MONTHYEARML22279A9512022-10-0606 October 2022 Shine Technologies, LLC Request to Amend Construction Permit No. CPMIF-001 ML22091A0932022-04-0101 April 2022 Shine Technologies, LLC Request to Amend Construction Permit No. CPMIF-001 ML21232A6202021-08-20020 August 2021 Shine Medical Technologies, LLC Request to Amend Construction Permit No. CPMIF-001 - Response to Request for Additional Information ML21119A1682021-04-29029 April 2021 Enclosure 2: Request to Amend Construction Permit No. CPMIF-001 ML18347A2152018-12-11011 December 2018 Shine Medical Technologies - Application for Order Approving Indirect Transfer of Control of Construction Permit and Conforming Administrative Construction Permit Amendment ML15247A0672015-09-0202 September 2015 Shine Medical Technologies, Inc. Application for Construction Permit Response to Request for Additional Information ML15258A3692015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 01 - the Facility ML15258A4302015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.5.2-006 Through 19.5.2-009 ML15258A4292015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.5.2-001 Through 19.5.2-005 ML15258A4282015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.4.1-001 Through 19.4.13-001 ML15258A4262015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.4-001 Through 19.3.4-008 ML15258A4242015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.3-001 Through 19.3.3-007 ML15258A4232015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.2-001 Through 19.3.2-036 ML15258A4222015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.1-007 Through 19.3.1-009 ML15258A4202015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.2.1-001 Through 19.2.3-001 ML15258A4182015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.07 - References ML15258A4172015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.06 - Conclusions ML15258A4162015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.05 - Alternatives ML15258A4152015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.04 - Impacts of Proposed Construction, Operations, and Decommissioning ML15258A4142015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.03 - Description of the Affected Environment ML15258A4132015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.02 - Proposed Action ML15258A4122015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.01 - Introduction to the Environmental Report ML15258A4192015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Environmental Review ML15258A4112015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 12 - Figure 12.1-001 ML15258A4102015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 11 - Figures 11.1-001 and 11.1-003 ML15258A4092015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Figures 9b.2-001 Through 9b.7-008 ML15258A4082015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Figures 9a2.1-001 Through 9a2.7-001 ML15258A4072015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001 ML15258A4062015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.1-001 ML15258A4042015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002 ML15258A3892015-08-27027 August 2015 Shine Medical Technologies V. 0 - PSAR Master Table of Contents ML15258A3702015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Site Characteristics ML15258A3902015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 01 - Figures 1.3-001 Through 1.3-006 ML15258A3912015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.1-001 Through 2.1-026 ML15258A3922015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.2-001 Through 2.2-002 ML15258A3932015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.3-001 Through 2.3-036 ML15258A3982015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.5-007 Through 2.5-023 ML15258A3712015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 03 - Design of Structures, Systems, and Components ML15258A3722015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Irradiation Unit and Radioisotope Production Facility Description ML15258A3732015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 05 - Cooling Systems ML15258A3742015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 06 - Engineered Safety Features ML15258A3752015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Instrument and Control Systems ML15258A3782015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Electrical Power Systems ML15258A3792015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Auxiliary Systems ML15258A3812015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 11 - Radiation Protection Program and Waste Management ML15258A4052015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Figure 7b.2-001 ML15258A4032015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 05 - Figures 5a2.1-001 Through 5a2.4-001 ML15258A4022015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Figures 4b.3-001 Through 4b.4-007 ML15258A4002015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Figures 4a2.1-001 Through 4a2.8-002 ML15258A3992015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 03 - Figures 3.4-001 Through 3.4-014 2022-04-01
[Table view] Category:Preliminary Safety Analysis Report (PSAR)
