jjk REG(

0 UNITED STATE.U.

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RESPONSE TO GENERIC LETTER 96-05, "PERIODIC VERIFICATION OF DESIGN-BASIS CAPABILITY OF SAFETY-RELATED MOTOR-OPERATED VALVES" DUKE ENERGY CORPORATION OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 DOCKET NUMBERS 50-269, 270, AND 287

1.0 INTRODUCTION

Many fluid systems at nuclear power plants depend on the successful operation of motor-operated valves (MOVs) in order to perform their safety functions. Several years ago, MOV operating experience, testing, and research programs sponsored by the nuclear industry and the Nuclear Regulatory Commission (NRC), revealed weaknesses in a wide range of activities (including design, qualification, testing, and maintenance) associated with the performance of MOVs in nuclear power plants. For example, some engineering analyses used in sizing and setting MOVs did not adequately predict the thrust and torque required to operate valves under their design-basis conditions. In addition, inservice tests of valve stroke time under zero differential-pressure and flow conditions did not ensure that MOVs could perform their safety functions under design-basis conditions.

Upon identification of the weaknesses in MOV performance, significant industry and regulatory activities were initiated to verify the design-basis capability of safety-related MOVs in nuclear power plants. After completion of these activities, nuclear power plant licensees began establishing long-term programs to maintain the design-basis capability of their safety-related MOVs. This safety evaluation (SE) addresses the program developed by Duke Energy Corporation (licensee) to periodically verify the design-basis capability of safety-related MOVs at the Oconee Nuclear Station, Units 1, 2, and 3.

2.0 REGULATORY REQUIREMENTS The NRC regulations require that MOVs important to safety be treated in a manner that provides assurance of their intended performance. Criterion 1 to Appendix A, "General Design Criteria for Nuclear Power Plants," to Part 50 of Title 10 of the Code of Federal Regulations (10 CFR Part 50) states, in part, that structures, systems, and components important to safety shall be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions to be performed. The quality assurance program to be applied to safety-related components is described in Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants," to 10 CFR Part 50. In Section 50.55a of 10 CFR Part 50, the NRC requires licensees to establish inservice testing (IST) programs in accordance with Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Chapter 3 of the Oconee Updated Final Safety Analysis Report contains similar criteria.

9908050165 990802 PDR ADOCK 05000269 P

PDR

-2 In response to concerns regarding MOV performance, the NRC staff issued Generic Letter (GL) 89-10 (June 28, 1989), "Safety-Related Motor-Operated Valve Testing and Surveillance,"

which requested that nuclear power plant licensees and construction permit holders ensure the capability of MOVs in safety-related systems to perform their intended functions by reviewing MOV design bases, verifying MOV switch settings initially and periodically, testing MOVs under design-basis conditions where practicable, improving evaluations of MOV failures and necessary corrective action, and trending MOV problems. The staff requested that licensees complete the GL 89-10 program within approximately three refueling outages or five years from the issuance of the GL.

The NRC staff issued seven supplements to GL 89-10 that provided additional guidance and information on MOV program scope, design-basis reviews, switch settings, testing, periodic.

verification, trending, and schedule extensions. GL 89-10 and its supplements provided only limited guidance regarding MOV periodic verification and the measures appropriate to assure preservation of design-basis capability. Consequently, the staff determined that additional guidance on the periodic verification of MOV design-basis capability should be provided.

On September 18, 1996, the NRC staff issued GL 96-05, "Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves." This GL requested that each licensee establish a program or ensure the effectiveness of its current program, and verify on a periodic basis that safety-related MOVs continue to be capable of performing their safety functions within the current licensing bases of the facility. In GL 96-05, the staff summarized several industry and regulatory activities and programs related to maintaining long-term capability of safety-related MOVs. For example, GL 96-05 discussed non-mandatory ASME Code Case OMN-1, "Alternative Rules for Preservice and Inservice Testing of Certain Electric Motor Operated Valve Assemblies in LWR Power Plants, OM Code 1995 Edition; Subsection ISTC."

