ML13007A112

From kanterella
Jump to navigation Jump to search
Kld TR-482, Rev. 2, Davis-Besse Nuclear Power Station Development of Evacuation Time Estimates, Part 7 of 8
ML13007A112
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 10/31/2012
From:
KLD Engineering, PC
To:
Office of Nuclear Reactor Regulation
References
L-12-441 KLD TR-482, Rev 2
Download: ML13007A112 (43)


Text

Grid 27__!W County Road 73 ECounty Road 73 7 5AEIigaj 0-Cherry C-)Thomas Dr Grid 29 297 1ý2 , -ý"" & 5655 Commerce Id'VS St 5.Davis-gesse Nuclear Power Station Unk-Node Analysis Network Figures=Grid 29 0.25 0.5 pa" Figure K-29 Link-Node Analysis Network-Grid 28 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-31 KLD Engineering, P.C.Rev. 2 Figure K-30 Link-Node Analysis Network-Grid 30 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-32 KLD Engineering, P.C.Rev. 2 Figure K-31 Link-Node Analysis Network-Grid 31 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-33 KLD Engineering, P.C.Rev. 2 Figure K-32 Link-Node Analysis Network-Grid 32 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-34 KLD Engineering, P.C.Rev. 2 Table K-1. Evacuation Roadway Network Characteristics Up- Dw-N. Sauato Fre Stea Stea Roda of Lan Shudr Fow Foa 1 1 155 SR 2 collector 10544 1 12 4 1700 60 1 minor 2 1 156 SR 2 arterial 10664 2 12 4 1900 60 1 3 2 447 US-6 collector 4746 1 12 4 1700 60 32 4 3 4 SR 53 collector 2272 1 12 4 1750 40 30 5 3 10 SR 53 collector 707 1 12 4 1700 60 30 6 4 3 SR 53 collector 2272 1 12 4 1750 40 30 7 4 5 SR 53 collector 440 1 12 4 1700 40 30 minor 8 5 4 SR 53 arterial 441 1 12 4 1750 40 30 9 5 6 SR 53 collector 310 1 12 4 1700 60 30 10 6 5 SR 53 collector 310 1 12 4 1700 40 30 11 6 7 SR 53 collector 2196 1 12 4 1700 60 30 freeway 12 6 28 SR 53 off-ramp to US-6 ramp 655 1 12 4 1700 40 30 13 7 6 SR 53 collector 2196 1 12 4 1700 60 30 14 7 499 SR 53 collector 245 1 12 4 1700 30 30 freeway 15 7 500 US 6 on-ramp from SR 53 ramp 904 1 12 4 1700 45 30 16 10 3 SR 53 collector 707 1 12 4 1750 40 30 17 10 11 SR 53 collector 5521 1 12 4 1700 60 30 18 11 10 SR 53 collector 5521 1 12 4 1700 0 30 minor 19 11 26 SR 53 arterial 1193 2 12 4 1750 60 28 minor 20 12 13 SR 53 arterial 895 2 12 4 1900 628 Davis-Besse Nuclear Power Station K-35 KLD Engineering, P.C.Evacuation Time Estimate Rev. 2 minor arterial 21 12 26 1 SR 53 1029 2 12 4 1750 60 28 freeway 22 12 291 SR 53 off-ramp to 1-90 ramp 447 1 12 4 1125 25 28 minor 23 13 12 SR 53 arterial 895 2 12 4 1900 60 28 24 13 14 SR 53 collector 3633 1 12 4 1700 60 28 freeway 25 13 293 SR 53 off-ramp to 1-90 ramp 1142 1 12 4 1700 40 28 26 14 13 SR 53 collector 3623 1 12 4 1700 60 28 27 14 27 SR 53 collector 4836 1 12 4 1700 60 28 28 15 16 SR 53 collector 2912 1 12 4 1700 60 24 29 15 35 SR 53 collector 6753 1 12 4 1700 60 23 30 16 15 SR 53 collector 2912 1 12 4 1700 60 24 31 16 17 SR 53 collector 1814 1 12 4 1700 60 24 32 17 16 SR 53 collector 1814 1 12 4 1700 60 24 33 17 18 SR 53 collector 3542 1 12 4 1700 60 24 34 18 17 SR 53 collector 3542 1 12 4 1700 60 24 35 18 19 SR 53 collector 1486 1 12 4 1700 60 24 36 19 18 SR 53 collector 1486 1 12 4 1700 60 24 37 19 20 SR 53 collector 3601 1 12 4 1700 60 24 38 20 19 SR 53 collector 3601 1 12 4 1700 60 24 39 20 21 SR 53 collector 5567 1 12 4 1700 60 24 40 21 20 SR 53 collector 5567 1 12 4 1700 60 24 41 21 22 SIR53 collector 5077 1 12 4 1700 60 24 42 22 21 SR 53 collector 5077 1 12 4 1700 60 24 43 22 23 SR 53 collector 5337 1 12 4 1700 60 12 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-36 KLD Engineering, P.C.Rev. 2 44 23 22 1SR 53 collector 5337 1 12 4 1700 60 12 45 23 24 SR 53 collector 3874 1 12 4 1700 60 13 46 24 23 SR 53 collector 3874 1 12 4 1700 60 13 minor 47 24 25 SR 53 arterial 1064 2 12 4 1900 60 13 freeway 48 24 103 SR 53 off-ramp to SR 2 ramp 943 1 12 4 1700 40 13 minor 49 25 24 SR 53 arterial 1064 2 12 4 1900 60 13 50 25 106 W Fremont Rd collector 2758 1 12 4 1700 55 13 minor 51 26 11 SR 53 arterial 1193 2 12 4 1900 60 28 minor 52 26 12 SR 53 arterial 1029 2 12 4 1900 60 28 53 27 14 SR 53 collector 4836 1 12 4 1700 60 28 54 27 35 SR 53 collector 3226 1 12 4 1700 60 23 freeway 55 28 6 SR 53 on-ramp from US-6 ramp 654 1 12 4 1900 40 30 freeway 56 28 29 US-6 on-ramp frpm SR 53 ramp 1346 1 12 4 1700 40 29 57 29 30 US-6 freeway 1375 2 12 8 2250 65 30 58 29 33 US-6 freeway 2435 2 12 8 2250 65 29 freeway 59 30 28 US-6 off-ramp to SR 53 ramp 1213 1 12 4 1200 25 30 60 30 29 US-6 freeway 1375 2 12 8 2250 65 30 61 30 31 US-6 freeway 348 2 12 4 2250 65 30 62 31 30 US-6 freeway 348 2 12 4 2250 65 30 63 31 32 US-6 freeway 1229 2 12 4 2250 65 30 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-37 KLD Engineering, P.C.Rev. 2 Up- ~~ ~ ~S Don o*auain Fe 64 31 500 US 6 off-ramp to SR 53 collector 1024 1 12 4 1700 30 30 65 32 31 US-6 freeway 1229 2 12 4 2250 65 30 66 32 34 US-6 freeway 6209 2 12 4 2250 65 30 67 33 29 US-6 freeway 2435 2 12 4 2250 65 29 68 33 36 US-6 freeway 809 2 12 4 2250 65 29 freeway 69 33 39 US-6 off-ramp to SR 19 ramp 993 1 12 4 1750 40 29 70 34 32 US-6 freeway 6209 2 12 4 2250 65 30 freeway 71 34 434 US-6 off-ramp to N 5th St ramp 1195 1 12 4 1750 45 30 72 34 435 US-20 freeway 1122 2 12 8 2250 65 30 73 35 15 SR 53 collector 6753 1 12 4 1700 60 24 74 35 27 SR 53 collector 3226 1 12 4 1700 60 23 75 36 33 US-6 freeway 809 2 12 4 2250 65 29 76 36 37 US-6 freeway 1075 2 12 4 2250 65 29 freeway 77 36 287 US-6 off-ramp to SR 19 ramp 625 1 12 4 1125 25 29 78 37 36 US-6 freeway 1075 2 12 4 2250 65 29 79 37 38 US-6 freeway 2788 2 12 4 2250 65 29 80 38 37 US-6 freeway 2788 2 12 4 2250 65 29 81 38 41 US-6 freeway 2038 3 12 4 2250 60 29 freeway 82 39 37 SR 19 off-ramp to US-6 ramp 1039 1 12 4 1700 40 29 minor 83 39 40 SR 19 arterial 1050 2 12 4 1750 55 29 minor 84 40 286 SR 19 arterial 758 4 1900 55 29 Davis-Besse Nuclear Power Station K-38 KLD Engineering, P.C.Evacuation Time Estimate Rev. 2 freeway 85 40 287 I SR 19 off-ramp to US-6 ramp 584 1 12 4 1350 30 29 freeway 86 41 43 US-6 off-ramp to US-20 ramp 2068 2 12 4 1900 60 26 87 4, 46 US-6 collector 2379 1 12 4 1700 60 29 88 42 38 