UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 26, 2011 Mr. Tom Kirwin Vice President, Operations (Acting)

Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530

SUBJECT:

PALISADES NUCLEAR PLANT - CHANGE TO EMERGENCY ACTION LEVEL SCHEME (TAC NO. IVIE3977)

Dear Mr. Kirwin:

By application dated May 6,2010, and supplemented by letter dated March 9, 2011, Entergy Nuclear Operations, Inc., (the licensee), requested prior U.S. Nuclear Regulatory Commission (NRC) approval for proposed changes to the emergency action level (EAL) scheme for the Palisades Nuclear Plant (PNP). The requested changes support a conversion from their current EAL scheme to a scheme based on the Nuclear Energy Institute (NEI) 99-01, "Methodology for Development of Emergency Action Levels," Revision 5, dated February 2008. PNP currently utilizes an EAL scheme that is site-specific yet developed in accordance with the guidance provided in NEI 99-01, Revision 4, dated January 2003.

The NRC staff has completed its review. The NRC staff finds the proposed PNP EAL Scheme to be consistent with the guidance in NEI 99-01, Revision 5, and is an acceptable alternative for development of an EAL scheme that meets the standards in Title 10 of the Code of Federal Regulations (10 CFR) Section 50.47(b) and the requirements in 10 CFR Part 50, Appendix E, Section IV-B.

Therefore, the NRC staff approves the proposed change to the EAL scheme. A copy of the related Safety Evaluation is enclosed.

Sincerely, Eric. eeds, Director Office of Nuclear Reactor Regulation Docket No. 50-255

Enclosure:

Safety Evaluation cc w/encl: Distribution via Listserv

UNrrED STA"rES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555"0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION UPGRADE TO EMERGENCY ACTION LEVEL SCHEME ENTERGY NUCLEAR OPERATIONS, INC.

PALISADES NUCLEAR PLANT DOCKET NO. 50-255

1.0 INTRODUCTION

By application dated May 6,2010, and supplemented by letter dated March 9,2011 (References 12 and 13 respectively), Entergy Nuclear Operations, Inc., (the licensee),

requested prior U.S. Nuclear Regulatory Commission (NRC) approval for proposed changes to the emergency action level (EAL) scheme for the Palisades Nuclear Plant (PNP).

The requested changes support a conversion from their current EAL scheme to a scheme based on the Nuclear Energy Institute (NEI) 99-01, "Methodology for Development of Emergency Action Levels," Revision 5, dated February 2008 (Reference 5). PNP currently utilizes an EAL scheme that is site-specific yet developed in accordance with the guidance provided in NEI 99-01, Revision 4, dated January 2003 (Reference 4).

2.0 REGULATORY EVALUATION

The NRC staff reviewed the proposed revision against the following regulations and guidance described below.

2.1 Regulations Title 10 of the Code of Federal Regulations (10 CFR), Section 50.47, "Emergency plans," sets forth emergency plan requirements for nuclear power plant facilities. The regulations in 10 CFR 50.47(a)(1)(i) state, in part, that

... no initial operating license for a nuclear power reactor will be issued unless a finding is made by the NRC that there is reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency.

Section 50.47{b) establishes the standards that the onsite and offsite emergency response plans must meet for NRC staff to make a positive finding that there is reasonable assurance that the licensee can and will take adequate protective measures in the event of a radiological emergency. Planning Standard (4) of this section requires that a licensee's emergency response plan contain: "A standard emergency classification and action level scheme, the Enclosure

- 2 bases of which include facility system and effluent parameters, is in use by the nuclear facility licensee, and State and local response plans call for reliance on information provided by facility licensees for determinations of minimum initial offsite response measures."

Section IV.S of Appendix E, "Emergency Planning and Preparedness for Production and Utilization Facilities," to 1 0 CFR Part 50, states:

The means to be used for determining the magnitude of, and for continually assessing the impact of, the release of radioactive materials shall be described, including emergency action levels that are to be used as criteria for determining the need for notification and participation of local and State agencies, the Commission, and other Federal agencies, and the emergency action levels that are to be used for determining when and what type of protective measures should be considered within and outside the site boundary to protect health and safety. The emergency action levels shall be based on in-plant conditions and instrumentation in addition to onsite and offsite monitoring. These initial emergency action levels shall be discussed and agreed on by the applicant or licensee and state and local governmental authorities, and approved by the NRC.

