BSEP 10-0061, Radiological Environmental Operating Report for 2009
| ML101380657 | |
| Person / Time | |
|---|---|
| Site: | Brunswick (DPR-062, DPR-071) |
| Issue date: | 05/13/2010 |
| From: | Mentel P Carolina Power & Light Co, Progress Energy Carolinas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| BSEP 10-0061 | |
| Download: ML101380657 (177) | |
Text
Progress Energy MAY 13 2010 Serial: BSEP 10-0061 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Brunswick Steam Electric Plant, Unit Nos. 1 and 2 Renewed Facility Operating License Nos. DPR-71 and DPR-62 Docket Nos. 50-325 and 50-324 Radiological Environmental Operating Report for 2009 Ladies and Gentlemen:
In accordance with Technical Specification (TS) 5.6.2 for the Brunswick Steam Electric Plant (BSEP), Unit Nos. 1 and 2, Carolina Power & Light Company, now doing business as Progress Energy Carolinas, Inc., is submitting the enclosed Radiological Environmental Operating Report for 2009.
No regulatory commitments are contained in this submittal. Please refer any questions regarding this submittal to Ms. Annette Pope, Supervisor - Licensing/Regulatory Programs, at (910) 457-2184.
Sincerely, Phyllis N. Mentel Manager - Support Services Brunswick Steam Electric Plant MAT/mat
Enclosure:
Radiological Environmental Operating Report for 2009 Progress Energy Carolinas, Inc.
Brunswick Nuclear Plant PO Box 10429 Southport, NC 28461
Document Control Desk BSEP 10-0061 / Page 2 cc:
U. S. Nuclear Regulatory Commission, Region II ATTN: Mr. Luis A. Reyes, Regional Administrator 245 Peachtree Center Avenue, NE Suite 1200 Atlanta, GA 30303-1257 U. S. Nuclear Regulatory Commission ATTN: Mr. Philip B. O'Bryan, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)
ATTN: Mrs. Farideh E. Saba (Mail Stop OWFN 8G9A) 11555 Rockville Pike Rockville, MD 20852-2738 Chair - North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-0510
Enclosure BSEP 10-0061 Radiological Environmental Operating Report for 2009
RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 2009 BRUNSWICK STEAM ELECTRIC PLANT 41 CAROLINA POWER & LIGHT COMPANY Now Doing Business as PROGRESS ENERGY CAROLINAS, INC.
SHEARON HARRIS ENERGY &
ENVIRONMENTAL CENTER CAROLINA POWER & LIGHT COMPANY NOW DOING BUSINESS AS PROGRESS ENERGY CAROLINAS, INC.
NEW HILL, NORTH CAROLINA RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT FOR BRUNSWICK STEAM ELECTRIC PLANT JANUARY 1 THROUGH DECEMBER 31, 2009
TABLE OF CONTENTS Title Page Table of Contents i
List of Figures ii List of Tables iii Executive Summary 1
Radiological Environmental Monitoring Program 3
Purpose and Requirements for the Radiological Monitoring Program 3
General Site Description 4
Radiological Monitoring Program Quality Assurance 5
Radiological Monitoring Program General Description 6
Summary of Radiological Monitoring Program 18 Interpretations and Conclusions 22 Missed Surveillances 27 Analytical Procedures 28 Land Use Census 36 Purpose of the Land Use Census 36 Methodology 37 2009 Land Use Census Results 37 Appendix GEL Laboratories, LLC's 2009 Interlaboratory Comparison Program Report 48 Data Reports i
LIST OF FIGURES Figure Page 1
Location of Brunswick Steam Electric Plant 4
2 Radiological Sampling Locations (Distant from Plant) 7 3
Radiological Sampling Locations (Nearest Plant) 8 4
BSEP Environmental Sampling Locations 9
5 BSEP Environmental Sampling Locations (Continued) 10 6
BSEP Environmental Sampling Locations (Continued) 11 7
BSEP Environmental Sampling Locations - Wells 12 8
BSEP Environmental Sampling Locations - Wells (Continued) 13 9
BSEP Environmental Sampling Locations - Wells (Continued) 14 10 Plot of Air Particulate Gross Beta Activity (Locations 200 and 204) 40 11 Plot of Air Particulate Gross Beta Activity (Locations 201 and 204) 41 12 Plot of Air Particulate Gross Beta Activity (Locations 202 and 204) 42 13 Plot of Air Particulate Gross Beta Activity (Locations 203 and 204) 43 14 Plot of Air Particulate Gross Beta Activity (Locations 205 and 204) 44 15 Plot of Air Particulate Gross Beta Activity (Locations 206 and 204) 45 16 Plot of Surface Water Tritium Activity (Locations 400 and 401) 46 17 Plot of TLD Averages for Inner and Outer Rings 47 ii
LIST OF TABLES Table Page 1
Media Used to Assess Exposure Pathways to Man 6
2 Radiological Monitoring Sampling Locations 15 3
Radiological Environmental Monitoring Program Data Summary 19 4
Gross Beta Air Particulate Activity Averages 25 5
Historical TLD Results (1972-2009) 26 6
Typical Lower Limits of Detection (a priori) Gamma Spectrometry 35 7
Land Use Census Comparisons (2008-2009) Nearest Pathway (miles) 38 8
Garden Census (2009) 39 iii
EXECUTIVE
SUMMARY
The Brunswick Steam Electric Plant (BSEP), Unit Nos. 1 and 2, is operated by Carolina Power &
Light Company, now doing business as Progress Energy Carolinas, Inc., under licenses granted by the Nuclear Regulatory Commission (NRC). BSEP Technical Specification 5.6.2 and the BSEP Offsite Dose Calculation Manual (ODCM) establish the requirements of the Radiological Environmental Monitoring Program (REMP). This report provides the results of the REMP from January 1, 2009 through December 31, 2009.
The REMP was established in 1973. Radiation and radioactivity in various environmental media have been monitored for more than 35 years, including monitoring in excess of a year prior to commencing operation. Monitoring is also provided for control locations which would not be impacted by operations of BSEP. Using the data from the control locations and the historical data collected prior to operation, analyses of data from locations which could potentially be impacted by the operations of BSEP were performed. Radiation levels show no measurable change from pre-operational radiation levels.
Monitoring results for environmental media are summarized as follows:
- Air-monitoring results are similar or less than the concentrations of radioactivity from pre-operation monitoring. These observations are also consistent with past operational data.
" Milk was unavailable due to no milk (milch) animals (goat or cow) currently identified within the environs of the plant; therefore, no exposure pathway exists.
- Terrestrial vegetation includes broadleaf vegetation from indicator and control locations.
Results indicate that Cobalt (Co)-60 and Cesium (Cs)- 137 activity was detected in indicator and control samples respectively, but no other gamma activity was detected in any sample except for K-40 (potassium-40) and other naturally occurring gamma activity.
- Aquatic organism monitoring includes fish (free swimmers and bottom feeders),
invertebrates (shellfish (SH)), and Benthic organisms (organisms that live on the bottom of the ocean (BO)). Results indicated no detectable plant - related activity.
" Surface water results indicate that some surface water samples detect the presence of tritium, which is attributed to plant operations. Refer to the Interpretations and Conclusions Section / Surface Water and Figure 16.
" Shoreline Sediment results indicate that some shoreline sediment indicator and background samples detected the presence of Cs-137 activity. No other gamma activity was detected in any sample (indicator or background) except for K-40 (potassium-40) and other naturally occurring gamma activity. Therefore, results indicated no detectable plant-related activity.
I
External radiation dose showed no measurable change from pre-operational data.
The continued operation of BSEP has not significantly contributed radiation or the presence of radioactivity in the environmental media monitored. The measured concentrations of radioactivity and radiation are well within applicable regulatory limits.
2
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM PURPOSE AND REQUIREMENTS FOR THE RADIOLOGICAL MONITORING PROGRAM Although the operation of a nuclear generating station results in the raising of background radiation only a small amount, it is important to measure these emissions of radioactivity and radiation to assess their impact on the surrounding populations. The purpose of the REMP is to measure accumulation of radioactivity in the environments, to determine whether this radioactivity is the result of operations of BSEP and to assess the potential dose to the off-site population based on the cumulative measurements of radioactivity of plant origin. Radiological monitoring programs provide an additional verification of the containment and radiological controls of nuclear generating stations.
The REMP was established in 1973 and continues to collect samples and evaluate them.
