Schaperow, Jason From:

Schaperow, Jason Sent:

Friday, January 07, 2011 8:17 AM To:

'Ross, Kyle Wayne'

Subject:

RE: RES management Thanks for the feedback.

From: Ross, Kyle Wayne [mailto:kwross~sandia.govl Sent: Thursday, January 06, 2011 6:43 PM To: Schaperow, Jason

Subject:

RE: RES management Thanks.

I got with KC and Mark about Peach Bottom reactor building overpressure failure. A 1,000 m2 flow path is opened to the environment given a 0.5 psi pressure rise in the building. This represents failure of the refueling bay roof.

Your pictures of LHSI piping in the Safeguards Area show bare piping (no insulation).

Kyle From: Schaperow, Jason rmailto:Jason.Schaperow~cnrc.olovI Sent: Thursday, January 06, 2011 2:15 PMV To: Ross, Kyle Wayne

Subject:

RES management For your information...

My new chain of command is as follows:

Brian Sheron, Director of RES Jennifer, Deputy Director of RES Kathy Gibson, Acting Director of DSA (Division of Safety Analysis)

Mike Scott, Acting Deputy Director of DSA Patricia (Pat) Santiago, Chief Special Projects Branch Also, we have a new PM for SOARCA, Richard Chang.

1' 3c