Thereafter, emergency action levels shall be reviewed with the State and local governmental authorities on an annual basis. A revision to an emergency action level must be approved by the NRC before implementation if:

(1) The licensee is changing from one emergency action level scheme to another emergency action level scheme (e.g., a change from an emergency action level scheme based on NUREG-0654 to a scheme based upon NUMARC/NESP-007 or NEI 99-01);

(2) The licensee is proposing an alternate method for complying with the regulations; or (3) The emergency action level revision decreases the effectiveness of the emergency plan.

Section 50.47(b)(4) to 10 CFR specifies a standard emergency classification and action level scheme, and as such, the NRC staff will ensure that implementation methods are relatively consistent throughout the industry for a given reactor and containment design while simultaneously providing an opportunity for a licensee to modify their EAL scheme as necessary to address site-specific design considerations or preferences.

The proposed changes were submitted to the NRC for a technical and regulatory review prior to implementation by the licensee, as required under Section IV. S of Appendix E to 10 CFR Part 50. This review is based upon a revision to the PNP EAL scheme provided in the licensee's application letter and supplemented by the licensee's responses to the NRC's request for additional information. Attachment 3 of the licensee's letter dated March 9, 2011 (Reference 13), contains the final version of the licensee's proposed site-specific EAL scheme for Pt\\lP and is therefore the final version reviewed by the NRC for acceptability.

- 3 2.2 Guidance EAL development guidance was initially established via Generic Letter (GL) 79-50 (Reference 1) and subsequently established in NUREG-0654/FEMA-REP-1 (Reference 2),

which was endorsed as an approach for the development of an EAL scheme via NRC Regulatory Guide (RG) 1.101, Revision 2. As industry and regulatory experience was gained with the implementation and use of the EAL scheme, the industry developed revised EAL scheme development guidance documents to gain the benefit of lessons learned. To date, NUMARC/NESP-007 (Reference 3), NEI 99-01, Revision 4 (Reference 4), and NEI 99-01, Revision 5, were provided to the NRC for review and endorsement as generic (non site-specific)

EAL development guidance. RG 1.101, Revisions 3 and 4 (Reference 6) endorsed NUMARC/NESP-007 and NEI 99-01, Revision 4 as acceptable alternatives for licensees to consider in the development of their site-specific EAL schemes, as well as allowing licensees to develop site-specific EALs based upon an alternative approach not endorsed by the NRC.

NEI 99-01, Revision 5 was endorsed as generic (non site-specific) EAL development guidance via letter dated February 22, 2008 (Reference 7), and will be further endorsed in the next revision of RG 1.101.

GL 79-50, NUREG-0654/FEMA-REP-1, NUMARC/NESP-007, NEI 99-01, Revision 4, and NEI 99-01, Revision 5 are all considered generic EAL development guidance documents, as they are not site-specific and may not be entirely applicable for some reactor designs.

However, the guidance contained in these documents bounds the most typical accident/event scenarios for which emergency response is necessary in a format that allows for industry standardization and consistent regulatory oversight. Most licensees choose to develop their site-specific EAL schemes using the latest endorsed EAL development guidance with appropriate site-specific alterations, as applicable. A change in an EAL scheme to incorporate the improvements provided in NUMARC/NESP-007 or NEI 99-01 would not decrease the overall effectiveness of the emergency plan; however, due to the potential safety significance of the change, the change needs prior NRC review and approval.

The NRC considers the following methods acceptable for use in developing site-specific EALs that meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), with the understanding that licensees may want to develop EALs that differ from the applicable guidance document as allowed in RG 1.101 and in the letter dated February 22, 2008:

  • Appendix 1, "Emergency Action Level Guidelines for Nuclear Power Plants," to NUREG 0654/FEMA-REP-1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," dated November 1980; NUMARC/NESP-007, Revision 2, "Methodology for Development of Emergency Action Levels," dated January 1992;
  • NEI 99-01, Revision 4, "Methodology for Development of Emergency Action Levels,"

dated January 2003; and

-4 NEI 99-01, Revision 5, "Methodology for Development of Emergency Action Levels,"

dated February 2008.