Requirements are established for the radiological monitoring program as follows:
> Technical Specifications
> Off-Site Dose Calculation Manual (ODCM)
> Various procedures Additional guidance regarding the radiological monitoring program may be found in the following:
> NRC Regulatory Guide 1.109, "Calculation of Annual-Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I"
> NRC Regulatory Guide 4.13, "Performance, Testing, and Procedural Specifications for Thermoluminescence Dosimetry: Environmental Applications"
> NRC Regulatory Guide 4.15, "Quality Assurance for Radiological Monitoring Programs (Normal Operations) - Effluent Streams and the Environment" 3
General Site Description BSEP consists of two boiling water reactors with a design rating of 2923 megawatts thermal. Commercial production was initiated by Unit 2 on November 3, 1975 and by Unit 1 on March 18, 1977. BSEP is located in Brunswick County, North Carolina. The site is along state route 87 approximately two and a half miles north of Southport and is displayed on the map of southeastern North Carolina (Figure 1).
The community of Boiling Spring Lakes is about three miles northwest of the site.
The towns of Caswell Beach and Oak Island are on a barrier island south of the
.plant. The site is also approximately 16 miles south of Wilmington, North Carolina.
SC~p.
F..
c..-h*U 17
.455Cn Figure 1: Location of Brunswick Steami Electric Plant The Cape Fear River is east of the plant, and cooling water is drawn from the river through a canal. The cooling water is discharged to the Atlantic Ocean through a canal, pumping station, and piping. The discharge point is south of the town of Caswell Beach.
The plant site varies in elevation from sea level to 30 feet above mean sea level (MSL). It is surrounded by extensive marshes. The lower Cape Fear River is an important nursery area for shellfish, and other marine species.
The local economy supports significant recreational, industrial, agricultural, and government contributions. There is well-developed recreational use of the barrier islands south and east of the site. Fishing and boating are popular activities. Commercial fishing is also an important industry in the community. Agriculture utilizes some of the landwithin50 miles of the site; such as small truck farms, cattle, poultry, and row crops including corn, soybeans and tobacco.
Industrial activity includes the Archer-Daniels-Midland Chemical (ADM) Company, a manufacturer of citric acid, located one and a half miles southeast of the plant. In conjunction with the citric acid plant is a small electrical generating station operated by Primary Energy. This coal-fired station is composed of two units rated at 55 MWe each.
4
Transportation is a significant industry in the local economy, with the Port of Wilmington north of the site. The shipping channel is just east of the site in the Cape Fear River. Also, the Sunny Point Military Ocean Terminal (MOT) is located approximately three miles north of the plant site on the Cape Fear River.
RADIOLOGICAL MONITORING PROGRAM QUALITY ASSURANCE A required component of the REMP is the Quality Assurance Program. The standards for the quality assurance program are established in NRC Regulatory Guide (R.G.) 4.15, "Quality Assurance for Radiological Monitoring Programs." According to R.G. 4.15, the purpose of the quality assurance program is "(1) to identify deficiencies in the sampling and measurement processes to those responsible for these operations so that corrective action can be taken, and (2)ý to obtain some measure of confidence in the results of the monitoring programs in order to assure the regulatory agencies and the public that the results are valid." This provides the opportunity to implement corrective actions that address possible deficiencies. Examples of the activities of the quality assurance program include:
> regular review of sample collection and records,
> regular review of laboratory procedures and methods,
> participation in the Eckert & Ziegler Analytics Environmental Cross-Check Program, which provides an independent assessment of the quality of laboratory results,
> BSEP participates in the Eckert & Ziegler Analytics Radiochemistry Cross-Check
- Program,
> GEL Laboratories, LLC (GEL) participates in an Intercomparison sample program from Eckert & Ziegler Analytics of Atlanta, Environmental Resource Associates of Arvada, Colorado; and the Mixed Analyte Performance Evaluation Program (MAPEP), and
> the use of known concentrations of radioactivity in test samples by the laboratory to ensure consistent quality results on an ongoing basis.
5
RADIOLOGICAL MONITORING PROGRAM GENERAL DESCRIPTION Although the contribution to background radiation is small, Carolina Power & Light Company, now doing business as Progress Energy Carolinas, Inc. has established this program to measure the exposure pathways to man. An exposure pathway describes the source of the radiological exposure. The primary forms of potential radiological emissions from the plant are airborne and liquid discharge. The following pathways are monitored: external dose, ingestion of radioactive materials, and the inhalation of radioactive material. Specific methods and different environmental media are required to assess each pathway. Table 1 provides a list of the media used to assess each of these pathways.
Table -1 Media Used to Assess Exposure Pathways to Man Pathway of Exposure to Man Media Sampled External Dose Thermoluminescent Dosimetry (TLD)
Shoreline Sediment Ingestion Broadleaf Vegetation Fish and Invertebrates Surface Water Inhalation Air Samples (Particulate and Radioiodine)
Sampling Locations Sampling locations are chosen based upon meteorological factors, preoperational monitoring, and results of the land use surveys. A number of locations are selected as controls. Control stations are selected because they are very unlikely to be affected by operation of the plant.
Sample locations may be seen in Figures 2 thru 9. A description of each sample location may be found in Table 2.
6
Radiological Sampling Locations 35 0 19M DoLarmi S~vA AL USA a *w ~
Figure 2: Radiological Sampling Locations (Distant from Plant)
Stations not illustrated:
204 (Sutton Plant in Wilmington) (Control Air Station), 206 (not ODCM required) 703, 704, 705 (Location not Specified in the Atlantic Ocean)(Control Fish Station) 802 (Location not specified) (Control Vegetation) 7
Radiological Sampling Locations Figure 3 (nearest Plant) is an expanded view of the previous figure (Figure 2 page 7).
8
Figure 4 BSEP Environmental Sampling Locations BSEP Environmental Sample Locations 9
Figure 5 BSEP Environmental Sampling Locations (continued) 10
Figure 6 BSEP Environmental Sampling Locations (continued)
SDSP: Storm Drain Stabilization Pond 11
Figure 7 BSEP Environmental Sampling Locations - Wells MdOw s a
ft A14 aW LOCM~
- f. IDRM W Aff 84M aV WC OWD1 AA J MMMAL WL - 39"WM N
-A I
"W=LJ AffM MAN MG RUE - OMMUIE AM - A"W AMM M
ALL
- EFlP HUL -
MEW SCALE V-I~ WAJA M ME~
E L) UP MA I6PIA
'W U-M Mopm EnOW Bn stmNM dw~Cf Figure 2-1 Mon~itorin~g W.I1 Netwe~k Storm, Drain, Stabilization Pond SS.,
1i2r Qrni~rac Tnr I
12
Figure 8 BSEP Environmental Sampling Locations - Wells sOUCE.
XGO Mc*(hn & ca'w.4 AMRn 15 2007.LG NOMES -~EA4EA
WOMEML Z~ ELEVAnanOA' AREASED ON NOW'29.
ENSXSTG EEDIA7E-lEU SCALE 1*= SW0 Progress Energy Brurdwick Nuclear Pla S"M~pal, N~C Fqiire 2-3 Intermediate Manibarirwq Wall Lo,"tion Map SSilar Services Inc.
0 250 500 1000 1500 13
Figure 9 BSEP Environmental Sampling Locations - Wells (continued) 01 ES,--1 0
7D I;4 0
RAoIcOL OG rCAL TEST W~ELL T a 1
1 T
r NOTE:
Well ESS-17 is located near the Biology Lab.
I 14
Table 2 Brunswick Steam Electric Plant Radiological Monitoring Sampling Locations Sample Type Location & Description Frequency Sample Size Analysis Air Cartridge 200--i.0 miles WSW Visitors Center Weekly (270 m3)
Iodine-131 (AC) 201--0.5 miles NE PMAC (Continuous 202--i.0 miles S Substation on Construction Rd.
Sampling) 203--2.0 miles SSW Southport substation 204--22.4 miles NNE Sutton Plant*
205--0.6 miles SSE Spoil Pond 206--11.3 miles NW from Plant @ Brunswick County Government Complex Air 200--i.0 miles WSW Visitors Center Weekly (270 m3)
Gross Beta Particulate 201--0.5 miles NE PMAC (Continuous (Weekly) 202--1.0 miles S Substation on Construction Rd.
