ML13169A186
| ML13169A186 | |
| Person / Time | |
|---|---|
| Site: | Byron |
| Issue date: | 04/29/2013 |
| From: | Mcneil D Exelon Nuclear |
| To: | Division of Reactor Safety III |
| References | |
| Download: ML13169A186 (43) | |
Text
Exelon Nuclear Job Performance Measure Excess Letdown Operations JPM Number:
CR a Revision Number: 8 Date:
2/22/2013 Revised By:
Bill Hochstetter Instructor Date 2/22/13 Validated By:
Kelly Wilson Operations Representative Date 03/03/2013 Approved By:
Rob Lawlor Operations Representative nt Date 03/03/2013
CR JPM a.
INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
1CV459 has failed closed and MM are investigating the cause of the failure.
- 3.
Normal charging has been isolated.
- 4.
Reactor power is < 99.5%.
INITIATING CUE
- 1.
The US directs you to establish excess letdown to the VCT using the A loop drain and BOTH letdown heat exchangers for maximum cooling.
- 2.
The SM does NOT desire flow to be directed to the VCT spray nozzle and is aware of the procedural limitations associated with this alignment.
- 3.
Rad Protection has been informed of this evolution.
- 4.
Another NSO will respond to ALL other Control Room annunciators and conditions
CR JPM a.
RECORD START TIME:
ELEMENT SAT STANDARD UNSAT Comment Number
- 1.
Refer to BOP CV-15 Note: May be performed at any time Cue: Prerequisites are met Cue: (if asked) It is not necessary to use an EST
° LOCATE and OPEN BOP CV-15
- 2.
Verify/open 1CV8100
- 1CV8100 is OPEN
- 3.
Verify/open 1CV8112
- 1CV8112 is OPEN
- 4. Establish CC flow to the Excess Letdown Heat Exchangers
- 1CC9437B is OPEN
- 1CC9437A is OPEN
- 5.
Verify closed 1CV123
- 1CV123 is closed
- 6.
Verify/direct flow to VCT
- 1CV8143 selected to VCT
- 7. Open loop drain valve
- Open at least one loop drain valve 1RC8037A,
- 8. Open Excess Ltdn HX inlet valve
- 1CV8153A and B are OPEN
- 9. Open flow control valve and ensure Excess Ltdn outlet temperature stabilizes at <165°F.
- 1CV123 is throttled OPEN
RECORD STOP TIME:
CR JPM a.
INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
1CV459 has failed closed and MM are investigating the cause of the failure.
- 3.
Normal charging has been isolated.
- 4.
Reactor power is < 99.5%.
INITIATING CUE
- 1.
The US directs you to establish excess letdown to the VCT using the A loop drain and BOTH letdown heat exchangers for maximum cooling.
- 2.
The SM does NOT desire flow to be directed to the VCT spray nozzle and is aware of the procedural limitations associated with this alignment.
- 3.
Rad Protection has been informed of this evolution.
- 4.
Another NSO will respond to ALL other Control Room annunciators and conditions.
Exelon Nuclear Job Performance Measure Raise Letdown flow from 75 to 120 gpm JPM Number:
CR JPM b.
Revision Number:
00 Date:
1/24/2013 Revised By:
Bill Hochstetter Instructor Date 1/24/13 Validated By:
Kelly Wilson Operations Dept.
Date 3/3/2013 Approved By:
/s/Rob Lawlor Operations Representative Date 3/3/2013
CR JPM b.
INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
Unit 1 is at 100% power, steady state, equilibrium Xenon, MOL
- 3.
Letdown flow is currently 75 gpm INITIATING CUE
- 1.
You have been directed to raise letdown flow to 120 gallons per minute and then restore systems to automatic in accordance with BOP CV-9, step 2.
- 2.
Inform the US when complete.
- 3.
Another NSO will respond to ALL other Control Room annunciators and conditions.
CR JPM b.
