ML102150104

From kanterella
Jump to navigation Jump to search

And Peach Bottom Limited Senior Reactor Operator (Lsro) - Draft- Outlines (Folder 2)
ML102150104
Person / Time
Site: Peach Bottom, Limerick  
(DPR-044, NPF-039, NPF-085, DPR-056)
Issue date: 06/06/2010
From: Dickenson R, Wasong A
Exelon Generation Co
To: D'Antonio J
Operations Branch I
HANSELL S
Shared Package
ML092470056 List:
References
TAC U01795, TAC U01796
Download: ML102150104 (12)


Text

ES-701 LSRO BWR Written Examination Outline Form ES-701-1 LGS Date of Exam: Ju 19 2010 Tier K1 K2 K3

_,;mc,nn.n.1 Points A2 A3 A4 G

Total

1.

Emergency &

Abnormal Plant Evolutions 2

2 1

2 10

2.

Plant 2

1 2

1 2

2 2

20

3. Generic Knowledge and 1

4 GFE Abilities Categories 10 2

2 2

2 Note:

1.

Ensure that at least one topic from every KIA category is sampled within each tier.

2.

The point total for each tier in the proposed outline must match that specified in the table. The final point total for each tier may deviate by +/-1 from that specified in the table based on NRC revisions. The final exam must total 40 points.

3.

Select topics from many systems and evolutions; avoid selecting more than two KIA topics from a given system (except fuel handling equipment) or evolution (except refueling accident).

4.

The shaded areas are not applicable to the category/tier.

5.*

The generic (G) KlAs in Tiers 1 and 2 shall be selected from Section 2 of the KIA Catalog, but the topics must be relevant to the applicable evolution or system.

6.

If the applicants have not previously taken the GFE, Tier 3 shall include basic: reactor theory, component, and thermodynamic topics that apply to fuel handling operations.

7.

Systems/evolutions within each tier are identified on the associated outline.

Enter the KIA numbers, a brief description of each topic, the topics' importance ratings (IR) for the SRO license level, and the point totals (#) for each system and category. Enter the tier totals for each category in the table above.

8.

For Tier 3, select topics from Section 2 of the KIA catalog, and enter the KIA numbers, descriptions, importance ratings, and point totals (#) on Form ES-701-3.

9.

Refer to ES-401, Section 0.1, for guidance regarding the elimination of inappropriate KIA statements. The facility licensee's JTA for fuel handlers should be used as the basis for eliminating or adding testable topics.

ES-701 LSRO BWR Written Examination Outline Form ES-701-1 Emergency and Abnormal Plant Evolutions - Tier 1 K

K K

A A

G KJA Topic(s)

IR 1

2 3

1 2

295003 Partial or Complete Loss of AC X

AK1.04, Electrical bus divisional separation 3.2 1

295004 Partial or Total Loss of DC 295014 Inadvertent Reactivity Addition AK2.07. Reactor Power 3.9 1

295018 Partial or Total Loss of CCW AA 1.01, Backup systems 3.4 1

295021 Loss of Shutdown Cooling X G2.2.42, Ability to recognize system parameters that 1

are entry-level conditions for Technical SpeCifications.

295023 Refueling Accidents 295033 High Secondary Containment X

EK1.02. Personnel protection 4.2 1

Area Radiation Levels 295034 Secondary Containment X

EA2.01, Area radiation levels 4.2 1

Ventilation High Radiation 295006 SCRAM X

AA2.02, Control rod position 4.4 1

295008 High Reactor Water Level 295009/295031 Reactor Low Water X

EK2.03, Low pressure core spray 4.3 1

Level 295017/295038 High Oftsite Release Rate 295019 Partial or Total Loss of Inst. Air X

AA 1.02, Instrument air system valves 3.1 1

295020 Inadvertent Cant. Isolation 295030 Low Suppression Pool Wtr Lvi I

mx 295035 Secondary Containment High Differential Pressure i

600000 Plant Fire On Site X

AK3.04. Actions contained in the abnormal procedure 3.4 1

for plant fire on site i

[

tegory Totals:

2 2

1 2 I 2 1

Tier Point Total:

W

ES-701 LSRO BWR Examination Outline Form ES-701-1 Plant Systems - TIer 2 K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

KIA Topic(s)

IR 205000 Shutdown Cooling X

K1.15, RHR service water 3.6 1

215004 Source Range Monitor X

K2.01, SRM channels/detectors 233000 Fuel Pool Cooling/Cleanup X 2.1.45, Ability to identify and interpret diverse indications to validate the response of another indication.

