ML13064A408

From kanterella
Jump to navigation Jump to search
Submittal of 2012 Annual Radioactive Effluent Release Report
ML13064A408
Person / Time
Site: Saint Lucie  
Issue date: 02/28/2013
From: Katzman E
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2013-078
Download: ML13064A408 (62)


Text

February 28, 2013 L-2013-078 10 CFR 50.36 10 CFR 50.36a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 2012 Annual Radioactive Effluent Release Report Pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.7, enclosed is the 2012 Annual Radioactive Effluent Release Report for St. Lucie Units I and 2. The report provides information for the 12-month period beginning January 1, 2012 and ending December 31, 2012. includes the Combined Annual Radioactive Effluent Release Report. is a copy of C-200, Offsite Dose Calculation Manual (ODCM), Revision 38. is a copy of the marked up pages from Revisions 36, 37 and 38 of the ODCM.

Please contact us with any questions regarding this submittal.

Since ely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/tIt Enclosures

4ooc, Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 TABLE OF CONTENTS 1.0 PROGRAM DESCRIPTION 2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges 2.2 Non-Routine Planned Discharges 2.3 Radioactive Waste Treatment System Changes 2.4 Annual Land Use Census Changes 2.5 Effluent Monitoring System Inoperability 2.6 Offsite Dose Calculation Manual Changes 2.7 Process Control Program Changes 2.8 Corrections to Previous Reports 2.9 Other 2.10 Groundwater Protection Program 3.0 TABLES (ENCLOSURE 1) 3.1 Gaseous Effluents & Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 1.0 PROGRAM DESCRIPTION Regulatory Limits The ODCM Radiological Effluent Control limits applicable to the release of radioactive material in liquid and gaseous effluents are described in the following sections.

Fission and Activation Gases (Noble Gases)

The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary shall be limited to less than or equal to 500 mrems/yr to the whole body and less than or equal to 3000 mrems/yr to the skin. The air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the site boundary shall be limited to the following:

a. During any calendar quarter: Less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation, and
b. During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.

Iodine-131, Iodine-133, Tritium, Carbon-14 and Radioactive Material in Particulate Form The dose rate due to iodine-131, iodine-133, tritium and all radionuclides in particulate form with half lives greater than 8 days, released in gaseous effluents from the site to areas at and beyond the site boundary, shall be limited to less than or equal to 1500 mrem/yr to any organ.

The dose to a MEMBER OF THE PUBLIC from iodine-131, iodine-133, tritium, carbon-14 and all radionuclides in particulate form with half lives greater than 8 days, in gaseous effluents released, from each unit, to areas at and beyond the site boundary, shall be limited to the following:

a. During any calendar quarter: Less than or equal to 7.5 mrems to any organ, and
b. During any calendar year: Less than or equal to 15 mrems to any organ.

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 Liquid Effluents The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to 10 times the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.OE-4 pCi/ml total activity.

The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to unrestricted areas shall be limited:

a. During any calendar quarter to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and
b. During any calendar year to less than or equal to 3 mrems to the whole body and to less than or equal to 10 mrems to any organ.

Total Dose The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.

Effluent Concentration Limits Gaseous Effluents For gaseous effluents, effluent concentration limits (ECL) values are not directly used in release rate calculations since the applicable limits are expressed in terms of dose rate at the site boundary.

Liquid Effluents The values specified in 10 CFR Part 20, Appendix B, Table 2, Column 2 are used as the ECL for liquid radioactive effluents released to unrestricted areas. A value of 2.OE-04 pCi/ml is used as the ECL for dissolved and entrained noble gases in liquid effluents.

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 Measurements and Approximations of Total Radioactivity Measurements of total radioactivity in liquid and gaseous radioactive effluents were accomplished in accordance with the sampling and analysis requirements of Tables 4.11-1 and 4.11-2, respectively, of the St. Lucie ODCM. Estimates of errors are in accordance with Methodology Section 4.4, of the ODCM.

The estimate of errors associated with values reported is as follows:

LIQUID GASEOUS Error Topic Avg. % Max. %

Avg. % Max. %

Release Point Mixing 2

5 NA NA Sampling 1

5 2

5 Sample Preparation 1

5 1

5 Sample Analysis 3

10 3

10 Release Volume 2

5 4

15 Total %

9 30 10 35 (above values are examples only)

The predictability of error for radioactive releases can only be applied to nuclides that is predominant in sample spectrums. Nuclides that are near background relative to the predominant nuclides in a given sample could easily have errors greater than the above listed maximums.

Liquid Radioactive Effluents Each batch release was sampled and analyzed for gamma emitting radionuclides using gamma spectroscopy, prior to release. Composite samples were analyzed monthly for tritium and gross alpha radioactivity in the onsite laboratory using liquid scintillation and air ion chamber counting techniques, respectively. Composite samples were analyzed quarterly for Sr-89, Sr-90, Fe-55, Ni-63 and C-14 by a contract laboratory.

The results of the composite analyses from the previous month or quarter were used to estimate the quantities of these radionuclides in liquid effluents during the current month or quarter. The total radioactivity in liquid effluent releases was determined from the measured and estimated concentrations of each radionuclide present and the total volume of the effluent released during periods of discharge.

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS I AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 Gaseous Radioactive Effluents Each gaseous batch, the release was sampled and analyzed for radioactivity prior to release. For releases from Gas Decay Tanks, noble gas grab samples were analyzed for gamma emitting radionuclides using gamma spectroscopy. For releases from the Containment Buildings, samples were taken of noble gas and tritium grab samples, and analyzed for gamma emitting radionuclides prior to each release. The results of the analyses and the total volume of effluent released were used to determine the total amount of radioactivity released in the batch mode.

For continuous effluent release pathways, noble gas and tritium grab samples were collected and analyzed weekly for gamma emitting radionuclides by gamma spectroscopy and liquid scintillation counting techniques, respectively. Continuous release pathways were continuously sampled using radioiodine adsorbers and particulate filters. The radioiodine adsorbers and particulate filters were analyzed weekly for gamma emitting radionuclides using gamma spectroscopy. Results of the noble gas and tritium grab samples, radioiodine adsorber and particulate filter analyses from the current week and the average effluent flow rate for the previous week were used to determine the total amount of radioactivity released in the continuous mode. Monthly composites of particulate filters were analyzed for gross alpha activity, in the onsite laboratory using the air ion chamber counting technique. Quarterly composites of particulate filters were analyzed for Sr-89 and Sr-90 by a contract laboratory.

Meteorological Monitoring Program In accordance with ODCM Administrative Control 3.11.2.6.b., a summary of hourly meteorological data, collected during 2012, is retained onsite.

This data is available for review by the NRC upon request. During 2012, the goal of >90% joint data recovery was met. Actual meteorological collected during the year was used in the offsite dose calculations in this report.

Carbon-14 Dose Estimation The estimate of carbon-14 (C-14) released from the St. Lucie Nuclear Plant was derived from the EPRI document, "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents," Report 1021106, issued December 2010.

The site specific source term values used in the St. Lucie calculations were taken from Section 4-28 of the report, and employed the proxy generation rate values for a Combustion Engineering reactor. The actual 2012 operating data for the units was employed for the calculations to derive the total curies released for each unit.

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 Carbon-14 Dose Estimation (continued)

The total amount of C-14 released in 2012 for Unit 1 was 6.68 Ci, and the total amount of C-14 released in 2012 for Unit 2 was 7.53 Ci. The highest calculated dose is found to be "Bone Dose" to a "Child" through "Inhalation". The total combined dose from C-14 through this pathway is 1.OIE-01 mrem/yr.

Additionally, a "Child" consuming vegetables from the garden located at 2.0 miles in the WSW direction from the plant would have received a total combined "Bone Dose", including C-14, of 1.01E-1 mrem/yr.

Using the same release values, the dose to a visitor on site (Adult Lifeguard) is found to be 4.35E-01 mrem/yr, Total Body dose.

All C-14 dose calculations are based on Regulatory Guide 1.109 values.

This is a fraction of the I mrem annual whole body dose received to the average US citizen from natural occurring Carbon-14, primarily generated through cosmogenesis in the terrestrial biosphere (Reference National Council of Radiation Protection Report 45, Natural Background Radiation in the United States).

2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges There were two abnormal (unplanned) releases or discharges from the site during the report period. Both releases were due to leaks associated with the gas analyzer in the Unit 1 Waste Gas Decay Tank system. In both cases, the equipment deficiencies were corrected and the gas analyzer was returned to service. Both of the unplanned releases were monitored by the Plant Vent Monitor that is installed on the Plant Vent Stack. Neither release challenged or exceeded site release or dose limits. Both releases are included in the gaseous portion of the tables, and are included in the site's dose calculations for the year.

2.2 Non-Routine Planned Discharges No non-routine planned discharges were made during the report period.

2.3 Radioactive Waste Treatment System Changes No changes wer'e made to the waste treatment system during the report period.

2.4 Annual Land Use Census Changes There were no changes to the Land Use Census during 2012.

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 2.5 Effluent Monitoring System Inoperability There were no effluent monitors out of service for greater than 30 days.

2.6 Offsite Dose Calculation Manual Changes Three revisions were made to the St. Lucie ODCM during the report period. The first revision was to change a procedure reference number to the new number used by the site. The second revision was to change the stated thermal megawatt output for Unit I after the power up-rate project.

The third revision was to change the stated thermal megawatt output for Unit 2 after its power up-rate project.

2.7 Process Control Program Changes There were no changes to the Process Control Program during the report period.

2.8 Corrections to Previous Reports None 2.9 Other Ten batch releases were made from the South Settling Basin to the Intake Canal during the year to lower the water level due to approaching severe weather. All ten releases were analyzed according to the ODCM and site procedural requirements and were found to have no alpha, gamma, tritium or hard to detect isotopes. The releases are listed below:

Release start date Volume of release May 17 5.97E6 gallons June 1 1.05E7 gallons June 12 1.05E7 gallons June 25 1.07E7 gallons August 22 1.94E7 gallons September 15 4.60E6 gallons September 22 6.97E6 gallons October 19 5.26E6 gallons November 13 2.92E6 gallons December 12 3.19E5 gallons A modification was made in the fourth quarter of 2012 to the discharge point for the South Settling Basin. A manual valve and flow measuring device were installed to more accurately control and account for the discharges from this pathway. The last discharge of the year was made to perform post maintenance testing of the new system to ensure satisfactory operation of the newly installed components.

