ML11326A159
| ML11326A159 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 11/10/2011 |
| From: | Susquehanna |
| To: | Gerlach R Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 028401, 2011-63589 | |
| Download: ML11326A159 (30) | |
Text
Nov.
10, 2011 Page 1
of 2
MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2011-63589 USER INFORMATION:
GERLACH*ROSE M EMPL#:028401 CA#:
0363 Address: NUCSA2 Phone#:
254-3194 TRANSMITTAL INFORMATION:
TO:
GERLACH*ROSE M 11/10/2011 LOCATION:
USNRC FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.
HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.
TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.
ATTENTION:
"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.
TSBI -
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 03/01/2011 ADD MANUAL TABLE OF CONTENTS DATE: 11/09/2011 CATEGORY:
DOCUMENTS TYPE: TSB1 Aool
Nov.
10, 2011 Page 2
of 2
ID:
TEXT 3.6.1.1 REMOVE:
REV:3 ADD:
REV: 4 CATEGORY:
DOCUMENTS TYPE: TSB1 ID:
TEXT LOES REMOVE:
REV:101 ADD:
REV: 102 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.
UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUAL
- USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
SSES MANTJA-L Manual Name:
TSBI Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents Issue Date:
11/09/2011 Procedure Name Rev TEXT LOES 102
Title:
LIST OF EFFECTIVE SECTIONS Issue Date 11/09/2011 Change ID Change Number TEXT TOC
Title:
TABLE OF.CONTENTS 20 09/01/2010 TEXT 2.1.1 5
Title:
SAFETY LIMITS (SLS)
REACTOR TEXT 2.1.2 1
Title:
SAFETY LIMITS (SLS)
REACTOR 05/06/2009 CORE SLS
/
10/04/2007 COOLANT SYSTEM,,(RCS)
PRESSURE S TEXT 3.0 3
08/20/2009'
Title:
LIMITING CONDITION FOR OPERATION,(LCO) APPLICABILITY TEXT. 3.1.1
Title:
REACTIVITY TEXT 3.1.2
Title:
REACTIVITY
/
TEXT 3.1.3
Title:
REACTIVITY TEXT 3.1.4
Title:
REACTIVITY TEXT 3.1.5
Title:
REACTIVITY TEXT 3.1.6
Title:
REACTIVITY
<.,0 4 /04/18/2006 CONTROL-SYSTEMS SHUTDOWN MARGIN (SDM)
.0 11/15/2002 CONTROL SYSTEMS REACTIVITY ANOMALIES 2
01/19/2009
'CONTROL SYSTEMS CONTROL ROD OPERABILITY 4
01/30/2009 CONTROL SYSTEMS CONTROL ROD SCRAM TIMES 1
07/06/2005 CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS 2
04/18/2006 CONTROL SYSTEMS ROD PATTERN CONTROL Pagel of 8
Report Date: 11/09/11 Page 1 of
.8 Report Date: 11/09/11
SSES MANUAL.
Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.1. 7
Title:
REACTIVITY CONTROL 3
04/23/2008 SYSTEMS STANDBY LIQUID CONTROL (SLC)
SYSTEM TEXT 3.1.8 3
05/06/2009
Title:
REACTIVITY CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV)
VENT AND DRAIN VALVES TEXT 3.2.1 2
04/23/2008
Title:
POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
TEXT 3.2.2
Title:
POWER DISTRIBUTION 3
05/06/2009 LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)
TEXT 3.2.3 2
04/23/2008
Title:
POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)
TEXT 3.3.1.1 4
04/23/2008
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)
INSTRUMENTATION 0
TEXT 3.3.1.2
Title:
INSTRUMENTATION 2
01/19/2009 SOURCE RANGE MONITOR (SRM)
INSTRUMENTATION TEXT 3.3.2.1 3
04/23/2008
Title:
INSTRUMENTATION CONTROL ROD'BLOCK INSTRUMENTATION TEXT 3.3.2.2 2
04/05/2010
Title:
INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1.
Title:
INSTRUMENTATION TEXT 3.3.3.2
Title:
INSTRUMENTATION TEXT 3.3.4.1
Title:
INSTRUMENTATION 8.