RECORD START TIME:
ELEMENT SAT STANDARD UNSAT Comment Number NOTE If this JPM is performed on the simulator, only the cues underlined are required to be provided to the examinee
- 1. Refer to BOP CV-9, Letdown Orifice Operation Note: Step 1 may be performed at any time Cue:
Locate and OPEN BOP CV-9, step F.2 All prerequisites are met NOTE Provide the examinee with a copy of the BOP CV-9 The evaluator may judge the candidate, if performed on the simulator, by correctly performing the critical steps, and the candidates competency by NOT receiving the following alarms:
- 1-9-B1 LP LTDWN REL TEMP HIGH
- 1-9-A1 REGEN HX LTDWN TEMP HIGH
- 1-9-E2 LTDWN TEMP HIGH
- 1-9-D3 CHG LINE FLOW HI LOW
- 2. Adjust _CV121, in manual to compensate for additional ltdwn flow At 1PM05J:
- Place 1CV121 in Manual
- Raise charging flow to about 132 gpm using the raise pushbutton as indicated on 1FI-121A
CR JPM b.
ELEMENT SAT STANDARD UNSAT Comment Number
- 3. Place 1PCV-CV131 to manual and lower letdown pressure to ~180 psig.
At 1PM05J:
- PLACE 1CV131 in MANUAL AND
- LOWER letdown pressure to ~180 psig by raising output on 1PK-131 The examinee may decide that step 4 is NOT required and go to step 5.
NOTE
- 4. If required, ADJUST 1CC130A/B, as necessary At 1PM05J:
o Place 1TK-130 in MANUAL AND o RAISE Output
- 5. Raise letdown flow from 75 gpm to 120 gpm letdown NOTE to Evaluator: Evaluate the alarms that annunciate to determine competency of manual operations of controls in previous 3 steps At 1PM05J:
- SIMULTANEOUSLY OPEN 1CV8149A AND
- SIMULTANEOUSLY ADJUST PCV-1CV131 to maintain pressure ~370 psig
- 6. Restore 1PCV-CV131 to AUTO At 1PM05J:
- PLACE 1CV131 in AUTO If examinee manipulated 1CC130A/B in manual to control letdown temperature perform step 7. If the valve was not manipulated and temperature is normal, step 7 may be bypassed.
NOTE
CR JPM b.
ELEMENT SAT STANDARD UNSAT Comment Number
- 7. Ensure 1CC130A/B is maintaining normal letdown temperature of about120 °F.
At 1PM05J:
° Check letdown temp.
normal on 1TI-130
- Place 1TK-130 in AUTO
- 8. Adjust 1CV121, in manual to match charging and letdown flow while establishing PZR at program level At 1PM05J:
o Adjust 1CV121 in Manual o Verify charging flow is about 12 gpm greater than letdown flow and PZR level is trending to program.
- Place 1FK-121 in AUTO Cue: (if required) This JPM is completed Informs US that 120 gpm letdown flow is in service RECORD STOP TIME:
CR-b INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
Unit 1 is at 100% power, steady state, equilibrium Xenon, MOL
- 3.
Letdown flow is currently 75 gpm INITIATING CUE
- 1.
You have been directed to raise letdown flow to 120 gallons per minute and then restore systems to automatic in accordance with BOP CV-9, step 2.
- 2.
Inform the US when complete.
- 3.
Another NSO will respond to ALL other Control Room annunciators and conditions.
Exelon Nuclear Job Performance Measure Perform Transfer to Hot Leg Recirc (1SI-8840 will not OPEN)
JPM Number:
CR JPM c.
Revision Number:
00 Date:
1/24/2013 Revised By:
Bill Hochstetter Instructor Date 1/24/13 Reviewed By:
Chuck Guernsey Operations Representative Date 03/03/2013 Approved By:
Rob Lawlor Operations Representative Date 03/03/2013
CR JPM c.
INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
A large LOCA is in progress.
- 3.
1BEP-1 step 19 has been completed.
- 4.
5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 50 minutes has elapsed since SI was actuated.
- 5.