US-6 freeway 2033 2 12 4 2250 60 29 US-6 on-ramp from US- freeway 89 43 42 20 ramp 2086 1 12 4 1700 60 26 US-20 on-ramp from US- freeway 90 43 44 6 ramp 1368 1 12 4 1700 60 26 freeway 91 44 43 US-20 off-ramp to US-6 ramp 1367 2 12 4 1900 60 26 92 44 45 US-20 collector 1124 1 12 4 1700 60 26 minor 93 44 48 US-20 arterial 2167 2 12 4 1900 60 26 minor 94 45 49 US-20 arterial 740 2 12 4 1900 60 26 freeway 95 46 52 US-6 off-ramp to US-20 ramp 1246 1 12 4 1700 60 29 96 46 53 US-6 collector 683 1 12 4 1700 60 26 freeway 97 47 44 US-20 ramp 2135 1 12 4 1700 60 26 minor 98 48 44 US-20 arterial 2167 2 12 4 1900 60 26 minor 99 48 54 US-20 arterial 14730 2 12 4 1900 60 26 minor 100 49 50 US-20 arterial 1318 2 12 4 1900 60 26 101 49 497 US-20 off-ramp to US-6 freeway 854 1 12 4 1700 60 26 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-39 KLD Engineering, P.C.Rev. 2 ramp minor 102 50 47 US-20 arterial 1146 2 12 4 1900 60 29 minor 103 50 51 US-20 arterial 1405 2 12 4 1900 60 29 minor 104 51 50 US-20 arterial 1405 2 12 4 1900 60 29 Exit minor Link 51 8051 US-20 arterial 1018 2 12 4 1900 60 29 freeway 105 52 42 US-6 ramp 999 1 12 4 1700 60 29 US-20 on-ramp from US- freeway 106 52 50 6 ramp 1038 1 12 4 1125 25 29 107 53 46 US-6 collector 683 1 12 4 1700 60 26 Exit Link 53 8053 US-6 collector 1106 1 12 4 1900 60 26 minor 108 54 48 US-20 arterial 14730 2 12 4 1900 60 26 minor 109 54 56 US-20 arterial 5407 2 12 4 1900 60 26 110 55 54 SR 590 collector 7748 1 12 4 1700 60 26 minor 111 56 54 US-20 arterial 5407 2 12 4 1900 60 26 minor 112 56 57 US-20 arterial 1643 2 12 4 1900 55 26 minor 113 57 56 US-20 arterial 1643 12 4 1900 55 26 minor 114 57 58 US-20 arterial 17214 2 12 4 1900 60 21 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-40 KLD Engineering, P.C.Rev. 2 58 minor arterial 115 57 US-20 17214 2 12 4 1900 60 21 minor 116 58 59 US-20 arterial 5974 2 12 4 1900 60 21 minor 117 59 58 US-20 arterial 5974 2 12 4 1900 60 21 Exit minor Link 59 8059 US-20 arterial 1461 2 12 4 1900 60 21 118 60 58 SR 51 collector 11478 1 12 4 1700 60 21 freeway 119 60 62 SR 51 off-ramp ramp 916 1 12 4 1350 30 21 120 61 60 SR 51 collector 4195 1 12 4 1700 60 21 freeway 121 62 63 SR 51 off-ramp to ramp 1356 1 12 4 1350 30 21 122 63 64 SR 51off ramp collector 1083 1 12 4 1700 40 21 freeway 123 64 65 On-ramp to 1-80 ramp 1578 1 12 4 1700 40 21 freeway 124 64 66 On-ramp to 1-90 ramp 2053 1 12 4 1125 25 21 125 65 67 1-90 freeway 2595 3 12 8 2250 70 21 126 65 70 1-80 freeway 2220 3 12 4 2250 70 21 freeway 127 66 67 On-ramp to 1-90 ramp 1424 1 12 4 1125 25 21 128 67 65 1-80 freeway 2595 3 12 4 2250 70 21 129 67 68 1-90 freeway 2219 3 12 4 2250 70 21 130 68 67 1-80 freeway 2219 3 12 4 2250 70 21 131 68 69 1-90 freeway 9667 3 12 4 2250 70 21 132 69 68 1-80 freeway 9667 3 12 4 2250 70 21 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-41 KLD Engineering, P.C.Rev. 2 Up Down No Sauato Fre Stem team Roadwa of Lan Shule Flo Flo Map Exit Link 69 8069 11-90 freeway 4032 3 12 4 2250 65 20 133 70 65 1-90 freeway 2220 3 12 4 2250 70 21 134 70 71 1-80 freeway 8448 3 12 4 2250 70 21 135 71 70 1-90 freeway 8448 3 12 4 2250 70 21 136 71 72 1-80 freeway 19131 3 12 4 2250 70 22 137 72 71 1-90 freeway 19131 3 12 4 2250 70 22 138 72 73 1-80 freeway 4384 3 12 4 2250 70 26 139 73 72 1-90 freeway 4384 3 12 4 2250 70 26 140 73 74 1-80 freeway 3542 3 12 4 2250 70 26 141 74 73 1-90 freeway 3544 3 12 4 2250 70 26 142 74 75 1-80 freeway 5340 3 12 4 2250 70 27 143 75 74 1-90 freeway 5339 3 12 4 2250 70 27 144 75 76 1-80 freeway 7306 3 12 4 2250 70 27 145 76 75 1-90 freeway 7306 3 12 4 2250 70 27 146 76 77 1-80 freeway 5861 3 12 4 2250 70 28 147 77 76 1-90 freeway 5861 3 12 4 2250 70 28 148 77 78 1-80 freeway 9488 3 12 4 2250 70 31 149 78 77 1-90 freeway 9488 3 12 4 2250 70 31 150 78 79 1-80 freeway 7712 3 12 4 2250 70 31 151 79 78 1-90 freeway 7713 3 12 4 2250 70 31 Exit Link 79 8079 1-80 freeway 2599 3 12 4 2250 70 31 152 80 81 SR 2 freeway 2786 2 12 4 2250 70 25 Exit Link 80 8080 SR 2 freeway 1057 2 12 4 2250 70 25 153 81 80 SR 2 freeway 2797 2 12 4 2250 70 25 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-42 KLD Engineering, P.C.Rev. 2 154 81 82 SIR 2 freeway 11739 2 12 4 2250 70O1 25 155 82 81 SR 2 freeway 11739 2 12 4 2250 70 25 156 82 86 SR 2 freeway 1001 2 12 4 2250 70 18 157 83 84 SR 269 collector 1008 1 12 4 1700 40 18 158 84 85 SR 269 off-ramp to SR 2 freeway 677 1 12 4 1125 25 18 SR 2 on-ramp from SR freeway 159 85 87 269 ramp 705 1 12 4 1700 40 18 160 86 82 SR 2 freeway 997 2 12 4 2250 70 18 161 86 87 SR 2 freeway 1026 2 12 4 2250 70 18 162 87 86 SR 2 freeway 1026 2 12 4 2250 70 18 163 87 88 SR 2 freeway 1217 2 12 4 2250 70 18 164 88 87 SR 2 freeway 1209 2 12 4 2250 70 18 165 88 89 SR 2 freeway 3077 2 12 4 2250 70 18 166 89 88 SR 2 freeway 3077 2 12 4 2250 70 18 167 89 90 SR 2 freeway 1976 2 12 4 2250 70 18 168 90 89 SR 2 freeway 1976 2 12 4 2250 70 18 169 90 95 SR 2 freeway 6333 2 12 4 2250 70 17 170 91 92 SR 53 collector 1285 1 12 4 1700 40 17 freeway 171 92 93 SR 53 off-ramp to SR 2 ramp 845 1 12 4 1700 40 18 freeway 172 93 89 SR 2 on-ramp from SR 53 ramp 647 1 12 4 1700 40 18 173 94 95 SR 2 freeway 4004 2 12 4 2250 70 17 174 94 96 SR 2 freeway 2665 2 12 4 2250 70 14 175 95 90 SR 2 freeway 6333 2 12 4 2250 70 17 176 95 94 SR 2 freeway 4004 2 12 4 2250 70 17 177 96 94 SR 2 freeway 2676 2 12 4 2250 70 14 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-43 KLD Engineering, P.C.Rev. 2 178 96 100 1SIR 2 freeway 4836 2 12 4 2250 70O1 14 SR 2 on-ramp from SR freeway 179 97 99 163 ramp 672 1 12 4 1700 40 14 SR 2 on-ramp from SR freeway 180 98 97 163 ramp 1285 1 12 4 1700 40 14 SR 2 on-ramp from SR freeway 181 99 94 163 ramp 595 1 12 4 1700 40 14 182 100 96 SR 2 freeway 4836 2 12 4 2250 70 14 183 100 101 SR 2 freeway 2506 2 12 4 2250 70 14 freeway 184 101 100 SR 2 ramp 2505 2 12 4 2250 70 14 185 101 102 SR 2 freeway 9496 2 12 4 2250 70 14 freeway 186 102 101 SR 2 ramp 9496 2 12 4 2250 70 14 187 102 103 SR 2 freeway 1500 2 12 4 2250 70 13 188 103 102 SR 2 freeway 1499 2 12 4 2250 70 13 189 103 104 SR 2 freeway 