6.5 STATION OPERATING RECORDS Specification, 6.5.1 The following records shall be prepared and permanently retained in a manner convenient for review:
- a. Records of modifications to the station as described in the FSAR.
- b. Special nuclear material physical inventory records.
- c. Special nuclear material isotopic inventory records.
- d. Radiation monitoring records, including records of radiation and contamination surveys.
- e. Records of off-site environmental surveys.
- f. Personnel radiation exposure records as required by 10CFR20.
- g. Records of radioactive releases and waste disposal.
- h. Records of reactor coolant syster in-service inspections.
- i. Preoperational testing records.
- j.
Records of special reactor tests or experiments.
- k. Records of changes to safety-related operating procedures.
- 1. Records for Environmental Qualification which are covered under the provisions of paragraph 6.7..
6.5.2 The following records shall be prepared and retained for a minimum of six (6) years in a manner convenient for review:
- a. Switchboard Record.
- b. Reactor Operations Logbook.
- c. Shift Supervisor Logbook.
- d. Maintenance histories for station safety-related structures, systems and components.
- e. Records of safety-related inspections, other than reactor coolant system in-service inspections.
- f.
Recdrds of reportable occurrences.
- g.
Pe'riodic tctinl,, rt-cords and rt'cords of other periodic checks, calibrations, etc. performed in accordance with surveillance requirement; for safety-related miramcters, structures, systems and components.
Order dtd. Oct. 24, 1980 6.5-1 8Ollio al
ie 6.7 ENVIRONMENTAL QUALIFICATION 6.7.1 By no later than June 30, 1982 all safety-related electrical equipment in the facility shall be qualified in accordance with the provisions of Division of Operating Reactors "Guidelines for Evaluating Environmental Qualification of Class IE Electrical Equipment in Operating Reactors"(DOR Guidelines); or, NUREG-0588 "Interim Staff Position on Environmental Qualification of Safety-Related Electrical Equipment",
December 1979. Copies of these documents are attached to Order for Modi fication of Licenses DPR-38, DPR-47 and DPR-55 dated October 24, 1980.
6.7.2 By no later than December 1, 1980, complete and auditible records must be available and maintained at a central location which describe the environmental qualification method used for all safety-related electrical equipment in sufficient detail to document the degree of compliance with the DOR Guidelines or NUREG-0588.
Thereafter, such records should be updated and maintained current as equipment is replaced, further tested, or otherwise further qualified.
6.7-Order dated October 24, 1980