The Shift Manager is aware of this procedure transition INITIATING CUE
- 1.
The Unit Supervisor has directed you to proceed with 1BEP ES-1.4, Transfer to Hot Leg Recirculation.
CR JPM c.
RECORD START TIME:
ELEMENT SAT STANDARD UNSAT Comment Number NOTE If this JPM is performed on the simulator, only the cues underlined Once the examinee references the procedure the evaluator may hand the candidate a copy of 1BEP ES-1.4 are required to be provided to the examinee
- 1. Refer to 1BEP ES-1.4, Transfer to Hot Leg Recirculation Note: This step may be performed at any time.
LOCATE and OPEN 1BEP ES-1.4
- 2. Place SVAG Valve Bus Feeds to Close.
At 1PM06J, CLOSE:
480V Feed to Bus 131X1A/X2A 480V Feed to Bus 132X2A/X4A
- 3. Close RH to cold legs isol valves.
At 1PM06J, CLOSE:
1SI8809A 1SI8809B
- 4. Check 1A RH pump running.
At 1PM06J:
- CHECK RHR pump 1A RUNNING
- OPEN 1RH8716A Alternate Path JPM starts here NOTE
- 6. Open RH to hot legs isol valve.
At 1PM06J:
- Recognize that 1SI8840 will not OPEN
CR JPM c.
ELEMENT SAT STANDARD UNSAT Comment Number
- CLOSE 1RH8716A
- CLOSE 1RH8716B
- 8. OPEN RH to cold legs isol. valves At 1PM06J:
- OPEN 1SI8809A
- OPEN 1SI8809B
- 9. Stop SI pump 1A.
At 1PM06J:
STOP 1A SI pump
- 10. Close SI pump 1A to cold legs isol valve.
At 1PM06J:
CLOSE 1SI8821A
- 11. Open SI pump 1A to hot legs isol valve.
At 1PM06J:
OPEN 1SI8802A
- 12. Start the 1A SI pump.
At 1PM06J:
START 1A SI pump
- 13. Stop SI pump 1B.
At 1PM06J:
STOP 1B SI pump
- 14. Close SI pump 1B to cold legs isol valve.
At 1PM06J:
CLOSE 1SI8821B
- 15. Open SI pump 1B to hot legs isol valve.
At 1PM06J:
OPEN 1SI8802B
- 16. Start the 1B SI pump.
At 1PM06J:
START 1B SI pump
- 17.
Check SI pumps to hot legs isol valves open At 1PM06J, Verify OPEN 1SI8802A 1SI8802B
- 18. Close SI pumps to cold leg isol valve At 1PM06J:
CLOSE 1SI8835
CR JPM c.
ELEMENT SAT STANDARD UNSAT Comment Number
- 19. Place SVAG Valve Bus Feeds to TRIP.
At 1PM06J, TRIP 480V Feed to Bus 131X1A/X2A 480V Feed to Bus 132X2A/X4A Cue:
This JPM is completed RECORD STOP TIME:
CR-c INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
A large LOCA is in progress.
- 3.
1BEP-1 step 19 has been completed.
- 4.
5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 50 minutes has elapsed since SI was actuated.
- 5.
The Shift Manager is aware of this procedure transition INITIATING CUE 1 The Unit Supervisor has directed you to proceed with 1BEP ES-1.4, Transfer to Hot Leg Recirculation.
Exelon Nuclear Job Performance Measure Align the SX towers for LOCA conditions (Failure of OG SX tower fan to start)
JPM Number:
CR d Revision Number:
04 Date:
01 / 25 / 2013 Developed By:
W. Hochstetter Instructor Date 01/25/13 Validated By:
Greg Gugle SME or Instructor Date 03/03/2013 Approved By:
Rob Lawlor Operations Representative Date 03/03/2013
CR JPM d.
INITIAL CONDITIONS
- 1. You are the Unit 2 Assist NSO.
- 2. A LOCA is in progress with containment spray actuated
- 3. 2BEP-0 is in progress.
