vb U.S. NUCLEAR REGULATORY COMMISSION November 2015 OFFICE OF NUCLEAR REGULATORY RESEARCH Division 4 DRAFT REGULATORY GUIDE Technical Lead Thomas J. Nicholson This regulatory guide is being issued in draft form to involve the public in the development of regulatory guidance in this area. It has not received final staff review or approval and does not represent an NRC final staff position. Public comments are being solicited on this draft guide and its associated regulatory analysis. Comments should be accompanied by appropriate supporting data. Comments may be submitted through the Federal rulemaking Web site, http://www.regulations.gov, by searching for Docket ID <INSERT: NRC-20YY-XXXX>.

Alternatively, comments may be submitted to the Rules, Announcements, and Directives Branch, Office of Administration, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001. Comments must be submitted by the date indicated in the Federal Register notice.

Electronic copies of this draft regulatory guide, previous versions of this guide, and other recently issued guides are available through the NRCs public Web site under the Regulatory Guides document collection of the NRC Library at http://www.nrc.gov/reading-rm/doc-collections/reg-guides/. The draft regulatory guide is also available through the NRCs Agencywide Documents Access and Management System (ADAMS) at http://www.nrc.gov/reading-rm/adams.html, under Accession No. ML15287A388. The regulatory analysis may be found in ADAMS under Accession No. ML15287A385.

DRAFT REGULATORY GUIDE DG-4025 (Proposed New Regulatory Guide)

ASSESSMENT OF RADIOACTIVE DISCHARGES IN GROUND WATER TO THE UNRESTRICTED AREA AT NUCLEAR POWER PLANT SITES A.

INTRODUCTION Purpose This regulatory guide (RG) describes an approach that the U.S. Nuclear Regulatory Commission (NRC) staff considers acceptable for use in assessing abnormal, inadvertent radioactive releases which may result in discharges of contaminated ground water from the subsurface to the unrestricted area at commercial nuclear power plant sites.

Applicability This guide is applicable to Title 10 of the Code of Federal Regulations (10 CFR), Part 20, Standards for Protection against Radiation (Ref. 1), 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, (Ref. 2), 10 CFR Part 52 Licenses, Certifications, and Approvals for Nuclear Power Plants (Ref. 3), and 10 CFR Part 100, Reactor Site Criteria (Ref. 4).

Applicable Regulations Title 10 of the Code of Federal Regulations (10 CFR), Part 20, Standards for Protection against Radiation, provides standards for protection against ionizing radiation resulting from activities conducted under licenses issued by the NRC.

10 CFR 20.1406(a) requires that applicants for licenses other than early site permits and manufacturing licenses under 10 CFR Part 52, whose applications are submitted after August 20, 1997, describe in the application how facility design and procedures for operation will minimize, to the extent practicable, contamination of the facility and the environment, facilitate eventual decommissioning, and minimize, to the extent practicable, the generation of radioactive waste.

DG-4025, Page 2 10 CFR 20.1406(b) requires that applicants for standard design certifications, standard design approvals, and manufacturing licenses under 10 CFR Part 52, whose applications are submitted after August 20, 1997, describe in the application, how facility design will minimize, to the extent practicable, contamination of the facility and the environment, facilitate eventual decommissioning, and minimize, to the extent practicable, the generation of radioactive waste.

10 CFR 20.1406(c) requires that licensees to the extent practical, conduct operations to minimize the introduction of residual radioactivity into the site, including the subsurface, in accordance with the existing radiation protection requirements in Subpart B and radiological criteria for license termination in Subpart E of this part.

10 CFR 20.1501 requires that licensees perform surveys of areas, including the subsurface, that are reasonable to evaluate the magnitude and extent of concentrations or quantities of residual radioactivity, and determine the potential radiological hazards of the radiation levels and residual radioactivity detected.

10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, provides for the licensing of nuclear power plants.

10 CFR 50.36(a)(2) requires that licensees report the quantity of each of the principal radionuclides released to unrestricted areas from liquid and gaseous effluents during the previous 12 months, including any other information as may be required by the Commission to estimate maximum potential annual radiation doses to the public resulting from effluent releases.

10 CFR Part 50 Appendix A provides general design criteria (GDC) for nuclear power plants.

The following GDCs are of importance to the radioactive releases to ground water:

GDC 60, Control of Releases of Radioactive Materials to the Environment, states, the nuclear power unit design shall include means to control suitably the release of radioactive materials in gaseous and liquid effluents and to handle radioactive solid wastes produced during normal reactor operation, including anticipated operational occurrences. Sufficient holdup capacity shall be provided for retention of gaseous and liquid effluents containing radioactive materials, particularly where unfavorable site environmental conditions can be expected to impose unusual operational limitations upon the release of such effluents to the environment.