Sapling) 203--2.0 miles SSW Southport substation Quarterly Composite 204--22.4 miles NNE Sutton Plant*
Gamma 205--0.6 miles SSE Spoil Pond (Quarterly) 206--11.3 miles NW from Plant @ Brunswick County Government Complex Fish (FI) and 700--5.5 miles SSW Atlantic Ocean @ discharge Semiannual 500 grams Gamma Inverbrates (free swimmers)
(In Season)
(wet)
(Edible 701--5.5 miles SSW Atlantic Ocean @ discharge portions)
(bottom feeders) 702--5.5 miles SSW Atlantic Ocean @ discharge (invertebrates) 703--Atlantic Ocean; location not specified*
(free swimmers) 704--Atlantic Ocean; location not specified*
(bottom feeders) 705--Atlantic Ocean; location not specified*
(invertebrates) 706--Nancy's Creek; location not specified (free Annual Gamma swimmers)
Tritium 707--Nancy's Creek; location not specified portions)
(bottom feeders) 708--Nancy's Creek; location not specified (invertebrates)
Broadleaf 800--0.7 miles NE intake canal Monthly 360 grams Gamma
()tation 801--0.8 miles SW discharge canal (As (wet)
Iodine-131 802-- 0.1 miles; location not specified*
available) 803--0.6 miles SSE Spoil Pond 804--0.7 miles S Leonard Street plant exit adjacent to RR tracks Shoreline 500--5.0 miles SSW discharge; beach near OD Semiannual 575 grams Gamma Sediment pumps (SS) 501--Nancy's Creek, Adjacent to WP-55, Near Annual Storm Drain Stabilization Pond Surface 400--0.6 miles NE Intake Canal*
Monthly 4 liters Gamma Water (SW) 01--4.9 miles SSW discharge canal @ OD Composite Tritium Pumps (Quarterly)
- Control Stations 15
Table 2 (Continued)
Brunswick Steam Electric Plant Radiological Monitoring Sampling Locations Sample Type Location & Description Frequency Sample Size Analysis Surface 494--Nancy's.Creek-WP-106 Grab Sample, N/A Tritium Water (SW) 495--Nancy's Creek - WP-52 Weekly (Weekly)
(Continues)
Monthly Gamma 96--Nancy's Creek - WP-53 Mo(Monthly) 497--Nancy's Creek - WP-55 498--Nancy Creek - WP-57 499--Cape Fear River - WP-61" Groundwater (GW) 402--Monitoring Well ESS-2C, 0.17 miles W 403--Monitoring Well ESS-16, 0.16 miles W 404--Monitoring Well ESS-IB, 0.17 miles SW 405--Monitoring Well ESS-2B, 0.17 miles W 406--Monitoring Well ESS-3B, 0.08 miles N 407--Monitoring Well ESS-13B, 0.06 miles ENE 408--Monitoring Well ESS-13C, 0.06 miles ENE 409--Monitoring Well ESS-17A, 0.65 miles NE 410--Monitoring Well ESS-17B, 0.65 miles NE 411--Monitoring Well ESS-17C, 0.65 miles NE 412--Monitoring Well ESS-18B, Near SDSP 413--Monitoring Well ESS-18C, Near SDSP 414--Monitoring Well ESS-19B, Near SDSP 415--Monitoring Well ESS-19C, Near SDSP 416--Monitoring Well ESS-20B, Near SDSP 417--Monitoring Well ESS-20C, Near SDSP 418--Monitoring Well ESS-211B, Near SDSP 419--Monitoring Well ESS-2 1 C, Near SDSP 420--Monitoring Well ESS-22B, Near SDSP 421--Monitoring Well ESS-22C, Near SDSP 422--Monitoring Well ESS-23C, Near SDSP 23--Monitoring Well ESS-24A, Near SDSP 424--Monitoring Well ESS-24B, Near SDSP 425--Monitoring Well ESS-24C, Near SDSP 426--Monitoring Well ESS-25B, Near SDSP 427--Monitoring Well ESS-25C, Near SDSP 28--Monitoring Well ESS-26C, Near SDSP 429--Monitoring Well ESS-27A, Near SDSP 430--Monitoring Well ESS-27C, Near SDSP 4331 --Monitoring Well ESS-30C, Near SDSP 432--Monitoring Well ESS-3 1 C, Near SDSP 133--Monitoring Well MWm2, 0.02 miles S 434--Monitoring Well MW-3, 0.03 miles S 435--Monitoring Well ESS-Nancy Creek-1, (NC-1) 436--Monitoring Well ESS-Nancy Creek-2, (NC-2) 437--Monitoring Well ESS-Nancy Creek-3, (NC-3) 438--Monitoring Well ESS-Nancy Creek-4, (NC-4) 439--Monitoring Well ESS-Nancy Creek-5, (NC-5) 440--Monitoring Well ESS-Gum Log Branch-l, (GLB-1) 447--Monitoring Well ESS-28C, Near SDSP Grab Sample, Quarterly, Semiannual N/A Tritium (Quarterly)
Gamma (Semiannual)
- . Control Stations 16
Table 2 (Continued)
Brunswick Steam Electric Plant Radiological Monitoring Sampling Locations Sample Type Location & Description IFrequencyI Sample Sz I Analysis Thermoluminescent Dosimetry (TLD)
(Direct Radiation) 1 1.1milesE 2
0.9 miles ESE 3
0.9 miles SE 4
1.1 miles SSE 5
1.1milesS 6
1.1 miles SSW 7
1.1 miles SW 8
1.2milesW 9
1.0 miles WNW 10 0.8 miles NW 11 0.9 miles NNW 12 1.1 milesN 13 1.2 miles NNE 14 0.5 miles NE 15 0.9 miles ENE 16 1.0 miles WSW 17 1.4 miles ESE 18 1.7 miles SE 20 2.1 miles S 21 2.9 miles SSW 22 5.3 miles SW 23 4.6 miles WSW 24 3.0 miles W 25 8.6 miles WNW 26 5.9 miles NW 27 5.1 miles NNW 28 4.2 miles NW 29 2.6 miles SSW 30 2.0 miles NE 31 2.5 miles ENE 32 5.8 miles ENE 33 4.1 miles E 34 5.4 miles E 35 7.3 miles SSE 36 8.9 miles NE 37 5.5 miles NW 38 11.0 miles W 39 5.3 miles SW 40 6.9 miles WSW 75 4.7 miles S 76 4.8 miles SSW 77 5.4 miles S 78 9.9 miles NNE 79 9.5 miles N 81 9.9 miles WNW*
Quarterly Not Applicable TLD Reading (Gamma Dose)
- Control Station
17
SUMMARY
OF RADIOLOGICAL MONITORING PROGRAM This report presents the results of the Radiological Environmental Monitoring Program conducted during 2009 for BSEP. The program was conducted in accordance with the ODCM, and applicable procedures.
The 2009 Annual Radiological Environmental Operating Report (REOR) has been prepared and submitted in accordance with Technical Specification 5.6.2 and ODCM 7.4.1. The report applies to both BSEP Unit Nos. 1 and 2 (License Nos. DPR-71 and DPR-62, respectively).
A total of 1921 sample measurements were performed on 1818 collected samples from indicator and control locations from eight environmental media types during the year. No detectable radioactivity (or radioactivity that differed significantly from the-corresponding control) was observed in any of the 1700 measurements performed on the 1621 indicator location samples in 2009, except for Co-60 in broadleaf vegetation samples, and tritium in ground water and surface water samples. No gamma activity was detected in any of the ground water or surface water samples, except for K-40 and other naturally occurring gamma activity. All samples analyzed met the Lower Limit of Detection (LLD) requirements as established by ODCM Table 7.3.15-3.
The radiological environmental data indicates that BSEP operations in 2009 had no significant impact on the environment or public health and safety. No measurable radiation exposure is attributed to any off-site member of the public due to the operations of BSEP.
A statistical summary of all the data gathered in 2009 has been compiled in Table 3.
Comparison of the current data with preoperational (1973, 1974) information (Tables 4 and 5) indicates that air particulate filter gross beta activity and ambient gamma radiation levels were lower for gross beta and about the same for gamma in 2009.
18
TABLE 3 BRUNSWICK STEAM ELECTRIC PLANT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DATA
SUMMARY
Brunswick Steam Electric Plant Brunswick County, North Carolina Docket Numbers 324 and 325 Calendar Year 2009 I
- rr I
I*
Location w/Highest AnnualMean Medium or Pathway
-.Type and Lower Limit All Indicator Name, Distance, Mean Control Locations Samdple~dorMeasured Total No; of of Detection Locationst2 and Direction Range)
Mean (Unit of Measurement)
Measurements (LLD))-
Mean Ranget2
-- Performed.
-Range Air Cartridge 1-131 5.0E-2 All less than LLD All less than LLD (pCi/m3) 350 Air Particulate Gross Beta(8 )
5.OE-3 1.89E-2 (298/298)(7)
Brunswick County 1.95E-2 (38/38) 7) 1.83E-2 (52/52) (7)
(pCi/m3) 350 8.33E 3.25E-2 Government Complex 1.01E 2.90E-2 7.76E 2.69E-2 11.3 miles NW Gamma(4) (8)
See Table 6 All less than LLD All less than LLD 27 Broadleaf Vegetation Gammat 4) 3.9E-2 3.79E-2 (3/54) (7)
Discharge Canal 4.94E-2 (2/13) (
All less than LLD (pCi/g, wet) 69(3) 2.3 1E 7.57E-2 0.8 miles SW 2.3 1E 7.57E-2 Co-60 Cs-137 3.6E-2 All less than LLD 1.69E-2 (2/15)(7) 1.60E 1.78E-2 Fish and Invertebrates Tritium 1.00E+lt9 )
All less than LLD No control (pCi/g, wet) 3 Gamma(4 )
See Table. 6 All less than LLD All less than LLD 15 Sediments--Shoreline Gamma(4 )
4.5E-2 1 :65E-1 (3/5) (7)
Nancy's Creek 1.65E-1 (3/3) (7)
No control(10 )
(pCi/g, dry) 5 1.44E 2.03E-1 adjacent to WP-55 1.44E 2.03E-1 Cs-137 near SDSP Hard-to-detects See Table 6 All less than LLD No control (Fe-55, Sr-89/90) 19
TABLE 3 (cont.)