FLORIDA POWER LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012

[]

2.10 Groundwater Protection Program H3 Feb H3 Mar H3 Apr H3 May H3 June H3 July H3 Aug H3 Sept H3 Oct H3 Nov H3 Dec SentinelWellID H3Jan2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 Diesel - Unit I & 2 pCi/I pCi/I pp ill pCi/I pCi/I pCi

/I pCi/I pCilI pCi/l pCi/I pCi/I MW-3 552 359 385 794 MW-4 996 2930 13400 7920 1980.

499 426 497/594.

532 486 532 M W -5

<M D C

<M D C

<M D C

<M D C

<M D C.....

MW-6 904 825 752 1040 876 1300 1040 1000 978 789 1150 1410 MW-7 274

<MDC 235 357 271 MW-15 313 349 364 306 1660 MW-16 253

<MDC 231 1020 486 MW-17 451 320 374 432 689 832 1400 2310 496 3570 3000 1510 MW-18D 955 955 753 881 718 807 882 1450 1520 1280 1470 1370 MW-19 308

<MDC

<MDC

<MDC MW-22D 200 190

<MDC 386 262 MW-26

<MDC

<MDC

<MDC

<MDC RW-2 1550 1890 3440 5580 3890 2520 1220 911 584.

478 418...

558 RW-4 273

<MDC

<MDC

<MDC

<MDC

<MDC 187

<MDC

<MDC RW-5

<MDC

<MDC 227

<MDC MW-30

<MDC 327 289 300 MW-31 418 478 499 501 347 MW-32 526 372 361 468 MW-33 1360 1190 1630.....

9-3-7 732 1100.. 11,90 1420 1020 1000 1240.... 1010 H3Feb H3Mar H3Apr H3May H3June H3July H3Aug H3Sept H3 Oct H3 Nov H3 Dec MonitorWellID H3Jan2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 TLO Wells pCi/l pCi/l pCi/l pCi/l pCill pCi/l pCill pCi/I pCi/l pCi/l pCi/l pCi/l Unit 1 - MWO01 290 221 192 509 336 408 687 274 519 2090 1330 906 Unit 1 - MWO02 506 584

<MDC 299 421 453 364 465 217

<MDC 215

<MDC Unit 1 - MWO03 212 271 285 490 201 Unit 1 - MWO04 663 593 329 472 Unit 1-MWO05 809 691 571 519 462 1940 692 769 1280 433 610 693 Unit 2 - MWO01 493 1780 852 1260 3080 3090 1740 657 65 251

<MDC

<MDC Unit 2 - MW002 687 763 642 1390 1300 1040 501 254

<MDC

<MDC

<MDC

<MDC Unit 2 - MWO03 849 1080 732 801 403 692 595 653 423 592 518 688 Unit 2-MWO04 1020 1140 1010 1150 1070 1190 1230 904

FLORIDA POWER LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 F]

2.10 Groundwater Protection Program H3Feb H3Mar H3Apr H3May H3June H3July H3Aug H3Sept H3 Oct H3 Nov H3 Dec 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 Mixed Plume pCiIl pCi/I pCill pCi/I pCi/I pCiIl pCi/I pCiIl pCi/I pCi/I pCiIl pCiIl (S)-MW-1

<MDC

<MDC

<MDC

<MDC (S)-MW-2 Inactive Well (S)-MW-3 Inactive Well (S)-MW-4 1

6851 1

7851 5511 1

5121 1

3821 (S)-MW-5 Inactive Well (S)-MW-6 3021 1

3051 1

1 4331 3661 (S)-MW-7A

<MDCI

<MDCI

<MDCI (S)-MW-10 Inactive Well (S)-MW-i 1I 5671 1

1 4251 5

1 5731 1

4751 (S)-MW-1 3D Inactive Well (S)-MW-14 Inactive Well (S)-MW-1 5D

<MDC

<MDC 324 197 (S)-MW-16

<MDC

<MDC

<MDC

<MDC (S)-MW-16i 301

<MDC

<MDC

<MDC (S)-MW-17 164

<MDC 260

<MDC

<MDC

<MDC (S)-MW-18

<MDC

<MDC

<MDC

<MDC (S)-MW-19 I <MDC 2991

<MDC

<MDC H3Feb H3Mar H3Apr H3May H3June H3July H3Aug H3Sept H30ct H3 Nov H3 De 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 2012 Neutralization Basin pCi/I pCi/I pCill pCi/I pCi/I i

p2i/

pCi/I pCill pCi/I p

pCi/I pCill PSLED - 2

<MDC

<MDC NB-MW-1

<MDC

<MDC NB-MW-2

<MDC

<MDC

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 3.0 TABLES (ENCLOSURE 1) 3.1 Gaseous Effluents & Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS I AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 L-2013-078 ENCLOSURE I COMBINED ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (50 PAGES) 3.0 TABLES 3.1 Gaseous Effluents & Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose

FJ11ue~,t NI fla4~tm~~tit ~0ft~ure Tuesday, February 19, 2013 8:15:28AM Florida Power & Light St. Lucfe Power Plant Reg. Guide 1.21, Table 5A and 5B - Liquid and Gas Batch Release Summary A. Uquid Batch Release Totals

1. Number of Batch Releases
2. Total duration of batch releases
3. Maximum batch release duration
4. Average batch release duration
5. Minimum batch release duration B. Gas Batch Release Totals
1. Number of Batch Releases
2. Total duration of batch releases
3. Maximum batch release duration
4. Average batch release duration
5. Minimum batch release duration Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Units 1st Quarter 2nd Quarter 3rd Quarter 13 27 33 min 7.54E+03 5.73E+04 3.35E+04 min 7.43E+02 1.63E+04 1.01E+04 min 5.80E+02 2.12E+03 1.02E+03 min 3.59E+02 2.02E+02 3.12E+02 Units 1st Quarter 2nd Quarter 3rd Quarter 35 53 46 min 6.51E+03 1.64E+04 1.66E+04 min 1.21E+03 1.44E+03 2.97E+03 min 1.86E+02 3.10E+02 3.60E+02 min 2.80E+01 3.10E+01 1.80E+01 4th Quarter 17 2.49E+04 1.47E+04 1.46E+03 4.85E+02 4th Quarter 51 1.10E+04 5.69E+02 2.15E+02 1.20E+01 Year Totals 90 1.23E+05 1.63E+04 1.37E+03 2.02E+02 Year Totals 185 5.05E+04 2.97E+03 2.73E+02 1.20E+01 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

.A C' Monday, Feb

!i.'..I'I.u, u-

-g* Efuent NMiagretmet Shvare Reg. Guide 1.21, Table 6A and 68 - Liquid and Gas Abnormal Release Summary Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th QL

1. Number of Abnormal Releases 0

0 0

0

2. Total Activity of abnormal releases Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qu
1. Number of Abnormal Releases 0

1 1

0

2. Total Activity of abnormal releases Ci 0.OOE+00 1.82E-02 1.32E-02 0.00E rmary 18, 2013 2:17:34PM Florida Power & Light St. Lucie Power Plant iarter

+00 larter

+00 Year Totals 0

0.OOE+00 Year Totals 2

3.14E-02 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

EMSI Monday, February 18, 2013 2:24:17PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qu rses 0

0 0

0 releases Ci 0.OOE+00 0.00E+00 0.00E+00 0.00E-A. Liquid Abnormal Relea,

1. Number of Abnormal Rele.
2. Total Activity of abnormal arter

+00 Year Totals 0

O.OOE+00 Year Totals 2

3.14E-02 B. Gas Abnormal Release Totals

1. Number of Abnormal Releases
2. Total Activity of abnormal releases Units 1st Quarter 2nd Quarter 3rd Quarter 0

0.OOE+00 1

1.82E-02 1

1.32E-02 4th Quarter 0

0.OOE+00 Ci User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

E

~MondayFeb Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qu

1. Number of Abnormal Releases 0

0 0

0

2. Total Activity of abnormal releases Ci 0.00E+00 0.OOE+00 0.OOE+00 0.OOE B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qu
1. Number of Abnormal Releases 0

0 0

0

2. Total Activity of abnormal releases Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.00E-ruary 18, 2013 2:27:52PM Florida Power & Light St. Lucie Power Plant arter

+00 arter

+00 Year Totals 0

0.OOE+00 Year Totals 0

0.00E+00 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

AI2 Page I of 1 I,,1 /I*,)

Monday, February 18, 2013 2:15:04PM A.

fflut, M*.1ugernwit 9*£mare Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Gases

1. Total Release Ci 5.20E-01 3.03E+00 3.86E+00 6.53E-01 8.06E+00

.2. Average Release Rate for Period uCi/s 6.62E-02 3.85E-01 4.86E-01 8.21E-02 2.55E-01

3. Percent of Limit B. lodines and Halogens
1. Total Release Ci O.00E+O0 0.OOE+00 3.68E-07 3.13E-07 6.81E-07
2. Average Release Rate for Period uCi/s O.OOE+00 0.OOE+00 4.63E-08 3.94E-08 2.15E-08
3. Percent of Limit C. Particulates

.1. Total Release Ci 2.62E-07 9.03E-06 1.31E-05 0.OOE+00 2.24E-05

2. Average Release Rate for Period uCl/s 3.34E-08 1.15E-06 1.65E-06 0.OOE+00 7.08E-07
3. Percent of Limit D. Tritium
1. Total Release Ci 1.25E+01 3.67E+00 3.98E+01 2.23E+01 7.83E+01
2. Average Release Rate for Period uCi/s 1.59E+00 4.67E-01 5.01E+00 2.81E+00 2.48E+00
3. Percent of Limit E. Gross Alpha
1. Total Release Ci 4.71E-08 1.16E-07 7.20E-08 5.11E-08 2.86E-07 F. Carbon-14
1. Total Release Ci 3.19E+00 4.91E+00 3.63E+00 2.48E+00 1.42E+01
2. Average Release Rate for Period uCi/s 4.06E-01 6.25E-01 4.56E-01 3.12E-01 4.50E-01
3. Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

