ML15175A241

From kanterella
Jump to navigation Jump to search
Shine Medical Technologies V. 0 - Chapter 04 - Figures 4a2.1-001 Through 4a2.8-002
ML15175A241
Person / Time
Site: SHINE Medical Technologies
Issue date: 06/16/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.20, SHN.PSAR.P, SHN.PSAR.P.9
Download: ML15175A241 (14)


Text

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Summary Description Figure 4a2.1 Irradiation Unit Cell Schematic SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Summary Description Figure 4a2.1 Subcritical Assembly Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Subcritical Assembly Figure 4a2.2 Target Solution Process Hold Tank Elevations Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Subcritical Assembly Figure 4a2.2 TSV Interface during IU Operations 1TOGS01C 1TOGS01S TSV OFFGAS TSV OFFGAS BLOWERS ZEOLITE BEDS 1TOGS01F TSV OFFGAS DEMISTER 1TOGS02S RPCS TSV OFFGAS RETURN RECOMBINER BEDS 1TOGS01A RPCS RETURN TSV OFFGAS CONDENSER 1TOGS02A RPCS TSV OFFGAS SUPPLY RECOMBINER RPCS CONDENSER SUPPLY 1SCAS01S 1PCLS01D TSV PCLS COOLING WATER DEIONIZER UNIT RPCS RETURN 1PCLS01A PCLS COOLER RPCS SUPPLY 1PCLS01P PCLS COOLING WATER PUMP SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Neutron Driver Figure 4a2.3 Neutron Driver Assembly System Subsystems Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Neutron Driver Figure 4a2.3 Solid Model of 300 kV Direct Injection Accelerator Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

SHINE Medical Technologies Rev. 0

Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Neutron Driver Figure 4a2.3 Schematic of the Differential Pumping System as Built at PNL SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description TSV and Light Water Pool Figure 4a2.4 Irradiation Unit Decay Heat Curve Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Thermal Hydraulic Design Figure 4a2.7 PCLS Stream Table Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Thermal Hydraulic Design Figure 4a2.7 LWPS Stream Table Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

SHINE Medical Technologies Rev. 0

Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Thermal Hydraulic Design Figure 4a2.7 PCLS Process Flow Diagram

[Proprietary]

[Proprietary]

SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Thermal Hydraulic Design Figure 4a2.7 LWPS Process Flow Diagram MUPS SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Gas Management System Figure 4a2.8 TOGS Process Flow Diagram SHINE Medical Technologies Rev. 0

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Gas Management System Figure 4a2.8 TOGS Layout Sketch Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies Rev. 0