RA-11-089, Submittal of Relief Requests for the Fifth Inservice Testing (IST) Interval

From kanterella
(Redirected from ML113250626)
Jump to navigation Jump to search

Submittal of Relief Requests for the Fifth Inservice Testing (IST) Interval
ML113250626
Person / Time
Site: Oyster Creek
(DPR-016)
Issue date: 11/17/2011
From: Jesse M
Exelon Corp, Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA-11-089
Download: ML113250626 (14)


Text

10 CFR 50.55a November 17, 2011 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Oyster Creek Nuclear Generating Station Renewed Facility Operating License No. DPR-16 NRC Docket No. 50-219

Subject:

Submittal of Relief Requests for the Fifth Inservice Testing (1ST) Interval In accordance with 10 CFR 50.55a, "Codes and standards," paragraph (a)(3)(i), Exelon Generation Company, LLC (Exelon), is requesting relief from the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants associated with the Oyster Creek Nuclear Generating Station (OCNGS) fifth Inservice Testing (1ST) interval. We request your approval by November 17, 2012.

There are no regulatory commitments in this letter.

If you have any questions conceming this letter, please contact Tom Loomis at (610) 765-5510.

Respectfully, ichael D. Jesse Director - Licensin ulatory Affairs Exelon Generation Company, LLC Attachments: 1) Relief Request PR-01

2) Relief Request VR-01
3) Relief Request VR-02 cc:

Regional Administrator, Region I, USNRC USNRC Senior Resident Inspector, OCNGS Project Manager [OCNGS] USNRC Relief Request PR-Ol

Relief Request PR*Ol Concerning the Proposed Use of Code Case OMN*18 in Accordance with 10 CFR 50.55a(a)(3)(i) lof 1.0 ASl\\1E Code Component(s) Affected P~3~3A,B,C&D, Emergency Service Water Pumps (Vertical Line Shaft / Group AB /

Class 3)

P-5-1&2, Reactor Building Closed Cooling Water Pumps (Centrifugal/Group A / Class 3)

P-ll-I&2, Condensate Transfer Pumps (Centrifugal/Group A / Class 3)

P-18-1 A&B, Spent Fuel Pool Cooling Pumps (Centrifugal/Group A / Class 3)

P-19-1A&B, Liquid Poison Pumps (Positive Displacement / Group AB / Class 2)

P-20-1A,B,C&D, Core Spray Pumps (Centrifugal/Group AB / Class 2)

P-20-2A,B,C&D, Core Spray Booster Pumps (Centrifugal/Group AB / Class 2) l-IA,B,C&D, Containment Spray Pumps (Centrifugal/Group AB / (Class 2)

Component/System Function Various, As Applicable

2.0 Applicable Code Edition and Addenda

The Oyster Creek Nuclear Generating Station (OCNGS) fifth Inservice Testing (1ST) interval will comply with the ASME OM Code-2004 Edition, with Addenda through OMb-2006.

3.0 Applicable Code Reguirement(s) o ISTB-3300, "Reference Values," states, in part, that "Reference values shall be established within +/-20 percent of pump design flow rate for the comprehensive test,"

and "reference values shall be established within +/-20 percent of pump design flow for the Group A and Group B tests, if practicable."

o ISTB-3400, "Frequency of Inservice Tests," states that an inservice test shall be run on each pump as specified in Table ISTB-3400-1.

o Table ISTB-3400-1 requires Group A and Group B tests to be performed quarterly and a comprehensive test to be performed biennially.

o Table ISTB-351O-1, "Required Instrument Accuracy," specifies the instrument accuracies for Group A, Group B, comprehensive, and preservice tests.

o Table ISTB-5121-1, "Centrifugal Pump Test Acceptance Criteria," defines the required acceptance criteria for Group A, Group B, and comprehensive tests for centrifugal pumps.

o Table ISTB-5221 1, "Vertical Line Shaft Centrifugal Pump Test Acceptance Criteria,"

defines the required acceptance criteria for Group A, Group B, and comprehensive tests for Vertical Line Shaft centrifugal pumps.

o Table ISTB-5321-2, "Reciprocating Positive Displacement Pump Test Acceptance Criteria," defines the required acceptance criteria for Group A, Group B, and comprehensive tests for Reciprocating Positive Displacement pumps.

Relief Request PR-Ol Concerning the Proposed Use of Code Case OJ\\:IN-18 in Accordance with 10 CJ; 4R 50.55a(a)(3)(i) 2 of

4.0 Reason for Request

The ASME approved Requirements for Pumps Quarterly within +/-

has not been approved for use in Regulatory Guide 1.1 Code Case Acceptability, ASME OM Code," June 2003.