4.3 1

234000 Fuel Handling Equipment X

A2.01, Interlock failure 3.7 1

262001 AC Electrical Dist.

X A3.02, Automatic bus transfer

~,.3 1

263000 DC Electrical Dist.

290002 Reactor Vessel Internals X

K4.05, Natural circulation

.5 1

201002 RMCS X

A4.01, Rod movement control switch

,.4 1

201003 Control Rod and Drive Mechanism X

K4.01, Limiting control rod speed in the event of a rod drop

,.0 1

203000 RHA/LPCI:

Injection Mode X

K3.01, Reactor water level 4.4 1

204000 RWCU A4.01, System pumps 3.0 1

211000 SLC A 1.08, RWCU system lineup

..8 1

212000 RPS KS.02, Specific logic arrangements

,.4 1

214000 RPIS 215001 Traversing In-Core Probe 21S0031RM X

A3.03, RPS status 3.6 1

21500S APRM I LPRM 223001 Primary CTMT and Aux.

223002 PCIS/Nuclear Steam Supply Shutoff K6.06, Various process instrumentation 2.9 1

261000 SGTS X

A 1.01, System flow 3,.1 1

264000 EDGs X

K3.01, Emergency core cooting systems 4.4 1

272000 Radiation Monitoring X 2.4.11, Knowledge of abnormal condition procedures 4.2 1

286000 Fire Protection 288000 Plant Ventilation X

K5.01, Airborne contamination control 3.2 1

290001 Secondary CTMT X

K1.04, SBGT 3.9 1

300000 Instrument Air 400000 Component Cooling Water X

K6.06, Heat exchangers and condensers 2.9 1

KlACa 2

1 I 2 2

2 "

2 oint Total:

2"

ES-701 LSRO BWR Written Examination Outline Form ES-701-1 Faci PBAPS Date of Exam: Ju 192010 Points Tier K1 K2 K3 A2 A3 A4 G

Total

1.

1 1

0 2

1 Emergency &

5 Abnormal Plant Evolutions

2.

1 0

1 0

0 1

0 1

0 0

1 Plant 5

3. Generic Knowledge and 1

2 3

4 GFE Abilities Categories 0

0 0

0 0

0 Note: 1.

Ensure that at least one topic from every KIA category is sampled within each tier.

2.

The point total for each tier in the proposed outline must match that specified in the table. The final point total for each tier may deviate by +/-1 from that specified in the table based on NRC revisions. The final exam must total 40 points.

3.

Select topics from many systems and evolutions; avoid selecting more than two KIA topics from a given system (except fuel handling equipment) or evolution (except refueling accident).

4.

The shaded areas are not applicable to the category/tier.

5.*

The generic (G) KlAs in Tiers 1 and 2 shall be selected from Section 2 of the KIA Catalog, but the topics must be relevant to the applicable evolution or system.

6.

If the applicants have not previously taken the G FE, Tier 3 shall include basic reactor theory, component, and thermodynamic topics that apply to fuel handling operations.

7.

Systems/evolutions within each tier are identified on the associated outline.

Enter the KIA numbers, a brief description of each topic, the topics' importance ratings (IR) for the SRO license level, and the point totals (#) for each system and category. Enter the tier totals for each category in the table above.

8.

For Tier 3, select topics "from Section 2 of the KIA catalog, and enter the KIA numbers, descriptions, importance ratings, and point totals (#) on Form ES-701-3.

9.

Refer to ES-401, Section D.1, for guidance regarding the elimination of inappropriate KIA statements. The facility licensee's JTA for fuel handlers should be used as the basis for eliminating or adding testable topics.

ES-701 LSRO BWR Written Examination Outline Form ES-701-1 Emergency and Abnormal Plant Evolutions - Tier 1 K

K K A A G KJA Topic(s)

IR 1

2 3

1 2

295003 Partial or Complete Loss of AC X

AK1.04, Electrical bus divisional separation 3.2 1

295004 Partial or Total Loss of DC 295014 Inadvertent Reactivity Addition 295018 Partial or Total Loss of CCW 295021 Loss of Shutdown Cooling X G2.2.42, Ability to recognize system parameters that 4.6 1

are entry-level conditions for Technical Specifications.

295023 Refueling Accidents 295033 High Secondary Containment Area Radiation Levels 295034 Secondary Containment X

EA2.01, Area radiation levels 4.2 1

Ventilation High Radiation 295006 SCRAM X

AA2.02, Control rod position 4.4 1

295008 High Reactor Water Level 295009/295031 Reactor Low Water X

EK2.03, Low pressure core spray 4.3 1

Level 295017/295038 High Offsite Release Rate 295019 Partial or Total Loss of Inst. Air 295020 Inadvertent Cant. Isolation 295030 Low Suppression Pool Wtr Lvi 295035 Secondary Containment High Differential Pressure 600000 Plant Fire On Site KJA Category Totals:

1 1

0 0

2 1

Tier Point Total:

5

ES-701 205000 Shutdown Cooling 215004 Source Range lVIonitor 233000 Fuel Pool Cooling/Cleanup oFuel Handling ment 262001 AC Electrical Dist.

