 13 05H 0.98
<TS 857 A
87 88 7
04H 0.28
<TS 858 A
87 90 12 04H 0.96
<TS 859 A
87 90 11 04H
-0.13
<TS 860 A
87 92 11 04H
-0.74
<TS 861 A
87 92 10 04H 0.94
<TS 862 A
87 92 15 05C 0.82
<TS 863 A
87 92 19 04C 0.81
<TS 864 A
87 100 18 04H 0.98
<TS 865 A
87 102 12 03H 0.77
<TS 866 A
87 102 11 04H
-0.04
<TS 867 A
87 102 21 05H 0.88
<TS 868 A
87 104 10 06H 0.94
<TS 869 A
87 106 8
06H 0.23
<TS 870 A
87 110 10 03H 0.75
<TS 871 A
87 112 13 04H 0.9
<TS 872 A
87 116 14 03C
-0.11
<TS 873 A
87 116 18 04C 0.83
<TS 874 A
87 120 11 VS2 0.04
<TS 875 A
87 120 16 VS2 0.69
<TS 876 A
87 124 12 04C
-1.11
<TS 877 A
87 142 9
03C
-0.96
<TS 878 A
87 144 21 03C
-0.9
<TS 879 A
87 144 14 04C 0.77
<TS 880 A
87 146 19 VS4
-0.95
<TS Page C-17
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 881 A
87 146 23 VS4 0.58
<TS 882 A
87 146 12 02C 0.77
<TS 883 A
88 21 24 VS4
-0.74
<TS 884 A
88 21 10 VS4 0.32
<TS 885 A
88 33 12 04H 0.91
<TS 886 A
88 53 18 VS4 1.01
<TS 887 A
88 53 22 07C 0.92
<TS 888 A
88 53 14 05C
-0.55
<TS 889 A
88 57 12 06H 0.9
<TS 890 A
88 57 13 VS6 0.73
<TS 891 A
88 57 20 07C 0.9
<TS 892 A
88 59 18 05C 0.8
<TS 893 A
88 59 16 05C 0.07
<TS 894 A
88 59 13 04C 0.59
<TS 895 A
88 61 20 02C 0.84
<TS 896 A
88 61 22 03C 0.44
<TS 897 A
88 73 17 02H
-0.09
<TS 898 A
88 81 11 02C 0.81
<TS 899 A
88 83 13 04H
-0.74
<TS 900 A
88 83 13 05H
-0.84
<TS 901 A
88 89 16 06H 0.94
<TS 902 A
88 91 16 04H 0.94
<TS 903 A
88 99 10 06H
-0.85
<TS 904 A
88 125 13 04C
-0.87
<TS 905 A
88 125 11 03C
-0.96
<TS 906 A
88 145 21 VS4 0.78
<TS 907 A
88 145 24 04C
-0.99
<TS 908 A
88 145 32 02C
-0.18
<TS 909 A
89 26 14 VS6 0.87
<TS 910 A
89 28 13 VS6 0.77
<TS 911 A
89 32 12 03C
-1.05
<TS 912 A
89 34 11 04H
-0.88
<TS 913 A
89 38 9
04H
-0.95
<TS 914 A
89 42 10 07H 0.92
<TS 915 A
89 54 12 07C 0.82
<TS 916 A
89 60 10 04H
-0.77
<TS 917 A
89 72 14 01C 0.74
<TS 918 A
89 78 8
07H
-0.81
<TS 919 A
89 78 17 07H 0.99
<TS 920 A
89 84 12 04H
-0.7
<TS 921 A
89 108 12 04H 1.04
<TS 922 A
89 108 13 05H 0.92
<TS 923 A
89 108 25 06H 0.87
<TS 924 A
89 112 12 05H 0.15
<TS 925 A
89 112 11 05H
-0.85
<TS 926 A
89 112 13 05H 0.91
<TS 927 A
89 128 14 03H 0.82
<TS 928 A
89 136 14 03H 0.91
<TS 929 A
90 23 11 VS4
-0.82
<TS 930 A
90 25 12 VS4 0.98
<TS 931 A
90 31 7
04H 0.9
<TS 932 A
90 35 8
05H 0.89
<TS Page C-18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 933 A
90 59 8
04H
-0.17
<TS 934 A
90 59 12 04H 0.93
<TS 935 A
90 79 7
05H 0.96
<TS 936 A
90 81 11 06H 0.91
<TS 937 A
90 87 14 02C 0.81
<TS 938 A
90 87 12 04C 0.44
<TS 939 A
90 87 17 06H 0.57
<TS 940 A
90 87 17 03H 0.95
<TS 941 A
90 91 11 03C 0.87
<TS 942 A
90 93 20 03C 0.72
<TS 943 A
90 93 14 04C 0.72
<TS 944 A
90 95 11 02C
-0.96
<TS 945 A
90 95 18 04C 0.85
<TS 946 A
90 95 17 06C 0.72
<TS 947 A
90 95 16 07C 0.13
<TS 948 A
90 101 14 02C 0.04
<TS 949 A
90 103 10 04H 0.91
<TS 950 A
90 105 22 05C 0.83
<TS 951 A
90 107 12 04H 0.99
<TS 952 A
90 107 13 05C 0.85
<TS 953 A
90 115 16 VS6
-0.7
<TS 954 A
90 115 16 VS2
-0.75
<TS 955 A
90 135 12 04H 0.9
<TS 956 A
90 135 15 04C 0.78
<TS 957 A
90 143 23 02C
-0.92
<TS 958 A
90 143 17 02C 0.04
<TS 959 A
91 22 35 VS4 0.45
<TS 960 A
91 22 10 VS6
-0.75
<TS 961 A
91 26 9
03H 0.97
<TS 962 A
91 36 12 06H
-0.72
<TS 963 A
91 66 16 05C 0.87
<TS 964 A
91 70 8
06H 0
<TS 965 A
91 70 15 VS6 0.92
<TS 966 A
91 80 14 05C 1.12
<TS 967 A
91 80 10 07C 0.95
<TS 968 A
91 90 20 03C 0.76
<TS 969 A
91 90 10 05H 0.97
<TS 970 A
91 92 13 05H 0.97
<TS 971 A
91 94 13 05H 0.19
<TS 972 A
91 114 15 VS2
-0.8
<TS 973 A
91 116 27 VS2
-0.72
<TS 974 A
91 144 15 VS4 0.68
<TS 975 A
91 144 8
03C
-0.92
<TS 976 A
92 23 22 VS2 0.49
<TS 977 A
92 23 18 VS2 0.84
<TS 978 A
92 23 8
VS6 0.56
<TS 979 A
92 23 27 VS6 0.88
<TS 980 A
92 25 11 VS4
-0.8
<TS 981 A
92 25 14 VS4 0.97
<TS 982 A
92 29 17 03H 0.86
<TS 983 A
92 33 12 04H 0.92
<TS 984 A
92 35 16 06H 0.98
<TS Page C-19 L___
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 985 A
92 37 12 04H 0.89
<TS 986 A
92 51 11 05C 0.02
<TS 987 A
92 59 13 VS4
-0.84
<TS 988 A
92 59 10 VS4 0.17
<TS 989 A
92 59 16 VS4 0.88
<TS 990 A
92 59 13 VS6 1.1
<TS 991 A
92 69 10 05C 0.81
<TS 992 A
92 69 13 05C 0.02
<TS 993 A
92 77 12 05C
-0.95
<TS 994 A
92 77 10 06C
-1
<TS 995 A
92 81 10 05H 0.89
<TS 996 A
92 81 12 06H
-0.78
<TS 997 A
92 85 17 VS6 0.99
<TS 998 A
92 89 16 06H 0.91
<TS 999 A
92 89 16 05C 0.88
<TS 1000 A
92 89 19 04C 0.72
<TS 1001 A
92 101 17 VS2
-0.77
<TS 1002 A
92 101 18 VS2 0.75
<TS 1003 A
92 117 13 VS4
-0.56
<TS 1004 A
92 117 13 VS4 0.95
<TS 1005 A
92 125 14 03H 0.45
<TS 1006 A
92 133 17 07H 0.92
<TS 1007 A
92 133 16 05C
-0.92
<TS 1008 A
92 133 18 04C 0.77
<TS 1009 A
92 135 18 04C 0.64
<TS 1010 A
92 137 10 04C 0.79
<TS 1011 A
92 141 12 04C 0.85
<TS 1012 A
92 141 14 02C
-0.2
<TS 1013 A
93 26 11 VS4
-0.76
<TS 1014 A
93 26 11 VS4 1.02
<TS 1015 A
93 26 10 DBC 1.13
<TS 1016 A
93 52 13 04C 0.75
<TS 1017 A
93 60 22 VS2
-0.65
<TS 1018 A
93 60 22 VS2 1.14
<TS 1019 A
93 60 14 VS6
-0.84
<TS 1020 A
93 60 14 VS6 0.99
<TS 1021 A
93 70 13 02H
-0.8
<TS 1022 A
93 70 10 04H 1.03
<TS I 1023 A
93 76 16 VS4 0.82
<TS 1024 A
93 76 16 VS4 0.23
<TS 1025 A
93 82 13 VS2 1.03
<TS 1026 A
93 84 11 03H
-0.84
<TS 1027 A
93 84 12 04H
-0.82
<TS 1028 A
93 88 11 03H 0.06
<TS 1029 A
93 94 12 04C 0.81
<TS 1030 A
93 100 11 VS2
-0.75
<TS 1031 A
93 104 13 DBH 1.78
<TS 1032 A
93 104 34 VS4
-0.6
<TS 1033 A
93 104 15 VS6
-0.97
<TS 1034 A
93 104 28 VS6 0.94
<TS 1035 A
93 106 21 VS2
-0.63
<TS 1036 A
93 116 10 DBH 1.78
<TS Page C-20
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1037 A
93 130 15 03H
-0.7
<TS 1038 A
93 130 17 VS2 1.08
<TS 1039 A
93 130 20 VS4
-0.73
<TS 1040 A
93 130 39 VS4 1.03
<TS 1041 A
93 130 10 04H
-0.81
<TS 1042 A
93 130 23 VS2
-0.67
<TS 1043 A
93 136 13 03C 0.83
<TS 1044 A
93 136 17 03C
-1.1
<TS 1045 A
93 138 15 05C 0.83
<TS 1046 A
94 25 9
03H
-0.85
<TS 1047 A
94 25 12 VS4
-0.87
<TS 1048 A
94 25 8
VS4
-0.09
<TS 1049 A
94 27 11 03H 0.9
<TS 1050 A
94 31 19 VS4
-0.83
<TS 1051 A
94 51 15 04C 0.75
<TS 1052 A
94 57 11 VS6
-0.83
<TS 1053 A
94 57 12 05C 0.78
<TS 1054 A
94 61 14 04H 0.92
<TS 1055 A
94 67 19 VS6
-0.92
<TS 1056 A
94 67 13 VS6 0.71
<TS 1057 A
94 69 14 05H
-0.82
<TS 1058 A
94 77 27 VS2 1.07
<TS 1059 A
94 77 13 VS2
-0.73
<TS 1060 A
94 77 9
VS6
-0.86
<TS 1061 A
94 85 14 02C 0.76
<TS 1062 A
94 93 16 06C 0.8
<TS 1063 A
94 95 17 07C
-0.92
<TS 1064 A
94 101 21 04C
-1.06
<TS 1065 A
94 107 9
03H
-0.72
<TS 1066 A
95 24 28 VS4
-1.19
<TS 1067 A
95 24 20 VS4 0.11
<TS 1068 A
95 26 12 VS4 0.93
<TS 1069 A
95 30 13 VS6 0.02
<TS 1070 A
95 30 29 VS4 0.9
<TS 1071 A
95 30 35 VS4
-0.79
<TS 1072 A
95 32 7
04H
-0.13
<TS 1073 A
95 48 18 06C 0.86
<TS 1074 A
95 58 11 04H 0.96.
<TS 1075 A
95 58 10 VS2
-0.69
<TS 1076 A
95 60 12 06H 0.9
<TS 1077 A
95 84 18 05C 0.85
<TS 1078 A
95 94 13 DBC 1.67
<TS 1079 A
95 110 10 04H 0.84
<TS 1080 A
95 118 11 VS2 0.3
<TS 1081 A
95 124 18 VS2
-0.73
<TS 1082 A
95 124 21 VS2 0.88
<TS 1083 A
95 126 15 VS2 1
<TS 1084 A
95 130 12 VS2 0.06
<TS 1085 A
95 130 19 VS2 1.11
<TS 1086 A
95 132 18 VS2 1.03
<TS 1087 A
95 132 11 VS4 1.03
<TS 1088 A
95 134 26 04C
-0.99
<TS Page C-21
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1089 A
95 136 24 VS2 1.02
<TS 1090 A
95 136 16 VS2
-0.78
<TS 1091 A
95 140 20 04C 0.64
<TS 1092 A
95 142 12 02C 0.77
<TS 1093 A
95 142 15 02C
-0.07
<TS 1094 A
96 25 17 02H 0.84
<TS 1095 A
96 25 37 VS4 0.78
<TS 1096 A
96 27 12 VS4 1.12
<TS 1097 A
96 31 11 VS4 0.88
<TS 1098 A
96 31 13 VS6
-0.62
<TS 1099 A
96 33 10 06H
-0.95
<TS 1100 A
96 33 11 VS4
-0.86
<TS 1101 A
96 37 15 VS6
-0.74
<TS 1102 A
96 39 10 VS6 0.31
<TS 1103 A
96 41 14 04C 0.77
<TS 1104 A
96 41 14 VS6
-0.17
<TS 1105 A
96 41 18 VS6 1.08
<TS 1106 A
96 55 12 06C
-0.95
<TS 1107 A
96 59 15 07C
-0.88
<TS 1108 A
96 59 19 04C
-0.94
<TS 1109 A
96 61 11 04H 0.21
<TS 1110 A
96 61 12 06H 0.87
<TS 1111 A
96 61 17 06C 0.02
<TS 1112 A
96 63 21 04C 0.74
<TS 1113 A
96 65 11 05H
-0.89
<TS 1114 A
96 73 7
05H 0.96
<TS 1115 A
96 87 15 05H 0.94
<TS 1116 A
96 87 18 05C 0.79
<TS 1117 A
96 91 12 04H
-0.02
<TS 1118 A
96 99 11 04H
-0.08
<TS 1119 A
96 103 14 05C 0.79
<TS 1120 A
96 105 15 07H 0.9
<TS 1121 A
96 105 20 VS6
-0.62
<TS 1122 A
96 109 17 04C 0.86
<TS 1123 A
96 111 19 05C 0.77
<TS 1124 A
96 117 18 VS6
-0.63
<TS 1125 A
96 121 19 VS6 1.15
<TS 1126 A
96 131 21 04C
-1.09
<TS 1127 A
96 141 15 VS4
-0.94
<TS 1128 A
96 141 12 VS4 0.85
<TS 1129 A
97 26 14 VS4
-0.84
<TS 1130 A
97 26 16 VS4 0.5
<TS 1131 A
97 28 8
VS4
-0.49
<TS 1132 A
97 28 15
. VS4 1.01
<TS 1133 A
97 46 9
VS4 0.95
<TS 1134 A
97 46 14 VS6
-0.71
<TS 1135 A
97 46 13 VS6
-0.13
<TS 1136 A
97 48 9
DBC 1.83
<TS 1137 A
97 48 17 VS6 0.97
<TS 1138 A
97 48 16 VS6
-0.84
<TS 1139 A
97 48 18 VS4 0.99
<TS 1140 A
97 48 15 VS4
-0.82
<TS Page C-22
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1141 A
97 50 20 VS6 0.74
<TS 1142 A
97 50 17 VS4 0.96
<TS 1143 A
97 50 18 VS4
-0.74
<TS 1144 A
97 50 14 VS2 0.87
<TS 1145 A
97 50 29 VS2
-0.87
<TS 1146 A
97 52 25 VS6 0.77
<TS 1147 A
97 52 28 VS4
-0.61
<TS 1148 A
97 52 20 VS2 0.83
<TS 1149 A
97 52 8
VS2
-0.86
<TS 1150 A
97 54 14 05C
-0.2
<TS 1151 A
97 58 17 07C 0.89
<TS 1152 A
97 62 19 06C 0.82
<TS 1153 A
97 64 11 05H 0.99
<TS 1154 A
97 64 17 06C
-0.89
<TS 1155 A
97 80 9
01C 0.81
<TS 1156 A
97 82 16 05C 0.79
<TS 1157 A
97 90 7
VS2
-0.09
<TS 1158 A
97 90 15 VS2 0.86
<TS 1159 A
97 90 16 VS4 0.97
<TS 1160 A
97 90 26 VS6
-0.73
<TS 1161 A
97 90 10 VS4
-0.75
<TS 1162 A
97 90 15 05C 0.76
<TS 1163 A
97 96 13 VS2 0.71
<TS 1164 A
97 96 16 VS2 0.19
<TS 1165 A
97 96 15 04C
-0.89
<TS 1166 A
97 100 12 VS2 0.19
<TS 1167 A
97 106 16 VS4 0.91
<TS 1168 A
97 106 26 VS4
-0.83
<TS 1169 A
97 112 15 VS4
-0.89
<TS 1170 A
97 114 14 VS4
-0.89
<TS 1171 A
97 116 20 05C 0.77
<TS 1172 A
97 116 19 VS4
-0.93
<TS 1173 A
97 118 23 VS4 0.64
<TS 1174 A
97 120 13 VS2
-0.8
<TS 1175 A
97 120 25 VS2 1.01
<TS 1176 A
97 120 12 VS4 0.69
<TS 1177 A
97 124 9
VS2
-0.81
<TS 1178 A
97 124 10 VS2 0.96
<TS 1179 A
97 126 15 VS4
-0.04
<TS 1180 A
97 132 12 DBH 1.97
<TS 1181 A
97 132 13 VS4 0.92
<TS 1182 A
97 132 14 04C
-1.01
<TS 1183 A
97 134 20 VS4 0.95
<TS 1184 A
97 136 13 04C
-0.98
<TS 1185 A
97 138 16 02C 0.85
<TS 1186 A
98 27 15 VS6 0.87
<TS 1187 A
98 27 9
VS6
-0.83
<TS 1188 A
98 27 17 VS2 0.63
<TS 1189 A
98 35 11 05H 0.86
<TS 1190 A
98 39 16 05H 0.93
<TS 1191 A
98 51 14 05C 0.84
<TS 1192 A
98 55 10 DBC
-1.68
<TS Page C-23
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1193 A
98 55 12 05H 0.93
<TS 1194 A
98 59 14 05C
-0.99
<TS 1195 A
98 63 17 05C
-0.96
<TS 1196 A
98 65 21 VS2
-0.6
<TS 1197 A
98 75 19 06C 0.81
<TS 1198 A
98 85 17 06C 0.74
<TS 1199 A
98 85 10 DBC 1.68
<TS 1200 A
98 85 12 VS6
-0.72
<TS 1201 A
98 87 21 06C 0.78
<TS 1202 A
98 87 10 06C
-1
<TS 1203 A
98 105 24 04C 0.76
<TS 1204 A
98 105 20 05C
-1
<TS 1205 A