10/27/2008 POST ACCIDENT MONITORING (PAM)
INSTRUMENTATION 1
04/18/2005 REMOTE SHUTDOWN SYSTEM 1
04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)
INSTRUMENTATIONU Page2 of 8
Report Date: 11/09/11 Page 2 of 8
Report Date: 11/09/11
SSES MANUAL Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.4.2 0
11/15/2002
Title:
INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)
INSTRUMENTATION TEXT 3.3.5.1 3
08/20/2009
Title:
INSTRUMENTATION EMERGENCY CORE COOLING SYSTEM (ECCS)
INSTRUMENTATION TEXT 3.3.5.2
-0 11/15/2002
Title:
INSTRUMENTATION REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION TEXT 3.3.6.1 4
04/23/2008
Title:
INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 4
09/01/2010
Title:
INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION p
TEXT 3.3.7.1 2
10/27/2008
Title:
INSTRUMENTATION CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEM INSTRUMENTATION TEXT 3.3.8.1 2
12/17/2007
Title:
INSTRUMENTATION LOSS OF POWER (LOP)
INSTRUMENTATION TEXT 3.3.8.2 0
11/15/2002
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)
ELECTRIC POWER MONITORING TEXT 3.4.1 4
04/27/2010
Title:
RECIRCULATION LOOPS OPERATING TEXT 3.4.2 2
04/27/2010
Title:
JET PUMPS TEXT 3.4.3 2
04/23/2008
Title:
REACTOR COOLANT SYSTEM RCS SAFETY RELIEF VALVES S/RVS TEXT 3.4.4 0
11/15/2002
Title:
RCS OPERATIONAL LEAKAGE Page 1 of 8
Report Date: 11/09./11
SSES MANUAL Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.4.5 1
01/16/2006
Title:
RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 3
01/25/2011
Title:
RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2
10/04/2007
Title:
RCS SPECIFIC ACTIVITY TEXT 3.4.8
Title:
REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9
Title:
REACTOR COOLANT COLD SHUTDOWN 1
04/18/2005 SYSTEM (RCS)
SHUTDOWN COOLING SYSTEM 0
11/15/2002 SYSTEM (RCS)
SHUTDOWN COOLING SYSTEM TEXT 3.4.10 3
04/23/2008
Title:
RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.11 0
11/15/2002
Title:
REACTOR COOLANT SYSTEM (RCS). REACTOR STEAM DOME PRESSURE TEXT 3.5.1 2
01/16/2006
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR CORE ISOLATION SYSTEM ECCS OPERATING TEXT 3.5.2 0
11/15/2002
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR CORE ISOLATION SYSTEM ECCS -
SHUTDOWN TEXT 3.5.3 2
07/09/2010
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR CORE ISOLATION SYSTEM RCIC SYSTEM COOLING (RCIC)
COOLING (RCIC)
COOLING (RCIC)
TEXT 3.6.1.1
Title:
11/09/2011 TEXT 3.6.1.2 1
04/23/2008
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK Page4 of 8 Report Date: 11/09/11 Page 4 of 8
Report Date: 11/09/11
SSES MA.NUJAL O
Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.1.3 9
04/14/2010
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)
LDCN 3092 TEXT 3.6.1.4 1
04/23/2008
Title:
CONTAINMENT SYSTEMS CONTAINMENT PRESSURE TEXT 3.6.1.5 1
10/05/2005
Title:
CONTAINMENT SYSTEMS DRYWELL AIR TEMPERATURE TEXT 3.6.1.6 0
11/15/2002
Title:
CONTAINMENT SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS TEXT 3.6.2.1 2
04/23/2008
Title:
CONTAINMENT SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE I
TEXT 3.6.2.2 0
11/15/2002
Title:
CONTAINMENT SYSTEMS SUPPRESSION POOL WATER LEVEL TEXT 3.6.2.3 1
01/16/2006
Title:
CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL COOLING TEXT 3.6.2.4 0
11/15/2002
Title:
CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL SPRAY TEXT 3.6.3.1 2
06/13/2006
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS TEXT 3.6.3.2 1
04/18/2005
Title:
CONTAINMENT SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.3.3 0
11/15/2002
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 7
10/04/2007
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT Page 5 of.8 Report Date: 11/09/11
SSES MANUAIL Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.4.2 3
03/10/2010
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)
TEXT 3.6.4.3 4
09/21/2006
Title:
CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)
SYSTEM TEXT 3.7.1
Title:
PLANT SYSTEMS ULTIMATE HEAT 4
04/05/2010 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)
SYSTEM AND THE SINK (UHS)
TEXT 3.7.2
Title:
PLANT TEXT 3.7.3
Title:
PLANT TEXT 3.7.4
Title:
PLANT TEXT 3.7.5
Title:
PLANT TEXT 3.7.6
Title:
PLANT TEXT 3.7.7
Title:
PLANT 2
02/11/2009 SYSTEMS EMERGENCY SERVICE WATER (ESW)
SYSTEM 1
01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEM 0
11/15/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1
