Annual Radioactive Effluent Release Report
ML14197A112
Person / Time
Site: Calvert Cliffs  
Issue date: 07/11/2014
From: Flaherty M
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
Download: ML14197A112 (25)


Text

AE-Exelon Generation.

Mark D. Flaherty Plant Manager Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657 410 495 5205 Office 410 495 5444 Fax 443 534 5476 Mobile www.exeloncorp.com mnark.flaherty@exelon.com July 11, 2014 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555 Calvert Cliffs Nuclear Power Plant Unit Nos. 1 & 2; Docket Nos. 50-317 & 50-318 Facility Operating License Nos. DPR-53 and DPR-69 Independent Spent Fuel Storage Installation, Docket No. 72-8

Subject:

Annual Radioactive Effluent Release Report (a) Calvert Cliffs Unit Nos. 1 and 2 Technical Specification 5.6.3 (b) Calvert Cliffs ISFSI Technical Specification 6.3

References:

As required by References (a) and (b), Enclosure (1) is provided. Meteorological data is kept in an onsite file and is available upon request.

This letter contains no regulatory commitments.

Should you have questions regarding this matter, please contact Mr. Douglas E. Lauver at (410) 495-5219.

Respectfully, Mark D. Flaherty Plant Manager MDF/PSF/bjd

Enclosure:

Annual Radioactive Effluent Release Report for Calvert Cliffs Nuclear Power Plant and Independent Spent Fuel Storage Installation -2013 cc:

W. M. Dean, NRC NRC Project Manager, Calvert Cliffs NRC Resident Inspector, Calvert Cliffs C. Haney, NRC S. Gray, DNR J. Folkwein, ANI tjC-SSA

)aLL

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE ANNUAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 This report covers the period January 1, 2013 to December 31, 2013 for Calvert Cliffs Nuclear Power Plant.

This report covers the period June 1, 2013 to May 31, 2014 for the Independent Spent Fuel Storage Installation.

Calvert Cliffs Nuclear Power Plant July 11, 2014

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 Facility - Calvert Cliffs Nuclear Power Plant and Independent Spent Fuel Storage Installation Licensee - Calvert Cliffs Nuclear Power Plant, LLC This report covers the period January 1, 2013 to December 31, 2013 for Calvert Cliffs Nuclear Power Plant.

This report covers the period June 1, 2013 to May 31, 2014 for the Independent Spent Fuel Storage Installation.

REGULATORY LIMITS A.

Fission and Activation Gases

1.

The instantaneous release rate of noble gases in gaseous effluents shall not result in a site boundary dose rate greater than 500 mrem/year to the whole body or greater than 3000 mrem/year to the skin (Offsite Dose Calculation Manual (ODCM) Rev. 0802, 3.11.2.1).

2.

Gaseous Radwaste Treatment System and the Ventilation Exhaust Treatment System shall be used to reduce gaseous emissions when the calculated gamma-air dose due to gaseous effluents exceeds 1.20 mRad or the calculated beta-air dose due to gaseous effluents exceeds 2.4 mRad at the site boundary in a 92 day period (ODCM 3.11.2.4).

3.

The air dose at the site boundary due to noble gases released in gaseous effluents shall not exceed (ODCM 3.11.2.2):

10 mRad/qtr, gamma-air 20 mRad/qtr, beta-air 20 mRad/year, gamma-air 40 mRad/year, beta-air

4.

All of the above parameters are calculated according to the methodology specified in the ODCM.

B.

lodines and Particulates with Half Lives Greater than Eight Days

1.

The instantaneous release rate of iodines and particulates in gaseous effluents shall not result in a site boundary dose-rate in excess of 1500 mrem/year to any organ (ODCM 3.11.2.1).

2.

The Gaseous Radwaste Treatment System and the Ventilation Exhaust Treatment System shall be used to reduce radioactive materials in gaseous effluents when calculated doses exceed 1.8 mrem to any organ in a 92 day period at or beyond the site boundary (ODCM 3.11.2.4).

3.

The dose to a member of the public at or beyond the site boundary from iodine-131 and particulates with half-lives greater than eight days in gaseous effluents shall not exceed (ODCM 3.11.2.3):

15 mrem/qtr, any organ 30 mrem/year, any organ 1

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 less than 0.1% of the above limits as a result of burning contaminated oil.

4.

All of the above parameters are calculated according to the methodology specified in the ODCM.

C.

Liquid Effluents

1.

The concentrations of radionuclides in liquid effluents from the plant shall not exceed the values specified in 10 CFR Part 20, Appendix B, Table II, Column 2 for unrestricted areas (ODCM 3.11.1.1).

2.