NRC Regulatory Issue Summary (RIS) 2003-18, with Supplements 1 and 2, "Use of NEI 99-01, Methodology for Development of Emergency Action Levels" (Reference 9), also provide guidance for developing or changing a standard emergency classification and action level scheme. In addition, this RIS and its Supplements provide recommendations to assist licensees, consistent with Section IV.B of Appendix E to Part 50, in determining whether to seek prior NRC approval of deviations from the guidance.

Regardless of the generic EAL scheme development guidance document used by a licensee to develop their EAL scheme, or if a licensee chose to develop their EAL scheme using an alternative approach not endorsed by the NRC, or a combination of the two (most typical), the NRC will review the EAL scheme to ensure it meets the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4).

3.0 TECHNICAL EVALUATION

In its application and supplemental letter, the licensee submitted the proposed EAL scheme for PI\\IP, their technical basis, a comparison matrix, the EAL numbering scheme, and an explanation for any difference or deviation from NEI 99-01. The comparison matrix provided a cross reference relating the proposed EAL scheme to the EAL scheme in NEI 99-01, Revision 5.

PNP currently utilizes an EAL scheme based on the generic EAL scheme development guidance from NEI 99-01, Revision 4, with site-specific modifications due to design issues and/or licensee preference. The licensee is converting to an EAL scheme using the development guidance from NEI 99-01, Revision 5, with site-specific modifications due to design issues and/or licensee preference.

The proposed site-specific EAL scheme is unique to PNP; however, to ensure consistency and regulatory stability, the NRC staff reviewed the proposed site-specific EAL scheme to ensure the following key characteristics of an effective EAL scheme are in place:

  • Consistency (Le., the EALs would lead to similar decisions under similar circumstances at different plants), up to and including standardization in intent, if not in actual wording; Human engineering and user friendliness; Potential for classification upgrade only when there is an increasing threat to public health and safety; Ease of upgrading and downgrading;
  • Thoroughness in addressing and disposing of the issues of completeness and accuracy raised regarding Appendix 1 to NUREG-0654; Technical completeness for each classification level;

- 5 Logical progression in classification for multiple events; and Objective and observable values.

To aid in understanding the nomenclature used in this Safety Evaluation (SE), for each category of EALs reviewed the following naming/numbering convention is used: the first letter signifies the category; the second letter signifies the classification level {G = General Emergency (GE),

S = Site Area Emergency (SAE), A = Alert, U = Notification of Unusual Event (UE>>; and the number is the applicable number from the site-specific EAL scheme. For ease of use, this SE will use the numbering system from the site-specific EAL scheme rather than from the generic EAL development guidance.

3.1 CATEGORY 'A' - ABNORMAL RADIOLOGICAL RELEASE/RADIOLOGICAL EFFLUENT 3.1.1 EAL Set AG1/AS1/AA1/AU1 This EAL set is based upon site-specific indications of a release of radioactivity (gaseous and/or liquid). The progression from UE to GE is appropriate and consistent with EAL scheme development guidance.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47{b){4), and therefore, is acceptable for implementation.

3.1.2 EAL Set AA2/AU2 This EAL set is based upon site-specific indications of fuel uncovery. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident progression are bounded by indications available in the fission barrier matrix as well as EALs AS1 and AG1.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and

- 6 format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set pOints derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.1.3 EAL AA3 This EAL set is based upon indications of a rise in plant radiation levels that impedes normal access to the Control Room (CR) and Central Alarm Station (CAS).

The Alert EAL is primarily intended to ensure the site emergency response organization is activated to support the CR in removing the impediment to normal access to the CR and CAS.