This code case allows the replacement of ASME Code requirements for MOV quarterly stroke time testing with exercising of safety-related MOVs at least once per operating cycle and periodic MOV diagnostic testing on a frequency that is based on margin and degradation rate criteria. In GL 96-05, the staff stated that the method described in OMN-1 meets the intent of the generic letter with certain limitations and that licensees remain bound by the requirements in their code of record regarding MOV stroke-time testing, as supplemented by relief requests approved by the.staff.

In GL 96-05, licensees were requested to submit the following information:

a. within 60 days from the date of GL 96-05, a written response indicating whether or not the licensee would implement the requested actions; and
b. within 180 days from the date of GL 96-05, or upon notification to the NRC of completion of GL 89-10 (whichever is later), a written summary description of the licensee's MOV periodic verification program.

The staff is preparing an SE on the response of each licensee to GL 96-05. The staff intends to rely to a significant extent on an industry initiative to identify valve age-related degradation that could adversely affect the design-basis capability of safety-related MOVs (described in Section 3.0 below) where a licensee commits to implement that industry program. The staff will

-3 conduct inspections to verify the implementation of GL 96-05 programs at nuclear power plants as necessary.

3.0 JOINT OWNERS GROUP PROGRAM ON MOV PERIODIC VERIFICATION In response to GL 96-05, the Boiling Water Reactor Owners Group (BWROG), Westinghouse Owners Group (WOG), and Combustion Engineering Owners Group (CEOG) jointly developed an MOV periodic verification program to obtain benefits from the sharing of information between licensees. The Joint Owners Group (JOG) Program on MOV Periodic Verification is described by the BWROG in its Licensing Topical Report NEDC-32719, "BWR Owners' Group Program on Motor-Operated Valve (MOV) Periodic Verification," and described by WOG and CEOG in their separately-submitted Topical Report MPR-1807, "Joint BWR, Westinghouse and Combustion Engineering Owners' Group Program on Motor-Operated Valve (MOV) Periodic Verification." The stated objectives of the JOG Program on MOV Periodic Verification are (1) to provide an approach for licensees to use immediately in their GL 96-05 programs, (2) to develop a basis for addressing the potential age-related increase in required thrust or torque under dynamic conditions, and (3) to use the developed basis to confirm, or if necessary to modify, the applied approach. The specific elements of the JOG program are to (1) provide an "interim" MOV periodic verification program for applicable licensees to use in response to GL 96-05, (2) conduct a dynamic testing program over the next five years to identify potential age-related increases in required thrust or torque to operate gate, globe, and butterfly valves under dynamic conditions, and (3) evaluate the information from the dynamic testing program to confirm or modify the interim program assumptions.

The JOG interim MOV periodic verification program includes (1) continuation of MOV stroke-time testing required by the ASME Code IST program, and (2) performance of MOV static diagnostic testing on a frequency based on functional capability (age-related degradation margin that is over and above the margin for GL 89-10 evaluated parameters) and safety significance. In implementing the interim MOV static diagnostic test program, licensees will rank MOVs within the scope of the JOG program according to their safety significance. The JOG program specifies that licensees need to justify their approach for risk ranking MOVs. In Topical Report NEDC 32264, "Application of Probabilistic Safety Assessment to Generic Letter 89-10 Implementation," the BWROG described a methodology to rank MOVs in GL 89-10 programs with respect to their relative importance to core-damage frequency and other considerations to be added by an expert panel. In an SE dated February 27,1996, the NRC staff accepted the BWROG methodology for risk ranking MOVs in boiling water reactor nuclear plants with certain conditions and limitations. In the SE dated October 30, 1997, on the JOG Program on MOV Periodic Verification, the staff indicated its view that the BWROG methodology for MOV risk ranking is appropriate for use in response to GL96-05. With respect to Westinghouse-designed pressurized water reactor nuclear plants, the WOG prepared Engineering Report V-EC-1658, "Risk Ranking Approach for Motor-Operated Valves in Response to Generic Letter 96-05." On April 14, 1998, the staff issued an SE accepting with certain conditions and limitations the WOG approach for ranking MOVs based on their risk significance. Licensees not applicable to the BWROG or WOG methodologies need to justify their MOV risk ranking approach individually.