GDC 64, Monitoring Radioactivity Releases, requires that a means shall be provided for monitoring, among other things, the facility environs for radioactivity that may be released from normal operations, including anticipated operational occurrences, and from postulated accidents.

10 CFR Part 52 Licenses, Certifications, and Approvals for Nuclear Power Plants, provides for the licensing of early site permits, standard design certifications and combined licenses for nuclear power plants.

10 CFR 52.47(a)(6) requires that the Final Safety Analysis Report (FSAR) includes the information in 10 CFR 20.1406.

DG-4025, Page 3 10 CFR 52.47(a)(22) requires that the FSAR includes the information to demonstrate how operating insights has been incorporated into the plant design.

10 CFR Part 100, Reactor Site Criteria, requires the NRC to consider population density; use of the site environs, including proximity to manmade hazards; and the physical characteristics of a site, including seismology, meteorology, geology, and hydrology, in determining the sites acceptability for a nuclear power reactor.

100.20(c)(3) requires that factors important to hydrological radionuclide transport (such as soil, sediment and rock characteristics, adsorption and retention coefficients, ground water velocity, and distances to the nearest surface body of water) must be obtained from on-site measurements.

Related Guidance RG 1.21, Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste (Ref. 5), contains information on the monitoring of leaks and spills, as well as controlled releases.

RG 4.1, Radiological Environmental Monitoring for Nuclear Power Plants (Ref. 6), provides a method considered acceptable for use in establishing and conducting an environmental monitoring program at nuclear power plants. In particular, it describes guidance on the establishment of a radiological environmental monitoring program (REMP), which involves measuring the levels of radiation and radioactive materials in the local environment (including the subsurface) during the lifetime of the facility.

RG 4.21, Minimization of Contamination and Radioactive Waste Generation: Life-Cycle Planning (Ref. 7), provides guidance on meeting the requirements of 10 CFR 20.1406, Minimization of Contamination. Regulatory Position C.2 of RG 4.21 focuses on gathering sufficient information to support the development of a conceptual site model and in planning design features for the early detection of leakage and migration of radioactivity in soils and ground and surface water.

RG 4.22, Decommissioning Planning During Operations (Ref. 8), provides guidance to licensees who are required to minimize contamination and radioactive waste generation, conduct appropriate radiological surveys including the subsurface, maintain records of residual radioactivity, and provide adequate funding to complete decommissioning in accordance with portions of the Decommissioning Planning Rule, namely, 10 CFR 20.1406 and 20.1501.

NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition (Ref. 9), Sections 2.4.12, on Ground Water and 2.4.13, on Accidental Releases of Radioactive Liquid Effluents in Ground and Surface Waters, provide guidance to NRC staff on review of an applicants submitted information for characterizing and assessing the ground water site conditions and scenarios for accidental releases (e.g., principally a leaking radwaste tank) at the site as well as potential offsite consequences. Section 11.2 addresses the Liquid Waste Management System, and BTP 11-6 covers Postulated Radioactive Releases Due to Liquid-Containing Tank Failures.

Design Certification/Combined License (DC/COL) Final Interim Staff Guidance (ISG)

DC/COL-ISG-06, Evaluation and Acceptance Criteria for 10 CFR 20.1406 to Support Design

DG-4025, Page 4 Certification and Combined License Applications (Ref. 10), provides interim guidance to DC and COL applicants and NRC staff for their analysis on how applicants have complied with the requirements of 10 CFR 20.1406. It provides interim guidance to supplement the evaluation and acceptance criteria found in FSAR Chapters 2, Site Characteristics and Site Parameters, 5, Reactor Coolant System and Connected Systems, 9, Auxiliary Systems, 10, Steam and Power Conversion System, 11, Radioactive Waste Management, 12, Radiation Protection, and 13, Conduct of Operations of NUREG-0800 and the guidance in RG 4.21.

DC/COL-ISG-013, Assessing the Radiological Consequences of Accidental Releases of Radioactive Materials from Liquid Waste Tanks for Combined License Applications (Ref. 11),

provides interim guidance to licensees and NRC staff for their analysis of the consequences of an accidental release with an emphasis on how radiological consequences are determined. It provides specific interim guidance on implementing Sections 2.4.12, 2.4.13, 11.2, and BTP 11-6 of NUREG-0800.

DC/COL-ISG-014, Assessing the Radiological Consequences of Accidental Releases of Radioactive Materials from Liquid Waste Tanks in Ground and Surface Waters for Combined License Applications (Ref. 12), provides interim guidance to licensees and NRC staff on analyzing the accidental releases of radioactivity in ground and surface water. It emphasizes the consideration of hydrogeologic conditions that control the transport of radioactive materials and provides specific interim guidance on implementing Sections 2.4.12, 2.4.13, 11.2, and BTP 11-6 of NUREG-0800.