The liquid radwaste treatment system shall be used to reduce the concentration of radionuclides in liquid effluents from the plant when the calculated dose to unrestricted areas exceeds 0.36 mrem to the whole body, or 1.20 mrem to any organ in a 92 day period (ODCM 3.11.1.3).

3.

The dose to a member of the public in unrestricted areas shall not exceed (ODCM 3.11.1.2):

3 mrem/qtr, total body 10 mrem/qtr, any organ 6 mrem/year, total body 20 mrem/year, any organ

4.

All liquid dose parameters are calculated according to the methodology specified in the ODCM.

I1.

MAXIMUM PERMISSIBLE CONCENTRATIONS A.

Fission and Activation Gases Prior to the batch release of gaseous effluents, a sample of the source is collected and analyzed by gamma spectroscopy for the principal gamma emitting radionuclides.

The identified radionuclide concentrations are evaluated and an acceptable release rate is determined to ensure that the dose rate limits of ODCM 3.11.2.1 are not exceeded.

B.

lodines and Particulates with Half Lives Greater than Eight Days Compliance with the dose rate limitations for iodines and particulates is demonstrated by analysis of the charcoal and particulate samples of the station main vents.

The charcoal samples are analyzed by gamma spectroscopy for quantification of radioiodine.

The particulate samples are analyzed by gamma spectroscopy for quantification of particulate radioactive material. All of the above parameters are calculated according to the methodology specified in the ODCM.

C.

Liquid Effluents The Maximum Permissible Concentrations (MPCs) used for radioactive materials released in liquid effluents are in accordance with ODCM 3.11.1.1 and the values from 10 CFR Part 20, Appendix B, Table II, Column 2 including applicable table 2

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 notes. In all cases, the more restrictive (lower) MPC found for each radionuclide is used regardless of solubility.

Ill.

TECHNICAL SPECIFICATION REPORTING REQUIREMENTS A.

Calvert Cliffs Nuclear Power Plant (CCNPP), Technical Specification 5.6.3

1.

2013 Offsite Dose Due to Carbon-14 Carbon-14 releases from Calvert Cliffs were estimated using the EPRI Carbon-14 Source Term Calculator using specific reactor core data and reactor coolant chemistry to estimate the products of the activation reactions.

The resulting estimate of Carbon-14 released from the Calvert Cliffs Site is 14.70 Curies.

Dose due to Carbon-14 in gaseous effluents was calculated using the following conditions:

a.

C-14 released to the atmosphere: 7.87 Curies of C-14 from Unit 1, 6.83 curies from Unit 2.

b.

Release was consistent throughout the year.

c.

10% of the C-14 was in the chemical form of C02, which is the only dose contributor. The bulk of C-14 was in the chemical form of methane (CH4) which would exhibit high upward velocity due to its low density relative to air. In addition, CH4 does not have an uptake pathway for humans.

d.

Meteorological dispersion factor (X/Q) at the site boundary to the hypothetical maximally exposed member of the public is 1.87E-0&7 sec/m 3.

e.

Dose calculations and dose factors are from Regulatory Guide 1.109 methodology.

f.

Pathways considered were inhalation and vegetation ingestion.

g.

Critical receptor is child at the site boundary in the SE direction.

Maximum dose values due to C-14 in gaseous effluents in 2013 Organ Age Pathway mremlyr 2

3 rd 4 th Quarter Quarter Quarter Quarter Bone Child Inhalation 3.13E-03 7.83E-4 7.83E-4 7.83E-4 7.83E-4 T. Body/Other Child Inhalation 5.86E-04 1.47E-4 1.47E-4 1.47E-4 1.47E-4 7.63E-7.63E-7.63E-7.63E-Bone Child Vegetation 3.05E-01 02 02 02 02 02 02 02 02 1,53E-1.53E-1.53E-1.53E-T. Body/Other Child Vegetation 6.11 E-02 02 02 02 02 02 02 02 02 3

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013

2.

2013 Dose Assessment Summary Actual Percent of ODCM Value ODCM limit Limit Liquid Waste:

Maximum Annual Organ Dose (mrem) 0.001 0.01%

20 Maximum Annual Whole Body Dose (mrem) 0.001 0.02%

6 Gaseous Waste:

Noble Gases:

Maximum Quarterly Gamma Air Dose (mRad) 0.0008 0.01%

10 Maximum Quarterly Beta Air Dose (mRad 0.006 0.03%

20 lodines and Particulates:

Maximum Annual Organ Dose (mrem) 2 0.02 0.07%

30 The controlling pathway was the fish and shellfish pathway with adult as the controlling age group and the liver representing the organ with the highest calculated dose during the calendar year of 2013.

2 The controlling pathway was the infant-thyroid pathway representing the organ with the highest calculated dose during the calendar year of 2013. There is currently no milk pathway.

3.