263000 DC Electrical Dist.

290002 Reactor Vessel Intemals 201002 RMCS 201003 Control Rod and Drive Mechanism 203000 RHRlLPCI:

Injection Mode 204000 RWCU 211000 SLC 212000 RPS 214000 RPIS 215001 Traversing In-Core Probe 2150031RM 215005 APRM / LPRM 223001 Primary CTMT and Aux.

223002 PCIS/Nuclear Steam Supply Shutoff 261000 SGTS 264000 EDGs 272000 Radiation Monitoring 286000 Fire Protection 288000 Plant Ventilation 290001 Secondary CTMT 300000 Instrument Air 400000 Component Cooling Water LSRO BWR Examination Outline Form ES-701-1 Plant Systems - Tier 2 K

K K K K K A A A A G KiA Topic(s)

IR 1

2 3

4 5

6 1

2 3

4 X

K1.15, RHR service water 3.6 1

X A2.01, Interlock failure 3.7 1

I I K6.06, Various process instrumentation 2.9 1

K3.01, Emergency core cooling systems 4.4 1

00 X

X 2.4.11, Knowledge of abnormal condition 4.2 1

procedures

~/f\\,"",

'"1 Totals:

1~

5

LSRO Generic KrIVVYIt:U~!;: and Abilities Outline (Tier 3)

Form ES-701-3 ility:

LGS Date of Exam:

July 19 2010 C:ltAnnry KIA #

I()pic IR 2.1.3 Knowledge of shift or short-term relief turnover 3.9 1

prar.tir.A<::.

1.

2.1.29 Knowledge of how to conduct system lineups, 4.0 1

Conduct of such as vdlv6S, b,'eaker's, "vVitches, etc.

Operations 2.1.

2.1 Subtotal

~2 2.2.39 Knowledge of less than or equal to one hour 4.5 1

Technical Specification action statements for

2.
)Y;
)Lt:::III;:).

Equipment 2.2.3 (multi-unit license) Knowledge of the design, 3.9 1

Control procedural, and operational differences between units.

2.2.

2.2.

RllhtotAI

~ 2 2.3.15 Knowledge of radiation monitoring systems, such 3.1 1

as fixed radiation monitors and alarms, portable

3.

survey instruments, personnel monitoring Radiation Control equipment, etc.

2.3.12 Knowledge of radiological safety principles 3.7 1

pertaining to licensed operator duties, such as containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

2.3.

2.3.

Subtotal 2

2.4.40 Knowledge of SRO responsibilities in emergency ~ 1 plan implementation.

4.

2.4.28 Knowledge of procedures relating to a security 4.1 1

Emergency event (non-safeguards information).

Procedures /

2,4..

Plan

2,4..

§LJR!otal

.,.'./...:';;1" 2

291003 Function and operation of flow controller in 3.7 1

K1.01 manual and automatic modes

5.

292002 Evaluate change in shutdown margin due to 2.9 1

Generic K1.14 changes in plant parar. Itat:H l:i Fundamentals Subtotal i";..*.*.:. 2

.*.*.* *****.i<i*

Tier 3 Point Total

I ES-701 LSRO Generic Knowledge and Abilities Outline (Tier 3}

Form ES-701-3 I I Facility:

PBAPS Date of Exam:

July 192010 I Category KIA #

2.1.

1.

Conduct of 2.1.

Operations 2.1.

2.1.

Subtotal 2.2.

2.

Equipment 2.2.

Control 2.2.

2.2.

Subtotal 2.3.

3.

Radiation 2.3.

Control 2.3.

2.3.

Subtotal 2.4.

4.

Emergency 2.4.

Procedures /

2.4.

Plan 2.4.

Subtotal

5.

Generic Fundamentals Subtotal Tier 3 Point Total Topic IR i@;~il;~iiri;jiii~

iii:l¥l~:j)i!.

0 ii 0

!;jii0+::f"i':l,y!i";:" 0 f:i:!;t::;::.it~~i;i~iii 0

.i 0

ES-701 LSRO Operating Test Outline Form E5-701-4 Applicant Docket Number: 55-352/353 Page 2 of Facility: LGS Date of Examination: July 1!~ 2010 Title I Description of Tasks (JPMs)

Type Evaluation Comment Page Codes*

(S or U)

Number Administrative

1. FHD turn over checklist NT
2. GP-13, CRD, CRB and Maintenance I'J Coordination 1Alternate Path - Two cell separation not ensured I 3. Calculate Stay Time (2701)

DL Systems

1. Fuel Movement in the Spent Fuel Pool /

DAI Alternate Path - HOIST JAM Light Illuminates (2035)