5, EflihteLnt fv aLit~I~t Softarr Page 1 of 4 Monday, February 18, 2013 2:15:23PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Kr-88 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period B. lodines and Halogens 1-131 Ci Ci Ci Ci Ci Ci 0.OOE+00 O.OOE-i00 0.OOE+00 0.OOE+00 2.52E-01 2.S2E-01 2.01E-01 0.OOE+0Q 2.33E-01

1. 14E+00 5.09E-02 1.63E+00 1.33E+i00 1.25E+00 0.OOE+00 0.0OE+00 0.OOE+00 2.58E+00 0.OOE+00 O.OOE+00 0.OOE+00 1.23E-01 0.OOE+00 1.23E-01 Annual 1.53E+00 1.25E+00 2.33E-01 1.26E+00 3.03E-01 4.58E+00 Ci 0.OOE+00 0.OOE+00 3.68E-07 3.13E-07 6.81E-07 C. Particulates Co-60 Cs-137 Ce-144 Total For Period D. Tritium H-3 E. Gross Alpha G-Alpha Ci Ci Ci Ci 0.OOE+00 2.62E-07 0.OOE+00 2.62E-07 1.66E-06 6.41E-06 9.65E-07 9.03E-06 6.08E-06 6.60E-06 4.10E-07 1.31E-05 0.OOE+0O 0.OOE÷OO 0.OOE+00 O.OOE+OO 7.74E-06 1.33E-05 1.38E-06 2.24E-05 Ci Ci 1.24E+01 4.71E-08 3.55E+00
1. 16E-07 3.93E+01 7.20E-08 2.22E+01 5.11E-08 7.74E+01 2.86E-07 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:15 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Page 2 of 4 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released F. Carbon-14 C-14 Ci 3.19E+00 4.91E+00 3.63E+00 2.48E+00 1.42E+01 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:15 Page 3 of 4 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total For Period B. lodines and Halogens No Nuclides Found C. Particulates No Nuclides Found Ci Ci Ci Ci Ci Ci Ca Ci Ci Ci Ci Cl Ci Ci 2.OOE-01 0.OOE+00 O.OOE+00 1.72E-04 0.OOE+00 0.OOE+00 4.75E-05 6.22E-04 4.COE-02 0.OOE+00 1.50E-04 2.77E-02 0.OOE+00 2.69E-OIL 1.26E+00 0.OOE+00 0.OOE+00 1.56E-04 0.OOE+00 2.94E-02 5.01E-05 5.28E-04 1.06E-01 2.26E-04 1.88E-03 O.OOE+0O 5.81IE-04 1.40E+00 5.97E-01 1,.79E-04 O.OOE+O0 0.OOE+O0

1. 15E-04 3.92E-01 3.61E-05 1.94E-03

.2.04E-01 1.38E-03 4.61E-03 8.46E-02 1.59E-04 1.29Ei-00 3.75E-01 O.OOE+00 1.06E-04 O.OOE+O0 6.64E-04 1.89E-02 1.13E-03 9.93E-04 1.07E-01 0.OOE+OO 3.60E-03 2.17E-02 3.93E-04 5.30E-01 Annual 2.43E+00 1.79E-04 1.06E-04 3.28E-04 7.78E-04 4.4AE-01 1.26E-03 4.08E-03 4.57E-01 1.61E-03 1.02E-02 1.34E-01 1.13E-03 3.48E+00 Ci Ci Ci 0.OOE+00 0.OOE+0O 5.64E-02 0.OOE+Q0 O.OOE+00 1.28E-01 0.OOE+00 0.OOE+00 5.65E-01 0.OOE+00 0.OOE+00 1.62E-01 0.OOE+00 O.OOE-i0O 9.12E-01 D. Tritium H-3 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: At Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:15 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Page 4 of 4 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found Ci Ci 0.OOE+00 0.OOE+GO 0.OOE+00 0.COE+O0 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+0O 0.OaE+o0 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

1/4 >EMS L~flur~c I uLL~u1eIIt 4~,ftv~ u-e Page 1 of 1 Monday, February 18, 2013 2:22:34PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table IA, Gaseous Effluents - Summation of All Releases Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. lodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit C. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ci uCi/s Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s 6.70E-04 8.53E-05 0.OOE+OO O.OOE+00 0.0OE+00 0.OOE+00 4.62E+i00 5.88E-01 2.56E-08 O.GOE+OO 0.OOE+00 1.51E+00 1.93E-01 0.00E+00 O.OOE+00 6.47E-06 8.23E-07 1.36E+00 1.74E-01 3.27E-08 1.72E+00 2.19E-01 1.35E+I00 1.70E-01 0.OOE+00 0.OOE+O0 1.27E-05 1.60E-06 2.61E+01 3.29E+00 2.40E-08 2.48E+00 3.12E-01 4-59E-01 5.77E-02 0.OOE+00 0.OOE+0O 0.QOE+0O 0.OOE+00 1.86E+01 2.34E+00 2.01E-08 2.48E+i00
3. 12E-01 Annual Uncertainty 3.32E+00 1.05E-01 O.OOE+0O O.OOE+0O 1.91E-05 6.06E-07 5.07E+01 1.60E+00 1.03E-07 6.69E+00 2.11E-01 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

D~wnEMugS mr Page I of 3 Monday, February 18, 2013 2:22:51PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Kr-88 Xe-133m Xe-133 Total For Period Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+OO 0.OOE+C0 2.33E-01

1. 14E+i00 1-38E+00 5.48E-01 0.OOE+00 0.OQE+00 5.48E-01 0.OOE+00 O.OOE+00 0.OOE+0O O.OOE+OO Annual 5.48E-01 2.33E-01 1.14E+00 1.92E+00 B. lodines and Halogens No Nuclides Found C. Particulates Co-60 Cs-137 Total For Period Ci 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 Ci Ci Ci 0.OOE+00 0.OOE+OO O.OOE+OO 1.66E-06 4.81E-06 6.47E-06 6.08E-06 6.60E-06 1.27E-05 0.OOE+00 0.OOE+00 O.OOE+OO 7.74E-06
1. 14E-05 1.91E-05
b. Tritium H-3 E. Gross Alpha G-Alpha Ci Ci Ci 4.61E+00 2.56E -08 O.3OE+00 1.34E+00 3.27E-08 1.72E+00 2.60E+01 2.40E-08 2.48E+00 1.85E+01 2.011E-08 2.48E+00 5.04E+01 1.03E-07 6.69E+00 F. Carbon-14 C-14 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:22 Page 2 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-85m Kr-85 Kr-88 Kr-89 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 O.OOE-i-O 0.Q0E+00 0.OOE-i00 0.OOE+00 4.75E-05 0.OOE+O0 5.59E-04 0.OOE+00 6.44E-05 O.OOE+00 0.OOE+O0 6.70E-04 1.23E-01 0.OOE÷00 0.OOE+0O 0.OOE-i-O 0.OQE+OO 5.O1E-05 5.28E-04 1.33E-02 2.26E-04 1.46E-03 0.OOE+00 0.OOE+00 1.39E-01.

3.12E-01 1.79E-04 0.OOE+OO 1.15E-04 3.92E-01 3.61E-05 1.94E-03 7.40E-02 1.38E-03 4.61E-03 1.35E-02 1.59E-04 8.0OE-01 3.23E-01 0.OOE+00 1.06E-04 6.64E-04 1.89E-02 1.13E-03 9.93E-04 8.92E-02 0.OOE+00 3.27E-03

2. 17E-02 1.11E-05 4.59E-01 Annual 7.58E-01 1.79E-04 1.06E-04 7.78E-04 4.11E-01 1.26E-03 3.46E-03 1.77E-01 1.61E-03 9.40E-03 3.52E-02 1.70E-04 1.40E+00 B. lodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium Ci Ci Ci Ci 0.OOE+OO 0.OOE+OO 5.69E-03 0.OOE+O0 0.OOE+00 O.OOE--00 2.76E-02 0.OOE+O0 0.OOE+00 0.OOE-e-O 1.60E-01 0.OOE+00 O.OOE+O0 0.OOE+00 1.52E-01 O.OOE+00 O.OOE+0O O.OQE-4-O 3.46E-01 O.OOE+00 H-3 E. Gross Alpha No Nuclides Found If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:22 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Page 3 of 3 Nuclides Released F. Carbon-14 No Nuclides Found Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci O.OOE+O0 O.OOE+0O O.OOE+O0 O.OOE+O0 O.OOE+O0 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

,-1 Page 1 of 1

,..Monday, February 18, 2013 2:25:35PM ift

,t SFlorida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit:

Starting: 1-Jan-2012 PSL2 Ending: 31-Dec-2012 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. Iodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit C. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit Ci uCi/s uCi/s Ci uCi/s Ci uCi/s

%C Ci uCi/s Ci uci/s 5 '20E-01 6.61E-02 O.OOE+00 a.OOE+0O 2.62E-07 3.34E-08 7.85E+00 9.98E-01

2. 15E-08 3.19E+00 4.06E-01 1.51E+00 1.92E-01 0.OOE+00 0.OOE+00 2.56E-06 3.26E-07 2.31E+00 2.94E-01 8.35E-08 3.19E+00 4.06E-01 2.51E+00 3.16E-01 3.68E-07 4.63E-08 4.1OE-07 5.16E-08 1.37E+01 1.72E+00 4.80E-08 1.14E+00 1.44E-01 1.94E-01 2.44E-02
3. 13E-07 3.94E-08 O.OOE+0Q 0.OOE+O0 3.71E+00 4.67E-01 3.09E-08 0.OOE+O0 0.OOE+00 4.74E+00 1.50E-01 6.81E-07
2. 15E-08 3.23E-06 1.02E-07 2.75E+01 8.71E-01 1.84E-07 7.53E+00 2.38E-01 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

EMS It Fillint M w~rtient~Sohwmr Page 1 of 2 Monday, February 18, 2013 2:25:50PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit:

Starting: 1-Jan-2012 PSL2 Ending: 31-Dec-2012 Continuous Mode Nuclides Released A. Fission and Activation Gases Kr-88 Xe-131m Xe-133 Xe-135 Total For Period B. lodines and Halogens 1-131 C. Particulates Cs-137 Ce-144

