Response to Second Request for Additional Information Regarding Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program
ML15205A341
Person / Time
Site: Millstone 
Issue date: 07/20/2015
From: Mark D. Sartain
Dominion, Dominion Nuclear Connecticut
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
15-342, TAC MF5096
Download: ML15205A341 (8)


Text

Dominion Nuclear Connecticut, Inc.

D 5.000 Dominion Boulevard, Glen Allen, VA 23060 D

Web Address: www.dom.com July 20, 2015 U.S. Nuclear Regulatory Commission Serial No.15-342 Attention: Document Control Desk NLOSIWDC RO Washington, DC 20555 Docket No.

50-336 License No.

DPR-65 DOMINION NUCLEAR CONNECTICUT, INC.

MILLSTONE POWER STATION UNIT 2 RESPONSE TO SECOND REQUEST FOR ADDITIONAL INFORMATION REGARDING RELOCATION OF SPECIFIC SURVEILLANCE FREQUENCY REQUIREMENTS TO A LICENSEE CONTROLLED PROGRAM (TAC NO. MF5096)

By letter dated October 22, 2014, Dominion Nuclear Connecticut, Inc. (DNC) submitted a license amendment request (LAR) for Millstone Power Station Unit 2 (MPS2). The proposed amendment would relocate certain technical specification (TS) surveillance frequencies to a licensee-controlled program by adopting Technical Specification Task Force (TSTF) -425, Revision 3, "Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed Technical Specification Task Force]

Initiative 5b." The proposed change would also add a new program, the Surveillance Frequency Control Program, in accordance with TSTF-425. In an email dated May 6, 2015, the Nuclear Regulatory Commission (NRC) transmitted a request for additional information (RAI) related to the LAR. DNC responded to the RAI in a letter dated June 5, 2015. In an email dated June 26, 2015, the NRC transmitted a second RAI. DNC agreed to respond to the RAI by July 27, 2015. provides DNC's response to the second RAI.

If you have any questions regarding this submittal, please contact Wanda Craft at (804) 273-4687.

Sincerely, Mark D. Sartain Vice President - Nuclear Engineering COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and State aforesaid, today by Mark D.

Sartain, who is Vice President - Nuclear Engineering of Dominion Nuclear Connecticut, Inc. He has affirmed before me that he is duly authorized to execute and file the foregoing document in behalf of that company, and that the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this

_0 +4_ day of

.,2015.

My Commission Expires:

"G"oAJA!A\\

I1 Z lo I to WANDA D. CRAFT Notary Publ, ~

I1 Notary Public Notary Publi' Commonwealth of Virginia MonReg. # 7520495

]My Commission Expires January 31,20L6_

Serial No.15-342 Docket No. 50-336 Page 2 of 2

Attachment:

1. Response to Second Request for Additional Information Regarding Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program
2.

Technical Specifications Marked-up Pages Commitments made in this letter: None cc:

U.S. Nuclear Regulatory Commission Region I 2100 Renaissance Blvd.

Suite 100 King of Prussia, PA 19406-2713 R. V. Guzman Senior Project Manager - Millstone Power Station U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08 C2 11555 Rockville Pike Rockville, MD 20852-2738 Director, Radiation Division Department of Energy and Environmental Protection 79 Elm Street Hartford, CT 06106-5127 NRC Senior Resident Inspector Millstone Power Station

Serial No.15-342 Docket No. 50-336 ATTACHMENT 1 RESPONSE TO SECOND REQUEST FOR ADDITIONAL INFORMATION REGARDING RELOCATION OF SPECIFIC SURVEILLANCE FREQUENCY REQUIREMENTS TO A LICENSEE CONTROLLED PROGRAM MILLSTONE POWER STATION UNIT 2 DOMINION NUCLEAR CONNECTICUT, INC.

Serial No.15-342 Docket No. 50-336 Attachment, Page 1 of 2 By letter dated October 22, 2014, Dominion Nuclear Connecticut, Inc. (DNC) submitted a license amendment request (LAR) for Millstone Power Station Unit 2 (MPS2).

The proposed amendment would relocate certain technical specification (TS) surveillance frequencies to.a licensee controlled program by adopting Technical Specification Task Force (TSTF) -425, Revision 3, "Relocate Surveillance Frequencies to Licensee Control RITSTF [Risk-Informed Technical Specification Task Force] Initiative 5b."

The proposed change would also add a new program, the Surveillance Frequency Control Program, in accordance with TSTF-425.

In an email dated May 6, 2015, the Nuclear Regulatory Commission (NRC) transmitted a request for additional information (RAI) related to the LAR. DNC responded to the RAI in a letter dated June 5, 2015. In an email dated June 26, 2015, the NRC transmitted a second RAI.

This attachment provides DNC's response to the second RAI.

RAI I Please explain or provide adequate justification for the addition of the word "required" to SRs in all instances including 4.1.3.3, 4.3.1.1.1, 4.3.2.1.1, 4.3.3.1.1, 4.3.3.5, and 4.3.3.8.

DNC Response DNC added the word "required" to Surveillance Requirements (SRs) 4.1.3.3, 4.3.1.1.1, 4.3.2.1.1, 4.3.3.1.1, 4.3.3.5, and 4.3.3.8 for clarification purposes only.

