MONTHYEARLR-N05-0401, Response to Generic Letter 2004-02 Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors2005-09-0101 September 2005 Response to Generic Letter 2004-02 Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0603801012006-02-0909 February 2006 Request for Additional Information Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized Water Reactors Project stage: RAI ML0620705242006-08-11011 August 2006 Approval of Generic Letter 2004-02 Extension Request Project stage: Other ML0729502752007-10-24024 October 2007 Draft Open Items from Staff Audit of Corrective Actions to Address Generic Letter 2004-02 Project stage: Draft Other ML0735312612007-12-10010 December 2007 Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request LR-N07-0304, Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors2007-12-10010 December 2007 Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0808004692008-02-29029 February 2008 Supplemental Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0819101522008-06-26026 June 2008 Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request LR-N08-0139, Request for Extension to Complete Generic Letter 2004-02 Testing2008-06-26026 June 2008 Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request ML0818305512008-06-30030 June 2008 Draft Request for Additional Information, Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Draft RAI LR-N08-0160, Response to NRC Request for Information Regarding Request for Extension to Complete Generic Letter 2004-02 Testing2008-07-10010 July 2008 Response to NRC Request for Information Regarding Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request ML0820400132008-07-31031 July 2008 Approval of Request for Extension of Completion Date for Generic Letter 2004-02 Corrective Actions Project stage: Other ML0821705062008-08-12012 August 2008 Report on Results of Staff Audit of Corrective Actions to Address Generic Letter 2004-02 Project stage: Other ML0833000792008-12-17017 December 2008 Request for Additional Information Regarding Generic Letter 2004-02 Project stage: RAI ML0910005572009-03-31031 March 2009 Updated Supplemental Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0933802422009-12-0404 December 2009 Draft Request for Additional Information Project stage: Draft RAI ML1002205202010-02-0404 February 2010 Request for Additional Information Regarding Generic Letter 2004-02 Project stage: RAI ML1003411882010-02-17017 February 2010 Notice of Forthcoming Meeting with PSEG Nuclear LLC (PSEG) Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Unit Nos. 1 and 2 Project stage: Request ML1007704112010-04-0707 April 2010 Summary of Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Unit Nos. 1 and 2 Project stage: Meeting ML1015401372010-05-27027 May 2010 Draft Salem, Units 1 and 2, Updated Supplemental Response to Generic Letter 2004-02 ML1015405252010-06-0808 June 2010 Notice of Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 Project stage: Meeting ML1018004772010-07-14014 July 2010 Summary of Category 1 Public Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 Project stage: Meeting ML12129A3892012-04-27027 April 2012 Attachment 1 to LR-N12-0124, Generic Letter 2004-02, Updated Supplemental Response for Salem Regarding Generic Letter 2004-02 Project stage: Request ML12129A3902012-04-27027 April 2012 Attachments 1 Through Attachment 8, Response to Generic Letter 2004-02 Project stage: Request ML12129A3882012-04-27027 April 2012 Final Supplemental Response to Generic Letter 2004-02 Project stage: Request ML12366A2952012-11-0808 November 2012 Bypass Test Fiber Debris Preparation Method Comparison 11/8/2012_NRC Project stage: Request ML12366A2972012-11-0808 November 2012 Bypass Testing Information Project stage: Request ML12338A3802012-12-0303 December 2012 E-mail - Questions Regarding Salem Bypass Testing for PSEG (GL 2004-02) Project stage: Other ML12338A3832012-12-0303 December 2012 Questions on Salem Bypass Testing R1 Clean Project stage: Other ML13010A3252013-01-30030 January 2013 Summary of Public Conference Call with PSEG: Final Supplemental Response to Generic Letter 2004-02 Project stage: Other ML14113A2022014-04-30030 April 2014 Closeout of Generic Letter, 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors (Tac Nos. MC4712 and MC4713) Project stage: Other 2009-12-04
[Table View] |
Similar Documents at Salem |
|---|
|
Text
SALEM BYPASS TESTING INFORMATION At Salem bypass tests were done at CCI facility in 2006 and 2008.
The 2006 tests were performed in the Multi Functional Test Loop (MFTL). This test loop had 40 pocket 1-sided strainer modules installed at one end of the flume. The top 20 pockets were blocked off in order to more closely simulate the height of the installed strainers at Salem. The tests were run primarily with NUKON only (1 test included Kaowool). The fiber was not baked in these tests.
The 2008 tests were also performed in the MFTL. The test loop had a 42 pocket strainer test module (2 sides which are each 3 pockets wide by 7 pockets tall) which was placed near the middle of the flume. The strainer module was prototypical (i.e. based on the installed strainer design) and was manufactured specifically for the Salem testing. The tests included three fiber types in the fiber debris mixture (NUKON, Kaowool, and Fiberglas). The NUKON and Kaowool fiber was baked in these tests to simulate exposure to hot surfaces. The Fiberglas fiber was not baked because it is not installed on hot piping in the plant.
The NRC Staff witnessed Salem strainer head loss tests performed in the MFTL with the 2-sided test module on April 20-25, 2008. The NRC observations from these tests are documented in a trip report dated July 16, 2008 (ADAMS Accession No. ML081640193). In this report, the NRC concluded that the test methods, including fiber debris preparation methodology, employed by CCI were generally prototypical or conservative. The fiber debris bypass tests conducted in 2008 utilized the same fiber preparation methodology as was witnessed during the strainer head loss tests. In addition, in the fall of 2007, debris samples similar to the debris used in MFTL testing prepared by CCI were provided to the NRC staff for review.
The preparation of the fibrous debris used in the bypass tests as described in Section 3f.4.1.5.7.1 of the final supplemental response submitted in April 2012 (PSEG letter LR-N12-0124) is also consistent with the fibrous debris preparation guidelines issued by NEI in January 2012.
A detailed discussion of the 2006 and 2008 Salem fiber bypass tests has been provided to the NRC in Section 3f.4.1.3 and 3f.4.1.6 of the Salem final supplemental response. The methodology to determine the amount of bypass through the strainer modules was same in both 2006 and 2008 tests and is summarized below.
- A 0.31 mm stainless steel mesh was placed in the test loop to collect the bypassed fiber.
- Samples were taken periodically from the test loop to determine the bypassed fiber size distribution.
- The dry weight of the collection screen was recorded prior to and after each test. The difference in the two weights is the mass of material which bypassed the strainers.
- The fiber concentration in each grab sample was determined by passing the sampled water through two consecutive paper filters with a screen size of 8 microns and 0.45 microns, respectively.
- The mass of material on the collection screen was combined with the mass of material from the grab samples to determine the total mass of fiber bypass.