40 CFR 190 Total Dose Compliance Based upon the calendar year 2013 and the ODCM calculations, the maximum exposed individual would receive 0.02% of the allowable dose.

During the calendar year 2013, there were no on-site sources of direct radiation that would have contributed to a significant or measurable off-site dose. The direct radiation contribution is measured by both on-site and off-site thermoluminescent dosimeters (TLDs).

The results of these measurements did not indicate any statistical increase in the off-site radiation doses attributable to on-site sources. Therefore, no increase in the calculated offsite dose is attributed to the direct exposure from on-site sources. A more detailed evaluation may be found in the Annual Radiological Environmental Operating Report.

4.

Solid Waste Report Requirements During 2013, the types of radioactive solid waste shipped from Calvert Cliffs were dry compressible waste, spent resins, and cartridge filters which were shipped in either High Integrity Containers (HICs) within NRC approved casks, Sea/Land containers, or steel boxes.

Appendix A provides a detailed breakdown of the waste shipments for 2013 per Technical Specification 5.6.3.

At CCNPP, methods of waste and materials segregation are used to reduce the volume of solid waste shipped offsite for processing, volume reduction, and burial.

4

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013

5.

Offsite Dose Calculation Manual (ODCM) and Process Control Program (PCP) Changes The ODCM and PCP were not revised in 2013.

B.

Radioactive Effluent Monitoring Instrumentation

1.

The Unit 2 Steam Generator Blowdown Radiation Monitor 2-RE-4014 was inoperable during much of the calendar year 2013 due to component malfunction. The components were repaired and the Radiation Monitor was returned to service in 2014.

During the period the Radiation Monitor was inoperable, compensatory actions were performed in accordance with the ODCM requirements.

2.

The Waste Gas Decay Tank Discharge Monitor 0-RE-2191 was declared inoperable for greater than 30 days as the criteria and methodology for testing the monitor did not meet the ODCM requirements.

During the period the Radiation Monitor was inoperable, compensatory actions were performed in accordance with the ODCM requirements.

C.

Independent Spent Fuel Storage Installation (ISFSI), ISFSI Technical Specification 6.3 Zero (0) casks of spent fuel were transferred to the ISFSI during the reporting period.

No quantity of radionuclides was released to the environment during the ISFSI operation in 2013.

Additional information regarding the ISFSI radiological environmental monitoring program is included in the Annual Radiological Environmental Operation Report.

IV.

AVERAGE ENERGY Not Applicable.

V.

MEASUREMENTS AND APPROXIMATIONS AND TOTAL RADIOACTIVITY A.

Fission and Activation Gases

1.

Batch Releases Prior to each batch release of gas from a pressurized waste gas decay tank or containment, a sample is collected and analyzed by gamma spectroscopy using a germanium detector for the principal gamma emitting noble gas radionuclides. The total activity released is based on the pressure/volume relationship (gas laws).

The Plant Vent Stack Radiation Monitor typically monitors containment releases, and the values from the radiation monitor may be used to assist in the calculation of activity discharged from containment during venting. Carbon-14 is estimated per section III.A.I.

5

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013

2.

Continuous Releases A gas sample is collected at least weekly from the main vents and analyzed by gamma spectroscopy using a germanium detector for the principal gamma emitting noble gas radionuclides. The total activity released for the week is based on the total sample activity decay corrected to the sample time multiplied by the main vent flow for the week. The Plant Vent Stack Radiation Monitor continuously measures routine plant vent stack releases, per design, and the values from the radiation monitor may be used to assist in the calculation of activity discharged in routine plant vent stack discharges.

During each containment purge, a gas sample is collected and analyzed by gamma spectroscopy using a germanium detector to determine the concentration of principal gamma emitting noble gas radionuclides inside containment. Total activity released during a containment purge is based on continuous radiation monitor responses, grab samples, and purge fan flow rate.

A monthly composite sample is collected from the main vents and analyzed by liquid scintillation for tritium. The total tritium release for the month is based on the sample analysis and the main vent flow.

Carbon-14 is estimated per section III.A.1.

B.

Iodine and Particulates

1.

Batch Releases The total activities of radioiodines and particulates released from pressurized waste gas decay tanks, containment purges, and containment vents are accounted for by the continuous release methodology discussed in section V.B.2.

2.

Continuous Releases During the release of gas from the main vents, samples of iodines and particulates are collected using a charcoal and particulate filter, respectively.

The filters are removed weekly (or more often) and are analyzed by gamma spectroscopy using a germanium detector for significant gamma emitting radionuclides. The total activity released for the week is based on the total sample activity decay corrected to the midpoint of the sample period multiplied by the main vent flow for the week. A plate-out correction factor is applied to the results to account for the amount of iodine lost in the sample lines prior to sample collection. The weekly particulate filters are then combined to form monthly and quarterly composites for the gross alpha, strontium-89, and strontium-90 analyses. Iron-55 is analyzed twice per year.

