Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.4-001 Through 2.4-011
ML15161A156
Person / Time
Site: SHINE Medical Technologies
Issue date: 05/21/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.18, SHN.PSAR.P, SHN.PSAR.P.8
Download: ML15161A156 (11)


Text

Chapter 2 - Site Characteristics Hydrology Figure 2.4 SHINE Site in Relation to Rock River SHINE SITE ROCK RIVER SHINE SITE UN-NAMED TRIBUTARY 1 TO THE ROCK RIVER U.S. GEOLOGICAL SURVEY (USGS) 05430500 ROCK RIVER GAUGE AT AFTON, WI 1 0 1 SCALE MILES LEGEND REFERENCE

     

SHINE SITE SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Schematic of the Flow System in Rock County NOTE 1.) ARROWS INDICATE THE POTENTIAL FLOW DIRECTIONS REFERENCE 1.)    

SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 SHINE Site Groundwater Monitoring Wells NOTES 1.) BOREHOLE AND WELL LOCATION LOCATIONS AS SURVEYED BY AYERS ASSOCIATES ON NOVEMBER 11, 2011.

2.) PROPOSED DEVELOPMENT AREA IS A SQUARE, MEASURING 316 FEET ON EACH SIDE.

3.) CENTER OF BUILDING OUTLINE PLACED WITHIN PROPOSED SITE POLYGON AS DIRECTED BY CLIENT.

FAA ZONE C BOUNDARY REFERENCE 1.)

1.) AERIAL IMAGERY DISTRIBUTED BY CITY OF JANESVILLE AND PROVIDED BY CLIENT.

USDA, 2011.

PROPOSED 2.) ADDITIONAL AERIAL IMAGERY PROVIDED BY NAIP AND DISTRIBUTED BY U.S.G.S.

PROPERTY 3.) FAA ZONE C BOUNDARY OF THE SOUTHERN WISCONSIN REGIONAL REPORT LAND BOUNDARY USE PLAN AND AIRPORT OVERLAY ZONING DISTRICT ORDINANCE WAS PROVIDED BY CITY OF JANESVILLE ON 10/4/11.

SM-GW1A ORIGINAL PROPOSED LEGEND G11-02 G11-01 DEVELOPMENT G11-08 G11-03 AREA BOREHOLE LOCATION AND DESIGNATOR SM-GW4A VSP-01 G11-06 BOREHOLE LOCATION WITH 2 INCH PVC INSTALLED FOR G11-04 SEISMIC TESTING AND DESIGNATOR G11-07 SM-GW3A G11-05 SM-GW2A G11-10 WELL LOCATION AND DESIGNATOR G11-08 G11-09 VSP-01 400 0 400 SCALE FEET SM-GW2A SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Simplified Groundwater Table Contours Based on Measured Groundwater Elevations in Monitoring Wells Water Water Table Table Elevation Elevation ft-NAVD-88 ft-NAVD-88 (Feet) (Feet)

A (Feet) B (Feet)

NOTES 1.) PLOT A BASED ON MEASUREMENTS FROM 10/26/2011.

2.) PLOT B BASED ON MEASUREMENTS FROM 06/12/2012.

3.) MAPS ARE JUST FOR VISUALIZATION PURPOSES. MAPS HAVE BEEN GENERATED BY SURFER DEFAULT PARAMETERS OF KRIGING SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 SHINE Site Monitored Hydraulic Gradients 0.09%

766.10 0.08%

WaterTableElevation(ft.)(NAVD88) 765.60 0.07%

765.10 0.06%

764.60 Gradient 0.05%

764.10 0.04%

763.60 SMGW1A 0.03%

763.10 SMGW2A SMGW3A 0.02%

762.60 SMGW4A E_W_gradient 762.10 0.01%

NS_gradient 761.60 0.00%

10/01/11 11/02/11 12/04/11 01/05/12 02/06/12 03/09/12 04/10/12 05/12/12 06/13/12 07/15/12 08/16/12 09/17/12 SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Piezometric Water Table Surface from 1958 1.5 0 1.5 SCALE MILES LEGEND SHINE SITE REFERENCE 1.) LEROUX, 1963.

SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 SHINE Site Vicinity Hydraulic Features Wisconsin River Lake Butte des Morts Lake Winnebago Rynearson Flowage Lake Michigan Castle Rock Lake Rush Lake Sheboygan Lake Wisconsin River Green Lake Little Green Lake Wisconsin River Mason Lake Lake Emily Lake Redstone Fox Lake Mirror Lake Mud Lake Cedar Lake Lake Wisconsin Sinissippi Lake Pike Lake Crystal Lake Pine Lake Lake Mendota Lake Monona Rock Lake Pewaukee Lake LEGEND Lake Waubesa Rome Pond SHINE SITE Lake Kegonsa Monteray Muskego Lake DAM LOCATION AND Lake Koshkonong IDENTIFER Indian Ford Tichigan Lake Yellowstone Lake Whitewater Lake Upper Janesville LAKES (REGIONAL)

Eagle Lake JANESVILLE (RM 177)

SOUTHERN WISCONSIN REGIONAL Monteray AIRPORT / SITE (RM 172.5) Lake Como WATER (REGIONAL)

Lake Geneva AFTON USGS GUAGE (RM 172) Elizabeth Lake 100 MILE RADIUS Lake Marie Fox Lake STATE BOUNDARY Wonder LakeLong Lake 20 0 20 SCALE MILES Crystal Lake Lake Zurich REFERENCE 1.) LAKE (REGIONAL)

NATIONAL DATA ATLAS OF THE USDEVELOPED AND USGS, AND DISTRIBUTED BY ESRI 2004a; Spring Lake BASED ONATLAS NATIONAL THE U.S.

OF NATIONAL ATLAS THE US AND WATER USGS, 2004b;FEATURE AREAS AS WDNR, 2012a DEVELOPED BY NATIONAL ATLAS OF THE UNITED STATES AND THE UNITED STATES GEOLOGICAL SURVEY AS PUBLISHED ON 11/09/1999.

2.) WATER (REGIONAL) DATA DEVELOPED AND DISTRIBUTED BY ESRI BASED ON THE U.S. NATIONAL ATLAS WATER FEATURE LINES AS DEVELOPED BY NATIONAL ATLAS OF THE UNITED STATES AND THE UNITED STATES GEOLOGICAL SURVEY AS PUBLISHED ON 11/09/1999.

Lake Calumet 3.) RIVER MILES FOR ROCK RIVER AS PROVIDED BY WINNEBAGO Orland Lake COUNTY GEOGRAPHIC INFORMATION SYSTEM, ROCK RIVER WATER Lake Holiday TRAIL, BELOIT TO ROCKFORD SECTION G, AND DATED 8/28/12.

4.) DAM LOCATIONS FROM WISCONSIN OFFICE OF DAM SAFTEY, WISCONSIN DEPARTMENT OF NATURAL RESOURCES:

HTTP://DNR.WI.GOV/TOPIC/DAMS/

Mississippi River Cedar Lake Spring Lake NOTE 1.) RIVER MILES (RM) ARE BASED ON UPSTREAM DISTANCES ALONG Goose Lake ROCK RIVER FROM CONFLUENCE OF THE MISSISSIPPI RIVER.

SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Rock River Cross-Section Used in PMF Calculation 840 830 820 Elevation (ft NAVD-88) 810 800 790 780 770 760 750 0+00 50+00 100+00 150+00 200+00 Station REFERENCE 1.) USGS, 2012.

SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Dam Locations in Vicinity of SHINE Site SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Plan - PMP Zones for SHINE Site Area SHINE Medical Technologies Rev. 0

Chapter 2 - Site Characteristics Hydrology Figure 2.4 Plan - Off-Site Drainage Area Delineation SHINE Medical Technologies Rev. 0