The limiting conditions for operation (LCOs) associated with each of these SRs specify a minimum number of channels required to be operable in applicable modes of operation. Under certain conditions or modes, the LCOs allow less than the total number of channels to be operable (e.g., 2 out of 4 channels). As currently written, these SRs may be misleading since they imply that all channels are required to be demonstrated operable. Although this clarification is outside the scope of TSTF-425, Revision 3, it is consistent with the license amendment request to adopt TSTF-425 for Millstone Unit 3 which was approved by the NRC under License Amendment 258 (ADAMS Accession No. ML14023A748).

RAI 2

On page 2 of 5 of Attachment I in the LAR, the licensee states that the word "PROGRAM" will be deleted from the table 4.7-2 title, but that word also appears in the SR 4.7.1.4 description on page 3/4 7-7. Please submit a TS markup to remove the corresponding word 'program" from the SR 4.7.1.4 description or alternatively provide an explanation of why the word should be retained.

DNC Response DNC agrees that the word "program" in Surveillance Requirement (SR) 4.7.1.4 should be deleted to be consistent with deletion of the word "PROGRAM" from the title descriptor in

Serial No.15-342 Docket No. 50-336 Attachment, Page 2 of 2

'Table 4.7.2.

The TS markup to reflect this change to SR 4.7.1.4 is provided in.

RAI 3

In SR 4.8.2. 1Ab, the licensee proposes to add "the frequency specified in the Surveillance Frequency Control Program (SFCP)," in place of the "least once per refueling" currently specified. However, this does not appear to be a routine periodic surveillance, in that this frequency appears to be a frequency that is "event-driven with a time component for performing the surveillance on a one-time basis once the event occurs." Please provide the technical basis for relocating this frequency to the SFCP.

Per Section 2.0 of the approved TSTF-425, Revision 3, relocation of "Frequencies that are event-driven but have a time component for performing the surveillance on a one time basis once the event occurs" are specifically prohibited.

DNC Response The frequency specified in SR 4.8.2.lAb of "at least once per refueling" is a routine periodic surveillance that is performed on an 18-month interval during each refueling outage. Due to the custom format and wording of the MPS2 TSs, the frequency can appear to be event-driven and therefore not a candidate for relocation to the SFCP.

However, in this case, the term "refueling" is used to define the interval or frequency.

The wording contained in SR 4.8.2.lAb is similar to the wording in SRs 4.4.3.1.2 and 4.4.3.2.2 for MPS3. These surveillances, which specified "at least once each refueling interval" were approved for relocation to the SFCP under MPS3 License Amendment 258 (ADAMS Accession No. ML14023A748).

RAI 4

On page 4 of 12 of Attachment 4 in the LAR, the licensee indicated that SR 4.1.1.5 would be included with the LAR.

The NRC staff has not found page 3/4 1-7 included with the original submittal. Does MPS2 intend to include the SR 4.1.1.5 frequency in the change?

DNC Response Yes. DNC proposes to include SR 4.1.1.5 (i.e., SR 4.1.1.5.b) in the change since it does not meet any of the four exclusion criteria specified in TSTF-425, Revision 3. The TS mark-up to reflect relocation of the surveillance frequency in SR 4.1.1.5.b to the SFCP, is provided in Attachment 2.

Serial No.15-342 Docket No. 50-336 ATTACHMENT 2 TECHNICAL SPECIFICATIONS MARKED-UP PAGES MILLSTONE POWER STATION UNIT 2 DOMINION NUCLEAR CONNECTICUT, INC.

Serial No.15-342 Docket No. 50-336, Page 1 of 2 Aug1iet 1,19:75 PLANT SYSTEMS ACTIVITY LIMITING CONDITION FOR OPERATION 3.7.1.4 The specific activity of the secondary coolant system shall be

  • 0.10 uCi/gram DOSE EQUIVALENT 1-13 1.

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

With the specific activity of the secondary coolant system > 0.10 uCi/gram DOSE EQUIVALENT 1-131, be in COLD SHUTDOWN within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> after detection.

SURVEILLANCE REQUIREMENTS 4.7.1.4 The specific activity of the secondary coolant system shall be determined to be within the limit by performance of the sampling and analysis pr-oegm of Table 4.7-2.

MILLSTONE - UNIT 2 3/4 7-7

Serial No.15-342 Docket No. 50-336, Page 2 of 2 REACTIVITY CONTROL SYSTEMS MINIMUM TEMPERATURE FOR CRITICALITY LIMITING CONDITION FOR OPERATION 3.1.1.5 The Reactor Coolant System temperature (Tavg) shall be Ž 515'F when the reactor is critical.

APPLICABILITY:

MODES 1 and 2*.

ACTION:

With the Reactor Coolant System temperature (Tavg) < 515'F, restore Tavg to within its limit within 15 minutes or be in HOT STANDBY within the next 15 minutes.

SURVEILLANCE REQUIREMENTS 4.1.1.5 The Reactor Coolant System temperature (Tavg) shall be determined to be Ž 515'E

a.

Within 15 minutes prior to making the reactor critical, and

b.

AfAlemt,nee per when the reactor is critical and the Reactor Coolant System emperature (Tavg) is < 525°F.

Z[the frequency specified in the Surveillance Frequency Control Program With Keff Ž- 1.0.

MILLSTONE - UNIT 2 3/4 1-7 AMENDMENT NO. -24, 480