NUREG/CR-6948, Volume 1, Integrated Ground-Water Monitoring Strategy for NRC Licensed Facilities and Sites: Logic, Strategic Approach and Discussion (Ref. 13), presents a framework for assessing what, how, where and when to monitor ground water to ensure that a licensed nuclear site or facility is within regulatory limits.

Purpose of Regulatory Guides The NRC issues RGs to describe to the public methods that the staff considers acceptable for use in implementing specific parts of the agencys regulations, to explain techniques that the staff uses in evaluating specific problems or postulated events, and to provide guidance to applicants. Regulatory guides are not substitutes for regulations and compliance with them is not required. Methods and solutions that differ from those set forth in RGs will be deemed acceptable if they provide a basis for the findings required for the issuance or continuance of a permit or license by the Commission.

Paperwork Reduction Act This regulatory guide contains and references information collections covered by 10 CFR Parts 20, 50, 52, and 100 that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.).

These information collections were approved by the Office of Management and Budget (OMB), control numbers 3150-0014, 3150-0011, 3150-0151, and 3150-0093.

Public Protection Notification The NRC may neither conduct nor sponsor, and a person is not required to respond to, an information collection request or requirement unless the requesting document displays a currently valid OMB control number.

DG-4025, Page 5 B. DISCUSSION Reason for Issuance Discharges of liquid effluents through surface waters are normally monitored and reported as described in RG 1.21; however, discharges through ground water pathways have not been a routinely monitored pathway. This RG provides guidance on how to determine liquid effluent discharges through the ground water pathway.

=

Background===

As plants began to undergo decommissioning in the late 1990s to early 2000s, instances of subsurface and/or ground water contamination were identified. Several operating facilities also identified ground water contamination resulting from spills and leaks or equipment failure. In one instance, low levels of licensed material were detected in a private well located on property adjacent to a nuclear power plant. The source of these releases included a wide range of structures, systems and components important to safety (SSCs), such as condensate storage tanks, spent fuel pools, vacuum breaker valves along circulating blowdown lines, and buried pipe leaks. The principal radionuclide released was hydrogen-3 (tritium). Other radionuclides released include strontium-90, cesium-137, nickel-63, cobalt-60, and antimony-125, depending upon the source. Although the releases were not a significant public health issue, they needed to be addressed.

In March 2006, the NRC formed the Liquid Radioactive Release Lessons Learned Task Force (LLTF) to evaluate the liquid radioactive releases and to make recommendations. The task force summarized the result of its evaluation in September 2006 and offered recommendations for addressing the inadvertent releases to the subsurface (Ref. 14). Among them was a recommendation (3.5.4) that NRC should consider the development of guidance for evaluating radionuclide transport in ground water.

It went on to note that ANSI/ANS 2.17-1980 provided guidance and that it was being extensively updated at that time. The update was released for use as ANSI/ANS 2.17-2010 (Ref. 15).

Industry took action to address inadvertent abnormal releases of radioactivity in ground water. In August 2007, the Nuclear Energy Institute (NEI) issued NEI 07-07 Industry Ground Water Protection Initiative (GPI)-Final Guidance Document (Ref. 16). Subsequently, all operating and decommissioning power plants adopted the initiative. The program involves development of a ground water site model; onsite ground water monitoring, which includes installation of monitoring wells; and a remediation process and reporting requirements. To determine if the commitments set forth in NEI 07-07 were implemented, NRC issued NRC Inspection Manual/Temporary Instruction 2515/173, Revision 1, Review of the Implementation of the Industry Ground Water Protection Voluntary Initiative, (Ref. 17).

The Electric Power Research Institute (EPRI) provided NEI supporting guidance for the ground water protection initiative. In 2005 it issued EPRI Report 1011730, Groundwater Monitoring Guidance for Nuclear Power Plants, (Ref. 18), and in 2007 it issued EPRI Report 1015118, Groundwater Protection Guidelines for Nuclear Power Plants, (Ref. 19).

In October 2009, NEI issued NEI-08-08A, Revision 0, Generic FSAR Template Guidance for Life Cycle Minimization of Contamination (Ref. 20). NEI 08-08A applies to applicants for licenses whose applications are submitted after August 20, 1997, under 10 CFR 52 Subpart C. NEI 08-08A describes an operational program to minimize contamination throughout the life-cycle of a facility, including provisions for minimizing facility contamination, environmental contamination, waste generation, and facilitating decommissioning. EPRI provided NEI supporting guidance for a ground water protection program. In 2008, it issued EPRI Report 1016099, Ground Water Protection

DG-4025, Page 6 Guidelines for Nuclear Power Plants (Ref. 21). EPRI Report 1016099 and NEI 07-07 provide the technical basis in NEI 08-08A. NEI 08-08A provides an acceptable approach for an effective ground water protection program that meets the requirements of 10 CFR 20.1406 with verification of the program during the construction stage for licenses under 10 CFR Part 52 Subpart C.