.Total For Period D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 C-14 Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 O.OOE+00 O.00E+0O 2.52E-01 2.5212-01 O.00E--00 2.62E-07 0.OOE+OO 2.62E-07 7.80E+00 2.15E-08 3.19E+00 2.01E-01 0.OOE+O0 O.OOE+O0 5.09E-02 2.51E-01 0.OOE+00 1.60E-06 9.65E-07 2.56E-06 2.21E+00 8.35E-08 3.19E+00 7.81E-01 1.25E+00 O.OOE+0Q O.OOE+00 2.03E+00 3.68E-07 O.OOE+O0

4. 10E-07
4. 10E-07 1.33E+01 4.80E-08 1.14E+00 O.OOE+O0 0.OOE+00 1.23E-01 0.OOE+00 1.23E-01 3.13 E-07 O.OOE+OO O.OOE+OO O.OOE+OO 3.70E+00 3.09E-08 0.OOE+00 9.82E-01 1.25E+00 1.23E-01 3.03E-01 2.65E+00 6.81E-07 1.86E-06 1.38E-06 3.23E-06 2.70E+01 1.84E-07 7.53E+00 Ci If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:25 Page 2 of 2 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-87 Kr-89 Xe-133m Xe-133 Xe-135 Xe-137 Xe-138 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci 2.OOE-01 1.72E-04 0.OOE+OO 6.22E-04 3.95E-02 8.58E-05 2.77E-02 O.OOE+00 2.68E-01 1.14E+00 1.56E-04 2.94E-02 O.OOE+O0 9.29E-02 4.27E-04 0.OOE+0O 5.81E-04 1.26E+00 2.85E-01 0.OOE+00 0.OOE+00 O.OOE+0O 1.30E-01 O.OOE+00 7.11E-02 0.OOE+OO 4.86 E-0 1 5.24E-02 O.OOE+00 0.GOE+00 O.OOE+OO 1.81E-02 3.29E-04 0.OOE+00 3.82E-04 7.12E-02 Annual 1.67E+00 3.28E-04 2.94E-02 6.22E-04 2.80E-01 8.41E-04 9.87E-02 9.63E-04 2.09E+00 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha No Nuclides Found Ci Ci Ci Ci Ci 0.OOE+0O 0.OOE+00 5.07E-02 0.OOE+00 0.OOE+O0 0.OOE+OO O.COE+00 1.O1E-01 0.OOE+00 O.OOE+O0 O.OOE+O0 0.aaE+o0 4.05E-01 O.OOE+0O 0.OOE+00 0.OOE+00 0.OOE+00 9.85E-03 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 5.66E-01 O.OOE+O0 0.OOE+0O F. Carbon-14 No Nuclides Found If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

EMS Page I of 1 Monday, February 18, 2013 2:16:09PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: Site Starting: 1-3an-2012 Ending: 31-Dec-2012 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit.

D. Gross Alpha Activity

1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Ci uCi/mL G

uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 2.06E-02 1.28E-09

2. 30E +01 1.43E-06 0.OOE-i0O 0.OOE+00 0.OOE+00 0.OOE+00 1.13E+06 1.61E+10 0.00E+00 2.94E-02 1.15E-10 4.24E+01 1.66E-07 4.02E-03 1.57E-11 0.OOE+00 O.OOE+0O 1.44E+08 2.56E+11 O.OOE+00 1.80E-02 2.59E-10 7.90E+01
1. 14E-06 1.44E-03 2.07E-11 0.OOE+00 0.OOE+00 1.20E+08 6.96E+10 0.OOE+00 6.86E-03 1.25E-10 7.78E+I01 1.42E-06 4.35E-04 7.94E-12 0.OOE+00 0.OOE+00 2.14E+07 5.48E+10 0.OOE+00 7.49E-02 1.89E-10 2.22E+02 5.61E-07 5.89E-03 1.49E-11 0.OOE+00 0.OOE+00 2.87E+08 3.96E+11 0.OOE+00 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

PRIM-tint MiuLmmtlxti sofmarc~

Page 1 of 1 Monday, February 18, 2013 2:23:21PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Total Release A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 1.03E-02 1.28E-09 1.15E+01 1.43E-06 0.CaE+00 0.OOE+O0 O.OOE+00 0.OOE+00 5.64E+05 8.04E+09 O.OOE+00 1.47E-02 1.15E-10 2.12E+01 1.66E-07 2.01E-03 1.57E-11 0.OQE+0O Q.OOE+O0 7.22E+07 1.28E+11 0.OOE+O0 9.01E-03 2.59E-10 3.95E+01
1. 14E-06 7.22E-04 2.07E-11 O.OOE+00 0.OOE+O0 5.99E+07 3.48E+10 0.OOE+00 3.43E-03 1.25E-10 3.89E+01 1.42E-06 2.18SE-04 7.94E-12 0.OOE-i00 0.OOE+0O 1.07E+07 2.74E+10 0.OOE+00 3.74E-02 1.89E-10 1.11E+02 5.61E-07 2.95E-03 1.49E-1 1 0.OOE+0C 0.OOE-i00 1.43 E+I08 1.98E+/-11 0.OOE+00 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Effluent Nklmmt S~tVap r

L Page 1 of 1 Monday, February 18, 2013 2:32:22PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: PSL2 Starting: l-Jan-2012 Ending: 31-Dec-2012 Total Release A. Fission and Activation Products

1. Total Release 2, Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Uquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty Ci uCi/mL Ci uCmL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 1.03E-02 1.28E-09
1. 15E+01 1.43 E-06 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 5.64E+05 8.04E+I09 0.OOE-i00 1.47E-02 1.15E-10 2.12E+01 1.66E-07 2.01E-03 1.57E-11 0.OOE+0O O.OOE+00 7.22E+07 1.28E+11 0.OOE+00 9.0 1E-03 2.59E-10 3.95E+01 1.14E-06 7.22E-04 2.07E-11 O.OOE+00 0.OOE+00 5.99E+07 3.48E+ 10 0.OOE+00 3.43E-03 1.25E-10 3.89E+01 1.42E-06
2. 1E-04 7.94E-12 O.OOE+0O 0.OOE+00 1.07E+07 2.74E+ 10 0.OOE+00 3.74E-02 1.89E-10 1.11E+02 5.61E-07 2.95E-03 1.49E-11 0.OOE+00 0.0OE+00 1.43E+08 1.98E+11 0.OOE+00 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

FloCjda Power & Light, St. Lucie Power Plant 2/18/2013 14:23 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit:

Starting: 1-Jan-2012 PSL1 Ending: 31-Dec-2012 Batch Mode Nuclides Released A. Fission and Activation Products C-14 Na-24 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Br-82 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Tc-99m Ru-103 Ag-1Orm Sn-113 Sb-122 Sb-124 Sb-125 Te-129m Te-132 1-131 Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 7.05E-03 O.OOE+0O 1.42E-04.

1.80E-05 1.67E-03 2.35E-05 0.OOE+00 3.66E-04 1.65E-04 4.74E-06

2. 13E-06 0.OOE+O0 7.50E-05 6.09E-05 1.49E-04 2.33E-04 O.OOE+OO 1.22E-06 1.88E-04 0.OOE+OO 0.OOE+0O 3.27E-05 1.04E-04 O.OOE+0O 0.OOE+OO 0.OOE+00 1.08E-02 0-0OE+00 4-23E-05 1-04E-04 1.03E-03 3.06E-05 1.83E-06 4-38E-04 7.43E-04 7.77E-06 1-22E-06 1-45E-05 1-42E-04 0.OOE+OO 2.65E-04 3-88E-04 0.COE+0O 0-0OE+00 3-51E-04 1.80E-06 0-OOE+00 1-32E-05 3.51E-04 0.OOE+00 O.OOE+0O 0.OOE-e00 2.67E-03 4.98E-06 5.41E-04 8.52E-05 0.OOE+Q0 3-66E-05 1.10E-05 6.85E-04 5.96E-04 3.28E-05 3.81E-06 2.35E-05 8.72E-05 1.59E-04 1.49E-04 4.30E-04 1.38E-06 2.40E-06 3.48E-04 1.25E-05 3.44E-05 6.08E-04 2.27E-03 1.56E-04 1.41E-05 4.29E-06 9.36E-04 O.OOE+00 2.96E-04 5.81E-05 0.OOE--00 1.13E-05 2.65E-06 9.16E-04 3.64E-04 1.97E-06 9.11E-07 O.OOE+OO 7.34E-05 5.35E-05 1.24E-04 1.45E-04 0.OOE+OO O.OOE+OO
1. 16E-04 3.19E-06 O.OOE+0O 2.34E-05 1.93E-04 8.54E-05 O.OOE+0O 3.96E-06 Annual 2.14E-02 4.98E-06 1.02E-03 2.65E-04 2.70E-03 1.02E-04 1.54E-05 2.41E-03 1.87E-03 4.73E-05 8,07E-06 3.80E-05 3.78E-04 2.73E-04 6.87E-04 1.20E-03 1.38E-06 3.62E-06 1.00E-03 1.74E-05 3.44E-05 6.77E-04 2.92E-03 2.41E-04 1.41E-05 8.25E-06 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:23 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released 1-132 1-133 1-134 Cs-136 Cs-137 Cs-138 Ba-140 Total For Period Units Ci Ci Ci 0

Ci Ci Ci Ci 1ST Quarter O.OOE+00 0.OOE+00 O.OOE+0O 0.OOE+00 4.97E-06 0.00E+00 5.34E-06 1.03E-02 2ND Quarter O.OOE+00 0.OOE+00 0.00E+00 1.43E-06 3.18E-06 O.OOE+00 0.OOE+00 1.47E-02 3RD Quarter 7.63E-06