INITIATING CUE The Unit Supervisor directs you to align the SX towers per 2BEP-0, step 14.g.
CR JPM d.
JPM Start Time:
STEP ELEMENT SAT STANDARD UNSAT Comment Number NOTE:
If this JPM is performed on the simulator, only the underlined Once the examinee references the procedure the evaluator may hand the candidate a copy of 2BEP 0 step 14.g cues are required to be provided to the examinee.
1 Refer to 2BEP 0 o
LOCATE and OPEN 2BEP 0
- 2 Verify/open all 8 SX tower riser valves At 0PM01J VERIFY/OPEN:
o 0SX163A o
0SX163B 0SX163C 0SX163D o
0SX163E o
0SX163F o
0SX163G o
0SX163H NOTE:
If this JPM is performed in the plant, then some or all of the SX tower bypass valves may be open. Give the appropriate cues if the bypass valve is open.
The examinee may elect not to close the valve if SX pump discharge temperature is less than 52°F as the valve will immediately automatically reopen.
3 Verify/close all 4 hot water basin bypass valves At 0PM01J VERIFY/CLOSE:
o 0SX162A o
0SX162B o
0SX162C o
0SX162D
CR JPM d.
STEP ELEMENT SAT STANDARD UNSAT Comment Number NOTE:
The 0G SX tower fan will not be allowed to start in the following series of steps and therefore starts the alternate path required to accomplish the SX Tower alignment task. The examinee may attempt to start the fan a second time. If so, provide the appropriate cues.
ALTERNATE PATH STARTS HERE
- 4 Verify/start all 8 SX cooling tower fans in High Speed (wont start): If examinee expresses to the evaluator CUE: understand 0SX03CG wont start.
At 0PM01J Verify/start in High Speed:
o 0SX03CA o 0SX03CB
- 0SX03CC
- 0SX03CD o 0SX03CE o 0SX03CF
- 0SX03CG o 0SX03CH
- 5 Close riser valve for 0G SX tower fan At 0PM01J Cue: Outside air temperature is 80°F
- Close 0SX163G CUE This JPM is complete.
JPM Stop Time:
CR JPM d.
INITIAL CONDITIONS
- 1. You are the Unit 2 Assist NSO.
- 2. A LOCA is in progress with containment spray actuated.
- 3. 2BEP-0 is in progress.
INITIATING CUE The Unit Supervisor directs you to align the SX towers per 2BEP-0, step 14.g.
Exelon Nuclear Job Performance Measure Align Containment Spray for Recirculation JPM Number:
CR e Revision Number:
02 Date:
01 / 25 / 2013 Developed By:
W. Hochstetter Instructor Date 1/25/13 Validated By:
Chuck Guernsey Validator/SME Date 03/03/2013 Approved By:
Rob Lawlor Operations Representative Date 03/03/2013
CR JPM e TASK STANDARDS:
- 1.
Align 1A containment spray pump suction to the containment recirculation sump prior to the pump losing suction (RWST level < 9% or exhibiting signs of caviation).
- 2.
Determine 1CS009B will not open.
- 3.
Stop 1B containment spray pump prior to the pump losing suction (RWST level < 9% or exhibiting signs of caviation).
- 4.
Isolate both containment spray pumps from the RWST.
INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
Unit 1 has experienced a LOCA.
- 3.
1A and 1B Containment Spray pumps are running.
- 4.
RWST level is as indicated.
- 5.
1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, has been completed up to step 9.
INITIATING CUE
- 1. The Unit 1 Unit Supervisor has directed you to align 1A and 1B Containment Spray pumps per step 9 of 1BEP ES-1.3.
- 2. Inform the Unit 1 Unit Supervisor when you have completed aligning the CS pumps.
STEP ELEMENT SAT STANDARD UNSAT Comment number
- 1.
Refer to 1BEP ES-1.3, Transfer to Cold Leg Recirculation Refer to 1BEP ES-1.3, Transfer to Cold Leg Recirculation, step
- 9.