Indications of increasing radiation levels in the plant are bounded by indication of fission barrier loss or potential loss, as well as AS1 and AG1.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.2 CATEGORY 'C' - COLD SHUTDOWN/REFUELING SYSTEM MALFUNCTION 3.2.1 EAL Set CA 1/CU1 This EAL set is based upon a loss of available alternating current (AC) power sources to the emergency busses. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident progression are bounded by indications available in EALs AS1 and AG1.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and

- 7 format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided. and is considered part of a standard EAL scheme.

The instrumentation. values. and listing of applicable power sources derived for this EAL set are consistent with the overall EAL scheme development guidance. address the site-specific implementation strategies provided. and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme. and while different than that provided in the generic EAL development guidance. it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore. is acceptable for implementation.

3.2.2 EAL Set CG3/CS3/CA3/CU3 This EAL set is based upon a loss of reactor pressure vessel inventory. The progression from UE to GE is appropriate and consistent with EAL scheme development guidance. Combining the two UE EALs from the generic guidance into this particular EAL set is acceptable. as the EALs were developed in accordance with the guidance and continue to ensure that an UE classification will be considered for these particular events.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.2.3 EAL Set CA4/CU4 This EAL set is based upon an inability to maintain control of decay heat removal. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident progression are bounded by indications available in EALs AS 1 and AG 1.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition. the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and

- 8 format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.2.4 EAL CU5 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to highlight the importance of emergency communications by ensuring an EAL is declared if normal communication methods for onsite and offsite personnel, or for offsite response organizations including the NRC, are lost.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL are consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The communication methods derived for this EAL are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.2.5 EAL CU6 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to highlight the significance of inadvertent criticality events by ensuring an EAL is declared if unplanned positive and sustained period is observed on nuclear instrumentation.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL are consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic

- 9 EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b){4), and therefore, is acceptable for implementation.

3.2.6 EAL CU2 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to ensure an EAL is declared when a loss of direct current (DC) power event occurs as it compromises the ability of the licensee to monitor and control the removal of decay heat during Cold Shutdown or Refueling modes of operation.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL are consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.3 CATEGORY 'E' -INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI) 3.3.1 EAL EU1 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is limited to radiological events at the ISFSI. While security-related events at the ISFSI are also of concern, they are bounded by the licensee's EAL HA4.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL are consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.4 CATEGORY 'H' - HAZARDS 3.4.1 EAL Set HA1/HU1 This EAL set is based upon the effect that natural and destructive hazards may have on the licensee. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident progression are bounded by indications available in the fission barrier matrix and EALs AS1 and AG1.

- 10 The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The method of determining seismic events is consistent with the development strategies stated in the generic EAL development guidance. Seismic event classification criteria for both the UE and Alert classification levels are appropriate, considered part of a standard EAL scheme, and meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4),

and therefore, are acceptable for implementation.

High wind and tornado events, as well as the development of site-specific areas considered in these EALs, are consistent with the development strategies stated in the generic EAL development guidance. These EALs are considered part of a standard EAL scheme and meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4).

Therefore, these EALs are acceptable for implementation.

Main turbine rotating component failures are appropriately developed using the generic EAL development guidance with site-specific terminology and site-specific areas of consideration determined for these EALs. These EALs are considered part of a standard EAL scheme and meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50,47(b)(4).

Therefore, these EALs are acceptable for implementation.

Internal flooding events are appropriately developed using the generic EAL development guidance with site-specific terminology and site-specific areas of consideration determined for these EALs. While consistent with the development strategies stated in the generic EAL development guidance, the actual wording used is different. However, these EALs are considered part of a standard EAL scheme and meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4). Therefore, these EALs are acceptable for implementation.

The licensee developed additional EALs related to ultimate heat sink water level (high and low) for the UE and Alert classification levels. The instrumentation and set points developed for these EALs are appropriate and applicable for this licensee. The generic EAL scheme development guidance, as well as NUREG-0654/FEMA-REP-1, has the licensee consider unique hazard events applicable to their specific site and to develop site-specific EALs to address these hazards. These EALs are considered part of a standard EAL scheme and meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4).

Therefore, these EALs are acceptable for implementation.