857 2 12 4 2250 70 13 190 104 103 SR 2 freeway 857 2 12 4 2250 70 13 191 104 105 SR 2 freeway 9565 2 12 4 2250 70 12 freeway 192 104 108 SR 2 off-ramp to SR 53 ramp 436 1 12 4 1125 25 13 193 105 104 SR 2 freeway 9565 2 12 4 2250 70 12 194 105 110 SR 2 freeway 5220 2 12 4 2250 70 12 195 106 25 W Fremont Rd collector 2758 1 12 4 1700 60 13 196 106 298 W Fremont Rd collector 2186 1 12 4 1750 35 13 freeway 197 107 25 SR 53 on-ramp from SR 2 ramp 357 1 12 4 1125 25 13 198 108 107 SR 53 on-ramp from SR 2 freeway 454 1 12 4 1125 25 13 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-44 KLD Engineering, P.C.Rev. 2 ramp SR 2 on-ramp from SR freeway 199 109 105 163 ramp 1102 1 12 4 1700 40 12 200 109 403 SR 163 collector 2303 1 12 4 1700 55 12 201 110 105 SR 2 freeway 5220 2 12 8 2250 70 12 minor 202 110 111 SR 2 arterial 2527 2 12 4 1900 60 12 minor 203 111 110 SR 2 arterial 2527 2 12 4 1900 60 12 minor 204 111 112 SR 2 arterial 3420 2 12 4 1900 60 12 205 111 405 SR 358 collector 4872 1 12 4 1700 50 12 minor 206 112 111 SR 2 arterial 3420 2 12 4 1900 60 12 minor 207 112 120 SR 2 arterial 1507 2 12 4 1900 60 12 minor 208 113 114 SR 2 arterial 2656 2 12 4 1900 60 12 minor 209 113 120 SR 2 arterial 1660 2 12 4 1900 60 12 minor 210 114 113 SR 2 arterial 2656 2 12 4 1900 60 12 minor 211 114 123 SR 2 arterial 1221 2 12 4 1900 60 12 212 115 118 SR 2 collector 4359 1 12 4 1700 60 6 213 115 123 SR 2 collector 6466 1 12 4 1700 60 12 214 116 117 SR 2 collector 2887 1 12 4 1700 60 6 215 116 126 SR 2 collector 2159 1 12 4 1700 60 6 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-45 KLD Engineering, P.C.Rev. 2 216 117 116 SR 2 collector 2887 1 12 4 1700 60 6 217 117 119 SR 2 collector 3449 1 12 4 1700 45 6 218 118 115 SR 2 collector 4359 1 12 4 1700 60 6 219 118 126 SR 2 collector 3523 1 12 4 1700 60 6 220 119 117 SR 2 collector 3449 1 12 4 1700 45 6 221 119 128 SR 2 collector 882 1 12 4 1700 50 6 minor 222 120 112 SR 2 arterial 1507 2 12 4 1900 60 12 minor 223 120 113 SR 2 arterial 1660 2 12 4 1900 60 12 224 121 111 Niagra collector 2472 1 12 4 1575 35 12 225 122 120 Ave H collector 1309 1 12 4 1575 35 12 minor 226 123 114 SR 2 arterial 1221 2 12 4 1900 60 12 227 123 115 SR 2 collector 6466 1 12 4 1700 60 12 228 124 118 Township Hwy 224 collector 756 1 12 4 1375 35 6 229 125 124 Township Hwy 224 collector 2722 1 12 4 1575 35 6 230 126 116 SR 2 collector 2159 1 12 4 1700 60 6 231 126 118 SR 2 collector 3523 1 12 4 1700 60 6 232 127 126 Township Rd 104 collector 2893 1 12 4 1575 35 6 233 128 119 SR 2 collector 882 1 12 4 1700 45 6 234 128 130 SR 2 collector 442 1 12 4 1700 50 6 235 129 128 Plant Access Rd collector 1531 1 12 4 1575 35 6 236 130 128 SR 2 collector 442 1 12 4 1700 50 6 237 130 131 SR 2 collector 2213 1 12 4 1700 40 6 238 131 130 SR 2 collector 2220 1 12 4 1700 40 6 239 131 132 SR 2 collector 1298 1 12 4 1700 50 6 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-46 KLD Engineering, P.C.Rev. 2 240 132 131 1SR 2 collector 1298 1 12 4 1700 50 6 241 132 134 SR 2 collector 3473 1 12 4 1700 60 6 local 242 133 132 N Russell Rd roadway 2144 1 12 4 1350 35 6 243 134 132 SR 2 collector 3473 1 12 4 1700 50 6 244 134 136 SR 2 collector 7130 1 12 4 1700 60 6 245 135 134 N Humphrey Rd collector 2607 1 12 4 1575 35 6 246 136 134 SR 2 collector 7130 1 12 4 1700 60 6 247 136 141 SR 2 collector 10179 1 12 4 1700 60 5 248 137 141 SR 2 collector 2689 1 12 4 1700 60 5 249 137 142 SR 2 collector 2615 1 12 4 1700 60 5 local 250 138 137 Park Rd 1 roadway 2566 1 12 4 675 15 5 local 251 139 138 Park Rd 1 roadway 2032 1 12 4 675 15 5 local 252 140 139 Park Rd 1 roadway 1187 1 12 4 675 15 5 253 141 136 SR 2 collector 10179 1 12 4 1700 60 5 254 141 137 SR 2 collector 2689 1 12 4 1700 60 5 255 142 137 SR 2 collector 2615 1 12 4 1700 60 5 256 142 143 SR 2 collector 5437 1 12 4 1700 60 5 257 143 142 SR 2 collector 5437 1 12 4 1700 60 5 258 143 145 SR 2 collector 9289 1 12 4 1700 60 4 259 143 174 SR 590 collector 5110 1 12 4 1700 60 5 Ottawa National Wildlife local 260 144 142 Refuge roadway 742 1 12 4 675 15 5 261 145 143 SR 2 collector 9289 1 12 4 1700 60 5 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-47 KLD Engineering, P.C.Rev. 2 262 145 146 SR 2 collector 1707 1 12 4 1700 40 4 local 263 145 171 SR 579 roadway 245 1 12 4 1125 25 4 local 264 146 145 SR 2 roadway 1683 1 12 4 1125 40 4 265 146 147 SR 2 collector 10377 1 12 4 1700 60 2 266 147 146 SR 2 collector 10377 1 12 4 1700 60 2 267 147 148 SR 2 collector 1937 1 12 4 1700 s0 2 268 148 147 SR 2 collector 1966 1 12 4 1700 50 2 269 148 149 SR 2 collector 2394 1 12 4 1700 60 2 270 149 148 SR 2 collector 2394 1 12 4 1700 60 2 271 149 154 SR 2 collector 5326 1 12 4 1700 60 2 272 150 151 Co Rd 209 collector 805 1 12 4 1575 35 2 273 151 153 Corduroy Rd collector 5250 1 12 4 1700 60 2 274 151 452 Co Rd 209 collector 1357 1 12 4 1700 60 2 275 152 153 Anchor Point Rd collector 2051 1 12 4 1700 60 2 276 153 453 N Teachout Rd collector 2702 1 12 4 1700 60 2 277 153 468 Corduroy Rd collector 10606 1 12 4 1700 60 2 278 154 149 SR 2 collector 5326 1 12 4 1700 60 2 279 154 155 SR 2 collector 10742 1 12 4 1700 60 2 minor 280 155 1 SR 2 arterial 10544 2 12 4 1750 60 1 281 155 154 SR 2 collector 10742 1 12 4 1700 60 2 minor 282 156 1 SR 2 arterial 10664 2 12 4 1750 60 1 minor 283 156 472 SR 2 arterial 5172 2 12 4 1900 60 1 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-48 KLD Engineering, P.C.Rev. 2 284 157 11 S Curtice Rd collector 3684 1 12 4 1750 55 I 285 158 157 S Curtice Rd collector 1581 1 12 4 1575 35 1 286 158 159 County Rd 202 collector 1577 1 12 4 1575 35 1 287 159 158 County Rd 202 collector 1577 1 12 4 1575 35 1 288 159 160 Front St collector 907 1 12 4 1575 35 3 local 289 160 161 N Wildacre Rd roadway 649 1 12 4 675 15 3 290 161 162 N Wildacre Rd collector 1243 1 12 4 1575 35 3 291 162 163 N Wildacre Rd collector 3605 1 12 4 1700 40 3 292 163 164 SR 579 collector 1201 1 12 4 1700 50 3 293 164 165 SR 579 collector 2400 1 12 4 1700 50 3 294 165 166 SR 579 collector 4384 1 12 4 1700 50 3 Exit Link 166 8166 SR 579 collector 