In April 2013, NEI issued NEI 09-14, Revision 3, Guideline for the Management of Underground Piping and Tank Integrity (Ref. 22). NEI 09-14 describes the policy and practices that the industry commits to follow in managing underground piping and tanks, and compliments NEI 07-07.

EPRI Technical Report 1016456, Revision 1, Recommendations for an Effective Program to Control the Degradation of Buried and Underground Piping and Tanks, (Ref. [23) provides implementation guidance for NEI 09-14. To determine if the commitments set forth in NEI 09-14 were implemented, NRC issued NRC Inspection Manual/Temporary Instruction 2515/182, Review of the Implementation of the Industry Initiative to Control Degradation of Underground Piping and Tanks, Ref. 24).

Harmonization with International Standards The International Atomic Energy Agency (IAEA) has established a series of safety guides and standards constituting a high level of safety for protecting people and the environment. IAEA safety guides present international good practices and increasingly reflects best practices to help users striving to achieve high levels of safety. Pertinent to this regulatory guide IAEA-TECDOC-482, Prevention and Mitigation of Groundwater Contamination from Radioactive Releases (Ref. 25), discusses the characteristics of the releases (primarily for two scenarios, namely an underground storage tank, and a severe reactor core accident); modeling of radionuclide movement in the subsurface; prevention and mitigation techniques; monitoring and sampling; and quality assurance and quality control. The document also includes an appendix of suggested ground water models developed in the early 1980s for both unsaturated and saturated flow conditions. A related IAEA safety standard, WS-G-3.1, Remediation Process for Areas Affected by Past Activities and Accidents (Ref.26), briefly describes site characterization, setting remediation criteria, and establishing remediation planning and implementation. This RG is consistent with the basic safety principles provided by these two IAEA guides.

Documents Discussed in Staff Regulatory Guidance This RG endorses the use of one or more codes or standards developed by external organizations, and other third party guidance documents. These codes, standards and third party guidance documents may contain references to other codes, standards or third party guidance documents (secondary references). If a secondary reference has itself been incorporated by reference into NRC regulations as a requirement, then licensees and applicants must comply with that standard as set forth in the regulation. If the secondary reference has been endorsed in an RG as an acceptable approach for meeting an NRC requirement, then the standard constitutes a method acceptable to the NRC staff for meeting that regulatory requirement as described in the specific RG. If the secondary reference has neither been incorporated by reference into NRC regulations nor endorsed in an RG, then the secondary reference is neither a legally binding requirement nor a generic NRC-approved acceptable approach for meeting an NRC requirement. However, licensees and applicants may consider and use the information in the secondary reference, if appropriately justified, consistent with current regulatory practice, and consistent with applicable NRC requirements.

DG-4025, Page 7 C. STAFF REGULATORY GUIDANCE ANSI/ANS 2.17-2010 provides an acceptable method for assessing radioactive discharges in ground water to the unrestricted area at nuclear power plant sites. While the standard does not provide a specific model, it provides a graded, risk-informed approach for evaluating the effects of subsurface radionuclide transport. The approach is based on the complexity of geologic and hydrologic conditions, the types of radioactive materials and facility design, the types and effectiveness of engineered and natural barriers, and the proximity to surface water and ground water receptors. A facility that has less significant radionuclide source term, minor subsurface contamination, simple or well-understood hydrogeology, or limited effects on ground water resources generally requires less extensive site characterization, mathematical modeling, and performance-confirmation measures than a facility with significant subsurface contamination that has the potential to exceed national radiation protection standards.

The appendix to this guide provides a simple ground water flow and transport model acceptable for estimating offsite tritium activity flux at nuclear power plant sites. It is similar to those found in Interstate Technology & Regulatory Council (ITRC), Use and Measurement of Mass Flux and Mass Discharge (Ref. 27), and American Petroleum Institute (API) Publication Number 4730, Groundwater Remediation Strategies Tool (Ref. 28). It is intended for use with simple hydrogeologic conditions and geometry such as steady-state flow in homogeneous porous sand layers. The model is provided in a spreadsheet format to facilitate identification of model input and output and is available in ADAMS as Accession No. ML15086A566. In this simple model, a transect area is constructed perpendicular to the general ground water flow direction, and is divided into subareas as determined from the hydrogeologic unit heterogeneity; ground water flow conditions; and monitoring-well data. The total activity flux of the contaminant(s) through the transect cross-section is approximated as the sum over all subareas of the product of the contaminant concentration, the subarea specific discharge, and the flow area (see Equation A3).