1. 18E-05 1.69E-06 0.00E+00 9.92E-06 O.OOE+00 1.34E-05 9.01E-03 4TH Quarter 0.OOE+00 0.OOE+00 0.OOE+00 2.34E-06 2.57E-06 1.51E-05 0.OOE+00 3.43E-03 Annual 7.63E-06 1.18E-05 1.69E-06 3.77E-06 2.06E-05 1.51E-05 1.87E-05 3.74E-02 B. Tritium H-3 Ci 1.15E+01 2.12E+01 3.95E+01 3.89E+01 1.11E+02 C. Dissolved and Entrained Gases Ar-41 Xe-133m Xe-133 Xe-135m Xe-135 Total For Period Ci Ci Ci Ci Ci Ci O.OQE+0O 0.OOE+OO 0.QOE+0O O.OOE+O0 O.OOE+OO O.OOE+OO 0.OOE--00 O.OOE+00 2.01E-03 O.OOE+0O 0.OOE+OO 2.01E-03 2.93E-06 0.OOE+0O 6.61E-04 0.OOE+0O 5.79E-05 7.22E-04 0.OOE+00 1.35E-05 1.61E-04 3.21E-06 3.96E-05 2.18E-04 2.93E-06 1.351E-05 2.83E-03 3.21E-06 9.74E-05 2.95E-03 D. Gross Alpha Activity No Nuclides Found Ci 0.00E+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:26 Page 2 of 3 Reg. Guide 1.21, Table 2B,, Liquid Effluents - Batch Mode Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual C-14 Na-24 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Br-82 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Tc-99m Ru-103 Ag-110in Sn-113 Sb-122 Sb-124 Sb-125 Te-129m Te-132 1-131 7.05E-03 O.OOE+00 1.42E-04 1.80E-05 1.67E-03 2.35E-05 0.OOE+00 3.66E-04 1.65E-04 4.74E-06 2.13E-06 O.OOE+00 7.50E-05 6.09E-05 1.49E-04 2.33E-04 O.OOE+00 1.22E-06 1.88E-04 O.OOE+00 O.OOE+O0 3.27E-05 1.04E-04 O.OOE+O0 0.OOE+00 O.OOE+0O 1.08E-02 O.OOE+OO 4.23E-05 1.04E-04 1.03E-03 3.06E-05 1.83E-06 4-38E-04 7.43E-04 7.77E-06 1.22E-06 1.45E-05 1.42E-04 0.COE+00 2.65E-04 3.88E-04 0.OOE+0O 0.OOE+0O 3.51E-04 1.80E-06 O.OOE+OO 1.32E-05 3.5 1E-04 0.OOE+00 O.QOE+QO 0.OOE+00 2.67E-03 4.98E-06 5.41E-04 8.52E-05 0.OOE+00 3.66E-05

1. 10E-05 6.85E-04 5.96E-04 3.28E-05 3.81E-06 2.35E-05 8.72E-05 1.59E-04 1.49E-04 4.30E-04 1.38E-06 2.40E-06 3.48E-04 1.25E-05 3.44E-05 6.08E-04 2.27E-03 1.56E-04 1.41E-05 4.29E-06 9.36 E-04 O.OaE+00 2.96 E-04 5.81E-05 0.OOE+00 1.13E-05 2.65E-06 9.16E-04 3.64E-04 1.97E-06 9.11E-07 0.OaE+0O 7.34E-05 5.35E-05 1.24E-04 1.45E-04 0.OOE+0O 0.OOE+OO 1.16E-04 3.19E-06 0.OOE+00 2.34E-05 1.93E-04 8.54E-05 0.OQE+0O 3.96E-06 2.14E-02 4.98E-06 1.02E-03 2.65E-04 2.70E-03 1.02E-04 1.54E-05 2.41E-03 1.87E-03 4.73E-05 8.07E-06 3.80E-05 3.78E-04 2.73E-04 6.87E-04 1.20E-03 1.38E-06 3.62E-06 1.OOE-03 1.74E-05 3.44E-05 6.77E-04 2.92E-03 2.41E-04 1.41E-05 8.25E-06 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/18/2013 14:26 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released 1-132 1-133 1-134 Cs-136 Cs-137 Cs-138 Ba-140 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 4.97E-06 O.OOE+00 5.34E-06 1.03E-02 2ND Quarter 0.0oE+00 O.OOE+00 0.OOE+00 1.43E-06 3.18E-06 O.OOE+00 O.OOE+00 1.47E-02 3RD Quarter 7.63E-06 1.18E-05 1.69E-06 0.OOE+00 9.92E-06 O.OOE+00 1.34E-05 9.01E-03 4TH Quarter 0.OOE+00 O.OOE+00 O.OOE+00 2.34E-06 2.57E-06 1.51E-05 0.OOE+00 3.43E-03 Annual 7.63E-06

1. 18E-05 1.69E-06 3.77E-06 2.06E-05 1.51E-05 1.87E-05 3.74E-02 B. Tritium H-3 Ci 1.15E+O1 2.12E+01 3.95E+01 3.89E+01 1.11E+02 C. Dissolved and Entrained Gases Ar-41 Xe-133m Xe-133 Xe-135m Xe-135 Total For Period D. Gross Alpha Activity No Nuclides Found Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+Q0 O.OOE+OO 0.0OE+00 O.OOE+OO 2.01E-03 0.OOE+00 0.OOE+OO 2.01E-03 2.93E-06 0.OOE+00 6.61E-04 0.OOE+00 5.79E-05 7.22E-04 0.OOE+00 1.35E-05 1.61E-04 3.21E-06 3.96E-05 2.18E-04 2.93E-06 1.35E-05 2.83E-03 3.21E-06 9.74E-05 2.95E-03 Ci 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

~:j~

~2 Eff1u~~rn M~in~.,tmetit 9~k~v.~are Page 1 of 3 Monday, February 18, 2013 2:16:45PM Florida Power & Light St. Lucie Power Plant Nuclides Released A. Fission and Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity No Nuclides Found Reg. Guide 1.21, Table 2B, Liquid Effluents - Continuous Mode Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter Ci O.OOE+0O O.OOE+O0 O.OOE+00 Ci 0.OOE+00 O.OOE+00 0.00E+00 Ci 0.OOE+00 0.OOE+00 0.OOE+00 Ci O.OOE+00 O.OOE+00 O.OOE+00 4TH Quarter 0.OOE+00 0.OOE+00 0.OOE+00 o.O0E+00 Annual O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

NRC Regulatory Guide 1.21 Reports Page 1

Report Date :

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Percent Cutoff:

1 Waste Stream : Resins Filters and Evap Bottoms High Integrity Container Waste Stream : Dry Active Waste DAW 20' Sealand PZR Heaters Waste F

Volume M

Curies

%Error Class Ft^3 M^3 Shipped (Ci)

A 3.76E+04 1.07E+03 9.63E+00

+/-25%

B 0.OOE+00 0.OOE+00 0.OOE+00

+/-25%

C 0.OOE+00 0.OOE+00 0.OOE+00

+/-25%

All 3.76E+04 1.07E+03 9.63E+00

+/-25%

Waste Stream : Irradiated Components Waste Volume Curies

% Error Class FtA3 MA3 Shipped (Ci)

A 0.OOE+00 0.OOE+00 0.OOE+00

+1-25%

B 0.OOE+00 0.OOE+00 0.00E+00

+1-25%

C 0.OOE+00 0.00E+00 0.00E+00

+/-25%

All 0.OOE+00 0.OOE+00 0.OOE+00

+/-25%

NRC Regulatory Guide 1.21 Reports Page 2

Report Date:

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Percent Cutoff:

1 Waste Stream : Other Waste Combined Packages Debris Intermodal 2012 waste oil Waste Stream : Sum of All 4 Categories Combined Packages DAW20' Sealand 2012 waste oil Debris Intermodal PZR Heaters Waste Volume Curies

% Error Class FtA3 MA3 Shipped (Ci)

A 5,21E+04 1,47E+03 1.62E+01

+1-25%

B 0.OOE+00 0,00E+00 0.OOE+00

+/-25%

C 0.OOE+00 0.00E+00 0.00E+00

+/-25%

All 5.21E+04 1,47E+03 1.62E+01

+/-25%

-Combined Waste Type Shipment, Major Volume Waste Type Shown

NRC Regulatory Guide 1.21 Reports Page 1

Report Date:

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Number of Shipments Mode of Transportation Destination 2

Hittman Transport (TN)

Clive CWF 26 Hittman Transport (TN)

Energy Solutions, (DTK) Gallaher Road 22 Hittman Transport (TN)

EnergySolutions Bear Creek 3

Hittman Transport (SC)

EnergySolutions LLC.

1 Hittman Transport (TN)

EnergySolutions LLC.

NRC Regulatory Guide 1.21 Reports Page I

Report Date :

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Percent Cutoff:

1 Resins, Filters, and Evap Bottom Waste Class A Nuclide Name Percent Abundance Curies H-3 22.945%

1.26E+00 C-14 1.890%

1.04E-01 Mn-54 1.274%

7.OOE-02 Fe-55 16.960%

9.32E-01 Co-58 16.338%

8.98E-01 Co-60 9.359%

5.15E-01 Ni-63 26.299%

1.45E+00 Ag-110m 1.108%

6.09E-02 Sb-125 2.680%

1.47E-01 Resins, Filters, and Evap Bottom Waste Class All Nuclide Name Percent Abundance Curies H-3 22.945%

1.26E+00 C-14 1.890%

1.04E-01 Mn-54 1.274%

7.OOE-02 Fe-55 16.960%

9.32E-01 Co-58.

