Application for Amend to License DPR-49,App a Consisting of Tech Spec Change RTS-148,revising Group I Containment Isolation Signal from Reactor Vessel low-low to low-low-low Water Level.Proprietary Rept Withheld (Ref 10CFR2.790)
ML112230844
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 03/10/1983
From: Root L
IES Utilities, (Formerly Iowa Electric Light & Power Co)
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML112230845 List:
References
NG-83-0717, NG-83-717, NUDOCS 8303170453
Download: ML112230844 (3)


Text

REGULA Y INFORMATION DISTRIBUTIOA YSTEM (RIDS)

ACCESSION NBR:830317045 DCDATE: 83/03/10 NOTARIZED: YES DOCKET #

FACIL;50-331 Duane Arnold Energy Center, Iowa Electric Light & Pow 05000331 AUTH,NAME AUTHOR AFFILIATION ROOTL.D. Iowa Electric Light & Power Coq RECIPNAME RECIPILNT AFFILIATION DENTON,H, Office of Nuclear Reactor Regulation, Director

SUBJECT:

Application for amend to License DPR"49,App A consisting of Tech Spec Change RTS-148,revising Group I containment isolation signal from reactor vessel low-low to low-low-low witer level,Propriet ry "Low,,,," withheld (ref 10cfr2,790),

DISTRIBUTIO CODE PAQ 0 REC 1IVE LTpiCEL X SIZE;.j2 U3L TITLE: Proprietary Review 0U ribution-Operating Reactor NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL NRR URB2 BC 05 .7 7 INTERN AL: ELD/HDS2 1 0 RjJEG FILE~ 1 1 RGN3 7 1

.EXTERNAL: ACRS t,6 LPr 1 0 NRC PDR 1 0 NTIS 1 0 TOTAL NUMBER OF COPIES REUUIRED: LTTR 19 ENCL 15

Iowa Electric Light and Power Company March 10, 1983 NG-83-0717 LARRY D. ROOT ASSISTANT %ICE PRESIDENT NUCLEAR GENERATION Mr. Harold Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Duane Arnold Energy Center Technical Specifications, Appendix A Containment Load Case Avoidance (RTS-148)

Dear Mr. Denton:

Transmitted herewith, in accordance with the requirements of 10 CFR 50.59 and 10 CFR 50.90, is an application for amendment to Appendix A (Technical Specifications) to Operating License DPR-49 for the Duane Arnold Energy Center.

This application, consisting .of proposed Technical Specification change RTS-148, has been reviewed and approved by the DAEC Operations is Committee and the DAEC Safety Committee. The enclosed license amendment Order for required in order to comply with the Nuclear Regulatory Commission Modification of License and Grant of Extension of Exemption (dated January 13, 1981) and Modification of January 13, 1981 Order (dated January 19, 1982). CFR This application, therefore, is considered exempt from fee pursuant to 10 170.22, Footnote 2.

A The purpose of this application is to amend the DAEC Appendix signal from Technical Specifications to revise a Group I Containment Isolation low-low-low water level.

reactor vessel low-low water level to reactor vesel being revised In addition, the Group 1 isolation reactor pressure setpoint is technical from 880 psig to 850 psig. These two modifications, which require specification revisions, are being implemented third in order to provide additional margin for certain containment load cases. A modification, which is being installed during the current refueling outage pursuant to 10 CFR 50.59, at DAEC. This third provides low-low set logic to the two non-ADS S/R valves modification does not require technical specification revision.

"Low Low Set A General Electric Company, proprietary report entitled Arnold for the Duane Relief Logic System and Lower MSIV Water Level Trip enclosed in support of this Energy Center (NEDE-30021), January 1983" is which the General Electric application. The report contains information withholds from public Company customarily maintains in confidence and 8303170453 830310 PDR ADOCK 05000331 1399841

- PDR5 :-!BOX 351

  • Cedar Rapids;, lofwa 52406
  • 319/398-4411

Mr. Harold Denton March 10, 1983 NG-83-0717 Page Two disclosure. The information has been handled and classified as proprietary to General Electric. As indicated in the attached affidavit, we hereby request that NEDE-30021 be withheld from public disclosure in accordance with the provisions of 10 CFR 2.790.

The Commission Orders identified above require major containment modifications to be completed prior to the start of DAEC Cycle 7 and remaining minor containment modifications prior to July 1, 1983. Startup from Cycle 7 is currently scheduled for mid April, 1983. In the generic Mark 1 submittal (MI-G-41, June 14, 1981) MSIV level change was classified as a major modification but was annotated with the comment "Applicability in Question."

Subsequent analysis, as discussed in the attached NEDE-30021, has demonstrated that installation of the low-low set logic is adequate without MSIV level change to mitigate the load cases of concern. As low-low set logic is being installed this outage, a basis is, therefore, provided to reclassify the MSIV level change as a minor modification. However, we request that the NRC approve this application during this outage to avoid the need for reclassification of MSIV level to minor.

Three signed and 37 additional copies of this application are transmitted; five of these copies have the proprietary GE report NEDE-30021 attached. These five copies are stamped in the upper right hand corner as "Company Proprietary." This application, consisting of the foregoing letter and enclosures, is true and accurate to the best of my knowledge and belief.

IOWA E CTRIC LIGHT AND POWER COMPANY BY arry D. Root Subscribed and sworn to Before Me on this / day of AA 1983.

No y ublic in and for the State of Iowa LDR/WJM/dmh*

Attachments cc: W. Miller D. Arnold L. Liu S. Tuthill F. Apicella (NRC)

NRC Resident Office