3504 1 12 4 1700 50 3 295 167 163 SR 579 collector 2371 1 12 4 1700 50 3 296 168 167 SR 579 collector 4406 1 12 4 1700 50 3 297 169 168 SR 579 collector 2502 1 12 4 1700 40 4 298 170 169 SR 579 collector 9295 1 12 4 1700 60 4 299 171 145 SR 579 collector 245 1 12 4 1700 60 4 local 300 171 172 SR 579 roadway 852 1 12 4 1125 25 4 local 301 172 171 SR 579 roadway 852 1 12 4 1125 25 4 302 172 173 SR 579 collector 484 1 12 4 1700 60 4 303 173 170 SR 579 collector 10588 1 12 4 1700 60 4 304 173 172 SR 579 collector 484 1 12 4 1700 60 4 305 174 143 SR 590 collector 5110 1 12 4 1700 60 5 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-49 KLD Engineering, P.C.Rev. 2 306 174 175 1SR 590 collector 12477 I 12 4 1700 55 5 307 175 174 SR 590 collector 12477 1 12 4 1700 60 5 local 308 175 176 SR 590 roadway 706 1 12 4 1350 30 10 local 309 176 175 SR 590 roadway 706 1 12 4 1350 30 10 310 176 177 SR 590 collector 992 1 12 4 1700 55 10 311 177 176 SR 590 collector 992 1 12 4 1700 55 10 312 177 178 SR 590 collector 5189 1 12 4 1700 60 10 313 178 179 SR 590 collector 784 1 12 4 1575 35 10 314 179 180 SR 590 collector 1387 1 12 4 1700 60 10 315 180 181 SR 590 collector 5310 1 12 4 1700 60 10 316 181 182 SR 590 collector 8335 1 12 4 1700 60 10 317 181 222 SR 163 collector 10619 1 12 4 1700 60 9 318 182 183 SR 590 collector 855 1 12 4 1700 50 10 319 182 253 SR 105 collector 1641 1 12 4 1700 50 10 320 183 184 SR 590 collector 4122 1 12 4 1700 60 22 minor 321 184 487 SR 590 arterial 2578 1 12 4 1700 60 22 322 185 186 SR 590 collector 5439 1 12 4 1700 60 22 323 186 187 SR 590 collector 2448 1 12 4 1700 50 22 324 187 188 SR 590 collector 668 1 12 4 1575 35 26 local 325 188 189 SR 590 roadway 658 1 12 4 900 20 26 326 189 55 SR 590 collector 1677 1 12 4 1700 50 26 327 190 173 County Rd 19 collector 5319 1 12 4 1700 60 4 328 191 190 County Rd 19 collector 6231 1 12 4 1700 60 4 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-SO KLD Engineering, P.C.Rev. 2 329 192 191 County Rd 19 collector 674 1 12 4 1700 40 4 330 193 192 County Rd 19 collector 9711 1 12 4 1700 60 4 local 331 194 193 N Graytown Rd roadway 298 1 12 4 675 15 9 332 195 61 SR 51 collector 1213 1 12 4 1700 45 21 local 333 196 195 SR 51 roadway 476 1 12 4 1125 25 21 local 334 197 196 SR 51 roadway 471 1 12 4 1125 25 21 local 335 198 197 SR 51 roadway 1342 1 12 4 1125 25 21 local 336 198 199 SR 51 roadway 1180 1 12 4 1125 25 21 337 199 198 SR 51 collector 1180 1 12 4 1750 25 21 338 199 205 SR 51 collector 3656 1 12 4 1700 60 21 339 200 198 Toledo St collector 1770 1 12 4 1750 25 21 340 201 198 Rice St collector 743 1 12 4 1750 25 21 341 202 203 SR 51 collector 3682 1 12 4 1700 60 9 342 203 204 SR 51 collector 1481 1 12 4 1750 60 9 343 204 206 SR 51 collector 5085 1 12 4 1700 60 8 344 204 207 SR 163 collector 3438 1 12 4 1700 55 8 345 205 202 SR 51 collector 8740 1 12 4 1700 60 9 346 206 209 SR 51 collector 3141 1 12 4 1750 60 8 347 207 218 SR 163 collector 2680 1 12 4 1750 40 8 348 208 204 SR 163 collector 4539 1 12 4 1750 60 9 349 209 210 SR 51 collector 7123 1 12 4 1700 60 8 350 209 215 Main St collector 1578 1 12 4 1575 35 8 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-51 KLD Engineering, P.C.Rev. 2 351 210 211 SR 51 collector 564 1 121700 60 8 352 211 212 SR 51 collector 2975 1 12 4 1700 60 8 Exit Link 212 8212 SR 51 collector 836 1 12 4 1700 60 8 353 213 209 County Rd 51 collector 3132 1 12 4 1750 55 8 354 214 213 County Rd 51 collector 1936 1 12 4 1700 60 8 355 215 209 Main St collector 1578 1 12 4 1750 35 8 356 215 216 Main St collector 3026 1 12 4 1750 35 8 357 216 215 Main St collector 3026 1 12 4 1575 35 8 358 216 218 Main St collector 1032 1 12 4 1750 35 8 local 359 217 216 E 6th St roadway 387 1 12 4 1750 25 8 360 218 216 Main St collector 1032 1 12 4 1750 35 8 361 218 219 SR 163 collector 2796 1 12 4 1700 40 8 362 218 431 Main St collector 1017 1 12 4 1575 35 8 363 219 220 SR 163 collector 2500 1 12 4 1700 50 8 Exit Link 220 8220 SR 163 collector 1185 1 12 4 1700 60 8 364 221 208 SR 163 collector 10912 1 12 4 1700 60 9 365 222 181 SR 163 collector 10619 1 12 4 1700 60 9 366 222 221 SR 163 collector 5218 1 12 4 1700 60 9 367 222 246 Township Hwy 19 collector 7980 1 12 4 1700 50 9 368 223 181 SR 163 collector 10581 1 12 4 1700 60 10 369 223 224 SR 163 collector 2684 1 12 4 1575 35 10 370 223 234 S Benton Carroll Rd collector 5788 1 12 4 1700 60 10 371 224 223 SR 163 collector 2684 1 12 4 1700 45 10 372 224 225 SR 163 collector 2963 1 12 4 1575 35 10 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-52 KLD Engineering, P.C.Rev. 2 373 225 224 SR 163 collector 2963 1 12 4 1700 45 10 374 225 226 SR 163 collector 1157 1 12 4 1575 35 11 local 375 226 225 SR 163 roadway 1157 1 12 4 1350 30 11 376 226 227 SR 163 collector 1874 1 12 4 1575 35 11 377 227 226 SR 163 collector 1874 1 12 4 1575 35 11 378 227 228 SR 163 collector 942 1 12 4 1750 35 11 local 379 228 227 SR 163 roadway 942 1 12 4 1350 30 11 380 228 230 SR 105 collector 402 1 12 4 1575 35 11 local 381 228 231 SR 163 roadway 831 1 12 4 1125 25 11 local 382 229 227 Benton St roadway 1315 1 12 4 1125 25 11 383 230 232 SR 105 collector 2767 1 12 4 1700 60 11 local 384 231 228 SR 163 roadway 831 1 12 4 1750 25 11 local 385 231 256 SR 163 roadway 354 1 12 4 900 20 11 386 232 233 SR 105 collector 3781 1 12 4 1700 60 10 387 233 234 SR 105 collector 1757 1 12 4 1700 60 10 388 234 223 S Benton Carroll Rd collector 5788 1 12 4 1700 60 10 389 234 235 SR 105 collector 5259 1 12 4 1700 60 10 390 235 255 SR 105 collector 1178 1 12 4 1700 60 10 391 236 223 Benton Carroll Rd collector 3908 1 12 4 1700 60 10 392 237 236 Benton Carroll Rd collector 332 1 12 4 1700 40 10 393 238 237 Benton Carroll Rd collector 3261 1 12 4 1700 60 10 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-53 KLD Engineering, P.C.Rev. 2 Up- Don oSauain Fe 394 239 238 Benton Carroll Rd collector 485 1 12 4 1700 0 10 395 240 456 N Benton Carroll Rd collector 1577 1 24 1700 605 396 241 141 N Benton Carroll Rd collector 5288 1 24 1700 605 397 241 240 N Benton Carroll Rd collector 8889 1 12 4 