BRUNSWICK STEAM ELECTRIC PLANT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DATA
SUMMARY
Brunswick Steam Electric Plant Brunswick County, North Carolina Docket Numbers 324 and 325 Calendar Year 2009
.Location w/fHighest Annual Mean
-Medium or Pathway Lower Limit All Indicator Name, Distance, Mean Control Locations
- Sampled or Measured Total No. of of Detection Locations(2 )
and Direction Ranget 2 Mean
- (Unit of Measurement):
Measurenmefts-(LLD)(')
Mean Ranget 2
-Performed" Range.
Surface Water Tritium 2.50E+2(6) 4.07E+2 (4 8/ 2 7 2 )(7)
Discharge Canal 5.75E+2 (1/12)f7)
All less than LLD (pCi/1) 336 2.45E+2 - 1.10E+3
@ OD Pumps Single value 4.9 miles SSW Gamma(4)
See Table 6 All less than LLD All less than LLD 97 Ground Water Tritium 2.50E+2(6) 1.29E+5 (185/403)(7)
Well ESS-22C 6.48E+5 (10/10)(7)
No control (pCi/1) 403 2.39E+2 - 1.04E+6 Near SDSP 2.72E+5 - 8.93E+5 Gamma(4)
See Table 6 All less than LLD No control 84 TLD TLD Readout 1.00E+1 (175/176) (7) 1.20E+l (4/4) (7) 1.06E+l (4/4)(7)
(mR per quarter)t 5 )
179(')
7.10E+0 -1.37E+l 6.9 miles WSW 1.12E+l - 1.29E+l 9.50E+O - 1.20E+l 20
FOOTNOTES TO TABLE 3
- 1. LLD is calculated based on 4.66 standard deviations above background using typical sample sizes and counting times. Due to counting statistics and varying volumes, occasionally lower LLDs are achieved. See Table 6.
- 2.
Mean and range are based on detectable measurements only. The fractions of detectable measurements at specific locations are indicated in parentheses.
- 3.
Missing samples are discussed in Missed Surveillances.
- 4. Summary of gamma analysis results in this report does not include the following naturally occurring isotopes since most environmental samples contained some or all of these: Be-7, K-40, T1-208, Pb-212, Bi-214, Pb-214, and Ra-226.
- 5.
TLD dose is reported in milliroentgen (mR) per 90-day period (quarter) beginning in 1995.
This is the exposure standard used to compare data to the NRC.
- 6. The tritium LLD was approximately 2.50E+2 pCi/L. The LLD was lowered at the request of Carolina Power & Light Company, now doing business as Progress Energy Carolinas, Inc. in order to maintain comparable LLD values with the North Carolina Division of Radiation Protection (NCDRP) laboratory.
- 7. The numbers in parentheses [e.g., Surface Water Tritium 4.07E+2 (48/272) for Indicator..
Location Mean (Average)] indicate how many samples that specific value and column apply to in relation to the total number of samples for that column heading.
- 8. Air Sampler location 206 (APAC-206) was placed in service April 6, 2009, and the first sample was collected April 13, 2009.
- 9. The tritium reporting limit for Fish is approximately 10.0 pCi/gram as stated in the results from GEL.
- 10. A Shoreline Sediment background sample was collected December 21, 2009 (19 miles N from the plant at Belville Park). A representative Shoreline Sediment evaluation is being conducted to determine an appropriate control sample. The Shoreline Sediment background sample indicated the presence of Cs-137 activity (2.55E-2 pCi/gram - dry single value) along with other naturally occurring gamma activity.
21
INTERPRETATIONS AND CONCLUSIONS Air Monitoring The average gross beta concentration measured in 298 air particulate (AP) samples collected at indicator stations during 2009 was 1.89E-2 picocuries per cubic meter (pCi/m3) and the average gross beta concentration measured in 52 AP samples collected at control stations during 2009 was 1.83E-2 pCi/m 3. The preoperational (1973-1974) average concentration was 8.2E-2 pCi/m3, while the average activity in the recent past (2004-2008) was 1.86E-2 pCi/m 3 (Table 4). The airborne concentrations of gross beta activity in 2009 are indicative of natural background and do not indicate any abnormal activities originating from the nuclear operations at BSEP. Figures 10 through 15 depict the monthly variations of these values. In April of 2009, a new air sampler (APAC-206) was placed in service at the Brunswick Government Complex in Bolivia, N.C.;
which is approximately 11.3 miles NW of the plant site. This air sampler is not an ODCM required location. The air samplers operated for a total of greater than 99% availability for the 2009 year.
Gamma analyses of the composite air particulate filters indicated that all of the radionuclides indicative of plant effluents were at concentrations less than their respective LLDs. All radionuclides positively identified by the radionuclide analyses were typical of naturally occurring materials.
Analyses of 298 indicator and 52 control air cartridges (AC) for the collection of radioiodines indicated that concentrations of those radionuclides, and particularly 1-131, were less than the LLD. No 1-131 activity was identified in any indicator or control samples in 2009.
Milk No milk (milch) sampling locations are currently identified in BSEP environs; therefore, no sampling of this media was available.
Vezetation Food crops were not grown in the vicinity of the plant in 2009, and this media was represented by indigenous vegetation samples consisting primarily of wax myrtle leaves, along with cherry and sweetgum leaves. Fifty-four (54) samples were collected from indicator locations and 15 samples from the control location. No detectable activities relating to plant effluents were detected in this sampling media in 2009, except for three broadleaf (BL) wax myrtle samples sampled February 2, 2009 (BL-803), and May 1, 2009 (BL-801), which indicated Co-60 (cobalt-
- 60) activity (2.63E 7.57E-2 pCi/gram wet). Broadleaf-803 (BL-803) was resampled on February 5, 2009, and the results did not indicate any Co-60 activity (NCR # 319178). However, BL - 801 was resampled on May 6, 2009, and indicated Co-60 activity of 2.3 1E-2 pCi/gram wet) 22
(NCR # 335156). There have been no subsequent environmental vegetation samples which indicated the presence of Co-60. Cesium (Cs)-137 (1.60E 1.78E-2 pCi/gram wet) activity was detected in two (wax myrtle broadleaf samples) out of fifteen control samples. No other gamma activity was detected in any sample, except for K-40 (potassium-40) and other naturally occurring gamma activity.
Fish and Invertebrates Fish (free swimmers and bottom feeders), invertebrate (SH), and benthic organism (BO) samples are collected semiannually from two locations: (1) near the Atlantic Ocean discharge pipe at Caswell Beach and (2) a control location in the Atlantic Ocean not influenced by plant operations and annually from three locations on Nancy's Creek (Figure 4). In all 15 samples (indicator and control), no detectable activities relating to plant effluents were detected in 2009. All radionuclides positively identified by the radionuclide analyses were naturally occurring nuclides.
The fish locations on Nancy's Creek sampled in 2009 were also analyzed for tritium, with all the tritium results being less than LLD.
Groundwater Groundwater is sampled semiannually and quarterly from 40 indicator sample sites. These samples are analyzed for gamma-emitting radionuclides (at least semiannually) and for tritium (at least quarterly). The analyses indicated that no detectable concentrations of gamma emitting radionuclides relating to plant effluents appeared in any of the indicator samples. Analyses indicated detectable concentrations of tritium in 185 out of 403 samples analyzed in 2009. No groundwater samples exceeded reportable concentrations, and there is no indication that the tritium is migrating beyond the Progress Energy owned property through the groundwater.
Shoreline Sediments Two shoreline sediments in 2009 were drawn from the beach area near the pumping station location at Caswell Beach. In both samples, all of the radionuclides indicative of plant effluents were determined to be less than the respective LLDs for gamma-emitting -radionuclides. Three shoreline sediments in 2009 were drawn from Nancy's Creek adjacent to WP-55 near the Storm Drain Stabilization Pond (SDSP), where all three indicator samples contained Cesium (Cs)-137 activity (1.44E 2.03E-1 pCi/gm dry). The samples were analyzed for Iron (Fe)-55, Strontium (Sr)-89, and Strontium (Sr)-90 by GEL, all were less than the respective LLDs. A Shoreline Sediment background sample was collected December 21, 2009 (19 miles N from the plant at Belville Park). The Shoreline Sediment background sample indicated the presence of Cs-137 activity (2.55E-2 pCi/gram - dry single value) along with other naturally occurring gamma activity.