10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS 2
04/23/2008 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1
10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL TEXT 3.7.8
Title:
PLANT SYSTEMS 0
04/23/2008 TEXT 3.8.1 6
05/06/2009
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
OPERATING TEXT 3.8.2 0
11/15/2002
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
SHUTDOWN Page6 of 8 Report Date: 11/09/11 Page 6, of 8
Report Date: 11/09/11
SSES M.A.NUAL Manual Name:
TSBl Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.3
Title:
ELECTRICAL TEXT 3.8.4
Title:
ELECTRICAL TEXT 3.8.5
Title:
ELECTRICAL TEXT 3.8.6
Title:
ELECTRICAL TEXT 3.8.7
Title:
ELECTRICAL TEXT 3.8.8
Title:
ELECTRICAL TEXT 3.9.1
Title:
REFUELING TEXT 3.9.2
Title:
REFUELING TEXT 3.9.3
Title:
REFUELING 2
POWER SYSTEMS 04/14/2010 DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3
01/19/2009 POWER SYSTEMS DC SOURCES -
OPERATING 1
12/14/2006 POWER SYSTEMS DC SOURCES -
SHUTDOWN POWER SYST POWER SYST POWER SYST
)PERATIONS
)PERATIONS
)PERATIONS 1
12/14/2006
'EMS BATTERY CELL PARAMETERS 1
10/05/2005
'EMS DISTRIBUTION SYSTEMS -
OPERATING 0
11/15/2002
'EMS DISTRIBUTION SYSTEMS -
SHUTDOWN 0
11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1
09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0
11/15/2.002 CONTROL ROD POSITION TEXT 3.9.4
Title:
REFUELING TEXT 3.9.5
Title:
REFUELING TEXT 3.9.6
Title:
REFUELING 0
11/15/2002 OPERATIONS CONTROL ROD POSITION INDICATION OPERATIONS OPERATIONS 0
11/15/2002 CONTROL ROD OPERABILITY -
REFUELING 1
10/04/2007 REACTOR PRESSURE VESSEL (RPV)
WATER LEVEL Page7 of 8
Report Date: 11/09/11 Page 7 of 8
Report Date: 11/09/11
SSES MANUAL Manual Name:
TSBI Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.9.7 0
11/15/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)
HIGH WATER LEVEL TEXT 3.9.8 0
11/15/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)
LOW WATER LEVEL TEXT 3.10.1
Title:
SPECIAL TEXT 3.10.2
Title:
SPECIAL TEXT 3.10.3
Title:
SPECIAL TEXT 3.10.4
Title:
SPECIAL TEXT 3.10.5
Title:
SPECIAL TEXT 3.10.6
Title:
SPECIAL TEXT 3.10.7
Title:
SPECIAL TEXT 3.10.8
Title:
SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1
01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0
11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0
11/15/2002 SINGLE CONTROL ROD WITHDRAWAL -
HOT SHUTDOWN 0
11/15/2002 SINGLE CONTROL ROD WITHDRAWAL -
COLD SHUTDOWN 0
11/15/2002 SINGLE CONTROL ROD DRIVE (CRD)
REMOVAL -
REFUELING 0
11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL REFUELING 1
04/18/20.06 CONTROL ROD TESTING -
OPERATING 1
04/12/2006 SHUTDOWN MARGIN (SDM)
TEST -
REFUELING Page8 of 8 Report Date: 11/09/11 Page 8 of 8
Report Date: 11/09/11
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision TOC Table of Contents 20 B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0
Page TS / B 2.0-2 3
Page TS / B 2.0-3 5
Page TS/ B 2.0-4 3
Page TS / B 2.0-5 5
Page TS / B 2.0-6 1
Pages TS / B 2.0-7 through TS / B 2.0-9 1
B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1
Pages TS / B 3.0-2 through TS / B 3.0-4 0
Pages TS / B 3.0-5 through TS / B 3.0-7 1
Page TS / B 3.0-8 3
Pages TS / B 3.0-9 through TS / B 3.0-11 2
Page TS / B 3.0-11 a 0
Page TS / B 3.0-12 1
Pages TS / B 3.0-13 through TS / 83.0-15 2
Pages TS / B 3.0-16 and TS / B 3.0-17 0
B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0
Page TS / B 3.1-5 1
Pages TS / B 3.1-6 and TS / B 3.1-7 2
Pages B 3.1-8 through B 3.1-13 0
Page TS / B 3.1-14 1
Page B 3.1-15 0
Page TS / B 3.1-16 1
Pages B 3.1-17 through B 3.1-19 0
Pages TS / B 3.1-20 and TS / B 3.1-21 1
Page TS / B 3.1-22
,0 Page TS / B 3.1-23 1
Page TS / B 3.1-24 0
Pages TS / B 3.1-25 through TS / B 3.1-27, 1
Page TS / B 3.1-28 2
Page TS / B 3.1-29 1
Pages B 3.1-30 through B 3.1-33 0
Pages TS / B 3.3-34 through TS / B 3.3-36 1
Pages TS / B 3.1-37 and TS / B 3.1-38 2
Pages TS / B 3.1-39 and TS / B 3.1-40 2
Page TS / B 3.1-40a 0
Pages TS / B 3.1-41 and TS / B 3.1-42 2
SUSQUEHANNA
- UNIT I TS / B LOES-1 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-1 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.1.43 1
Page TS / B 3.1-44 0
Page TS / B 3.1-45 3
Pages TS / B 3.1-46 through TS / B 3.1-49 1
Page TS / B 3.1-50 0
Page TS / B 3.1-51 3
B 3.2 POWER DISTRIBUTION LIMITS BASES Page TS / B 3.2-1 2
Pages TS / B 3.2-2 and TS / B 3.2-3 3
Pages TS / B 3.2-4 and TS / B 3.2-5 2
Page TS / B 3.2-6 3
Page B 3.2-7 1
