MONTHYEARBW110021, Response to NRC Verification Inspection Report; 05000456/2011009; 05000457/20110092011-03-0202 March 2011 Response to NRC Verification Inspection Report; 05000456/2011009; 05000457/2011009 Project stage: Request ML1117900402011-04-12012 April 2011 Westinghouse Electric Company Affidavit Supporting Withholding, Attachment 6 to Braidwood Station, Units 1 & 2, Byron Station, Unit 1 & 2, Request for License Amendment Regarding Measurement Uncertainty Recapture (MUR) Power Uprate Project stage: Request ML1117900432011-05-0909 May 2011 Affidavit from Cameron International Corporation Supporting Withholding of Attachments 8a Through 8d Project stage: Request ML1117900422011-06-21021 June 2011 MUR Technical Evaluation, (Non-Proprietary Version), Attachment 7 to Braidwood Station, Units 1 & 2, Byron Station, Unit 1 & 2, Request for License Amendment Regarding Measurement Uncertainty Recapture (MUR) Power Uprate Project stage: Request ML1117900382011-06-23023 June 2011 Steam Generator Tube Rupture Analysis Report, Attachment 5a to Braidwood Station, Units 1 & 2, Byron Station, Unit 1 & 2, Request for License Amendment Regarding Measurement Uncertainty Recapture (MUR) Power Uprate Project stage: Request RS-11-099, Request for License Amendment Regarding Measurement Uncertainty Recapture (MUR) Power Uprate2011-06-23023 June 2011 Request for License Amendment Regarding Measurement Uncertainty Recapture (MUR) Power Uprate Project stage: Request ML11224A0832011-08-0303 August 2011 NRR E-mail Capture - Draft - Supplemental Information Request Braidwood and Byron MUR LAR (ME6587-ME6590) Project stage: Draft Approval ML1121505632011-08-22022 August 2011 Supplemental Information Needed for Acceptance of Licensing Action Measurement Uncertainty Recapture Power Uprate Project stage: Acceptance Review ML11266A0022011-09-19019 September 2011 NRR E-mail Capture - Draft RAI Braidwood/Byron - Measurement Uncertainty Recapture LAR Project stage: Draft RAI ML1122315742011-09-19019 September 2011 Acceptance Review of License Amendment Request (LAR) Measurement Uncertainty Recapture (MUR) Power Uprate Project stage: Acceptance Review ML11262A1612011-10-12012 October 2011 Request for Addtional Information Measurement Uncertainty Power Uprate Request Project stage: Other RS-11-169, Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2011-11-0101 November 2011 Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Request ML1129305492011-11-0303 November 2011 Request for Withholding Information from Public Disclosure Affidavit CAW-11-03 Project stage: Withholding Request Acceptance ML1129203422011-11-0303 November 2011 Request for Withholding Information from Public Disclosure Affidavit CAW-11-3137 Project stage: Withholding Request Acceptance ML1130104032011-11-28028 November 2011 Request for Additional Information 2 Measurement Uncertainty Power Uprate Request Project stage: RAI ML1202609362012-02-14014 February 2012 Request for Additional Information Measurement Uncertainty Recapture Power Uprate Request Project stage: RAI ML1202701462012-02-14014 February 2012 Request for Additional Information Measurement Uncertainty Recapture Power Uprate Request Project stage: RAI ML1205302582012-02-24024 February 2012 Request for Additional Information Measurement Uncertainty Recapture Power Uprate Request Project stage: RAI ML12068A3822012-03-0808 March 2012 E-MAIL - MUR LAR 1 Response Date Project stage: Approval ML12068A2942012-03-0808 March 2012 Request for Additional Information Regarding Reactor Systems MUR Review (TACs ME6587, ME6588, ME6589, and ME6590) Project stage: RAI ML1205904602012-03-0909 March 2012 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML12089A4902012-03-29029 March 2012 E-MAIL - Draft Balance of Plant Request for Additional Information for MUR Review Project stage: Draft RAI ML12121A6942012-05-10010 May 2012 Request for Additional Information Related to License Application for Measurement Uncertainty Recapture Uprate Project stage: RAI RS-12-081, Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2012-05-16016 May 2012 Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Request ML12157A0632012-06-13013 June 2012 Request for Additional Information Related to Measurement Uncertainty Recapture Uprate Project stage: RAI ML12233A6012012-08-27027 August 2012 Request for Additional Information, Measurement Uncertainty Recapture Power Uprate Request Project stage: RAI RS-12-144, Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2012-09-13013 September 2012 Additional Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Request