OMN-18, "Alternative Testing of Design Flow." This Code Case "Operation and Maintenance This Code allows the Owner to not perform the comprehensive test with the associated acceptance criteria, if the quarterly test is performed at +/- 20% of design flow and the instrnmentation meets the accuracy requirements of Table ISTB-3510-1 for the comprehensive and tests.

Further, ISTB allows the Owner to categorize the pumps in their program. As such, an Owner could categorize a pump that otherwise meets the requirements of Group B, as a Group A (or AB) pump, and test according to the provisions of Code Case OMN-18.

However, in doing so they are obtaining additional data (vibration and flow or differential pressure) quarterly, rather than once every two years.

This would allow OCNGS to perform better trending of pump performance data due to the more consistent requirements for each of the quarterly tests. As a result of the increased requirements on the parameters imposed by the proposed alternative during applicable quarterly tests, there is no added value in performing the biennial comprehensive tests on the subject pumps.

5.0 Proposed Alternative and Basis for Use

OCNGS is proposing to utilize the provisions of Code Case OMN-18 and performing a modified Group A test in lieu of performing the Code-required Comprehensive Pump Test (CPT). The modified Group A will be run at +/- 20% of the pump's design flow rate using

+/- '12% accurate gauges to determine the pump differential pressure. Vibration tests will be performed and the vibration acceptance criteria for the proposed alternative test will remain identical to the standard Group A test. Additionally, OCNGS will utilize a Required Action Range High limit of 106% or lower for quarterly testing, which is also consistent with the planned Code change applicable to CPT.

The tightened Required Action Range, in conjunction with using more accurate pressure instruments during testing, provides more consistent trend results when comparing subsequent tests. Due to the improved accuracy, consistent testing methodology, and the addition of quarterly vibration monitoring on Group AB pumps, deviations in actual pump performance indicative of impending degradation are more easily recognized during quarterly performance trending activities. Additionally, declaring pumps inoperable for reasons other than actual equipment degradation can be avoided.

ReHef Request PR-Ol Concerning the Proposed Use of Code Case OJ\\iIN-18 in Accordance with 10 CFR 50.55a(a)(3)(i) 30f the provisions of this relief request as an alternative to the requirements of ISTB-3400 and Tables lSTB-5121-1, ISTB-5221-1, and ISTB-5321-2 provides a reasmlable alternative to the Code requirements based on the determination that the prCtpose<1 alternative provides an acceptable level of quality and safety. Therefore, pursuant to 10 CFR 50.55a(a)(3)(i), OCNGS requests relief from the specific ISTB requirements identified in this request.

6.0 Duration of Proposed Alternative

The proposed alternative identified in this relief request shall be utilized during the fifth 1ST interval which is scheduled to begin October 14,2012 and conclude on October 13, 2022.

7.0 Precedents

A similar Relief Request (PR-9) was approved for the St. Lucie, Units 1 and 2 as discussed in the U.S. Nuclear Regulatory Commission Safety Evaluation Report dated July 1,2011 (MLllI43A077).

A similar Relief Request was approved for the Perry Nuclear Power Plant, Unit 1, as discussed in the U.S. Nuclear Regulatory Commission Safety Evaluation Report dated October 8, 2009 (ML092640690).

Relief Request VR-Ol

ReUd Request VR-01 Concerning ReUef Valve Testing in Accordance with 10 CFR 50.55a(a)(3)(0 10f 1.0 ASME Code Component(s) Affected V~l 160, Main Safety Valve (Class 1)

V~1-161, Main Valve (Class 1)

V~1 162, Main Steam Safety Valve (Class 1)

V~l 163, Main Steam Safety Valve (Class 1)

V-I 164, Main Steam Safety Valve (Class 1)

V-I 165, Main Steam Safety Valve (Class 1)

V-1-166, Main Steam Safety Valve (Class 1)

V-I 167, Main Steam Safety Valve (Class 1)

V-I 168, Main Steam Safety Valve (Class 1)

Component/System Function The Main Steam Safety Valves (MSSVs) provide Reactor Pressure Vessel (RPV) overpressurization protection by opening at their designated set point. Per Technical Specification 4.3.E, four (4) of the valves have a designated set point of 1212 +/-36 psig and the (5) valves have a designated set point of 1221 +/-36 psig.