98 109 12 05H
-0.91
<TS 1206 A
98 109 17 05C 0.81
<TS 1207 A
98 111 15 VS2 0.57
<TS 1208 A
98 111 9
VS2
-0.19
<TS 1209 A
98 111 14 07H 0.21
<TS 1210 A
98 113 12 VS2 0.6
<TS 1211 A
98 119 14 VS6 0.84
<TS 1212 A
98 127 19 07H 0.86
<TS 1213 A
99 26 20 VS4
-0.71
<TS 1214 A
99 26 20 VS4
-0.39
<TS 1215 A
99 28 12 VS4 0.95
<TS 1216 A
99 28 10 VS4
-0.37
<TS 1217 A
99 30 12 VS4
-0.88
<TS 1218 A
99 30 7
VS4 0.57
<TS 1219 A
99 36 15 VS4 0.84
<TS 1220 A
99 70 9
06H
-0.05
<TS 1221 A
99 84 17 VS6
-0.92
<TS 1222 A
99 94 14 03C 0.87
<TS 1223 A
99 96 10 07C 0.04
<TS 1224 A
99 104 15 02C
-0.98
<TS 1225 A
99 104 12 02C
-0.04
<TS 1226 A
99 112 16 04C 0.81
<TS 1227 A
99 116 12 VS4
-0.94
<TS 1228 A
99 136 11 VS4
-1.04
<TS 1229 A
99 136 10 VS4 0.52
<TS 1230 A
99 138 17 02C
-1.02
<TS 1231 A
99 138 13 02C 0.07
<TS 1232 A
99 138 15 03C
-0.41
<TS 1233 A
99 138 19 VS4 0
<TS 1234 A
99 138 16 VS4 0.86
<TS 1235 A
99 138 12 03H 0.9
<TS 1236 A
99 140 26 VS4
-0.55
<TS 1237 A
99 140 19 03C
-0.2
<TS 1238 A
99 140 13 03C
-0.96
<TS 1239 A
100 27 28 VS4
-0.8
<TS 1240 A
100 27 14 VS4
-0.09
<TS 1241 A
100 27 16 VS4 1.1
<TS 1242 A
100 29 16 04H 0.87
<TS 1243 A
100 29 16 05H 0.81
<TS 1244 A
100 29 19 06H 0.88
<TS Page C-24
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1245 A
100 29 13 VS2
-0.9
<TS 1246 A
100 29 22 VS2 0.88
<TS 1247 A
100 29 11 VS4 0
<TS 1248 A
100 29 18 VS4 0.88
<TS 1249 A
100 31 12 04H 0.87
<TS 1250 A
100 31 11 06H
-0.85
<TS 1251 A
100 31 14 06H
-0.09
<TS 1252 A
100 31 14 VS2
-0.88
<TS 1253 A
100 33 11 VS2
-0.91
<TS 1254 A
100 35 12 05C 0
<TS 1255 A
100 35 13 03H
-0.74
<TS 1256 A
100 41 12 06C 0.73
<TS 1257 A
100 49 13 05C 0.81
<TS 1258 A
100 51 8
06H 0
<TS 1259 A
100 61 9
03H
-0.83
<TS 1260 A
100 65 10 06H
-0.9
<TS 1261 A
100 67 30 VS6
-0.81
<TS 1262 A
100 87 11 05C 0.83
<TS 1263 A
100 89 16 VS2
-0.75
<TS 1264 A
100 89 14 03C 0.81
<TS 1265 A
100 103 20 02C 0.74
<TS 1266 A
100 103 16 05C
-0.94
<TS 1267 A
100 107 17 VS4
-0.77
<TS 1268 A
100 113 15 DBH 1.91
<TS 1269 A
100 115 15 05H
-0.85
<TS 1270 A
100 119 22 VS2
-0.69
<TS 1271 A
100 119 24 VS2 0.13
<TS 1272 A
100 119 10 VS2 0.86
<TS 1273 A
100 119 12 VS4
-0.64
<TS 1274 A
100 119 12 VS6 0.99
<TS 1275 A
100 131 12 05C 0.71
<TS 1276 A
100 137 16 05C
-0.86
<TS 1277 A
100 137 9
VS4 0.97
<TS 1278 A
100 137 11 VS4
-0.82
<TS 1279 A
100 137 33 03C
-0.6
<TS 1280 A
100 139 20 VS4
-0.83
<TS 1281 A
100 139 17 03C
-0.17
<TS 1282 A
101 28 13 03H 0.82
<TS 1283 A
101 28 19 VS4
-0.88
<TS 1284 A
101 28 23 VS4 0.67
<TS 1285 A
101 30 18 04H
-0.11
<TS 1286 A
101 30 17 VS4
-0.93
<TS 1287 A
101 30 13 VS4 0.71
<TS 1288 A
101 36 7
03H 0.9
<TS 1289 A
101 40 9
05H 0.13
<TS 1290 A
101 44 13 VS2 0.76
<TS 1291 A
101 48 12 DBC 1.79
<TS 1292 A
101 56 15 06C
-0.95
<TS 1293 A
101 68 10 06H 0.96
<TS 1294 A
101 70 14 05H 0.96
<TS 1295 A
101 70 11 07C
-0.61
<TS 1296 A
101 78 6
07H
-0.77
<TS Page C-25
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1297 A
1D1 78 s
D7H D.2S
<TS 1298 A
1D1 86 11 D7C D.7S
<TS 1299 A
1D1 106 16 D4C D.84
<TS 13DD A
1D1 110 12 VS2 D.74
<TS 13D1 A
1D1 110 12 VS2 D.1S
<TS 13D2 A
1D1 118 1S DBH 1.89
<TS 13D3 A
1D1 124 12 D7C D.7S
<TS 13D4 A
1D1 128 12 D4H
-D.83
<TS 13DS A
1D1 136 11 D3C
-1.D6
<TS 13D6 A
1D1 136 14 D2C D
<TS 13D7 A
1D1 138 2D VS4 D.8S
<TS 13D8 A
1D1 138 11 D7C D.79
<TS 13D9 A
1D2 29 26 VS4
-D.82
<TS 131D A
1D2 29 16 D4C
-1.D1
<TS 1311 A
1D2 29 1D VS4
-D.D9
<TS 1312 A
1D2 31 9
D2C D.7S
<TS 1313 A
1D2 31 9
D7C D.87
<TS 1314 A
1D2 31 9
D3H D.94
<TS 131S A
1D2 67 1S D7H D.9
<TS 1316 A
1D2 73 16 D7C
-D.92
<TS 1317 A
1D2 7S 13 VS2
-D.66
<TS 1318 A
1D2 89 16 D4C D.76
<TS 1319 A
1D2 91 12 D4C
-D.94
<TS 132D A
1D2 9S 13 DSC
-D.2
<TS 1321 A
1D2 10S 1D D2C D.D2
<TS 1322 A
1D2 1DS 12 D3C
-1
<TS 1323 A
1D2 1DS 8
D3C
-D.D2
<TS 1324 A
1D2 10S 17 DSC D.76
<TS 132S A
1D2 107 13 VS2 D.72
<TS 1326 A
1D2 113 13 DSC D.74
<TS 1327 A
1D2 11S 2D VS2
-D.D6
<TS 1328 A
1D2 11S 1S VS2
-D.68
<TS 1329 A
1D2 117 22 D3H D.98
<TS 133D A
1D2 121 22 VS4
-D.81
<TS 1331 A
1D2 13S 16 D4C D.8
<TS 1332 A
102 13S 1S D3C
-D.1S
<TS 1333 A
1D2 137 14 D4C
-D.96
<TS 1334 A
103 3D 16 VS4 D.S3
<TS 133S A
103 3D 14 DSH
-D.84
<TS 1336 A
1D3 3D 12 D7H
-D.86
<TS 1337 A
103 3D 8
VS4
-D.13
<TS 1338 A
103 32 18 VS4
-1.D2
<TS 1339 A
103 32 10 VS4 D.S
<TS 134D A
103 32 11 D3C D.2
<TS 1341 A
103 32 13 D2C
-D.22
<TS 1342 A
1D3 36 9
VS2
-D.89
<TS 1343 A
103 36 14 VS2 D.89
<TS 1344 A
103 36 13 DSC
-D.93
<TS 134S A
103 S4 11 DSH D.89
<TS 1346 A
103 82 1D DSH
-D.84
<TS 1347 A
103 82 17 DSH D
<TS 1348 A
1D3 82 13 D6H 1.D7
<TS Page C-26
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1349 A
103 86 16 VS2 0.67
<TS 1350 A
103 86 13 VS2 0.17
<TS 1351 A
103 92 12 05C 0.76
<TS 1352 A
103 96 13 05C 0.81
<TS 1353 A
103 108 13 07C
-0.22
<TS 1354 A
103 122 18 DBC 1.46
<TS 1355 A
103 134 14 04C 0.09
<TS 1356 A
103 134 13 04C 0.83
<TS 1357 A
103 136 13 DBH
-1.66
<TS 1358 A
104 31 21 VS4
-0.88
<TS 1359 A
104 31 20 VS4 0.82
<TS 1360 A
104 33 12 04C
-0.88
<TS 1361 A
104 33 12 03C
-0.95
<TS 1362 A
104 61 12 06C 0.81
<TS 1363 A
104 69 8
07H
-0.8
<TS 1364 A
104 71 11 DBH 1.83
<TS 1365 A
104 79 10 07H 0.02
<TS 1366 A
104 85 11 VS2
-0.77
<TS 1367 A
104 85 9
04C 0.79
'<TS 1368 A
104 85 21 04C
-0.92
<TS 1369 A
104 87 13 04C
-0.17
<TS 1370 A
104 87 23 04C
-0.96
<TS 1371 A
104 89 15 02C
-0.96
<TS 1372 A
104 95 18 VS2
-0.6
<TS 1373 A
104 97 20 04C
-0.92
<TS 1374 A
104 97 11 03C 0.74
<TS 1375 A
104 97 6
03C 0
<TS 1376 A
104 99 14 06C 0.79
<TS 1377 A
104 103 13 05C 0.83
<TS 1378 A
104 109 17 VS6
-0.52
<TS 1379 A
104 121 12 06C 0.78
<TS 1380 A
104 123 16 04C 0.89
<TS 1381 A
104 135 27 03C 0.72
<TS 1382 A
105 30 25 VS4
-0.56
<TS 1383 A
105 32 14 01C 0.02
<TS 1384 A
105 32 12 04H
-0.9
<TS 1385 A
105 90 18 05C 0.77
<TS 1386 A
105 92 14 07C
-0.9
<TS 1387 A
105 122 10 06C 0.72
<TS 1388 A
105 132 21 03C 0.77
<TS 1389 A
105 136 15 VS4
-0.72
<TS 1390 A
105 136 15 VS4 1.09
<TS 1391 A
106 31 9
VS2 0.19
<TS 1392 A
106 31 16 VS4 0.99
<TS 1393 A
106 31 34 VS6
-0.89
<TS 1394 A
106 31 19 VS6 0.22
<TS 1395 A
106 31 32 VS6 0.76
<TS 1396 A
106 31 21 04C 0.71
<TS 1397 A
106 31 12 03C 0.74
<TS 1398 A
106 31 15 01C
-0.97
<TS 1399 A
106 33 17 VS4
-0.61
<TS 1400 A
106 33 11 VS4
-0.92
<TS Page C-27
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1401 A
106 33 11 04C
-0.92
<TS 1402 A
106 35 16 03C
-0.09
<TS 1403 A
106 35 18 03C 0.68
<TS 1404 A
106 45 11 05H
-0.13
<TS 1405 A
106 47 14 04C 0.02
<TS 1406 A
106 47 14 04C 0.73
<TS 1407 A
106 47 11 DBC 1.62
<TS 1408 A
106 57 19 07H 1.05
<TS 1409 A
106 59 6
DBH 1.89
<TS 1410 A
106 59 14 VS2
-0.87
<TS 1411 A
106 59 22 VS4
-1.11
<TS 1412 A
106 59 35 VS4 0.96
<TS 1413 A
106 59 22 VS6
-0.69
<TS 1414 A
106 63 12 VS4
-0.94
<TS 1415 A
106 63 15 VS4 0.34
<TS 1416 A
106 67 19 VS6 0.39
<TS 1417 A
106 67 10 VS4
-0.51
<TS 1418 A
106 69 15 VS2 0.62
<TS 1419 A
106 69 14 VS4
-1.1
<TS 1420 A
106 69 12 VS6 0.92
<TS 1421 A
106 69 13 07C
-0.23
<TS 1422 A
106 101 14 04H 0.86
<TS 1423 A
106 117 14 VS2
-0.15
<TS 1424 A
106 117 17 06C
-1.04
<TS 1425 A
106 119 11 VS4 1.14
<TS 1426 A
106 121 9
04C
-0.02
<TS 1427 A
106 121 17 05C 0.48
<TS 1428 A
106 121 17 04C 0.73
<TS 1429 A
106 131 11 03C
-0.82
<TS 1430 A
106 133 19 DBC 1.44
<TS 1431 A
106 135 10 01H 0.13
<TS 1432 A
106 135 26 VS4
-0.59
<TS 1433 A
107 32 35 VS4
-0.65
<TS 1434 A
107 32 12 VS4
-0.15
<TS 1435 A
107 32 16 04C
-0.24
<TS 1436 A
107 32 9
04C
-0.85
<TS 1437 A
107 32 13 03C 0.83
<TS 1438 A
107 34 10 VS4 0.96
<TS 1439 A
107 34 9
01H 0.95
<TS 1440 A
107 36 10 03C 0.81
<TS 1441 A
107 40 9
VS2
-0.87
<TS 1442 A
107 44 12 05H
-0.93
<TS 1443 A
107 44 15 05H
-0.15
<TS 1444 A
107 44 9
VS4 0.89
<TS 1445 A
107 44 12 VS2 0.68
<TS 1446 A
107 92 11 05C 0.76
<TS 1447 A
107 120 13 DBH 1.98
<TS 1448 A
107 122 11 03C
-0.19
<TS 1449 A
107 124 12 VS2
-0.97
<TS 1450 A
107 124 17 VS2
-0.15
<TS 1451 A
107 124 11 VS2 0.6
<TS 1452 A
107 124 13 03C
-0.96
<TS I
Page C-28
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1453 A
107 128 13 04C
-1.13
<TS 1454 A
107 130 20 VS2
-0.92
<TS 1455 A
107 130 9
VS2 0.62
<TS 1456 A
107 134 14 03H 0.91
<TS 1457 A
107 134 24 VS4
-0.94
<TS 1458 A
107 134 17 VS4 0.87
<TS 1459 A
107 134 26 02C
-1
<TS 1460 A
108 33 12 01H 0.89
<TS 1461 A
108 33 33 VS4
-0.82
<TS 1462 A
108 33 27 VS4 0.95
<TS 1463 A
108 35 14 VS4
-0.87
<TS 1464 A
108 35 11 VS4 1
<TS 1465 A
108 35 20 01C 0.79
<TS 1466 A
108 35 29 01C 0
<TS 1467 A
108 39 9
04H 0.88
<TS 1468 A
108 41 18 VS4 0.95
<TS 1469 A
108 63 10 VS2 0.21
<TS 1470 A
108 63 17 VS2 0.81
<TS 1471 A
108 65 14 DBH 1.77
<TS 1472 A
108 69 13 07C 0.76
<TS 1473 A
108 87 14 05C 0.74
<TS 1474 A
108 89 14 06C
-0.99
<TS 1475 A
108 93 17 06C 0.35
<TS 1476 A
108 95 14 03C 0.85
<TS 1477 A
108 99 9
DBH 1.9
<TS 1478 A
108 115 16 05H 0.97
<TS 1479 A
108 117 13 05C 0.85
<TS 1480 A
108 123 18 VS2
-0.69
<TS 1481 A
108 133 12 04C 0.7
<TS 1482 A
108 133 17 04C
-0.96
<TS 1483 A
109 34 14 01H 0.94
<TS 1484 A
109 34 12 04H
-0.84
<TS 1485 A
109 34 15 05H
-0.76
<TS 1486 A
109 34 12 VS4
-0.87
<TS 1487 A
109 34 34 VS4 0.63
<TS 1488 A
109 34 12 01C 0.83
<TS 1489 A
109 90 12 07C
-0.09
<TS 1490 A
109 90 9
07C
-0.9
<TS 1491 A
109 98 27 VS2
-0.8
<TS 1492 A
109 118 17 04C
-1
<TS 1493 A
109 120 18 03C
-0.17
<TS 1494 A
109 132 21 04C 0.66
<TS 1495 A
110 35 16 01H 0.91
<TS 1496 A
110 35 14 VS4 0.92
<TS 1497 A
110 39 20 VS2 0.87
<TS 1498 A
110 91 14 04C
-0.9
<TS 1499 A
110 123 23 08H
-0.92
<TS 1500 A
110 131 17 01H 0.21
<TS 1501 A
110 131 32 DBH
-1.8
<TS 1502 A
110 131 17 03C 0.79
<TS 1503 A
111 44 16 06C
-0.18
<TS 1504 A
111 62 18 VS2
-0.74
<TS Page C-29
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1505 A
111 110 15 VS4
-0.94
<TS 1506 A
111 116 20 03H 0.92
<TS 1507 A
111 126 15 04C 0.78
<TS 1508 A
111 128 11 VS4 1.02
<TS 1509 A
111 128 12 03C 0.87
<TS 1510 A
111 128 21 03C
-0.9
<TS 1511 A
111 130 21 04C
-0.19
<TS 1512 A
112 37 22 02C
-0.99
<TS 1513 A
112 37 13 DBH
-1.63
<TS 1514 A
112 39 7
VS6 0.97
<TS 1515 A
112 41 11 VS6
-0.79
<TS 1516 A
112 41 19 VS4
-0.92
<TS 1517 A
112 59 20 VS4
-0.84
<TS 1518 A
112 59 23 VS4 0.06
<TS 1519 A
112 59 33 VS6 1.03
<TS 1520 A
112 65 13 VS4
-0.78
<TS 1521 A
112 65 12 VS4 0.73
<TS 1522 A
112 89 14 VS4
-0.81
<TS 1523 A
112 89 11 04C
-0.9
<TS 1524 A
112 103 14 04H 0.88
<TS 1525 A
112 125 11 05C
-0.89
<TS 1526 A
112 125 12 04C 0.85
<TS 1527 A
112 127 18 05C
-1.07
<TS 1528 A
112 129 14 04C 0.77
<TS 1529 A
113 36 16 01H 0.93
<TS 1530 A
113 36 19 VS4
-0.54
<TS 1531 A
113 36 12 01H
-0.1
<TS 1532 A
113 38 9
01C
-1.07
<TS 1533 A
113 38 10 02C 0.79
<TS 1534 A
113 42 13 VS4
-0.84
<TS 1535 A
113 42 13 VS4 1.06
<TS 1536 A
113 68 18 VS2
-0.66
<TS 1537 A
113 68 12 VS4
-0.8
<TS 1538 A
113 68 15 VS6 1.03
<TS 1539 A
113 76 16 VS6 0.87
<TS 1540 A
113 90 12 VS4
-0.54
<TS 1541 A
113.