ML12216A0002012-09-27027 September 2012 Request for Additional Information Related to Measurement Uncertainty Uprate Project stage: RAI ML12271A3082012-12-0606 December 2012 Request for Additional Information and Suspension of Review of License Amendment Request for Power Uprate Project stage: RAI RS-13-227, Response to NRC HELB Audit Request for Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2013-09-0505 September 2013 Response to NRC HELB Audit Request for Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Request RS-13-261, Supplemental Response to NRC HELB Audit Request for Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2013-10-24024 October 2013 Supplemental Response to NRC HELB Audit Request for Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Supplement RS-13-267, Supplemental Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate2013-11-13013 November 2013 Supplemental Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Supplement 2012-02-14
[Table View] |
Text
ti November 13, 2013 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Units 1 and 2 Facility Operating License Nos. NPF-72 and NPF*77 NRC Docket Nos. STN 50-456 and STN 50-457 Byron Station, Units 1 and 2 Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455 10 CFR 50.90
Subject:
Supplemental Information Supporting Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate
References:
- 1. Letter from Craig Lambert (Exelon Generation Company, LLC) to U. S. NRC, "Request for License Amendment Regarding Measurement Uncertainty Recapture Power Uprate," dated June 23, 2011
- 2. Letter from Nicholas J. DiFrancesco (U. S. NRC) to M. J. Pacilio (Exelon Generation Company, LLC), "Braidwood Station, Units 1 and 2, and Byron Station, Units Nos. 1 and 2 - Acceptance Review of License Amendment Request (LAR) Re: Measurement Uncertainty Recapture (MUR) Power Uprate (TAC Nos. ME6587, ME6588, ME6589, and ME6590)," dated September 19, 2011
- 3. Letter from David M. Gullott (Exelon Generation Company, LLC) to
- u. S. NRC, "Response to a Request for Voluntary Response to Petition From Barry Quigley Regarding Byron Station, Unit Nos. 1 and 2, and Braidwood Station, Units 1 and 2 High-Energy Line Break Analysis," dated August 31,2012 In Reference 1, Exelon Generation Company, LLC (EGG) requested an amendment to Facility Operating License Nos. NPF-72, NPF-77, NPF-37 and NPF*66 for Braidwood Station, Units 1 and 2, and Byron Station, Units 1 and 2, respectively. Specifically, the proposed changes revise the Operating License and Technical Specifications to implement an increase in rated thermal power of approximately 1.63% based on increased feedwater flow measurement accuracy.
In Reference 2, the NRC staff indicated that the satisfactory disposition of the known nonconformance with turbine building (TB) high-energy line break (HELB) would be required prior to implementation. Additionally on July 17, 2013 the NRC conducted an
November 13, 2013 U.S. Nuclear Regulatory Commission Page 2 Audit regarding the new TB HELB analysis and planned TB HELB modifications that were in the process of being installed to support that analysis.
The purpose of this letter is to confirm that the physical modifications to resolve the non-conformances and restore the design basis for the TB H ELB have been completed at both Braidwood and Byron Stations. The existing Operability Evaluations pertaining to the TB H ELB non-conformance have been closed at both Braidwood and Byron Stations. These closed Operability Evaluations, provided to the NRC in Reference 3, are listed below.
Braidwood Operability Evaluation 11-006: Turbine Building EHLB Analysis Input Errors Operability Evaluation 12-004: HELB Load Not Considered in Structural Calculation Operability Evaluation 11-005: Turbine Building HELB Analysis Input Errors Operability Evaluation 12-005: HELB Load Not Considered in Structural Calculation Subsequent to submittal of Reference 3, Byron Station initiated an additional Operability Evaluation,13-002, Unit 1 Emergency Diesel Generator Rolling Steel Door Supports, which was related to the TB HELB analysis. This Operability Evaluation has also been closed.
There are no regulatory commitments contained in this letter.
Should you have any questions concerning this letter, please contact Leslie E. Holden at (630) 657-3316.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 13th day of November 2013.
Respectfully, David M. Gullott Manager - Licensing Exelon Generation Company, LLC cc:
NRC Regional Administrator, Region III NRC Senior Resident Inspector, Braidwood Station NRC Senior Resident Inspector, Byron Station