PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 PSEG Nuclear LLC Technical Specification 6.9.1.5.b LR-N16-0010 FEB 2 5 2016 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Hope Creek Generating Station Renewed Facility Operating License No. NPF-57 NRC Docket No. 50-354

Subject:

Technical Specification 6.9.1.5.b 2015 Annual Report of SRV Challenges This report is being submitted in accordance with Hope Creek Technical Specification 6.9.1.5.b, which requires the documentation of all challenges to main steam line safety/relief valves (SRVs) be provided on an annual basis.

For 2015, the SRVs were not challenged by any over pressurization events or transients that would have required the valves to respond automatically.

There are no regulatory commitments contained in this letter.

Should you have any questions, please contact Mr. Philip Duca at 856-339-1640.

Sincerely, nneth Grover a'nager- Hope Creek pjd

Technical Specification 6.9.1.5.b LR-N16-0010 Page 2 cc: Mr. Daniel Dorman, Regional Administrator - Region 1 Nuclear Regulatory Commission Ms. Carleen Parker, Project Manager Hope Creek USNRC Mr. Justin Hawkins, NRC Senior Resident Inspector - Hope Creek (X24)

Mr. Thomas MacEwen, Hope Creek Commitment Coordinator (H02)

Mr. Lee Marabella, Corporate Commitment Coordinator (N21)

PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 PSEG Nuclear LLC Technical Specification 6.9.1.5.b LR-N16-0010 FEB 2 5 2016 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Hope Creek Generating Station Renewed Facility Operating License No. NPF-57 NRC Docket No. 50-354

Subject:

Technical Specification 6.9.1.5.b 2015 Annual Report of SRV Challenges This report is being submitted in accordance with Hope Creek Technical Specification 6.9.1.5.b, which requires the documentation of all challenges to main steam line safety/relief valves (SRVs) be provided on an annual basis.

For 2015, the SRVs were not challenged by any over pressurization events or transients that would have required the valves to respond automatically.

There are no regulatory commitments contained in this letter.

Should you have any questions, please contact Mr. Philip Duca at 856-339-1640.

Sincerely, nneth Grover a'nager- Hope Creek pjd

Technical Specification 6.9.1.5.b LR-N16-0010 Page 2 cc: Mr. Daniel Dorman, Regional Administrator - Region 1 Nuclear Regulatory Commission Ms. Carleen Parker, Project Manager Hope Creek USNRC Mr. Justin Hawkins, NRC Senior Resident Inspector - Hope Creek (X24)

Mr. Thomas MacEwen, Hope Creek Commitment Coordinator (H02)

Mr. Lee Marabella, Corporate Commitment Coordinator (N21)