ML12130A207
| ML12130A207 | |
| Person / Time | |
|---|---|
| Site: | Surry (DPR-032, DPR-037) |
| Issue date: | 04/25/2012 |
| From: | Stanley B Virginia Electric & Power Co (VEPCO) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 12-270 | |
| Download: ML12130A207 (31) | |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 April 25, 2012 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Serial No.12-270 SS&L/JSA RO Docket Nos.
50-280 50-281 License Nos. DPR-32 DPR-37 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS I AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed is the Surry Power Station Annual Radioactive Effluent Release Report for January 1, 2011 through December 31, 2011. The report, submitted pursuant to Surry Power Station Technical Specification 6.6.B.3, includes a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released during the 2011 calendar year, as outlined in Regulatory Guide 1.21, Revision 1, June 1974.
If you have any further questions, please contact Jason Eggart at 757-365-2010.
Sincerely, B. L. Stanley Director Safety & Licensing Surry Power Station Attachment Commitments made in this letter: None cc:
U. S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303-1257 NRC Senior Resident Inspector Surry Power Station
~8
Serial No.12-270 SPS Annual Rad Effluent Report Docket Nos.: 50-280, 50-281 ATTACHMENT 1
,2011 Annual Radioactive Effluent Release Report SURRY POWER STATION UNITS 1 AND 2 VIRGINIA ELECTRIC AND POWER COMPANY
Surry Power Station 2011 Annual Radioac*K Effluent Release kepr'Tw D
Domi ni o.
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SURRY POWER STATION January 1, 2011 through December 31, 2011 Prepared By:
Reviewed By:
Reviewed By:
Approved By:
P. F. Blount Health Physicist P. R. Harris Supervisor Radiological Analysis Supervisor Health Physics Technical Services Manager Radiological Protection and Chemistry
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR THE SURRY POWER STATION January 1, 2011 through December 31, 2011 Index Section No.
1 2
Subject Executive Summary Purpose and Scope Page 1
2 3
4 Discussion Supplemental Attaclunent 1 3
Information 4
Effluent Release Data Annual and Quarterly Doses Revisions to Offsite Dose Calculation Manual (ODCM)
Major Changes to Radioactive Liquid, Gaseous and Solid Waste Treatment Systems Inoperability of Radioactive Liquid and Gaseous Effluent Monitoring Instrumentation Unplanned Releases Lower Limit of Detection (LLD) for Effluent Sample Analysis Industry Ground Water Protection Initiative
FORWARD This report is submitted as required by Appendix A to Operating License Nos. DPR-32 and DPR-37, Technical Specifications for Surry Power Station, Units I and 2, Virginia Electric and Power Company, Docket Nos. 50-280, 50-281, Section 6.6.B.3.
EXECUTIVE
SUMMARY
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT The Annual Radioactive Effluent Release Report describes the radiological effluent control program conducted at Surry Power Station during the 2011 calendar year.
This document summarizes the quantities of radioactive liquid and gaseous effluents and solid waste released from Surry Power Station in accordance with Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants", Revision 1, June 1974. The report also includes an assessment of radiation doses to the maximum exposed member of the public due to the radioactive liquid and gaseous effluents.
During this reporting period, there were no unplanned liquid or gaseous effluent releases as classified according to the criteria in the Offsite Dose Calculation Manual.
Based on the 2011 effluent release data, 10CFR50 Appendix I dose calculations were performed in accordance with the Offsite Dose Calculation Manual. The dose calculations are as follows:
- 1. The total body dose due to liquid effluents was 1.59-04 mrem, which is 2.65-03% of the 6 mrem dose limit. The critical organ doses due to liquid effluents, GI-LLI and Liver respectively, were 2.70E-04 mrem and 1.56E-04 mrem. These doses are 1.35E-03% and 7.80E-04% of the respective 20 mrem dose limit.
- 2. The air dose due to noble gases in gaseous effluents was 2.12E-04 mrad gamma, which is 1.06E-03% of the 20 mrad gamma dose limit, and 3.05E-04 n-rad beta, which is 8.75E-04% of the 40 mrad beta dose limit.
- 3.
The critical organ dose from gaseous effluents due to 1-131, 1-133, H-3, and particulates with half-lives greater than 8 days is 2.64E-01 mrem, which is 8.80E-01% of the 30 mrem dose limit.
There were no major changes to the radioactive liquid, gaseous or solid waste treatment systems during this reporting period.
There were no changes to VPAP-2103S, Offsite Dose Calculation Manual, during this reporting period.
In accordance with the Nuclear Energy Institute (NEI) Industry Ground Water Protection Initiative, analysis results of ground water monitoring locations not included in the Radiological Environmental Monitoring Program (REMP), will be included in this report.
Ground water monitoring well sample results are provided in Attachment 8.
I
Based on the radioactivity measured and the dose calculations performed during this reporting period, the operation of Surry Power Station has resulted in negligible radiation dose consequences to the maximum exposed member of the public in unrestricted areas.