23
Surface Water Surface water (SW) is sampled monthly from the intake and discharge canal and Nancy's Creek is sampled weekly. These samples are analyzed for gamma-emitting radionuclides and for tritium. Tritium analysis is performed weekly on the Nancy Creek samples. Sampling and compositing for gamma emitters is weekly and the gamma analysis is performed monthly on the samples composited weekly. The analyses indicated that no detectable concentrations of gamma emitting radionuclides relating to plant effluents appeared in any of the indicator and control samples. None of the control samples indicated the presence of tritium. However, forty-eight (48) out of 272 indicator samples indicated the presence of tritium in 2009. The predominate location(s) indicating tritium were at Nancy's Creek and the discharge canal indicator locations.
One (1) of the twelve samples from the historical discharge canal indicated the presence of tritium, while forty-seven (47) out of 260 samples from Nancy's Creek indicated the presence of tritium. The tritium activity detected in SW-401 (the discharge canal composite sample) had a single tritium concentration of 5.75E+2 pCi/L, which was expected due to plant operations at the time of sampling. The indicator samples from Nancy's Creek had a maximum concentration of 1.1 OE+3 pCi/L of tritium activity. The reporting limit for tritium in environmental samples is 30,000 pCi/L; therefore, the detected values are well below the reportable limit. Figure 16 depicts the observed tritium concentrations for SW-400 (control) and SW-401 -(indicator) in 2009.
External Radiation Exposure The environmental data on external radiation exposure for 2009 was essentially unchanged from 1989-2008 with an average exposure for all of 2009 indicator locations of 10.0 mR per quarter.
The average exposure observed over the preoperational period was 1.02 mR per week observed from the fourth quarter of 1972 through the second quarter of 1975. Table 5 provides a comparison of recent data with the preoperational and historical data...
The highest average exposure occurred at one TLD location at 619 miles WSW. The exposure was 12.0 mR per quarter. Figure 17 depicts average inner and outerring TLD data for each quarter of 2009. This depiction does not indicate a significant higher exposure rate for the inner versus the outer ring. This is interpreted as demonstrating that no discernible off-site exposure has occurred from plant operations.
24
TABLE 4 Brunswick Steam Electric Plant GROSS BETA AIR PARTICULATE ACTIVITY AVERAGES Gross Beta Activity (pCi/m3)
Preoperational Recent Operational Location 1973 1974 2004 2005 2006 2007 2008 2009 AP-200 2.2E-2 1.4E-1 1.7E-2 1.8E-2 1.9E-2 1.9E72 1.9E-2 1.9E-2 AP-201 3.1E-2 1.4E-1 1.8E-2 1.9E-21 1.9E-2 2.OE-2 1.8E-2 1.9E-2 AP-202 3.4E-2 1.4E-1 1.7E-2 1.7E-2 1.8E-2 1.9E-2 1.9E-2 1.9E-2 AP-203 2.4E-2 1.3E-1 1.8E-2 1.8E-2 1.8E-2 2.OE-2 1.9E-2 1.9E-2 AP-204*
2.5E-2 1.3E-1 1.8E-2 1.9E-2 1.9E-2 2.1E-2 1.8E-2 1.8E-2 AP-205 1.8E-2 1.8E-2 l.8E-2 1.9E-2 1.9E-2 1.9E-2 AP-206*
2.OE-2
- Control location
- This sample point added post-operational.
25
TABLE 5 Brunswick Steam Electric Plant HISTORICAL TLD RESULTS (1972-2009)
Average Exposure of All TLD Monitoring Locations Year (mR per week) 1972 (4th Qtr.)
0.80 1973 1.25 1974 0.97 1975 (1st, 2nd Qtr)
"0.80 1976 0.98 1977 1.32 1978 1.24 1979 0.93 1980 0.90 1981 0.96 1982 1.18 1983 1.21 1984 0.98 1985 1.03 1986 0.89 1987 0.92 1988 0.86 1989 0.75 1990 0:76 1991 0.76 1992 0.75 1993 0.78 1994 0.77 1995 10.1 (mnR per quarter)*
1996 10.1 (mR per quarter) 1997 10.1 (mR per quarter) 1998 9.7 (mR per quarter) 1999 9.7 (mR per quarter) 2000 9.7 (mR per quarter) 2001 10.0 (mR per quarter) 2002 9.6 (mR per quarter) 2003 9.6 (mR per quarter) 2004 9.7 (mR per quarter) 2005 9.8 (mR per quarter) 2006 10.0 (mR per quarter) 2007 9.8 (mR per quarter) 2008 9.9 (mR per quarter) 2009 10.0 (mR per quarter)
- TLD exposure in mR per quarter beginning in 1995. The equivalent weekly exposure is 0.78 mR.
26
MISSED SURVEILLANCES Air Cartridge and Air Particulates Any REMP weekly air samples (Air Cartridge - AC or Air Particulate - AP) that exceed 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> of down time in a surveillance period will be reported as a "missed surveillance."
However, this sample will still be counted and the data reported; whereas a "missed sample" will have no data reported. The air samplers operated for a total of greater than 99% availability for the 2009 year.
All AP and AC samples were available for counting in 2009.
APAC-201; August 12, 2009-Downtime of 17.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> due toan electrical failure of the GFI circuit. An alternate circuit was provided and the sampler repaired and the system returned to service on August 13, 2009 (NCR # 350245).
Food Crops / Vegetation No food crops were grown in the vicinity of the plant in 2009; therefore, none were collected.
The media were represented by indigenous vegetation samples (broadleaf vegetation) consisting primarily of wax myrtle leaves, along with a few cherry and sweetgum leaves.
Thermoluminescent Dosimeters (TLDs)
One out of a possible 180 TLD samples was missing during 2009. The missing TLD occurred:
Fourth Quarter TLD # 8 was missing in the field due to the power pole it was stationed on being replaced, which resulted in the loss of the TLD. A new TLD and holder were installed on the-new power pole in the same location-(NCR #
374236).
27
ANALYTICAL PROCEDURES Gross Beta Gross beta radioactivity measurements are made utilizing a Tennelec Low-Background Alpha/Beta Counting System. The LLD for air particulates is approximately 5.0E-3 pCi/m3.
AP samples are mounted in two-inch stainless steel planchets and are typically counted directly for 50 minutes.
Tritium Liquid samples requiring tritium analysis are treated with a small amount of sodium hydroxide, potassium permanganate crystals, and then distilled. The distillate is mixed with a liquid scintillation cocktail and counted for the appropriate time to reach the desired LLD. The desired LLD was approximately 2.50E+2 pCi/L. This lower LLD was established to compare BSEP tritium LLDs and North Carolina Department of Radiation Protection's reportable concentrations, in the Split Sample Program's Annual Report. The fish samples requiring tritium analysis are analyzed by a vendor laboratory. The ground water samples and most of the surface water samples requiring tritium analysis are analyzed by the BSEP laboratory.
Iodine-131 Iodine-131 airborne concentrations are analyzed by the intrinsic germanium (Ge) gamma spectrometry. systems. The cartridges are placed on the detector and each charcoal cartridge is typically counted individually for 2,500 seconds with an approximate LLD of 5i0E-2 pCi/m3.
Gamma Spectrometry Gamma spectrum analysis utilizes intrinsic germanium detectors with thin aluminum windows housed in steel and lead shields. The analyzer system is the Canberra APEX Gamma Spectroscopy System. Table 6 summarizes LLD values derived from using the instrument with the worst sensitivity, typical sample volumes, typical count times, typical worst background count, and worst case on decay (from collection to counting).
AP filter quarterly composites are placed in a Petri dish and analyzed directly for a typical count time of 7,000 seconds.
Liquid samples are transferred to Marinelli beakers and analyzed by gamma counting. One-liter SW samples are gamma scanned directly in a 1-Liter Marinelli beaker for 60,000 seconds.
28
Shoreline sediments are dried, ground, weighed, and then analyzed in a Marinelli beaker for.a typical count time of 1,500 seconds.
Broadleaf vegetation is weighed wet and analyzed in a Marinelli beaker for a typical count time of 7,500 seconds.
Fish samples are prepared by stuffing small raw, edible portions of the fish in a one liter Marinelli beaker and edible portions of invertebrate organisms are cleanedand placed in a one liter Marinelli beaker for analysis for a typical count time of 1,800 seconds.
Thermoluminescent Dosimetry Each area monitoring station includes a TLD packet, which is a polyethylene bag containing three calcium sulfate phosphors contained in a Panasonic UD-814 badge. The TLD is light tight and the bag is weather-resistant.