90 14 03C
-0.94
<TS 1542 A
113 118 16 04C 0
<TS 1543 A
113 128 18 04H
-0.82
<TS 1544 A
113 128 14 03H 0.97
<TS 1545 A
113 130 21 VS4
-0.64
<TS 1546 A
113 130 23 VS4
-0.26
<TS 1547 A
114 47 10 05H 0.97
<TS 1548 A
114 119 12 03C 0.73
<TS 1549 A
114 123 18 03C
-1.1
<TS 1550 A
114 129 14 08H
-0.9
<TS 1551 A
114 129 24 VS4
-0.86
<TS 1552 A
114 129 12 VS4 1.06
<TS 1553 A
115 38 14 VS4 0.49
<TS 1554 A
115 38 14 VS4 0.83
<TS 1555 A
115 38 16 02C
-0.04
<TS 1556 A
115 38 17 02C
-1.01
<TS Page C-30
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1SS7 A
11S 46 14 VS4
-0.87
<TS 1SS8 A
11S so 10 VS4
-0.6S
<TS 1SS9 A
11S 78 16 06H
-0.?S
<TS 1S60 A
11S 90 11 VS2
-1.07
<TS 1S61 A
11S 9D 38 VS4
-0.77
<TS 1S62 A
11S 92 2S VS1 D.97
<TS 1S63 A
11S 124 12 DSC D.79
<TS 1S64 A
11S 124 17 D4C
-1.D2
<TS 1S6S A
11S 124 13 D3C D.74
<TS 1S66 A
11S 128 1D DSH D.86
<TS 1S67 A
116 39 1S VS6
-D.6S
<TS 1S68 A
116 39 34 D2C
-D.9
<TS 1S69 A
116 39 13 D1C
-D.18
<TS 1S7D A
116 4S 1S D2H D.87
<TS 1S71 A
116 4S 14 VS?
D.86
<TS 1S72 A
116 S1 17 D7H D.82
<TS 1S73 A
116 S1 12 DSH
-D.13
<TS 1S74 A
116 SS 12 DSH
-D.66
<TS 1S7S A
116 61 8
VS4 D.93
<TS 1S76 A
116 63 12 VS6
-D.83
<TS 1S77 A
116 71 9
VS4 D.82
<TS 1S78 A
116 81 11 VS6
-D.8
<TS 1S79 A
116 9S 16 D7C
-D.99
<TS 1S8D A
116 9S 11 D6C D.7
<TS 1S81 A
116 10S 2S VS4
-D.97
<TS 1S82 A
116 111 1S DSC
-D.1S
<TS 1S83 A
116 119 19 D3C D.94
<TS 1S84 A
116 121 13 VS?
D.9
<TS 1S8S A
116 121 2S D4C D.78
<TS 1S86 A
116 123 19 D6C O.S
<TS 1S87 A
117 4D 23 VS4
-D.67
<TS 1S88 A
117 4D 26 D2C D.79
<TS 1S89 A
117 4D 10 D2C
-D.28
<TS 1S9D A
117 42 10 D2C D.81
<TS 1S91 A
117 42 33 D1C
-1.D4
<TS 1S92 A
117 SD 11 VS4
-D.6S
<TS 1S93 A
117 S8 12 D6C D.82
<TS 1S94 A
117 7D 13 D6C D.79
<TS 1S9S A
117 9D 11 VS2 D.82
<TS 1S96 A
117 12D 11 D3H D.82
<TS 1S97 A
117 122 13 VS4 D.13
<TS 1S98 A
118 41 29 D2C D
<TS 1S99 A
118 41 2D VS4
-D.8
<TS 16DD A
118 41 12 D1H 1.DS
<TS 16D1 A
118 43 32 D1C
-D.96
<TS 16D2 A
118 43 9
D3H D.94
<TS 16D3 A
118 43 11 D6H
-D.92
<TS 16D4 A
118 47 14 D2H D.81
<TS 16DS A
118 S1 14 D6C D.78
<TS 16D6 A
118 S3 9
VS6
-D.78
<TS 16D7 A
118 63 19 VS4
-D.94
<TS 16D8 A
118 63 14 VS4 D.92
<TS Page C-31
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1609 A
118 97 12 VS2
-0.94
<TS 1610 A
118 99 18 VS2 0.84
<TS 1611 A
118 101 11 04H
-0.13
<TS 1612 A
118 101 12 VS4 0.94
<TS 1613 A
118 105 18 04C 0.87
<TS 1614 A
118 125 20 VS?
-0.91
<TS 1615 A
119 42 14 VS4
-0.89
<TS 1616 A
119 44 10 02H 0.75
<TS 1617 A
119 52 25 06C 0.82
<TS 1618 A
119 60 14 VS4
-0.78
<TS 1619 A
119 60 13 VS4 1.11
<TS 1620 A
119 76 11 06C 0.79
<TS 1621 A
119 82 11 VS4 0.32
<TS 1622 A
119 110 17 04C
-0.93
<TS 1623 A
119 122 12 06H 0.81
<TS 1624 A
119 122 12 03C 0.63
<TS 1625 A
119 124 13 VS4
-0.8
<TS 1626 A
120 45 11 02H 0.87
<TS 1627 A
120 81 9
VS4 0.91
<TS 1628 A
120 89 17 06C
-0.94
<TS 1629 A
120 93 16 06C 0.85
<TS 1630 A
120 111 10 03C
-0.97
<TS 1631 A
120 111 13 04C
-0.02
<TS 1632 A
120 115 17 05C
-1.01
<TS 1633 A
120 119 21 03C 0.84
<TS 1634 A
120 121 22 05C 0.79
<TS 1635 A
120 123 16 01H
-0.08
<TS 1636 A
121 44 22 VS4 0
<TS 1637 A
121 44 10 VS4 0.83
<TS 1638 A
121 44 17 01C
-1.04
<TS 1639 A
121 44 11 VS?
0.87
<TS 1640 A
121 64 7
07H 0.85
<TS 1641 A
121 76 10 VS6 0.89
<TS 1642 A
121 104 12 VS4 0.58
<TS 1643 A
121 116 23 03C 0.79
<TS 1644 A
121 118 32 VS4
-0.74
<TS 1645 A
121 118 21 VS4
-0.07
<TS 1646 A
121 118 17 VS4 0.74
<TS 1647 A
121 118 27 03C 0.81
<TS 1648 A
121 120 12 06H 0.9
<TS 1649 A
122 45 13 01C 0.81
<TS 1650 A
122 53 11 06H 0.89
<TS 1651 A
122 63 11 05H 0.16
<TS 1652 A
122 81 20 VS4 0.98
<TS 1653 A
122 113 10 03C 0.74
<TS 1654 A
122 117 13 VS1 0.96
<TS 1655 A
122 117 17 VS2
-0.82
<TS 1656 A
122 117 8
VS2 0.04
<TS 1657 A
123 52 11 06H
-0.87
<TS 1658 A
123 110 12 VS2 0.85
<TS 1659 A
123 110 13 06C
-0.26
<TS 1660 A
123 114 11 04C
-1
<TS Page C-32 l
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1661 A
123 120 13 02H 0.87
<TS 1662 A
123 120 11 VS4
-0.62
<TS 1663 A
124 49 13 01H 0.92
<TS 1664 A
124 51 11 03H 0.96
<TS 1665 A
124 117 15 03C
-0.02
<TS 1666 A
124 119 12 VS4
-0.75
<TS 1667 A
125 48 23 VS4
-0.71
<TS 1668 A
125 110 23 03C 0.76
<TS 1669 A
125 112 16 VS6
-0.7
<TS 1670 A
125 112 20 07H
-0.19
<TS 1671 A
125 112 17 03C 0.04
<TS 1672 A
125 114 10 03H
-0.17
<TS 1673 A
126 51 12 VS2 0.8
<TS 1674 A
126 51 10 01H 0.09
<TS 1675 A
126 51 20 03H 0.92
<TS 1676 A
126 63 10 07H 0.89
<TS 1677 A
126 69 14 VS4
-0.8
<TS 1678 A
126 69 35 VS4 0.89
<TS 1679 A
126 77 10 VS1
-0.89
<TS 1680 A
126 77 14 VS1 0.91
<TS 1681 A
126 103 11 VS1 1.01
<TS 1682 A
126 103 33 VS4
-0.82
<TS 1683 A
126 111 19 VS?
1.05
<TS 1684 A
126 115 21 02C
-0.96
<TS 1685 A
126 115 17 04C 0.81
<TS 1686 A
126 115 14 VS6
-0.74
<TS 1687 A
127 52 8
03C
-0.18
<TS 1688 A
127 56 12 DBH 2.07
<TS 1689 A
127 56 8
VS1 0.76
<TS 1690 A
127 56 10 VS1
-0.8
<TS 1691 A
127 56 12 VS4 1.09
<TS 1692 A
127 56 13 VS6 0.87
<TS 1693 A
127 72 19 VS6
-0.23
<TS 1694 A
127 76 11 VS1
-0.98
<TS 1695 A
127 76 11 VS4 1.07
<TS 1696 A
127 80 13 VS?
0.78
<TS 1697 A
127 80 15 06C 0.84
<TS 1698 A
127 98 13 04C
-1
<TS 1699 A
127 106 15 VS4
-0.54
<TS 1700 A
127 108 17 05C
-1.05
<TS 1701 A
127 110 28 VS2
-0.85
<TS 1702 A
127 110 14 VS2 0.83
<TS 1703 A
127 110 13 VS4
-0.13
<TS 1704 A
127 110 13 VS4
-0.62
<TS 1705 A
127 112 27 03C
-0.93
<TS 1706 A
127 114 19 VS4
-0.11
<TS 1707 A
128 53 20 02H
-0.96
<TS 1708 A
128 55 10 VS1
-0.82
<TS 1709 A
128 55 12 VS6
-0.09
<TS 1710 A
128 55 14 VS?
1.16
<TS 1711 A
128 69 14 08H 0.96
<TS 1712 A
128 71 19 VS1
-0.96
<TS Page C-33
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1713 A
128 71 31 VS1 0.85
<TS 1714 A
128 71 17 VS2 0
<TS 1715 A
128 77 16 07C 0.9
<TS 1716 A
128 85 14 DBH 1.86
<TS 1717 A
128 101 13 VS2
-0.71
<TS 1718 A
128 103 10 VS2 0.88
<TS 1719 A
128 111 15 05C 0.7
<TS 1720 A
129 54 30 02C
-1.03
<TS 1721 A
129 56 20 02H 1.07
<TS 1722 A
129 58 28 02H 0.88
<TS 1723 A
129 58 10 VS2
-0.85
<TS 1724 A
129 74 14 VS1
-0.82
<TS 1725 A
129 84 13 VS4 0.67
<TS 1726 A
129 86 11 DBH 1.78
<TS 1727 A
129 92 13 VS4
-0.82
<TS 1728 A
129 94 12 VS4 0.56
<TS 1729 A
129 94 13 VS4 0.04
<TS 1730 A
129 110 24 02C 0.76
<TS 1731 A
129 110 17 04C
-0.02
<TS 1732 A
129 112 17 VS2
-0.76
<TS 1733 A
130 55 16 02H 0.84
<TS 1734 A
130 57 12 02H 0.93
<TS 1735 A
130 57 21 08H 0.84
<TS 1736 A
130 71 20 VS4
-0.92
<TS 1737 A
130 73 12 VS6 0.98
<TS 1738 A
130 73 16 VS7 0.85
<TS 1739 A
130 89 9
DBC
-1.86
<TS 1740 A
130 93 12 DBH 1.94
<TS 1741 A
130 95 21 VS4
-1.03
<TS 1742 A
130 99 24 03C
-0.2
<TS 1743 A
130 99 9
03C
-0.87
<TS 1744 A
130 107 14 03C
-0.26
<TS 1745 A
130 107 17 02C 0.93
<TS 1746 A
131 70 11 DBC 1.69
<TS 1747 A
131 76 12 06C 0.77
<TS 1748 A
131 94 18 08H 0.95
<TS 1749 A
131 94 14 08H
-0.84
<TS 1750 A
131 94 17 VS1 0.76
<TS 1751 A
131 96 19 06C 0.78
<TS 1752 A
131 106 13 03C
-0.8
<TS 1753 A
132 59 11 01C 0.68
<TS 1754 A
132 63 10 VS6 0.99
<TS 1755 A
132 67 12 VS2 0.85
<TS 1756 A
132 67 18 VS2
-0.89
<TS 1757 A
132 81 13 DBC 1.78
<TS 1758 A
132 87 10 DBH 1.87
<TS 1759 A
132 91 19 DBC
-1.96
<TS 1760 A
132 93 31 VS2 0.59
<TS 1761 A
132 95 34 VS?
0.85
<TS 1762 A
132 97 19 VS?
-0.64
<TS 1763 A
132 97 8
08C
-0.02
<TS 1764 A
132 99 13 DBC 1.7
<TS Page C-34
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1765 A
133 60 12 02H
-0.76
<TS 1766 A
133 60 13 02H 0.96
<TS 1767 A
133 60 13 VS4 0.43
<TS 1768 A
133 64 16 05H
-0.11
<TS 1769 A
133 64 11 VS1 1.01
<TS 1770 A
133 66 13 VS4
-0.71
<TS 1771 A
133 84 14 08H
-0.13
<TS 1772 A
133 86 15 DBC
-1.67
<TS 1773 A
133 88 16 DBC 1.65
<TS 1774 A
133 92 24 VS6 0.89
<TS 1775 A
133 92 17 VS7 0.09
<TS 1776 A
133 94 15 VS2 0.78
<TS 1777 A
133 94 15 VS4
-0.69
<TS 1778 A
133 94 21 VS6
-0.88
<TS 1779 A
133 94 13 VS6 0.93
<TS 1780 A
133 94 11 DBC 1.14
<TS 1781 A
133 94 11 DBC
-1.81
<TS 1782 A
134 65 22 07H
-0.09
<TS 1783 A
134 65 12 08H 0.9
<TS 1784 A
134 65 13 DBH
-1.97
<TS 1785 A
134 65 10 VS1 0.9
<TS 1786 A
134 69 19 VS7 0.3
<TS 1787 A
134 69 28 VS7 0.92
<TS 1788 A
134 69 9
VS6 1.13
<TS 1789 A
134 71 12 VS1
-0.87
<TS 1790 A
134 71 19 VS1
-0.02
<TS 1791 A
134 71 20 VS1 0.87
<TS 1792 A
134 89 10 DBC
-1.71
<TS 1793 A
134 91 35 DBC 1.91
<TS 1794 A
134 91 28 VS7
-0.8
<TS 1795 A
134 91 20 VS6
-0.63
<TS 1796 A
134 91 13 VS6 1.02
<TS 1797 A
134 95 31 VS2 0.02
<TS 1798 A
134 95 28 VS4
-0.93
<TS 1799 A
134 95 16 VS4 0.99
<TS 1800 A
134 95 32 VS6 0.95
<TS 1801 A
134 95 37 VS7 0.75
<TS 1802 A
134 99 16 04C
-0.92
<TS 1803 A
134 103 16 02C
-0.87
<TS 1804 A
134 103 14 DBC
-1.85
<TS 1805 A
135 72 27 VS1
-0.82
<TS 1806 A
135 72 13 VS1 1.01
<TS 1807 A
135 72 13 VS7 0.76
<TS 1808 A
135 76 17 DBC 1.86
<TS 1809 A
135 78 25 08C
-1.12
<TS 1810 A
135 78 39 VS6 0.71
<TS 1811 A
135 78 10 VS4 1.1
<TS 1812 A
135 78 6
VS4 0.3
<TS 1813 A
135 78 15 VS1 0.96
<TS 1814 A
135 82 13 08H 0.98
<TS 1815 A
135 82 11 VS4
-0.78
<TS 1816 A
135 86 17 VS4 1.08
<TS Page C-35
A.
Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1817 A
135 86 16 DBC
-1.81
<TS 1818 A
135 90 21 08C 0.71
<TS 1819 A
135 94 27 DBC
-1.84
<TS 1820 A
135 94 28 VS7
-0.61
<TS 1821 A
135 94 24 VS6 0.93
<TS 1822 A
135 94 16 VS6
-0.71
<TS 1823 A
135 94 13 VS4 0.95
<TS 1824 A
135 100 21 VS6
-0.84
<TS 1825 A
135 100 35 VS7
-0.67
<TS 1826 A
135 100 20 DBC 1.83
<TS 1827.