The objectives of the JOG dynamic test program are to determine degradation trends in dynamic thrust and torque, and to use dynamic test results to adjust the test frequency and method specified in the interim program if warranted. The JOG dynamic testing program

-4 includes (1) identification of conditions and features that could potentially lead to MOV degradation, (2) definition and assignment of valves for dynamic testing, (3) testing valves three times over a five-year interval with at least a one year interval between valve-specific tests according to a standard test specification, (4) evaluation of results of each test, and (5) evaluation of collective test results.

In the last phase of its program, the JOG will evaluate the test results to validate the assumptions in the interim program to establish a long-term MOV periodic verification program to be implemented by licensees. A feedback mechanism will be established to ensure timely sharing of MOV test results among licensees and to prompt individual licensees to adjust their own MOV periodic verification program, as appropriate.

Following consideration of staff comments, the BWROG submitted Licensing Topical Report NEDC-32719 (Revision 2) describing the JOG program on July 30, 1997. Similarly, the CEOG and the WOG submitted Topical Report MPR-1807 (Revision 2) describing the JOG program on August 6 and 12, 1997, respectively. On October 30, 1997, the staff issued an SE to the BWROG, CEOG and WOG accepting the JOG program with certain conditions and limitations as an acceptable industry-wide response to GL 96-05 for valve age-related degradation.

4.0 OCONEE GL 96-05 PROGRAM On November 14, 1996, Duke Energy Corporation submitted a 60-day response to GL 96-05 notifying the NRC that it would implement the requested MOV periodic verification program at Oconee Nuclear Station, Units 1, 2, and 3. On March 17, 1997, the licensee submitted the requested 180-day response to GL 96-05, which provided a summary description of the MOV periodic verification program planned to be implemented at Oconee. In a submittal dated March 31, 1998, the licensee updated its commitment to GL 96-05. On May 24, 1999, the licensee provided a response to a request for additional information regarding GL 96-05 that had been issued by the staff on February 16, 1999.

In its letter dated March 31, 1998, the licensee stated that, as a member of the WOG through its other pressurized water reactor plants, it committed to continue its participation in the JOG MOV Periodic Verification Program and to implement the program elements described in the Topical Report MPR-1807 (Revision 2) describing the JOG program. The licensee also addressed the specific conditions identified in the SE dated October 30, 1997, accepting the JOG program.

In its letter dated March 17, 1997, the licensee described its MOV periodic verification program, including the scope, existing and planned testing, and implementation of the JOG program at Oconee. For example, the licensee described the interim MOV static diagnostic test program at Oconee as applying the same MOV risk and margin threshold values as identified in the JOG topical report. The licensee also stated that dynamic testing of selected MOVs would be performed to support the JOG dynamic test program. The licensee stated that adjustments would be made to its GL 96-05 program based on the review of static and dynamic test results.

The licensee committed to transition to the JOG program in the first quarter of 1998. During a telephone conference with the staff on July 13, 1999, the licensee stated that it plans to incorporate the Topical Report to be developed by the Babcock & Wilcox Owners Group (B&WOG) into its GL 96-05 program if the B&WOG joins the JOG program.

-5 5.0 NRC STAFF EVALUATION The staff has reviewed the information provided in the licensee's submittals describing the program to verify periodically the design-basis capability of safety-related MOVs at Oconee in response to GL 96-05. NRC Inspection Report 50-269, 270, & 287/95-25 (IR 95-25) provided the results of an inspection to evaluate the licensee's program to verify the design-basis capability of safety-related MOVs in response to GL 89-10. The staff closed the review of the GL 89-10 program at Oconee in IR 95-25 based on verification of the design-basis capability of safety-related MOVs at Oconee and a documented plant process to confirm several program assumptions. NRC Inspection Report 50-269, 270, & 287/97-05 (IR 97-05) provided the results of an inspection to evaluate completion of those MOV program assumptions.