The model in the appendix is an acceptable approach at a simple site for estimating ground water discharges based on ground water flow and transport. An example of a simple site is one that can be modeled as homogeneous or as a simple layering of homogenous hydrogeologic units where ground water flow can be represented as uniform and steady state. In contrast, a complex site may exhibit features such as highly heterogeneous hydrogeologic units or preferential flow paths. Another feature indicating a complex site is non-uniform or transient ground water flow conditions. This may be caused by processes such as variable recharge, tidal fluctuations, and/or nearby water-well pumping. If the site complexity and radionuclide release scenario do not permit simple analysis, the model should be adjusted to account for site specific characteristics using the guidance set forth in ANSI/ANS-2.17-2010.

DG-4025, Page 8 D. IMPLEMENTATION The purpose of this section is to provide information on how applicants and licensees1 may use this guide and information about the NRCs plans for using this regulatory guide. In addition, it describes how the NRC staff complies with 10 CFR 50.109, Backfitting and any applicable finality provisions in 10 CFR Part 52, Licenses, Certifications, and Approvals for Nuclear Power Plants.

Use by Applicants and Licensees Applicants and licensees may voluntarily2 use the guidance in this document to demonstrate compliance with the underlying NRC regulations. Methods or solutions that differ from those described in this regulatory guide may be deemed acceptable if they provide sufficient basis and information for the NRC staff to verify that the proposed alternative demonstrates compliance with the appropriate NRC regulations. Current licensees may continue to use guidance the NRC found acceptable for complying with the identified regulations as long as their current licensing basis remains unchanged.

Licensees may use the information in this regulatory guide for actions that do not require NRC review and approval, such as changes to a facility design under 10 CFR 50.59, Changes, Tests, and Experiments. Licensees may use the information in this regulatory guide or applicable parts to resolve regulatory or inspection issues.

Use by NRC Staff The NRC staff does not intend or approve any imposition or backfitting of the guidance in this regulatory guide. The NRC staff does not expect any existing licensee to use or commit to using the guidance in this regulatory guide, unless the licensee makes a change to its licensing basis. The NRC staff does not expect or plan to request licensees to voluntarily adopt this regulatory guide to resolve a generic regulatory issue. The NRC staff does not expect or plan to initiate NRC regulatory action which would require using this regulatory guide. Examples of such unplanned NRC regulatory actions include issuance of an order requiring using the regulatory guide, requests for information under Title 10 of the Code of Federal Regulations (10 CFR) 50.54(f) as to whether a licensee intends to commit to use of this regulatory guide, generic communication, or promulgation of a rule requiring using this regulatory guide without further backfit consideration.

During regulatory discussions on plant-specific operational issues, the staff may discuss with licensees various actions consistent with staff positions in this regulatory guide, as one acceptable means of meeting the underlying NRC regulatory requirement. Such discussions would not ordinarily be considered backfitting even if prior versions of this regulatory guide are part of the licensing basis of the facility. However, unless this regulatory guide is part of the licensing basis for a facility, the staff may not represent to the licensee that the licensees failure to comply with the positions in this regulatory guide constitutes a violation.

If an existing licensee voluntarily seeks a license amendment or change and (1) the NRC staffs consideration of the request involves a regulatory issue directly relevant to this new or revised regulatory guide and (2) the specific subject matter of this regulatory guide is an essential consideration in the staffs determination of the acceptability of the licensees request, then the staff may request that the licensee 1

In this section, licensees refers to licensees of nuclear power plants under 10 CFR Parts 50 and 52; and the term applicants, refers to applicants for licenses and permits for (or relating to) nuclear power plants under 10 CFR Parts 50 and 52, and applicants for standard design approvals and standard design certifications under 10 CFR Part 52.

2 In this section, voluntary and voluntarily means that the licensee is seeking the action of its own accord, without the force of a legally binding requirement or an NRC representation of further licensing or enforcement action.

DG-4025, Page 9 either follow the guidance in this regulatory guide or provide an equivalent alternative process that demonstrates compliance with the underlying NRC regulatory requirements. This is not considered backfitting as defined in 10 CFR 50.109(a) (1) or a violation of any of the issue finality provisions in 10 CFR Part 52.

Additionally, an existing applicant may be required to comply with new rules, orders, or guidance if 10 CFR 50.109(a) (3) applies.

If a licensee believes that the NRC is either using this regulatory guide or requesting or requiring the licensee to implement the methods or processes in this regulatory guide in a manner inconsistent with the discussion in this Implementation section, then the licensee may file a backfit appeal with the NRC in accordance with the guidance in and the NRC Management Directive 8.4, Management of Facility-Specific Backfitting and Information Collection (Ref. 29), and NUREG-1409, Backfitting Guidelines (Ref. 30).