1700 60 5 398 242 241 Township Hwy 91 collector 1374 1 12 4 1700 40 5 399 243 194 N Graytown Rd collector 573 1 12 4 1575 35 9 400 243 245 N Graytown Rd collector 1162 1 12 4 1700 60 9 local 401 244 243 Maple roadway 352 1 12 4 900 20 9 402 245 222 N Graytown Rd collector 7926 1 12 4 1700 60 9 403 246 450 SR 105 collector 2806 1 12 4 1700 50 9 404 247 246 SR 105 collector 621 1 12 4 1700 60 9 405 248 247 SR 105 collector 1207 1 12 4 1700 50 9 406 249 248 SR 105 collector 1471 1 12 4 1700 50 9 407 250 249 SR 105 collector 1725 1 12 4 1700 55 10 408 251 250 SR 105 collector 1372 1 12 4 1700 55 10 409 252 251 SR 105 collector 765 1 12 4 1700 50 10 410 253 252 SR 105 collector 1934 1 12 4 1700 50 10 411 254 182 SR 105 collector 2617 1 12 4 1700 60 10 412 255 254 SR 105 collector 1812 1 12 4 1700 60 10 local 413 256 231 SR 163 roadway 354 1 12 4 900 20 11 414 256 258 SR 163 collector 480 1 12 4 1750 25 11 415 257 414 SR 163 collector 2049 1 12 4 1700 45 11 local 416 258 256 SR 163 roadway 480 1 12 4 1125 25 11 417 258 260 SR 163 collector 684 1 12 4 1750 2511 Davis-Besse Nuclear Power Station K-54 KLD Engineering, P.C.Evacuation Time Estimate Rev. 2 418 259 258 1 N Church St collector 395 1 12 4 1750 25 11 419 260 258 SR 163 collector 684 1 12 4 1750 25 11 420 260 261 SR 19 collector 544 1 12 4 1575 35 11 local 421 260 262 SR 163 roadway 1343 1 12 4 1125 25 11 422 261 264 SR 19 collector 1196 1 12 4 1700 55 11 423 262 257 SR 163 collector 2045 1 12 4 1575 35 11 424 262 260 SR 163 collector 1342 1 12 4 1750 25 11 425 263 260 SR 19 collector 840 1 12 4 1750 25 11 426 264 473 SR 19 collector 2005 1 10 4 1700 55 11 427 265 266 SR 19 collector 5235 1 12 4 1700 55 23 428 266 267 SR 19 collector 2653 1 12 4 1700 55 23 429 267 268 SR 19 collector 2650 1 12 4 1700 55 23 430 268 269 SR 19 collector 2449 1 12 4 1700 55 23 local 431 269 270 SR 19 roadway 321 1 12 4 900 20 23 432 270 271 SR 19 collector 2196 1 12 4 1700 45 23 local 433 271 272 SR 19 roadway 269 1 12 4 900 20 23 434 272 273 SR 19 collector 2520 1 12 4 1700 55 23 435 273 274 SR 19 collector 4979 1 12 4 1700 55 23 436 274 277 SR 19 collector 217 1 12 4 1700 45 23 437 275 280 SR 19 collector 694 1 12 4 1350 30 27 438 276 281 SR 19 collector 6478 1 12 4 1700 55 27 439 277 278 SR 19 collector 347 1 12 4 1700 45 23 440 278 279 SR 19 collector 267 1 12 4 1700 45 23 441 279 275 SR 19 collector 2913 1 12 4 1700 55 23 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-55 KILD Engineering, P.C.Rev. 2 442 280 276 SR 19 collector 6268 1 12 4 1700 55 27 443 281 282 SR 19 collector 1047 1 12 4 1700 45 29 444 282 283 SR 19 collector 1927 1 12 4 1700 55 29 minor 445 283 284 SR 19 arterial 720 2 12 4 1750 55 29 minor 446 284 39 SR 19 arterial 1098 2 12 4 1750 55 29 Exit minor Link 286 8286 SR 19 arterial 290 2 12 4 1700 55 29 freeway 447 287 33 US-6 on-ramp from SR 19 ramp 606 1 12 4 1700 40 29 448 287 40 SR 19 on-ramp from US-6 collector 583 1 12 4 1750 40 29 449 288 284 Dickinson St collector 710 1 12 4 1750 35 29 450 289 3 Sean St collector 590 1 12 4 1750 35 30 451 290 26 Co Rd 584 collector 351 1 12 4 1750 35 28 local 452 291 292 SR 53 off-ramp to 1-90 roadway 479 1 12 4 1125 25 28 453 292 293 SR 53 off-ramp to 1-90 collector 1341 1 12 4 1700 40 28 454 293 294 SR 53 off-ramp to 1-90 collector 974 1 12 4 1700 40 28 freeway 455 294 76 1-90 on-ramp from SR53 ramp 941 1 12 4 1700 40 28 456 294 295 SR 53 off-ramp to 1-80 collector 981 1 12 4 1700 40 28 local 457 295 296 1-80 on-ramp from SR 53 roadway 519 1 12 4 1125 25 28 freeway 458 296 76 1-80 on-ramp from SR 53 ramp 409 1 12 4 1125 2528 459 297 4 Fangboner Rd collector 1101 1 12 4 1750 25 30 460 298 106 W Fremont Rd collector 2186 1 12 4 1575 35 13 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-56 KLD Engineering, P.C.Rev. 2 461 298 300 1Fremont Rd collector 266 1 12 41 1575 35 13 1 462 299 298 Kentucky St collector 207 1 12 4 1750 35 13 463 300 298 Fremont Rd collector 266 1 12 4 1750 35 13 local 464 300 301 Lay Dr roadway 401 1 12 4 1125 25 13 local 465 300 318 Fremont Rd roadway 1783 1 12 4 1125 25 13 local 466 301 300 Lay Dr roadway 401 1 12 4 1125 25 13 local 467 301 302 W 6th St roadway 1067 1 12 4 1125 25 13 local 468 302 301 W 6th St roadway 1067 1 12 4 1125 25 13 local 469 302 303 W 6th St roadway 2019 1 12 4 1125 25 14 local 470 303 302 W 6th St roadway 2019 1 12 4 1125 25 14 local 471 303 305 Madison St roadway 993 1 12 4 1125 25 14 472 303 306 E 6th St collector 505 1 12 4 1750 25 14 local 473 304 303 Madison St roadway 1041 1 12 4 1125 25 14 474 305 314 Madison St collector 556 1 12 4 1750 25 14 local 475 306 303 E 6th St roadway 505 1 12 4 1125 25 14 476 306 308 Jefferson St collector 993 1 12 4 1750 25 14 477 307 306 Jefferson St collector 1380 1 12 4 1750 25 14 local 478 308 305 E4th St roadway 501 1 12 4 1125 25 14 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-57 KLD Engineering, P.C.Rev. 2 479 308 311 1 Jefferson St collector 1062 1 12 4 1750 1 25 14 480 309 306 E 6th St collector 1422 1 12 4 1750 25 14 local 481 309 310 Fulton St roadway 973 1 12 4 1125 25 14 local 482 309 457 Fulton St roadway 4486 1 10 4 1350 30 14 483 310 308 E 4th St collector 1431 1 12 4 1750 25 14 local 484 310 326 Fulton St roadway 1664 1 12 4 1125 25 14 485 311 312 Jefferson St collector 493 1 12 4 1750 25 14 local 486 311 313 E 2nd St roadway 526 1 12 4 1125 25 14 local 487 312 315 SR 163 roadway 502 1 12 4 1125 25 14 minor 488 312 316 SR 163 arterial 543 2 12 4 1750 30 14 489 313 311 E 2nd St collector 526 1 12 4 1750 25 14 490 313 314 Madison St collector 511 1 12 4 1750 25 14 491 313 316 Madison St collector 494 1 12 4 1750 25 14 local 492 314 313 Madison St roadway 511 1 12 4 1125 25 14 local 493 314 317 W 3rd St roadway 1482 1 12 4 1125 25 14 minor 494 315 312 SR 163 arterial 502 2 12 4 1750 30 14 minor 495 315 326 SR 163 arterial 953 2 12 4 1900 35 14 minor 496 316 312 SR 163 arterial 543 2 12 4 1750 30 14 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-58 KLD Engineering, P.C.Rev. 2 iocai roadway 497 316 313 1 Madison St 494 1 12 4 1125 25 14 minor 498 316 