Pages TS / B 3.2-8 and TS / B 3.2-9 3
Page TS / B 3.2.10 2
Page TS / B 3.2-11 3
Page TS / B 3.2-12 1
Page TS / B 3.2-13 2
B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1
Page TS / B 3.3-5 2
Page TS / B 3.3-6 1
Page TS / B 3.3-7 3
Page TS / B 3.3-7a 1
Page TS / B 3.3-8 4
Pages TS / B 3.3-9 through TS / B 3.3-12 3
Pages TS / B 3.3-12a 1
Pages TS / B 3.3-12b and TS / B 3.3-12c 0
Page TS / B 3.3-13 1
Page TS / B 3.3-14 3
Pages TS / B 3.3-15 and TS / B 3.3-16 1
Pages TS / B 3.3-17 and TS / B 3.3-18 4
Page TS / B 3.3-19 1
Pages TS / B 3.3-20 through TS / B 3.3-22 2
Page TS / B 3.3-22a 0
Pages TS / B 3.3-23 and TS / B 3.3-24 2
Pages TS / B 3.3-24a and TS / B 3.3-24b 0
Page TS / B 3.3-25 3
Page TS / B 3.3-26 2
Page TS / B 3.3-27 1
Pages TS / B 3.3-28 through TS I B 3.3-30 3
Page TS / B 3.3-30a 0
SUSQUEHANNA
- UNIT 1 TSIBLOES-2 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-2 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.3-31 4
Page TS / B 3.3-32 5
Pages TS / B 3.3-32a 0
Page TS / B 3.3-32b 1
Page TS / B 3.3-33 5
Page TS / B 3.3-33a 0
Page TS / B 3.3-34 1
Pages TS / B 3.3-35 and TS / B 3.3-36 2
Pages TS / B 3.3-37 and TS / B 3.3-38 1
Page TS / B 3.3-39 2
Pages TS / B 3.3-40 through TS / B 3.3-43 1
Page TS / B 3.3-44 4
Pages TS / B 3.3-44a and TS / B 3.3-44b 0
Page TS / B 3.3-45 3
Pages TS / B 3.3-45a and TS / B 3.3-45b 0
Page TS / B 3.3-46 3
Pages TS / B 3.3-47 2
Pages TS / B 3.3-48 through TS / B 3.3-51 3
Pages TS / B 3.3-52 and TS / B 3.3-53 2
Page TS / B 3-3-53a 0
Page TS / B 3.3-54 4
Page TS / B 3.3-55 2
Pages TS / B 3.3-56 and TS / B 3.3-57 1
Page TS / B 3.3-58 0
Page TS / B 3.3-59 1
Page TS / B 3.3-60 0
Page TS / B 3.3-61 1
Pages TS / B 3.3-62 and TS / B 3.3-63 0
Pages TS / B 3.3-64 and TS / B 3.3-65 2
Page TS / B 3.3-66 4
Page TS / B 3.3-67 3
Page TS / B 3.3-68 4
Page TS / B 3.3-69 5
Pages TS / B 3.3-70 4
Page TS / B 3.3-71 3
Pages TS / B 3.3-72 and TS / B 3.3-73 2
Page TS / B 3.3-74 3
Page TS / B 3.3-75 2
Page TS / B 3.3-75a 6
Page TS / B 3.3-75b 7
Page TS / B 3.3-75c 5
SUSQUEHANNA
- UNIT 1 TS/BLOES-3 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-3 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages B 3.3-76 through 3.3-77 0
Page TS / B 3.3-78 1
Pages B 3.3-79 through B 3.3-81 0
Page B 3.3-82 1
Page B 3.3-83 0
Pages B 3.3-84 and B 3.3-85 1
Page B 3.3-86 0
Page B 3.3-87 1
Page B 3.3-88 0
Page B 3.3-89 1
Page TS / B 3.3-90 1
Page B 3.3-91 0
Pages TS / B 3.3-92 through TS / B 3.3-100 1
Pages TS / B 3.3-101 through TS / B 3.3-103 0
Page TS / B 3.3-104 2
Pages TS / B 3.3-105 and TS / B 3.3-106 0
Page TS / B 3.3-107 1
Page TS / B 3.3-108 0
Page TS / B 3.3-109 1
Pages TS / B 3.3-110 and TS / B 3.3-111 0
Pages TS / B 3.3-112 and TS / B 3.3-112a 1
Pages TS / B 3.3-113 through TS / B 3.3-115 1
Page TS / B 3.3-116 3
Page TS / B 3.3-117 1
Pages TS / B 3.3-118 through TS / B 3.3-122 0
Pages TS / B 3.3-123 and TS / B 3.3-124 1
Page TS / B 3.3-124a 0
Page TS / B 3.3-125 0
Pages TS / B 3.3-126 and TS / B 3.3-127 1
Pages TS / B 3.3-128 through TS/ B 3.3-130 0
Page TS / B 3.3-131 1
Pages TS / B 3.3-132 through TS / B 3.3-134 0
Pages B 3.3-135 through B 3.3-137 0
Page TS / B 3.3-138 1
Pages B 3.3-139 through B 3.3-149 0
Pages TS / B 3.3-150 and TS / B 3.3-151 1
Pages TS / B 3.3-152 through TS / B 3.3-154 2
Page TS / B 3.3-155 1
Pages TS / B 3.3-156 through TS / B 3.3-158 2
Pages TS / B 3.3-159 through TS / B 3.3-162 1
Page TS / B 3.3-163 2
Pages TS / B 3.3-164 and TS / B 3.3-165 1
Pages TS / B 3.3-166 and TS / B 3.3-167 2
SUSQUEHANNA - UNIT 1 TS / B LOES-4 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.3-168 and TS / B 3.3-169 1
Page TS / B 3.3-170 2
Pages TS / B 3.3-171 through TS / B 3.3-177 1
Pages TS / B 3.3-178 through TS / B 3.3-179a 2
Pages TS / B 3.3-179b and TS / B 3.3-179c 0
Page TS / B 3.3-180 1
Page TS / B 3.3-181 3
Page TS / B 3.3-182 1
Page TS / B 3.3-183 2
Page TS / B 3.3-184 1
Page TS / B 3.3-185 4
Page TS / B 3.3-186 1
Pages TS / B 3.3-187 and TS / B 3.3-188 2
Pages TS / B 3.3-189 through TS / B 3.3-191 1
Page TS / B 3.3-192 0
Page TS / B 3.3-193 1
Pages TS / B.3.3-194 and TS / B 3.3-195 0
Page TS / B 3.3-196 2
Pages TS / B 3.3-197 through TS / B 3.3-204 0
Page TS / B 3.3-205 1
Pages B 3.3-206 through B 3.3-209 0
Page TS / B 3.3-210 1
Pages B 3.3-211 through B 3.3-219 0
B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0
Pages TS / B 3.4-3 and Page TS / B 3.4-4 4
Page TS / B 3.4-5 3