MONTHYEARML15258A3692015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 01 - the Facility ML15258A5322015-08-27027 August 2015 Enclosure 1, Attachment 1 - Preliminary Safety Analysis Report Changes Markups ML15258A5332015-08-27027 August 2015 Enclosure 1 - Update to the Evaluation of Aircraft Hazard and the Evaluation of Chemical Hazards Provided in the Preliminary Safety Analysis Report ML15258A5972015-08-27027 August 2015 Enclosure 2, Attachment 2 - Preliminary Safety Analysis Report Changes (Markup) ML15258A3892015-08-27027 August 2015 Shine Medical Technologies V. 0 - PSAR Master Table of Contents ML15258A4302015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.5.2-006 Through 19.5.2-009 ML15258A4292015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.5.2-001 Through 19.5.2-005 ML15258A4282015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.4.1-001 Through 19.4.13-001 ML15258A4262015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.4-001 Through 19.3.4-008 ML15258A4242015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.3-001 Through 19.3.3-007 ML15258A4232015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.2-001 Through 19.3.2-036 ML15258A4222015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.3.1-007 Through 19.3.1-009 ML15258A4202015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Figures 19.2.1-001 Through 19.2.3-001 ML15258A4182015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.07 - References ML15258A4172015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.06 - Conclusions ML15258A4162015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.05 - Alternatives ML15258A4152015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.04 - Impacts of Proposed Construction, Operations, and Decommissioning ML15258A4142015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.03 - Description of the Affected Environment ML15258A4132015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.02 - Proposed Action ML15258A4122015-08-27027 August 2015 Shine Medical Technologies V. 0 - Section 19.01 - Introduction to the Environmental Report ML15258A4192015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 19 - Environmental Review ML15258A4112015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 12 - Figure 12.1-001 ML15258A4102015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 11 - Figures 11.1-001 and 11.1-003 ML15258A4092015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Figures 9b.2-001 Through 9b.7-008 ML15258A4082015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Figures 9a2.1-001 Through 9a2.7-001 ML15258A4072015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001 ML15258A4062015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.1-001 ML15258A4052015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Figure 7b.2-001 ML15258A4032015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 05 - Figures 5a2.1-001 Through 5a2.4-001 ML15258A3702015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Site Characteristics ML15258A3902015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 01 - Figures 1.3-001 Through 1.3-006 ML15258A3912015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.1-001 Through 2.1-026 ML15258A4042015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002 ML15258A3922015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.2-001 Through 2.2-002 ML15258A3932015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.3-001 Through 2.3-036 ML15258A3982015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 02 - Figures 2.5-007 Through 2.5-023 ML15258A3712015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 03 - Design of Structures, Systems, and Components ML15258A3722015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Irradiation Unit and Radioisotope Production Facility Description ML15258A3732015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 05 - Cooling Systems ML15258A3742015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 06 - Engineered Safety Features ML15258A3752015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 07 - Instrument and Control Systems ML15258A3782015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 08 - Electrical Power Systems ML15258A3802015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 10 - Experimental Facilities ML15258A4022015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Figures 4b.3-001 Through 4b.4-007 ML15258A4002015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 04 - Figures 4a2.1-001 Through 4a2.8-002 ML15258A3792015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 09 - Auxiliary Systems ML15258A3992015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 03 - Figures 3.4-001 Through 3.4-014 ML15258A3882015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 18 - Highly Enriched to Low Enriched Uranium Conversion ML15258A3872015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 17 - Decommissioning and Possession-Only License Amendments ML15258A3852015-08-27027 August 2015 Shine Medical Technologies V. 0 - Chapter 15 - Financial Qualifications 2015-08-27
[Table view] |
Text
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Site Vicinity Map SHINE SITE ROCK RIVER SHINE SITE 1 0 1 SCALE MILES LEGEND REFERENCE
SHINE SITE SHINE Medical Technologies Rev. 0
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Map of Physiographic Sections SHINE Medical Technologies Rev. 0
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Tectonic Provinces Map ARCHEAN AND PALEOPROTEROZOIC GEOLOGIC PROVINCES LATE PROTEROZOIC AND MESOPROTEROZOIC GEOLOGIC PROVINCES e e Lak erior Lak erior Sup Sup Lake Lake Huron Huron RQ MCR Lake MCR Michigan CPO EGR 186 0 186 300 0 300 186 0 186 300 0 300 APPROXIMATE SCALE MILES APPROXIMATE SCALE KM APPROXIMATE SCALE MILES APPROXIMATE SCALE KM LEGEND CENTRAL PLAINS OROGEN (INCLUDES STRATIGRAPHIC CONTACT (DASHED WHERE APPROXIMATED) SHINE SITE YAVAPAI AND MAZATZAL PROVINCES)
HIGH-ANGLE FAULT SUPERIOR PROVINCE STRIKE-SLIP FAULT PREDOMINANT RELATIVE DISPLACEMENT REFERENCE MINNESOTA RIVER PROVINCE THRUST FAULT 1.) SIMS ET AL., 2005.