2.0 AppUcable Code Edition and Addenda The Oyster Creek Nuclear Generating Station (OCNGS) fifth Inservice Testing (1ST) interval will comply with the ASME OM Code-2004 Edition, with Addenda through OMb-2006.

3.0 AppUcable Code Requirement(s)

Appendix 1, Paragraph 1-1320(a), "5-Year Test Interval," specifies that Class 1 pressure relief valves shall be tested at least once every 5 years, starting with initial electric power generation. No maximum limit is specified for the number of valves to be tested within each interval; however, a minimum of 20% of the valves from each valve group shall be tested within any 24-month interval. This 20% shall consist of valves that have not been tested during the current 5-year interval, if they exist. The test interval for any individual valve shall not exceed 5 years.

4.0 Reason for Request

The ASME Code committees developed Code Case OMN-17, "Alternative Rules for Testing ASME Class 1 Pressure Relief/Safety Valves." OMN-17 was recently published in the 2009 Edition of the ASME OM Code. OMN-17 allows owners to extend the test interval for Class 1 safety and relief valves from 60 months to 72 months plus a 6-month grace period.

Relief Request VR-Ol Concerning Relief Valve Testing in Accordance with 10 CFR 50.55a(a)(3)(i) 2 of OCNGS has transitioned from an 18-month fuel to a 24-month fuel cycle. Prior to transitioning to the 24-month fuel cycle, ASME Code requirements could be satisfied by removing and testing one-third of the 9 main steam valves refueling outage in order to comply with the test interval requirements for Class 1 pressure relief valves imposed by the Code of Record during that time. Since transitioning to the 24-month fuel cycle, OCNGS normally removes approximately one-half of the subject relief valves each refueling outage for off-site testing.

The removal of half of the 9 valves versus a third of the valves each outage requires the removal of additional insulation, instrumentation, and other interferences. This additional work results in an undesirable increase in radiation exposure to maintenance personnel.

Extending the test interval to 6 years would reduce the minimum number of MSSVs tested over three refueling outages by up to five valves. The MSSVs are located in the upper elevations of the drywell. Reducing MSSV testing results in lower radiation exposure and a reduction in the cost for valve replacements.

5.0 Proposed Alternative and Basis for Use

As an alternative to the Code required 60 month test interval per Appendix I, Paragraph 1-1320(a), OCNGS proposes that the subject Class 1 pressure relief valves be tested at least once every 72 months plus a six month grace period, if required, in accordance with ASME OM Code Case OMN-17 with a minimum of 20% of the valves tested within any 24-month interval. This 20% would consist of valves that have not been tested during the current six year interval, if they exist. The test interval for any individual valve would not exceed 72 months plus a 6 month grace period to accommodate extended operating cycles.

The ASME Code committees developed Code Case OMN-17, "Alternative Rules for Testing ASME Class 1 Pressure Relief/Safety Valves." OMN-17 was recently published in the 2009 Edition of the ASME OM Code. This Code Case has not been approved for use in Regulatory Guide 1.192, "Operation and Maintenance Code Case Acceptability, ASME OM Code," June 2003. OMN-17 allows owners to extend the test interval for Class 1 safety and relief valves from 60 months to 72 months plus a 6-month grace period. The Code Case imposes a special maintenance requirement to disassemble and inspect each safety and relief valve to verify that patts are free from defects resulting from time related degradation or service induced wear prior to the start of the extended test intervaL The purpose of this maintenance is to reduce the potential for setpoint drift. The approved and qualified procedure that is used by the off-site vendor for disassembly, inspection, repair, and testing of the MSSVs satisfies this special maintenance requirement specified in OMN-17. All currently installed MSSVs were as-found tested, disassembled, inspected, and repaired, followed by post maintenance recertification in accordance with the qualified procedure, prior to installation to verify that parts were free from defects resulting from time related degradation or maintenance induced wear. Therefore, the currently installed MSSVs comply with OMN-17. Furthermore, each MSSV removed from service will

Relief Request VR-Ol Concerning Relief Valve Testing in Accordance with 10 CJ;"'R 50.55a(a)(3)(0 3 of continue to be disassembled, inspected, repaired, and tested in accordance with the qualified procedure and the requirements of OMN-17 prior to reinstallation.