2 Determines RWST level is appropriate for CS pump suction swap to CNMT sump Perform the following at 1PM06J:
- Check RWST LEVEL LO-3 status lights lit.
NOTE:
EVALUATOR NOTE: Alternate path begins here.
- 3 Open 1CS009A & B Determine 1CS009B valve will NOT open.
Perform the following at 1PM06J:
- Determine 1CS009B will not open.
o Inform US 1CS009B will not open.
- 4 Stop 1B CS Pump Perform the following at 1PM06J:
- Determine 1B CS pump must be stopped.
Perform the following at 1PM06J:
6 Verify 1A CS pump running.
Verify 1A CS pump run light lit.
CUE This JPM is complete.
CR JPM e INITIAL CONDITIONS
- 1.
You are the Unit 1 NSO.
- 2.
Unit 1 has experienced a LOCA.
- 3.
1A and 1B Containment Spray pumps are running.
- 4.
RWST level is as indicated.
- 5.
1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, has been completed up to step 9.
INITIATING CUE
- 1.
The Unit 1 Unit Supervisor has directed you to align 1A and 1B Containment Spray pumps per step 9 of 1BEP ES-1.3.
- 2.
Inform the Unit 1 Unit Supervisor when you have completed aligning the CS pumps.
Exelon Nuclear Job Performance Measure Synchronize a SAT to a Bus being Fed by a DG JPM Number:
CR JPM f Revision Number:
09 Date:
01 / 30 / 2013 Developed By:
Bill Hochstetter Instructor Date 1/30/2013 Validated By:
Greg Gugle SME or Instructor Date 3/3/2013 Approved By:
Rob Lawlor Operations Representative Date 3/3/2013
CR JPM f INITIAL CONDITIONS
- 1. You are an extra NSO.
- 2. The unit is in MODE 1.
- 3. The 1B DG was started manually and is supplying bus 142 to support Unit 1 SAT restoration per BOP AP-52
- 4. BOP AP-52 is complete up to step F.18.f INITIATING CUE The US directs you to synchronize the SAT back to bus 142 by placing the 1B DG in parallel to the grid per BOP AP-32.
Fill in the JPM Start Time when the student acknowledges the Initiating Cue.
STEP ELEMENT SAT STANDARD UNSAT Comment Number 1
Refer to BOP AP-32 LOCATE and OPEN BOP AP-32 CUE All prerequisites are met.
2 Check method of DG start At 1 PM01J:
o Leave Mode C/S in AUTO 3
Verify the D/G is running normally At 1 PM01J:
o Check DG frequency is about 60 Hz o Check DG voltage is about 4160 volts CUE (if asked): breaker 2424 is open.
- 4 Turn synchroscope on At 1 PM01J:
Verify minimum incoming voltage At 1 PM01J:
- VERIFY DIV 12 incoming voltage >
114 VAC
- 6 Verify/Adjust DG voltage At 1 PM01J:
- ADJUST DG voltage control so running voltage is slightly higher than incoming voltage
CR JPM f STEP ELEMENT SAT STANDARD UNSAT Comment Number 7
Verify on all three phases voltages are equal At 1 PM01J:
VERIFY DG voltage meter indicates the same voltage when DG voltmeter selector switch in placed in the following positions:
- ØAB
- ØBC
- ØCA NOTE:
If the governor is adjusted in LOWER direction, the synchroscope will rotate faster in the FAST direction..
- 8 Adjust frequency At 1 PM01J:
- PLACE DG governor adjust in RAISE until DIV 12 synchroscope is rotating slowly in the SLOW direction
- 9 Close ACB 1422 At 1 PM01J:
WHEN DIV 12 synchroscope is slightly before the 12 oclock position:
- CLOSE ACB 1422 o CHECK ACB 1422 closed 10 Verify successful parallel operation At 1 PM01J:
- VERIFY synchroscope is locked in at 12 oclock position 11 Turn synchroscope off At 1 PM01J:
- For ACB 1422 PLACE synchroscope switch in OFF
CR JPM f STEP ELEMENT SAT STANDARD UNSAT Comment Number NOTE:
When Trainee has stabilized DG loading (so as to not get a reverse power trip on the output breaker) cue:
CUE This JPM is complete.