DG-4025, Page 10 GLOSSARY abnormal release The unplanned or uncontrolled emission of an effluent (i.e., containing plant-related, licensed radioactive material (RG 1.21).

accessible environment Outside the controlled area, notably the atmosphere; the land surface; surface water; oceans; and that portion of the lithosphere (including ground water).

contaminant Any physical, chemical, biological, or radiological substance or matter that has an adverse effect on air, water, or soil quality.

controlled discharge A radioactive discharge is considered to be controlled if (1) the discharge was conducted in accordance with methods, and without exceeding any of the limits, outlined in the offsite dose calculation manual, or (2) if one or more of the following three items are true:

1.

The radioactive discharge had an associated, planned method of radioactivity monitoring that assured the discharge was properly accounted and was within the limits set by 10 CFR 20 and 10 CFR 50.

2.

The radioactive discharge had an associated, planned method of termination (and associated termination criteria) that assured the discharge was properly accounted and was within the limits set by 10 CFR 20 and 10 CFR 50.

3.

The radioactive discharge had an associated, planned method of adjusting, modulating, or altering the flow rate (or the rate of release of radioactive material) that assured the discharge was properly accounted and was within the limits set by 10 CFR 20 and 10 CFR 50 (RG 1.21).

discharge point A location at which radioactive material enters the unrestricted area. This would be the point beyond the vertical plane of the unrestricted area (surface or subsurface)

(RG 1.21).

flux The volumetric or mass discharge per unit cross-sectional area of medium over time (solids plus pores); called the Darcian flux when applied to water movement (ANSI/ANS 2.17-2010).

ground water All water in the surface soil, the subsurface soil, or any other subsurface water.

Ground water is simply water in the ground regardless of its quality, including saline, brackish, or fresh water. Ground water can be moisture in the ground that is above the regional water table in the unsaturated (or vadose) zone, or ground water can be at and below the water table in the saturated zone (RG 1.21).

DG-4025, Page 11 residual radioactivity Residual radioactivity means radioactivity in structures, materials, soils, ground water, and other media at a site resulting from activities under the licensees control.

This includes radioactivity from all licensed and unlicensed sources used by the licensee, but it excludes background radiation. It also includes radioactive materials remaining at the site because of routine or accidental releases of radioactive material at the site and previous burials at the site, even if those burials were made in accordance with the provisions of 10 CFR Part 20.

uncontrolled discharge An effluent discharge that does not meet the definition of a controlled discharge. See the definition of controlled discharge (RG 1.21).

uncontrolled release An effluent release that does not meet the definition of a controlled release. See the definition of controlled release (RG 1.21).

unsaturated zone The zone immediately below the land surface where the pores contain both water and air, but are not totally saturated with water. These zones differ from an aquifer, where the pores are saturated with water. The unsaturated zone is synonymous with the vadose zone (U.S. Geological Survey Water Science Glossary, Ref. 31).

vadose zone See unsaturated zone.

DG-4025, Page 12 REFERENCES3

1.

U.S. Code of Federal Regulations (CFR), Standards for Protection against Radiation, Part 20, Chapter I, Title 10, Energy.

2.

CFR, Domestic Licensing of Production and Utilization Facilities, Part 50, Chapter I, Title 10, Energy.

3.

CFR, Licenses, Certifications, and Approvals for Nuclear Power Plants, Part 52, Chapter I, Title 10, Energy.

4.

CFR, Reactor Site Criteria, Part 100, Chapter I, Title 10, Energy.

5.

U.S. Nuclear Regulatory Commission (NRC), Regulatory Guide (RG) 1.21, Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste, Washington, DC.

6.

NRC, RG 4.1, Radiological Environmental Monitoring For Nuclear Power Plants, Washington, DC.

7.

NRC, RG 4.21, Minimization of Contamination and Radioactive Waste Generation: Life-Cycle Planning, Washington, DC.

8.

NRC, RG 4.22, Decommissioning Planning During Operations, Washington, DC.

9.

NRC, NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition, Washington, DC.

10.

NRC, Design Certification/Combined License (DC/COL)-Final Interim Staff Guidance (ISG)-06, Evaluation and Acceptance Criteria for 10 CFR 20.1406 to Support Design Certification and Combined License Applications, Washington, DC, October 2009. (ADAMS Accession No. ML092470100)

11.

NRC, DC/COL-ISG-013, Assessing the Radiological Consequences of Accidental Releases of Radioactive Materials from Liquid Waste Tanks for Combined License Applications, Washington, DC, January 2013. (ADAMS Accession No. ML12191A325)

12.

NRC, DC/COL-ISG-014, Assessing the Radiological Consequences of Accidental Releases of Radioactive Materials from Liquid Waste Tanks in Ground and Surface Waters for Combined License Applications, Washington, DC, January 2013. (ADAMS Accession No. ML12191A330)

13.

NRC, NUREG/CR-6948, Integrated Ground-Water Monitoring Strategy for NRC Licensed Facilities and Sites: Logic, Strategic Approach and Discussion, November 2007.