Events based upon vehicle crashes within the protected area or vital area have typically been difficult to differentiate between the UE and Alert classification levels. GL 79-50, NUREG

- 11 0654/FEMA-REP-1, and NUMARC/NESP-007 used language equating vehicles to aircraft, trains, and barges. NEI 99-01 Revision 4 used language equating vehicles to that large enough to cause damage. With the issuance of NRC Bulletin 2005-02 (Reference 10), the need for EALs related to airborne, waterborne, or land-based security events have been resolved with the development of security-specific EALs. In addition, the intended basis for a UE EAL is, among other considerations, the resultant degradation in the level of safety of the plant.

Eliminating the UE EAL due to vehicle crashes is consistent with the intent of the UE classification and removes any misunderstanding with the remaining Alert classification. The Alert classification is based upon indications of degraded performance or visible damage to a specific list of areas considered applicable to this EAL. Removing the UE EAL based upon vehicle crashes, and revising the wording of the remaining Alert EAL, continues to be considered part of a standard EAL scheme and meets the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4). Therefore, these EALs are acceptable for implementation.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.4.2 EAL Set HA2/HU2 This EAL set is based upon the effect that fire and explosions may have on the licensee. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident progression are bounded by indications available in the fission barrier matrix, EALs RS1 and RG1, or applicable EALs from the Systems Malfunction category.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generiC EAL scheme development guidance. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The development of site-specific areas considered in these EALs is consistent with the development strategies stated in the generic EAL development guidance even though the actual wording used is different, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.4.3 EAL Set HA3/HU3 This EAL set is based upon the effect that toxic, corrosive, asphyxiant or flammable gases may have on the licensee. The progression from UE to Alert is appropriate and consistent with EAL scheme development guidance. The SAE and GE classification levels for this specific accident

- 12 progression are bounded by indications available in the fission barrier matrix, EALs AS1 and AG1, or applicable EALs from the Systems Malfunction category.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The development of site-specific areas considered in these EALs is consistent with the development strategies stated in the generic EAL development guidance even though the actual wording used is different, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.4.4 EAL Set HG4/HS4/HA4/HU4 The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

This EAL set is based upon security-related events originally developed via the guidance from NRC Bulletin 2005-02 or RIS 2006-12 (Reference 11) for licensees to implement regardless of the specific version of the generic EAL scheme development guidance used, or if the particular licensee developed their EAL scheme using an alternative approach. Based upon lessons learned from implementation and use of this EAL set, particularly from when licensees performed combined security and emergency preparedness drills, the NRC staff and the industry worked to enhance the language of these EALs so as to eliminate any confusion without changing the intent of the EAL set as set forth in NRC Bulletin 2005-02 and RIS 2006-12. The NRC staff generated EAL Frequently Asked Question (EALFAQ) 2009-48 (Reference 8) to address the changes made to the generic EAL scheme development guidance document.

The development of this EAL set is consistent with the guidance provided in NRC Bulletin 2005-02 and RIS 2006-12, as further enhanced by the lessons learned from implementation and drills, and revised in NEI 99-01 Revision 5 and evaluated in EALFAQ 2009-48.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

- 13 3.4.S EAL Set HSS/HAS This EAL set is based upon CR evacuation. The progression from Alert to SAE is appropriate and consistent with EAL scheme development guidance. The GE classification level for this specific accident progression is bounded by indications available in the fission barrier matrix or EALAG1.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part SO and 10 CFR S0.47(b)(4), and therefore, is acceptable for implementation.

3.4.6 EAL Set HG6/HS6/HA6/HU6 This EAL set is based upon providing the EAL decision-maker EALs to consider when their judgment deems an emergency classification is warranted.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance, is consistent with the site specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part SO and 10 CFR S0.47(b)(4), and therefore, is acceptable for implementation.

3.S CATEGORY'S' - SYSTEM MALFUNCTION 3.S.1 EAL Set SG1/SS1/SA1/SU1 This EAL set is based upon a loss of available AC power sources to the emergency busses.