JPM Stop Time:
CR JPM f INITIAL CONDITIONS
- 1.
You are an extra NSO.
- 2.
The unit is in MODE 1.
- 3.
The 1B DG was started manually and is supplying bus 142 to support Unit 1 SAT restoration per BOP AP-52.
- 4. BOP AP-52 is complete up to step F.18.f INITIATING CUE The US directs you to synchronize the SAT back to bus 142 by placing the 1B DG in parallel to the grid per BOP AP-32.
Exelon Nuclear Job Performance Measure Change RM-11 Setpoints in Preparation for Waste Gas Decay Tank Release JPM Number:
CR JPM g Revision Number: 1 Date:
7/13/2011 Revised By:
Bill Hochstetter
- Instructor Date 7/13/11 Validated By:
Kelly Wilson
- 0 SME or Instructor Date 3/03/13 Approved By:
Rob Lawlor*
Training Department Date 03/03/13
- Signature on File
CR JPM g INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
A 0A Waste Gas Decay Tank release is pending.
- 3.
0PR02J is operable.
INITIATING CUE You have been instructed to perform Section 5.1.2 of BCP 400-TWASTE GAS in preparation for this release.
CR JPM g RECORD START TIME:
ELEMENT SAT STANDARD UNSAT Comment Number NOTE If this JPM is performed on the simulator, only the underlined cue needs to be provided to the examinee.
To initiate this JPM, hand the partially completed BCP 400-TWASTE GAS to the examinee.
- 1. Refer to the partially completed BCP 400- TWASTE GAS
° REVIEW BCP 400-TWASTE GAS for completeness up to Section 5.1.1 NOTE The candidate may elect to inform Unit 2 of the pending evolution. If that occurs respond that Unit 2 concurs with the performance of this evolution
- 2.
Functional Test of 0PA202 and 0PB102 Cue: The inplant EO reports all 0GW9298 valves (A, B, C, D, E and F) are CLOSED Cue:
Radwaste operator reports CS for 0GW014 is in the open position Cue:
- Calls EO to verify/close All 0GW9298 valves (A, B, C, D, E and F)
Radwaste operator reports 0GW014 is in the open position using the Air Controller
- Calls Rad Waste panel operator to verify C/S for 0GW014 is in open position
- Calls Rad Waste panel operator to verify 0GW014 is in open position using Air Controller
- 3. RM-11 supervisory mode At the RM-11:
PLACE RM-11 in Supervisory Mode
- 4. Select monitor At the RM-11, Grid 3, monitor 0PR02J:
SELECT the LOW Gas Channel 0PA202 and DEPRESS the SEL key
CR JPM g ELEMENT SAT STANDARD UNSAT Comment Number
- 5. Enter a new high alarm setpoint channel NOTE: The monitor should be reading 7.9E-06. and should be set to a lower value to test the interlock.
Example: 8.33 E-07 At the RM-11:
DEPRESS Channel Item key Select chan. Item 9 (KEY IN 9)
Depress SEL key ENTER a new High Alarm setpoint (below current value of 7.9E-06)
DEPRESS the Enter key
- 6. Verifies Auto Operation
- Verify 0GW014 CLOSED automatically Cue:
The Radwaste operator reports 0GW014 CLOSED automatically Cue:
Radwaste operator reports Alarm 0GW02J A-9 is LIT Cue: Radwaste operator reports C/S for 0GW014 is in the closed position Cue:
Calls Rad Waste panel operator to verify 0GW014 has CLOSED automatically Radwaste operator reports controller demand for 0GW014 is at 0.