Pages TS / B 3.4-6 through TS / B 3.4-9 2
Page TS / B 3.4-10 1
Pages TS / 3.4-11 and TS / B 3.4-12 0
Page TS / B 3.4-13 1
Page TS / B 3.4-14 0
Page TS / B 3.4-15 2
Pages TS / B 3.4-16 and TS / B 3.4-17 3
Page TS / B 3.4-18 2
Pages B 3.4-19 through B 3.4-27 0
Pages TS / B 3.4-28 through TS / B 3.4-30 1
Page TS / B 3.4-31 0
Pages TS / B 3.4-32 and TS / B 3.4-33 1
Page TS / B 3.4-34 0
Pages TS / B 3.4-35 and TS / B 3.4-36 1
Page TS I B 3.4-37 2
Page TS / B 3.4-38 1
SUSQUEHANNA
- UNIT 1 TS I B LOES-5 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-5 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages B 3.4-39 and B 3.4-40 0
Page TS / B 3.4-41 1
Pages B 3.4-42 through B 3.4-48 0
Page TS / B 3.4-49 3
Page TS / B 3.4-50 1
Page TS / B 3.4-51 3
Page TS / B 3.4-52 2
Page TS / B 3.4-53 1
Pages TS / B 3.4-54 through TS / B 3.4-56 2
Page TS / B 3.4-57 3
Pages TS / B 3.4-58 through TS / B 3.4-60 1
B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0
Page TS / B 3.5-3 2
Page TS / B 3.5-4 1
Page TS / B 3.5-5 2
Page TS / B 3.5-6 1
Pages B 3.5-7 through B 3.5-10 0
Page TS / B 3.5-11 1
Page TS / B 3.5-12 0
Page TS / B 3.5-13 1
Pages TS / B 3.5-14 and TS / B 3.5-15 0
Pages TS / B 3.5-16 through TS / B 3.5-18 1
Pages B 3.5-19 through B 3.5-24 0
Page TS / B 3.5-25 through TS / B 3.5-27 1
Page TS / B 3.5-28 0
Page TS / B 3.5-29 1
Pages TS / B 3.5-30 and TS / B 3.5-31 0
B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2
Page TS / B 3.6-1a 3
Page TS / B 3.6-2 4
Page TS / B 3.6-3 3
Page TS / B 3.6-4 4
Pages TS / B 3.6-5 and TS / B 3.6-6 3
Page TS / B 3.6-6a 2
Page TS / B 3.6-6b 3
Page TS / B 3.6-6c 0
Page B 3.6-7 0
Page B 3.6-8 1
Pages B 3.6-9 through B 3.6-14 0
Page TS / B 3.6-15 2
Page TS / B 3.6-15a 0
Page TS / B 3.6-15b 2
SUSQUEHANNA - UNIT 1 TS / B LOES-6 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.6-16 and TS / B 3.6-17 1
Page TS / B 3.6-17a 0
Pages TS / B 3.6-18 and TS / B 3.6-19 0
Page TS / B 3.6-20 1
Page TS / B 3.6-21 2
Page TS / B 3.6-22 1
Page TS / B 3.6-22a 0
Page TS / B 3.6-23 1
Pages TS / B 3.6-24 and TS / B 3.6-25 0
Pages TS / B 3.6-26 and TS / B 3.6-27 2
Page TS / B 3.6-28 7
Page TS / B 3.6-29 2
Page TS I B 3.6-30 1
Page TS / B 3.6-31 3
Pages TS / B 3.6-32 and TS / B 3.6-33 1
Pages TS / B 3.6-34 and TS / B 3.6-35 0
Page TS / B 3.6-36 1
Page TS / B 3.6-37 0
Page TS / B 3.6-38 3
Page TS / B 3.6-39 2
Page TS / B 3.6-40 6
Page B 3.6-41 1
Pages B 3.6-42 and B 3.6-43 3
Pages TS / B 3.6-44 and TS / B 3.6-45 1
Page TS / B 3.6-46 2
Pages TS / B 3.6-47 through TS / B 3.6-51 1
Page TS / B 3.6-52 2
Pages TS / B 3.6-53 through TS / B 3.6-56 0
Page TS / B 3.6-57 1
Page TS / 3.6-58 2
Pages B 3.6-59 through B 3.6-63 0
Pages TS / B 3.6-64 and TS / B 3.6-65 1
Pages B 3.6-66 through B 3.6-69 0
Pages TS / B 3.6-70 through TS / B 3.6-72 1
Page TS / B 3.6-73 2
Pages TS / B 3.6-74 and TS / B 3.6-75 1
Pages B 3.6-76 and B 3.6-77 0
Page TS / B 3.6-78 1
Pages B 3.6-79 through B 3.3.6-83 0
Page TS / B 3.6-84 3
Page TS / B 3.6-85 2
Page TS / B 3.6-86 4
SUSQUEHANNA
- UNIT 1 TS/BLOES-7 Revision 102 SUSQUEHANNA - UNIT 1 TS I B LOES-7 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.6-87 through TS / B 3.6-88a 2
Page TS / B 3.6-89 4
Page TS / B 3.6-90 2
Page TS / B 3.6-91 3
Pages TS / B 3.6-92 through TS / B 3.6-96 1
Page TS / B 3.6-97 2
Pages TS / B 3.6-98 and TS / B 3.6-99 1
Page TS / B 3.6-100 3
Page TS / B 3.6-100a 0
Pages TS / B 3.6-101 and TS / B 3.6-102 1
Pages TS / B 3.6-103 and TS / B 3.6-104 2
Page TS / B 3.6-105 3
Page TS / B 3.6-106 2
Page TS / B 3.6-107 3
B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 3
Page TS / B 3.7-2 4
Pages TS / B 3.7-3 through TS / B 3.7-5 3
Page TS / B 3.7-5a 1
Page TS / B 3.7-6 3
Page TS / B 3.7-6a 2
Page TS / B 3.7-6b I
Page TS / B 3.7-6c 2
Page TS / B 3.7-7 3
Page TS / B 3.7-8 2
Pages TS / B 3.7-9 through TS / B 3.7-11 1
Pages TS / B 3.7-12 and TS / B 3.7-13 2
Pages TS / B 3.7-14 through TS / B 3.7-18 3
Page TS / B 3.7-18a 1
Pages TS / B 3.7-18b through TS / B 3.7-18e 0
Pages TS / B 3.7-1.9 through TS / B 3.7-23 1
Page TS / B 3.7-24 1
Pages TS / B 3.7-25 and TS / B 3.7-26 0
Pages TS / B 3.7-27 through TS / B 3.7-29 5
Page TS / B 3.7-30 2
Page TS / B 3.7-31 1
Page TS / B 3.7-32 0
Page TS / B 3.7-33 1
Pages TS / B 3.7-34 through TS / B 3.7-37 0
SUSQUEHANNA - UNIT 1 TS/B LOES-8 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-8 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 3
Pages TS / B 3.8-2 and TS / B 3.8-3.