319 SR 163 arterial 489 2 12 4 1125 25 14 499 317 314 W 3rd St collector 1482 1 12 4 1750 25 14 local 500 317 318 Harrison St roadway 320 1 12 4 1125 25 13 local 501 318 300 Fremont Rd roadway 1783 1 12 4 1125 25 13 local 502 318 317 Harrison St roadway 320 1 12 4 1125 25 13 minor 503 319 316 SR 163 arterial 489 2 12 4 1750 25 14 minor 504 319 320 SR 163 arterial 971 2 12 4 1125 25 14 minor 505 320 319 SR 163 arterial 971 2 12 4 1125 25 14 minor 506 320 321 SR 163 arterial 614 2 12 4 1350 30 14 minor 507 321 320 SR 163 arterial 610 2 12 4 1350 30 14 minor 508 321 322 SR 163 arterial 937 2 12 4 1700 40 14 minor 509 322 321 SR 163 arterial 937 12 4 1700 40 14 510 322 323 SR 163 collector 548 1 12 4 1700 40 13 511 323 322 SR 163 collector 548 1 12 4 1700 40 13 512 323 324 SR 163 collector 2592 1 12 4 1700 40 13 513 324 323 SR 163 collector 2592 1 12 4 1700 40 13 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-59 KLD Engineering, P.C.Rev. 2 514 324 398 1SIR 163 collector 1041 1 12 4 1700 45 13 local 515 325 319 W Perry St roadway 496 1 12 4 1125 25 14 minor 516 326 315 SR 163 arterial 953 2 12 4 1700 35 14 minor 517 326 327 SR 163 arterial 1213 2 12 4 1700 35 14 minor 518 327 326 SR 163 arterial 1213 2 12 4 1700 35 14 minor 519 327 328 SR 163 arterial 1442 2 12 4 1700 35 14 minor 520 328 327 SR 163 arterial 1442 2 12 4 1700 35 14 minor 521 328 329 SR 163 arterial 835 2 12 4 1750 35 14 minor 522 329 328 SR 163 arterial 835 2 12 4 1700 35 14 minor 523 329 330 SR 163 arterial 1142 2 12 4 1700 35 14 minor 524 330 329 SR 163 arterial 1142 2 12 4 1750 35 14 minor 525 330 331 SR 163 arterial 1120 2 12 4 1750 35 14 minor 526 331 330 SR 163 arterial 1120 2 12 4 1700 35 14 minor 527 331 334 SR 163 arterial 822 2 12 4 1700 35 14 528 332 329 Maple St collector 899 1 12 4 1750 25 14 529 333 331 Buckeye Blvd collector 1844 1 12 4 1750 3 14 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-60 KLD Engineering, P.C.Rev. 2 p D o Srat Strea Stea Ro.wa of Lan S hole Flo Flo Ma minor 530 334 331 SR 163 arterial 822 2 12 4 1750 35 14 minor 531 334 335 SR 163 arterial 223 2 12 4 1700 35 14 local 532 334 336 SR 163 off-ramp to SR 2 roadway 504 1 12 4 1125 25 14 533 335 98 SR 163 off-ramp to SR 2 collector 866 1 12 4 1700 40 14 minor 534 335 334 SR 163 arterial 223 2 12 4 1700 35 14 535 335 338 SR 163 collector 536 1 12 4 1700 45 14 local 536 336 337 SR 163 off-ramp to SR 2 roadway 315 1 12 4 1125 25 14 537 337 98 SR 163 off-ramp to SR 2 collector 950 1 12 4 1700 40 14 538 338 335 SR 163 collector 536 1 12 4 1700 45 14 539 338 339 SR 163 collector 777 1 12 4 1700 45 14 540 339 338 SR 163 collector 777 1 12 4 1700 45 14 541 339 340 SR 163 collector 394 1 12 4 1700 45 14 542 340 339 SR 163 collector 394 1 12 4 1700 45 14 543 340 341 SR 163 collector 182 1 12 4 1750 45 14 544 341 340 SR 163 collector 182 1 12 4 1700 45 14 545 341 343 SR 163 collector 393 1 12 4 1700 45 14 546 342 340 E Sand Rd collector 284 1 12 4 1575 35 14 547 342 341 E Sand Rd collector 178 1 12 4 1750 35 14 548 343 341 SR 163 collector 393 1 12 4 1750 45 14 549 343 344 SR 163 collector 1204 1 12 4 1700 45 17 550 344 343 SR 163 collector 1204 1 12 4 1700 45 17 551 344 345 SR 163 collector 2604 1 12 4 1700 60 17 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-61 KLD Engineering, P.C.Rev. 2 552 345 344 SR 163 collector 2604 1 12 4 1700 60 17 553 345 346 SR 163 collector 1245 1 12 4 1700 60 17 554 346 345 SR 163 collector 1245 1 12 4 1700 60 17 555 346 347 SR 163 collector 2213 1 12 4 1700 60 17 556 347 346 SR 163 collector 2213 1 12 4 1700 60 17 557 347 348 SR 163 collector 2568 1 12 4 1700 60 17 558 348 347 SR 163 collector 2568 1 12 4 1700 60 17 559 348 349 SR 163 collector 1002 1 12 4 1700 60 17 560 349 348 SR 163 collector 1002 1 12 4 1700 60 17 561 349 351 SR 163 collector 1160 1 12 4 1750 60 17 local 562 350 349 Driveway to Walmart roadway 379 1 12 4 1125 25 17 563 351 91 SR 53 collector 5684 1 12 4 1750 60 17 564 351 349 SR 163 collector 1160 1 12 4 1700 60 17 565 351 353 SR 163 collector 731 1 12 4 1700 60 18 566 352 351 SR 53 collector 1330 1 12 4 1750 40 15 567 353 351 SR 163 collector 731 1 12 4 1750 60 18 568 353 354 SR 163 collector 1027 1 12 4 1700 55 16 569 354 353 SR 163 collector 1025 1 12 4 1700 55 16 570 354 355 SR 163 collector 877 1 12 4 1700 55 16 571 355 354 SR 163 collector 877 1 12 4 1700 55 16 572 355 356 SR 163 collector 1606 1 12 4 1700 55 16 573 356 355 SR 163 collector 1606 1 12 4 1700 55 16 574 356 357 SR 163 collector 3462 1 12 4 1700 55 16 575 357 356 SR 163 collector 3462 1 12 4 1700 55 16 576 357 358 SR 163 collector 852 1 12 4 1700 55 16 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-62 KLD Engineering, P.C.Rev. 2 minor arterial 577 358 357 1 SR 163 852 2 12 4 1900 55 16 578 358 361 SR 269 collector 6706 1 12 4 1700 60 16 minor 579 359 358 SR 163 arterial 2211 2 12 4 1700 60 16 minor 580 361 358 SR 269 arterial 6706 2 12 4 1700 60 16 581 361 362 SR 269 collector 2108 1 12 4 1700 60 18 582 362 363 SR 269 collector 1184 1 12 4 1700 45 18 583 363 83 SR 269 collector 1680 1 12 4 1700 60 18 minor 584 364 359 SR 163 arterial 2312 2 12 4 1700 60 16 585 365 361 Port Clinton collector 2248 1 12 4 1700 40 18 minor 586 366 359 Township Hwy 139 arterial 1808 2 12 4 1750 55 16 587 367 366 Township Hwy 139 collector 1383 1 12 4 1700 50 16 588 368 367 Township Hwy 139 collector 1835 1 12 4 1700 50 16 589 369 368 Township Hwy 139 collector 2028 1 12 4 1700 40 16 590 370 369 Township Hwy 139 collector 1685 1 12 4 1700 40 16 591 371 91 E State Rd collector 2291 1 12 4 1750 40 18 592 372 371 Township Hwy 35 collector 2945 1 12 4 1700 40 18 593 373 352 SR 53 collector 1717 1 12 4 1700 40 16 594 374 373 SR 53 collector 2674 1 12 4 1700 55 16 595 375 374 SR 53 collector 4169 1 12 4 1700 55 16 596 376 375 SR 53 collector 2595 1 12 4 1700 55 16 597 377 376 SR 53 collector 3133 1 12 4 1700 55 7 598 378 377 SR 53 collector 4151 1 12 4 1700 55 7 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-63 KLD Engineering, P.C.Rev. 2 599 379 378 SR 53 collector 4585 1 12 4 1700 55 7 local 600 380 379 