The progression from UE to GE is appropriate and consistent with EAL scheme development guidance.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and

- 14 with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation, values, and listing of applicable power sources derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.2 EAL Set SG3/SS3/SA3/SU3 This EAL set is based upon the effect a failure of the reactor protection system may have on the plant, as well as inadvertent criticality for SU3. The progression from Alert to GE is appropriate and consistent with EAL scheme development guidance, and the inclusion of the UE (SU3) is acceptable as it relates to the EAL set.

The licensee chose to modify this EAL set by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL set is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.3 EAL SU4 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to ensure an EAL is declared when the plant is not brought to the required operating mode within the Technical Specifications Limiting Condition for Operation action statement completion time.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering and format of this EAL is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

- 15 The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.4 EAL Set SS5/SA5/SU5 This EAL set is based upon the effect a loss of indication, control, and annunciation capabilities has on the plant. The progression from UE to SAE is appropriate and consistent with EAL scheme development guidance. The GE classification level for this specific accident progression is bounded by indications available in the fission barrier matrix or EAL AG1.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format other than that provided in the generic EAL scheme development guidance. In addition, the licensee chose to use mathematical symbols instead of their noun equivalent where applicable. The numbering, sequencing, and format of this EAL set is consistent with the overall EAL scheme development guidance and with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The instrumentation and set points derived for this EAL set are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.5 EAL SU6 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to highlight the importance of emergency communications by ensuring an EAL is declared if normal communication methods for onsite and offsite personnel, or for offsite response organizations including the NRC, are lost. No escalation path is necessary for this event progression.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL is consistent with the overall EAL scheme development guidance, is consistent with the site specific implementation strategies provided, and is considered part of a standard EAL scheme.

The communication methods derived for this EAL are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic

- 16 EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.6 EAL SU7 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to ensure an EAL is declared when the plant has indications of fuel clad degradation. By design, this EAL is redundant with corresponding indicators from a loss or potential loss of fission barriers, as well as radiation monitoring, to ensure reactor and/or fission barrier events are recognized regardless of the particular EAL table a licensee may be referring to. EAL escalation is bounded by fission barrier indicators and EALs AA 1, AS1, and AG1.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.7 EAL SU8 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to ensure an EAL is declared when the plant has indications of primary coolant system (PCS) leakage. By design, this EAL is redundant with corresponding indicators from a loss or potential loss of fission barriers, as well as radiation monitoring, to ensure reactor and/or fission barrier events are recognized regardless of the particular EAL table a licensee may be referring to.

EAL escalation is bounded by fission barrier indicators and EALs AA 1, AS 1, and AG 1.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.5.8 EAL SS2 This EAL does not require an EAL set within the overall EAL scheme as the EAL's intent is to ensure an EAL is declared when a loss of DC power event occurs as it compromises the ability

- 17 of the licensee to monitor and control the removal of decay heat. The GE classification level for this event is bounded by fission barrier matrix indicators and EAL AG1.

The licensee chose to modify this EAL by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4), and therefore, is acceptable for implementation.

3.6 CATEGORY 'F' - FISSION BARRIER MATRIX This category is unique in the overall EAL scheme as the thresholds are not intended to be stand alone indicators of a particular event occurring at the site. Rather, they are to be used as triggers within the particular logic configuration needed to reflect a loss or potential loss of a fission barrier. Each licensee has three fission barriers: fuel cladding, the PCS, and the primary containment. Licensees are to develop thresholds that provide EAL decision-makers input into making an event declaration based upon degradation of one or more of these fission barrier barriers.

While there are only four EALs within this set (FG1/FS1/FA1/FU1), there are numerous triggers used as logic inputs to decide on the appropriate classification based upon the number of loss and/or potential loss indicators that are triggered for each barrier. By design, these indicators are redundant with other similar indicators in the Category fA' and Category'S' EAL sets due to importance of licensees being able to recognize reactor and/or fission barrier events as timely as possible using the best available indicators from several different perspectives.

The NRC staff verified that the logic used to determine the appropriate emergency classification is consistent with the generic EAL scheme development guidance.

The instrumentation and set points derived for this EAL category are consistent with the overall EAL scheme development guidance, address the site-specific implementation strategies provided, and are considered part of a standard EAL scheme.