Calls Rad Waste panel operator to verify Gas Decay Tank Vent Stack Eff Rad Hi Alarm comes in at 0GW02J A-9 Calls Rad Waste panel operator to place C/S for 0GW014 in the CLOSED position Calls Rad Waste panel operator to reduce controller demand to 0 at 0GW02J
CR JPM g ELEMENT SAT STANDARD UNSAT Comment Number
- 7. High alarm setpoint for 0PA202 Selects 8.33E-03 At the RM-11:
- SELECT 0PA202
- DEPRESS Channel Items key Select chan. Item 9 (KEY IN 9 )
- Depress SEL key ENTER a new High Alarm setpoint DEPRESS the Enter key Verify new value is displayed
- 8.
Initial form as NSO Initial form
- 9.
Requests verification Cue:
The US will continue at step
- 12.
Examinee requests verification This JPM is completed RECORD STOP TIME:
CR JPM g INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
A 0A Waste Gas Decay Tank release is pending.
- 3.
0PR02J is operable.
INITIATING CUE You have been instructed to perform Section 5.1.2 of BCP 400-TWASTE GAS in preparation for this release.
Exelon Nuclear Job Performance Measure Prepare U1 for RSP Operations JPM Number:
CR-h Revision Number: 3 Date:
2/6/2013 Revised By:
Bill Hochstetter Instructor Date 2/06/13 Validated By:
Greg Gugle Ops Dept.
Date 03/03/2013 Approved By:
Rob Lawlor /s/
Ops Department Date 03/03/2013
CR JPM h.
INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
The Unit has been manually tripped per 1BOA PRI-5.
- 3.
0BOA PRI-5 and 1BOA PRI-5 have been entered due to a fire.
- 4.
1BOA PRI-5 step 6.d. is being carried out by another NSO.
INITIATING CUE
- 1.
The US has directed you to prepare Unit 1 for Remote Shutdown Panel operations per 1BOA PRI-5, step 6.
- 2.
Inform the US when complete.
CR JPM h.
RECORD START TIME:
ELEMENT SAT STANDARD UNSAT Comment Number
- 1. Refer to 1BOA PRI-5, Control Room Inaccessibility Note: Step 1 may be performed at any time (step 6)
° LOCATE and OPEN 1BOA PRI-5 NOTE If this JPM is performed on the simulator, only the cues underlined are required to be provided to the examinee.
Provide the examinee with a copy of 1BOA PRI-5, step 6.
- 2. Verify letdown divert valve in AUTO.
At 1PM05J:
° Verify 1CV112A is in AUTO
- 3. Place PZR pressure control to channels 457/458.
At 1PM05J:
Place PZR Press Control Selector to 457/458
- 4. Place PZR level control to channels 460/461.
At 1PM05J:
Place PZR Level Control Selector to 460/461
- 5. Obtain logs and keys.
Cue: (If asked)
Obtain the following:
step 6.d is being performed by another NSO Unit Log Book Unit 1 PRI-5 keys Temporary Change Tracking Log Equipment Status Tag Log/Abnormal Component Position Sheet Book
CR JPM h.
ELEMENT SAT STANDARD UNSAT Comment Number
- 6. Open RCS loop sample valves.
At 1PM11J OPEN:
1PS9356A 1PS9356B
- 7. Open PZR liquid sample valves.
At 1PM11J OPEN:
1PS9355A 1PS9355B
- 8. Open PZR steam sample valves.
At 1PM11J OPEN:
1PS9354A 1PS9354B Cue: (if required)
Informs US of completion This JPM is completed RECORD STOP TIME:
CR JPM h.
INITIAL CONDITIONS
- 1.
You are the Unit 1 Assist NSO.
- 2.
The Unit has been manually tripped per 1BOA PRI-5.
- 3.
0BOA PRI-5 and 1BOA PRI-5 have been entered due to a fire.
- 4.
1BOA PRI-5 step 6.d. is being carried out by another NSO.
INITIATING CUE
- 1.
The US has directed you to prepare Unit 1 for Remote Shutdown Panel operations per 1BOA PRI-5, step 6.
- 2.
Inform the US when complete.