6

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 C.

Liquid Effluents

1.

Batch Releases Prior to the release of liquid from a waste tank, a sample is collected and analyzed by gamma spectroscopy for the principal gamma emitting radionuclides.

To demonstrate compliance with the concentration requirements addressed in Section I.C.1 above, the measured radionuclide concentrations are compared with the allowable MPCs; dilution in the discharge conduit is considered, and an allowable release rate is verified.

The total activity released in each batch is determined by multiplying the volume released by the concentration of each radionuclide.

The actual volume released is based on the difference in tank levels prior to and after the release.

A proportional composite sample is also withdrawn from each release, and this is used to prepare monthly tritium and gross alpha, iron-55, nickel-63, strontium-89, and strontium-90 samples for analysis are prepared quarterly for offsite analysis.

Batch discharges of secondary (normally uncontaminated) waste streams are also monitored for radioactivity.

No activity is normally detected in these secondary waste streams (excluding tritium).

There were no major changes to the liquid radwaste system in calendar year 2013.

2.

Continuous Releases To account for activity from continuous releases, a sampte is collected and analyzed by gamma spectroscopy for the principal gamma emitting radionuclides. The measured radionuclide concentrations are compared with the allowable MPC concentrations in the discharge conduit, and an allowable release rate is verified.

When steam generator blowdown is discharged to the circulating water conduits, it is sampled and gamma isotopic analysis is performed at a minimum once per week. These results are multiplied by the actual quantity of blowdown to determine the total activity released. The weekly sample is also used to prepare monthly composites for tritium analysis.

During the monitoring for primary-to-secondary leakage low levels of tritium have been detected in the Turbine Building sumps. This water is sampled and analyzed for principal gamma emitting radionuclides weekly and composited.

The composite sample is analyzed at least monthly for tritium. The results are multiplied by the actual quantity of liquid released to determine the total activity released.

7

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 D.

Estimation of Total Error Total error for all releases was estimated using, as a minimum, the random counting error associated with typical releases. In addition to this random error, the following systematic errors were also examined:

1.

Liquid

a.

Error in volume of liquid released prior to dilution during batch releases.

b.

Error in volume of liquid released via steam generator blowdown.

c.

Error in amount of dilution water used during the reporting period.

2.

Gases

a.

Error in main vent release flow.

b.

Error in sample flow rate.

c.

Error in containment purge release flow.

d.

Error in gas decay tank pressure.

Where errors could be estimated they are usually considered additive.

E.

Reporting and Recordkeepinq for Decommissioning In accordance with 10 CFR 50.75.g, each licensee shall keep records of information important to the safe and effective decommissioning of the facility in an identified location until the license is terminated by the Commission. If records of relevant information are kept for other purposes, reference to these records and their locations may be used. Information the Commission considers important to decommissioning consists of records of spills or other unusual occurrences involving the spread of contamination in and around the facility, equipment, or site.

These records may be limited to instances when significant contamination remains after any cleanup procedures or when there is reasonable likelihood that contaminants may have spread to inaccessible areas as in the case of possible seepage into porous materials such as concrete. These records must include any known information on identification of involved nuclides, quantities, forms, and concentrations.

To assist in the decommissioning, and to provide early and advance detection of any unmonitored releases of radioactive material from the site, groundwater is routinely sampled. These groundwater samples are analyzed for gamma and tritium activity (see Tables below). Sample size and/or count times are adjusted to achieve analytical sensitivities better than the environmental LLDs for gamma emitters (listed in ODCM Table 4.12-1). Established LLD limits for tritium are approximately 350 pCi/I for tritium.

Groundwater samples were collected from nine on-site piezometer tubes throughout 2013.

A piezometer tube is a shallow monitoring well which allows access to groundwater at a depth of approximately 40 feet beneath the site. Eight additional wells were installed in 2013 and were included in fourth quarter monitoring. Of the piezometer tubes sampled, only #11 Piezometer Tube showed any plant related activity. This activity was previously identified and evaluated in December of 2005.

8

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 The activity consists of tritium originating from normal radwaste discharges and was previously reported in the Annual Radioactive Effluent Release Reports. The tritium contamination is contained on site.

No drinking water has been affected; the groundwater at this location does not impact any drinking water pathway.

The 2013 analysis result for tritium and gamma are shown in the following tables.

9

ENCLOSURE (I)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 Concentration of Tritium in Groundwater (Results in units of pCi/L +/- 2a)

Sample Piezometer Tube Date 11 12 13 15 18 19 20 21 22 23 24 25 26 27 28 29 30 03/02/13 464+/-197

<319

<314

<314

<318

<318

<327

<327 03/10/13

<328 03/11411 3 03/22/1.