The licensee chose to modify this EAL category by using a site-specific implementation method that uses a modified numbering format and EAL sequence other than that provided in the generic EAL scheme development guidance. The numbering, sequencing, and format of this EAL is consistent with the overall EAL scheme development guidance, is consistent with the site-specific implementation strategies provided, and is considered part of a standard EAL scheme.

The licensee specific implementation method for this EAL category is in alignment with the key characteristics of an effective EAL scheme, and while different than that provided in the generic

- 18 EAL development guidance, it continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4}, and therefore, is acceptable for implementation.

3.7

SUMMARY

The NRC staff has reviewed the technical basis for the proposed EAL scheme, the modifications from NEI 99-01, and the licensee's evaluation of the proposed changes to ensure the proposed EAL scheme continues to meet the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b)(4) and is consistent with the NE199-01 guidance.

The NRC staff's review has determined that the proposed EAL scheme is consistent with EAL schemes implemented at similarly designed plants, that it is uses objective and observable values, and that it is consistent with the guidance in NEI 99-01 in these areas.

The NRC staff's review has determined that the proposed EAL scheme is worded in a manner that addresses human engineering and user friendliness concerns. The proposed EAL scheme uses procedure language, including specific tag numbers for instrument readings and alarms, and flow charts, critical safety function status trees, check lists, and combinations of the above.

Based on this review, the NRC staff has concluded that the proposed EAL scheme is consistent with the guidance in NEI 99-01 in these areas.

The NRC staff's review has determined that the proposed EAL scheme is technically complete and that classification upgrades are based upon an increasing threat to public health and safety, can effectively support upgrading and downgrading, and follows a logical progression for multiple events. Based on this review, the NRC staff concludes that the EAL scheme is consistent with the guidance in NEI 99-01 in these areas.

The NRC staff review has also determined that the proposed EAL scheme is technically complete and accurate for each classification level. The proposed EAL scheme is based on risk assessment to set the boundaries of the emergency classification levels and assure that all EALs that trigger emergency classification are in the same range of relative risk. Precursor conditions of more serious emergencies also represent a potential risk to the public and are appropriately classified. The NRC staff has determined that the proposed EAL scheme is consistent with the guidance in NEI 99-01 in these areas.

The NRC staff reviewed EALs in each category, and each EAL set within that category, to determine whether the proposed EAL scheme meets the requirements of Section IV of Appendix E to 10 CFR Part 50 and 10 CFR 50.47(b}(4}, as well as be consistent with the NEI 99-01, Revision 5, generic guidance to the extent possible. Note that the licensee chose to modify their EAL scheme from NEI 99-01 to adopt a format more in alignment with how they currently implement their EALs, as well as alignment with licensee specific writer's guides and licensee preferences. The NRC staff determined that many of these modifications are administrative and/or minor in nature and do not alter the intent of any specific EAL within an EAL set, EAL category, or within the entire EAL scheme.

4.0 CONCLUSION

The NRC staff performed a technical and regulatory review of the proposed changes to the PNP EAL scheme and determined that the proposed changes meet the guidance in NEI 99-01,

5.0

- 19 Revision 5, the requirements of 10 CFR 50,47(b)(4), and the standards in Appendix E to 10 CFR 50. This determination considered the many site-specific modifications reviewed by the NRC staff. Based on this determination, the NRC staff concludes that the proposed EAL scheme provides reasonable assurance that the licensee can and will take adequate protective measures in a radiological emergency. Therefore, the NRC staff approves the proposed change to the EAL scheme.

REFERENCES

1.

Generic letter 79-50 dated October 10, 1979 (ADAMS Accession No. ML031320278).

2.

U.S. Nuclear Regulatory Commission and Federal Emergency Management Agency, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," NUREG-0654/FEMA-REP-1, November 1980 (ADAMS Accession No. ML040420012).

3.

Nuclear Management and Resources Council/National Environmental Studies Project (NUMARC/NESP) - 007, "Methodology for Development of Emergency Action Levels,"

Revision 2, dated January 1992 (ADAMS Accession No ML041120174).

4.