2 Page TS / B 3.8-4 3
Pages TS / B 3.8-4a and TS I B 3.8-4b 0
Page TS / B 3.8-5 5
Page TS / B 3.8-6 3
Pages TS / B 3.8-7 through TS/B 3.8-8 2
Page TS / B 3.8-9 4
Page TS / B 3.8-10 3
Pages TS / B 3.8-11 and TS / B 3.8-17 2
Page TS / B 3.8-18 3
Pages TS / B 3.8-19 through TS / B 3.8-21 2
Pages TS / B 3.8-22 and TS / B 3.8-23 3
Pages TS / B 3.8-24 through TS / B 3.8-37 2
Pages B 3.8-38 through B 3.8-44 0
Page TS / B 3.8-45 1
Pages TS / B 3.8-46 through TS / B 3.8-48 0
Pages TS / B 3.8-49 through TS / B 3.8-51 1
Page TS / B 3.8-52 0
Page TS / B 3.8-53.
1 Pages TS I B 3.8-54 through TS / B 3.8-57 2
Pages TS / B 3.8-58 through TS / B 3.8-61 3
Pages TS / B 3.8-62 and TS / B 3.8-63 5
Page TS / B 3.8-64 4
Page TS / B 3.8-65 5
Pages TS / B 3.8-66 through TS / B 3.8-77 1
Pages TS / B 3.8-77A through TS / B 3.8-77C 0
Pages B 3.8-78 through B 3.8-80 0
Page TS / B 3.8-81 1
Pages B 3.8-82 through B 3.8-90 0
B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a 1
Pages TS / B 3.9-2 through TS / B 3.9-5 1
Pages TS / B 3.9-6 through TS / B 3.9-8 0
Pages B 3.9-9 through B 3.9-18 0
Pages TS / B 3.9-19 through TS / B 3.9-21 1
Pages B 3.9-22 through B 3.9-30 0
SUSQUEHANNA-UNITi TS/BLOES-9 Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-9 Revision 102
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2
Pages TS / B 3.10-2 through TS / B 3.10-5 1
Pages B 3.10-6 through B 3.10-31 0
Page TS / B 3.10-32 2
Page B 3.10-33 0
Page TS / B 3.10-34 1
Pages B 3.10-35 and B 3.10-36 0
Page TS / B 3.10-37 1
Page TS / B 3.10-38 2
TSBI Text LOES.doc 11/4/2011 SUSQUEHANNA - UNIT I TS I B LOES-lO Revision 102 SUSQUEHANNA - UNIT 1 TS / B LOES-10 Revision 102
PPL Rev. 4 Primary Containment B 3.6.1.1 B 3.6 CONTAINMENT SYSTEMS B 3.6.1.1 Primary Containment BASES BACKGROUND The function of the primary containment is to isolate and contain fission products released from the Reactor Primary System following a Design Basis Loss of Coolant Accident and to confine the postulated release of radioactive material. The primary containment consists of a steel lined, reinforced concrete vessel, which surrounds the Reactor Primary System and provides an essentially leak tight barrier against an uncontrolled release of radioactive material to the environment.
The isolation devices for the penetrations in the primary containment boundary are a part of the containment leak tight barrier. To maintain this leak tight barrier:
- a.
All penetrations required to be closed during accident conditions are either:
1..
capable of being closed by an OPERABLE automatic containment isolation system, or
- 2.
closed by manual valves, blind flanges, or de-activated automatic valves secured in their closed positions, except as provided in LCO 3.6.1.3, "Primary Containment Isolation Valves (PCIVs)";
- b.
The primary containment air lock is OPERABLE, except as provided in LCO 3.6.1.2, "Primary Containment Air Lock";
and
- c.
All equipment hatches are closed.
Several instruments connect to the primary containment atmosphere and are considered extensions of the primary containment. The leak rate tested instrument isolation valves identified in the Leakage Rate Test Program should be used as the primary containment boundary when the instruments are isolated and/or vented. Table B 3.6.1.1-1 contains the listing of the instruments and isolation valves.
(continued)
SUSQUEHANNA-UNIT 1 TS / B 3.6-1 Revision 2
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES BACKGROUND (continued)
The H20 2 Analyzer lines beyond the PCIVs, up to and including the components within the H20 2 Analyzer panels, are extensions of primary containment (i.e., closed system), and are required to be leak rate tested in accordance with the Leakage Rate Test Program. The H20 2 Analyzer closed system boundary is identified in the Leakage Rate Test Program, and consists of components, piping, tubing, fittings, and valves, which meet the design guidance of Reference 7. Within the H20 2 Analyzer panels, the boundary ends at the first normally closed valve. The closed system boundary between PASS and the H20 2 Analyzer system ends at the Seismic Category I boundary between the two systems. This boundary occurs at the process sampling solenoid operated isolation valves (SV-12361, SV-12365, SV-12366, SV-12368, and SV-12369). These solenoid operated isolation valves do not fully meet the guidance of Reference 7 for closed system boundary valves in that they are not powered from a Class 1 E power source. Based upon a risk determination, operating these valves as closed system boundary valves is not risk significant.
These normally closed valves are required to be leakage rate tested in accordance with the Leakage Rate Test Program, since they form part of the closed system boundary for the H20 2 Analyzers. These valves are "closed system boundary valves" and may be opened under administrative control, as delineated in Technical Requirements Manual (TRM) Bases 3.6.4. Opening of these valves to permit testing of PASS in Modes 1, 2, and 3 is permitted in accordance with TRO 3.6.4.