A 135 100 17 04C
-0.94
<TS 1828 A
135 100 20 02C 0.78
<TS 1829 A
136 69 16 VS7
-0.8
<TS 1830 A
136 69 8
VS7 0.82
<TS 1831 A
136 69 10 DBC 1.44
<TS 1832 A
136 69 13 DBC
-1.67
<TS 1833 A
136 79 8
VS7
-0.85
<TS 1834 A
136 79 10 VS7 0.96
<TS 1835 A
136 79 28 07C
-0.26
<TS 1836 A
136 85 16 08H
-1.03
<TS 1837 A
136 91 9
DBC 1.84
<TS 1838 A
136 91 28 08C 0.71
<TS 1839 A
136 91 22 08C
-0.98
<TS 1840 A
136 91 18 07C
-0.96
<TS 1841 A
136 91 12 05C 0
<TS 1842 A
136 91 12 05C
-1.04
<TS 1843 A
136 91 11 04C
-0.91
<TS 1844 A
136 91 24 06C
-0.85
<TS 1845 A
136 93 13 VS6 0.87
<TS 1846 A
137 74 12 DBH 2.01
<TS 1847 A
137 74 10 VS1
-0.59
<TS 1848 A
137 74 23 VS1 0.14
<TS 1849 A
137 74 20 VS1 0.94
<TS 1850 A
137 76 8
VS2
-0.75
<TS 1851 A
137 76 13 VS2
-0.09
<TS 1852 A
137 76 26 VS4
-0.66
<TS 1853 A
137 76 24 VS4 0
<TS 1854 A
137 76 12 VS6 0.07
<TS 1855 A
137 78 17 VS4
-0.57
<TS 1856 A
137 78 22 VS4 1.08
<TS 1857 A
137 78 13 VS7 0.73
<TS 1858 A
137 80 17 VS6
-0.96
<TS 1859 A
137 80 15 VS7 0.16
<TS 1860 A
137 80 24 VS7 0.78
<TS 1861 A
137 88 15 VS4
-0.5
<TS 1862 A
137 88 12 VS6
-0.67
<TS 1863 A
137 88 16 VS6
-0.04
<TS 1864 A
137 90 16 05H
-0.8
<TS 1865 A
137 90 17 DBC 0.76
<TS 1866 A
137 92 29 05C
-0.07
<TS 1867 A
137 92 21 07C
-0.95
<TS 1868 A
137 92 21 08C
-0.96
<TS Page C-36
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1869 A
137 92 28 08C 0.76
<TS 1870 A
137 92 27 VS6
-0.17
<TS 1871 A
137 92 37 VS6
-0.93
<TS 1872 A
137 92 18 VS6 0.93
<TS 1873 A
138 75 29 DBH 1.97
<TS 1874 A
138 75 14 08C
-0.02
<TS 1875 A
138 75 9
07C 0.72
<TS 1876 A
138 81 8
08H
-0.18
<TS 1877 A
138 81 13 08H 0.89
<TS 1878 A
138 81 29 DBH 2.04
<TS 1879 A
138 81 9
VS1
-0.89
<TS 1880 A
138 81 7
VS1 1.03
<TS 1881 A
138 81 9
VS2
-0.14
<TS 1882 A
138 81 13 VS4
-0.94
<TS 1883 A
138 81 19 VS4 1.05
<TS 1884 A
138 81 33 VS6
-0.87
<TS 1885 A
138 81 27 VS6 0.94
<TS 1886 A
138 81 17 VS7 0.18
<TS 1887 A
138 81 20 VS7 0.83
<TS 1888 A
138 81 17 08C
-1.14
<TS 1889 A
138 83 14 08H
-1.07
<TS 1890 A
138 83 9
08H
-0.09
<TS 1891 A
138 83 27 DBH 2.06
<TS 1892 A
138 83 13 VS1
-0.64
<TS 1893 A
138 85 17 DBC
-1.71
<TS 1894 A
138 85 28 VS7 0.97
<TS 1895 A
138 85 16 VS6 0.84
<TS 1896 A
138 85 15 08H
-0.95
<TS 1897 A
138 89 17 VS1 0.95
<TS Page C-37
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 APPENDIX D: SUPPORT WEAR LISTING - SGB Depth No SG Row Column
(%TW)
Location Elevation Status 1
B 1
28 13 D2C D.8
<TS 2
B 1
36 1S D3C D.78
<TS 3
B 1
124 13 D2C D.79
<TS 4
B 1
1SD 23 D1C
-D.6
<TS s
B 1
1S8 17 D2C D.82
<TS 6
B 1
16D 13 D3C
-D.18
<TS 7
B 1
16D 16 D4H D.8S
<TS 8
B 1
16D 11 D4H
-D.21
<TS 9
B 1
164 19 D2C
-D.97
<TS 1D B
2 11 13 D2C D.84
<TS 11 B
2 141 16 D3H
-D.89
<TS 12 B
2 143 14 D2C D.82
<TS 13 B
2 16S 18 D1C D.8
<TS 14 B
3 2
12 D3H D.74
<TS 1S B
3 6
16 D2C D.88
<TS 16 B
3 6
12 D2C
-1
<TS 17 B
3 36 18 D3C D.72
<TS 18 B
3 42 2D D3C D.74
<TS 19 B
4 16S 1S D2C
-D.98
<TS 2D B
4 16S 13 D2C D.84
<TS 21 B
s 138 14 D2H
-D.9S
<TS 22 B
6 16S 24 D2C
-1.D1
<TS 23 B
7 2
19 DSH 1.17
<TS 24 B
7 14D 1S D4C D.8S
<TS 2S B
8 3
1S D3C
-D.2
<TS 26 B
9 46 18 DBH D.S6
<TS 27 B
9 14D 14 D3C D.8
<TS 28 B
10 133 14 D2C D.86
<TS 29 B
11 2
18 D2H D.9S
<TS 3D B
11 112 12 DBC 1.3S
<TS 31 B
11 164 24 D4C D.73
<TS 32 B
11 164 2S D2C
-D.94
<TS 33 B
12 3
16 D3C
-D.9
<TS 34 B
13 2
14 D4C
-D.36
<TS 3S B
13 4
18 D2H
-D.83
<TS 36 B
13 6
16 D3C D.76
<TS 37 B
13 62 16 DSC
-1
<TS 38 B
13 14D 13 D2H D.8S
<TS 39 B
14 37 12 DBH 2.DS
<TS 4D B
14 S7 19 DBC
-1.1S
<TS 41 B
14 1S9 11 D2H
-D.83
<TS 42 B
1S 13D 2S DSC
-D.9S
<TS 43 B
1S 1S4 19 D4H D.98
<TS 44 B
1S 164 17 D2H D.91
<TS 4S B
16 37 10 DSC
-D.18
<TS 46 B
16 SS 11 DBH
-1.S2
<TS 47 B
17 2
14 D3C D.78
<TS 48 B
17 36 1S D4H
-D.84
<TS Page D-1
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 49 8
18 5
16 03C
-0.18
<TS 50 8
18 137 15 VS4 1.19
<TS 51 8
19 60 11 03H
-0.79
<TS 52 8
19 164 28 02C 0.74
<TS 53 8
21 4
14 03C 0.8
<TS 54 8
21 8
13 03C
-0.96
<TS 55 8
21 58 17 02C 0.85
<TS 56 8
21 64 13 DBC
-1.68
<TS 57 8
22 11 15 02C 0.79
<TS 58 8
22 133 22 VS4 0.98
<TS 59 8
22 163 20 02C 0.84
<TS 60 8
23 106 11 VS4
-0.86
<TS 61 8
24 7
16 DBH 1.78
<TS 62 8
24 53 16 02C 0.87
<TS 63 8
25 6
12 02C
-0.89
<TS 64 8
25 36 10 04H
-0.78
<TS 65 8
25 40 12 04H
-0.75
<TS 66 8
27 64 16 05H 0
<TS 67 8
27 64 19 DBH
-1.68
<TS 68 8
27 64 11 VS4
-0.11
<TS 69 8
28 39 23 VS4 1.08
<TS 70 8
29 120 19 03H 0.88
<TS 71 8
30 5
9 02H
-0.15
<TS 72 8
30 7
12 03C 0.78
<TS 73 8
30 7
8 03C
-0.07
<TS 74 8
30 9
15 02C 0.77
<TS 75 8
30 45 14 VS4 1.05
<TS 76 8
30 51 11 02H 0.86
<TS 77 8
30 53 13 02C 0.83
<TS 78 8
30 57 14 03C
-0.94
<TS 79 8
31 4
15 03C
-0.93
<TS 80 8
31 4
16 02C
-0.87
<TS 81 8
31 4
10 03C 0.07
<TS 82 8
31 14 15 05H
-0.9
<TS 83 8
31 50 16 03C 0.85
<TS 84 8
32 5
13 04H 0.84
<TS 85 8
32 5
15 02C 0.72
<TS 86 8
32 13 16 03C 0.74
<TS 87 8
32 45 10 02H 0.94
<TS 88 8
32 45 11 03H 0.96
<TS 89 8
32 109 11.
04C 0.65
<TS 90 8
32 151 12 VS4 0.97
<TS 91 8
32 157 17 DBH 1.52
<TS 92 8
33 4
15 01C
-0.9
<TS 93 8
33 12 17 VS4 0.94
<TS 94 8
33 32 13 04H 0.97
<TS 95 8
33 52 12 03C 0.79
<TS 96 8
33 54 11 03C
-0.94
<TS 97 8
33 158 20 02C 0.74
<TS 98 8
33 160 14 02C
-1
<TS 99 8
33 162 16 03C 0.89
<TS 100 8
33 162 16 02C
-1.04
<TS Page D-2
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 101 B
34 11 12 VS4 1
<TS 102 B
34 11 15 DBC
-1.55
<TS 103 B
34 31 22 VS4 0.24
<TS 104 B
34 43 10 03H 0.96
<TS 105 B
34 47 10 03H
-0.85
<TS 106 B
34 59 11 03H
-0.82
<TS 107 B
34 103 17 04H
-0.94
<TS 108 B
34 113 15 01C 0.77
<TS 109 B
34 117 14 04C 0.74
<TS 110 B
34 133 20 03C 0.77
<TS 111 B
34 161 17 02C 0.74
<TS 112 B
35 4
30 DBC 1.91
<TS 113 B
35 4
14 DBC
-0.26
<TS 114 B
35 4
17 01C
-0.93
<TS 115 B
35 6
13 05C
-0.24
<TS 116 B
35 36 21 VS4 0.77
<TS 117 B
35 36 14 03H 0.9
<TS 118 B
35 42 17 05H 1.02
<TS 119 B
35 46 11 03H
-0.9
<TS 120 B
35 46 12 03H 0.83
<TS 121 B
35 46 13 03C 0.76
<TS 122 B
35 52 19 05C 0.81
<TS 123 B
35 52 21 DBC 1.25
<TS 124 B
35 56 15 03H
-0.77
<TS 125 B
35 64 16 05H 0.99
<TS 126 B
36 5
20 03C 0.7
<TS 127 B
36 5
11 03C
-0.04
<TS 128 B
36 41 14 03H
-0.83
<TS 129 B
36 45 23 VS4
-0.78
<TS 130 B
36 49 12 04H 0.84
<TS 131 B
36 51 14 VS4 0.83
<TS 132 B
36 51 8
VS4
-0.7
<TS 133 B
36 109 14 04C 0.83
<TS 134 B
36 113 15 03C 0.78
<TS 135 B
36 119 12 03C
-0.85
<TS 136 B
36 149 19 VS4
-0.84
<TS 137 B
36 149 14 VS4 0.33
<TS 138 B
36 157 18 02C
-0.89
<TS 139 B
36 161 16 02H 0.98
<TS 140 B
36 161 15 04C
-0.19
<TS 141 B
37 6
15 01H
-0.81
<TS 142 B
37 6
20 03H 0.76
<TS 143 B
37 6
16 02C
-0.17
<TS 144 B
37 6
16 02C
-0.98
<TS 145 B
37 10 22 03C
-0.96
<TS 146 B
37 32 12 03H 0.86
<TS 147 B
37 36 12 03H
-0.9
<TS 148 B
37 48 16 02H
-0.75
<TS 149 B
37 50 13 02H
-0.85
<TS 150 B
37 54 16 02H 0.98
<TS 151 B
37 54 13 04C 0.85
<TS 152 B
37 122 25 VS4
-0.83
. <TS Page D-3
-~~~--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 153 B
37 124 15 VS4
-0.85
<TS 154 B
37 124 22 VS4 0.93
<TS 155 B
37 128 18 VS4
-0.76
<TS 156 B
37 128 21 VS4 1
<TS 157 B
37 148 28 VS4
-0.72
<TS 158 B
37 156 21 VS4
-0.97
<TS 159 B
37 156 26 VS4 0.94
<TS 160
- s.
37 160 18 02H 0.97
<TS 161 B
37 160 18 VS4
-0.37
<TS 162 B
37 160 23 VS4 1.1
<TS 163 B
38 5
16 02C
-0.91
<TS 164 B
38 9
14 03C
-1.05
<TS 165 B
38 13 20 VS4 0.7
<TS 166 B
38 39 16 02H 0.94
<TS 167 B
38 45 15 02C 0.09
<TS 168 B
38 49 29 VS4 0.8
<TS 169 B
38 49 11 02H
-0.86
<TS 170 B
38 49 19 VS4 0:18
<TS 171 B
38 51 13 VS4
-0.62
<TS 172 B
38 51 11 02C 0.83
<TS 173 B
38 53 13 03H
-0.81
<TS 174 B
38 53 21 VS4 0.04
<TS 175 B
38 53 18 VS4 0.69
<TS 176 B
38 107 20 02C 0.76
<TS 177 B
38 115 13 04C 0.78
<TS 178 B
38 125 21 VS4
-0.82
<TS 179 B
38 125 36 VS4 0.86
<TS 180 B
38 125 9
VS4
-0.02
<TS 181 B
38 127 24 VS4 0.87
<TS 182 B
38 127 15 02C
-0.96
<TS 183 B
38 127 11 04C 0.04
<TS 184 B
38 131 18 VS4 0.91
<TS 185 B
38 133 17 VS4
-0.78
<TS 186 B
38 145 23 VS4 1.14
<TS 187 B
38 147 33 VS4
-0.76
<TS 188 B
38 147 15 VS4 1.14
<TS 189 B
38 161 23 02H 0.89
<TS 190 B
39 6
15 02C
-0.2
<TS 191 B
39 6
11 02C 0.83
<TS 192 B
39 8
13 03C 0.77
<TS 193 B
39 8
15 03C
-0.98
<TS 194 B
39 10 12 03C 0.7
<TS 195 B
39 12 20 VS4
-0.46
<TS 196 B
39 22 14 DBC 1.52
<TS 197 B
39 50 11 VS4
-0.46
<TS 198 B
39 52 13 03H
-0.8
<TS 199 B
39 102 18 VS4
-0.68
<TS 200 B
39 108 13 DBH
-1.75
<TS 201 B
39 116 16 VS4
-0.77
<TS 202 B
39 116 35 VS4 0.93
<TS 203 B
39 120 25 VS4 0.91
<TS 204 B
39 122 28 VS4 0.8
<TS Page D-4
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 205 B
39 122 13 02C
-0.96
<TS 206 B
39 134 25 VS4
-0.84
<TS 207 B
39 146 18 DBC 1.56
<TS 208 B
39 160 18 02H 0.88
<TS 209 B
40 5
17 02C
-0.94
<TS 210 B
40 31 13 03H 0.94
<TS 211 B
40 31 15 VS4 0.89
<TS 212 B
40 33 13 VS4 0.72
<TS 213 B
40 39 13 04H
-0.81
<TS 214 B
40 51 14 01H 0.92
<TS 215 B
40 55 12 03H
-0.82
<TS 216 B
40 115 12 03C 0.76
<TS 217 B
40 115 12 04C 0.74
<TS 218 B
40 117 18 03C 0.82
<TS 219 B
40 121 21 VS4
-0.8
<TS 220 B
40 121 28 VS4 1.04
<TS 221 B
40 123 19 VS4 1.02
<TS 222 B
40 123 13 03C
-1.02
<TS 223 B
40 125 20 02C
-0.92
<TS 224 B
40 129 17 04C
-0.8
<TS 225 B
40 143 18 05H 0.9
<TS 226 B
41 6
13 01C 0.74
<TS 227 B
41 6
13 01C
-1.05
<TS 228 B
41 8
20 04C 0.76
<TS 229 B
41 12 22 VS4 0.78
<TS 230 B
41 12 19 05C
-0.07
<TS 231 B
41 12 27 VS4 0.02
<TS 232 B
41 14 32 VS4 0.22
<TS 233 B
41 14 12 VS4 0.78
<TS 234 B
41 28 16 05H 0.96
<TS 235 B
41 32 23 VS4 0.07
<TS 236 B
41 32 7
VS4 0.67
<TS 237 B
41 36 13 03H
-0.49
<TS 238 B
41 40 9
02C
-0.24
<TS 239 B
41 48 12 VS4
-0.85
<TS 240 B
41 48 15 03H 0.92
<TS 241 B
41 54 18 VS4
-0.84
<TS 242 B
41 54 34 VS4 0.8
<TS 243 B
41 56 12 02H 0.89
<TS 244 B
41 120 7
05C 0.83
<TS 245 B
41 122 19 VS4
-0.91
<TS 246 B
41 122 12 VS4 0.65
<TS 247 B
41 128 15 04C
-0.99
<TS 248 B
41 132 17 VS4 0.89
<TS 249 B
41 132 18 04C 0.26
<TS 250 B
41 134 15 03C 0.75
<TS 251 B
42 27 21 VS4
-0.73
<TS 252 B
42 37 17 VS4
-0.02
<TS 253 B
42 39 18 VS4 0.18
<TS 254 B
42 41 37 VS4 0.85
<TS 255 B
42 41 30 VS4 0.22
<TS 256 B
42 47 13 03H
-0.79
<TS Page D-5
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 257 B
42 51 37 VS4
-0.73
<TS 258 B
42 51 14 VS4
-0.18
<TS 259 B
42 51 25 VS4 0.93
<TS 260 B
42 57 38 VS4 0.75
<TS 261 B
42 57 20 VS4 0.2.