16.338%

8.98E-01 Co-60 9.359%

5.15E-01 Ni-63 26.299%

1.45E+00 Ag-110m 1.108%

6,09E-02 Sb-125 2.680%

1.47E-01 Dry Active Waste Waste Class A Nuclide Name Percent Abundance Curies Mn-54 6.043%

5.82E-01 Fe-55 29.396%

2.83E+00 Co-58 7.230%

6.96E-01 Co-60 45.444%

4.38E+00 Ni-63 5.017%

4.83E-01 Nb-95 1.101%

1.06E-01 Cs-137 1.511%

1.46E-01 Dry Active Waste Waste Class All Nuclide Name Percent Abundance Curies Mn-54 6.043%

5.82E-01 Fe-55 29.396%

2.83E+00 Co-58 7.230%

6.96E-01 Co-60 45.444%

4.38E+00 Ni-63 5.017%

4.83E-01 Nb-95 1.101%

1.06E-01 Cs-137 1.511%

1.46E-01 Other Waste Waste Class A

NRC Regulatory Guide 1.21 Reports Page 2

Report Date:

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Percent Cutoff:

1 Nuclide Name Percent Abundance Curies Fe-55 52.624%

5.68E-01 Co-58 3.675%

3.97E-02 Co-60 14.985%

1.62E-01 Ni-63 15.030%

1.62E-01 Zr-95 1.269%

1.37E-02 Nb-95 2.532%

2.73E-02 Ag-110m 1.751%

1.89E-02 Cs-137 5.119%

5.53E-02 Other Waste Waste Class All Nuclide Name Percent Abundance Curies Fe-55 52.624%

5.68E-01 Co-58 3.675%

3.97E-02 Co-60 14.985%

1.62E-01 Ni-63 15.030%

1.62E-01 Zr-95 1.269%

1.37E-02 Nb-95 2,532%

2.73E-02 Ag-110m 1.751%

1.89E-02 Cs-137 5.119%

5.53E-02 Sum of All 4 Categories Waste Class A Nuclide Name Percent Abundance Curies H-3 8.016%

1.30E+00 Mn-54 4.087%

6.62E-01 Fe-55 26.725%

4.33E+00 Co-58 10.083%

1.63E+00 Co-60 31.175%

5.05E+00 Ni-63 12.903%

2.09E+00 Sb-125 1.526%

2.47E-01 Cs-137 1.301%

2.11E-01 Sum of All 4 Categories Waste Class All Nuclide Name Percent Abundance Curies H-3 8.016%

1.30E+00 Mn-54 4.087%

6.62E-01 Fe-55 26.725%

4.33E+00 Co-58 10.083%

1.63E+00 Co-60 31.175%

5.05E+00 Ni-63 12.903%

2.09E+00 Sb-125 1.526%

2.47E-01 Cs-137 1.301%

2.11E-01

NRC Regulatory Guide 1.21 Reports Page I

Report Date :

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Manifest Number Date Shipped Waste Volume Used Burial volume Used FPL/PSL 12-189 11/29/2012 Yes FPL/PSL 12-178 10/17/2012 Yes FPL/PSL 12-174 10/11/2012 Yes FPUPSL 12-173 10/9/2012 Yes FPUPSL 12-136 8/22/2012 Yes FPL/PSL 12-130 8/14/2012 Yes FPL/PSL 12-125 8/10/2012 Yes FPL/PSL 12-114 6/7/2012 Yes FPUPSL 12-107 5/9/2012 Yes FPLJPSL 12-1 04 5/3/2012 Yes FPUPSL 12-103 5/212012 Yes FPL/PSL 12-102 5/2/2012 Yes FPL/PSL 12-100 5/1/2012 Yes FPL/PSL 12-99 5/1/2012 Yes FPUPSL 12-98 4/30/2012 Yes FPL PSL 12-093 4/26/2012 Yes FPL/PSL 12-94 4/25/2012 Yes FPUPSL 12-97 4/25/2012 Yes FPUPSL 12-96 4/25/2012 Yes FPUPSL 12-95 4/24/2012 Yes FPL/PSL 12-91 4/12/2012 Yes FPLUPSL 12-83 3/28/2012 Yes FPL/PSL 12-82 3/28/2012 Yes FPLIPSL 12-78 3/26/2012 Yes FPL/PSL 12-81 3/26/2012 Yes FPL/PSL 12-80 3/26/2012 Yes FPL/PSL 12-79 3/26/2012 Yes FPUPSL 12-73 3/23/2012 Yes FPL/PSL 12-68 3/23/2012 Yes FPL/PSL 12-75 3/23/2012 Yes FPL/PSL 12-76 3/23/2012 Yes FPUPSL 12-74 3/23/2012 Yes FPL/PSL 12-71 3/21/2012 Yes FPL/PSL 12-70 3/21/2012 Yes FPL/PSL 12-69 3/21/2012 Yes FLPUPSL 12-64 3/19/2012 Yes FPL/PSL 12-63 3/19/2012 Yes

NRC Regulatory Guide 1.21 Reports Page 2

Report Date :

2/11/2013 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2012 to 12/31/2012 Manifest Number Date Shipped Waste Volume Used Bural volume Used FPL/PSL 12-66 3/19/2012 Yes FPL/PSL 12-65 3/19/2012 Yes FPL/PSL 12-56 3/8/2012 Yes FPL/PSL 12-55 3/7/2012 Yes FPL/PSL 12-52 3/1/2012 Yes FPL/PSL 12-51 3/1/2012 Yes FPL/PSL 12-48 2/28/2012 Yes FPL/PSL 12-47 2/28/2012 Yes FPL/PSL 12-21 2/16/2012 Yes FPL/PSL 12-19 2/9/2012 Yes FPL/PSL 12-18 2/9/2012 Yes FPL/PSL 12-36 2/2/2012 Yes FPL/PSL 12-28 1/25/2012 Yes FPL/PSL 12-22 1/19/2012 Yes FPL/PSL 12-10 1/11/2012 Yes FPL/PSL 12-05 1/5/2012 Yes FPL/PSL 12-002 1/3/2012 Yes

Efflitent Ntjatzkx Utfl E S (AW re Page 1 of 1 Monday, February 18, 2013 2:14:44PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 1.07E-01 2ND Quarter 1.65E-01 3RD Quarter 1.22E-01 4TH Quarter 8.32E-02 Annual 4.77E-01 Liver mRem 1.10E-01 1.66E-01 1.32E-01 8.90E-02 4.97E-01 Limit mRem Percent of Limit Total Body mRem 1.1OE-01 1.65E-01 1.32E-01 8.90E-02 4.97E-01 Limit mRem Percent of Limit Thyroid mRem 1.10E-01 1.65E-01 1.32E-01 8.91E-02 4.97E-01 Limit mRem Percent of Limit Kidney mRem 1.41E-02 1.99E-02 1.91E-02 1.24E-02 6.56E-02 Limit mRem Percent of Limit Lung mRemn 1,10E-01 1.65E-01 1.32E-01 8.90E-02 4,97E-01 Limit mRem Percent of Limit GI-Lli mRem 1.10E-01 1.65E-01 1.32E-01 8.90E-02 4.97E-01 Limit mRem Percent of Limit 0

User: AI Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

ýTh-AA q

EM Page 1 of 1 Monday, February 18, 2013 2:22:19PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter O.OOE+O0 2ND Quarter 5.79E-02 3RD Quarter 8.35E-02 4TH Quarter Annual 8.32E-02 2.25E-01 Liver mRem 1.24E-03 5.82E-02 9.04E-02 8.80E-02 2.38E-01 Limit mRem Percent of Limit Total Body mRern 1.24E-03 5.80E-02 9.01E-02 8.80E-02 2.37E-01 Limit mRem Percent of Limit Thyroid mRem 1.24E-03 5.80E-02 9.01E-02 8.80E-02 2.37E-01 Limit mRem Percent of Limit Kidney mRem 5.39E-04 7.01E-03 1.30E-02 1.20E-02 3.25E-02 Limit mRem Percent of Limit Lung mRem 1.24E-03 5.80E-02 9.01E-02 8.80E-02 2.37E-01 Limit mRem Percent of Limit GI-Lli mRem 1.24E-03 5.80E-02 9.01E-02 8.80E-02 2.37E-01 Limit mRem Percent of Limit User: AI Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

1EJfluetit Mrtugettziet %oftw~are Page 1 of 1 Monday, February 18, 2013 2:25:20PM Florida Power & Ught St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL2 Starting: 1-3an-2012 Ending: 31-Dec-2012 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 1.07E-01 2ND Quarter 1.07E-01 3RD Quarter 3.83E-02 4TH Quarter 2.33E-07 Annual 2.52E-01 Liver mRem 1.09E-01 1.07E-01 4.19E-02 9.92E-04 2.59E-01 Limit mRern Percent of Limit Total Body mRem 1.09E-01 1.07E-01 4.19E-02 9.92E-04 2.59E-01 Limit mRem Percent of Limit Thyroid mRem 1.09E-01 1.07E-01 4.20E-02 1.08E-03 2.59E-01 Limit mRem Percent of Limit Kidney mRem 1.36E-02 1.29E-02 6.12E-03 4.33E-04 3.30E-02 Limit mRem Percent of Limit Lung mRem 1.09E-01 1.07E-01 4.19E-02 9.92E-04 2.59E-01 Umit mRem Percent of Limit GI-Ui mRem 1.09E-01 1.07E-01 4.19E-02 9.92E-04 2.59E-01 Umit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

_EMS Effltwnt Nbnap*ýrntrkt Ix-dwarr Page 1 of 1 Monday, February 18, 2013 2:14:26PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 NG Dose Gamma Air Limit Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter mRad 1.22E-04 8.07E-04 1.67E-03 mRad 4TH Quarter Annual 2.0OE-04 2.80E-03 Beta Air mRad 8.48E-05 3.46E-04 6.44E-04 9.96E-05 1.18E-03 Limit mRad Percent of Limit NG Total Body mRem 1.15E-04 7'67E-04 1.61E-03 1.90E-04 2.68E-03 ULmit mRem Percent of Limit NG Skin mRem 2.03E-04 1.14E-03 2.37E-03 2.99E-04 4.OOE-03 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

j!Effluient NimagevMert ScIware Page 1 of 1 Monday, February 18, 2013 2:22:06PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 NG Dose

.Gamma Air Limit Units mRad mRad 1ST Quarter 2ND Quarter 3RD Quarter 1.66E-08 8.30E-05 9.17E-04 4TH Quarter Annual 1.73E-04 1.17E-03 Percent of Limit Beta Air mRad 4.05E-08 9.99E-05 3.58E-04 8.33E-05 5.41E-04 Limit mRad Percent of Limit NG Total Body mRem 1.45E-08 7.58E-05 8.82E-04 1.64E-04 1.12E-03 Limit mRem Percent of Limit NG Skin mRem 3.42E-08 1.38E-04 1.33E-03 2.59E-04 1.73E-03 Limit mRem Percent of Limit User, Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Y 7A jI Monday, February Page I of 1 18, 2013 2:25:08PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 NG Dose Gamma Air Limit Percent of Limit Units mRad mRad 1ST Quarter 1.22E-04 2ND Quarter 7.24E-04 3RD Quarter 7.55E-04 4TH Quarter Annual 2.75E-05 1.63E-03 Beta Air mRad 8.48E-05 2.46E-04 2.87E-04 1.64E-05 6.34E-04 Limit mRad Percent of Limit NG Total Body mRem 1.15E-04 6.91E-04 7.23E-04 2.58E-05 1.56E-03 Limit mRem Percent of Limit NG Skin mRem 2.03E-04 9.97E-04 1.04E-03 3.96E-05 2.28E-03 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:59 Page 13 of 14 Gas Status Summary Report Thursday, February 21, 2013 13:59 Page 13 of 14 Period:

Ann, 2012 Site/Unit/Discharge Point:

Site Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body NW Site Boundary - In Infant 4,754E-01 4.958E-01 4.952E-01 WNW Site Boundary - I Infant 1.282E-05 1.282E-05 1.282E-05 Thyroid 4.954E-01 1.282E-05 Kidney 6.539E-02 1.282E-05 Lung 4.952E-01 1.282E-05 GI-UI1 4.952E-01 1.282E-05 Skin 0.OOOE+O0 O.OOOE+00 Maximum Doserate by Organ:

4.754E-01 4.958E-01 4.952E-01 4.954E-01 6.539E-02 4.952E-01 4.952E-01 0.000E+00 Maximum Organ Doserate (mRem/yr):

4.958E-01 Maximum Total Body Doserate (mRem/yr):

4.952E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)

Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr)

NW Site Boundary 2.793E-03 1.172E-03 2.670E-03 3.994E-03 WNW Site Boundary 2.406E-03 1.010E-03 2.300E-03 3.440E-03 Maximum NG Dose Rate:

2.793E-03 1.172E-03 2.670E-03 3.994E-03 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:59 Page 14 of 14 Gas Status Summary Report Thursday, February 21, 2013 13:59 Page 14 of 14 Period:

Ann, 2012 Site/Unit/Discharge Point:

Site Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res - Child SE Nearest Res - Infant SE Nearest Res - Teenager SE Visitor - Adult SSW Near Garden - Adult SSW Near Garden - Child SSW Near Garden -

WSW Near Milk - Adult WSW Near Milk - Child WSW Near Milk - Infant WSW Near Milk - Teenager Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 2.665E-05 2.668E-05 2.663E-05 2.662E-05 1.237E-05 2.063E-06 2.065E-06 2.060E-06 9.363E-06 2.390E-05 4.47BE-05 8.127E-06 Liver 2.664E-05 2,665E-05 2.663E-05 2.666E-05 1.237E-05 2.062E-06 2.063E-06 2.063E-06 1.104E-05 2.328E-05 4.955E-05 1.093E-05 Total Body 2.656E-05 2.648E-OS 2.646E-05 2.6S2E-05 1.233E-05 2.056E-06 2.051E-06 2.054E-06 8.875E-06 7.5081E-06 7.331E-06 3.850E-06 Thyroid 2.660E-05 2.664E-05 2.663E-05 2.662E-05 1.235E-05 2.059E-06 2.062E-06 2.061E-06 6.528E-06 1.001E-05 1.741E-05 2.717E-06 Kidney 2.652E-05 2.648E-O5 2.646E-05 2.652E-05 1.232E-05 2.054E-06 2.051E-06 2.054E-06 6.887E-06 7.027E-06 7.025E-06 2.827E-06 Lung 2.754E-05 2.780E-05 2.761E-05 2.808E-05 1.276E-05 2.123E-06 2.141E-06 2.161E-06 5.576E-06 7.074E-06 1.02BE-05 1.644E-06 GX-Ili 2.651E-05 2.647E-05 2.64SE-05 2.650E-05 1.23 1E-05 2.053E-06 2.050E-06 2.053E-06 4.870E-06 4.857E-06 4.858E-06 2.506E-07 Skin O.OOOE+O0 O.OOOE+O0 O.OOOE+00 0.000E+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.O00E+00 0.OOOE+00 0.OOOE+00 Maximum Dose by Organ:

Maximum Organ Dose (mRem):

4.47BE-05 4.955E-05 2.656E-05 2.664E-05 2.652E-05 2.808E-05 2.651E-05 0.0001E+t00 4.955E-05 Maximum Total Body Dose (mRem):

2.656E-05 Maximum Individual NG Dose Summary Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg Gamma (mRad)

Beta (mRad) 1.247E-03 5.230E-04 5.398E-04 9.458E-05 1.679E-04 2.265E-04 3.968E-05 7.043E-05 Total Body (mRem) 1.192E-03 5.160E-04 9.040E-05 1.605E-04 Skin (mRem) 1.783E-03 7.718E-04 1.352E-04 2.4OOE-04 Maximum NG Dose:

1.247E-03 5.230E-04 1.192E-03 1.783E-03 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:54 Page 8 of 9 Period:

Ann, 2012 Site/Unit/ Discharge Point:

PSL1 Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW Site Boundary - In Infant 2.239E-01 2.373E-01 2.367E-01 2.367E-01 3.243E-02 2.368E-01 2.367E-01 O.OOOE+00 WNW Site Boundary - I Infant 1.223E-05 1.223E-05 1.223E-05 1.223E-05 1.223E-05 1.223E-05 1.223E-05 O.OOOE+00 Maximum Doserate by Organ:

2.239E-01 2.373E&01 2.367E-01 2.367E-01 3.243E-02 2.368E-01 2.367E-01 O.00E+O0 Maximum Organ Doserate (mRem/yr):

2.373E-01 Maximum Total Body Doserate (mRem/yr):

2.367E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)

Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr)

NW Site Boundary 1.170E-03 5.395E-04 1.119E-03 1.721E-03 WNW Site Boundary 1.008E-03 4.647E-04 9.638E-04 1.483E-03 Maximum NG Dose Rate:

1.170E-03 5.395E-04 1.119E-03 1.721E-03 User: At Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:S4 Page 9 of 9 Gas Status Summary Report Thursday, February 21, 2013 13:54 Page 9 of 9 Period:

Ann, 2012 Site/Unit/Discharge Point:

PSL1 Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res - Child SE Nearest Res - Infant SE Nearest Res - Teenager SE Visitor - Adult SSW Near Garden - Adult SSW Near Garden - Child SSW Near Garden -

WSW Near Milk - Adult WSW Near Milk - Child WSW Near Milk - Infant WSW Near Milk - Teenager Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 2.486E-05 2.495E-05 2-491E-05 2.490E-05 1,154E-05 1.925E-06 1.931E-06 1.928E-06 8.401E-06 2.090E-05 3.884E-05 6.982E-06 Liver 2.490E-05 2.493E-05 2.492E-05 2.4941E-05 1.156E-05 1.927E-06 1.930E-06 1.930E-06 9.848E-06 2.037E-05 4.294E-05 9.389E-06 Total Body 2.485E-05 2.479E-05 2.477E-05 2.483E-05 1.154E-05 1.925E-06 1.9.20E-06 1.923E-06 7.990E-06 6.807E-06 6.646E-06 3.308E-06 Thyroid 2.476E-05 2.476E-05 2.476E-05 2.476E-05 1.150E-05 1.918E-06 1.918E-06 1.918E-06 4.433E-06 4.433E-06 4.433E-06 O.00O1E+00 Kiidney 2.481E-05 2.478E-05 2.477E-05 2.481E-05 1.152E-05 1.921E-06 1.920E-06 1.921E-06 6.274E-06 6.39SE-06 6.394E-06 2.418E-06 Lung 2.565E-05 2.579E-05 2.559E-05 2.603E-05 1.189E-05 1.979E-06 1.989E-06 2.005E-06 5.150E-06 6.429E-06 9.184E-06 1.39SE-06 GI-Ili 2.480E-05 2.477E-05 2.477E-05 2.480E-05 1.152E-05 1.921E-06 1-919E-06 1.921E-06 4.546E-06 4.535E-06 4.536E-06 2.169E-07 Skin 0.000E+00 0.000E+00 0.000E+00 O.OOOE+00 0.000E+00 0.0001E+00 O.OOOE+00 O.OOOE+O0 0.000E+00 o.o0oE+00 o.o0oE+00 O.OOE+00 Maximum Dose by Organ:

Maximum Organ Dose (mRem):

3.884E-05 4.294E-05 2.485E-05 2.476E-05 2.481E-05 2.603E-05 2.480E-05 0.000E+00 4.294E-05 Maximum Total Body Dose (mRem):

2.485E-05 Maximum Individual NG Dose Summary Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg Gamma (mRad)

Beta (mRad) 5.222E-04 2.408E-04 2.261E-04 3.962E-05 7.032E-05 1.043E-04 1.827E-05 3.242E-05 Total Body (mRem) 4.994E-04 2.162E-04 3.788E-05 6.725E-05 Skin (mRem) 7.682E-04 3.326E-04 5.828E-05 1.034E-04 Maximum NG Dose:

5.222E-04 2.408E-04 4.994E-04 7.682E-04 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:55 Page 8 of 9 Period:

Ann, 2012 Site/Unit/Discharge Point:

PSL2 Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW Site Boundary - In Infant 2.515E-01 2.586E-01 2.585E-01 2.587E-01 3.296E-02 2.585E-01 2.585E-01 O.O00E+00 WNW Site Boundary - I Infant 5.925E-07 5.925E-07 5.925E-07 5.925E-07 5.925E-07 5.925E-07 5.925E-07 0.OOOE+00 Maximum Doserate by Organ:

2.515E-01 2.586E-01 2.585E-01 2.587E-01 3.296E-02 2.585E-01 2.585E-01 O.OOOE+00 Maximum Organ Doserate (mRem/yr):

2.587E-01 Maximum Total Body Doserate (mRem/yr):

2.585E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)

Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr)

NW Site Boundary 1.623E-03 6.324E-04 1.551E-03 2.273E-03 WNW Site Boundary 1.398E-03 5.448E-04 1.336E-03 1.958E-03 Maximum NG Dose Rate:

1.623E-03 6.324E-04 1.551E-03 2.273E-03 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Thursday, February 21, 2013 13:55 Page 9 of 9 Period:

Ann, 2012 Site/Unit/Discharge Point:

