APPENDIX B Southern California Edison Company P. 0. Box 800 Rosemead, California 91770 Docket Nos.

50-361 and 50-362 Construction Permit Nos.

CPPR-97 and CPPR-98 Notice of Deviation Based on the results of an NRC inspection conducted on March 3-17 and 21-28, 1980, it appears that one of your activities was not conducted in accordance with your commitments in Appendix 3A of the FSAR which states that the "Quality Program for safety-related items during receiving, storage, and handling of nuclear system components at the jobsite is in accordance with ANSI-N45.2.2-1972 as interpreted by Regulatory Guide 1.38."

The SCE QA Manual,Chapter 13, Handling, Packaging, Storage, Shipping, Preservation and Cleaning and the Bechtel Project Quality Program Manual, Chapter 13 both reference the requirements of ANSI N45.2.2. ANSI N45.2.2, Section 3.3.4.(3) states in part "Items subject to detrimental corrosion, either internally or externally shall be suitably protected".

Contrary to the above, high strength bolts were observed on March 5 to be stored in several five-gallon buckets partially filled with rain water.

This is a deviation.

so ovett