Dosimeters are machine annealed before field placement. Following exposure in the field, each dosimeter is read utilizing a Panasonic TLD reader. This instrument integrates the light photons emitted from traps as the dosimeter is heated. Calibration is calculated using dosimeters irradiated to known doses for each set of dosimeters measured. Prior to the measurement of each dosimeter, the instrument is checked through use of an internal constant light source as a secondary standard. The exposure reported is corrected for exposure received in transit and during storage through the use of control dosimeters.
Interlaboratory Comparison Program, The Radiochemistry Laboratory at the Harris Energy & Environmental Center in New Hill, North Carolina, provides radioanalytical services for Progress Energy Carolinas, Inc.'s nuclear plant radiological environmental surveillance programs. In fulfillment of ODCM Operational Requirements, the laboratory is a participant in the Eckert,& Ziegler AnalyticsEnvironmental Cross-Check Programrand uses its performance in this program as a major determinant of the accuracy and precision of its analytical results..
The Interlaboratory Comparison Program entails measurements on each instrument that is used to determine concentrations of radioactive material in the various media that are analyzed as part of the REMP. During 2009, 94 average analyses were completed on 18 samples representing seven major environmental media (i.e., water, milk, air filters, air filters composite, soil, air cartridges, and simulated vegetation). Data on the known activities, the uncertainties, and the ratios to the known for the 94 average analyses have been received from Eckert & Ziegler Analytics. The results were compared to the criteria established in the NRC Inspection Manual (Procedure '.
84750) for Radioactive Waste Treatment, Effluent, and Environmental monitoring (see below results).
'29
All of the 94 average analyses were within the acceptance criteria. During 2009, the individual measurements were evaluated and results falling outside the acceptable ratio criteria will have an evaluation performed to identify any recommended remedial actions and to reduce anomalous errors (NCR # 334599, 360485, and 376364). Complete documentation of any evaluation will be available and provided to the NRC upon request.
Also, included at the end on the report in the Appendix is a summary of General Engineering Laboratories' (GEL's) Interlaboratory Comparison Program results for 2009. Delineated in the results are: the Sample Number or Study ID; Analysis quarter and year; sample media; specific radionuclide; its unit; its result; the known values supplied by the providers; GEL's ratio to the known value or acceptance criteria provided by the provider; evaluation criteria. BSEP's Interlaboratory Comparison Program results are also listed below. Other BSEP Interlaboratory Cross Check Program Results from 2009 will be supplied upon request.
30
7..
- _1 - -. 1 IL-ý.,
HEEC - Interlaboratory Comparison Program Data for 2009 IL7.llL iL 7
-FiI
~~
Results are compared to the criteria established in the NRC Inspection Manual (Procedure 84750) for Radioactive Waste Treatment, Effluents,
,nd Environmental monitoring. The accetable ratio rarre is typicaly 0.80 to 1.25 unless otherwise noted.
Gamma Emitters +1-131 in Milk 4th Q1st Quarter 2009 2nd Quarter 2009 2009......
E6526tr208-66
-EErdtioI EEC KnwnRa ETC Kno R
HEEC Known Ratio HEEC n
E Ve Value Value to Value Value to Value Value to
.L41d (pdl/.!5J.
't!I.&
r (pc !4t r:.;I
'"t.er) ~
.r (pILiter) "Tno
('PC~~eI(~/~le~Ioo 1-131 77.5 79.3 0.98 1
92.8.
_ 94.
0..
'r i304 30,5 1.00 Cs-1341 85.4 93.7 0.91 Cs17 1
113 111 1.02 o-E.19 119 1.*00L2-'
I I Zn-5 161 156 1.03 t.-
Gamma Emitters + 1-131 in Water 4th Quarter ZO8 1st uarter2B09 _
2nd Quarter2009 23rM uarter92009 E6527-668 E6685-868 E6885-668 HEEC Known Ratio HEEC--
Knowný Ratio HEEC Known Ratio HEEC Known Ratio Value Value to Value Value to value value to Value Value to Nuclide (pEILelte) pCJLtr) Known p/Liter) I(pClILlter) Known pliter (i/Liter)
Known (pCi/Uter (pCI/Li ter) Kowný K
_(p L**__,,.o--
-!!ro!!n jp_]
(Pq
.__ 1_
1-131 70.1 69.0 1.02 8M 88.3 11.00 99 98.4 1.01 Ce-141 1
120-219 216i 1.01 265 264 1.00 Cr-Si____
402 387 1.04 306 30
.0 20 212 1.04 Cs-134 109 119 0.92 119 126 40.94 Ill1 118 0.94 Cs13.4~144
_1411.2 15 14 10 183 177_
1.03 Co-58 151 151 1.00 71 69.8 1.02 97 95.4 1.02 Mn--
173 162 1
108 104 1.04 202 198 1.02 13
- 3.
127 1.00
.. 98 92.9 1.05 156 141 1.11 Zn-65
_____206 197 1.05 147 133 1.11 217 195 1.11 Co-60 189 100 1.05 246 237 1.04-160 4
1...
Beta.ater...
_~~-
7--
Gross Beta (Cs-137) In Water
FT7-----T--*
r[
,..4th Quarter 2M00 1st Quarter 2009 __
2nd Quarter 2009 3rd Quarter 2009
_______E__6413-668 E6525-668
____E6896-66 HEEC Known Ratio HEEC Known Ratio HEEC Known Ratio HEEC Known Ratio SValue Value to Value iValue
]to value Ivalue to Value
' Value to Nuclide (p!l/Utej(iItrKnw (plLe)(p/le)
Known (pl/ter) pI/pl/ter) Known (pCi/Lt-er) pKi/LLiter)- Know Gross
{
Beta 145 130 1.12 239 235
_1.02 215 223 0.96 Tritium In Water I
4thQuarterz28 s Qa E6411-668
_________E652 rter 2009 4-668 l
nd Quarter 2009 "EEC Known Ratio Value Value to (pCI/Liter) (pCI/Liter) Known Nuclide H-3_
HEEC Known Ratio Value Value to (pd/Liter) r,
10109o 10000 0.99 HEEC Known Ratio Value Value to (pCI/Lter). (pCi/Liter) Known 4560 4480.011.02 3rd Quarter 2009 HEEC..
Value Value to
_(pCl/Ller )_IpCi/Liter KInown~
'I.
31
Gampma ETmiter In Simulaated Vegetation
.~7
§ L i1 L 2nd Qatr~
3rdOuater 2009 Nuclide
.Ce-141 Cr-51
_Cs-134 Cs 137
.Co-58 Fe-59 Zn-65 "EEC Known Value Value (plJter)
(pClI/LLterI_
Ratio to Known E.I 6528-668
-* - --L :--
-- ) '*4 HEC Known Ra t Io ale Value to
_j(PCVgamTj(Pd/rava) now 2 015 L0.123 1.02 0 402 0.. 395 1.02 0.113 0.12 _
0.93 0.145 044 1.01 S013 0.154 0.99
- o.
o0.202 29 1.05 n 187 o
m-8-*
.0i-2 IHEEC Value (pd/gram).
now.
Ratio Value ItoI_ a5-:.:
own_::
1HEEC Value (pli/gram)
Value (pCilgrarn).
eam Ratio to Known j
~
.j~
I I
-I------------------. I-
'K-
.f........
qross Beta Filter'___
E6412-668 HEEC Known Ratio HEEC Known Ratio Value Value to Value value to Nuclide (pCl/Flite~r) (pd/Flite!r' Knows' IlpEdFllerij(pa/Flteri) Kown et 11 10 OGross I
Iý 1
-F T
1-131 on Face Loaded Charcoal Cartridge "SEEC Known Rtio VI.E Know Rati Value Value to "e
Value to Nudlde (pcl/UnUt)
(p/Unt) n t)
W(l/Unlt) Known
-1uaet 53.3 1.04 rt_
Gamma Filter 1
4th Quarter 2M1' Ist Quarter 2009 2nd Quarter 2009 HEEC Known value Value 83.5 8
Ratio to Known 0.98 3rd ruarw 2009 HEEC' Known I
Value Value
'i/Fifter)
KpCI/F~ler' K
Ratio to (nown
.4-..--
~~1 2.-.~.
2nd HEEC Value,,
(pdl/UnIt) 94.1 Quarter 2009 6688-668 Known Ratio Value )
to (pCJLanlt) Known 9.7.
0__.98P-*
3rd Quarter 2009 HEEC Known f Rtto Value
- jValue, to (pCIL/tnlt) j (pCI/UnIt) anow
"-'Ti I
I
---.4 HEEC Known Ratio tValue Value to (K1.Uteýrp!/U Kn!ow HEEC Value non Ratio Value Ito (pCI/grmT)_Ko 2nd HEEC Vrale 186
..uarter 29 Known Ratio Value to 188 0.99 3rdQuarte_2009 ___
E61118-668 HEEC Know-Ft 0
Value Value.
to pc lgrns 1pCI/gra' w1 181 180 1.01-,
Nulide Ce-141 Cr-S1 CýS-134_
Cs-137 Co-58
_Mn-54 Fe-59 7n-&%
t----
249 013.