<322 03122/13 04121/13

<327

<327

<332

<319

<325 04/21113 06/25/13 952 +/- 211

<336

<336

<332 1030 +/- 209

<342

<342

<332

<332

<332

<332

<340

<340 08/05/13 11/10/13 1280 +/-202

<314

<313

<313

<315

<315

<321

<321

<317 12/7/13

<305

<306

<307

<305

<307

<306

<304 12/24/13

<313 10

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 Gross Concentration of Gamma Emitters (Results in units of pCi/L +1-20)

Piezometer Tube

  • All Non-Natural Gamma Emitters < MDA 11

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 VI.

BATCH RELEASES A.

Liquid

1. Number of batch releases
2. Total time period for batch releases (min)
3. Maximum time period for a batch release (min)
4. Average time period for batch releases (min)
5. Minimum time period for a batch release (min)
6. Average stream flow during periods of effluent into a

flowing stream (liters/min of dilution water)

B.

Gaseous

1. Number of batch releases
2. Total time period for batch releases (min)
3. Maximum time period for a batch release (min)
4. Average time period for batch release (min)
5. Minimum time period for a batch release (min)

IST QUARTER 16 6.33E+03 6.55E+02 3.96E+02 2.OOE+01 4.45E+06 1ST QUARTER 24 1.03E+04 2.36E+03 4.29E+02 4.70E+01 2013 2ND 3RD QUARTER QUARTER 13 12 4.55E+03 4.82E+03 6.09E+02 7.1OE+02 3.50E+02 4.02E+02 2.OOE+01 1.80E+01 4.60E+06 4.57E+06 4TH QUARTER 10 6.11 E+03 7.17E+02 6.11E+02 5.31 E+02 4.59E+06 4TH QUARTER 18 6.45E+03 5.08E+02 3.58E+02 1.52E+02 2ND QUARTER 24 9.45E+03 1.44E+03 3.94E+02 4.OOE+00 3RD QUARTER 26 8.44E+03 7.45E+02 3.25E+02 2.OOE+00 "12

ENCLOSURE (1)

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION -

2013 VII.

ABNORMAL RELEASES 2013 1ST 2ND 3RD 4TH QUARTER QUARTER QUARTER QUARTER A.

Liquid

1. Number of releases 2. Total activity released (Curies) B.

Gaseous

1. Number of releases 2. Total activity releases (Curies) 13

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE JA - REG GUIDE 1.21 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES 1ST 2ND 3RD 4TH EST. TOTAL A.

FISSION AND ACTIVATION GASES UNITS QUARTER QUARTER QUARTER QUARTER ERROR, %

1.

Total Release Ci 5.83E+01 2.99E+00 5.67E+00 1.47E+00

+/-1.20E+01

2.

Average release rate for period

[iCi/sec 7.39E+00 3.80E-01 7.19E-01 1.87E-01

3.

Percent of ODCM limit (1) 1.57E-02 2.35E-03 4.63E-03 3.13E-03

4.

Percent of ODCM limit (2) 8.20E-02 7.98E-02 1.93E-05 7.08E-03

5.

Percent of ODCM limit (3) 5.44E-03 5.88E-04 9.40E-04 8.58E-04

6.

Percent of ODCM limit (4) 2.77E-03 3.03E-03 3.43E-03 3.76E-03

7.

Percent of ODCM limit (5) 1.84E-02 2.23E-03 4.33E-03 1.OOE-03

8.

Percent of ODCM limit (6) 9.21 E-03 1.03E-02 1.24E-02 1.29E-02 B.

IODINES

1.

Total lodine -131 Ci 7.90E-04 2.56E-05 3.30E-05 2.81 E-05

+T6.50E+00

2.

Average release rate for period y.Ci/sec 1.OOE-04 3.25E-06 4.18E-06 3.57E-06

3.

Percent of ODCM limit (7) 7.73E-03 2.39E-03 3.89E-03 3.23E-03

4.

Percent of ODCM limit (8) 1.19E-01 4.57E-03 7.39E-03 5.58E-03

5.

Percent of ODCM limit (9) 5.95E-02 7.43E-02 7.89E-02 8.07E-02 C.

PARTICULATES

1.

Particulates with half lives greater than 8 days Ci 3.09-06 (10)

(10)

(10)

+/-1.20E+01

2.

Average release rate for period gjCi/sec 3.92E-07 (10)

(10)

(10)

3.

Percent of ODCM limit (7) 9.59E-02 (10)

(10)

4.

Percent of ODCM limit (8) 1.19E-01 (10)

(10)

(10)

5.

Percent of ODCM limit (9) 5.95E-02 (10)

(10)

(10)

D.

TRITIUM 1.