PENOKEAN OROGEN (INCLUDES PEMBRINE-WAUSAU AND MARSHFIELD TERRANES)
MIDCONTINENT RIFT SOUTHERN GRANITE RHYOLITE PROVINCE EASTERN GRANITE RHYOLITE PROVINCE RHYOLITE-QUARTZ ARENITE BELT SHINE Medical Technologies Rev. 0
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Generalized Regional Geologic Map 93° W 92° W 91° W 90° W 89° W 88° W 87° W 86° W 85° W
( ( ( ( ( ( %
( % % %
( ( ( ( ( (% (% % % % %
( ( ( ( % %
( % % % % %
( ( ( % % % % % % % %
( ( % % % % % % % %
( % % % % % %
( ( ( % % % % %
( ( ( % % % % %
( ( ( ( ( % % % % % % % % %
( ( ( ( % % % % % % % % % %
( ( ( ( ( % % % % % % % % % % %
( ( ( ( % % % % % % % % % % % % % %
( ( ( % % % % % % % % % % % % % %
( ( % % % % % % % % % % % % % %
45° N 45° N Wabasha and Eau Goodhue County %
P leine %
(((( % % % % % % % % % % % % % % % % %
Faults
[ (((((((([ % % % % % % % % % % % % % % % %
S((he
[ (((((((((([ % % % % % % % % % % % % % % % %
(((((((((((((((([ ar Zone %
[ [ [ [ [ (((((([
[ [ [ [ [ % *%
[ [
(((((( [ [ [ (((([
[ %
(((((((( (((((((( %
(((((((([ (((((([ %
(((((((( *
(((((( *
(((([ * *
((((
(
( (
44° N
( (
Houston County
(
Faults (
(
(
(
(
(
(
Mower
( ( * *
( ( (
( ( ( ( ( (
( ( ( ( ( (
( ( ( ( (
(
(
(
(
( ( (
Unamed Fault in Rock County Madison 43° N Lake Michigan 43° N Madison Fault Fa u lt Wa Mineral Point Anticline uk Janesville es e ha rove Anticlin Fault Meekers G
)
G Sy alen nc a lin e 42° N 42° N Zo n e ive r Fault Plum R ok Sa f Co lts Zone nd eo u a ault wic Zon nty Fa an nF hF Am ult linto au Cou ity-C lt Fa Io wa C Zo ne La Sout Sal astI le A en t
41° N he am rium 41° N a e ow Lin nt lino er s
rle ntic s
Fo ld ha R
.C Fa oya St ul l C t e Peoria Folds Wabash Valley 40° N Liquefaction Features 40° N
³ 93° W 92° W 91° W 90° W 89° W 88° W 87° W 86° W LEGEND
)
! SHINE SITE State Boundary 200 Mile (322 KM) Radius Fault and Open Water Fold Trend Geologic Time Generalized Geologic Units 60 30 0 60 Jurassic Mudstone, shale MILES Pennsylvanian Coal, limestone, sandstone, shale or clay shale SCALE Mississippian Limestone, shale or clay shale 100 50 0 100 KM Devonian Carbonate, sandstone SCALE Silurian Dolomite, silty limestone REFERENCE Ordovician Conglomerate, dolomite, limestone, sandstone, shale Bedrock geology map from Garrity and Soller (2009). Geologic GARRITY, C.P., AND SOLLER, D.R., 2009.
units generalized from references cited in report.