1I127 265 0.94
]__.4
__M 110 0.98 79
- --80.6-127 1.00 M
12 1 121 9(0.984 6 1 6
0.8 1.00 95 90.7 1.0 92 I 81 1.4 66 114.
135 96.3" 1iHt 1.01 1.09 1.18-1.lq 137 116 1.IR 15R
-~
i-=-+~+
v-q-Co-am Gamma 13_FilterCopst 4th Quarter 2008 HEEC Known Rai Value Value to (pKl/tr)_ JKpal/Utr):Know 211 206_.o 1.02 104 10.....0 *.99.
HEEC Known -Rail 0
Value Value Jto
.iPI/ranlIpI/sanlKnown 2nd Quarter 2009 Nudlide Ce-141 Cs-137 HEEC Value 2_73 388 158 19u0f 6681-668.
Known Value 280 394 163
-18,9 Ratio to Known 0.98 1L.01 "3rd Quarter 2009 HEEC jKnown R
Value Value j-Vgr atlf to Co-S8
.... -94g Fez-.9 V
94 143 134 202 311 9 0.5 099 135 1.06
.. L_2J...
120.12I 32
BSEP 2009 Interlaboratory Cross Check Performance Summary for Environmental Sample Media Types Analyzed Sample Nuclide Quarter Units BSEP EZA BSEP/EZA Evaluation Value Value Ratio Tritium in Water H-3 1st
[iCi/cc 8.55E-4 9.04E-4 0.95 Agreement 3 rd ACi/cc 1.04E-3 1.09E-3 0.96 Agreement Solid Ce-141 3rd
ýtCi 6.81E-2 6.86E-2 0.99 Agreement 4th RCi 4.13E-2 4.24E-2 0.97 Agreement 4 th RCi 2.86E-2 2.96E-2 0.97 Agreement Cr-51 3rd 11Ci 6.2 1E-2 6.26E-2 0.99 Agreement 4
1Ci 1.23E-1 1.27E-1 0.97 Agreement 4 th RCi 8.81E-2 8.85E-2 1.00 Agreement Cs-134 3rd RiCi 1.45E-2 1.54E-2 0.94 Agreement 4 th jCi 2.75E-2 3.05E-2 0.90 Agreement 4 th
[Ci 2.19E-2 2.13E-2 1.03 Agreement Cs-137 3 rd pCi 2.22E-2 2.24E-2 0.99 Agreement 4 th jCi 2.1OE-2 2.11E-2 0.99 Agreement 4_th
_iCi 1.52E-2 1.47E-2 1.03 Agreement Co-58 3rd pCi 1.65E-2 1.68E-2 0.98 Agreement 4 th PCi 3.13E-2 3.24E-2 0.97 Agreement 4_th
_tCi 2.28E-2 2.26E-2 1.01 Agreement Mn-54 3 rd PCi 2.78E-2 2.69E-2 1.03 Agreement 4_th
_Ci 2.17E-2 2.22E-2 0.98 Agreement 4 th ptCi 1.55E-2 1.55E-2 1.00 Agreement Fe-59 3 rd PCi 3.19E-2 3.02E-2 1.06 Agreement 4 th PCi 3.22E-2 3.19E-2 1.01 Agreement 4 th PCi 2.32E-2 2.22E-2 1.05 Agreement Zn-65 3rd
[LCi 3.06E-2 2.7-1E-2 1.13 Agreement 4th
_PCi 4.44E-2 4.39E-2 1.01 Agreement 4_th
_LCi 3.14E-2 3.06E-2 1.03 Agreement Co-60 3rd pACi 1.96E-2 1.96E-2 1.00 Agreement 4_th PCi 2.89E-2 3.03E-2 0.95 Agreement 4T' pCi 2.1OE-2 2.11E-2 1.00 Agreement 33
Lower Limits of Detection All samples analyzed met the LLD required by the ODCM. Typical "a priori" LLD values for the samples analyzed are listed in Table 6.
34
TABLE 6 TYPICAL LOWER LIMITS OF DETECTION (A PRIORI)
GAMMA SPECTROMETRY Surface Water Samples (Saline Water*
Isotope LLD (pCi/l)
Mn-54 3
Co-58 3
Fe-59 7
Co-60 3
Zn-65 6
Zr-Nb-95 6/4 1-131 14 Cs-134 3
Cs-137 3
Ba-La-140 25/8 Air Particulates (Quarterly Composite)
Isotope LLD (pCi/m3)
Cs-134 0.002 Cs-137 0.001 Shoreline. Sediment Isotope LLD (pCi/kg, dry)
Cs-134 65 Cs-137 45' Fe-55 (Hard-to-detect [HTD])
20,000 Sr-89/90 {HTD]
2000 / 2000 Fish Isotope LLD (pCi/kg, wet)
Mn-54 38 Co-58 42:
Fe-59 106 Co-60 40ý Zn-65 79 Cs-134 44 Cs-137 38 Food Products and Vegetation,
-_LLD (pCi/kgWet),.-
1-131 52.8 Cs-134.
44 Cs-137 36 35
LAND USE CENSUS PURPOSE OF THE LAND USE CENSUS The land use census identifies the pathways (or routes) that radioactive material may reach the general populations near commercial nuclear generating stations. This is accomplished by completing studies each year that identify how the surrounding lands are used by the population.
A comprehensive census of the use of the land within a five-mile distance of the plant is completed during the growing season each year. This information is used for dose assessment and to identify changes to the stations sampled and the type of samples. These results ensure that the Radiological Environmental Monitoring Program (REMP) is based upon current data regarding human activity in the vicinity of the plant. Therefore, the purpose of the land use census is both to ensure the monitoring program is current as well as to provide data for the calculation of estimated radiation exposure.
The pathways that are evaluated are:
> Ingestion Pathway - Results from eating food crops that may have radioactive materials deposited on them from the atmosphere or contain radioactive materials from the soil.
Another pathway is through drinking milk from local cows or goats if these are present.
The grass used to feed these animals may have incorporated or had deposited on it radioactive materials that can be transferred to the milk.
> Direct Radiation Exposure Pathway - Results from deposition of radioactive materials on the ground or from passage of these radioactive materials in the air.
>' Inhalation Pathway - Results from breathing radioactive materials transported in the air.
36
Methodology The following must be identified within the five-mile radius of the plant for each of the 16 meteorological sectors (compass direction from which the winds may blow, for example NNE
[North North East]):
> The nearest resident
)> The nearest garden of greater than 500 square feet, producing broadleaf vegetation
)
The nearest milk animal The following must also be identified (for elevated releases) within the three-mile radius of the plant for each of the 16 meteorological sectors:
> The location of all milk animals
> The location of all gardens of greater than 500 square feet, producing broadleaf vegetation The primary method is visual inspection from roadside within the five-mile radius, with the exception of the Sunny Point Military Ocean Terminal. This information may be supplemented with data from aerial photographs and a Global Positioning System (GPS) to determine distance and direction from the plant.
2009 Land Use Census Results The 2008 and 2009 results of the survey for the nearest resident, garden, milk and meat animals in each sector are compared in Table 7.
The resident portion of the census conducted in June of 2009 did not identify changes in the identity of the nearest resident from plant center from 2008. The garden portion of the census identified changes in the distances, locations, and existence of the nearest garden in seven sectors during the 2009 census.
The nearest garden location changed in the North (N) sector from a garden at 1.0 miles to no garden, the South (S) sector from 1.8 miles to 2.0 miles, the South Southwest-(SSW) sector from 1.9 miles to 2.0 miles, the Southwest (SW) sector from 3.0 miles to 1.6 miles, the West (W) sector from 1.0 mile to 0.9 miles, the Northwest (NW) sector from 4.9 miles to 1.0 mile, and the North Northwest (NNW) from 0.9 miles to 0.9 miles (different location). No milk animals-were located within 5 miles of the plant in 2009.
The 2009 Garden Census was conducted within 3 miles of BSEP and identifies all gardens of greater than 500 square feet that were found in the survey area. Results of the garden census are located in Table 8.
Results of the 2009 Land Use and Garden Census indicate stable use of land, confirming that current control locations are appropriate, and no changes are needed for dose assessment and environmental motoring.
37
TABLE 7 Brunswick Steam Electric Plant LAND'USE CENSUS COMPARISONS (2008-2009)
NEAREST PATHWAY (MILES)
SECTOR RESIDENT GARDEN MILKIMEAT ANIMALS 2008 2009 2008 2009 2008
[
2009 N
0.7 0.7 1.0 None*
None None NNE 0.8 0.8 0.9 0.9 None None NE None None None None None None ENE None None None None None
.. None-.
