MONTHYEARLR-N05-0401, Response to Generic Letter 2004-02 Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors2005-09-0101 September 2005 Response to Generic Letter 2004-02 Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0603801012006-02-0909 February 2006 Request for Additional Information Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized Water Reactors Project stage: RAI ML0620705242006-08-11011 August 2006 Approval of Generic Letter 2004-02 Extension Request Project stage: Other ML0729502752007-10-24024 October 2007 Draft Open Items from Staff Audit of Corrective Actions to Address Generic Letter 2004-02 Project stage: Draft Other ML0735312612007-12-10010 December 2007 Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request LR-N07-0304, Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors2007-12-10010 December 2007 Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0808004692008-02-29029 February 2008 Supplemental Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0819101522008-06-26026 June 2008 Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request LR-N08-0139, Request for Extension to Complete Generic Letter 2004-02 Testing2008-06-26026 June 2008 Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request ML0818305512008-06-30030 June 2008 Draft Request for Additional Information, Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Draft RAI LR-N08-0160, Response to NRC Request for Information Regarding Request for Extension to Complete Generic Letter 2004-02 Testing2008-07-10010 July 2008 Response to NRC Request for Information Regarding Request for Extension to Complete Generic Letter 2004-02 Testing Project stage: Request ML0820400132008-07-31031 July 2008 Approval of Request for Extension of Completion Date for Generic Letter 2004-02 Corrective Actions Project stage: Other ML0821705062008-08-12012 August 2008 Report on Results of Staff Audit of Corrective Actions to Address Generic Letter 2004-02 Project stage: Other ML0833000792008-12-17017 December 2008 Request for Additional Information Regarding Generic Letter 2004-02 Project stage: RAI ML0910005572009-03-31031 March 2009 Updated Supplemental Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0933802422009-12-0404 December 2009 Draft Request for Additional Information Project stage: Draft RAI ML1002205202010-02-0404 February 2010 Request for Additional Information Regarding Generic Letter 2004-02 Project stage: RAI ML1003411882010-02-17017 February 2010 Notice of Forthcoming Meeting with PSEG Nuclear LLC (PSEG) Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Unit Nos. 1 and 2 Project stage: Request ML1007704112010-04-0707 April 2010 Summary of Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Unit Nos. 1 and 2 Project stage: Meeting ML1015401372010-05-27027 May 2010 Draft Salem, Units 1 and 2, Updated Supplemental Response to Generic Letter 2004-02 ML1015405252010-06-0808 June 2010 Notice of Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 Project stage: Meeting ML1018004772010-07-14014 July 2010 Summary of Category 1 Public Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2 Project stage: Meeting ML12129A3892012-04-27027 April 2012 Attachment 1 to LR-N12-0124, Generic Letter 2004-02, Updated Supplemental Response for Salem Regarding Generic Letter 2004-02 Project stage: Request ML12129A3902012-04-27027 April 2012 Attachments 1 Through Attachment 8, Response to Generic Letter 2004-02 Project stage: Request ML12129A3882012-04-27027 April 2012 Final Supplemental Response to Generic Letter 2004-02 Project stage: Request ML12366A2952012-11-0808 November 2012 Bypass Test Fiber Debris Preparation Method Comparison 11/8/2012_NRC Project stage: Request ML12366A2972012-11-0808 November 2012 Bypass Testing Information Project stage: Request ML12338A3802012-12-0303 December 2012 E-mail - Questions Regarding Salem Bypass Testing for PSEG (GL 2004-02) Project stage: Other ML12338A3832012-12-0303 December 2012 Questions on Salem Bypass Testing R1 Clean Project stage: Other ML13010A3252013-01-30030 January 2013 Summary of Public Conference Call with PSEG: Final Supplemental Response to Generic Letter 2004-02 Project stage: Other ML14113A2022014-04-30030 April 2014 Closeout of Generic Letter, 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors (Tac Nos. MC4712 and MC4713) Project stage: Other 2009-12-04
[Table View] |
Similar Documents at Salem |
|---|
|
Text
PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 0 PSEG Nuclear LLC 10 CFR 50.54(f)
LR-N12-0124 April 27, 2012 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Salem Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-70 and DPR-75 NRC Docket Nos. 50-272 and 50-311
Subject:
References:
Final Supplemental Response to Generic Letter 2004-02 (1)
NRC Generic Letter 2004-02: Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors, September 13, 2004, ADAMS Accession No. ML042360586 (2)
Draft Salem, Units 1 and 2, Updated Supplemental Response to Generic Letter 2004-02, May 27, 2010, ADAMS Accession No. ML101540137 (3) 6/23/2010 Summary of Category 1 Public Meeting with PSEG Nuclear LLC, Regarding Response to Generic Letter 2004-02 for Salem Nuclear Generating Station, Units 1 and 2, ADAMS Accession No. ML101800477 On September 13, 2004, the NRC issued the Reference 1 letter, Generic Letter (GL) 2004-02.
GL 2004-02 requested that each plant perform an evaluation of the Emergency Core Cooling System and Containment Spray System recirculation functions in light of the information provided in the Generic Letter, and, if appropriate, take additional actions to ensure system function.
PSEG Nuclear LLC (PSEG) provided a number of responses to GL 2004-02, including a draft updated supplemental response on May 27, 2010 (Reference 2). The NRC staff provided feedback to PSEG on the revised draft response during a public meeting on June 23, 2010, summarized in Reference 3. PSEG hereby submits the final supplemental response to Generic Letter 2004-02 as Attachments 1 through 8.
There are no new regulatory commitments contained in this submittal.
If you have any questions or require additional information, please do not hesitate to contact Ms.
Emily Maguire at (856) 339-1023.
95-2168 REV. 7/99
LR-N12-0124 Page 2 10 CFR 50.54(f)
I declare under penalty of perjury that the foregoing is true and correct.
Executed on (Date)
Carl/J. Fricker Site Vice President - Salem Generating Station Attachments
- 1. Final Supplemental Response for Salem
- 2. Updated Response to February 9, 2006 RAIs
- 3. Updated Response to Draft Audit Open Items
- 4. Updated Response to Final Audit Open Items
- 5. Updated Response to December 17, 2008 RAIs
- 6. References
- 7. CSS and ECCS P&ID Drawings
- 8. Response to February 4, 2010 RAIs cc:
Mr. W. Dean, Administrator, Region I, NRC Mr. J. Hughey, Project Manager, NRC NRC Senior Resident Inspector, Salem Mr. P. Mulligan, Manager IV, NJBNE Mr. L. Marabella, Corporate Commitment Tracking Coordinator Mr. T. Cachaza, Salem Commitment Tracking Coordinator