{{#Wiki_filter:FUGRO CONSULTANTS, INC. PR No.: PGEQ-PR-16

  • U COVER SHEET Revision:

1 Foundation Velocity Report Page 1 of33 PROJECT REPORT PGEQ-PR-16 TITLE: CCCSIP DCPP p. and S-Wave Foundation Velocity Report PROJECT NAME: PG&E CCCSIP 04.79225400 (FCL) PROJECT NO. PPD NO: 2234-PPD-001 ON: dc=com, dc=fugro ,I=Amer lca, Prepared By: , "'-()(\ ...-\... ou=WLAI, ou=People WLAI. y-Date: 2014.06.24 09:33:19 -06'00' Dr. Daniel O'Connell, Sr. Principal Geophysicist CheckedBy: Geophysicist Approved By: William Godwin, CEG, Principal Geologist Date: 6/24/2014 Date: (;/.;,f/il<>/ 1 Date: 6/24/2014

FUGRO CONSULTANTS, INC. PR No.: PGEQ-PR-16 VERIFICATION

SUMMARY

SHEET Revision: 1 I Foundation Velocity Report Page 3 of33 Item Parameter Yes No N/A 1 Purpose is clearly stated and Report satisfies the Purpose. v 2 Methodology is appropriate and properly applied. v' 3 Assumptions are reasonable, adequately described, and based v upon sound geotechnical principles and practices. 4 Input was authorized and correctly incorporated into the Report. v 5 Software is properly identified and applied; and validation is ,/ referenced, or included, and acceptable. 6 Detailed Discussion is complete, accurate, and leads logical to v Results and Conclusions. 7 Results and Conclusions are accurate, acceptable, and v' reasonable compared to the Input and Assumptions. If commercial software, such as EXCEL, MATLAB, IDL, or 8 Mathcad, was used, equations and other entries have been v checked as necessary to ensure correct results. 9 References are valid for intended use. v 10 Appendices are complete, accurate, and support text. ,/ Comments: (use additional pages as necessary)