The staff's evaluation of the licensee's response to GL 96-05 is described below.

5.1 MOV Program Scope In GL 96-05, the staff indicated that all safety-related MOVs covered by the GL 89-10 program should be considered in the development of the MOV periodic verification program. The staff noted that the program should consider safety-related MOVs that are assumed to be capable of returning to their safety position when placed in a position that prevents their safety system (or train) from performing its safety function and the system (or train) is not declared inoperable when the MOVs are in their non-safety position. During the telephone conference on July 13, 1999, the licensee confirmed that MOVs that are required to return to their safety position in order for an operable system (or train) to perform its safety function were included in the scope of their GL 96-05 program.

In IR 95-25, the staff reviewed the scope of the licensee's MOV program in response to GL 89-10 at Oconee and found that the scope was consistent with GL 89-10 and its supplements. In its letter dated November 14, 1996, the licensee committed to implement the requested MOV periodic verification program at Oconee in response to GL 96-05 and did not take exception to the scope of the generic letter. Therefore, the staff considers the licensee to have made adequate commitments regarding the scope of its MOV program. The licensee will be responsible for justifying any deviations from the recommended scope of GL 96-05 at Oconee.

5.2 MOV Assumptions and Methodologies The staff expects licensees to maintain the assumptions and methodologies used in the development of its MOV programs for the life of the plant (a concept commonly described as a "living program"). For example, the design basis of safety-related MOVs will need to be maintained up to date, including consideration of any plant modifications or power uprate conditions.

In IR 95-25 and IR 97-05, the staff reviewed the licensee's justification for the assumptions and methodologies used in the MOV program in response to GL 89-10 at Oconee. With certain long-term aspects discussed in the following section, the staff determined that the licensee had adequately justified the assumptions and methodologies used in its MOV program. IR 97-05 and the licensee's letter dated May 24, 1999, described ongoing licensee activities, such as revising calculations and review of motor actuator output, to update MOV program assumptions

-6 and methodologies at Oconee. The staff considers the licensee to have adequate processes in place to maintain the assumptions and methodologies used in its MOV program, including the design basis of its safety-related MOVs.

5.3 GL 89-10 Long-Term Items When closing the NRC review of the GL 89-10 program at Oconee, the staff discussed in IR 95-25 several aspects of the licensee's MOV program to be addressed over the long term.

In IR 97-05, the staff determined that the licensee has adequately addressed the items identified during the previous inspection by completing the modifications specified for 11 MOVs.

In its letter dated May 24, 1999, the licensee reported on the status of the remaining long-term GL 89-10 items. For example, the licensee (1) completed reviews of the staff's SE of the Electric Power Research Institute (EPRI) MOV Performance Prediction Methodology (PPM) for applicability to Oconee's MOV program, (2) used an in-plant dynamic test to validate use of the EPRI MOV PPM for Crane gate valves with non-stellite seating surfaces, (3) replaced butterfly valve 1 CC-7, and (4) completed a prototype test of a 4-inch Velan gate valve that was used to justify the current valve factor assumed for feedwater valve 2FDW-104.

The staff completed the review of the licensee's actions in response to GL 95-07, "Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves," in an SE dated November 6, 1998.

In IR 95-25, the staff discussed quantitative and qualitative aspects of the licensee's program for trending MOV performance at Oconee. that included use of a trend database to evaluate test data and periodic reviews of MOV failures. For example, equipment failures and repeat work orders are reviewed on a quarterly basis. In its letter dated May 24, 1999, the licensee indicated that trending methods included evaluation of as-found and as-left diagnostic test data.

In IR 95-25, the staff concluded that the licensee had demonstrated the design-basis capability of its safety-related MOVs at Oconee. With the licensee's ongoing MOV activities and trending program, no outstanding issues regarding the licensee's GL 89-10 program remain at Oconee.