SR 53 roadway 383 1 12 4 1350 30 7 local 601 381 380 SR 53 roadway 855 1 12 4 1350 30 7 local 602 381 385 Township Hwy 1057 roadway 980 1 12 4 1350 30 7 local 603 382 381 N Crogan St roadway 412 1 12 4 1350 30 7 local 604 383 382 Water St roadway 464 1 12 4 1350 30 7 local 605 383 384 Water St roadway 501 1 12 4 1350 30 7 local 606 384 385 NW Catawba Rd roadway 419 1 12 4 1350 30 7 local 607 385 381 Township Hwy 1057 roadway 980 1 12 4 1350 30 7 local 608 385 386 NW Catawba Rd roadway 1683 1 12 4 1350 30 7 609 386 387 NW Catawba Rd collector 1620 1 12 4 1700 45 7 610 387 388 NW Catawba Rd collector 2187 1 12 4 1700 45 7 611 388 389 NW Catawba Rd collector 2227 1 12 4 1700 45 7 612 389 390 NW Catawba Rd collector 3516 1 12 4 1700 55 7 613 390 391 NW Catawba Rd collector 7536 1 12 4 1700 55 16 614 391 392 E Sand Rd collector 385 1 12 4 1700 40 15 615 392 393 E Sand Rd collector 1124 1 12 4 1700 55 15 616 393 394 E Sand Rd collector 1313 1 12 4 1575 35 15 617 394 395 E Sand Rd collector 977 1 12 4 1700 45 15 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-64 KLD Engineering, P.C.Rev. 2 618 395 396 E Sand Rd collector 2813 1 12 4 1700 45 15 619 396 397 E Sand Rd collector 6087 1 12 4 1700 45 15 620 397 342 E Sand Rd collector 1529 1 12 4 1700 45 14 621 398 324 SR 163 collector 1041 1 12 4 1700 45 13 622 398 399 SR 163 collector 1920 1 12 4 1700 45 13 623 399 398 SR 163 collector 1920 1 12 4 1700 45 13 624 399 400 SR 163 collector 3093 1 12 4 1700 45 13 625 400 399 SR 163 collector 3093 1 12 4 1700 45 13 626 400 401 SR 163 collector 3374 1 12 4 1700 60 12 627 401 400 SR 163 collector 3374 1 12 4 1700 60 12 628 401 402 SR 163 collector 568 1 12 4 1700 40 12 629 402 401 SR 163 collector 568 1 12 4 1700 40 12 local 630 402 403 SR 163 roadway 330 1 12 4 900 20 12 631 403 109 SR 163 collector 2303 1 12 4 1700 55 12 local 632 403 402 SR 163 roadway 335 1 12 4 900 20 12 633 404 109 SR 163 collector 3809 1 12 4 1700 55 12 634 405 404 SR 163 collector 1276 1 12 4 1700 55 12 635 406 405 SR 163 collector 2415 1 12 4 1700 55 12 636 407 406 SR 163 collector 3939 1 12 4 1700 55 12 637 408 407 SR 163 collector 3478 1 12 4 1700 55 12 638 409 408 SR 163 collector 3251 1 12 4 1700 55 12 639 410 409 SR 163 collector 1944 1 12 4 1700 55 12 640 411 410 SR 163 collector 5442 1 12 4 1700 55 11 641 412 411 SR 163 collector 4290 1 12 4 1700 55 11 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-65 KLD Engineering, P.C.Rev. 2 642 413 412 1 SR 163 collector 1826 1 12 4 1700 55 11 642 4131 4123 SR 163 collector 2826 1 12 4 1700 55 11 local 644 415 259 N Church St roadway 439 1 12 4 1125 25 11 645 415 263 W Ottawa St collector 681 1 12 4 1750 25 11 646 416 263 SR 19 collector 3564 1 12 4 1750 30 11 647 417 263 E Ottawa St collector 1309 1 12 4 1750 25 11 local 648 418 415 N Church St roadway 420 1 12 4 1125 25 11 local 649 419 416 SR 19 roadway 211 1 12 4 675 15 11 650 420 419 SR 19 collector 1489 1 12 4 1700 40 11 651 421 420 SR 19 collector 2290 1 12 4 1700 55 11 652 422 421 SR 19 collector 7940 1 12 4 1700 60 11 653 423 422 SR 19 collector 5290 1 12 4 1700 60 6 654 423 424 SR 19 collector 8288 1 12 4 1700 60 6 655 424 425 SR 19 collector 425 1 12 4 1700 50 6 656 425 136 SR 19 collector 4726 1 12 4 1700 60 6 657 426 423 County Rd 93 collector 5281 1 12 4 1700 40 6 658 427 214 County Rd 51 collector 5379 1 12 4 1700 60 8 659 427 454 County Rd 51 collector 1426 1 12 4 1700 60 3 660 428 427 Moline Martin Rd collector 4331 1 12 4 1700 55 3 661 429 167 County Rd 51 collector 5170 1 12 4 1700 60 3 662 430 429 County Rd 51 collector 5327 1 12 4 1700 60 3 663 431 432 Main St collector 4291 1 12 4 1700 60 8 Exit Link 432 8432 Lime Rd collector 2979 1 12 4 1700 60 8 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-66 KID Engineering, P.C.Rev. 2 iXIt 433 8433 N 5th St collector 217 1 12 4 1700 45 30 664 434 433 N 5th St collector 230 1 12 4 1700 45 30 N 5th St on-ramp from local 665 434 436 US-20 roadway 583 1 12 4 1125 25 30 666 435 34 US-20 freeway 1124 2 12 4 2250 65 30 667 435 498 US-20 freeway 806 2 12 4 2250 65 30 US-20 off-ramp to N 5th local 668 436 435 St roadway 552 1 12 4 1200 25 30 669 437 434 US-6 collector 1342 1 12 4 1750 45 30 670 437 438 US-6 off-ramp collector 847 1 12 4 1700 40 30 freeway 671 438 34 US-6 on-ramp ramp 835 1 12 4 1700 40 30 672 439 437 US-6 collector 5248 1 12 4 1750 60 31 673 440 439 US-6 collector 4553 1 12 4 1700 60 31 674 441 440 US-6 collector 8198 1 12 4 1700 60 31 675 442 441 US-6 collector 2077 1 12 4 1700 60 31 676 443 442 US-6 collector 4663 1 12 4 1700 60 31 677 444 443 US-6 collector 2375 1 12 4 1700 60 31 678 445 444 US-6 collector 6151 1 12 4 1700 60 31 679 446 2 US-6 collector 5345 1 12 4 1700 60 32 Exit Link 447 8447 US-6 collector 4696 1 12 4 1700 60 32 680 448 445 US-6 collector 1929 1 12 4 1700 60 32 681 448 446 US-6 collector 5333 1 12 4 1700 60 32 682 449 448 SR 510 collector 1522 1 12 4 1700 60 32 683 450 451 SR 105 collector 1188 1 12 4 1700 50 9 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-67 KLD Engineering, P.C.Rev. 2 684 451 199 1 SR 105 collector 7714 1 12 4 1700 50 9 685 452 149 S Howard Rd collector 6892 1 12 4 1700 60 2 686 453 154 Co Rd 228 collector 5261 1 12 4 1700 60 2 687 454 455 W 1st St collector 913 1 12 4 1700 60 3 688 455 430 Ottawa 51 collector 3045 1 12 4 1700 60 3 689 456 239 Benton Carroll Rd collector 8024 1 12 4 1700 60 5 local 690 457 309 Fulton St roadway 4486 1 10 4 1350 30 14 691 457 465 E Lockwood Rd collector 4258 1 10 4 1700 45 14 692 458 333 E State Rd collector 553 1 10 4 1700 45 14 693 458 461 E State Rd collector 6089 1 10 4 1700 45 14 694 459 460 E State Rd collector 2350 1 10 4 1700 45 17 695 460 466 E State Rd collector 1485 1 10 4 1700 45 17 696 461 458 E State Rd collector 6089 1 10 4 1700 45 14 697 461 459 E State Rd collector 1400 1 10 4 1700 45 17 698 462 463 S Plasterbed Rd collector 1247 1 10 4 1700 45 17 699 463 464 S Plasterbed Rd collector 1568 1 10 4 1700 45 17 700 464 461 S Plasterbed Rd collector 2649 1 10 4 1700 45 17 701 465 462 E Lockwood Rd collector 8729 1 10 4 1700 45 