ML111050037

From kanterella
Jump to navigation Jump to search
OL - TVA Letter to NRC_04-01-11_ Revised IPEEE RAI Responses
ML111050037
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 04/04/2011
From:
- No Known Affiliation
To:
Division of Operating Reactor Licensing
References
Download: ML111050037 (38)


Text

1 WBN2Public Resource From:

Boyd, Desiree L [dlboyd@tva.gov]

Sent:

Monday, April 04, 2011 7:44 AM To:

Epperson, Dan; Poole, Justin; Raghavan, Rags; Milano, Patrick; Campbell, Stephen Cc:

Crouch, William D; Hamill, Carol L; Boyd, Desiree L

Subject:

TVA letter to NRC_04-01-11_ Revised IPEEE RAI Responses Attachments:

04-01-11_ Revised IPEEE RAI Responses_Final.pdf PleaseseeattachedTVAletterthatwassenttotheNRCtoday.

ThankYou,

~*~*~*~*~*~*~*~*~*~*~*~*~*~*~

Désireé L. Boyd WBN2LicensingSupport SunTechnicalServices dlboyd@tva.gov 4233658764

~*~*~*~*~*~*~*~*~*~*~*~*~*~*~

Hearing Identifier:

Watts_Bar_2_Operating_LA_Public Email Number:

308 Mail Envelope Properties (7AB41F650F76BD44B5BCAB7C0CCABFAF1D4B835F)

Subject:

TVA letter to NRC_04-01-11_ Revised IPEEE RAI Responses Sent Date:

4/4/2011 7:43:49 AM Received Date:

4/4/2011 7:44:06 AM From:

Boyd, Desiree L Created By:

dlboyd@tva.gov Recipients:

"Crouch, William D" <wdcrouch@tva.gov>

Tracking Status: None "Hamill, Carol L" <clhamill@tva.gov>

Tracking Status: None "Boyd, Desiree L" <dlboyd@tva.gov>

Tracking Status: None "Epperson, Dan" <Dan.Epperson@nrc.gov>

Tracking Status: None "Poole, Justin" <Justin.Poole@nrc.gov>

Tracking Status: None "Raghavan, Rags" <Rags.Raghavan@nrc.gov>

Tracking Status: None "Milano, Patrick" <Patrick.Milano@nrc.gov>

Tracking Status: None "Campbell, Stephen" <Stephen.Campbell@nrc.gov>

Tracking Status: None Post Office:

TVANUCXVS2.main.tva.gov Files Size Date & Time MESSAGE 326 4/4/2011 7:44:06 AM 04-01-11_ Revised IPEEE RAI Responses_Final.pdf 1316042 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 April 1, 2011 10 CFR 50.4 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 2 NRC Docket No. 50-391

Subject:

Watts Bar Nuclear Plant (WBN) Unit 2 - Individual Plant Examination of External Events Design Report (IPEEE) - Response to Requests for Additional Information - Revised

Reference:

1. TVA letter dated December 17, 2010, Watts Bar Nuclear Plant (WBN) Unit 2

- Individual Plant Examination of External Events Design Report (IPEEE) -

Response to Requests for Additional Information

2. TVA letter dated February 17, 1998, Watts Bar Nuclear Plant (WBN) Unit 1 -

Generic Letter 88-20, Supplements 4 and 5 - Individual Plant Examination of External Events (IPEEE) for Severe Accident Vulnerabilities (TAC No.

M83693)

This letter provides revised responses to requests for additional information (RAIs) Nos., IPS-1f and IPO-2, previously provided in Reference 1. Further discussions with the staff during a telecon on March 11, 2011, created the need to provide these revised responses. In addition, this letter also provides a response to a new NRC RAI received during the telecon involving the definition of vulnerability used for the IPEEE Fire analysis. Enclosure 1 provides both the revised responses with revision bars indicating the changes along with the response to the new RAI.

To facilitate staff review, Enclosure 2 provides Attachment 5 of the report previously provided in Reference 2. Enclosure 1 refers to Attachment 5 to supplement the answer to RAI IPO-2.

This letter does not contain any new commitments. If you have any questions, please contact Bill Crouch at (423) 365-2004.