Cambrian Dolomite, sandstone, shale
( ( ( ( ( (
Early Proterozoic Quartzite
( ( ( ( ( (
( ( ( ( ( (
( ( ( ( ( (
( ( ( ( ( (
( ( ( ( ( (
Early Proterozoic Felsic Rocks Wolf River Batholith Early Proterozoic Volcanic Rocks Early and Middle Granitic Rocks Proterozoic
(((((((((((([
(((((((((((([
(((((((((((([
Late Archean Orthogneiss
(((((((((((([
SHINE Medical Technologies Rev. 0
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Generalized Regional Structural Geologic Map 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W EAU PLEINE WISCONSIN SHEAR ZONE DOME 44° 0' 0" N WABASHA AND 44° 0' 0" N GOODHUE COUNTY FAULTS W IS S IN HOUSTON COUNTY CON FAULTS T UL BAS F A NTY IN D
H ME OU A RC NA K C MOWER COUNTY FAULTS MINERAL POINT U N R OC HIGA ANTICLINE IN N MADISON FAULT MIC WAUKESHA FAULT MEEKERS GROVE ANTICLINE JANESVILLE 42° 0' 0" N GALENA SYNCLINE FAULT 42° 0' 0" N AMANA KA NE NK FAULT ULT ZO A IVER FA KE PLUM R O NE EA T Z OQUAWKA FAUL RC TON H ANTICLINE - CLIN CIT Y SA SP IOW A ND WI ER CH RY FA ZONE OF BURLINGTON AN AN UL COOK ANTICLINE TZ TI E L L IUM CL ON COUNTY LT R ILLINOIS SA OR IN E VE FA FAULTS IVER A E
RI E U K LIN BASIN LA LIN ER T IC UN IC RCH T CE SK A N T ES NT AS S H E LD RL T HA EN OY U T FO C AL SO W A . AM ST IN E R IP PI R IO L BENTONSPORT MISSIS ANTICLINE 40° 0' 0" N S
PEORIA FOLDS 40° 0' 0" N WABASH VALLEY LIQUEFACTION FEATURES 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W LEGEND SHINE SITE 200 MILE (322 KM) RADIUS REVERSE FAULT (SAWTEETH ON HANGING WALL)
ANTICLINE GENERALIZED DOME AND BASIN SYNCLINE FAULT (HATCHURES ON DOWNTHROW SIDE) 62 0 62 REFERENCES SCALE MILES
100 0 100
! "#! "$ SCALE KM
% &
SHINE Medical Technologies Rev. 0
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering Figure 2.5 Regional Magnetic Anomaly Map and Structural Interpretation 96° 0' 0" W 92° 0' 0" W 88° 0' 0" W 84° 0' 0" W 80° 0' 0" W MCR 44° 0' 0" N 44° 0' 0" N MCR R
MC 40° 0' 0" N 40° 0' 0" N 124 0 124 APPROXIMATE SCALE MILES 200 0 200 APPROXIMATE SCALE KM 96° 0' 0" W 92° 0' 0" W 88° 0' 0" W 84° 0' 0" W LEGEND SHINE SITE MCR MIDCONTINENT RIFT 200 MILE (322 KM) RADIUS HIGH-ANGLE FAULT - CHIEFLY TRANSCURRENT SHEARS AND FAULTS OF LATE PALEOPROTEROZOIC -
MESOPROTERZOIC AGE, BUT INCLUDES FAULTS OF LATE ARCHEAN AGE IN NORTHERN MIDCONTINENT. ARROWS INDICATE RELATIVE DISPLACEMENT WHERE KNOWN. SOLID LINE, BASED CHIEFLY ON GEOLOGIC DATA; DASHED LINE, BASED CHIEFLY ON MAGNETIC DATA. NOTE: SAME DISTINCTION APPLIES TO STRUCTURES FOLLOWING:
DUCTILE SHEAR ZONE; MAINLY OF LATE PALEOPROTEROZOIC AGE BOUNDARY OF MAJOR RIFT ZONE OF LATE MESOPROTEROZOIC (MIDCONTINENT RIFT) AND CAMBRIAN (REELFOOT RIFT) AGE THRUST FAULT OF MESOPROTEROZOIC (~1.1 Ga) AGE THRUST FAULT OF PALEOPROTEROZOIC AGE ASSOCIATED WITH SUTURE ZONES. SOLID LINE, BASED CHIEFLY ON GEOLOGIC DATA; DASHED LINE BASED CHIEFLY ON MAGNETIC DATA.
REFERENCE 1.)
2.) .
SHINE Medical Technologies Rev. 0