OCNGS has a of 19 MSSVs of which nine are installed in the plant. The valve and maintenance cycle at OCNGS consists of removal of the MSSV complement requiring and transport to an off-site test facility. Upon receipt at the off-site facility the valves are subject to as-found inspection and set pressure testing. Prior to return of a complement of MSSVs for installation in the plant, the valves are disassembled and inspected to verify that internal surfaces and parts are free from defects or service induced wear prior to the start of the next test interval. During this process, anomalies or damage are identified and dispositioned for resolution. Damaged or worn parts, springs, gaskets and seals are replaced as necessary. The valves are lubricated and the valve seats are relapped. Each valve is then recertified for service. Although the ASME Code does not require maintenance to be routinely performed on relief valves, maintenance prior to installation provides reasonable assurance that set pressure drift will be minimized.

OCNGS has reviewed the as-found set point testing results for all MSSVs tested since 1999 as the following summary of test OCNGS found that the average as-found set pressure is 1211.7 psig. OCNGS identified two (2) tests that exceeded the Technical Specifications as-found +/-3% acceptance criteria.

1.

MSSV BW05087 was as-found tested on 10/23/2000. The as-found set pressure of 1262 psig deviated from the set pressure of 1212 psig by 4.1%. Upon disassembly and inspection, the spindle was found out of round at the lower washer contact point by 0.034". The bent spindle was replaced. No other deficiencies were noted. Minor lapping was done to restore seat integrity. All other parts were cleaned, inspected, buffed and lubricated as required.

2.

MSSV BY08715 was as-found tested on 8/1012004. The as-found set pressure of 1268 psig deviated from the set pressure of 1221 psig by 3.8%. Upon disassembly and inspection contact between the spring and the spring can was noted. The can casting high spots were removed eliminating the contact points. The seats required minimal lapping. Wear areas were cleaned and wear areas and contact points were lubricated prior to assembly. The increase in as-found set pressure is attributed to the higher side loading caused by the spring contacting the side of the can.

Relief Request VR*Ol Concerning Relief Valve Testing in Accordance with 10 C};~R 50.55a(a)(3)(i) 4 of

SUMMARY

OF TEST RESULTS OYSTER CREEK MAIN STEAM SAFETY VALVES (CONSOLIDATED/DRESSER MODEL 3777QA)

SET AS-FOUND AS FOUND VALVE ID PRESSURE TEST DATE SET RESULT PRESSURE BWOS084 1212 6/2/1999 1218 O.S%

BWOS08S 1221 612/1999 1192

-2.4%

BWOS086 1221 6/1/1999 1228 0.6%

BWOS089 1212 612/1999 1203

-0.7%

BWOS090 1212 6/1/1999 1204

-0.7%

BY08710 1212 612/1999 1194 I.S%

BY08712 1221 6/3/1999 1204

-1.4%

BY08713 1221 6/1/1999 1220

-0.1%

BY08714 1221 6/1/1999 1231 0.8%

BWOS087 1212 1012312000 1262 4.1%(1)

BWOS088 1212 1012412000 119S

-1.4%

BWOS091 1221 1012312000 1210

-0.9%

BWOS092 1221 1012312000 1206

-1.2%

BY08708 1212 111212000 1210

-0.2%

BY08711 1212 11/212000 1193

-1.6%

BY0871S 1221 1112/2000 1239 I.S%

BY08716 1221 11/3/2000 1211

-0.8%

BY08717 1221 10123/2000 1201

-1.6%

BWOS084 1212 10/1312002 1241 2.4%

BY08710 1212 10/1412002 1226 1.2%

BWOS092 1221 8/9/2004 121S

-O.S%

BW08709 1212 8/13/2004 1220 0.7%

BY0871S 1221 8/1012004 1268 3.8% (2)

BY08714 1221 1O/31200S 1198 1.9%

BWOS089 1212 10/41200S 1223 0.9%

BWOS087 1212 10/4/200S 1182

-2.S%

BY08712 1221 10/S1200S 1212

-0.7%

BWOS090 1212 10/S1200S 1206

-O.S%

BWOS086 1221 1O/6/200S 1212

-0.7%

BY08711 1212 1O/61200S 1213 0.1%

BY08713 1221 1O/131200S 1204

-1.4%

BY08709 1212 61212006 1212 0.0%

BWOS088 1212 1012712006 1183

-2.4%

BWOS091 1221 10127/2006 1196

-2.0%

Relief Request VR..01 Concerniug Relief Valve Testing in Accordan.ce with 10 CE~R VALVEID AS FOUND RESULT The OCNGS data indicates a tendency toward lower as-found set points, but this tendency is well within the OCNGS Technical Specification required limits, which require set point deviations to be within prclpo:sed altt~m:lti\\Te to test for the subject Class 1 pressure relief valves from 60 months to 72 months plus a 6-month grace period will continue to provide an acceptable level of quality and safety while restoring the operational and maintenance flexibility that was lost when the 24-month fuel cycle created the unintended consequences of more This proposed alternative will continue to provide assurance of the valves' and provides an acceptable level of quality and safety pursuant to 10 CFR 50.55a(a)(3)(i).

