JUL 2 9 1983 Docket Nos.: 50-361 and 50-362 Mr. Robert Dietch Mr. James C. Holcombe Vice President San Diego Gas & Electric Company Southern California Edison.Company 101 Ash Street 2244 Walnut Grove Avenue Post Office Box 1831 Post Office Box 800 San Diego, California 92112 Rosemead, California 91770 Gentlemen:

Subject:

San Onofre 2 Turbine Trip Test The staff has reviewed your submittal of July 14, 1983, which requests approval of a modification to the San Onofre, Unit 2, startup test program.

The modification would remove a planned 100% (power) turbine trip test from the Power Ascension Testing Sequence. As discussed in the enclosure, we find this modification acceptable, provided that the 100% load rejection (generator) trip test is conducted as planned and that the startup test report verify that all generator trips directly initiate turbine trip.

Sincerely, Original signed by:

Harry Rood jrIGeorge W. Knighton, Chief Licensing Branch No. 3 Division of Licensing

Enclosure:

As stated cc w/enclosure:

See next page Distribution:

Oocument Control 50-361/362

/ NRC PDR L PDR PRC System NSIC LB#3 ReAding File JTaylor, IE TNovak EJordan, IE GKnighton ACRS (16)

HRood JLee DL:LB DLB#308100036 830729 OFFICEO D:L#3 XlW DL: LB#3 PDR ADOCK 05000361............................

0FE............

PD ADC 050031 SURNAMEO HRood:ph GKnighton DATEN 731/8 7/I/8 3

NRC FORM 318 (10/80) NRCM 0240 OFFICIAL, RECORD COPY

  • U.S.G&O 1983-400-247

San Onofre Mr. Robert Dietch Vice President Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Mr. Jaies C. Holcombe Vice President - Power Supply San Diego Gas & Electric Company 101 Ash Street Post Office Box 1831 San Diego, California 92112 cc:

Charles R. Kocher, Esq.

Mr. Mark Medford James A. Beoletto, Esq.

Southern California Edison Company Southern California Edison Company 2244 Walnut Grove Avenue 2244 Walnut Grove Avenue P. 0. Box 800 P. 0. Box 800 Rosemead, California 91770 Rosemead, California 91770 M-r.

Henry Peters Orrick, Herrington & Sutcliffe San Diego Gas & Electric Company ATTN:

David R. Pigott, Esq.

P. 0. Box 1831 600 Montgomery Street San Diego, California 92112 San Francisco, California 94111 Ms. Lyn Harris Hicks Mr. George Caravalho Advocate for GUARD City Manager 3908 Calle Ariana City of San Clemente San Clemente, California 92672 100 Avenido Presidio San Clemente, California 92672 Richard J. Wharton, Esq.

University of San Diego School of Law Alan R. Watts, Esq.

Environmental Law Clinic Rourke & Woodruff San Diego, California 92110 Suite 1020 1055 North Main Street Phyliis M. Gallagher, Esq.

Santa Ana, California 92701 Suite 222 1695 West Crescent Avenue Lawrence Q.

Garcia, Esq..

Anaheim, California 92701 California Public Utilities Commission 5066 State Building Mr. A. S. Carstens San Francisco, California 94102 2071 Caminito Circulo Norte Mt. La Jolla-, California 92037 Mr. V. C. Hall Combustion Engineering, Inc.

Charles E. McClung, Jr., Esq.

1000 Prospect Hill Road Attorney at Law Windsor, Connecticut '06095 24012 Calle de la Plata/Suite 330

.-.Laguna-lHfills, California _92653 Mr. S. McClusky Bechtel Power Corporation Resident Inspector, San Onofre/NPS P. 0. Box 60860, Terminal Annex do U.S. Nuclear Regulatory Commission Los Angeles, California 90060 P. 0. Box 4329 San Clemente, California 92672 Mr. Dennis F. Kirsch U.S. Nuclear Regulatory Comm. - Reg. V Regional Administrator-Region V/NRC 1450 Maria Lane, Suite 210 1450 Maria Lane/Suite 210 Walnut Creek, California 94596 Walnut Creek, California 94596

SAN ON0FRE Mr. C. B. Brinkman Combustion Engineering, Inc.

7910 Woodmont Avenue Bethesda, Maryland 20814