Total Release Ci 2.25E+00 2.57E+00 3.62E+00 2.50E+00

+/-1.32E+0

2.

Average release rate for period jiCi/sec 2.85E-01 3.26E-01 4.59E-01 3.18E-01 D.

GROSS ALPHA

1.

Total Release Ci 3.83E-07 (10)

(10) 9.55E-07

+/-2.50E+01 1

2.

Average release rate for period I 4Ci/sec I 4.86E-08 1

(10)

I (10) 1.21E-07 I

A-1

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE 1A - REG GUIDE 1.21 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES NOTES TO TABLE 1A (1)

Percent of I.A.1 whole body dose rate limit (500 mrem/year)

(2)

Percent of I.A.1 skin dose rate limit (3000 mrem/year)

(3)

Percent of I.A.3 quarterly gamma-air dose limit (10 mRad)

(4)

Percent of I.A.3 yearly gamma-air dose limit (20 mRad)

(5)

Percent of I.A.3 quarterly beta-air dose limit (20 mRad)

(6)

Percent of I.A.3 yearly beta-air dose limit (40 mRad)

(7)

Percent of organ dose rate limit (1500 mrem/year)

(8)

Percent of I.B.3 quarterly organ dose limit (15 mrem)

(9)

Percent of I.B.3 yearly organ dose limit (30 mrem)

(10) Less than minimum detectable activity which meets the lower limit of detection (LLD) requirements of ODCM Surveillance Requirement 4.11.2.1.2.

A-2

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE IC - REG GUIDE 1.21 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES CONTINUOUS MODE BATCH MODE 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH UNITS QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER FISSION AND ACTIVATION GASES Argon

-41 Ci (2)

(2)

(2)

(2) 2.63E-02 3.39E-02 2.48E-02 2.41 E-02 Krypton

-85 Ci 2.43E+01 (2) 1.33E-01 (2) 6.49E+00 2.85E+00 4.71 E+00 7.26E-01 Krypton

-85m Ci (2)

(2)

(2)

(2)

(2) 5.79E-06 1.06E-05 (2)

Krypton

-87 Ci (2)

(2)

(2)

(2)

(2) 2.75E-05 (2)

(2)

Krypton

-88 Ci (2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

Xenon

-131m Ci (2)

(2)

(2)

(2) 7.57E-03 (2) 2.24E-04 (2)

Xenon

-133 Ci 2.62E+01 (2) 4.92E-01 2.96E-01 1.35E-01 1.34E-02 4.56E-02 4.10E-02 Xenon

-133m Ci 1.30E-01 (2)

(2)

(2) 8.13E-05 (2)

(2)

(2)

Xenon

-135 Ci 9.39E-01 9.65E-02 2.60E-01 3.85E-01 1.80E-04 4.02E-04 7.43E-04 3.32E-04 Xenon

-135m Ci (2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

Xenon

-138 Ci (2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

Total for Period Ci 5.16+01 9.65E-02 8.85E-01 6.81 E-01 6.66E+00 2.90E+00 4.78E+00 7.92E-01 2

IODINES Iodine

-131 Ci 7.90E-04 2.56E-05 3.30E-05 2.81E-05 (1)

(1)

(1)

(1)

Iodine

-132 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

Iodine

-133 Ci 1.92E-04 4.62E-05 4.21E-04 2.89E-04 (1)

(1)

(1)

(1)

Iodine

-135 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Total for Period Ci 9.82E-04 7.18E-05 4.54E-04 3.17E-04 (1)

(1)

(1)

(1) 3 PARTICULATES (half life > 8 days)

Manganese

-54 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Iron

-55 Ci (2)

(2)

(2)

(2)

(1)1) 1 Iron

-59 Ci (2)

(2)

(2)

(2)1 11 Cobalt

-58 Ci (2)

(2)

(2)

(2)1 Cobalt

-60 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

Zinc

-65 Ci (2)

2)

(2)

(2)

(1)

(1) 1 Strontium

-89 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1) 1 A-3

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE IC - REG GUIDE 1.21 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES CONTINUOUS MODE BATCH MODE 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH UNITS QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER Strontium

-90 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Molybdenum

-99 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Cesium

-134 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Cesium

-137 Ci (2)

(2)

(2)

(2) 3.09E-06 (1)

(1)

(1)

Cerium

-141 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Cerium

-144 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

Total for period Ci (2)

(2)

(2)

(2) 3.09E-06 (1)

(1)

(1) 4 GROSS ALPHA RADIOACTIVITY Gross Alpha Ci 3.83E-07 (2)

(2) 9.55E-07 (2)

(2)

(2)

(2) 5 TRITIUM Tritium Ci 2.25E+00 2.57E+00 3.62E+00 2.50E+00 6.54E-07 (2)

(2)

(2)

NOTES TO TABLE 1C (1) lodines and particulates in batch releases are accounted for with the main vent continuous samplers when the release is made through the plant main vent.