6.0 Duration of Proposed Alternative

The proposed alternative identified in this relief request shall be utilized during the fifth 1ST interval which is scheduled to begin October 14, 2012 and conclude on October 13, 2022.

7.0 Precedents

A similar Relief Request was approved for the Clinton Power Station, Unit No.1, as discussed in the U.S. Nuclear Regulatory Commission Safety Evaluation Report dated June 10,2010 (MLI01340691).

A similar Relief Request (VRR-06) was approved for the James A. Fitzpatrick Nuclear Power Plant as discussed in the U.S. Nuclear Regulatory Commission Safety Evaluation Report dated October 1,2009 (ML092730032).

Relief Request VR-02

V-27-4 V-28-17 V-28-18 V-28-47 V-5-147 V-5-166 V-5-167 Relief Request VR-02 Concerning Remote Position Indication for Containment Isolation Valves in Accordance with 10 CFR 50.55a(a)(3)(i) lof 1.0 ASl\\tfE Code Component(s) Affected The following containment isolation valves in various svs:terns:

V-23-13 14 V-23-15 V-23-16 V-23-18 V-23-20 V-23-21 V-27-1 V-27-2 Component/System Function The valves must be capable of closing to provide containment isolation during post-accident conditions.

2.0 Applicable Code Edition and Addenda

The Oyster Creek Nuclear Generating Station (OCNGS) fifth Inservice Testing (1ST) interval will comply with the ASME OM Code-2004 Edition, with Addenda through OMb-2006 3.0 Applicahle Code Requirement(s)

OM Code ISTC-3700 Valves with remote position indicators shall be observed locally at least once every two years to verify that valve operation is accurately indicated.

4.0 Reason for Request

The above valves are located in high radiation areas. Local observation to verify the accuracy of the position indicators will result in unnecessary radiation exposure to plant personnel. Without Code relief, the incremental outage work due to the inclusion of the 17 additional verifications of remote position indication would be contrary to the principle of maintaining exposure to radiation as low as reasonably achievable. Alternate means can be used to verify accurate valve position indication. As discussed in Section 4.2.7 of NUREG-1482, Rev.l, methods other than local observation, such as nonintrusive techniques, causing the flow to begin or cease, leak testing, and pressure testing can yield a positive indication of valve position. Observation of operational parameters such as leakage, pressure, and flow should be considered an acceptable approach since it is consistent with the intent of ISTC-3700.

Relief Request VR-02 Concerning Remote Position Indication for Containment Isolation Valves in Accordance with 10 CFR 50.55a(a)(3)(i) 2 of

5.0 Proposed Alternative and Basis for Use

The position indicators for the above valves will be verified at least once every 2 years. In lieu of local observation, the following method will be used to verify accurate position indication. Proper system operation will verify accurate open position indication, and successful leak rate test results each refueling outage will verify accurate closed indication.

containment isolation valves are not on an extended 10 CFR 50, Appendix J, Option B test frequency.

provisions of this relief request as an alternative to local observation of valve position per ISTC-3700 is consistent with Section 4.2.7 of NUREG-1482, Rev. 1 and provides an acceptable level of quality and safety without needlessly exposing plant personnel to high levels of radiation. Furthermore, using measurable system parameters to confirm valve position often provides better assurance of stem-disc integrity.

Similar relief requests have been previously submitted and approved for use in both the third and fourth 1ST intervals.

6.0 Duration of Proposed Alternative

The proposed alternative identified in this relief request shall be utilized during the fifth 1ST interval which is scheduled to begin October 14,2012 and conclude on October 13,2022.

7.0 Precedents

A similar relief request (Valve Relief Request No. 51) was approved for the Oyster Creek Nuclear Generating Station as discussed in the U.S. Nuclear Regulatory Commission Safety Evalution Report dated September 24, 1992.

A similar Relief Request (RV-51) was approved for the Oyster Creek Nuclear Generating Station, as discussed in the U.S. Nuclear Regulatory Commission Safety Evaluation Report dated October 2, 2002 (ML022750556).

8.0 References NUREG-1482, Revision 1, Section 4.2.7, "Verification of Remote Position Indication for Valves by Methods Other Than Direct Observation."