3 Publicly available NRC documents are available electronically through the NRC Library on the NRCs public Web site at http://www.nrc.gov/reading-rm/doc-collections/ and through the NRCs Agencywide Documents Access and Management System (ADAMS) at http://www.nrc.gov/reading-rm/adams.html. The documents can also be viewed online or printed for a fee in the NRCs Public Document Room (PDR) at 11555 Rockville Pike, Rockville, MD. For problems with ADAMS, contact the PDR staff at 301-415-4737 or (800) 397-4209; or e-mail pdr.resource@nrc.gov.

DG-4025, Page 13

14.

NRC, Liquid Radioactive Release Lessons Learned Task Force (LLTF) Final Report, Washington, DC, September 1, 2006. (ADAMS No. ML ML062650312)

15.

American National Standards Institute/ American Nuclear Society (ANSI/ANS)-2.17-2010, Evaluation of Subsurface Radionuclide Transport at Commercial Nuclear Power Plants, La Grange Park, IL, December 2010.4

16.

Nuclear Energy Institute (NEI) NEI 07-07, Industry Ground Water Protection Initiative - Final Guidance Document, Nuclear Energy Institute, Washington, DC, August 2007.5 (ADAMS Accession No. ML072600295)

17.

NRC, Inspection Manual/Temporary Instruction 2515/173, Rev. 1, Review of the Implementation of the Industry Groundwater Protection Voluntary Initiative, Washington, DC, October 31, 2008. (ADAMS Accession No. ML082770349)

18.

Electric Power Research Institute (EPRI) Report 1011730, Groundwater Monitoring Guidance for Nuclear Power Plants, Palo Alto, CA, September 2005.6

19.

EPRI Report 1015118, Groundwater Protection Guidelines for Nuclear Power Plants, Electric Power Research Institute, Palo Alto, California, November 2007.

20.

NEI 08-08A, Revision 0, Generic FSAR Template Guidance for Life-Cycle Minimization of Contamination, Nuclear Energy Institute, Washington, DC, October 2009.5 (ADAMS Accession No. ML093220530)

21.

EPRI Report 1016099, Ground Water Protection Guidelines for Nuclear Power Plants, January 2008 (Public Edition).6 22 NEI-09-14 Revision 3, Guideline for the Management of Underground Piping and Tank Integrity, Nuclear Energy Institute, Washington, DC, April 2013.5 (ADAMS Accession No. ML13130A322) 23 EPRI Technical Report 1016456, Revision 1, Recommendations for an Effective Program to Control the Degradation of Buried and Underground Piping and Tanks,

24.

NRC Inspection Manual/Temporary Instruction 2515/182, Review of the Implementation of the Industry Initiative to Control Degradation of Underground Piping and Tanks, Washington, DC, August 8, 2013. (ADAMS Accession No. ML13114A318) 4 Copies of American National Standards Institute (ANSI) standards may be purchased from ANSI, 1819 L Street, NW, Washington, DC, 20036, on their Web site at: http://webstore.ansi.org/; telephone (202) 293-8020; fax (202) 293-9287; or e-mail storemanager@ansi.org.

5 Publications from the Nuclear Energy Institute (NEI) are available at their Web site: http://www.nei.org/ or by contacting the headquarters at Nuclear Energy Institute, 1776 I Street NW, Washington DC 20006-3708, Phone: 202-739-8000, Fax 202-785-4019.

6 Copies of Electric Power Research Institute (EPRI) documents may be obtained by contacting the Electric Power Research Institute, 3420 Hillview Avenue, Palo Alto, CA 94304, Telephone: 650-855-2000 or on-line at http://my.epri.com/portal/server.pt.

DG-4025, Page 14

25.

International Atomic Energy Agency (IAEA) TECDOC Series No. 482, Prevention and Mitigation of Ground-Water Contamination from Radioactive Releases, Vienna, Austria, 1988.7

26.

IAEA Safety Standard WS-G-3.1, Remediation Process for Areas Affected by Past Activities and Accidents, Vienna, Austria, 2007.

27.

Interstate Technology & Regulatory Council (ITRC), Use and Measurement of Mass Flux and Mass Discharge, Integrated DNAPL Site Strategy Team, Interstate Technology and Regulatory Council, August 2010.8

28.

American Petroleum Institute (API) Publication Number 4730, Groundwater Remediation Strategies Tool, Regulatory Analysis & Scientific Affairs Department, American Petroleum Institute, Product No. 147300, Washington, DC, December 2003.9

29.

NRC, Management Directive 8.4, Management of Facility-Specific Backfitting and Information Collection, Washington, DC.

30.

NRC, NUREG-1409, Backfitting Guidelines, Washington, DC.

31.

U.S. Geological Survey, USGS Water Science Glossary of Terms, Reston, VA, March 2015.