<TS 262 B
42 123 33 VS4 0.93
<TS 263 B
42 133 15 02H
-0.85
<TS 264 B
43 6
10 05H
-0.17
<TS 265 B
43 6
26 02C
-0.17
<TS 266 B
43 6
12 02C
-0.89
<TS 267 B
43 8
13 03C 0.72
<TS 268 B
43 42 14 05C 0.76
<TS 269 B
43 48 20 05C 0.8
<TS 270 B
43 126 19 04C
-0.92
<TS 271 B
43 132 17 VS4 0.87
<TS 272 B
43 134 15 03C
-1.04
<TS 273 B
44 19 13 VS4 0.27
<TS 274 B
44 21 23 VS4
-0.78
<TS 275 B
44 21 28 VS4 0.86
<TS 276 B
44 23 28 DBH
-1.64
<TS 277 B
44 23 14 VS4 0.87
<TS 278 B
44 27 26 VS4
-0.67
<TS 279 B
44 27 27 VS4 1.06
<TS 280 B
44 27 12 DBC
-1.46
<TS 281 B
44 29 14 VS4 0.7
<TS 282 B
44 29 32 VS4 0.07
<TS 283 B
44 29 17 VS4
-0.84
<TS 284 B
44 31 37 VS4
-0.58
<TS 285 B
44 31 21 VS4 0.11
<TS 286 B
44 31 20 DBC 1.37
<TS 287 B
44 31 18 02C 0.75
<TS 288 B
44 33 11 VS4 0.22
<TS 289 B
44 33 9
VS4 0.93
<TS 290 B
44 37 33 VS4 0.11
<TS 291 B
44 37 19 VS4 0.86
<TS 292 B
44 41 16 02C
-0.28
<TS 293 B
44 45 24 VS4 1
<TS 294 B
44 45 18 04C 0.79
<TS 295 B
44 45 15 03C 0.76
<TS 296 B
44 47 22 VS4
-0.58
<TS 297 B
44 47 22 VS4 0.2
<TS 298 B
44 53 10 VS4
-0.57
<TS 299 B
44 57 21 VS4
-0.69
<TS 300 B
44 57 13 VS4 0.13
<TS 301 B
44 59 14 VS4 0.83
<TS 302 B
44 59 25 VS4 0.06
<TS 303 B
44 63 11 VS4
-0.77
<TS 304 B
44 63 21 VS4 0.99
<TS 305 B
44 65 24 VS4 0
<TS 306 B
44 65 22 VS4 0.97
<TS 307 B
44 99 17 DBH 1.71
<TS 308 B
44 101 16 04C 0.79
<TS Page D-6
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 309 B
44 103 33 VS4 0.96
<TS 310 B
44 107 25 VS4 0.98
<TS 311 B
44 107 19 VS4
-0.72
<TS 312 B
44 121 11 03C 0.78
<TS 313 B
44 127 21 02C 0.81
<TS 314 B
44 131 13 VS4 0.94
<TS 315 B
44 131 19 03C 0.8
<TS 316 B
44 137 13 04C
-0.96
<TS 317 B
44 159 16 01H
-0.92
<TS 318 B
45 6
24 02C
-0.22
<TS 319 B
45 6
28 02C
-0.96
<TS 320 B
45 16 10 DBH
-1.57
<TS 321 B
45 32 23 VS4
-0.69
<TS 322 B
45 32 23 VS4 0.35
<TS 323 B
45 32 22 VS4 1.02
<TS 324 B
45 34 20 VS4
-0.73
<TS 325 B
45 34 32 VS4 0.11
<TS 326 B
45 34 13 VS4 0.77
<TS 327 B
45 36 27 VS4 0.2
<TS 328 B
45 36 18 VS4 1.12
<TS 329 B
45 38 10 VS4
-0.49
<TS 330 B
45 38 12 VS4 0.38
<TS 331 B
45 42 24 VS4
-0.82
<TS 332 B
45 42 16 VS4 0.95
<TS 333 B
45 48 21 VS4 0.83
<TS 334 B
45 48 22 VS4 0.22
<TS 335 B
45 48 16 VS4
-0.76
<TS 336 B
45 56 13 03H 0.9
<TS 337 B
45 64 15 DBC
-1.86
<TS 338 B
45 66 14 VS4 0.67
<TS 339 B
45 66 19 VS4 0.02
<TS 340 B
45 108 11 03H 0.11
<TS 341 B
45 114 13 03C
'0.77
<TS 342 B
45 118 18 06H
-0.2
<TS 343 B
45 122 26 VS4
-0.8
<TS 344 B
45 122 32 VS4 1
<TS 345 B
45 126 18 02C 0.74
<TS 346 B
45 128 14 03H
-0.89
<TS 347 B
45 130 16 VS4 1.09
<TS 348 B
45 132 15 VS4 0.88
<TS 349 B
45 140 16 VS4
-0.87
<TS 350 B
45 140 31 VS4 0.8
<TS 351 B
45 140 13 06C
-0.57
<TS 352 B
45 140 18 DBH
-1.48
<TS 353 B
45 148 19 VS4 1.05
<TS 354 B
45 148 16 06C
-0.88
<TS 355 B
46 7
8 01C 0.72
<TS 356 B
46 7
23 01C
-0.31
<TS 357 B
46 7
17 06C 1.19
<TS 358 B
46 21 11 VS4 0.93
<TS 359 B
46 23 19 VS4
-0.98
<TS 360 B
46 23 23 VS4 0.84
<TS Page D-7
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 361 B
46 25 11 VS4
-0.63
<TS 362 B
46 33 13 DBC
-1.68
<TS 363 B
46 33 12 VS4 0
<TS 364 B
46 33 26 VS4
-0.86
<TS 365 B
46 35 22 VS4
-0.79
<TS 366 B
46 37 14 DBC
-1.63
<TS 367 B
46 37 20 VS4 0.88
<TS 368 B
46 37 15 VS4
-0.88
<TS 369 B
46 39 22 VS4 0.11
<TS 370 B
46 39 25 VS4 0.89
<TS 371 B
46 47 12 02H
-0.06
<TS 372 B
46 59 13 03C 0.82
<TS 373 B
46 69 14 DBH
-1.83
<TS 374 B
46 103 16 04C 0.83
<TS 375 B
46 125 14 02C
-0.96
<TS 376 B
46 129 22 VS4 0.72
<TS 377 B
46 129 13 03C 0.77
<TS 378 B
46 131 16 VS4
-0.86
<TS 379 B
46 131 12 VS4 0.2
<TS 380 B
46 143 13 DBC 1.27
<TS 381 B
46 151 35 VS4 0.92
<TS 382 B
47 8
9 01H 0.92
<TS 383 B
47 12 18 VS4
-0.75
<TS 384 B
47 12 25 VS4 1.1
<TS 385 B
47 14 25 VS4
-0.02
<TS 386 B
47 14 25 VS4 0.66
<TS 387 B
47 20 28 VS4
-0.8
<TS 388 B
47 20 30 VS4 0.97
<TS 389 B
47 22 18 VS4
-0.75
<TS 390 B
47 22 17 VS4 1.04
<TS 391 B
47 34 14 VS4 0.95
<TS 392 B
47 46 20 VS4
-0.61
<TS 393 B
47 46 22 VS4 0.11
<TS 394 B
47 46 12 VS4 0.95
<TS 395 B
47 56 30 VS4 1.06
<TS 396 B
47 56 18 VS4
-0.71
<TS 397 B
47 58 21 VS4 0.82
<TS 398 B
47 70 19 VS4
-0.63
<TS 399 B
47 96 16 VS4
-0.83
<TS 400 B
47 96 22 VS4 0.94
<TS 401 B
47 98 22 VS4 0.95
<TS 402 B
47 102 12 VS4
-0.9
<TS 403 B
47 108 27 06H 0.96
<TS 404 B
47 108 23 VS4
-0.96
<TS 405 B
47 108 21 VS4 0
<TS 406 B
47 108 26 VS4 0.96
<TS 407 B
47 114 15 06C 0.87
<TS 408 B
47 116 16 04C
-0.98
<TS 409 B
47 126 32 VS4
-0.77
<TS 410 B
47 126 32 VS4 1.1
<TS 411 B
47 128 26 VS4
-0.79
<TS 412 B
47 132 14 VS4
-0.81
<TS Page D-8
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 413 B
47 132 14 VS4 0.91
<TS 414 B
47 140 15 VS4 1.07
<TS 415 B
47 148 17 04C 0.89
<TS 416 B
48 7
12 01H 0.96
<TS 417 B
48 9
32 VS4
-0.65
<TS 418 B
48 9
30 VS4 0.31
<TS 419 B
48 9
20 VS4 0.92
<TS 420 B
48 13 23 VS4
-0.7
<TS 421 B
48 13 31 VS4 0.25
<TS 422 B
48 13 22 VS4 0.92
<TS 423 B
48 13 19 VS4
-0.11
<TS 424 B
48 65 27 VS4
-0.65
<TS 425 B
48 67 10 VS4 0.89
<TS 426 B
48 67 14 VS4 0.22
<TS 427 B
48 99 14 03C 0.79
<TS 428 B
48 107 17 04C 0.76
<TS 429 B
48 111 17 04C 0.81
<TS 430 B
48 123 14 VS4 0.87
<TS 431 B
48 125 16 03C 0.83
<TS 432 B
48 129 13 03C
-0.17
<TS 433 B
48 139 15 03H 1.02
<TS 434 B
48 159 11 01H
-0.96
<TS 435 B
49 8
24 VS4 0.89
<TS 436 B
49 10 22 01C 0.77
<TS 437 B
49 12 9
DBC 1.57
<TS 438 B
49 26 12 03H 0.92
<TS 439 B
49 34 13 VS4
-0.9
<TS 440 B
49 34 39 VS4 0.81
<TS 441 B
49 46 20 VS4
-0.63
<TS 442 B
49 56 11 03H
-0.89
<TS 443 B
49 74 24 DBH
-1.63
<TS 444 B
49 106 17 VS4 0.04
<TS 445 B
49 122 14 04C 0.76
<TS 446 B
49 124 22 VS4
-0.78
<TS 447 B
49 132 16 03C
-0.94
<TS 448 B
49 144 10 02H 0.78
<TS 449 B
49 158 18 01C 0.02
<TS 450 B
50 7
17 DBH 1.79
<TS 451 B
50 9
13 01C
-0.~7
<TS 452 B
50 63 15 DBH
-1.54
<TS 453 B
50 127 14 03C
-0.94
<TS 454 B
50 157 21 01H
-0.91
<TS 455 B
50 159 17 01C 0.81
<TS 456 B
51 36 13 03C
-0.96
<TS 457 B
51 36 11 03C 0.79
<TS 458 B
51 58 13 01H 0.88
<TS 459 B
51 58 13 03H 0.83
<TS 460 B
51 64 18 02C 0.91
<TS 461 B
51 72 12 VS3
-0.89
<TS 462 B
51 116 21 VS3
-0.94
<TS 463 B
51 134 15 03C
-0.95
<TS 464 B
51 156 25 VS5
-0.76
<TS Page D-9
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 465 B
52 25 15 02H 0.85
<TS 466 B
52 65 14 03C 0.78
<TS 467 B
52 107 16 02C 0.87
<TS 468 B
53 8
15 01C 0.7
<TS 469 B
53 56 13 03H 0.88
<TS 470 B
53 60 14 04H 1.03
<TS 471 B
53 80 17 03C 0.77
<TS 472 B
53 118 14 02C
-0.17
<TS 473 B
53 120 12 04C 0.81
<TS 474 B
53 128 17 03C 0.72
<TS 475 B
53 132 19 02C 0.78
<TS 476 B
53 134 14 03C 0.83
<TS 477 B
54 17 13 VS3
-0.83
<TS 478 B
54 17 14 VS3 1.04
<TS 479 B
54 71 14 02H 0.93
<TS 480 B
54 103 19 VS3
-0.67
<TS 481 B
54 117 16 02C 0.8
<TS 482 B
54 143 13 VS3
-0.77
<TS 483 B
55 32 16 VS3
-0.61
<TS 484 B
55 54 14 VS3
-0.87
<TS 485 B
55 56 12 03H 1.09
<TS 486 B
55 60 14 04H 0.88
<TS 487 B
55 64 16 02C 0.82
<TS 488 B
55 78 15 01C 0.82
<TS 489 B
55 96 12 01C 0.85
<TS 490 B
55 114 17 03C 0.78
<TS 491 B
55 120 15 04H
-0.86
<TS 492 B
55 126 11 03C 0.04
<TS 493 B
56 55 14 VS4
-0.65
<TS 494 B
56 59 11 04H 0.96
<TS 495 B
56 77 11 02C 0.71
<TS 496 B
56 85 17 02C
-0.98
<TS 497 B
56 85 24 03C 0.87
<TS 498 B
56 97 19 04C 0.85
<TS 499 B
56 129 15 VS3 0.9
<TS 500 B
56 129 20 03C 0.84
<TS 501 B
56 145 13 04C
-0.93
<TS 502 B
57 16 17 06H
-0.06
<TS 503 B
57 26 17 06H 0.92
<TS 504 B
57 62 17 04H 0.91
<TS 505 B
57 80 13 03C 0.73
<TS 506 B
57 90 14 03C
-1
<TS 507 B
57 90 22 03C 0.81
<TS 508 B
57 120 11 04C
-0.18
<TS 509 B
57 142 13 VS3 0.94
<TS 510 B
57 142 15 04C 0.67
<TS 511 B
57 144 13 04C 0.78
<TS 512 B
57 146 9
DBH 1.63
<TS 513 B
57 148 13 04C 0.8
<TS 514 B
58 25 9
06H 0.94
<TS 515 B
58 27 14 05H 0.99
<TS 516 B
58 47 11 03C
-0.99
<TS Page D-10
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 517 8
58 57 15 06C 0.72
<TS 518 8
58 59 11 02H
-0.09
<TS 519 8
58 63 14 04H 0.85
<TS 520 8
58 117 15 06C 0.68
<TS 521 8
59 26 14 04H 0.86
<TS 522 8
59 26 13 03C 0.7
<TS 523 8
59 28 17 DBH 1.67
<TS 524 8
59 48 13 06H 1.07
<TS 525 8
59 48 21 03C 0.83
<TS 526 8
59 66 13 02H
-0.81
<TS 527 8
59 70 13 03H
-0.81
<TS 528 8
59 88 14 03C 0.85
<TS 529 8
59 116 16 03C 0.76
<TS 530 8
59 118 17 03C
-0.89
<TS 531 8
59 120 16 04H
-0.81
<TS 532 8
59 120 10 03C
-0.87
<TS 533 8
59 122 13 03C
-0.15
<TS 534 8
60 41 23 02H
-0.04
<TS 535 8
60 119 15 03C 0.76
<TS 536 8
60 133 18 03C
-0.89
<TS 537 8
61 12 15 06H
-0.13
<TS 538 8
61 28 17 DBC 2
<TS 539 8
61 28 12 04H
-0.84
<TS 540 8
61 42 15 VS3 0.74
<TS 541 8
61 48 8
VS3
-1.03
<TS 542 8
61 62 12 03H
-0.78
<TS 543 8
61 68 12 02H
-0.78
<TS 544 8
61 102 15 05C
-0.26
<TS 545 8
61 120 21 02C
-0.91
<TS 546 8
61 124 18 02C 0.8
<TS 547 8
61 142 17 03C 0.86
<TS 548 8
62 17 15 VS4
-0.59
<TS 549 8
62 17 13 VS5 1
<TS 550
- 8 62 23 11 VS5 0.97
<TS 551 8
62 39 7
04H
-0.15
<TS 552 8
62 47 10 DBC
-1.53
<TS 553 8
62 47 9
03C 0.73
<TS 554 8
62 53 9
06H 0.94
<TS 555 8
62 57 12 02H
-0.8
<TS 556 8
62 57 8
02C 0.74
.<TS 557 8
62 59 11 02C 0.74
<TS 558 8
62 85 12 DBC
-1.8
<TS 559 8
62 107 13 02C
-0.91
<TS 560 8
62 111 16 03H 0.19
<TS 561 8
62 155 11 01H
-0.79
<TS 562 8
62 155 14 01H
-0.06
<TS 563 8
62 155 12 01H 0.98
<TS 564 8
63 18 13 DBC
-0.57
<TS 565 8
63 28 9
06H
-0.87
<TS 566 8
63 56 15 03H
-0.76
<TS 567 8
63 56 15 04H
-0.91
<TS 568 8
63 56 17 03C 0.83
<TS Page D-11
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 569 B
63 58 12 04H
-0.84
<TS 570 B
63 60 9
03C
-1.01
<TS 571 B
63 70 18 04H 0.98
<TS 572 B
63 78 9
03H
-0.89
<TS 573 B
63 82 28 VS4 1.03
<TS 574 B
63 82 13 VS5
-0.09
<TS 575 B
63 82 27 VS5 1.14
<TS 576 B
63 110 14 03H
-0.13
<TS 577 B
63 126 14 VS3 0.97
<TS 578 B
63 128 17 06C 0.77
<TS 579 B
63 136 18 VS5 1.01
<TS 580 B
63 136 16 03C 0.79
<TS 581 B
63 138 15 03C 0.77
<TS 582 B
63 140 14 06C
-0.22
<TS 583 B
63 140 22 03C 0.81
<TS 584 B
64 37 18 06H
-0.11
<TS 585 B
64 51 19 VS5
-0.04
<TS 586 B
64 51 16 VS5 0.8
<TS 587 B
64 103 10 04C 0.84
<TS 588 B
64 147 22 DBH 1.95
<TS 589 B
65 16 16 VS3
-0.73
<TS 590 B
65 16 13 06H
-0.22
<TS 591 B
65 32 12 VS3
-0.86
<TS 592 B
65 62 18 04H
-1.19
<TS 593 B
65 110 23 03H 0.94
<TS 594 B
65 118 16 02C 0.78
<TS 595 B
65 122 16 06C 0.85
<TS 596 B
65 122 16 02C 0.8
<TS 597 B
65 130 12 03C 0.85
<TS 598 B
66 17 13 06H 0.92
<TS 599 B
66 21 19 06H 0.83
<TS 600 B
66 27 8
06H
-0.76
<TS 601 B
66 27 9
06C 0.77
<TS 602 B
66 29 13 06C
-0.95
<TS 603 B
66 31 9
06C 0.83
<TS 604 B
66 35 18 06C 0.78
<TS 605 B
66 39 14 VS5
-0.81
<TS 606 B
66 41 12 VS3
-0.7
<TS 607 B
66 41 11 VS3
-0.18
<TS 608 B
66 41 12 VS4
-0.72
<TS 609 B
66 41 9
DBC
-1.77
<TS 610 B
66 45 11 06C 0.72
<TS 611 B
66 47 9
06C
-0.2
<TS 612 B
66 51 11 06H 1.01
<TS 613 B
66 51 10 06C 0.83
<TS 614 B
66 51 9
04C
-0.33
<TS 615 B
66 77 9
VS3
-0.76
<TS 616 B
66 97 12 01C 0.74
<TS 617 B
66 107 16 02H
-0.84
<TS 618 B
66 107 14 02C
-0.98
<TS 619 B
66 125 15 02C 0.81
<TS 620 B
66 137 13 03C 0.81
<TS Page D-12
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 621 B
66 143 14 VS5 0.89
<TS 622 B
66 149 14 06H 0.91
<TS 623 B
66 153 18 VS3 0.66
<TS 624 B
67 36 15 06H 0.95
<TS 625 B
67 46 12 DBC 1.86
<TS 626 B
67 56 11 02H 0.97
<TS 627 B
67 56 14 04H
-0.85
<TS 628 B
67 56 16 03C 0.77
<TS 629 B
67 56 14 02C 0.83
<TS 630 B
67 58 19 03C 0.81
<TS 631 B
67 62 20 03C 0.74
<TS 632 B
67 62 16 02C
-0.2
<TS 633 B
67 74 13 04H
-0.82
<TS 634 B
67 76 15 02H
-0.78
<TS 635 B
67 104 12 03H 1
<TS 636 B
67 104 7
04H 0.94
<TS 637 B
67 104 21 06C
-0.24
<TS 638 B
67 108 13 03H 0.96
<TS 639 B
67 128 23 VS3 1.01
<TS 640 B
67 128 15 06H 0.26
<TS 641 B
67 134 28 06C
-1.03
<TS 642 B
67 134 16 03C 0.74
<TS 643 B
67 136 23 DBH
-1.8
<TS 644 B
67 138 28 VS3 0.3
<TS 645 B
67 138 28 03C 0.46
<TS 646 B
67 148 23 DBH 1.75
<TS 647 B
67 148 14 VS3 1.03
<TS 648 B
67 150 18 VS3
-0.53
<TS 649 B
67 150 22 VS3 1.07
<TS 650 B
68 17 15 04H 0.84
<TS 651 B
68 21 17 VS5
-0.78
<TS 652 B
68 41 20 04H 0.93
<TS 653 B
68 45 13 DBC
-1.56
<TS 654 B
68 85 12 02C
-0.85
<TS 655 B
68 93 21 04C
-0.96
<TS 656 B
68 93 16 04C
-0.18
<TS 657 B
68 109 19 02H 0.9
<TS 658 B
68 113 22 04H 0.95
<TS 659 B
68 113 11 04H
-0.8
<TS 660 B
68 113 15 03H 0.86
<TS 661 B
68 143 19 06H 0.92
<TS 662 B
68 151 22 VS3
-0.34
<TS 663 B
69 16 17 VS3
-0.67
<TS 664 B
69 28 17 06C 0.89
<TS 665 B
69 28 13 06H
-0.15
<TS 666 B
69 28 14 06H
-0.93
<TS 667 B
69 34 19 DBC 1.29
<TS 668 B
69 36 8
DBC 1.73
<TS 669 B
69 36 9
04C 0.81
<TS 670 B
69 48 8
04C 0
<TS 671 B
69 52 18 VS3 0.07
<TS 672 B
69 52 20 VS4
-0.63
<TS Page D-13
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 673 B
69 52 12 VS4
-0.04
<TS 674 8
69 52 14 VS5
-0.85
<TS 675 8
69 52 15 VS5 0.92
<TS 676 B
69 56 11 VS5
-0.74
<TS 677 B
69 56 14 VS5 0.98
<TS 678 8
69 72 11 03H 0.88
<TS 679 B
69 72 16 06C
-1
<TS 680 B
69 102 10 03H 0.96
<TS 681 B
69 106 16 06H
-0.73
<TS 682 B
69 110.