2. Fuel movement in the Spent Fuel Pool /

NAI Alternate Path - Hoist Tube Hang Up

3. Refuel Floor ARM Return to Service NI
4. Install rod position test box (2029)

OIL i

EmergencylAbnormal Plant Evolutions

1. New Fuel Movement in the Spent Fuel Pool MAIR from fuel prep machine / Alternate Path New Fuel Drops
2. Spent Fuel Pool Makeup using Fire System NIR standpipes per TSG-4.1
3. Emergency Classification, Inability to NR Maintain Cold shutdown Type Codes &Criteria:

(A)lternative path (2 systems; 1 ElAPE)}

(C}ontrol room (D)irect from bank (S 7)

(I)n-plant (N}ew or (M)odified from bank including 1 (A) (~ 1 1section)

(L}ast NRC exam (S 11 section)

(R)efueling accident (1)

(T)echnical specification (~2)

ES-701 LSRO Operating Test Outline Form ES-701-4 Applicant Docket Number: 50-277/278 Pa!Je 2 of Facility: PBAPS Date of Examination:

July 192010 Title / Description of Tasks (JPMs)

Type Evaluation Comment Page Codes*

(S or U)

Number Administrative

1.
2.
3.

Systems

1. Skimmer Surge Tank Low Levell Alternate MAl Path - Pump Trip (3054)
2. Fuel Support Piece Removal using FSP NAI Grapple 1Alternate Path - Fault Lockout
3. Transfer of Recently Irradiated Fuel 1 I\\JTAI Alternate Path - Loss of SBGT
4. PBAPS Refuel Platform Air System NI Checkout Emergency/Abnormal Plant Evolutions
1. Dummy Fuel Movement in Spent Fuel Pool MAl 1Alternate Path - Fire (3064)
2.
3.

Type Codes & Criteria:

(A)lternative path (2 systems; 1 ElAPE))

(C)ontrol room (D)irect from bank (:5 7)

(I)n-plant (N)ew or (M)odified from bank including 1 (A) (~ 1 1section)

(L)ast NRC exam (:5 1 / section)

(R)efueling accident (1)

(T)echnical specification (~ 2)

ES-401 Record of Rejected KI As Form ES-401-4 Tier /

Randomly Reason for Rejection Group Selected KIA TIER 1 295014 AK2.07 PBAPS outline - Knowledge of the interrelations between INADVERTENT REACTIVITY ADDITION and the following: Reactor Power: Inadvertent Reactivity Addition.

Although this KIA can be adequately tested within the LSRO job scope these is no difference between LGS and PBAPS.

This KIA was rejected and was replaced with randomly selected KIA 295009 EK2.03 which was verified to be contained within the LSRO job scope and contain a testable difference.

TIER2 214000 A4.02 LGS and Common Outline* Ability to manually operate and/or monitor in the control room: Control rod position Too closely related to previously selected Tier 1 295006 AA2.02: Ability to determine and/or interpret the following as they apply to SCRAM: Control rod position This KIA was rejected and was replaced with randomly selected KIA 204000 A4.01, which was verified to be contained within the LSRO job scope, and did not overlap with previously selected KIA TIER2 215001 LGS and Common Outline* 215001 Traversing In-Core Probe. Ability to monitor automatic operations of the TRAVERSING IN-CORE PROBE Traversing In-Core Probe operations are conducted at power, and would not be contained within the LSRO job scope.

This KIA was rejected and was replaced with randomly selectt3d KIA 215003 A3.03, which was verified to be contained within the LSRO job scope.

TIER2 233000 2.1.38 LGS and Common Outline - 2.1.38 knowledge of the station's requirements for verbal communications when implementing procedures.

There are no specific responsibilities for LSROs regarding FPCC procedure use that could be used to test communication when implementing procedures.

This KIA was rejected and was replaced with randomly selected 233000 2.1.40 which was verified to be contained within the LSRO job scope TIER 1 295035 EA 1.01 LGS and Common Outline - Ability to operate and/or monitor the following as hey apply to SECONDARY CONTAINMENT HIGH DIFFEFtENTIAL PRESSURE: Secondary containment ventilation system There are no realistic failure mechanism related to plant conditions that are present during LSRO activities that could plausibly result in SE~condary Containment high dP.

This KIA was rejected and was replaced with randomly selected TIER 1 295018 AA 1.01 which was verified to be contained within the LSRO job scope reselected

LGS and Common Outline* Knowledge of EOP mitigation strategies TIER 3 2.4.6 There are no EOP entries, and consequently mitigation strategies related to plant conditions that are present during LSRO activities.

This KIA was rejected and was replaced with randomly selected 2.4.40 which was verified to be contained within the LSRO job SCOpH reselected