14 702 466 91 E State Rd collector 3200 1 10 4 1750 45 17 703 467 466 S Lake Rd collector 4948 1 10 4 1700 45 17 704 468 469 Corduroy Rd collector 5348 1 12 4 1700 60 1 705 469 470 Corduroy Rd collector 10448 1 12 4 1700 60 1 706 470 471 Corduroy Rd collector 10764 1 12 4 1700 60 1 707 471 490 S Wynn Rd collector 2693 1 12 4 1700 45 <Null>708 472 156 SR 2 minor 5172 2 12 4 1700 60 1 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-68 KLD Engineering, P.C.Rev. 2 Up- Don No Saturaton Fre Strea StemRarter ay f Ln hude lw Foa Exit Link minor arterial 41 1700<Null>472 8156 SR 2 5200 2 12 OU 709 473 265 SR 19 collector 3899 1 12 4 1700 55 11 710 474 483 County Rd 182 collector 2856 1 10 2 1700 45 23 711 477 478 County Rd 36 collector 2918 1 10 2 1700 45 11 712 478 473 County Rd 36 collector 2861 1 10 2 1700 45 11 713 479 474 County Rd 182 collector 10558 1 10 2 1700 45 11 W Portage South River 714 479 480 Rd collector 10556 1 10 2 1700 45 11 715 480 477 Grandview Dr collector 668 1 10 2 1700 45 11 716 481 479 County Rd 182 collector 1290 1 10 2 1700 45 11 W Portage South River 717 482 481 Rd collector 7606 1 10 2 1700 45 11 718 483 491 County Rd 182 collector 12570 1 12 4 1700 45 23 719 484 488 Country Rd 6 collector 2669 1 12 4 1750 40 21 720 485 484 Country Rd 6 collector 5253 1 12 4 1700 50 21 721 486 485 Country Rd 6 collector 5297 1 12 4 1700 50 21 722 487 185 SR 590 collector 10526 1 12 4 1700 60 22 723 487 486 Country Rd 6 collector 5369 1 12 4 1700 50 22 724 488 200 Country Rd 6 collector 298 1 12 4 1700 40 21 725 489 488 Country Rd 7 collector 1109 1 12 4 1750 40 21 726 490 472 S Wynn Rd collector 5261 1 10 2 1700 45 <Null>727 491 27 County Rd 182 collector 285 1 10 2 1575 35 28 local 728 496 131 Harris Harbor Dr roadway 1253 1 12 4 1350 35 6 729 497 46 US-20 off-ramp to US-6 freeway 191 1 12 4 1700 60 26 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-69 KLD Engineering, P.C.Rev. 2 Up Down No Sauain Fe ramp 730 498 435 US-20 freeway 806 2 242250 6530 Exit Link 498 8435 US-20 freeway 733 2 12 4 2250 65 30 731 499 7 SR 53 collector 245 1 12 4 1700 30 30 Exit Link 499 8009 SR 53 collector 253 1 12 4 1700 30 30 732 500 7 US 6 off-ramp to SR 53 collector 896 1 12 4 1900 30 30 freeway 733 500 32 US 6 on-ramp from SR 53 ramp 1105 1 12 4 1700 45 30 734 8051 51 US-20 freeway 1018 2 12 4 1900 60 29 735 8053 53 US-6 freeway 1106 1 12 4 1700 60 26 736 8059 59 US-20 freeway 1461 2 12 4 1900 60 21 737 8069 69 1-80 freeway 4032 3 12 4 2250 70 20 738 8079 79 1-90 freeway 2599 3 12 4 2250 70 31 739 8435 498 US-20 freeway 734 2 12 4 2250 65 30 Davis-Besse Nuclear Power Station K-70 KLD Engineering, P.C.Evacuation Time Estimate Rev. 2 Table K-2. Nodes In the Link-Node Analysis Network which are Controlled.s .y. .-S S.Cordnae Coriat' Cnto a 1 1730537 719496 TCP I 3 1799148 624582 Pre-timed 30 4 1799114 622310 Pre-timed 30 6 1799111 621558 Pre-timed 30 7 1799108 619362 Pre-timed 30 25 1840087 668414 TCP 13 26 1802015 631326 Pre-timed 28 27 1807634 639973 Stop 28 29 1797644 620472 Yield 29 33 1795211 620581 Yield 29 34 1806692 619260 Yield 30 37 1793327 620645 Yield 29 39 1794307 620992 Pre-timed 29 40 1794300 619942 Pre-timed 29 46 1786804 619410 Stop 29 50 1787925 619792 Yield 29 54 1770447 629672 Pre-timed 26 58 1749250 641481 Stop 21 65 1754255 653226 Yield 21 91 1870067 671151 TCP 17 109 1831061 675048 TCP 12 111 1826103 679529 TCP 12 118 1809784 692709 Stop 6 120 1822050 682253 Stop 12 126 1807896 695684 TCP 6 128 1805276 704356 Stop 6 131 1803885 706253 Stop 6 132 1802587 706302 Stop 6 134 1799116 706425 Stop 6 136 1791985 706448 Stop 6 137 1779118 706521 Stop 5 141 1781806 706425 TCP 5 142 1776503 706521 Stop 5 143 1771067 706677 Stop 5 145 1761779 706780 TCP 4 149 1757149 719418 TCP 2 151 1757072 727667 TCP 2 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-71 KLD Engineering, P.C.Rev. 2 x6 .*.Cordnae Coriat' Cnto a 153 1751824 727510 TCP 2 154 1751824 719546 TCP 2 158 1730476 714232 Stop 1 159 1730476 712655 Stop 3 160 1731246 712174 Stop 3 163 1731292 706676 Stop 3 167 1733664 706696 Stop 3 173 1760455 706750 Stop 4 181 1770720 674724 TCP 10 182 1770757 666389 TCP 10 198 1750710 660110 Pre-timed 21 199 1750248 661196 Stop 21 204 1739430 674767 Pre-timed 9 209 1733404 680367 Pre-timed 8 216 1733328 675763 Pre-timed 8 218 1733311 674731 Pre-timed 8 223 1781302 674663 TCP 10 227 1789500 672569 Stop 11 228 1789512 671627 TCP 11 234 1781317 668875 Stop 10 241 1781755 701137 Stop 5 243 1760189 683943 Stop 9 246 1760162 666874 Stop 9 258 1791149 671388 Pre-timed 11 260 1791834 671383 TCP 11 263 1791837 672223 Pre-timed 11 284 1794343 622090 Pre-timed 29 298 1844403 670827 TCP 13 300 1844635 670958 Stop 13 302 1845702 670555 Stop 13 303 1847722 670556 Stop 14 305 1847718 671550 Pre-timed 14 306 1848228 670561 Pre-timed 14 308 1848219 671554 Pre-timed 14 311 1848231 672617 Pre-timed 14 312 1848231 673111 TCP 14 313 1847705 672617 Stop 14 314 1847693 672106 Pre-timed 14 Davis-Besse Nuclear Power Station Evacuation Time Estimate K-72 KLD Engineering, P.C.Rev. 2 316 a1847687 C673111 t Actuated a14 317 1846210 672105 Stop 13 319 1847197 673110 TCP 14 326 1849678 673240 Stop 14 329 1853146 673544 Pre-timed 14 331 1855406 673589 TCP 14 340 1858109 674062 Yield 14 341 1858290 674082 Pre-timed 14 349 1869177 676488 Pre-timed 17 351 1870286 676831 TCP 17 358 1878176 679623 Pre-timed 16 361 1878335 672917 Stop 18 371 1872359 671160 Stop 18 381 1876425 699225 Stop 7 385 1875445 699215 Stop 7 401 1833599 675982 Stop 12 405 1825995 674658 Stop 12 423 1792048 693008 Stop 6 427 1733507 690815 Stop 3 434 1807109 618140 Pre-timed 30 435 1807611 618629 Yield 30 437 1808207 618913 Pre-timed 30 448 1838732 634940 Stop 32 461 1861785 671303 Stop 17 462 1862653 665996 Stop 17 466 1866868 671292 Stop 17 473 1791702 667641 Stop 23 477 1797043 665682 Stop 11 488 1752274 658877 Pre-timed 21 490 1714643 724791 Stop 28'Coordinates are given in the North American Datum of 1983, State Plane Ohio North Davis-Besse Nuclear Power Station Evacuation Time Estimate K-73 KILD Engineering, P.C.Rev. 2