PSL2 Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res - Child SE Nearest Res - Infant SE Nearest Res - Teenager SE Visitor - Adult SSW Near Garden - Adult SSW Near Garden - Child SSW Near Garden -

WSW Near Milk - Adult WSW Near Milk - Child WSW Near Milk - Infant WSW Near Milk - Teenager Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 1.790E-06 1.730E-06 1.721E-06 1.718E-06 8.284E-07 1.377E-07 1.336E-07 1.32BE-07 9.624E-07 3.00 1E-06 5.939E-06 1.145E-06 Liver 1.743E-06 1.717E-06 1.715E-06 1.7 18E-06 8.080E-07 1.345E-07 1.327E-07 1.328E-07 1.193E-06 2.913E-06 6.612E-06 1.53BE-06 Total Body 1.704E-06 1.690E-06 1.687E-06 1.696E-06 7.909E-07 1.318E-07 1.309E-07 1.313E-07 8.845E-07 7.003E-07 6.847E-07 5.417E-07 Thyroid 1.837E-06 1.882E-06 1.866E-06 1.863E-06 8.488E-07 1.409E-07 1.440E-07 1.427E-07 2.096E-06 5.57BE-06 1.298E-05 2.717E-06 Kidney 1.715E-06 1.69BE-06 1.689E-06 1.715E-06 7.954E-07 1.326E-07 1.314E-07 1.326E-07 6.134E-07 6.323E-07 6.312E-07 4.088E-07 Lung 1.88BE-06 2.006E-06 2.017E-06 2.046E-06 8.713E-07 1.445E-07 1.526E-07 1.553E-07 4.256E-07 6.454E-07 1.099E-06 2.464E-07 GI-Lti1 1.706E-06 1.695E-06 1.688E-06 1.706E-06 7.91SE-07 1.319E-07 1.312E-07 1.320E-07 3.243E-07 3.220E-07 3.219E-07 3.372E-08 Skin 0.OOOE+aO 0.0001E+00a a.oOO1E+00 0.OOOE+O0 0.OOOE+O0 o.0001E+00 0.OOOE+00 0.000E+00 O.OOOE+00 0.OOOE+00 0.00O1E+00 0.OOOE-l00 Maximum Dose by Organ:

Maximum Organ Dose (mRem):

5.939E-06 6.612E-06 1.704E-06 1.298E-05 1.715E-06 2.046E-06 1.706E-06 O.OOOE+00 1.298E-05 Maximum Total Body Dose (mRem):

1.704E-06 Maximum Individual NG Dose Summary Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg Gamma (mRad) 7.245E-04 3.137E-04 5.497E-05 9.757E-05 Beta (mRad) 2.822E-04 1.222E-04 2.141E-05 3.801E-05 Total Body (mRem) 6.923E-04 2.998E-04 5.252E-05 9.322E-05 Skin (mRem) 1.014E-03 4.392E-04 7.695E-05 1.366E-04 Maximum NG Dose:

7.245E-04 2.822E-04 6.923E-04 1.014E-03 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

J-Efluent Ma u rnent Soffimoe Page 1 of 1 Monday, February 18, 2013 2:14:10PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B,.Sec El - Doses to a member of the public due to Liquid Releases Unit: Site Starting: 1-Jan-2012 Ending: 31-Dec-2012 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 1.11E-02 2ND Quarter 4.86E-03 3RD Quarter 8.89E-04 4TH Quarter Annual 2.67E-04 1.71E-02 Liver mRem 4.51E-02 1.75E-02 2.13E-03 9.35E-04 6.57E-02 Limit mRem Percent of Limit Total Body mRem 1.31E-02 5.82E-03 1.63E-03 9.02E-04 2.15E-02 Limit mRem Percent of Limit Thyroid mRem 1.90E-03 1.74E-03 1.11E-03 6.76E-04 5.40E-03 Limit mRem Percent of Limit Kidney mRem 1.35E-03 1.27E-03 1.56E-03 8.24E-04 5.01E-03 Limit mRem Percent of Limit Lung mRem 5.16E-02 1.99E-02 3.65E-03 8.49E-04 7.60E-02 Limit mRem Percent of Limit GI-LiI mRem 3.51E-02 2.58E-02 2.02E-02 1.31E-02 9.42E-02 Limit mRem Percent of Limit User: AI Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

P EMS Page 1 of 1 Monday, February 18, 2013 2:21:52PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El - Doses to a member of the public due to Liquid Releases Unit: PSL1 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 5.55E-03 2ND Quarter 2.43E-03 3RD Quarter 4.44E-04 4TH Quarter Annual 1.33E-04 8.56E-03 Liver mRern 2.25E-02 8.77E-03 1.06E-03 4.67E-04 3.28E-02 Limit mRem Percent of Limit Total Body mRem 6.56E-03 2.91E-03 8.17E-04 4.51E-04 1.07E-02 Limit mRem Percent of Limit 0

Thyroid mRem 9.49E-04 8.69E-04 5.57E-04 3.38E-04 2.70E-03 Limit mRem Percent of Limit Kidney rnRem 6.74E-04 6.35E-04 7.82E-04 4.12E-04 2.50E-03 Limit mRem Percent of Limit Lung mRem 2.58E-02 9.94E-03 1.83E-03 4.25E-04 3.80E-02 Limit mRem Percent of Limit GI-Ui mRern 1.76E-02 1.29E-02 1.01E-02 6.53E-03 4.71E-02 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

EMSI Page 1 of 1 Monday, February 18, 2013 2:24:53PM Florida Power & Light St. Lude Power Plant Reg. Guide 1.21, App B, Sec El - Doses to a member of the public due to Liquid Releases Unit: PSL2 Starting: 1-Jan-2012 Ending: 31-Dec-2012 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 5.55E-03 2ND Quarter 2.43E-03 3RD Quarter 4.44E-04 4TH Quarter Annual 1.33E-04 8.56E-03 Liver mRem 2.25E-02 8.77E-03 1.06E-03 4.67E-04 3.28E-02 Limit mRem Percent of Limit Total Body mRem 6.56E-03 2.91E-03 8.17E-04 4.51E-04 1.07E-02 Limit mRem Percent of Limit Thyroid mRem 9.49E-04 8.69E-04 5.57E-04 3.38E-04 2.70E-03 Limit mRem Percent of Limit Kidney mRem 6.74E-04 6.35E-04 7.82E-04 4.12E-04 2.50E-03 Limit mRem Percent of Limit Lung mRem 2.58E-02 9.94E-03 1.83E-03 4.25E-04 3.80E-02 Limit mRem Percent of Limit GI-LIi mRem 1.76E-02 1.29E-02 1.O1E-02 6.53E-03 4.71E-02 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Liquid Status Summary Report Thursday, February 21, 2013 13:53 Page 6 of 6 Period:

Ann, 2012 Site/Unit/Discharge Point:

PSL1 Liquid Dose Summary - Note: All Doses in mRem Receptor Aggroup Bone Liver Total Body Thyroid Kidney Lung GI-Ui Skin Uquid Receptor - Teenager Teenager 8.556E-03 3.285E-02 1.074E-02 2.326E-03 2.503E-03 3.802E-02 4.708E-02 0.OOOE+00 Uquid Recptor - Child Child 5.170E-03 1.617E-02 6.560E-03 2.698E-03 1.089E-03 1.843E-02 2.060E-02 0.000E+00 Maximum Dose by Organ:

8.556E-03 3.285E-02 1.074E-02 2.698E-03 2.503E-03 3.802E-02 4.708E-02 O.OOOE+00 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

4.708E-02 1.074E-02 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Liquid Status Summary Report Thursday, February 21, 2013 13:S3 Page 6 of 6 Period:

Ann, 2012 Site/Unit/Discharge Point:

PSL2 Liquid Dose Summary - Note: All Doses in mRem Receptor AgCgrouD Bone Lier Total Body Thyroid Kidney Lung GI-U.i Skin Liquid Receptor - Teenager Teenager 8.556E-03 3.285E-02 1.074E-02 2.326E-03 2.503E-03 3.802E-02 4.708E-02 O.OOE+00 Uquid Recptor - Child Child 5.170E-03 1.617E-02 6.560E-03 2.698E-03 1.089E-03 1.843E-02 2.060E-02 0.000E+00 Maximum Dose by Organ:

8.556E-03 3.285E-02 1.074E-02 2.698E-03 2.503E-03 3.802E-02 4.708E-02 0.000E+00 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

4.708E-02 1.074E-02 User: A] Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Liquid Status Summary Report Thursday, February 21, 2013 13:54 Page 6 of 6 Period:

Ann, 2012 Site/Unit/Discharge Point:

Site Liquid Dose Summary - Note: All Doses in mRem Receto Aeroup Bone LLV_qr Total Body Thyroid Kidney Lung GI-Llii Skin Liquid Receptor - Teenager Teenager 1.711E-02 6.570E-02 2.147E-02 4.651E-03 5.005E-03 7.603E-02 9.415E-02 0.000E+00 Liquid Recptor - Child Child 1.034E-02 3.235E-02 1.312E-02 5.397E-03 2.177E-03 3.687E-02 4.121E-02 0.0001E+00 Maximum Dose by Organ:

1.711E-02 6.570E-02 2.147E-02 5.397E-03 5.005E-03 7.603E-02 9.415E-02 O.OOOE+00 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

9.415E-02 2.147E-02 User: All Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS I AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 3.4 Visitor Dose Dose to a Member of the Public from Activities Inside the Site Boundary Assessment of radiation dose from radioactive effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY assumes the VISITOR to be a lifeguard at the Walton Rocks Beach recreation area. The visitor is assumed to be onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1.6 kilometers in the South East Sector. The VISITOR received exposure from each of the two reactors on the site. Actual Met Data was used to calculate Visitor Dose for Calendar Year 2012.

VISITOR DOSE RESULTS FOR CALENDAR YEAR 2012 was:

Noble Gas Dose mrad Gamma Air Dose 2.36E-03 Beta Air Dose 9.92E-04 Gas, Particulate, Iodine, Carbon Dose mrem Bone 4.18E-01 Liver 4.36E-01 Thyroid 4.35E-01 Kidney 5.74E-02 Lung 4.35E-01 GI-LLI 4.35E-01 Total Body 4.35E-01