NEI 99-01 Revision 4, "Methodology for Development of Emergency Action Levels," dated January 2003 (ADAMS Accession No. ML041470143).

5.

Nuclear Energy Institute (NEI) 99-01, Revision 5, "Methodology for Development of Emergency Action Levels," February 2008 (ADAMS Accession No. ML080450149).

6.

U.S. Nuclear Regulatory Commission, "Emergency Planning and Preparedness for Nuclear Power Reactors," Regulatory Guide 1.101, Revision 2, dated October 1981 (ADAMS Accession No. ML090440294), Revision 3, dated August 1992 (ADAMS Accession No. ML003740302) and Revision 4, dated July 2003 (ADAMS Accession No. ML032020276).

7.

Miller, C. G., U.S. Nuclear Regulatory Commission, Letter to Alan Nelson, Nuclear Energy Institute, "U.S. Nuclear Regulatory Commission Review and Endorsement of NEI-99-01, Revision 5, dated February 2008," (ADAMS Accession No. ML080430535).

8.

Emergency Action Level Frequently Asked Question 2009-48, (ADAMS Accession No. ML100710728).

9.

U.S. Nuclear Regulatory Commission, Regulatory Issue Summary 2003-18, with Supplements 1 and 2, "Use of NEI-99-01, 'Methodology for Development of Emergency Action Levels,' dated January 2003," dated October 8,2003 (ADAMS Accession Nos. ML032580518, ML041550395, and ML051450482).

10.

NRC Bulletin 2005-02, "Emergency Preparedness and Response Actions for Security Based Events," dated July 18, 2005 (ADAMS Accession No. ML051740058).

- 20

11. NRC Regulatory Issue Summary 2006-12, "Endorsement of Nuclear Energy Institute Guidance "Enhancements to Emergency Preparedness Programs for Hostile Action","

(ADAMS Accession No. ML072670421).

12. Letter from Entergy Nuclear Operations, Inc., to U.S. Nuclear Regulatory Commission "NEI 99-01, Revision 5, "Methodology for Development of Emergency Action Levels, February 2008"," dated May 6,2010 (ADAMS Accession No. ML101440477).
13. Letter from Entergy Nuclear Operations, Inc., to U.S. Nuclear Regulatory Commission "Response to Request for Additional Information Re: Emergency Action Level Changes,"

dated March 9, 2011 (ADAMS Accession No. ML110750097).

Principal Contributor: D. A Johnson, NSIR/DPR Date: May 26,2011

Mr. Tom Kirwin May 26,2011 Vice President, Operations (Acting)

Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530 SUB~IECT:

PALISADES NUCLEAR PLANT - CHANGE TO EMERGENCY ACTION LEVEL SCHEME (TAC NO. ME3977)

Dear Mr. Kirwin:

By application dated May 6, 2010, and supplemented by letter dated March 9, 2011, Entergy Nuclear Operations, Inc., (the licensee), requested prior U.S. Nuclear Regulatory Commission (NRC) approval for proposed changes to the emergency action level (EAL) scheme for the Palisades Nuclear Plant (PNP). The requested changes support a conversion from their current EAL scheme to a scheme based on the Nuclear Energy Institute (NEI) 99-01, "Methodology for Development of Emergency Action Levels," Revision 5, dated February 2008. PNP currently utilizes an EAL scheme that is site-specific yet developed in accordance with the guidance provided in NEI 99-01, Revision 4, dated January 2003.

The NRC staff has completed its review. The NRC staff finds the proposed PNP EAL Scheme to be consistent with the guidance in NEI 99-01, Revision 5, and is an acceptable alternative for development of an EAL scheme that meets the standards in Title 10 of the Code of Federal Regulations (10 CFR) Section 50.47(b) and the requirements in 10 CFR Part 50, Appendix E, Section IV-B.

Therefore, the NRC staff approves the proposed change to the EAL scheme. A copy of the related Safety Evaluation is enclosed.

Sincerely, IRAJ Eric J. Leeds, Director Office of Nuclear Reactor Regulation Docket No. 50-255

Enclosure:

Safety Evaluation cc w/encl: Distribution via Listserv DISTRIBUTION: