Calculation PBNP-994-21-05-P05, Rev. 0, Steam Supply Piping to AFW Pump GL 87-11, Break Location Determination, Enclosure 1, Attachment 7
ML101940375
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 10/03/2008
From: Kandalepas C
Automated Engineering Services Corp
To:
Florida Power & Light Co, Office of Nuclear Reactor Regulation
References
GL-87-011 PBNP-994-21-05-P05, Rev. 0
Download: ML101940375 (22)


Text

ENCLOSURE I ATTACHMENT 7 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 LICENSE AMENDMENT REQUEST 261 EXTENDED POWER UPRATE RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION PBNP-994-21-05-P05, REVISION 0, STEAM SUPPLY PIPING TO AFW PUMP GL 87-11 BREAK LOCATION DETERMINATION 21 pages follow

Page: 4 of 17 Calc. No.: PBNP-994-21-05-P05 Revision: 0 U1i~nf Florid~i Power & light Station: Point Beach Nuclear Plant - Unit I Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes N]

No El Date: 10/03/2008 TABLE OF CONTENTS Page No.

1.0 Purpose........................................................................................................................................................

5 2.0 Background....................................................................................................................................................

5 3.0 Assumptions and Analysis:N otes........................................................................................................

6 4.0 M ethodology and Acceptance Criteria.................................................................................................

. 7 5.0 References.................................................................................................................................................

11 6.0 GL 87-11 Break And Leak Location Calculations.................................................................................

12 7.0 Results & Conclusions...............................................................................................................................

16 Attachments Pages A.

Stress Indices, Resultant Stress Calculation Tables, Stress Tables........................................

Al-A3 B.

SK -FW -FIG.2 - Postulated Line Break Locations...................................................................

B I C.

A ES Technical Position Paper for H ELB Program................................................................

C 1-C3 Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

Page: 5 of 17 Cale. No.: PBNP-994-21-05-P05 Revision: 0 Client:

Florida Power & Light Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Cale.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes ERJ No DI Date: 10/03/2008 1.0 PURPOSE The purpose of this calculation is to establish the locations of intermediate high energy large breaks and leakage cracks utilizing the criteria given in Generic Letter 87-1 1 and its attachment USNRC Mechanical Engineering Branch Technical Position, MEB 3-1, Revision 2 (Reference 3).

Combined stress tables for the 3" steam supply piping from the Main Steam headers to Auxiliary Feedwater (AFW) Pump IP-29 are developed for the sole purpose of determining the locations of intermediate large breaks and leakage cracks in accordance with the combined stress equations defined in Reference 3.

This calculation determines break and crack locations in the high-energy lines outside containment, based on the combined stress criteria detailed in the GL 87-11 methodology. This calculation does not address the additional postulation of "a single crack, exclusive of stress, at the most severe location with respect to essential equipment" (11 Notice 2000-20, Reference 9), nor does this calculation address the consequences of or evaluate the impacts of breaks or cracks that are required to be postulated based on this criteria.

2.0 BACKGROUND

PBNP's licensing basis for High-Energy Line Break (HELB) is documented in the Final Safety Analysis Report (FSAR) (Reference 2, Appendix A.2). Appendix A.2 of the FSAR defines a high-energy line as a line with design pressure greater than 275 psig and service temperature greater than 200'F. Both conditions have to be satisfied for a line to be designated high-energy. Additional background discussion regarding the BPNP HELB Program and details for establishing HIELB break and leakage crack locations criteria (HELB Reconstitution Program) is provided in the AES technical position paper (see Attachment C).

Based on the above high energy line definition, Calculation PBNP-994-21-02 (Reference 13) identifies the Main Steam (MS) System Lines, Main Feedwater Piping, Steam Generator (SG) Blowdown Piping, and Sampling System Lines as high-energy lines (Reference 2, Appendix A.2).

The application of GL 87-11 methods to determine the new intermediate break and leakage crack locations is expected to be beneficial in addressing design concerns related to high energy line break effects. GL 87-1 1 still requires terminal end circumferential breaks to be postulated irrespective of the combined stress values at these locations.

Since the purpose of this calculation is only to generate stress tables to determine GL 87-11 break and or crack locations, the pipe stress analyses for the steam supply piping (Reference 6) still remain valid.

Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2 -"

Page:

6 of 17 Client:

Florida Power & Light Calc. No.: PBNP-994-21-05-POS Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes

[]

No 0i Date: 10/03/2008 3.0 ASSUMPTIONS AND ANALYSIS NOTES Assumptions Piping material, geometric data and stress analysis (computer results) given in the Analysis of Record (AOR)

(Reference 6) for the Steam Supply piping to the AFW Pump are used as input to develop the GL 87-11 combined stress tables that, in turn, are used to determine the intermediate break and leakage crack locations.

Analysis Notes The code of record for this plant is USAS B3 1.1 Power Piping Code, 1967 Edition (Reference 1). The Steam Supply piping stress analysis documented in Reference 6 was performed using ASME B&PV Code, Section Ill, Subsection NC and ND, 1977 Edition up to and including 1978 Winter Addenda (Reference 10). A pipe code reconciliation study was used to show that no significant differences exist between the two codes for piping analysis.

Application of the MEB 3.1, Rev. 2 methodology for Class 2 and 3 piping requires combined stresses to be calculated in accordance with the 1986 ASME Section II1, Class 2 requirements (Reference 4). Because the way stresses are factored in the two codes is different, the individual load components (moments) for the different load cases (weight, pressure, thermal, and OBE seismic) fi'om the AOR are extracted and adjusted for the stress indices and stress intensification factors, and used as input to calculate the new combined stresses in accordance with Reference 4.

Stress Intensification Factors (SIFs) that are calculated per Reference 10 are identical to those calculated per Reference 4. As such, SIFs fi'om the analysis in Reference 6 are used in the calculations of secondamy stresses per Reference 4. These SIFs appear in the stress tables. Note that SIF is not specified at every point in the existing piping analysis. SIFs are equal to 1.0 for those locations without SIF specifically identified.

Factored stresses, calculated based on Reference 4, uses SIF and stress indices, B, and B2. These stress indices are determined / calculated in accordance with Table NB-3681 (a)-1 and associated sections of Reference 4.

Stress indices for straight pipe runs are obtained from Table NB-3681 (a)-] (Reference 4) and they are B1 =

0.5 and B2 = 1.0.

Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

I Automated Engineering CALCULATION SHEET Page:

7 of 17 Services Corp Cale. No.: PBNP-994-21-05-P05 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes E]

No D

Date: 10/03/2008 4.0 METHODOLOGY AND ACCEPTANCE CRITERIA This calculation uses the GL 87-11 (Reference 3) methodology to determine postulated pipe break and crack locations.

The analysis in Reference 6 was performed using ASME Section 111, Subsection NC and ND, 1977 Edition (Reference 10) as the piping code. The results from this analysis are used to calculate the combined stresses using the methodology in ASME Section III, 1986 Edition (Reference 4) consistent with GL 87-11 criteria.

All stress components for the ASME Section IlIstress combination, except longitudinal pressure stress, are obtained from the AOR. The resultant stresses along with appropriate stress indices, "Bl" and "B2" and the stress intensification factor (SIF) T' values used in the calculation of the stress components in equations (1) and (2) are given in Section 4.1 and 4.3 ofthis calculation.

The following is a discussion of the high-energy line break criteria used to establish the break locations using the GL 87-11 methodology.

4.1 Intermediate Large Breaks The GL 87-11 and MEB 3-1, Revision 2 criteria (Reference 3) for intermediate large breaks is based on the combined stress formula given by the sum of Equations 9 and 10 ofASME B&PV Code Section III, Class 2 and 3 as follows:

B, PDd/2t + B2 Mow/Z + B2 Mo8J/Z + i MTm/Z > 0.8 (1.8 Sh + SA)

(1)

In above equation, the first term is the longitudinal pressure stress. The resultant stresses (MIZ) for each load case (deadweight, thermal expansion, and OBE from simultaneous X and Y directions or OBE from simultaneous Y and Z directions) are calculated on the resultant stress calculation Table in Attachment A based on the moments in X, Y and Z (MA, MB, Mc) directions obtained from the AOR (Reference 6).

S = [(MA2 + MB2 + Mc 2)1/2] / Z To obtain the corresponding ASME Section III factored stresses for the deadweight and seismic load cases, the stresses obtained from the resultant stress calculation Table in Attachmcnt A, are multiplied by the corresponding B2 values. Note that thermal expansion stresses are multiplied by the SIF (i).

Replacing the MIZ term by S, the modified combined stress equation is as follows; B1 PD0/2t + B2 SDw + B2 SOBE + i ST2! 0.8 (1.8 Sh + SA)

(1A)

Where:

P

= Design internal pressure, psi Do

= Outside diameter of the pipe, in Form 3.1-3

~.Rev.2 Form 3.1-3

.. Rev. 2

Page: 8 of 17 Cale. No.: PBNP-994-21-05-P05 Revision: 0 i

IClient:

Florida Power & Light Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes NI No El Date: 10/03/2008 t

= Nominal thickness of the pipe, in MDW

= Resultant moment due to dead weight, in-lbs MOBE

= Resultant moment due to operating basis earthquake, in-lbs MTH

= Resultant moment due to thermal expansion, in-lbs SDw

= Resultant stress due to dead weight, psi, from Resultant Stress Table in Attachment A SOBE

= Resultant stress due to OBE (Max of X & Y or Y & Z earthquake), psi, from Resultant Stress Table in Attachment A STH

= Resultant stress due to thermal expansion, psi, from Resultant Stress Table in Attachment A Sh,

= Material allowable stress at temperature, psi SA

= Material allowable stress range, psi Z

= Section modulus-of pipe, in3 i

= stress intensification factor, as given in Figure NC-3673.2(b)-I B,

= primary stress index for pressure stress as given in Table NB-3681(a)-I and further defined in Section 4.4 B2

= primamy stress index for bending stresses as given in Table NB-3681 (a)-1 and further defined in Section 4.4 Large intermediate breaks are to be postulated only at locations where the combined stress exceeds the threshold value of 0.8(1.8Sh, + SA) (Reference 3). The requirements for arbitrary intermediate large breaks are eliminated by Reference 3.

4.2 Circumferential Breaks at Terminal Ends of Main and Branch Lines Terminal Ends The GL 87-11 criteria state that circumferential breaks have to be postulated at terminal ends of the main run as well as the branch piping. Terminal ends of a piping run are defined as the ends terminating at components, or at other piping (run pipe), or at intermediate anchors. Footnote 3 of MEB 3-1, Rev. 2 provides a definition for the term "terminal ends" which was missing in the Giambusso letter (Reference 5). The footnote defines terminal ends as "Extremities of piping runs that connect to structures, components (e.g., vessels, pumps, valves), or pipe anchors that act as rigid constraints to the piping motion and thermal expansion. A branch connection to a main piping run is a terminal end of the branch run, except where the branch run is classified as part of the main run and is shown to have a significant effect on the main run behavior..."

Terminal ends for the Steam Supply piping to AFW Pump I P-29 are summarized on Table 7.1 (Section 7.0).

Forni3.1-3 Rev. 2.

Form-3.1-3 Rev. 2-

Automated Enginering CALCULATION SHEET Page: 9 of 17 Ler sCorp Calc. No.: PBNP-994-21-05-P05 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes 0

No D]

Date: 10/03/2008 Branch Lines The 3" steam supply piping to AFW pump IP-29 is modeled and analyzed in a separate analytical part (Ref. 6) from the Main Steam header piping. These lines are affected by and in turn affect the main li ne, and as such, the branch connections to the Main Steam header (Node Points 16 & GIS) are considered terminal ends.

4.3 High-Energy Line Leakage Cracks (Small Breaks)

The GL 87-11 and MEB 3-1, Revision 2 criterion-for leakage cracks is based-on the same combined stress formula given in equation (1) above, except the threshold stress value on the right side of the equation is reduced by one-half as follows:

B, PD,/2t + B2 MDw/Z + B2 MoBE/Z + i MTH/Z > 0.4 (1.8 Sh + SA)

(2)

In equation 2, the term M/Z is also replaced by the resultant stress S term similar to the modification to equation 1. The modified equation is as follows:

B, PDo/2t + B2 SDW + B2 SOBF + i Srjj 0.4 (1.8 Sh + SA)

(2A)

Leakage cracks are to be postulated in locations where the combined stress exceeds the threshold value of 0.4 (i.

8 Sh+ SA).

4.4 Calculation of Stress Indices Calculated values for various pipe sizes and schedules associated with the piping in the stress tables are provided on Table - 1 in Attachment A. Stress Indices are calculated in accordance with ASME Section III, Subsection NB, Table NB-3681 (a)-] found in Reference 4, and SIFs are calculated in accordance with ASME Section I1I, Subsection NC, Figure NC-3673.2(b)-l.

The following equations are used to calculate the stress indices (B1 and B2) and SIF (i) for welding elbows and welding tees in accordance with ASME Section III, NC and NB rules (Reference 4).

Form 3.1-3 Rev. 2 Form 11-3 Rev. 2

CALCULATION SHEET Page:

10 of 17 Catc. No.: PBNP-994-21-05-PO5 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit I Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes

[]

No LI Date: 10/03/2008 6

Curved Pipe or Butt Welding Elbows (NB-3683.7):

B, = -0.1 + 0.4-h but not <0 nor >0.5 1.30 h(2 but not < 1.0 where:

R=

nominal bend radius of curved pipe or elbow, in r,,,

mean pipe radius, in, = (DQ - t)/2 t =

nominal wall thickness of pipe, in D,,

outside diameter of pipe, in h = flexibility characteristic and from Figure NC-3673.2(b)- I t-R 2

0.9 i=3 0

Butt Welding Tees (NB-3683.9):

B, = 0.5 (Table NB-368 1(a)-l) 2 132b = 0-4 Lý! )j 2

R)3 Trr where:

I=

mean radius of run pipe, in, = (Do - t)/2 Tr = nominal thickness of run pipe, in Do outside diameter of pipe, in B2b = B2 stress index for branch pipe B2r = B2 stress index for run pipe but not < 1.0 but not < 1.0 and friom Figure NC-3673.2(b)-I h

4.4Tr Rin 0.9 11(13 )

Stress Indices for straight pipe run are obtained from Table NB-3681(a)-i (Ref. 4), and they are:

B, =0.5, and B2 = 1.0.

Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

Automated Engineering CALCULATION SHEET Page:

11 of 17 Services CopCaic.

No.: PBNP-994-21-05-P05 SevcsCorp Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit I Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes

[Z No El Date: 10/03/2008

5.0 REFERENCES

1. USAS B3 I. 1O - 1967, Power Piping Code.
2.

PBNP FSAR (08/04), Appendix A.2.

3. Generic Letter 87 Relaxation in Arbitrary Intermediate Pipe Rupture Requirements, June 19, 1987.
4. ASME Section I[I, 1986 Editions.
5. AEC-DOLs Letter to WPS of December 15, -1972 (Mr. Giambusso to Mr. James).
6. PBNP Pipe Stress Analysis Reports.

a)

PBNP Accession No. WE100 109, Piping System-Qualification-Report for Main Steam to Auxiliary Feedwater Pump IP-29, Unit 1, Rev. 0 including Addenda A & B.

b)

PBNP Accession No. WBE1001 10, Piping System Qualification Report for Main Steam Piping to Anchor EB-8-A 120 (Outside Containment), Unit 1, Rev. 0.

c)

PBNP Accession No. WIE100 111, Piping System Qualification Report for Main Steam Piping to Anchor EB-8-A 119 (Outside Containment), Unit 1, Rev. 0.

7.

DG-M09, Rev. 2, Design Requirements for Piping Stress Analysis.

8. Drawing M-201 Sh. 1, Revision 54, Piping Subsystems P&ID - Main & Reheat Steam System.
9. NRC Information Notice 2000-20, Potential Loss of Redundant Safety Related Equipment Because of the Lack of High Energy Line Break Barriers, 12/11/2000.
10. ASME Section III B&PV Code, Subsection NC and ND, 1977 Edition up to and including 1978 Winter Addenda.
11. Isometric Drawing P-106 Revision 8, "Main Steam to Aux. Feedwater Pump 1-P-29, 3"-EB-8".
12. Isometric Drawing P-172 Revision 9, "Auxiliary Steam Supply to Evaporator".
13. Calculation No. PBNP-994-21-02, HELB Reconstitution Program-Task 2, High Energy System Selection, Rev, 0.

Form 3.1-3 Rev. 2

Auto mated Engineering Services Corp Page:

12 of 17 Calc. No.: PBNP-994-21-05-POS Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Cale.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes IN No D

I Date: 10/03/2008 6.0 GL 87-11 BREAK AND LEAK LOCATION CALCULATIONS As discussed in Section 4.0, the threshold stress limits used by GL 87-11 are determined in accordance with the requirements of ASME Section III Code, for Class 2 and 3 piping. This Section provides additional information on the GL 87-11 method to determine postulated break and crack locations.

6.1 Application of GL 87-11 Criteria The requirements of GL 87-11 (Reference 3) are applied to the Steam Supply piping from the branch connection points at the 30" Main Steam headers to AFW Pump lP-29. Part of the requirements to implementing GL 87-11 is that the stress evaluation is to be in accordance with ASME Section 111, 1986 edition. Table I in Attachment A calculates the B, and B2 stress-indices-and SIF (i) for the steam-supply piping. These indices are calculated in accordance with Paragraphs NB-3683.7, NB-3683.8, NB-3683.9, Table NB-368 1(a)-1 and Figure NC-3673.2(b)-I.

6.2 Manipulation of Stress Equations in EXCEL Spreadsheets A spreadsheet or stress table for each line segment of concern was developed taking piping stress data from References 6 computer analyses. Appropriate stress indices were included for each analytical point under consideration. This information was then used to calculate the combined stress value for comparison to threshold values established per equations (1A) and (2A) that were defined in section 4.0.

A detailed explanation of the different columns used in the stress tables (spreadsheets) is as follows:

Column Description Remarks A & X Node or Analysis Point Number B

Outside Diameter of pipe segment, in Taken from Ref. 6.

C Nominal Thickness of pipe segment, in D

Internal pressure = design pressure, psi E

Resultant Dead Weight Stress, SDw, Psi Calculated in Resultant F

Resultant Thermal Expansion Stress, STri, Psi Stress Table based on 0

Resultant Seismic Stress (Due to X & Y earthquake), SOI3Jxy, Psi moments friom computer H

Resultant Seismic Stress (Due to Y & Z earthquake), SOBEYZ, Psi output of Ref. 6 J

Stress Intensification Factor (SIF), (i)

K B I stress index Calculated as shown in L

B2 stress index Section 4.4 and Table - I M

Longitudinal Pressure Stress, psi. This is the first component in

= B1*P*Do/2*t equations (1) and (2) shown in sections 4.1 and 4.3 N

Deadweight stress, psi. This is the second component in equations (1A) and (2A) shown in sections 4.1 and 4.3

= B2*(SDw)

Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

CALCULATION SHEET Page:

13 of 17 Calc. No.: PBNP-994-21-05-PO5 1-Client:

Florida Power & Light Station: Point Beach Nuclear Plant - Unit 1 Revision: 0

-t Prepared By: Chris Kandalepas Caic.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes Y

No F]

Date: 10/03/2008 Column Description Remarks P

Thermal expansion stress, psi. This is the fourth component in

= i *(ST1) equations (1A) and (2A) shown in sections 4.1 and 4.3 Q

Operating basis earthquake (OBE) stress, psi. This is the third

= B 2* [SOBE (max of SooExy component in equations (1A) and (2A) shown in sections 4.1 or SOBEYZ)]

and 4.3 R

Combined Stress, psi

= Sum of columns M, N, P, and Q S

Threshold Limit for Leakage Crack Postulation

= 0.4 (1.8 Sh + SA)

T Threshold Limit for Large Break Postulation

= 0.8 (1.8 Sh + SA)

V Ratio of combined stress /threshold crack limit Crack postulated if> 1 W

Ratio of combined stress / threshold break limit Break postulated if> I The Steam Supply piping material is A 106 Gr. B (Reference 6). At temperatures < 650 'F, the allowable hot condition stress, Sh and allowable stress range, SA, per Reference 4 are as follows:

S,= S1 = 15000 psi SA 2 2 5 0 0 psi, from Reference 4, Table 1.7.1 where SA = f (1.258 + 0.25 St,) and f = 1.0, per NC-3611.2(e)

Threshold Limit for Intermediate Large Circumferential or Longitudinal Breaks: 0.8(1.8*Sh, + SA) = 39600 psi Threshold Limit for Leakage Cracks: 0.4(1. 8*Sh + SA) = 19800 psi Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

Automated Engineering CALCULATION SHEET Services Corp Page:

14 of 17 Cale. No.: PBNP-994-21-05-P05 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes 0I No E]

Date: 10/03/2008 6.3 Sample Calculations Sample of Resultant Stress Calculations (Table - 2, Attachment A2):

For Example Nodes 25 and 35 (Ref. 6a)

D:=3.5ain t:r=O.216in D, := D - 2.t D, = 3.068in SIF:=1.777 B1 :=0.044 B2 :=2.566 Section Modulus 7

.(D4-DI4) 32.D S = 1.72in3 DW TH OBE(X+Y) OBE(Y+Z)

(5 1205 221 143).

7 996 190 136)

DW TH OBE(X+Y) OBE(Y+Z)

MZ:=(75 1299 378 191).ft.lbf (81 907 373 165)

OW TH OBE(X+Y) OBE(Y+Z)

M 105 308 32')

(4 121 318 32)

VFMx2 + MY2 + MZ2 S

DW TH OBE(X+Y) OBE(Y+Z)

C524 12354 3726 1676) 567 9414 3659 1505)

Resultant Stress 25 35 Form 3.1-3 Rev. 2 Form 3.1-3

- -Rev. 2

Automated Engineering CALCULATION SHEET Services Corp Page:

15 of 17 Cale. No.: PBNP-994-21-05-P05 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes

[]

No El Date: 10/03/2008 Sample of Stress Table Calculation (Table -3, Attachment A3):

For exam COLUMN A

B:

C:

D:

E:

F:

G&H:

J:

K:

L:

pie row of Node Point 25 is considered Choose Node 25 from the Stress Table for Steam Supply to AFW Pump 1 P-29 Outside Diamter of pipe, Do := 3.50 in Pipe Thickness, t, := 0.216in Internal pressure, P := 1145psi Resultant Deadweight stress, SDw:= 524-psi Resultant Thermal Expansion stress, ST1t:= 12354psi Resultant Seismic (max OBE) stress, SOBE := ma43726, 1676).psi Stress intensification factor, i:= 1.777 Stress index, B, := 0.044 Stress index, B, =2.566 M:

Longitudinal pressure stress, N:

Deadweight stress, P:

Thermal Expansion stress, B 1P.Do Col M := -P Co 2.t, CoI_N := B2. Sw Co I_M= 408psi IN= 1345psi CoIP := i-STH Col_Q:= B2.SOBE 0:

OBE stress, ColP = 21953psi ColIQ = 9561psi CoI_R = 33267psi Combined stress, Col_R := ColM + ColN + ColP + CoLIQ Limit for Crack, Col_S ;= 1900psi Limit for Break, Col_T := 39600psi V:

Ratio of combined stress to limit for crack, W;

Ratio of combined stress to limit for break, Cl Col R ColV:=

o_

Col_S Col R CoIW := co-R ColCT Col_V = 1.68 ColW = 0.84 Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

Automated SevcsCorp I Page:

16 of 17 Cale. No.: PBNP-994-21-05-P05 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit I Prepared By: Chris Kandalepas Calc.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes

[

No El Date: 10/03/2008 7.0 RESULTS & CONCLUSIONS Results The 3" Steam Supply lines from the 30" Main Steam headers (Node Points 16 & GI 5) to AFW Pump IP-29 have been evaluated for break and crack locations following the requirements and criteria of Generic Letter GL 87-11.

Large Breaks Terminal end circumferential breaks are to be postulated at the terminal ends of the steam supply lines at the branch connection (Node Points 16 & G 15) to the Main Steam headers in the Auxiliary Building, at intermediate anchors EB-8-119-& EB-8-120, and at the inlet side of Motor Operated Valves IMOV-2019 and IMOV-2020 upstream of the AFW Pump. Locations where large breaks are required to be postulated are summarized in Table 7.1 below.

As seen fiom the stress table in Attachment A, all steam supply piping combined stresses are well below the Intermediate Large Break Threshold Limit. Therefore, no intermediate large breaks need be postulated for the 3" Steam Supply Lines for the MS headers to the AFW Pump.

Table 7.1 - Postulated Large Breaks at Terminal Ends and Intermediate Locations Break Location Node Point Notes 3" Steam Supply lines from MS Header Branch 16, GI 5 Terminal End Connections to AFW Pump 3" Steam Supply line at anchor EB-8-A 119 1055 Terminal End 3" Steam Supply line at anchor EB-8-A120 5

Terminal End 3" Steam Supply at inlet of 1MOV 2019 590 Terminal End 3" Steam Supply at inlet of IMOV 2020 385 Terminal End 3" Steam supply line at anchor SA-3-601-$29 1355 Terminal End Form 3.1-3 Rev. 2 Form 3.1-3 Rev. 2

AEngineering Servics tod e:

17 of 17 Cale. No.: PBNP-994-21-05-PO5 Client:

Florida Power & Light Revision: 0 Station: Point Beach Nuclear Plant - Unit 1 Prepared By: Chris Kandalepas Cale.

Title:

Steam Supply Piping to AFW Pump GL 87-11 Break Location Determination Reviewed By: Dan Quijano Safety Related Yes NI No EI Date: 10/03/2008 Leakage Cracks (Small Breaks)

Leakage cracks need to be postulated at locations where the combined stress exceeds the threshold limits as shown in the stress table (Attachment A). Locations where leakage cracks are required to be postulated are surnimrized in the Table 7.2 below.

Table 7.2 - Leakage Crack (Small Break) Locations for Steam Supply Lines Crack Location Node Point Notes Both riser elbows downstream of anchor EB-8-120 25,35,70,80 3" Pipe at support EB-8-R383 315 Elbow downstream-of support EB-8-R383-335 3" Tee to relief valve IMS-251 375 3" Pipe at support EB-8-R380 380 Inlet of valve I MS-251 1065 2 -d Elbow downstream of 1MS-251 1100,1110 3rd Elbow downstream of IMS-251 1120,1130 Conclusions An evaluation of the Steam Supply lines from the 30" MS headers to AFW Pump using the GL 87-11 and its associated USNRC Branch Technical Position MEB 3. 1, Rev. 2 (Reference 3) is described in this calculation.

The calculation shows that:

Intermediate stress related and arbitrary large breaks need not be postulated anywhere along the entire Steam Supply lines to AFW Pump.

Circumferential large breaks are recquired to be postulated at the terminal ends as shown in Table 7.1.

Leakage cracks (break size = Y2 times the pipe wall thickness x 1/2/2 the pipe internal diameter) are required to be postulated at the locations summarized in Table 7.2.

This calculation does not address the postulation of a single crack, exclusive of stress, at the most severe location with respect to essential equipment (IE Notice 2000-20, Reference 10), nor does this calculation address the consequences or evaluate the impacts of breaks or cracks that are required to be postulated based on this criteria.

Form 3.1-3 Rev. 2

Cale. No. PBNP-994-21-05-P05, Rev. 0 Attachment A, Page Al of A3 Prepared by: Chris Kandalepas Checked by: Dan Quijano Date: 811812008 TABLE - 1: STRESS INDICES (FOR USE IN STRESS TABLES)

Outside Nominal Mean Radius Crved pipe or Butt Weldin Elbows WeldinI Tees Nominal Diameter Pipe NmnlMa aisCre ieo utWligEbw Pipe Size of Pipe Schedule Thickness of pipe ( r,)

Bend Flex. Char.

SIF (i)

Index B, Index B, Flex.

SIF (I)

Index B2 Note 1

( Do )

of pipe (t)

Note I Radius (R)

(h)

Note I Note I Char.(h)

Note 2 Note I Note I Note 1

Note I Tee-Run Tee-Br Note_

____1___

3 3.50 40 0.216 1.6420 4.5 0.3605 1.7768 0.0442 2.5664 0.5788 1.2958 1.933 1.547 3

3.50 40 0.216 1.6420 3.0 0.2403 2.3282 0.0000 3.3630 0.5788 1.2958 1.933 1.547 Notes:

1) For applicable equations for calculating rm, Rm, r, h, i, B1 and B2, see Section 4.4 of main calculation.
2) Bend Radius is long radius elbows (1.5 x diameter) or special radius given in pipe stress analysis input (Ref. 6).

Calc. No. PBNP-994-21-05-P05, Rev. 0 Attachment A, Page A2 of A3 Prepared by: Chris Kandalsoas Checked by: DanQuano Date: 8118/2008 TABLE - 2 Resultant Stress Calculation Table for Steam Supply Piping from Anchors EB-8-Al 20 & -A119 to AFW Pump 1P-29 U.0~~r~eRos n Outside Pipe Section SIl die.

thickness Modulu CIa.

NODES D (in)

I t (in)

I S ln)

I I

8 ftolbe I

ft-lbs It-lbs I

ft-Ibm t-lbs I

ft-lbe I

Resultant Stress Calculation Table for Steam Supply Piping from 30" MS Header to Anchor EB-8-A120 (eased on analysis results from Accession No. WE.-00110 Rev. 0, Dated 10-30-96) 90 3.0 0.216 1.72 1.08 0

10 4

55 244 220 77

" 62 01 01 71 07 72 390 2926 070 075 210 3.0 8

0.210 1 1.72 1.7§70 1

0 1

1 5

300 3

0,11 4 20 00 3 05 1

12 0 1 005 8

3 130 1

14 1

4404 112 0

Resultant Stress Calculation Table for Steam Supply Piping from 30" MS Header to Anchor EB-8-Al 9 (Based on analysis results from AccessIon No. WE-100lt1 Rev. 0, Dated 10-30-95)

I 95 I

3,5 I

0,210 I

1.72 I

1.880 I

126 I

0 1

I 302 I

184 I

60 I

110 I

81 I

73 I

1508 I

al I

028 I

2702 I

1030 I

133d I

222 3.6 0.2 6

.7

.8110 47 1

3 1

1 339 1

294 1

67 1

4`1 1

39 1

189 1

71 1

44 1

359 1

3513 1

M 1

1435 1

Calc. No. PBNP-a94-21-05.P05, Rev. 0 Attachment A, Page A3 of A3 Prepared by: Chris Kandaleons Checked by: Den Quflono Date: 8/18/2008 TABLE - 3 Stress Table for Steam Supply Piping from Anchors EB-8-A120 & -Al19 to AFW Pump IP-29 aced on anaile reuIts from Accession No. WE-00109 Rev. 0. Dated 9-30-98a E

Ji L

I M

I N

P 1

R -

1 V

I W

X 1-es r-'

NODES Outaide Pipe Internal Dead Thermal MaxX 4 Y dia.

thicknese Pressura Weight h

Epon aelemic Do (in) tI. (in)

P (psi) pcl psi psi Seismic psi SIF Calt.

INDEX el INDEX B2 Long.

Pr.

Stress pSI Dead Weight Stress psi Thermal Expansion Stress psi OBE Stress psi

Comb, Stress psi Limit for Crack Limit for Break Ratio Com*kimit Crock Limit Ratio Break Limit NODES Stress Table for Steam Supply Piping from 30" MS Header to Anchor EB-8-Al 20 (Based on analysis results from Accession No. WE-1001 10 Rev. 0, Dated 10-30-95)

S 95 I

2.0 I

0U.

1145 1

60 I

0.500 I

1.000 i

4638 i

390 I

5501 I

975 I

11504 I

19800 I

39600 I

0.5810 I

0.2905 I

95 1

I 215 I

3.5 I

0.

1145 4494 77 I

0.044 I

2.568 i

408 I

e79 I

7900 I

3143 I

11916 I

19800 i

39600 I

0.6018 I

0.3009 I

216 I

Stress Table for Steam Supply Piping from 30" MS Header to Anchor EB-8-Al 19 (Based on analyies results from Accession No. WE-.tlOSI Rev. 0, Dated 10-30-95)

I 95 I

3.

i 0.210 I

1145 I

928 I

2702 i

1038 I

1330 I

1.880 9800 0.6051 I

0.3026 I

95 I

222 I

3.5 I

r.216 i

1145 I

359 I

3513 i

722 I

1438 i

1MCI s0i2 Unn0 n 6AF 658 I

n2af3 9792

I

-)

'S 8

1 7

1 6

5 1

4 H

Y X (SOUTH)

H G

G E

C 3185 r

(St/S

ý00 I

~0

-0

-U -o AIL

'4, 40

4::

0 c

B ACCESSION NOS,,

WE-100109 (SUBSYSTEM 3'-EB-8)

'E7"loollo (SUBSYSTEM 3'-EB-8)

WiE'-l00111 (SUBSYSTEM 3'-EB-B)

LEGEND 0

DENOTES POSTULATED PIPE LINE BREAK,

(

DENOTES BREAK NODE NUMBER, B

POINT BEACH NUCLEAR PLANT A

)

k AUTOMATED

/

ENGINEERING AU.

SERVICES CORP.

40 SHUWN BLVD.

SUI 220, INAPERIAL IL 60503 TMAIN STEAM SYSTEM, UNIT I TO AUX. FEED WATER PUMP IP-29

& RS-SA-09, RS-1 POSTULATED LINEBREAKS; ISOMETRIC oftNN JDAIL I7-028I sc.&w NONE WO.

I RL.A I,.,...

T(-M~-1TTr~ 2 I I CHKO lApm

ý I

SK-MS-FIG 21 1

I NO.

I I

%I*

I I

'.4 C

I I

TECHNICAL POSITION PAPER FOR ESTABLISHING HELB BREAK & LEAKAGE CRACK LOCATION SELECTION CRITERIA Rev. 0, December 4, 2006 Rev. 1, August 7, 2008 CO& o o. PBtj P-7? q -z 2.-o05-P0 eo 1.0 Introduction AVao-6A, Q Ro-*e CG-Point Beach currently utilizes different Pipe Break Outside Contaimnent (PBOC) location selection criteria in the HELB Program and EQ Program in regards to environmental parameters. The HELB Reconstitution Program (Program), as currently envisioned, will prepare documented calculations for the pressure, temperature and humidity time histories for a variety of HELB scenarios. Since the Program will reconstitute the design basis for PBOC and the resultant event enviromnent outside Contaimnent, these environmnental parameters would be equally applicable and used as the input to the EQ Program. With this approach PBNP will have a single unified HELB approach to address impacts on EQ and structural effects including compartment pressures and temperatures, jet impingement, pipe whip among others Before proceeding with the Program, a major consideration needs to be addressed and agreed upon by PBNP. This involves the adoption of Generic Letter 87-11 and its associated NRC Mechanical Engineering Branch Technical Position, MEB 3-1, Revision 2.- Considerable discussions have taken place in the past on the extent and use of GL 87-11 and its associated MEB 3-1, Rev. 2. Currently, PBNP EQ Program uses a variation of the MEB 3-1 document involving the use of the combined stress threshold for break location of 0.8(1.2 Sh +SA) to establish the EQ parameters (Reference 4, 5). It is noted that Revision I of MEB 3-1 stipulates the above break location threshold limit.

The PBNP FSAR Appendix A.2 (Reference 2) states "Break locations are selected in accordance with Reference 1. Consideration of arbitrary intermediate pipe ruptures is no longer required per NRC Generic Letter 87-11." The Reference 1 stated in the foregoing quotation is the Giambusso Letter of December 19, 1972. The Giambusso criteria included the threshold limit of 0.8(Sh+SA) and other requirements.

PBNP HELB DBD T-47 (Reference 6) provides a detailed discussion of the background history for the break location criteria. Without repeating these details, it is appropriate to state that the HELB location criteria have evolved over the years and there is a realization that these sets of criteria are "non-mechanistic" in nature. In other words, even though the pipe is designed to all design and analysis rules, additional precautions were imposed to provide added assurance for designing the plant SSCs against postulated pipe breaks. To provide a basis for establishing break locations, the AEC and NRC staff promulgated rules that tied these location selections to the stresses in the piping system. As the ASME Section III Piping Code equations (specifically Equations 9 and 10) (Reference 10) evolved so has the break location stress threshold limits. These changes in the break location criteria have led to the numerous discussions cited in the HELB DBD and the differences in the criteria used in the EQ Program and the FSAR citation.

Automated Engineering Services Corp

HELB BREAK & LEAKAGE CRACK LOCATION SELECTION CRITERIA Page 2 Caec.No.

u P-tq4q-21-05-PF$

o 0 2.0 Line Characterization Criteria and Break Selection Rules A

64.-aC, C j Pa P C2 It is noted that the criteria for the identification of HE lines outside containment (Design pressure>275 psi and service temperature > 2000F) and the fact that the current licensing bases of most vintage plants, including PBNP, do not recognize moderate energy lines, are separate and distinct criteria that should not be linked to the break location selection. In other words, changes to the HE break location selection criteria do not automatically require the re-visitation of the criteria for high and moderate energy line characterization. In fact, SRP 3.6.2, GL87-11 and MEB 3-1, Rev. 2 do not address the line characterization criteria, which is reviewed in SRP 3.6.1.

Since the line characterization for line breaks remains the same as stated in the FSAR, the section of MEB 3-1, Rev. 2 pertaining to moderate energy lines do not apply since the PBNP licensing basis does not characterize lines in this category. Similarly, the HE line definition for PBNP remains unchanged and only the lines that satisfy the "and" criteria and the "normally depressurized" rule need to be included in the HELB Program.

3.0 Proposed Unified PBOC Criteria for the PBNP HELB Reconstitution Program The following criteria for the Pipe Break Outside Containment (PBOC) are proposed for the HELB Reconstitution Program. Adoption and use of this-set of criteria will be across all PBNP Programs (EQ, HELB and others).

3.1 Retain the definition that all lines outside containment are designated as ASME Section III Class 2 and 3 as stated in the FSAR, Appendix A.2 and DG-M09 (Reference 9).

3.2 Retain the current definitions for HE lines, which does not require the characterization of lines for moderate energy.

3.3 Adopt the use of GL 87-11 and MEB 3-1, Rev. 2 rules for HE lines only including the rules for break and leakage crack location selection in their entirety. These rules utilize the 1986 ASME Code Equations 9 and 10 with the use of stress indices for dead weight and OBE resultant moments (B2 indices) and longitudinal pressure (BI indices) and stress intensification factors (i) for thermal expansion only. It is noted that the pipe stress analyses compute the resultant moments for the load cases. These resultant moments are independent of which Design Code is used. The code equations or in this case of establishing the break locations, the combined stress equation are computed from the stress resultants based on the specific formulations.

3.4 In addition, IN 2000-20 (Reference 7) clarifies the requirement of postulating a single open crack at the location most damaging to those essential structures and systems.

3.5 Types of breaks and cracks should be in accordance with the MEB 3-1 Section B.3.

3.6 When break criteria are based on stress calculation, it is recommended that breaks and cracks be based on the calculated stresses (Section B. 1.c(2)(b)(ii)) and not at each pipe fitting (Section B.1.c(2)(b)(i)) of MEB 3-1, Rev. 2. The stress requirement of Section B. 1.c(2)(b)(ii) should be based on the primary piping stress evaluation (Section NC/ND-

  • 4 i

AutonmatedEngineeringServie-es Corp

HELB BREAK & LEAKAGE CRACK LOCATION SELECTION CRITERIA Page 3 3653 of the ASME Code Section III) and local stresses at the integral welded attachtments(IWA), where applicable.

3.7 Where breaks locations are selected without the benefit of stress calculations, it is recommended that breaks be postulated at the piping welds to each fitting, valve, or welded attachment.

No. Pg-Y'?4-2 j-O5_-PO5 'ev.

(

4.0 Regulatory & Licensing Issues A.C-k*C-.

C) op E C3 Use of the MEB 3-1 equations to determine break and crack locations does not require prior NRC approval. The 50.59 process and changes to the FSAR would be required.

In order to be compatible with the activities previously performed for the EQ Program, a 50.59 Screening/Evaluation should be performed to accept the use of the of the proposed PBOC criteria for determining break and crack locations.

The proposed PBOC criteria has the potential of eliminating all intermediate large breaks and almost all small breaks (leakage cracks), except the one (single) mandatory crack at the most adverse location. The 50.59 Screening/Evaluation should also address the elimination of the longitudinal crack at the terminal ends required by the Giambusso letter, but eliminated by MEB 3-1.

5.0 Conclusion The above approach would result in a single unified set of HELB/EQ criteria that would be' applicable to all HELB related design parameters for the evaluation plant SSCs. The possible elimination of large breaks should result in lower environmental loads (compartment pressure and temperature) that would result in increasing design margins for the plant SSCs.

The HELB Reconstitution Program will utilize the Proposed PBOC Criteria and systematical address and documents the analysis and results in the various tasks outlined in the Task I Report (Reference 8) 6.0 References

1. "General Information Required for Consideration of the Effects of a Piping System Break Outside of Containment", AEC December 19, 1972 (Giambusso Letter)
2. PBNP FSAR Appendix A.2, High Energy Pipe Failure Outside Containment
3. USNRC Generic Letter GL 87-11, Relaxation in Arbitrary Intermediate Pipe Rupture Requirements and associated Revised MEB 3-1 of SRP 3.6.2
4. PBNP Calculation M-09334-357-HE.1
5. PBNP Calculation M-09334-357-HE.2, Rev. 01, High Energy Line Breaks in Selected Piping Systems
6. PBNP HELB DBD T-47, High Energy Line Break Design Basis Document, Rev. 0
7. USNRC Information Notice 2000-20, Potential Loss of Redundant Safety-Related Equipment Because of the Lack of High-Energy Line Break Barriers
8. AES Corp. PBNP HELB Reconstitution Program Task 1 Report, Rev. 0.
9. PBNP Design Guide DG-M09, Rev. 2, Design Requirements for Pipe Stress Analysis.
10. ASME B & PV Code Section III, Subsections NC and ND, 1986 Edition.

Automated Engineering Services Corp