Purpose and Scope Attachment I includes a summary of the quantities of radioactive liquid and gaseous effluents and solid waste as outlined in Regulatory Guide 1.21, with data summarized on a quarterly or annual basis following the format of Tables 1, 2 and 3 of Appendix B, thereof. Attachment 2 of this report includes an assessment of radiation doses to the maximum exposed member of the public due to radioactive liquid and gaseous effluents released from the site during 2011.
As required by Technical Specification 6.8.B, changes to the Offsite Dose Calculation Manual (ODCM) for the time period covered by this report are included in Attachment 3. Major changes to the radioactive liquid, gaseous and solid waste treatment systems are reported in Attachment 4, as required by the ODCM, Section 6.7.2. If changes are made to these systems, the report shall include information to support the reason for the change and a summary of the IOCFR50.59 evaluation. In lieu of reporting major changes in this report, major changes to the radioactive waste treatment systems may be submitted as part of the annual FSAR update.
As required by the ODCM, Sections 6.2.2 and 6.3.2, a list and explanation for the inoperability of radioactive liquid and/or gaseous effluent monitoring instrumentation is provided in Attachment 5 of this report. Additionally, a list of unplanned releases during the reporting period is included in. provides the typical lower limit of detection (LLD) capabilities of the radioactive effluent analysis instrumentation.
As required by the ODCM, Section 6.7.5, a summary of on-site radioactive spills or leaks that were communicated in accordance with the Industry Ground Water Protection Initiative reporting protocol, and sample analyses from ground water wells that are not part of the Radiological Environmental Monitoring Program are provided in Attachment 8.
2
Discussion The basis for the calculation of the percent of technical specification for the critical organ in Table IA of Attachment I is the ODCM, Section 6.3.1, which requires that the dose rate for iodine-131, iodine-133, for tritium, and for all radionuclides in particulate form with half-lives greater than 8 days shall be less than or equal to 1500 mrem/yr to the critical organ at or beyond the site boundary.
The critical receptor is the child via the inhalation pathway.
The basis for the calculation of the percent of technical specification for the total body and skin in Table 1 A of Attachment I is the ODCM, Section 6.3.1, which requires that the dose rate for noble gases to areas at or beyond site boundary shall be less than or equal to 500 mrem/yr to the total body and less than or equal to 3000 mrem/yr to the skin.
The basis for the calculation of the percent of technical specification in Table 2A of Attachment 1 is the ODCM, Section 6.2.1, which states that the concentration of radioactive material releases in liquid effluents to unrestricted areas shall not exceed ten times the concentrations specified in IOCFR20, Appendix B, Table 2, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.OOE-04 microcuries/mL.
Percent of technical specification calculations are based on the total gaseous or liquid effluents released for the respective quarter.
The annual and quarterly doses, as reported in Attachment 2, were calculated according to the methodology presented in the ODCM. The beta and gamma air doses due to noble gases released from the site were calculated at the site boundary. The maximum exposed member of the public from the release of airborne iodine-131, iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days, was a child at 2.05 miles with the critical organ being the bone via the ingestion pathway. The maximum exposed member of the public from radioactive materials in liquid effluents in unrestricted areas was an adult, exposed by either the invertebrate or fish pathway, with the critical organ typically being the gastrointestinal-lower large intestine. The total body dose was also determined for this individual.
During 2011, effluent samples identified detectable concentrations of iodine-131 that could be related to the operation of Surry Power Station in March and April. The concentrations detected were above levels historically observed for the station's operational status during that period.
Concentrations returned to those historically observed levels after April. Given the events of March 2011 at the Daiichi nuclear power plant, Fukushima Japan and the associated airborne releases and subsequent trans-Pacific transportation, the slightly elevated concentrations detected in March and April are reasonably attributed to the Daiichi releases. However, the concentrations detected at Surry Power Station and projected doses are conservatively included in this report for completeness.
3
Presented in Attachment 6 is a list of unplanned gaseous and liquid releases as required by the ODCM, Section 6.7.2.
The typical lower limit of detection (LLD) capabilities of the radioactive effluent analysis instrumentation are presented in Attachment 7. These LLD values are based upon conservative conditions (i.e., minimum sample volumes and maximum delay time prior to analysis). Actual LLD values may be lower. If a radioisotope was not detected when effluent samples were analyzed, then the activity of the radioisotope was reported as Not Detected (N/D) on Attachment I of this report. When all isotopes listed on Attachment 1 for a particular quarter and release mode are less than the lower limit of detection, then the totals for this period will be designated as Not Applicable (N/A).
Supplemental Information Section 6.6.1 of the ODCM requires the identification of the cause(s) for the unavailability of milk, or if required, leafy vegetation samples, and the identification for obtaining replacement samples.
As milk was available for collection during this reporting period, leafy vegetation sampling was not required.
As required by the ODCM, Section 6.6.2, evaluation of the Land Use Census is made to determine if new sample location(s) must be added to the Radiological Environmental Monitoring Program.
Evaluation of the Land Use Census conducted for this reporting period identified no change in sample locations for the Radiological Environmental Monitoring Program.
4
Attachment I EFFLUENT RELEASE DATA January 1, 2011 through December 31, 2011 This attachment includes a summary of the quantities of radioactive liquid and gaseous effluents and solid waste as outlined in Regulatory Guide 1.21, Appendix B.
TABLE IA Page 1 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 GASEOUS EFFLUENT-SUMMATION OF ALL RELEASES I
SURRY POWER STATION UNITS 1&2 UNIT FIRST SECOND
% EST. ERROR QUARTER QUARTER A. FISSION & ACTIVATION GASES I.
TOTAL RELEASE Ci 2.88E-01 3.66E-0I 1.80E+01
- 2. AVE RELEASE RATE FOR PERIOD jtCi/sec 3.70E-02 4.66E-02 B. IODINE I. TOTAL 1-131 Ci 1.30E-05 6.20E-06 2.80E+O1
- 2. AVE RELEASE RATE FOR PERIOD
[tCi/sec 1.68E-06 7.89E-07 I
C. PARTICULATE I1. HALF-LIFE >8 DAYS Ci 4.59E-06 1.09E-05 2.80E+01
- 2. AVE RELEASE RATE FOR PERIOD gCi/sec 5.90E-07 1.39E-06
- 3. GROSS ALPHA RADIOACTIVITY Ci N/D N/D D. TRITIUM
- 1. TOTAL RELEASE Ci 7.40E+00 1.27E+01 3.10E+01
- 2. AVE RELEASE RATE FOR PERIOD
[tCi/sec 9.52E-01 1.62E+00 E. CARBON-14 I. TOTALRELEASE Ci 6.54E+00 8.33E+00
- 2. AVE RELEASE RATE FOR PERIOD tiCi/sec 8.41E-07 1.06E-06 PERCENTAGE OF T.S. LIMITS CRITICAL ORGAN DOSE RATE 4.38E-03 1.33E-02 TOTAL BODY DOSE RATE 7.52E-06 1.40E-04 SKIN DOSE RATE 2.87E-06 3.72E-05
Attachment I TABLE IA Page 2 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 GASEOUS EFFLUENT-SUMMATION OF ALL RELEASES I
SURRY POWER STATION UNITS l&2 UNIT THIRD FOURTH
% EST. ERROR QUARTER QUARTER A. FISSION & ACTIVATION GASES I. TOTAL RELEASE Ci 9.63E-02 2.38E-03 1.80E+01
- 2. AVE RELEASE RATE FOR PERIOD j.Ci/sec 1.21E-02 2.99E-04 "B.
- 1. TOTAL 1-131 Ci N/D N/D 2.80E+01
- 2. AVE RELEASE RATE FOR PERIOD
[iCi/sec N/A N/A C. PARTICULATE I.
HALF-LIFE >8 DAYS Ci N/D N/D 2.80E+O1
- 2. AVE RELEASE RATE FOR PERIOD liCi/sec N/A N/A
- 3. GROSS ALPHA RADIOACTIVITY Ci N/D N/D D. TRITIUM
- 1. TOTAL RELEASE Ci 9.56E+00 8.48E+00 3.10E+01
- 2. AVE RELEASE RATE FOR PERIOD iiCi/sec 1.20E+00 1.07E+00 I. TOTAL RELEASE Ci 2.19E+00 5.41 E-02
- 2. AVE RELEASE RATE FOR, PERIOD ttCi/sec 2.76E-07 6.81 E-09 PERCENTAGE OF T.S. LIMITS CRITICAL ORGAN DOSE RATE 2.28E-02 7.38E-04 TOTAL BODY DOSE RATE 6.78E-06 4.91 E-06 SKIN DOSE RATE 1.97E-05 1.76E-06
Attachment I Page 3 of 12 TABLE IB EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 GASEOUS EFFLUENTS-MIXED MODE RELEASES CONTINUOUS MODE BATCH MODE SURRY POWER STATION UNITS 1&2
- 1. FISSION & ACTIVATION GASES Kr-85 Kr-85rm Kr-87 Kr-88 Xe-133 Xe-135 Xe-135m Xe-138 Xe-131m Xe-133m Ar-41 UNIT FIRST SECOND QUARTER QUARTER FIRST SECOND QUARTER QUARTER Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D NID N/D N/D N/A N/D 2.45E-04 N/D N/D 2.55E-01 2.OOE-02 N/D N/D N/D 2.72E-03 5.19E-04 2.78E-01 N/D N/D N/D N/D 3.35E-01 1.66E-04 N/D N/D N/D 9.93E-04 N/D 3.36E-01 TOTAL FOR PERIOD Ci N/A
- 2. IODINES 1-131 1-133 1-135 Ci Ci Ci N/D N/D N/D TOTAL FOR PERIOD
- 3. PARTICULATES Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Co-58 Co-60 Mn-54 Fe-59 Zn-65 Mo-99 Ce-141 Ce-144 C-14 TOTAL FOR PERIOD Ci N/A Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 6.34E+00 N/A N/D NID N/D N/D N/D NID N/D N/D N/D NID N/D N/D NID N/D 7.64E+00 N/D N/D N/D NID N/D N/D Ci N/A N/A 6.34E+00 7.64E+00
TABLE 1B Page 4 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: I/I/11 TO 12/31/11 GASEOUS EFFLUENTS-MIXED MODE RELEASES CONTINUOUS MODE BATCH MODE SURRY POWER STATION UNITS 1&2
- 1. FISSION & ACTIVATION GASES Kr-85 Kr-85m Kr-87 Kr-88 Xe-133 Xe-135 Xe-135m Xe-138 Xe-131m Xe-133m Ar-41 TOTAL FOR PERIOD UNIT THIRD FOURTH THIRD FOURTH QUARTER QUARTER QUARTER QUARTER Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/A N/D N/D N/D N/D 4.09E-02 N/D N/D N/D N/D N/D N/D 4.09E-02 N/D N/D N/D N/D 5.80E-04 N/D N/D N/D N/D N/D N/D 5.80E-04 Ci N/A
- 2. IODINES 1-131 1-133 1-135 Ci Ci Ci N/D N/D N/D N/D N/D N/D N/D N/D N/D N/A N/D N/D N/D N/A TOTAL FOR PERIOD
- 3. PARTICULATES Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Co-58 Co-60 Mn-54 Fe-59 Zn-65 Mo-99 Ce-141 Ce-144 C-14 TOTAL FOR PERIOD Ci N/A N/A Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 9.30E-01 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 1.32E-02 Ci N/A N/A 9.30E-01 1.32E-02
TABLE IC Attachment I Page 5 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 GASEOUS EFFLUENTS-GROUND LEVEL RELEASES CONTINUOUS MODE BATCH MODE I
SURRY POWER STATION UNITS 1&2 1. FISSION & ACTIVATION GASES Kr-85 Kr-85m Kr-87 Kr-88 Xe-133 Xe-135 I
e-135m Xe-1318 Xe-131m I Xe-133m At-41 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci FIRST SECOND FIRST SECOND QUARTER QUARTER QUARTER QUARTER N/D N/D N/D N/D N/D 8.19E-05 N/D N/D N/D N/D N/D N/D N/D N/D 3.68E-05 N/D 2.11E-04 3.12E-05 NID N/D N/D 4.64E-04 7.43E-04 N/D N/D N/D N/D 7.95E-03 9.2 1E-04 N/D N/D N/D N/D N/D 8.87E-03 N/D N/D N/D N/D 1.44E-02 5.7 1E-03 1.97E-03 N/D N/D N/D 7.41E-03 2.95E-02 TOTAL FOR PERIOD
- 2. IODINES I
1-131 1-132 1-135 I
TOTAL FOR PERIOD I
- 3. PARTICULATES Sr-89 I
CSr-90 Cs-134 Cs-13 7 I
Ba-140 La-140 Co-58 I
Co-60 Mn-54 Fe-59 Zn-65 Mo-99 Ce-141 Ce-144 I
C-14 TOTAL FOR PERIOD Ci 8.19E-05 Ci 1.30E-05 Ci Ci N/D N/D Ci 1.30E-05 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D N/D N/D 4.59E-06 N/D N/D N/D N/D N/D N/D N/D 1.86E-03 6.20E-06 N/D N/D 6.20E-06 N/D N/D N/D N/D N/D N/D 1.09E-05 N/D N/D NiD N/D N/D N/D N/D 1.69E-02 N/D N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 2.02E-0 1 6.16E-09 N/D N/D 6.16E-09 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 6.71 E-01 Ci 1.86E-03 1.69E-02 2.2-167E0 2.02E-0 1 6.7 1 E-0 I
TABLE IC Page 6 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 GASEOUS EFFLUENTS-GROUND LEVEL RELEASES CONTINUOUS MODE BATCH MODE SURRY POWER STATION UNITS 1&2
Xe-135m Xe-138 Xe-131m I
Xe-133m Ar-41 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci THIRD FOURTH THIRD FOURTH QUARTER QUARTER QUARTER QUARTER N/D N/D N/D N/D 4.08E-05 1.49E-04 2.53E-05 N/D N/D N/D NID N/D N/D N/D N/D 4.8 1E-05 2.14E-04 4.46E-05 N/D N/D N/D N/D 3.07E-04 5.19E-02 N/D N/D N/D 1.8 1E-03 1.48E-03 N/D NID N/D N/D N/D 5.52E-02 N/D N/D N/D N/D N/D 1.49E-03 N/D N/D N/D N/D N/D 1.49E-03
,TOTAL FOR PERIOD
- 2. IODINES S 1-131 1-133 1-135 I
TOTAL FOR PERIOD I
- 3. PARTICULATES Sr-89 I
Sr-90 Cs-134 Cs-13 7 SBa-140 La-140 Co-58 I
Co-60 Mn-54 Fe-59 Zn-65 Mo-99 Ce-141 Ce-144 I
C-14 TOTAL FOR PERIOD Ci 2.15E-04 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/A N/D N/D N/D NiD N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 4.90E-03 N/D N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 6.97E-03 N/D N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 1.26E+00 NID N/D N/D N/A N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 3.39E-02 Ci 4.90E-03 6.97E-03 12E+O 33E0 1.26E+00 3.39E-02
Attachment I TABLE2A Page 7 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES I
SURRY POWER STATION UNITS 1&2 UNIT FIRST SECOND
% EST. ERROR QUARTER QUARTER A. FISSION AND ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING T RITIUM, GASES, ALPHA)
Ci 9.37E-03 7.25E-03 2.OOE+01
- 2. AVE DIL. CONC. DURING PERIOD giCi/mL 1.44E-1 I 1.28E-11
- 3. PERCENT OF APPLICABLE LIMIT 1.61E-05 1.33E-05 B. TRITIUM
- 1. TOTAL RELEASE Ci 3.10E+02 2.30E+02 2.OOE+01
- 2. AVE DIL. CONC. DURING PERIOD jiCi/mL 4.75E-07 4.07E-07
- 3. PERCENT OF APPLICABLE LIMIT 4.75E-03 4.07E-03 I C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE Ci N/D 4.62E-05 2.OOE+01
- 2. AVE DIL. CONC. DURING PERIOD giCi/mL N/A 8.17E-14
- 3. PERCENT OF APPLICABLE LIMIT N/A 4.08E-08 D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE Ci N/D N/D 2.00E+01 IE. VOLUME OF WASTE RELEASED (PRIOR TO DILUTION)
LITERS 3.28E+07 3.49E+07 3.OOE+00 F. VOLUME OF DILUTION WATER USED DURING PERIOD LITERS 6.51E+ 11 5.66E+1 I 3.OOE+00 I
TABLE 2A Attachment I Page 8 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SURRY POWER STATION UNITS 1&2 I A. FISSION AND ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
- 2. AVE DIL. CONC. DURING PERIOD
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE
- 2. AVE DIL. CONC. DURING PERIOD
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE 2, AVE DIL. CONC. DURING PERIOD
- 3. PERCENT OF APPLICABLE LIMIT I D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE IE. VOLUME OF WASTE RELEASED (PRIOR TO DILUTION)
F. VOLUME OF DILUTION WATER IUSED DURING PERIOD UNIT Ci giCi/mL Ci giCi/mL Ci 1iCi/mL Ci LITERS LITERS THIRD QUARTER 2.46E-03 3.18 E-12 9.43E-06 3.56E+O I 4.60E-08 4.60E-04 N/D N/A N/A N/D 4.35E+07 7.74E+ 11 FOURTH QUARTER 5.39E-04 7.70E-13 4.99E-06 7.8 1E+O1 1.12E-07 1.12E-03 N/D N/A N/A N/D 2.76E+07 7.OOE+ 1I
% EST. ERROR 2.OOE+01 2.OOE+O I 2.OOE+01 2.OOE+01 3.OOE+00 3.OOE+00
TABLE 2B Attachment I Page 9 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 LIQUID EFFLUENTS SURRY POWER STATION UNITS 1&2 CONTINUOUS MODE UNIT FIRST SECOND QUARTER QUARTER BATCH MODE FIRST SECOND QUARTER QUARTER Sr-89 Sr-90 Fe-55 Cs-134 Cs-137 1-131 Co-58 Co-60 Fe-59 Zn-65 Mn-54 Cr-51 Zr-95 Nb-95 Mo-99 Tc-99m Ba-140 La-140 Ce-141 Ce-144 Sb-124 Sb-125 Co-57 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D 2.37E-04 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 3.75E-04 6.9 1E-06 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 3.82E-04 N/D N/D N/D N/D N/D N/D 1.38E-05 N/D 6.19E-03 1.31E-03 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 7.23E-06 1.60E-03 9.40E-06 9.131E-03 N/D N/D N/D N/D N/D N/D 1.18E-04 N/D 1.79E-03 3.85E-04 N/D N/D N/D 3.88E-03 N/D N/D N/D N/D N/D N/D N/D N/D 2.39E-05 6.69E-04 N/D 6.87E-03 4.62E-05 N/D TOTAL FOR PERIOD Ci 2.37E-04 Xe-133 Xe-135 Ci Ci N/D N/D TOTAL FOR PERIOD Ci N/A N/A N/A 4.62E-05
TABLE 2B Attachment I Page 10 of 12 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD: 1/1/11 TO 12/31/11 LIQUID EFFLUENTS SURRY POWER STATION UNITS 1&2 CONTINUOUS MODE UNIT THIRD FOURTH QUARTER QUARTER BATCH MODE THIRD FOURTH QUARTER QUARTER Sr-89 Sr-90 Fe-55 Cs-134 Cs-137 1-131 Co-58 Co-60 Fe-59 Zn-65 Mn-54 Cr-51 Zr-95 Nb-95 Mo-99 Tc-99m Ba-140 La-140 Ce-141 Ce-144 Sb-124 Sb-125 Co-57 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci N/D N/D N/D N/D 4.57E-04 N/D N/D N/D NID N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 2.45E-04 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 2.45E-04 N/D N/D N/D N/D N/D N/D 9.50E-05 N/D 8.38E-04 3.77E-04 N/D N/D N/D 4.55E-04 N/D N/D N/D N/D N/D N/D N/D N/D 5.55E-06 2.29E-04 N/D 2.OOE-03 N/D N/D N/D N/D NID N/D 7.54E-05 N/D 8.67E-05 6.69E-05 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 6.48E-05 N/D 2.94E-04 N/D N/D Ci N/D Ci 4.57E-04 TOTAL FOR PERIOD Xe-133 Xe-135 Ci Ci N/D N/D TOTAL FOR PERIOD Ci N/A N/A N/A N/A
Attachment I Page 11 of 12 TABLE 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD: 1/1/11 - 12/31/11 SURRY POWER STATION A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 1. Type of waste 12 month Period Est. Total Error, %
- a. Spent resins, filter sludges, evaporator m3 1.63E+01 Note 1 1.00E+01 bottoms, etc.
Ci 2.77E+02 3.OOE+01
- b. Dry compressible waste, contaminated m3 5.26E+02 Note 2 1.OOE+01 equip., etc.
Ci 1.08E+00 3.OOE+01
- c. Irradiated components, control m3 O.OOE+O0 1.00E+01 rods, etc.
Ci O.OOE+00 3.OOE+01
- d. Other (Waste oil) m3 O.OOE+00 1.00E+01 Ci O.OOE+00 3.OOE+O1
- 2. Estimate of major nuclide composition (by type of waste)
- b. Co-60 Ni-63 Cs-137 Fe-55 Co-58 Mn-54 Sb-125 5.40E+O I 3.09E+O 1 8.01E+00 1.77E+00 1.75E+00 1.24E+00 4.39E+01 2.62E+01 1.34E+01 1.16E+O1 1.69E+00 1.15E+00 1.02E+00 C.
d.
Attachment I Page 12 of 12 TABLE 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT I SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD: 1/1/11 - 12/31/11 CONTINUED ISURRY POWER STATION A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 3. Solid Waste Disposition Number of Shipments 17 1
Mode of Transportation Truck Truck Destination Oak Ridge, TN (EnergySolutions)
Erwin, TN (Studsvik)
IRRADIATED FUEL SHIPMENT (Disposition)
Number of Shipments 0
Mode of Transportation Destination NOTE 1: Some of this waste was shipped to licensed waste processors for processing and/or volume reduction. Therefore, this volume is not representative of the actual volume buried. The total volume buried for this reporting period is 2.11 E-01 mi3.
I NOTE 2: Some DAW was shipped to licensed waste processors for processing and/or volume reduction. Therefore, this volume is not representative of the actual volume buried. The total volume buried for this reporting period is 2.26E+02 m3.
Page 1 of I ANNUAL AND QUARTERLY DOSES An assessment of radiation doses to the maximum exposed member of the public due to radioactive liquid and gaseous effluents released from the site for each calendar quarter for the calendar year of this report, along with an annual total of each effluent pathway is made pursuant to the ODCM, Section 6.7.2, requirement.
LIQUID GASEOUS 2011 Total Body GI-LLI Liver Gamma Beta Bone (mrem)
(mrem)
(mrem)
(mrad)
(mrad)
(mrem) 1st Quarter 6.91E-05 1.39E-04 6.48E-05 1.06E-05 2.44E-05 5.66E-02 2nd Quarter 6.47E-05 9.49E-05 6.45E-05 1.86E-04 1.13E-04 1.02E-01 3rd Quarter 9.75E-06 1.96E-05 1.02E-05 9.22E-06 2.04E-04 1.OOE-01 4th Quarter 1.58E-05 1.61E-05 1.65E-05 6.55E-06 8.15E-06 5.33E-03 Annual 1.59E-04 2.70E-04 1.56E-04 2.12E-04 3.50E-04 2.64E-01 Page 1 of I REVISIONS TO OFFSITE DOSE CALCULATION MANUAL (ODCM)
As required by Technical Specification 6.8.B, revisions to the ODCM, effective for the time period covered by this report, are included with this attachment. There were no revisions to the ODCM implemented during this reporting period.
Page I of I MAJOR CHANGES TO RADIOACTIVE LIQUID.
GASEOUS AND SOLID WASTE TREATMENT SYSTEMS There were no major changes to the radioactive liquid, gaseous or solid waste treatment systems for this reporting period.
PageIofI INOPERABILITY OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENT MONITORING INSTRUMENTATION I
The Annual Radioactive Effluent Release Report shall explain why monitoring instrumentation Irequired by the ODCM Attachments 1 and 5, which were determined to be inoperable, were not returned to operable status within 30 days. One component of the above referenced instrumentation Iwas inoperable greater than 30 days during this reporting period.
One of the two Unit #1 condenser air ejector exhaust flow rate indicators, I-VP-FI-I A, was out Lf service from 1/10/2011 to 3/10/2011. During routine Unit #1 Turbine Building rounds, Operations iscovered the flow indicator contained water that impaired the flow indicator from performing its function. An Engineering review of this issue determined that the flow indicator did not have a drain o remove water accumulation. Design Change SU-1 1-01029-000 was generated to install a drain on the
-VP-FI-i A, 1-VP-FI-i B and also the Unit #2 flow rate indicators. 1-VP-FL-i A was returned to
( ervice on 3/10/2011 upon completion of the drain valve installation.
Page 1 of I UNPLANNED RELEASES There were no unplanned liquid or unplanned gaseous releases during this reporting period.
Page 1 of I LOWER LIMIT OF DETECTION (LLD) FOR EFFLUENT SAMPLE ANALYSIS GASEOUS:
Isotope Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Xe-135m Xe-138 1-131 1-133 Sr-89 Sr-90 Cs-134 Cs-137 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Ce-141 Ce-144 Alpha Tritium Sr-89 Sr-90 Cs-134 Cs-137 1-131 Co-58 Co-60 Fe-59 Zn-65 Mn-54 Mo-99 Ce-141 Ce-144 Fe-55 Alpha Tritium Xe-133 Xe-135 Xe-133m Xe-135m Xe-138 Kr-87 Kr-88 Required LLD 1.OOE-04 1.OOE-04 1.OOE-04 1.OOE-04 l.OOE-04 1.OOE-04 1.OOE-04 l.OOE-12 1.OOE-10 1.OOE-1 1 1.OOE-1 1 1.OOE-I 1 1.OOE-11 1.OOE-1 1 1.OOE-11 1.OOE-I I 1.OOE-I I 1.OOE-I I 1.OOE-I1 1.OOE-I 1 1.OOE-I1 1.OOE-1I L.OOE-06 Typical LLD 2.16E-08 1.71E-05 1.98E 2.15E-05 1.15E 2.21E-05 3.95E 4.06E-05 5.32E 6.67E-06 2.93E-07
- 6.65E-05 6.04E-07
- 9.90E-05 5.98E-14
- 4.06E-13 1.1OE-12
- 4.06E-I 1 1.28E 5.31E-12 1.52E-15
- 5.83E-13 4.06E-14
- 4.01E-13 2.24E 6.83E-13 4.98E-14
- 4.44E-13 8.63E-14
- 5.80E-12 3.17E-14
- 2.17E-13 6.75E-14
- 5.41E-13 8.39E 7.11E-13 2.49E 4.06E-12 4.36E 3.97E-13 1.89E 1.60E-12 1.70E 1.71E-14 6.38E 6.38E-08 LIQUID:
5.OOE-08 5.OOE-08 5.OOE-07 5.OOE-07 1.OOE-06 5.OOE-07 5.OOE-07 5.OOE-07 5.OOE-07 5.OOE-07 5.OOE-07 5.OOE-07 5.OOE-07 1.OOE-06 1.OOE-07 1.OOE-05 1.OOE-05 1.OOE-05 1.OOE-05 1.OOE-05 1.OOE-05 1.OOE-05 1.OOE-05 2.03E-08 3.3 1E-09 7.99E-09 3.02E-09 7.63E-09 6.23E-09 1.13E-08 1.37E-08 1.34E-08 8.93E-09 3.82E-08 9.85E-09 4.37E-08 3.16E-07 2.84E-08 1.58E-06 1.81E-08 7.59E-09 5.67E-08 3.95E-07 8.60E-07 2.97E-08 2.88E-08
- 4.94E-08
- 8.14E-09
- 7.13E-08
- 4.86E-08
- 4.93E-08
- 4.97E-08
- 9.47E-08 1.08E-07 1.38E-07
- 6.52E-08
- 4.95E-07
- 6.86E-08
- 3.47E-07
- 9.22E-07
- 2.89E-08 1.58E-06
- 8.72E-07 5.17E-08 3.81E-07 3.40E-06 8.15E-06 1.70E-07 1.19E-07 Page 1 of 2 INDUSTRY GROUND WATER PROTECTION INITIATIVE The following is a summary of 2011 sample analyses of ground water monitoring wells that are not a part of the Radiological Environmental Monitoring Program (REMP). Analyses are performed by an independent laboratory.