5.4 JOG Program on MOV Periodic Verification In its letter dated March 31, 1998, the licensee updated its commitment to implement the JOG Program on MOV Periodic Verification as described in Topical Report MPR-1807 (Revision 2) and responded to the conditions and limitations on use of the topical report identified in the NRC SE dated October 30, 1997. The JOG program includes (1) the JOG interim static diagnostic test program, (2) the JOG five-year dynamic test program, and (3) the JOG long-term periodic test program. The staff considers the commitments by the licensee to implement the JOG program at Oconee to be an acceptable response to GL 96-05 for valve age-related degradation. The staff considers that the licensee's commitment includes all three phases of the JOG program. If the licensee proposes to implement an approach at Oconee that is different from the JOG program, the licensee is expected to notify the NRC and provide justification for the proposed alternative approach.

In its letter dated March 17, 1997, the licensee stated that the interim MOV static diagnostic test program would establish a test frequency based on the safety significance and functional capability of each GL 96-05 MOV. In its letter dated May 24, 1999, the licensee indicated that

-7 MOV ranking at Oconee was assigned based on the MOV risk ranking approach and results presented in the WOG Engineering Report V-EC-1 658-A (Revision 2). A sample list of high-risk MOVs from two other B&W facilities was compiled and will be used for comparison.

An expert panel will also compare Oconee's MOVs to the sample list included in the WOG engineering report. The licensee stated that it will comply with the conditions and limitations in the SE dated April 14, 1998, which accepted WOG Engineering Report V-EC-1 658 in implementing the WOG MOV risk ranking methodology. During the telephone conference on July 13, 1999, the licensee stated that it would apply the B&WOG MOV risk ranking approach when it becomes available.

In its letter dated May 24, 1999, the licensee stated that diagnostic methods that acquire data from the motor control center (MCC) are used for periodic verification testing on certain high margin butterfly valves where static loads are representative of design basis loads. In these cases, a qualitative review of the MCC data includes a comparison to baseline data. The licensee indicated that in the future, MCC data may be used for periodic verification tests on high-margin rising-stem MOVs. In applying test data obtained from the MCC in its GL 96-05 program, the licensee will be expected to address the following issues as applicable to its use of MCC test data: (1) the correlation between new MCC test data and existing direct MOV data measurements; (2) the relationship between changes in MCC test data and MOV thrust and torque performance; (3) system accuracies and sensitivities to MOV degradation for both outputs and operating performance requirements; and (4) validation of MOV operability using MCC testing. Based on the licensee's summary, the staff considers the licensee's methodology for using MCC testing to monitor valve degradation to be reasonable.

The JOG program is intended to address most gate, globe, and butterfly valves used in safety-related applications in the nuclear power plants of participating licensees. The JOG indicates that each licensee is responsible for addressing any MOVs outside the scope of applicability of the JOG program. In the SE dated October 30, 1997, the staff specified that licensees implementing the JOG program must determine if any MOVs are outside the scope of the JOG program (including service conditions) and justify a separate program for periodic verification of the design-basis capability of those MOVs. In its letter dated March 31, 1998, the licensee stated that it had reviewed its GL 96-05 population and had identified only Kerotest globe valves as being outside the scope of JOG applicability. The licensee stated that age related degradation will be addressed separately for these valves. The staff recognizes that the JOG has selected a broad range of MOVs and conditions for the dynamic testing program.