U.S. Nuclear Regulatory Commission Page 3 April 1, 2011 cc (Enclosures):

U. S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303-1257 NRC Resident Inspector Unit 2 Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381

U.S. Nuclear Regulatory Commission Page 2 April 1, 2011 bcc (Enclosures):

Stephen Campbell U.S. Nuclear Regulatory Commission MS 08H4A One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 Charles Casto, Deputy Regional Administrator for Construction U. S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303-1257

ENCLOSURE 1 Tennessee Valley Authority - Watts Bar Nuclear Plant - Unit 2, Docket No. 50-391 Revision to Previously Provided Responses to RAI Questions IPS-1f and IPO-2 and Response to New RAI E1-1 SEISMIC EVENTS IPS - 1f For the WBN1 Individual Plant Examination (IPE) your definition of vulnerability was in terms of contribution to core damage frequency. What is your definition of vulnerability for the Seismic Margin Analysis you carried out for the WNB2 IPEEE, and have you found any seismic vulnerabilities?

Response

Watts Bar Units 1 and 2 is a focused scope plant with a 0.3g review level earthquake per NUREG-1407. Identification of seismic vulnerabilities is performed based on the criteria and guidelines of the EPRI Seismic Margin methodology (EPRI Report No. NP-6041).

Consistent with the U1 IPEEE approach, a potential vulnerability would be identified as any component identified on the Safe Shutdown Equipment List (SSEL) for which the HCLPF capacity is computed as less than 0.3g.

Results will be reported consistent with that reported for Unit 1, as shown in Table 2.2 of the Unit 2 IPEEE Design Report (Reference 2). No vulnerabilities have been identified to date.

Note that based on further analysis, a revised HCLPF capacity of 0.52g has been established for Main Control Room (MCR) ceiling, rather than the Unit 1 value of 0.36g in Table 2.2 of the Unit 2 IPEEE Design Report (Reference 2).

OTHER EXTERNAL EVENTS IPO - 2 What is your definition of vulnerability for the Other External Events analysis of WBN2, and have you found any vulnerabilities from the Other External Events analysis?

Response

In accordance with GL 88-20 and NUREG-1407, the other external events analysis is a confirmation of compliance with the 1975 NUREG-0800 Standard Review Plan (SRP).

Consequently, the definition of vulnerabilities from the other external events would be the identification of a structure system or component that is not in compliance with the 1975 SRP.

No vulnerabilities have been identified to date. Please note that as described in Section 3.2 of the Unit 2 IPEEE Design Report (Reference 2), TVA is currently re-establishing probable maximum flood (PMF) levels for all sites. Any increase in PMF elevation for Unit 2 will be handled as a design issue and not within IPEEE.

ENCLOSURE 1 Tennessee Valley Authority - Watts Bar Nuclear Plant - Unit 2, Docket No. 50-391 Revision to Previously Provided Responses to RAI Questions IPS-1f and IPO-2 and Response to New RAI E1-2 NRC requested in the telecon of March 11, 2011, for a more detailed comparison of WBN U2 design requirements and the requirements of the 1975 SRP to supplement the previous discussion above. Enclosure 2 provides a document entitled, Attachment 5, Watts Bar Nuclear Plant (WBN) - Individual Plant Examination for External Events - High Winds, Floods, and Other External Events. This document is from the Other External Events section of the Unit 1 IPEEE Report previously provided in Reference 2. It provides this same kind of comparison for Unit 1 and, with the exception noted above regarding PMF, is equally applicable to Unit 2 design requirements since the Unit 2 IPEEE approach is the same as Unit 1.

New NRC RAI: What definition of vulnerability was used for the IPEEE Fire analysis?

Response: The IPEEE uses the Fire Induced Vulnerability Evaluation (FIVE) methodology for evaluating the plant vulnerability to fires. The screening criteria was 1.0E-6 for a given fire area. If the probability of core damage was greater than 1.0E-6, then it would have been classified as a vulnerability.

ENCLOSURE 2 Excerpt entitled, Attachment 5 - Watts Bar Nuclear Plant (WBN) - Individual Plant Examination for External Events - High Winds, Floods, and Other External Events E2-1