When the H20 2 Analyzer panels are isolated and/or vented, the panel isolation valves identified in the Leakage Rate Test Program should be used as the boundary of the extension of primary containment. Table B 3.6.1.1-2 contains a listing of the affected H20 2 Analyzer penetrations and panel isolation valves.
This Specification ensures that the performance of the primary containment, in the event of a Design Basis Accident (DBA),
meets the assumptions used in the safety analyses of References 1 and 2. SR 3.6.1.1.1 leakage rate requirements are in conformance with 10 CFR 50, Appendix J, Option B and supporting documents (Ref. 3, 4 and 5), as modified by approved exemptions.
(continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6-1 a Revision 3
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES (continued)
APPLICABLE The safety design basis for the primary containment is that SAFETY ANALYSES it must withstand the pressures and temperatures of the limiting DBA without exceeding the design leakage rate.
The DBA that postulates the maximum release of radioactive material within primary containment is a LOCA. In the analysis of this accident, it is assumed that primary containment is OPERABLE such that release of fission products to the environment is controlled by the rate of primary containment leakage.
Analytical methods and assumptions involving the primary containment are presented in References 1 and 2. The safety analyses assume a nonmechanistic fission product release following a DBA, which forms the basis for determination of offsite
'based on an assumed leakage rate from the primary containment. OPERABILITY of the primary containment ensures that the leakage rate assumed in the safety analyses is not exceeded.
The maximum allowable leakage rate for the primary containment (La) is 1.0% by weight of the containment air per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at the design basis LOCA maximum peak containment pressure (Pa) of 48.6 psig.
Primary containment satisfies Criterion 3 of the NRC Policy Statement. (Ref. 6)
LCO Primary containment OPERABILITY is maintained by limiting leakage to < 1.0 La, except prior to each startup after performing a required Primary Containment Leakage Rate Testing Program leakage test. At this time, applicable leakage limits must be met.
Compliance with this LCO will ensure a primary containment configuration, including equipment hatches, that is structurally sound and that will limit leakage to those leakage rates assumed in the safety analyses.
Individual leakage rates specified for the primary containment air lock are addressed in LCO 3.6.1.2.
Leakage requirements for MSIVs and Secondary containment bypass are addressed in LCO 3.6.1.3.
(continued)
SUSQUEHANNA-UNIT 1 TS / B 3.6-2 Revision 4
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES (continued)
APPLICABILITY In MODES 1, 2, and 3, a DBA could cause a release of radioactive material to primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations of these MODES.
Therefore, primary containment is not required to be OPERABLE in MODES 4 and 5 to prevent leakage of radioactive material from primary containment.
ACTIONS A. 1 In the event primary containment is inoperable, primary containment must be restored to OPERABLE status within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time provides a period of time to correct the problem commensurate with the importance of maintaining primary containment OPERABILITY during MODES 1, 2, and 3.
This time period also ensures that the probability of an accident (requiring primary containment OPERABILITY) occurring during periods where primary containment is inoperable is minimal.
B.1 and B.2 If primary containment cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
SURVEILLANCE SR 3.6.1.1.1 REQUIREMENTS Maintaining the primary containment OPERABLE requires compliance with the visual examinations and leakage rate test requirements of the Primary Containment Leakage Rate Testing Program. The primary containment concrete visual examinations may be performed during either power operation, e.g., performed concurrently with other primary containment inspection-related activities, or during a maintenance or refueling outage. The visual examinations of the steel liner plate inside primary containment are performed during maintenance or refueling outages since this is the only time the liner plate is fully accessible.
(continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6-3 Revision 3
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES SURVEILLANCE SR 3.6.1.1.1 (continued)
REQUIREMENTS Failure to meet air lock leakage testing (SR 3.6.1.2.1) or resilient seal primary containment purge valve leakage testing (SR 3.6.1.3.6) does not necessarily result in a failure of this SR. The impact of the failure to meet these SRs must be evaluated against the Type A, B, and C acceptance criteria of the Primary Containment Leakage Rate Testing Program. As left leakage prior to each startup after performing a required leakage test is required to be < 0.6 La for combined Type B and C leakage, and _< 0.75 La for overall Type A leakage. At all other times between required leakage rate tests, the acceptance criteria is based on an overall Type A leakage limit of
< 1.0 La. At < 1.0 La the offsite and control room dose consequences are bounded by the assumptions of the safety analysis. The Frequency is required by the Primary Containment Leakage Rate Testing Program.
SR Frequencies are as required by the Primary Containment Leakage Rate Testing Program. These periodic testing requirements verify that the primary containment leakage rate does not exceed the leakage rate assumed in the safety analysis.
As noted in table B 3.6.1.3-1, an exemption to Appendix J is provided that isolation barriers which remain water filled or a water seal remains in the line post-LOCA are tested with water and the leakage is not included in the Type B and C 0.60 L, total.
SR 3.6.1.1.2 Maintaining the pressure suppression function of primary containment requires limiting the leakage from the drywell to the suppression chamber. Thus, if an event were to occur that pressurized the drywell, the steam would be directed through the downcomers into the suppression pool. This SR measures drywell to suppression chamber leakage to ensure that the leakage paths that would bypass the suppression pool are within allowable limits. The allowable limit is 10% of the acceptable SSES A/Ak design valve. For SSES, the A/'/k design value is
.0535 ft2.
Satisfactory performance of this SR can be achieved by establishing a known differential pressure between the drywell and the suppression chamber and determining the leakage. The leakage test is performed when the 10 CFR 50, Appendix J, Type A test is performed in accordance with the Primary Containment Leakage Rate Testing Program. This testing Frequency was developed considering this test is performed in conjunction with the Integrated Leak rate test (continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6-4 Revision 4
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES SURVEILLANCE SR 3.6.1.1.2 (continued)
REQUIREMENTS and also in view of the fact that component failures that might have affected this test are identified by other primary containment SRs. Two consecutive test failures, however, would indicate unexpected primary containment degradation; in this event, as the Note indicates, increasing the Frequency to once every 24 months is required until the situation is remedied as evidenced by passing two consecutive tests.
SR 3.6.1.1.3 Maintaining the pressure suppression function of primary containment requires limiting the leakage from the drywell to the suppression chamber. Thus, if an event were to occur that pressurized the drywell, the steam would be directed through downcomers into the suppression pool. This SR measures suppression chamber-to-drywell vacuum breaker leakage to ensure the leakage paths that would bypass the suppression pool are within allowable limits. The total allowable leakage limit is 30% of the SR 3.6.1.1.2 limit. The allowable leakage per set is 12% of the SIR 3.6.1.1.2 limit.
The leakage is determined by establishing a 4.3 psi differential pressure across the drywell-to-suppression chamber vacuum breakers and verifying the leakage. The leakage test is performed every 24 months. The 24 month Frequency was developed considering the surveillance must be performed during a unit outage. A Note is provided which allows this Surveillance not to be performed when SR 3.6.1.1.2 is performed. This is acceptable because SIR 3.6.1.1.2 ensures the OPERABILITY of the pressure suppression function including the suppression chamber-to-drywell vacuum breakers.
REFERENCES
- 1.
FSAR, Section 6.2.
- 2.
FSAR, Section 15.
- 3.
10 CFR 50, Appendix J, Option B.
- 4.
Nuclear Energy Institute, 94-01 (continued)
SUSQUEHANNA-UNIT I TS / B 3.6-5 Revision 3
PPL Rev. 4 Primary Containment B 3.6.1.1 BASES REFERENCES (continued)
- 5.
- 6.
Final Policy Statement on Technical Specifications Improvements July 22, 1993 (58 FR 39132)
- 7.
Standard Review Plan 6.2.4, Rev. 1, September 1975 SUSQUEHANNA - UNIT 1 TS / B 3.6-6 Revision 3
PPL Rev. 4 Primary Containment B 3.6.1.1 TABLE B 3.6.1.1-1 INSTRUMENT ISOLATION VALVES (Page 1 of 2)
PENETRATION INSTRUMENT ISOLATION NUMBER VALVE X-3B PSH-C72-1 N002A IC-PSH-1 N002A PSH L C72-1N004 IC-PSHL-1N004 PS-Ell-INO10A IC-PS-1 N01OA PS-E1l-iNO11A IC-PS-1NO11A PSH-C72-1N002B IC-PSH-1NO02B PS-E11-1 NO10C IC-PS-i NO10C PS-EI-INO11C IC-PS-1NO11C PSH-15120C IC-PSH-15120C X-32A PSH-C72-1 NO02D IC-PSH-1 N002D PS-El1-iNO10B IC-PS-iN010B PS-El1-lNO11B IC-PS-1 N011 B PSH-C72-1 N002C IC-PSH-1 N002C PS-Eli-lNO10D IC-PS-IN010D PS-Ell-1NO11D IC-PS-1N011D PSH-15120D IC-PSH-15120D X-39A FT-15120A IC-FT-15120A HIGH and IC-FT-15120A LOW X-39B FT-15120B IC-FT-15120B HIGH and IC-FT-15120B LOW X-90A PT-15709A IC-PT-15709A PT-15710A IC-PT-15710A PT-15728A IC-PT-15728A X-90D PT-15709B IC-PT-15709B PT-15710B IC-PT-15710B PT-15728B IC-PT-15728B SUSQUEHANNA - UNIT 1 TS / B 3.6-6a Revision 2
PPL Rev. 4 Primary Containment B 3.6.1.1 TABLE, B 3.6.1.1-1 INSTRUMENT ISOLATION VALVES (Page 2 of 2)
PENETRATION INSTRUMENT ISOLATION NUMBER VALVE X-204A/205A FT-15121A IC-FT-15121A HIGH and IC-FT-15121A LOW X-204B/205B FT-15121B IC-FT-15121B HIGH and IC-FT-15121B LOW X-219A LT-15775A IC-LT-15775A REF and IC-LT-15775A VAR LSH-E41-1N015A 155027 and 155031 LSH-E41-1NO15B 155029 and 155033 X-223A PT-15702 IC-PT-15702 X-232A LT-15776A IC-LT-15776A REF and IC-LT-1 5776A VAR PT-15729A IC1-PT-15729A LI-15776A2 IC-LI-15776A2 REF and IC-LI-1 5776A2 VAR X234A LT-15775B IC-LT-15775B REF and IC-LT-15775B VAR X-235A LT-15776B IC-LT-15776B REF and IC-LT-15776B VAR PT-15729B IC1-PT-15729B SUSQUEHANNA - UNIT 1 TS / B 3.6-6b Revision 3
PPL Rev. 4 Primary Containment B 3.6.1.1 TABLE B 3.6.1.1-2 H20 2 ANALYZER PANEL ISOLATION VALVES PENETRATION NUMBER PANEL ISOLATION VALVE(a)
X-60A, X-88B, X-221A, X-238A 157138 157139 157140 157141 157142 X-80C, X-233, X-238B 157149 157150 157151 157152 157153 (a)
Only those valves listed in this table with current leak rate test results, as identified in the Leakage Rate Test Program, may be used as isolation valves.
SUSQUEHANNA-UNIT 1 TS / B 3.6-6c Revision 0