(2)

Less than minimum detectable activity which meets the LLD requirements of ODCM Surveillance Requirement 4.11.2.1.2.

A-4

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE 2A - REG GUIDE 1.21 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 1ST 2ND 3RD 4TH EST. TOTAL UNITS QUARTER QUARTER QUARTER QUARTER ERROR, %

A.

FISSION AND ACTIVATION PRODUCTS

1.

Total Release (not including tritium, gases, alpha)

Ci 3.46E-03 3.30E-03 4.29E-03 3.66E-03

+/-1.03E+01

2.

Average diluted concentration during gtCi/ml period 1.62E-12 1.35E-12 1.74E-12 1.49E-12

3.

Percent of ODCM limit (1) 4.05E-03 2.91 E-03 5.05E-03 5.99E-03

4.

Percent of ODCM limit (2) 2.55E-03 3.19E-03 4.87E-03 6.78E-03

5.

Percent of ODCM limit (3) 1.05E-02 5.60E-03 1.14E-02 1.39E-02

6.

Percent of ODCM limit (4) 6.09E-03 7.52E-03 1.31 E-02 1.99E-02 B.

TRITIUM

1.

Total Release Ci 1.90E+02 1.33E+02 3.05E+02 3.70E+02

+/-1.03E+01

2.

Average diluted concentration during gCi/ml period 8.88E-08 5.43E-08 1.24E-07 1.50E-07

3.

Percent of applicable limit (5) 2.96E-03 1.81E-03 4.13E-03 5 5.00E-03 C.

DISSOLVED AND ENTRAINED-GASES

1.

Total Release Ci__

1.OOE-02 1.51 E-06 7.29E-04 1.27E-03

+/-1.03E+01

2.

Average diluted concentration during tCi/ml period 4.70E-12 6.18E-16 2.96E-13 5.18E-13 D.

GROSS ALPHA RADIOACTIVITY

1. Total Release I

Ci (6)

(6)

(6)

(6)

N/A E.

VOLUME OF WASTE RELEASED (prior to dilution)

1.

Volume processed through radwaste system liters 9.79E+07 1.01E+08 9.09E+07 1.23E+08

+/-1.30E+00 F.

VOLUME OF DILUTION WATER USED DURING PERIOD (7) liters 2.14E+12 2.45E+12 2.46E+12 2.46E+12

+/-1.64E+01 (1)

(2)

(3)

(4)

NOTES TO TABLE 2A Percent of I.C.3 Quarterly Organ Dose Limit (10 mrem) to maximum exposed organ Percent of l.C.3 Yearly Organ Dose Limit (20 mrem) to maximum exposed organ Percent of I.C.3 Quarterly Whole Body Dose Limit (3 mrem)

Percent of I.C.3 Yearly Whole Body Dose Limit (6 mrem)

A-5

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 (5)

Limit used is 3 x 10-3 ICi/ml (6)

Less than minimum detectable activity which meets the LLD requirements of ODCM Surveillance Requirement 4.11.1.1.1.

(7)

Includes dilution water used during continuous discharges.

(8)

Liquid releases are higher than normal during refueling outages due to noble gases released from failed fuel A-6

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE 2B - REG GUIDE 1.21 LIQUID EFFLUENTS CONTINUOUS MODE BATCH MODE 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH NUCLIDES RELEASED Units QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER Beryllium - 7 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Sodium-24 Ci (1)

(1)

(1)

(1)

(1)

A1)

11)

(1)

Chromium-51 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

_1 Manganese - 54 Ci (1)

(1)

(1)

(1) 3.72E-06 (1)

(1)

(1)

Iron - 55 Ci (2)

(2)

(2)

(2)

(1)

(1)

(1) 1.52E-03 Cobalt-57 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Cobalt-58 Ci (1)

(1)

(1)

(1) 9.02E-04 2.08E-03 5.07E-04 (1)

Iron - 59 Ci (1)

(1)

(1)

(1) 1.46E-06 (1)

(1) 1 Cobalt-60 Ci (1)

(1)

(1)

(1) 1.61E-04 1.08E-04 3.91E-05 3.65E-04 Nickel-63 Ci (1)

(1)

(1)

(1) 1.50E-03 (1) 8.09E-04 1.51E-03 Zinc-65 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Strontium - 89 Ci (i)

(1)

(1)

(1)

(1)

(1)

(1)

_1)

[Strontium - 90 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1) j1)

!Strontium - 91 Ci (1)

(1)

(1)

(1)

(1) 1 (1 )

(1)

Strontium - 92 Ci (1)

(1)