(see: http://water.usgs.gov/edu/dictionary.html) 7 Copies of International Atomic Energy Agency (IAEA) documents may be obtained through their Web site:

WWW.IAEA.Org/ or by writing the International Atomic Energy Agency, P.O. Box 100 Wagramer Strasse 5, A-1400 Vienna, Austria.

8 Publications of the Interstate Technology & Regulatory Council (ITRC) are available at their Web site:

http://www.itrcweb.org/.

9 Copies of American Petroleum Institute (API) standards may be purchased through their Web site at:

http://global.ihs.com/?RID=API1&MID=Q023 or by contacting API Headquarters at 1220 L Street, NW Washington, DC 20005-4070 USA Phone 202-682-8000, Web Site: http://www.api.org/ or E-Mail: standards@api.org.

DG-4025, Appendix Page 1 APPENDIX Simple Ground Water Model for Estimating Offsite Tritium Activity Flux This appendix provides a simple ground-water flow and transport model for estimating offsite tritium (Hydrogen-3) activity flux at commercial nuclear power plant sites. This model is provided in a spreadsheet format to facilitate identification of model inputs and outputs, and is in ADAMS at Accession No. ML15086A566).

The model building process is as follows:

1.

Develop a conceptual site model for the site as specified in ANSI/ANS-2.17-10.

2.

Assess the available site characterization and monitoring data to assist in constructing a transect (cross section) where the activity flux will be estimated.

3.

Construct a series of transects between the monitoring wells normal to the approximate direction of ground water flow leaving the site.

4.

Determine from the site characterization data how the hydrogeologic units can be represented.

For example, is there layering in the soil and geologic media, and how variable are the properties within each hydrogeologic unit (e.g., (K) the hydraulic conductivity)?

If so, discretize the transect to accommodate these variations and any hydrogeologic unit layering.

If not, are the hydrogeologic units sufficiently uniform in material properties to represent them as separate units with uniform hydraulic properties (e.g., hydraulic conductivity (K) and hydraulic gradient (I) normal to the transect)?

If so, represent the transect by a stack of blocks at each well location representing the layering at that location - each block will be the thickness of the layer that it represents.

If not, discretize the transect to accommodate these variations in hydraulic properties.

5.

Select the monitoring wells to be used in estimating the tritium flux into the unrestricted area as close to the sites boundary as possible given the available data (i.e., geologic borings and monitoring points or intervals)

6.

Determine, after reviewing the monitoring data, whether there is a basis to vary tritium concentrations with depth within a hydrogeologic unit.

If so, further discretize the hydrogeologic unit to accommodate these variations within the hydrogeologic unit layering.

If not, no further discretization is warranted.

DG-4025, Appendix, Page 2

7.

Once the discretization is complete:

a.

Determine hydraulic properties for each block (i.e., subarea in the transect).

b.

Calculate the specific discharge for each set of hydraulic properties (or each block) using the following equation:

equation A-1 where is the specific discharge perpendicular to block, in cubic feet/day per cross-sectional area measured in square feet; ultimately as ft/day is the hydraulic conductivity for the material in block, ft/day (obtained from site-specific hydraulic tests), and is the hydraulic gradient normal to block, ft/ft (dimensionless) (change in hydraulic head over distance to discharge point).

c.

Calculate the bulk water flux across each block in the discretization using the following equation:

Qw qA equation A-2 where is the bulk water flux for block, cubic feet/day, and is the area of block,

square ft.

d.

Determine tritium concentrations for each block and for each time period for which there is a tritium activity measurement.

e.

Calculate the tritium-activity flux across each block by multiplying the tritium activity concentration for each block by the bulk water flux for each block using the following equation:

QCQw equation A-3 where is the tritium activity flux for block, pCi/day; and is the tritium activity concentration of block, pCi/liter.

f.

Sum up for each time period (e.g., monthly), the tritium activity fluxes to obtain a total tritium-activity flux (e.g., total monthly tritium-activity flux for the transect).

8.

Average the totals if interested in an average activity flux across the transect for a longer time period (such as annual).

9.

To estimate the total tritium-activity discharging to the accessible environment, estimate the time of travel from the transect to the boundary of the accessible environment, and reduce the total tritium-activity discharge from radioactive decay for this incremental additional travel time.

DG-4025, Appendix Page 1 Table 1. Overview of the example Table 2. Plan view of the transect showing location of the facility, the transect, ground water flow direction and location of a large body of water

DG-4025, Appendix, Page 2

DG-4025, Appendix, Page 3 Table 3. Vertical transect illustrating the hydrostratigraphy and the location of the monitoring wells.

DG-4025, Appendix, Page 4 Table 4. Monitoring data showing tritium concentration

DG-4025, Appendix, Page 5 Table 5. Activity flux through each transect block [pCi/day]

DG-4025, Appendix, Page 6 Table 6. Total transect activity flux