16 03C 0.74
<TS 683 B
69 120 20 03C 0.78
<TS 684 B
69 120 14 03C 0.02
<TS 685 B
69 124 17 03C
-0.87
<TS 686 B
69 128 16 03C 0.8
<TS 687 B
69 132 14 04H 0.92
<TS 688 B
69 134 13 VS3
-0.7
<TS 689 B
69 134 33 VS4
-0.91
<TS 690 B
69 134 28 VS4 1.09
<TS 691 B
69 134 13 VS5
-0.8
<TS 692 B
69 136 22 VS5
-0.7
<TS 693 B
69 136 13 VS5 1.02
<TS 694 B
69 140 12 VS3 1.11
<TS 695 8
69 140 12 VS4 0.96
<TS 696 B
69 140 23 VS5
-0.78
<TS 697 B
69 144 20 VS3
-0.69
<TS 698 8
69 144 28 VS5
-0.8
<TS 699 B
69 150 30 VS3
-0.59
<TS 700 B
69 150 19 VS3 1.06
<TS 701 B
69 150 18 VS5 0.89
<TS 702 8
70 31 9
06C 0.79
<TS 703 8
70 45 12 03H 0.91
<TS 704 B
70 47 9
04C
-0.24
<TS 705 B
70 51 12 03C 0.79
<TS 706 8
70 75 16 03H
-0.07
<TS 707 B
70 83 14 02C 0.76
<TS 708 B
70 107 15 02H
-0.82
<TS 709 8
70 129 21 06C
-0.98
<TS 710 B
70 141 20 VS3
-0.85
<TS 711 8
70 143 22 DBC 1.17
<TS 712 8
70 147 16 VS3
-0.79
<TS 713 B
70 153 18 VS4 1.07
<TS 714 B
70 153 16 VS4
-0.75
<TS 715 B
70 153 22 03C 0
<TS 716 8
71 14 16 02H
-0.8
<TS 717 B
71 20 17 DBH
-1.73
<TS 718 B
71 20 15 VS5 0.9
<TS 719 8
71 20 13 DBC 1.43
<TS 720 8
71 36 19 VS3 0.07
<TS 721 B
71 36 22 VS3 0.78
<TS 722 B
71 36 16 VS5
-0.67
<TS 723 8
71 36 28 VS5 0.02
<TS 724 B
71 36 10 DBC 1.93
<TS Page D-14
A Document No.: 51-9252894-001
.AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 725 B
71 36 12 DBC
-1.84
<TS 726 B
71 36 12 06C 0.74
<TS 727 B
71 38 14 05H 1
<TS 728 B
71 42 9
04H
-0.81
<TS 729 B
71 46 7
04H
-0.76
<TS 730 B
71 52 17 03C 0.81
<TS 731 B
71 52 10 02C
-0.96
<TS 732 B
71 58 12 02C
-0.18
<TS 733 B
71 62 14 03C
-0.19
<TS 734 B
71 80 15 03C 0.16
<TS 735 B
71 86 18 VS5
-0.76
<TS 736 B
71 86 12 02C
-0.24
<TS 737 B
71 86 17 02C
-0.96
<TS 738 B
71 102 16 05C 0.83
<TS 739 B
71 104 9
02H 0.83
<TS 740 B
71 110 11 04H
-0.84
<TS 741 B
71 112 15 04C 0.76
<TS 742 B
71 132 15 VS5 1.01
<TS 743 B
71 136 12 06C
-0.11
<TS 744 B
71 136 21 06C
-0.92
<TS 745 B
71 142 18 DBC 1.26
<TS 746 B
71 144 32 VS3
-0.79
<TS 747 B
71 144 24 DBC 1.91
<TS 748 B
71 144 21 VS3 0.99
<TS 749 B
71 146 15 06H 0.28
<TS 750 B
71 146 32 VS5
-0.79
<TS 751 B
72 17 23 DBH 1.51
<TS 752 B
72 19 15 VS3 0.22
<TS 753 B
72 23 17 VS3 0.78
<TS 754 B
72 25 24 VS3
-0.81
<TS 755 B
72 25 10 DBC 1.87
<TS 756 B
72 41 25 06C 0.78
<TS 757 B
72 47 15 03C
-0.99
<TS 758 B
72 49 31 03C 0.83
<TS 759 B
72 55 18 VS3
-0.85
<TS 760 B
72 57 13 03C
-0.94
<TS 761 B
72 59 16 04C 0.77
<TS 762 B
72 61 15 02C 0.75
<TS 763 B
72 63 14 02C 0.77
<TS 764 B
72 85 15 05C 0.81
<TS 765 B
72 113 15 04C 0.81
<TS 766 B
72 113 13 04H 0.95
<TS 767 B
72 113 9
02H 0.94
<TS 768 B
72 113 15 02H
-0.8
<TS 769 B
72 125 26 06C 0.87
<TS 770 B
72 149 31 DBH 1.67
<TS 771 B
72 149 19 VS3 0.9
<TS 772 B
73 14 9
VS4
-1.03
<TS 773 B
73 14 9
VS4 0.26
<TS 774 B
73 20 14 VS5 0.87
<TS 775 B
73 40 11 05H 1
<TS 776 B
73 58 17 06C
-0.24
<TS Page D-15
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 777 S
73 58 14 02C
-0.15
<TS 778 S
73 86 13 02C
-0.95
<TS 779 S
73 104 19 06C
-0.98
<TS 780 S
73 106 13 03H 0.97
<TS 781 S
73 132 12 06H 0.96
<TS 782 S
74 17 23 VS3
-0.7
<TS 783 S
74 17 12 VS3 1
<TS 784 S
74 17 22 VS4
-0.88
<TS 785 S
74 19 15 VS4
-0.87
<TS 786 S
74 19 16 DSC
-1.76
<TS 787 S
74 21 13 VS3 0.98
<TS 788 S
74 23 15 VS3
-1.08
<TS 789 S
74 23 16 VS4
-0.68
<TS 790 S
74 23 14 DSC 1.54
<TS 791 S
74 37 12 06H 0.94
<TS 792 S
74 37 11 DSC 1.7
<TS 793 S
74 37 10 04C
-0.96
<TS 794 S
74 43 11 VS3
-0.92
<TS 795 S
74 43 18 VS4
-0.7
<TS 796 S
74 45 16 VS5
-0.81
<TS 797 S
74 47 7
06C 0
<TS 798 S
74 51 9
03C
-0.96
<TS 799 S
74 53 9
VS3
-0.83
<TS 800 S
74 55 16 04C 0.83
<TS 801 S
74 71 15 03H 0.87
<TS 802 S
74 107 14 04H
-0.9
<TS 803 S
74 117 18 VS3
-1.02
<TS 804 S
74 119 15 04H 1
<TS 805 S
74 119 15 03H 0.9
<TS 806 S
74 127 18 DSH
-1.61
<TS 807 S
74 141 19 VS5
-0.72
<TS 808 S
75 16 12 02H 0.86
<TS 809 S
75 16 11 06H 0.98
<TS 810 S
75 24 13 VS3 0.2
<TS 811 S
75 24 14 DSC
-1.32
<TS 812 S
75 36 19 VS3 0.83
<TS 813 S
75 42 15 04C 0.7
<TS 814 S
75 60 16 03C 0.79
<TS 815 S
75 84 9
02C 0.76
<TS 816 S
75 102 17 04H 1.01
<TS 817 S
75 104 16 03H 0.94
<TS 818 S
75 106 14 02H
-0.84
<TS 819 S
75 112 13 03H
-0.88
<TS 820 S
75 132 11 06H
-0.91
<TS 821 S
75 132 12 DSH
-1.68
<TS 822 S
76 15 21 DSH 1.73
<TS 823 S
76 21 28 VS4 0.92
<TS 824 S
76 21 17 VS4
-0.83
<TS 825 S
76 21 15 VS3 0.96
<TS 826 S
76 25 17 06H 0.98
<TS 827 S
76 29 21 VS4 0
<TS 828 S
76 29 20 VS3 0.63
<TS Page D-16
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 829 B
76 29 20 VS3 0.07
<TS 830 B
76 29 14 VS3
-0.85
<TS 831 B
76 33 19 DBH 1.87
<TS 832 B
76 35 20 DBH 1.73
<TS 833 B
76 41 13 05C
-0.99
<TS 834 B
76 41 13 03C
-0.17
<TS 835 B
76 51 22 VS3 0.74
<TS 836 B
76 55 20 DBH 1.53
<TS 837 B
76 59 16 05H 0.93
<TS 838 B
76 59 17 VS3
-0.85
<TS 839 B
76 65 10 VS4
-0.09
<TS 840 B
76 73 8
02H
-0.09
<TS 841 B
76 113 13 04H 0.11
<TS 842 B
76 117 13 DBC
-1.14
<TS 843 B
76 121 17 04C 0.89
<TS 844 B
76 127 17 DBH
-1.51
<TS 845 B
76 141 26 DBH 1.93
<TS 846 B
76 151 17 04C 0.81
<TS 847 B
77 34 21 VS3 0.75
<TS 848 B
77 34 8
VS3 0.09
<TS 849 B
77 48 17 VS4 1
<TS 850 B
77 50 12 05H
-0.8
<TS 851 B
77 56 10 DBH 0.84
<TS 852 B
77 86 15 02C 0.81
<TS 853 B
77 86 10 02C
-0.98
<TS 854 B
77 104 20 05H 0.91
<TS 855 B
77 104 21 05C 0.81
<TS 856 B
77 116 19 04H
-0.84
<TS 857 B
77 150 19 DBH 1.2
<TS 858 B
77 150 24 VS4
-0.72
<TS 859 B
77 150 22 VS4 0.98
<TS 860 B
78 23 19 DBH
-1.72
<TS 861 B
78 23 13 VS5 1.09
<TS 862 B
78 35 15 DBH
-1.39
<TS 863 B
78 47 19 02C 0.82
<TS 864 B
78 57 19 03C 0.79
<TS 865 B
78 61 21 VS3
-0.94
<TS 866 B
78 79 16 VS4 0.97
<TS 867 B
78 81 15 03H 1
<TS 868 B
78 87 15 03C
-0.91
<TS 869 B
78 91 18 07H 1.53
<TS 870 B
78 105 11 02H
-0.75
<TS 871 B
78 109 15 03H 0.96
<TS 872 B
78 109 10 03H 0.19
<TS 873 B
78 109 15 02H
-0.84
<TS 874 B
79 24 13 VS3
-0.59
<TS 875 B
79 24 13 VS3 1.07
<TS 876 B
79 24 27 VS4 0.11
<TS 877 B
79 24 29 VS4 0.85
<TS 878 B
79 30 12 DBC 1.61
<TS 879 B
79 44 14 03C 0.79
<TS 880 B
79 52 16 02C
-0.22
<TS Page D-17 I
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 881 B
79 54 13 03C 0.76
<TS 882 B
79 60 8
03C
-0.98
<TS 883 B
79 62 14 02C
-0.19
<TS 884 B
79 62 13 04C
-1.02
<TS 885 B
79 78 12 VS5 0.8
<TS 886 B
79 86 19 03H 0.8
<TS 887 B
79 122 18 03H 0.85
<TS 888 B
79 128 12 03C 0.78
<TS 889 B
80 17 29 DBH 1.68
<TS 890 B
80 49 16 VS4
-0.83
<TS 891 B
80 49 16 VS3
-0.89
<TS 892 B
80 95 20 04H 0.93
<TS 893 B
80 95 15 02H 0.88
<TS 894 B
80 95 16 03H 0.92
<TS 895 B
80 97 14 VS3
-0.13
<TS 896 B
80 115 22 VS4
-0.76
<TS 897 B
80 145 21 VS5 1.1
<TS 898 B
80 145 14 VS5
-0.62
<TS 899 B
80 145 33 VS4
-0.6
<TS 900 B
80 149 16 01H
-0.83
<TS 901 B
81 22 27 VS4 0.84
<TS 902 B
81 22 29 VS3 0.86
<TS 903 B
81 24 14 VS3 0.99
<TS 904 B
81 24 18 VS3
-0.86
<TS 905 B
81 52 33 VS3 0.78
<TS 906 B
81 60 14 03C 0.79
<TS 907 B
81 92 14 02C
-0.94
<TS 908 B
81 112 15 02H 0.94
<TS 909 B
81 126 18 07C 0.97
<TS 910 B
81 148 14 VS4
-0.85
<TS 911 B
81 148 15 VS4 0.94
<TS 912 B
81 148 20 04C
. 0.72
<TS 913 B
81 148 11 03C 0.73
<TS 914 B
82 19 14 03H 0.82
<TS 915 B
82 19 14 04H 0.91
<TS 916 B
82 19 10 VS4 1
<TS 917 B
82 21 12 VS5
-0.7
<TS 918 B
82 41 22 VS3 1
<TS 919 B
82 43 9
VS3
-0.81
<TS 920 B
82 43 27 VS3 0
<TS 921 B
82 43 20 VS3 0.75
<TS 922 B
82 43 9
VS4
-0.79
<TS 923 B
82 43 17 VS4 0.81
<TS 924 B
82 43 13 VS4
-0.02
<TS 925 B
82 43 24 VS5
-0.66
<TS 926 B
82 43 19 VS5
-0.13
<TS 927 B
82 43 22 VS5 0.28
<TS 928 B
82 43 12 VS5 0.88
<TS 929 B
82 59 11 02C 0.81
<TS 930 B
82 91 14 04C
-0.92
<TS 931 B
82 105 11 02H 1.04
<TS 932 B
82 129 16 DBH 1.88
<TS Page D-18
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 933 B
82 137 20 DBH 1.71
<TS 934 B
82 143 27 VS3
-0.85
<TS 935 B
82 143 20 VS4
-0.76
<TS 936 B
82 145 20 VS3
-0.83
<TS 937 B
82 145 20 VS3 0.94
<TS 938 B
82 145 18 VS4
-0.78
<TS 939 B
82 145 27 VS4 0.87
<TS 940 B
83 20 11 DBH 1.79
<TS 941 B
83 28 20 VS6
-0.88
<TS 942 B
83 28 20 VS6 0.88
<TS 943 B
83 54 13 04H 0.94
<TS 944 B
83 64 17 03C 0.84
<TS 945 B
83 106 11 03H 0.9
<TS 946 B
83 148 30 VS4
-0.99
<TS 947 B
84 19 19 07H
-1.1
<TS 948 B
84 25' 12 VS2
-0.79
<TS 949 B
84 55 15 02C 0.78
<TS 950 B
84 77 14 05C
-0.95
<TS 951 B
84 79 12 03H 0.99
<TS 952 B
84 81 14 VS5
-0.83
<TS 953 B
84 81 15 02C 0.79
<TS 954 B
84 87 18 03H 0.93
<TS 955 B
84 93 20 02C
-0.96
<TS 956 B
84 107 15 02H
-0.77
<TS 957 B
84 125 14 04H
-0.81
<TS 958 B
84 145 17 03C
-0.87
<TS 959 B
84 147 27 DBH 1.8
<TS 960 B
85 20 16 VS4 0.98
<TS 961 B
85 20 12 VS4
-0.72
<TS 962 B
85 36 12 04H
-0.8
<TS 963 B
85 36 17 VS6
-0.8
<TS 964 B
85 78 17 05H 0.99
<TS 965 B
85 110 15 04C 0.78
<TS 966 B
85 140 12 04C 0.85
<TS 967 B
85
. 142 17 03C
-0.85
<TS 968 B
85 144 15 03C
-0.89
<TS 969 B
85 146 13 04C
-0.94
<TS 970 B
86 51 17 03C 0.89
<TS 971 B
86 61 8
02C 0.07
<TS 972 B
86 79 16 04H 0.9
<TS 973 B
86 89 16 03C 0.79
<TS 974 B
86 91 10 03C
-0.94
<TS 975 B
86 111 14 04C
-0.95
<TS 976 B
87 20 15 VS4
-0.91
<TS 977 B
87 30 13 04H 0.93
<TS 978 B
87 38 12 VS6
-0.78
<TS 979 B
87 62 15 04C
-0.93
<TS 980 B
87 82 15 03H 0.91
<TS 981 B
87 84 16 02C 0.78
<TS 982 B
87 88 20 04C
-0.85
<TS 983 B
87 146 33 03C 0.69
<TS 984 B
87 146 18 VS4 1
<TS Page D-19
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 985 B
87 146 22 VS4
-0.77
<TS 986 B
88 27 22 DBH 1.99
<TS 987 B
88 27 14 04H 0.87
<TS 988 B
88 29 14 06H 0.97
<TS 989 B
88 67 14 VS2 0.82
<TS 990 B
88 67 13 VS2
-0.7
<TS 991 B
88 79 16 07C 0.84
<TS 992 B
88 87 18 05C 0.83
<TS 993 B
88 95 26 03C 0.78
<TS 994 B
88 107 14 04C
-0.98
<TS 995 B
89 38 8
05H
-0.78
<TS 996 B
89 38 11 VS2
-0.82
<TS 997 B
89 42 10 VS6 0.88
<TS 998 B
89 44 11 VS6
-0.84
<TS 999 B
89 56 13 02C 0.78
<TS 1000 B
89 58 10 DBC 1.73
<TS 1001 B
89 60 14 04C
-0.89
<TS 1002 B
89 78 15 07C 0.77
<TS 1003 B
89 82 16 07C 0.77
<TS 1004 B
89 84 17 03H 0.86
<TS 1005 B
89 92 18 04C 0.35
<TS 1006 B
89 100 16 03H 0.9
<TS 1007 B
89 104 16 04H 0.95
<TS 1008 B
89 104 13 05C
-0.92
<TS 1009 B
89 104 14 04C
-0.98
<TS 1010 B
90 23 12 VS4
-0.87
<TS 1011 B
90 55 17 VS2 0.96
<TS 1012 B
90 57 16 02C 0.76
<TS 1013 B
90 65 17 03C 0.77
<TS 1014 B
90 87 12 02C
-0.2
<TS 1015 B
90 87 11 02C
-0.96
<TS 1016 B
90 95 16 04C 0.81
<TS 1017 B
90 97 16 04C 0.83
<TS 1018 B
90 115 13 03H
-0.84
<TS 1019 B
90 127 16 04H
-0.85
<TS 1020 B
90 131 13 07H 1
<TS 1021 B
91 22 26 VS6 1.01
<TS 1022 B
91 32 18 02C
-0.9
<TS 1023 B
91 38 15 03H
-0.84
<TS 1024 B
91 54 16 02C 0.91
<TS 1025 B
91 58 15 03C 0.78
<TS 1026 B
91 60 12 04C
-0.96
<TS 1027 B
91 64 20 03C
-0.98
<TS 1028 B
91 70 11 06C
-0.86
<TS 1029 B
91 86 19 VS6 0.9
<TS 1030 B
91 88 18 04H
-0.73
<TS 1031 B
91 94 18 06C
-0.92
<TS 1032 B
91 124 20 04C 0.76
<TS 1033 B
91 144 21 VS4 0.87
<TS 1034 B
91 144 20 VS4
-0.89
<TS 1035 B
92 23 9
03H
-0.74
<TS 1036 B
92 23 7
VS4
-0.98
<TS Page D-20
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1037 B
92 23 10 VS4 0.76
<TS 1038 B
92 23 11 02C 0.74
<TS 1039 B
92 23 8
02C
-0.99
<TS 1040 B
92 31 13 VS2
-0.81
<TS 1041 B
92 31 9
VS2 0.87
<TS 1042 B
92 49 13 05H 0.89
<TS 1043 B
92 55 15 03C 0.74
<TS 1044 B
92 57 16 04H 0.85
<TS 1045 B
92 61 13 03C
-0.91
<TS 1046 B
92 69 17 04C 0.81
<TS 1047 B
92 73 13 VS2 0.84
<TS 1048 B
92 75 12 05H 1
<TS 1049 B
92 83 20 05H 0.93
<TS 1050 B
92 97 15 04C 0.76
<TS 1051 B
92 97 10 04C 0.02
<TS 1052 B
92 105 14 04C
-0.94
<TS 1053 B
93 30 18 VS4
-1.01
<TS 1054 B
93 42 14 VS2 0.82
<TS 1055 B
93 56 11 02C 0.82
<TS 1056 B
93 62 12 02C 0.83
<TS 1057 B
93 62 13 03C 0.81
<TS 1058 B
93 98 14 04C
-0.96
<TS 1059 B
93 104 14 04H
-0.8
<TS 1060 B
93 112 17 VS6 0.82