(1)

(1)

(1) 1 L (1)

_1 Niobium-95 Ci (1)

(1)

(1)

(1) 4.77E-06 1.98E-06 (1)

(1)

Zirconium - 95 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Niobium-97 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Zirconium-97 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Molybdenum-99 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Technetium - 99m Ci (1)

(1)

(1)

1)

(1)

(

(1)

(1)

Ruthenium - 103 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Rhodium - 105 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Ruthenium - 105 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

U1)

Silver-110m Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Tin - 113 Ci (1)

(1)

(1 (1(1)

(1)

(1)

(1)

(1)

Tin - 117m Ci (1)

(1)

(1)

(1) j1)

(1)

(1)

(1)

Antimony - 122 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Antimony - 124 Ci (1)

(1)

(1)

(1)

(1) r:

(1)

(1)

(1)

Antimony-125 Ci (1)

(1)

(()

(1) 1.22E-04 2.80E-04 1.33E-03 (1)

A-7

APPENDIX A ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT FOR CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION - 2013 TABLE 2B - REG GUIDE 1.21 LIQUID EFFLUENTS CONTINUOUS MODE BATCH MODE 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH NUCLIDES RELEASED Units QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER QUARTER Tellurium - 125m Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Tellurium - 132 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Iodine - 131 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Iodine-132 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Iodine-133 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Iodine-135 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Cesium - 134 Ci (1)

(1)

(1)

(1) 8.68E-05 1.14E-04 1.66E-04 (1)

Cesium - 136 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Cesium - 137 Ci (1)

(1)

(1)

(1) 6.78E-04 7.15E-04 1.45E-03 2.62E-04 Barium - 140 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Lanthanum - 140 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Cerium - 144 Ci

01)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Europium - 154 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Europium - 155 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Tungsten - 187 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Total For Period Ci (1)

(1)

(1)

(1) 3.46E-03 3.30E-03 4.29E-03 3.66E-03 Krypton -85 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

A1)

Xenon-131 m Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Xenon -133 Ci (1)

(1)

(1)

(1) 1.OOE-02 1.51E-06 7.29E-04 1.27E-03 Xenon - 133m Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Xenon -135 Ci (1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

Total For Period Ci (1)

(1)

(1)

(1) 1.OOE-02 1.51 E-06 7.29E-04 1.27E-03 NOTES TO TABLE 2B (1)

Less than minimum detectable activity which meets the LLD requirements of ODCM Surveillance Requirement 4.11.1.1.1.

(2)

Continuous mode effluents are not analyzed for Fe-55.

A-8

APPENDIX A CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION EFFLUENT AND WASTE DISPOSAL 2013 ANNUAL REPORT TABLE 3A SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL)

1. Type of Waste Units 12-Month Period Est. Total Error %

a)

Spent resins, Filters m3 3.13+01 25%

Ci 1.1OE+03 b)

Dry compressible m3 1.91 E+03 25%

waste, contaminated Ci 1.75E+00 equipment, etc.

c)

Irradiated m3 0.00E+00 N/A components, control Ci 0.OOE+00 rods, etc.

d)

Other (cartridge m3 7.OOE+00 25%

filters, misc.

dry Ci 2.OOE+00 compressible, Oil) e)

Solidification agent m3 N/A N/A or absorbent Volume shipped represents waste generated prior to offsite volume reduction.

2.

Estimate of Major Nuclides (By Type of Waste - Only nuclides >1 % are reported) a)

Mn-54 1.2%

Fe-55 18.4%

Co-58 1.13%

Co-60 8.80%

Ni-63 54.5%

Cs-1 34 4.20%

Cs-137 11.8%

b)

Cr-51 5.0%

Fe-55 21.6%

Co-58 15.5%

Co-60 15.2%

Ni-63 17.2%

Ag-110m 1.4%

Cs-134 7.8%

Cs-137 16.2%

c)

N/A d)

Cr-51 3.3%

Fe-55 22.1%

Co-58 17.7%

Co-60 16.5%

Ni-63 25.6%

Cs-134 4.4%

Cs-137 9.8%

e)

N/A A-9

APPENDIX A CALVERT CLIFFS NUCLEAR POWER PLANT AND INDEPENDENT SPENT FUEL STORAGE INSTALLATION EFFLUENT AND WASTE DISPOSAL 2013 ANNUAL REPORT

3.

Solid Waste Disposition Number of Shipments Mode of Transportation Destination 47 Motor Surface Transit Studsvik Processing Facility Memphis, TN 11 Motor Surface Transit Studsvik Processing Facility 2

Motor Surface Transit B.

IRRADIATED FUEL SHIPMENTS (DISPOSITION) N/A Erwin, TN Energy Solutions (Duratek)

Oak Ridge, TN A-10