Well Sample Tritium Gamma Fe-55 Ni-63 Sr-90 TRU Designation Date pCi/Liter pCi/Liter pCi/Liter pCi/Liter pCi/Liter pCi/Liter l-PL-Piez-04 2/16/11
<577 ND NA NA NA NA l-PL-Piez-05 2/15/11 13,400 ND
<85.9
<4.58
<0.505 NA I-PL-Piez-06 2/15/11 2,510 ND
<64.2
<4.68
<0.660 NA 1-PL-Piez-07 2/15/11
<568 ND NA NA NA NA 1-PL-Piez-27 2/15/11
<569 ND NA NA NA NA 1-PL-Piez-29 2/16/11 8,900 ND
<110
<4.67
<0.527 NA 1-PL-Piez-33 2/15/11
<575 ND NA NA NA NA 1-PL-Piez-34 2/15/11
<564 ND NA NA NA NA 1-PL-Piez-41 2/15/11
<558 ND NA NA NA NA 1-PL-Piez-42 2/16/11
<579 ND NA NA NA NA 1-PL-Piez-03 6/2/11
<840 NA NA NA NA NA 1-PL-Piez-04 6/1/11
<829 ND NA NA NA NA 1 -PL-Piez-05 5/24/11 10,800 ND NA NA NA NA 1-PL-Piez-06 5/24/11 3,450 ND NA NA NA NA 1-PL-Piez-07 5/31/11
<816 ND NA NA NA NA 1-PL-Piez-08 5/31/11
<860 ND NA NA NA NA 1-PL-Piez-09 6/1/11
<853 NA NA NA NA NA 1-PL-Piez-20 6/1/11
<799 ND NA NA NA NA 1-PL-Piez-22 5/31/11
<846 ND NA NA NA NA 1-PL-Piez-23 6/2/11
<870 ND NA NA NA NA 1-PL-Piez-24 6/1/11
<838 ND NA NA NA NA 1-PL-Piez-25 6/1/11
<811 ND NA NA NA NA 1-PL-Piez-27 5/31/11
<873 ND NA NA NA NA 1-PL-Piez-28 5/31/11
<874 ND NA NA NA NA 1-PL-Piez-29 5/24/11 7,780 ND NA NA NA NA 1-PL-Piez-33 5/31/11
<882 ND NA NA NA NA 1-PL-Piez-34 5/31/11
<871 ND NA NA NA NA 1-PL-Piez-35 6/1/11
<882 NA NA NA NA NA 1-PL-Piez-36 5/31/11
<821 NA NA NA NA NA 1-PL-Piez-37 6/2/11
<887 NA NA NA NA NA 1-PL-Piez-38 6/1/11
<866 NA NA NA NA NA l-PL-Piez-39 6/1/11
<877 NA NA NA NA NA 1-PL-Piez-40 6/1/11
<885 ND NA NA NA NA I-PL-Piez-41 5/31/11
<875 ND NA NA NA NA 1-PL-Piez-42 6/1/11
<745 ND NA NA NA NA ND = No non-natural gamma emitting nuclides detected when analyzed to REMP LLDs.
NA = Analysis not required. TRU = Transuranics (Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240 and Pu-241)
Page 2 of 2 INDUSTRY GROUND WATER PROTECTION INITIATIVE The following is a summary of 2011 sample analyses of ground water monitoring wells that are not a part of the Radiological Environmental Monitoring Program (REMP). Analyses are performed by an independent laboratory.
Well Sample Tritium Gamma Fe-55 Ni-63 Sr-90 TRU Designation Date pCi/Liter pCi/Liter pCi/Liter pCi/Liter pCi/Liter pCi/Liter I -PL-Piez-05 6/23/11 11,700 NA NA NA NA NA 1 -PL-Piez-06 6/23/11 2,120 NA NA NA NA NA 1-PL-Piez-29 6/23/11 8,520 NA NA NA NA NA 1-PL-Piez-05 7/28/11 8,360 NA NA NA NA NA 1-PL-Piez-06 7/28/11 2,020 NA NA NA NA NA 1-PL-Piez-29 7/29/11 7,080 NA NA NA NA NA 1 -PL-Piez-04 8/24/11
<999 ND NA NA NA NA 1-PL-Piez-05 8/24/11 11,500 ND NA NA NA NA l-PL-Piez-06 8/24/11 1,740 ND NA NA NA NA 1-PL-Piez-07 8/25/11
<997 ND NA NA NA NA 1-PL-Piez-08 8/25/11
<1,010 ND NA NA NA NA 1-PL-Piez-24 8/24/11
<1,010 ND NA NA NA NA I -PL-Piez-25 8/24/11
<1,000 ND NA NA NA NA 1-PL-Piez-27 8/25/11
<998 ND NA NA NA NA 1-PL-Piez-29 8/24/11 8,320 ND NA NA NA NA l-PL-Piez-33 8/24/11
<994 ND NA NA NA NA 1-PL-Piez-34 8/24/11
<995 ND NA NA NA NA I -PL-Piez-41 8/24/11
<995 ND NA NA NA NA 1-PL-Piez-42 8/24/11
<1,000 ND NA NA NA NA 1-PL-Piez-04 12/7/11
<1,030 ND NA NA NA NA 1-PL-Piez-05 12/6/11 9,920 ND NA NA NA NA 1-PL-Piez-06 12/7/11 2,500 ND NA NA NA NA I -PL-Piez-07 12/6/11
<1,030 ND NA NA NA NA 1-PL-Piez-27 12/6/11
<1,020 ND NA NA NA NA 1-PL-Piez-29 12/6/11 7,300 ND NA NA NA ND 1-PL-Piez-33 12/7/11
<1,040 ND NA NA NA ND 1 -PL-Piez-34 12/7/11
<1,020 ND NA NA NA ND 1 -PL-Piez-40 12/7/11
<1,030 ND NA NA NA ND 1 -PL-Piez-41 12/7/11
<1,020 ND NA NA NA ND l-PL-Piez-42 12/7/11
<1,020 ND NA NA NA ND ND = No non-natural gamma emitting nuclides detected when analyzed to REMP LLDs.
NA = Analysis not required. TRU = Transuranics (Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240 and Pu-241)