<TS 1061 B
93 132 14 04H 0.9
<TS 1062 B
94 37 18 VS2
-0.65
<TS 1063 B
94 57 18 02C 0.8
<TS 1064 B
94 81 15 02C 0.81
<TS 1065 B
94 93 12 04C
-0.17
<TS 1066 B
94 93 9
04C
-0.93
<TS 1067 B
94 101 15 06H
-0.81
<TS 1068 B
94 111 15 VS6
-0.64
<TS 1069 B
94 115 17 04C
-1
<TS 1070 B
94 129 18 04H 0.89
<TS 1071 B
94 131 13 03C
-0.89
<TS 1072 B
95 24 14 VS4
-0.66
<TS 1073 B
95 24 12 VS4
-0.09
<TS 1074 B
95 24 12 VS4 0.81
<TS 1075 B
95 36 14 VS4
-0.85
<TS 1076 B
95 36 15 VS4 0.95
<TS 1077 B
95 42 16 DBC
-0.5
<TS 1078 B
95 70 14 04H 0.92
<TS 1079 B
95 70 17 VS6
-0.75
<TS 1080 B
95 84 22 07C 0.79
<TS 1081 B
95 102 19 05H 0.89
<TS 1082 B
95 104 11 03C 0.04
<TS 1083 B
95 106 20 04C
-1
<TS 1084 B
95 116 24 VS2
-0.96
<TS 1085 B
95 126 11 04H 0.9
<TS 1086 B
95 134 14 VS2 0.13
<TS 1087 B
95 134 20 VS2 1.05
<TS 1088 B
95 136 19 03C
-0.35
<TS Page D-21
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1089 8
95 138 37 VS4 0.96
<TS 1090 8
95 140 18 03C
-0.96
<TS 1091 8
95 142 20 VS4 1.02
<TS 1092 8
96 25 10 02H
-0.93
<TS 1093 8
96 29 19 VS4 0.89
<TS 1094 8
96 57 13 02H 0.83
<TS 1095 8
96 57 18 VS4 1.07
<TS 1096 8
96 65 11 04C 0.74
<TS 1097 8
96 65 11 02C 0.79
<TS 1098 8
96 71 9
04H
-0.09
<TS 1099 8
96 71 16 04H
-0.94
<TS 1100 8
96 79 12 VS2 0.64
<TS 1101 8
96 95 22 VS2
-0.77
<TS 1102 8
96 95 15 VS2 0.17
<TS 1103 8
96 95 19 VS2 1.03
<TS 1104 8
96 117 21 VS2 0.81
<TS 1105 8
96 137 18 VS4
-0.15
<TS 1106 8
96 137 24 VS4 0.95
<TS 1107 8
96 137 20 04C
-0.24
<TS 1108 8
96 137 14 03C 0.76
<TS 1109 8
96 139 21 03C
-0.95
<TS 1110 8
96 141 24 VS4 0.9
<TS 1111 8
97 26 15 VS4
-0.59
<TS 1112 8
97 28 20 03C 0.77
<TS 1113 8
97 38 13 05H 0.93
<TS 1114 8
97 40 12 VS2
-0.78
<TS 1115 8
97 42 15 VS2
-0.88
<TS 1116 8
97 60 19 VS2 0.95
<TS 1117 8
97 60 19 06C
- o.67
<TS 1118 8
97 72 15 04H 0.96
<TS 1119 8
97 84 11 07C
-0.17
<TS 1120 8
97 84 16 07C
-1
<TS 1121 8
97 130 13 04H 0.92
<TS 1122 8
97 140 13 VS4
-0.8
<TS 1123 8
98 27 11 VS4
-0.87
<TS 1124 8
98 27 13 VS4 1.05
<TS 1125 8
98 27 19 04C
-1.01
<TS 1126 8
98 39 14 VS4 0.69
<TS 1127 8
98 41 10 VS2
-0.78
<TS 1128 8
98 41 23 VS4 0.82
<TS 1129 8
98 41 17 VS2 0.91
<TS 1130 8
98 49 20 VS2
-0.43
<TS 1131 8
98 55 32 VS2
-0.83
<TS 1132 8
98 59 17 VS2
-0.84
<TS 1133 8
98 59 14 VS2 0.92
<TS 1134 8
98 71 16 VS2 0.98
<TS 1135 8
98 71 8
VS2
-0.73
<TS 1136 8
98 79 15 D3C 0.83
<TS 1137 8
98 79 11 03C 0.07
<TS 1138 8
98 81 17 VS2 0.89
<TS 1139 8
98 117 17 VS2 0.88
<TS 1140 8
98 133 14 02C 0.8
<TS Page D-22
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1141 B
98 135 20 VS2 0.11
<TS 1142 B
98 135 27 VS4
-0.75
<TS 1143 B
98 135 25 VS4 0.99
<TS 1144 B
98 137 22 DBH 1.82
<TS 1145 B
98 139 19 03C
-0.87
<TS 1146 B
98 139 23 VS4 0.82
<TS 1147 B
98 139 15 04H
-0.15
<TS 1148 B
98 139 28 VS4 0.21
<TS 1149 B
99 32 15 02C 0.85
<TS 1150 B
99 50 22 05H 0.61
<TS 1151 B
99 52 12 03C 0.76
<TS 1152 B
99 132 25 VS2
-0.77
<TS 1153 B
99 132 16 VS2
-0.21
<TS 1154 B
99 132 29 VS2 0.73
<TS 1155 B
99 132 19 VS4 0.9
<TS 1156 B
99 136 18 04C 0.81
<TS 1157 B
100 27 20 VS4
-1
<TS 1158 B
100 27 10 VS4 0.85
<TS 1159 B
100 29 19 03C 0.77
<TS 1160 B
100 29 20 VS6
-0.85
<TS 1161 B
100 109 23 VS2
-0.71
<TS 1162 B
100 121 18 06C 0.84
<TS 1163 B
100 125 36 VS2
-0.71
<TS 1164 B
100 125 38 VS2 0.02
<TS 1165 B
100 125 18 VS2 0.78
<TS 1166 B
100 125 27 VS4 1.03
<TS 1167 B
100 125 27 VS6
-0.09
<TS 1168 B
100 125 24 VS6 0.95
<TS 1169 B
100 125 19 DBC
-1.47
<TS 1170 B
100 133 17 VS4
-0.73
<TS 1171 B
101 28 15 VS4
-0.68
<TS 1172 B
101 28 12 VS4 0
<TS 1173 B
101 30 11 03H
-0.83
<TS 1174 B
101 30 17 04C 0.83
<TS 1175 B
101 30 12 03C 0.77
<TS 1176 B
101 30 17 03C
-0.96
<TS 1177 B
101 32 19 VS2 0.72
<TS 1178 B
101 36 12 05H 0.92
<TS 1179 B
101 38 12 DBC 1.69
<TS 1180 B
101 54 19 02C 0.76
<TS 1181 B
101 78 14 05H 0.91
<TS 1182 B
101 98 17 04C
-1.09
<TS 1183 B
101 104 24 DBH 1.78
<TS 1184 B
101 136 18 03H 0.83
<TS 1185 B
102 31 21 02C
-1.01
<TS 1186 B
102 33 19 03C
-0.96
<TS 1187 B
102 35 23 03C 0.77
<TS 1188 B
102 41 14 06H 0.99
<TS 1189 B
102 49 13 VS2 0.91
<TS 1190 B
102 51 16 07C 0.83
<TS 1191 B
102 85 29 VS6
-0.73
<TS 1192 B
102 99 8
07C 0.04
<TS Page D-23
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1193 B
102 99 15 07C 0.71
<TS 1194 B
102 113 19 DBH 1.91
<TS 1195 B
102 127 15 VS4 0.73
<TS 1196 B
102 131 14 DBC 1.7
<TS 1197 B
102 137 22 VS4 1.01
<TS 1198 B
102 137 16 VS4
-0.65
<TS 1199 B
103 30 13 01C 0.07
<TS 1200 B
103 30 14 06C
-0.95
<TS 1201 B
103 36 8
07H 0.98
<TS 1202 B
103 36 12 07C 0.85
<TS 1203 B
103 48 14 VS4
-0.74
<TS 1204 B
103 48 9
DBC
-1.35
<TS 1205 B
103 48 10 07C 0.17
<TS 1206 B
103 62 18 03C 0.72
<TS 1207 B
103 64 30 VS2 0.85
<TS 1208 B
103 94 21 VS2
-0.9
<TS 1209 B
103 100 16 07C 0.73
<TS 1210 B
103 108 27 VS6
-0.69
<TS 1211 B
103 122 18 03H 0.84
<TS 1212 B
103 126 26 VS2 0.19
<TS 1213 B
103 126 21 VS4
-0.6
<TS 1214 B
103 126 34 VS6 0.91
<TS 1215 B
103 128 15 04C 0.76
<TS 1216 B
103 130 21 VS2
-0.04
<TS 1217 B
103 132 11 04H 0.96
<TS 1218 B
103 132 22 VS2 0
<TS 1219 B
103 136 24 VS4 1.05
<TS 1220 B
103 136 22 VS4
-0.73
<TS 1221 B
104 31 22 VS4 0.72
<TS 1222 B
104 31 18 02C
-0.24
<TS 1223 B
104 33 13 03H 0.15
<TS 1224 B
104 59 15 VS6
-0.88
<TS 1225 B
104 59 16 VS4 0.94
<TS 1226 B
104 79 16 VS6
-0.73
<TS 1227 B
104 91 14 VS2
-0.67
<TS 1228 B
104 95 17 VS2
-0.62
<TS 1229 B
104 95 18 VS2 0.09
<TS 1230 B
104 95 20 VS2 0.88
<TS 1231 B
104 117 14 05C 0.83
<TS 1232 B
104 131 12 03C 0.74
<TS 1233 B
105 30 13 VS4 0.22
<TS 1234 B
105 30 27 VS4 0.76
<TS 1235 B
105 30 17 02C 0.7
<TS 1236 B
105 32 11 01H 0.96
<TS 1237 B
105 32 8
VS4
-0.82
<TS 1238 B
105 32 10 VS4 1.13
<TS 1239 B
105 34 19 02C 0.09
<TS 1240 B
105 36 12 04H
-0.13
<TS 1241 B
105 38 21 03C 0.83
<TS 1242 B
105 40 10 03C
-0.98
<TS 1243 B
105 42 12 07C 0.73
<TS 1244 B
105 54 21 VS6
-0.69
<TS Page D-24
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1245 B
105 58 12 VS2 0.99
<TS 1246 B
105 58 25 VS2
-0.82
<TS 1247 B
105 58 22 VS6 0.88
<TS 1248 B
105 58 20 VS4 0.11
<TS 1249 B
105 58 19 VS4
-0.64
<TS 1250 B
105 68 15 VS2 0.14
<TS 1251 B
105 76 19 VS2 1
<TS 1252 B
105 78 14 VS2
-0.18
<TS 1253 B
105 78 15 VS2 1
<TS 1254 B
105 78 27 VS6
-0.73
<TS 1255 B
105 78 29 VS6 0.99
<TS 1256 B
105 80 24 VS2
-0.21
<TS 1257 B
105 88 13 VS2
-0.88
<TS 1258 B
105 88 14 07C
-0.96
<TS 1259 B
105 90 14 VS2 0.96
<TS 1260 B
105 90 14 VS4 1.18
<TS 1261 B
105 90 15 07C 0.81
<TS 1262 B
105 90 15 03C 0.39
<TS 1263 B
105 96 15 04C
-1.02
<TS 1264 B
105 110 24 DBH 0.66
<TS 1265 B
105 118 15 DBH 1.86
<TS 1266 B
105 120 17 03H
-0.83
<TS 1267 B
105 130 16 VS2
-0.63
<TS 1268 B
105 130 12 VS2 0.26
<TS 1269 B
105 130 23 03C 0.83
<TS 1270 B
105 134 19 02C 0.74
<TS 1271 B
105 136 15 VS4
-0.82
<TS 1272 B
105 136 17 01H 0.93
<TS 1273 B
106 31 14 VS4 0.37
<TS 1274 B
106 31 24 VS4 0.96
<TS 1275 B
106 31 17 03C 0.81
<TS 1276 B
106 35 17 03H 0.93
<TS 1277 B
106 35 21 04H 0.87
<TS 1278 B
106 35 16 03C 0.81
<TS 1279 B
106 35 17 02C
-0.15
<TS 1280 B
106 37 22 VS2
-0.54
<TS 1281 B
106 39 20 VS2
-0.69
<TS 1282 B
106 39 20 03C 0.79
<TS 1283 B
106 49 12 04H
-0.04
<TS 1284 B
106 51 9
VS2 1.08
<TS 1285 B
106 51 15 07C 0.65
<TS 1286 B
106 57 22 VS2 1.07
<TS 1287 B
106 63 14 VS4
-0.75
<TS 1288 B
106 63 23 VS2 0.18
<TS 1289 B
106 71 14 VS2
-0.23
<TS 1290 B
106 75 17 VS2 1.1
<TS 1291 B
106 77 23 VS2 1
<TS 1292 B
106 101 11 VS2
-0.36
<TS 1293 B
106 101 17 VS2
-0.83
<TS 1294 B
106 113 16 VS2
-0.13
<TS 1295 B
106 129 17 04C 0.78
<TS 1296 B
106 131 15 03C
-0.24
<TS Page D-25
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1297 B
107 32 16 VS4
-0.61
<TS 1298 B
107 34 13 VS6
-0.69
<TS 1299 B
107 36 19 VS2 0.8
<TS 1300 B
107 40 20 VS2 0.97
<TS 1301 B
107 42 31 VS2
-0.87
<TS 1302 B
107 42 33 VS2 0.85
<TS 1303 B
107 42 30 VS4 0.8
<TS 1304 B
107 42 20 VS4 0.24
<TS 1305 B
107 42 16 VS6
-0.89
<TS 1306 B
107 42 10 VS6 0.91
<TS 1307 B
107 44 16 06C
-0.26
<TS 1308 B
107 46 18 VS6
-0.72
<TS 1309 B
107 46 8
VS6 1
<TS 1310 B
107 52 15 VS6
-0.58
<TS 1311 B
107 52 14 07C 0.89
<TS 1312 B
107 58 16 DBH 1.84
<TS 1313 B
107 78 16 VS2
-0.87
<TS 1314 B
107 78 22 VS2 0.91
<TS 1315 B
107 82 34 VS2
-0.95
<TS 1316 B
107 82 30 VS2 0.86
<TS 1317 B
107 82 14 VS4 0.14
<TS 1318 B
107 96 26 VS2 0.88
<TS 1319 B
107 96 15 VS4 0.15
<TS 1320 B
107 114 14 VS2 0.34
<TS 1321 B
107 116 29 VS2 0.73
<TS 1322 B
107 116 32 VS2 0.06
<TS 1323 B
107 116 29 VS2
-0.79
<TS 1324 B
107 120 16 DBC 1.61
<TS 1325 B
107 124 18 04C 0.74
<TS 1326 B
107 130 21 03H 0.86
<TS 1327 B
107 132 17 07C 0.75
<TS 1328 B
107 132 18 04C 0.76
<TS 1329 B
107 132 32 03C 0.76
<TS 1330 B
107 132 19 02C 0.8
<TS 1331 B
108 33 30 VS4 0.89
<TS 1332 B
108 33 12 DBH
-0.92
<TS 1333 B
108 33 24 08H 0.62
<TS 1334 B
108 37 11 04C
-1.01
<TS 1335 B
108 37 23 03C
-0.37
<TS 1336 B
108 37 12 02C 0.69
<TS 1337 B
108 43 18 VS4
-0.88
<TS 1338 B
108 45 17 07C 0.8
<TS 1339 B
108 47 23 VS2
-0.54
<TS 1340 B
108 49 10 05H 0.96
<TS 1341 B
108 51 27 VS2
-0.54
<TS 1342 B
108 51 14 VS2 0.99
<TS 1343 B
108 59 21 VS2 0.86
<TS 1344 B
108 59 23 VS2
-0.82
<TS 1345 B
108 69 13 05H 0.95
<TS 1346 B
108 113 28 VS4 0.99
<TS 1347 B
108 113 29 VS4
-0.79
<TS 1348 B
108 115 18 07C 0.75
<TS Page D-26
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1349 B
108 129 12 04H
-0.04
<TS 1350 B
108 131 14 03C 0
<TS 1351 B
108 131 18 02C 0.95
<TS 1352 B
108 133 20 02C 0
<TS 1353 B
109 34 20 VS4
-0.67
<TS 1354 B
109 34 19 04C 0
<TS 1355 B
109 40 17 VS2
-0.76
<TS 1356 B
109 40 17 VS2 1.04
<TS 1357 B
109 40 20 VS4 0.04
<TS 1358 B
109 48 14 VS4
-0.82
<TS 1359 B
109 52 13 VS6 0.96
<TS 1360 B
109 52 37 VS2 0.9
<TS 1361 B
109 52 19 VS2
-0.88
<TS 1362 B
109 62 21 07C 0.73
<TS 1363 B
109 64 14 08C
-0.87
<TS 1364 B
109 78 18 04C
-0.97
<TS 1365 B
109 84 13 04H
-0.09
<TS 1366 B
109 96 14 VS2
-0.88
<TS 1367 B
109 104 24 VS2 0.98
<TS 1368 B
109 112 20 07H 0.92
<TS 1369 B
109 112 17 VS2
-0.54
<TS 1370 B
109 112 19 07C 0.82
<TS 1371 B
109 114 29 VS6
-1.16
<TS 1372 B
109 114 37 VS4
-0.93
<TS 1373 B
109 114 28 VS2
-0.13
<TS 1374 B
109 114 13 VS2
-0.73
<TS 1375 B
109 114 19 VS2 0.02
<TS 1376 B
109 120 15 04C
-0.97
<TS 1377 B
109 126 23 04H 0.88
<TS 1378 B
109 130 12 04C 0.65
<TS 1379 B
109 130 16 03C 0.93
<TS 1380 B
109 130 26 02C 0.72
<TS 1381 B
109 132 20 05C 0.85
<TS 1382 B
109 132 25 04C
-0.13
<TS 1383 B
110 37 19 04C
-0.94
<TS 1384 B
110 37 12 03C
-0.96
<TS 1385 B
110 41 11 02C 0.09
<TS 1386 B
110 51 11 05H 0.87
<TS 1387 B
110 55 14 VS2 0.9
<TS 1388 B
110 55 32 VS2
-0.86
<TS 1389 B
110 79 24 VS2 0.02
<TS 1390 B
110 97 20 08H 1.58
<TS 1391 B
110 97 18 VS2
-0.7
<TS 1392 B
110 131 16 02C 0.78
<TS 1393 B
110 131 18 02C
-0.97
<TS 1394 B
110 131 29 03C 0.83
<TS 1395 B
110 131 13 03C
-0.93
<TS 1396 B
111 40 14 DBC
-1.74
<TS 1397 B
111 50 22 VS2 0.77
<TS 1398 B
111 56 17 08H 0.15
<TS 1399 B
111 66 17 07H 0.95
<TS 1400 B
111 84 12 04H
-0.81
<TS Page D-27
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1401 B
111 122 15 03C
-1.02
<TS 1402 B
111 122 14 03C
-0.22
<TS 1403 B
111 128 15 03H
-0.81
<TS 1404 B
111 130 18 02H 0.17
<TS 1405 B
111 130 24 VS4 0.96
<TS 1406 B
112 37 32 04C
-0.99
<TS 1407 B
112 39 12 02H 0.93
<TS 1408 B
112 43 20 VS2
-0.8
<TS 1409 B
112 43 16 VS2 1.03
<TS 1410 B
112 43 15 VS4
-0.69
<TS 1411 B
112 45 12 03H 0.9
<TS 1412 B
112 45 15 VS2
-0.77
<TS 1413 B
112 47 28 VS2
-0.78
<TS 1414 B
112 47 15 VS2 1.06
<TS 1415 B
112 47 24 VS4 1.03
<TS 1416 B
112 53 18 VS2
-0.84
<TS 1417 8
112 53 17 VS2 0.88
<TS 1418 B
112 59 14 VS2 0.84
<TS 1419 8
112 59 15 VS2 0.24
<TS 1420 B
112 71 15.