Consequently, the staff expects significant information to be obtained on the performance and potential degradation of safety-related MOVs during the interim static diagnostic test program and the JOG dynamic test program. As the test results are evaluated, the JOG might include or exclude additional MOVs with respect to the scope of its program. Although the test information from the MOVs in the JOG dynamic test program might not be adequate to establish a long-term periodic verification program for each MOV outside the scope of the JOG program, sufficient information should be obtained from the JOG dynamic test program to identify any immediate safety concern for potential age-related degradation of valves during the interim period of the JOG program. Therefore, the staff considers it acceptable for the licensee to apply its interim static diagnostic test program to GL 96-05 MOVs that currently might be outside the scope of the JOG program with the feedback of information from the JOG dynamic test program to those MOVs. Upon completion of the JOG dynamic test program and development of the JOG long-term MOV periodic verification criteria, the licensee is expected to establish a long-term MOV periodic verification program for those MOVs outside the scope of

-8 the JOG program by applying information from the JOG program or additional dynamic tests, as necessary.

5.5 Motor Actuator Output The JOG program focuses on the potential age-related increase in the thrust or torque required to operate valves under their design-basis conditions. In the SE dated October 30, 1997, on the JOG program, the staff specified that licensees are responsible for addressing the thrust or torque delivered by the MOV motor actuator and its potential degradation. Although the JOG does not plan to evaluate degradation of motor actuator output, significant information on the output of motor actuators will be obtained through the interim MOV static diagnostic test program and the JOG dynamic test program.

In its letter dated May 24, 1999, the licensee indicated that it uses a combination of preventive maintenance activities, periodic as-found and as-left static diagnostic testing, periodic dynamic diagnostic testing as prescribed by the JOG program, trending of MOV performance and failures,.and bench testing of actuators to assure that adequate actuator output capability exists for safety-related MOVs at Oconee to perform their design-basis functions. The licensee also intends to incorporate information obtained from industry initiatives into the Oconee MOV program. The staff notes that several parameters can be obtained during MOV static and dynamic testing to help identify motor actuator output degradation when opening and closing the valve including, as applicable, capability margin, thrust and torque at control switch trip, stem friction coefficient, load sensitive behavior, and motor current.

In Technical Update 98-01 and its Supplement 1, the Limitorque Corporation provided updated guidance for predicting the torque output of its motor actuators. In its letter dated May 24, 1999, the licensee reported that it had implemented the guidance contained in Technical Update 98-01 and its Supplement 1 into the Oconee MOV program. The licensee used the Commonwealth Edison Company (ComEd) ac motor test program and its own actuator test data to resolve specific equipment concerns. The licensee did not identify any deficiencies affecting MOV operability in its May 24, 1999, letter. The staff notes that the licensee is responsible for (1) resolving any MOV operability concerns in accordance with regulatory and plant-specific requirements, and (2) addressing any changes to the ComEd ac-powered MOV output guidance resulting from Limitorque Technical Update 98-01.

In its letter dated July 17, 1998, forwarding Technical Update 98-01, Limitorque also indicated that a future technical update will be issued to address the application of dc-powered MOVs. In its letter dated May 24, 1999, the licensee stated that there are nine dc-powered MOVs in its GL 96-05 program and that it is using current Limitorque guidance that assumes pullout gearbox efficiency in predicting dc-powered MOV output. Further, the licensee stated that all nine dc-powered MOVs are normally operated under approximate design-basis differential pressure and flow conditions. The licensee is monitoring the industry effort on dc-powered MOV performance to determine if any additional necessary action is necessary.

As a result, the staff considers the licensee to be establishing sufficient means to monitor MOV motor actuator output and its potential degradation.

-9

6.0 CONCLUSION

On the basis of this evaluation, the staff finds that the licensee has established an acceptable program to verify periodically the design-basis capability of the safety-related MOVs at the Oconee Nuclear Station, Units 1, 2, and 3. Therefore, the staff concludes that the licensee has adequately addressed the actions requested in GL 96-05. The staff may conduct inspections to verify that implementation of the MOV periodic verification program is in accordance with the licensee's commitments, this NRC SE, the NRC SE dated October 30, 1997 (on the JOG Program on MOV Periodic Verification), and the NRC SE dated April 14, 1998 (on the WOG methodology for ranking MOVs by their safety significance as applied by the licensee for this B&W-design plant).

Principal Contributors: T. Scarbrough S. Tingen Date:

August 2, 1999