VS2
-0.75
<TS 1421 B
112 79 13 04H
-0.73
<TS 1422 B
112 79 22 VS2 0.64
<TS 1423 8
112 121 16 02C 0.82
<TS 1424 8
112 127 27 03C 0.09
<TS 1425 8
113 36 14 VS2
-0.43
<TS 1426 8
113 36 12 VS2 0.95
<TS 1427 B
113 36 16 VS6
-0.86
<TS 1428 B
113 36 12 02C 0.77
<TS 1429 B
113 38 16 VS4
-0.69
<TS 1430 B
113 40 12 04H
-0.09
<TS 1431 B
113 40 14 VS4
-0.86
<TS 1432 B
113 40 16 03C
-0.61
<TS 1433 B
113 42 11 05H
-0.09
<TS 1434 B
113 42 17 VS4 0.97
<TS 1435 8
113 42 12 03C
-0.28
<TS 1436 B
113 44 14 01H 0.93
<TS 1437 8
113 66 10 06H 1.03
<TS 1438 8
113 70 20 07C 0.77
<TS 1439 8
113 70 19 07C 0
<TS 1440 B
113 84 14 02H
-0.83
<TS 1441 8
113 84 10 04H
-0.77
<TS 1442 B
113 110 15 04C 0.72
<TS 1443 B
113 130 22 VS4
-0.77
<TS 1444 8
114 37 25 DBH 1.3
<TS 1445 B
114 37 13 VS4
-0.6
<TS 1446 B
114 37 25 VS4 0.99
<TS 1447 B
114 37 12 04C 0.85
<TS 1448 B
114 37 19 VS2
-0.69
<TS 1449 B
114 37 26 VS2 0
<TS 1450 B
114 39 23 VS2
-0.71
<TS 1451 B
114 39 34 VS4 0.84
<TS 1452 B
114 39 12 02C 0.78
<TS Page D-28
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1453 B
114 127 15 05C 0.78
<TS 1454 B
114 127 25 03C 0.8
<TS 1455 B
114 129 15 VS4
-0.73
<TS 1456 B
115 38 11 02C 0.82
<TS 1457 B
115 38 11 VS4
-0.65
<TS 1458 B
115 38 31 01C 0
<TS 1459 B
115 68 11 05H 0.93
<TS 1460 B
115 84 19 03H
-0.81
<TS 1461 B
115 86 21 03H 0.86
<TS 1462 B
115 122 13 07H 0.93
<TS 1463 B
115 124 20 05C
-0.89
<TS 1464 B
115 126 19 03C 0.95
<TS 1465 B
115 126 15 03C
-0.91
<TS 1466 B
116 43 18 VS4 0.82
<TS 1467 B
116 45 15 06H 0.93
<TS 1468 B
116 45 16 VS2 0.02
<TS 1469 B
116 45 18 VS4 0.93
<TS 1470 B
116 47 16 VS4 0.86
<TS 1471 B
116 55 13 VS2
-0.88
<TS 1472 B
116 55 17 VS4 0.81
<TS 1473 B
116 77 16 VS2 0.59
<TS 1474 B
116 77 12 07C 0.74
<TS 1475 B
116 81 18 VS7
-0.89
<TS 1476 B
116 81 9
07C
-0.19
<TS 1477 B
116 81 16 07C
-0.93
<TS 1478 B
116 97 10 04C
-0.26
<TS 1479 B
116 103 15 05C 0.83
<TS 1480 B
116 111 15 05H
-0.86
<TS 1481 B
116 111 19 04C
-1
<TS 1482 B
116 115 23 VS4 0.84
<TS 1483 B
116 117 15 03C
-0.98
<TS 1484 B
116 117 19 03C
-0.22
<TS 1485 B
116 125 17 05C 0.79
<TS 1486 B
116 125 16 04C 0
<TS 1487 B
116 125 19 04C 0.78
<TS 1488 B
116 125 39 03C 0.72
<TS 1489 B
117 40 8
05C 0.77
<TS 1490 B
117 40 18 04C
-0.22
<TS 1491 B
117 40 19 03C
-0.93
<TS 1492 B
117 40 13 02C 0.72
<TS 1493 B
117 40 9
01C
-0.94
<TS 1494 B
117 40 20 02C
-0.86
<TS 1495 B
117 40 11 02C
-0.24
<TS 1496 B
117 44 9
02C 0.74
<TS 1497 B
117 48 10 03C
-1
<TS 1498 B
117 66 13 07C 0.9
<TS 1499 B
117 66 11 06H 1
<TS 1500 B
117 68 18 05H 0.94
<TS 1501 B
117 82 11 06H
-0.76
<TS.
1502 B
117 90 14 08C 0.86
<TS 1503 B
117 112 21 04H 1.03
<TS 1504 B
118 41 10 03C
-0.24
<TS Page D-29
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1505 B
118 41 9
02H 0.92
<TS 1506 B
118 43 17 VS6 0
<TS 1507 B
118 43 15 VS4 0.99
<TS 1508 B
118 73 15 VS6
-0.85
<TS 1509 B
118 73 16 VS?
-0.75
<TS 1510 B
118 87 14 VS2 1.03
<TS 1511 B
118 89 26 VS2 0.96
<TS 1512 B
118 89 16 VS4 0.66
<TS 1513 B
118 97 15 VS2
-0.77
<TS 1514 B
118 101 13 08C 0.79
<TS 1515 B
118 105 20 VS4
-0.62
<TS 1516 B
118 117 17 04C
-0.17
<TS 1517 B
118 123 21 04C
-0.95
<TS 1518 B
118 123 14 02C 0.8
<TS 1519 B
119 42 16 03C 0.35
<TS 1520 B
119 42 21 04C
-0.63
<TS 1521 B
119 42 10 02H 0.9
<TS 1522 B
119 42 16 VS?
-0.74
<TS 1523 B
119 44 18 02H 0.9
<TS 1524 B
119 44 15 01C 0.7
<TS 1525 B
119 46 17 02C 0.78
<TS 1526 B
119 72 20 DBC 1.09
<TS 1527 B
119 88 21 08C 0.82
<TS 1528 B
119 88 9
08C
-0.24
<TS 1529 B
119 104 17 VS1
-0.66
<TS 1530 B
119 112 11 03C
-0.89
<TS 1531 B
119 112 19 03C 0.84
<TS 1532 B
119 112 20 04C 0.78
<TS 1533 B
120 43 16 01C
-0.92
<TS 1534 B
120 45 13 02C 0.8
<TS 1535 B
120 47 22 03C 0.77
<TS 1536 B
120 47 8
03C
-1.02
<TS 1537 B
120 49 10 03C
-0.92
<TS 1538 B
120 61 18 08C 0.78
<TS 1539 B
120 103 14 07H 0.89
<TS 1540 B
120 105 19 VS2
-0.73
<TS 1541.
B 120 113 20 VS2 0.9
<TS 1542 B
120 113 26 VS2
-0.84
<TS 1543 B
120 115 26 03C 0.76
<TS 1544 B
121 44 15 01H 0.9
<TS 1545 B
121 114 18 VS4
-0.88
<TS 1546 B
121 118 21 02C 0.78
<TS 1547 B
121 122 14 02H 0.86
<TS 1548 B
122 71 13 05H 0.93
<TS 1549 B
122 71 14 VS2
-0.71
<TS 1550 B
123 52 17 02C 0.7
<TS 1551 B
123 72 13 VS4
-0.77
<TS 1552 B
123 72 13 VS?
0.77
<TS 1553 B
123 116 39 VS6
-0.45
<TS 1554 B
123 116 16 05C
-0.96
<TS 1555 B
123 116 11 04C 0.76
<TS 1556 B
123 116 11 03C 0.8
<TS Page D-30
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1557 B
123 118 36 VS6
-0.69
<TS 1558 B
123 118 20 VS7
-0.9
<TS 1559 B
124 47 12 03C 0.74
<TS 1560 B
124 47 12 01C
-0.22
<TS 1561 B
124 49 15 02C
-1.07
<TS 1562 B
124 51 17 VS4 0.65
<TS 1563 B
124 55 13 05H
-0.11
<TS 1564 B
124 57 17 VS7
-0.86
<TS 1565 B
124 73 11 VS2 0.78
<TS 1566 B
124 85 13 VS2 0.19
<TS 1567 B
124 85 9
VS2 0.71
<TS 1568 B
124 85 12 VS4
-0.39
<TS 1569 B
124 87 17 VS4 0.9
<TS 1570 B
124 93 15 VS2
-0.69
<TS 1571 B
124 93 26 VS2 0.06
<TS 1572 B
124 93 11 VS2 0.79
<TS 1573 B
124 95 18 VS2 0
<TS 1574 B
124 95 21 VS4
-0.82
<TS 1575 B
124 95 22 VS4 1.08
<TS 1576 B
124 97 13 06C 0.91
<TS 1577 B
124 105 13 06C 0.7
<TS 1578 B
124 117 24 04C 0.74
<TS 1579 B
124 117 10 06C
-0.92
<TS 1580 B
124 117 14 06C 0.78
<TS 1581 B
124 117 25 VS7
-0.17
<TS 1582 B
124 117 14 VS4 0.71
<TS 1583 B
124 119 15 08C
-0.15
<TS 1584 B
124 119 17 08C 0.81
<TS 1585 B
125 48 14 VS4 0.85
<TS 1586 B
125 48 15 VS6 0.87
<TS 1587 B
125 78 14 03H
-0.79
<TS 1588 B
125 82 14 05H
-0.91
<TS 1589 B
125 94 18 VS2
-0.65
<TS 1590 B
125 94 14 VS2
-0.17
<TS 1591 B
125 100 12 08C 0.76
<TS 1592 B
125 104 17 07H 0.86
<TS 1593 B
125 104 22 07C
-0.26
<TS 1594 B
125 112 23 02C 0.66
<TS 1595 B
125 114 15 03C 0.76
<TS 1596 B
125 116 19 VS4
-0.84
<TS 1597 B
126 55 16 02C 0.78
<TS 1598 B
126 55 14 06H 0.96
<TS 1599 B
126 61 14 VS1 0.89
<TS 1600 B
126 81 11 VS4
-0.75
<TS 1601 B
126 83 20 VS1
-0.21
<TS 1602 B
126 91 20 VS2 0
<TS 1603 B
126 91 12 VS4
-0.8
<TS 1604 B
126 95 18 VS4
-0.82
<TS 1605 B
126 95 18 VS6 1.1
<TS 1606 B
126 99 14 08C 0.76
<TS 1607 B
126 99 14 07C 0.74
<TS 1608 B
126 103 19 VS4 0.9
<TS Page D-31
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1609 B
126 115 21 02C 0.8
<TS 1610 B
126 115 11 02C 0.07
<TS 1611 B
127 52 10 01H
-0.09
<TS 1612 B
127 54 23 01H
-0.78
<TS 1613 B
127 72 12 05H 0.87
<TS 1614 B
127 92 12 VS6
-0.8
<TS 1615 B
127 92 21 08C
-0.22
<TS 1616 B
127 102 17 07C
-0.28
<TS 1617 B
127 104 14 06C 0.78
<TS 1618 B
127 106 20 07C
-0.22
<TS 1619 B
127 112 14 02C 0.74
<TS 1620 B
127 114 19 01H
-0.83
<TS 1621 B
127 114 17 02C 0.76
<TS 1622 B
127 114 15 03C 0.78
<TS 1623 B
128 53 16 01H
-0.11
<TS 1624 B
128 55 22 01C
-0.59
<TS 1625 B
128 73 11 06H 0.11
<TS 1626 B
128 73 15 06H 0.94
<TS 1627 B
128 73 25 VS1 0.16
<TS 1628 B
128 73 16 VS4 1.01
<TS 1629 B
128 99 15 07C 0.76
<TS 1630 B
128 101 23 05C 0.73
<TS 1631 B
128 113 26 02C
-1
<TS 1632 B
129 56 20 01H 0.92
<TS 1633 B
129 58 13 01H
-0.69
<TS 1634 B
129 64 10 VS?
-0.78
<TS 1635 B
129 68 13 02H
-0.82
<TS 1636 B
129 84 20 06H 0.88
<TS 1637 B
129 102 10 08C 0
<TS 1638 B
129 102 22 08C
-0.98
<TS 1639 B
129 104 15 07C
-0.22
<TS 1640 B
129 106 21 08C 0.84
<TS 1641 B
129 110 19 02C 0.74
<TS 1642 B
130 55 23 01H 0.94
<TS 1643 B
130 55 18 02C 0.76
<TS 1644 B
130 65 11 VS2
-0.14
<TS 1645 B
130 65 17 VS4 0.69
<TS 1646 B
130 65 28 VS?
0.99
<TS 1647 B
130 69 12 05H 0.91
<TS 1648 B
130 79 13 VS2
-0.85
<TS 1649 B
130 91 23 DBC 1.63
<TS 1650 B
131 58 32 01C 0.7
<TS 1651 B
131 60 18 VS6 0.8
<TS 1652 B
131 64 29 VS?
0.99
<TS 1653 B
131 70 14 03C 0.78
<TS 1654 B
131 78 16 VS6
-0.79
<TS 1655 B
131 82 19 08H
-0.82
<TS 1656 B
131 96 20 04C 0.73
<TS 1657 B
131 98 32 VS6 0.97
<TS 1658 B
131 98 13 DBC 1.62
<TS 1659 B
131 98 31 VS?
0.58
<TS 1660 B
131 102 23 06C
-1.02
<TS Page D-32
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1661 B
131 102 19 05C 0.7
<TS 1662 B
131 102 14 04C 0.76
<TS 1663 B
131 104 31 VS7 0.94
<TS 1664 B
131 104 20 DBC 1.78
<TS 1665 B
131 108 14 07H
-0.94
<TS 1666 B
132 61 12 01H 0.98
<TS 1667 B
132 75 12 02H 0.87
<TS 1668 B
132 81 16 05H 0.92
<TS 1669 B
132 91 14 DBC 1.66
<TS 1670 B
132 97 9
VS1 0.93
<TS 1671 B
132 97 17 VS2
-0.67
<TS 1672 B
132 97 12 VS4
-0.95
<TS 1673 B
132 97 22 VS7 0.99
<TS 1674 B
132 101 18 06C 0.74
<TS 1675 B
132 101 15 06C
-0.2
<TS 1676 B
132 107 26 02C
-1.03
<TS 1677 B
133 68 15 02H 0.93
<TS 1678 B
133 74 15 03H 0.85
<TS 1679 B
133 76 16 07C 0.86
<TS 1680 B
133 100.
25 VS7 0
<TS 1681 B
133 102 14 VS7
-0.74
<TS 1682 B
133 102 16 07C
-1.04
<TS 1683 B
133 104 16 VS7 0.97
<TS 1684 B
133 104 11 DBC 1.64
<TS 1685 B
134 63 19 DBH
-1.79.
<TS 1686 B
134 63 15 07C 0.74
<TS 1687 B
134 65 11 VS2
-0.67
<TS 1688 B
134 65 20 02H 0.84
<TS 1689 B
134 69 26 VS7 0.96
<TS 1690 B
134 69 18 04H 0.94
<TS 1691 B
134 95 18 DBC 1.66
<TS 1692 B
134 97 15 VS6
-0.86
<TS 1693 B
134 97 18 VS6 0.86
<TS 1694 B
134 99 11 VS4
-0.87
<TS 1695 B
134 99 12 VS6
-0.89
<TS 1696 B
134 99 23 VS6 0.93
<TS 1697 B
134 101 24 VS7 0.99
<TS 1698 B
135 68 20 VS7 0.85
<TS 1699 B
135 72 19 VS7
-0.87
<TS 1700 B
135 76 13 06H 0.87
<TS 1701 B
135 76 18 VS7
-0.79
<TS 1702 B
135 76 18 08C 0.79
<TS 1703 B
135 76 20 08C
-1.02
<TS 1704 B
135 80 17 07H
-0.86
<TS 1705 B
135 82 24 VS7
-0.8
<TS 1706 B
135 82 29 VS7 0.94
<TS 1707 B
135 90 31 VS7 0.6
<TS 1708 B
135 92 27 07C O.S5
<TS 1709 B
135 92 36 08C 1.01
<TS 1710 B
135 92 38 VS7
-0.66
<TS 1711 B
135 94 27 DBC 1.75
<TS 1712 B
135 96 11 04C 0.76
<TS Page D-33
A Document No.: 51-9252894-001 AREVA Palisades 180-Day Steam Generator Tube Inspection Report for 1 R24 1713 8
135 98 12 VS6
-0.73
<TS 1714 8
136 69 19 DBC 1.88
<TS 1715 B
136 77 17 03H 0.89
<TS 1716 B
136 87 16 08C
-1.11
<TS 1717 B
136 91 20 DBC 1.86
<TS 1718 B
136 95 20 03C 0.72
<TS 1719 B
136 97 30 VS?
-0.73
<TS 1720 B
136 97 16 VS?
0.95
<TS 1721 B
136 97 14 08C
-0.04
<TS 1722 B
136 97 18 08C
-1.05
<TS 1723 8
136 97 14 07C 0.75
<TS 1724 8
136 97 17 03C 0.85
<TS 1725 8
137 74 16 06H 0.78
<TS 1726 8
137 76 14 05H 0.88
<TS 1727 B
137 78 12 03H
-0.73
<TS 1728 B
137 80 20 08H 0.86
<TS 1729 B
137 90 22 DBH 1.79
<TS 1730 B
137 90 12 VS1
-0.82
<TS 1731 B
137 90 16 VS4 0.24
<TS 1732 B
137 90 15 VS4 0.86
<TS 1733 B
137 90 15 VS6
-0.52
<TS 1734 8
137 90 22 VS?
-0.82
<TS 1735 8
137 90 18 VS?
0.93
<TS 1736 B
137 90 16 DBC 1.81
<TS 1737 8
137 92 22 VS?
-0.58
<TS 1738 8
137 92 19 08C
-1.05
<TS 1739 8
137 92 17 07C 0.04
<TS 1740 B
138 75 9
08H
-0.14
<TS 1741 B
138 77 19 02H 0.93
<TS 1742 8
138 77 12 03H
-0.82
<TS 1743 B
138 77 22 VS4 0.77
<TS 1744 B
138 79 16 03H 0.92
<TS 1745 B
138 79 30 VS1
-0.67
<TS 1746 B
138 79 24 VS2 0.74
<TS 1747 B
138 79 21 VS4 0.88
<TS 1748 B
138 79 21 VS6
-0.86
<TS 1749 B
138 79 22 VS6 0.88
<TS 1750 B
138 81 22 VS4
-0.86
<TS 1751 B
138 81 15 08C
-1.12
<TS 1752 B
138 85 15 08H 0.8
<TS 1753 B
138 85 28 DBH 1.9
<TS 1754 B
138 87 20 VS1
-0.82
<TS 1755 B
138 87 14 VS1 0.97
<TS 1756 B
138 87 18 VS4
-0.62
<TS 1757 B
138 89 19 VS4
-0.58
<TS 1758 B
138 89 15 VS6 0.8
<TS 1759 B
138 89 18 VS?
-0.82
<TS 1760 B
138 89 30 VS?
0.86
<TS 1761 B
138 89 15 O?C 0.72
<TS 1762 B
138 91 18 DBH 1.94
<TS Page D-34