- E NNone NoneNone None None.
None ESE 1.4 1.4 1.4 1.4 None None SEý None None None None
- None, None*
.2.1 2.1 None None None None S
1.1 1.1 1.8 2.0*
- 1.
2.0*
None None WSW 1.2 1.2 1.2 1.2 None None W
0.9 0.9 1.0 0.9*
None None WNW 0.9 0.9 None None None None NW 0.9 0.9 4.9 1.0*
None None NNW
.0.8 0.8 0.9.
0.9*
- Represents a change from the previous year.
38.
TABLE 8 Brunswick Steam Electric Plant GARDEN CENSUS (2009)
SECTOR DISTANCE SECTOR DISTANCE (miles)
. (miles)
N None WSW 2.1 NNE 0.9 WSW 2.9 NE None WSW 3.0 ENE None WSW 3.0 E
None W
0.9 ESE 1.4 W
0.9 SE None W
1.0 SSE None W
2.5 S
2.0 W
2.6
.S 2.3 W
2.6.
SSW 2.0 W
2.7 SSW 2.1 W
2.7 SSW 2.1 W
2.7 SSW 2.2 W
2.7 SSW 2.2 W
2.7 SSW 2.3 WNW None SSW 2.3 NW 1.0 SSW 2.3 NW 4.4 SSW 2.7 NW 4.9 SSW 2.7 NNW 0.9 SSW 2.8 NNW -.
43 -
SSW 2.8 NNW 4.5 SW 1.6 NNW 4.6
.. SW 2-2
-NNW 4.6-SW 2.9 NNW 4.6 WSW 1.3 NNW 4.7 WSW 1.3 NNW 4.8 WSW 1.6 NNW 4.8 WSW 2.1 NNW 5.0 39
Figure 10 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
Location 200 1.0 MI WSW-VISITORS CENTER lb-U--Location204 22.4 MI NNE-SUTTON PLANT (CONTROL) 0.03
°* 0.025 -
t 0.02 II 0.015 t
4 20.015-0.005 0 _1 Jan-09 Apr-09 Jul-09 Oct-09 Date 40
Figure 11 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
Locaion 201 0.5 M! NE-PMAC
-,,I-Locaon 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 0.03 0.025 I
0.02 t
I I,l 0.015 atI 0.005 0
Jan-09 Apr-09 Jul"9 0
ct-09 Date 41
Figure 12 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
Locta*n 202 10 MIS-SUBSTATION ON CONSTRUCTION RD
-4b--Locison204 22.4MI NNE -SUTTON PLANT (CONTROL) 0.035 0.03 A
0.025 w
0.02 0.015 m
0.01 0.005 -
0
_4 Jan-09 Apr-09 Jul-09 Oct-09 Date 42
Figure 13 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
- --Location 203 2.0 MI SSW - SOUTHPORT SUBSTATION
-l-0
.Location 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 0.03 0.025i 0.015 Ii o
I Ia I
0.01 0.005 0 _
Jan-09 Apr-09 Jul-09 Oct-09 Date 43
Figure 14 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
Location 205
.6M! SSE - SPOIL POND
-,,0--Location204 2AMI NNE -SUTTON PLANT (CONTROL) 0.035 0.03 -
0.015 0.005 0
Jan-09 Apr-09 Jul-09 Oct-09 Date 44
Figure 15 For BSEP from 1/1/2009 To 12/31/2009 AIR PARTICULATE for GROSS BETA - Activity (pCi/cubic meter)
Locatbon 206
.13 MILeS NW FROM PLANT AT BRUNSWICK COUNTY GOVERN. COMPLEX
- -G-,
Locaton 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 0.035 0.03 4 i
4 f
St I
M -
0.025
-.4 Nlr.
ý, h
- '1, I
- t S
5~9
- a
~LI A
It U,
- t I,
I I-A tat' IAt
'I I
I?
RI Z-0.02 0.015 S
S I-U I
I,
'S I
U-I I
I I
-~\\ /iota I
-a i
'I II A'S rI~b I
II(M~t 0.01 i
0.005 0 4-Jan-09 Apr-09 Jul-09 Date Oct-09 45
Figure 16 BSEP 2009 Surface Water Tritium Location 400 (control) -
Location 401 -
-A - - Tritium LLD (250 pCi/Liter) -
EPA Drinking Water Level I-S
-J Ua.
21000 20000 19000 18000 17000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0
i i
i i
i
-4
-4 Ti>,'
.4
-4
-4
-4
-4
-4 I4
-4 I4
-I I,
I 1/1 2/1 3/1 4/1 5/1 6/1 7/1 8/1 9/1 10/1 11/1 12/1 Dates 46
Figure 17 BSEP 2009 TLD Averages for Inner and Outer Ring Locations 10.8 10.6 -
10.4 10.2
-0 0 96 8.8 68.6 Io-ly
.0 Lo-9ua.
so 31 15-Feb09 15-Feb-09
-May-09 15-May-09 15-Aug-15-Aug-OS 5-Nov-OS 15-Nov-09 Inner Outer Inner Outer Inner Outer Inner Outer Dates 47
APPENDIX The attached information contains the 2009 Interlaboratory Comparison Program Report supplied by GEL Laboratories LLC. Any additional information will be supplied upon request.
48
ELaijoratories u.c.
a member of The GEL Group INC PO Box 30712 ChadestnSC29417 2040 Savage Road Chadeston.
SC 20407
-1843.056.8171 F 843.766.1178 Www.gol.com 2009 INTERLABORATORY COMPARISON PROGRAM REPORT In accordance with US Nuclear Regulatory Commission requirements, GEL Laboratories, LLC (GEL) participates in an Interdaboratory Comparison Programs (ICP) that satisfies the requirements of both Regulatory Guide 4.15, Revision 1, "Quality Assurance for Radiological Monitoring Programs (Normal Operations) - Effluent Streams and the Environment", February 1979 and Regulatory Guide 4.15, Revision 2, "Quality Assurance for Radiological Monitoring Programs (Inception through Normal Operations to License Termination) - Effluent Streams and the Environment", July, 2007. Both guides indicate the ICP is to be conducted with the Environmental Protection Agency (EPA) Environmental Radioactivity Laboratory Intercomparison Studies (Cross-check) Program or an equivalent program, and the ICP should include all sample medium/radionuclide combinations that are offered by the EPA and included in the REMP.
Intefcomparison samples, were obtained from Eckert & Zeigler Analytics of Atlanta, Environmental Resource Associates of Arvada, Colorado and the Mixed Analyte Performance Evaluation Program (MAPEP). Each provider has a documented Quality Assurance (QA) program and the capability to prepare Quality Control (QC) materials traceable to the National Institute of.Standards andTechnology.
The ICP is a third party blind testing program which provides a means to ensure independent checks are performed on the accuracy and precision of the measurements of radioactive materials in environmental sample matrices. The providers supply the crosscheck samples to GEL. Upon receipt, the laboratory performs the analyses in a normal manner. The results are then reported to the provider for evaluation.
The samples offered by ICP providers and included in GEL's analyses are gamma isotopic analyses of an air filter, milk, water, soil and vegetation, Sr-89/90 in Milk and water and 1-131 in cartridges. The accuracy of each result reported to Analytics, Inc is measured by the ratio of GEL's result to the known value. Accuracy for all other results is based on statistically derived acceptance ranges calculated by the providers. An investigation is undertaken whenever the ratio or reported result fell outside of the acceptance range.
A summary of GEL's results is provided in the tables below for the required sample matrix types and isotopic distribution. Delineated in the table are: the Sample Number or Study ID; Analysis quarter and year; sample media; specific radionuclide; its unit; its result; the known values supplied by the providers; GEL's ratio to the known value or acceptance criteria provided by the provider; evaluation criteria.
GEL analyzed 31 samples for 151 parameters in 2009. All results except one met the acceptance criteria and are discussed below.
- The root cause of the Sr-90 failures was determined to be a batch quality control issue. The carrier yield for the second separation was greater than 100%. The elevated yield caused the Sr-90 result to be biased low. Even though the yield fell within its acceptance range, if problem solved 49
GEL Laboratories, LLC February 2, 2010 2009 Interlaboratory Comparison Study Page 2 of 5 adjusted to reflect recoveries typically observed in this procedure, the sample results would be within the acceptance range.
Quarter I Sample Analyte I GEL Known Acceptance Sample Number Year Media Unit Nuclide Value value Range/Ratio Evaluation E6582-278 1-1/2009 Cartridge Loi 1-131 7.77E001 7.94E+01 0.98 Acceptable E6584-278 1'/12009 Milk pCilL Ce-141 9.78E+01 9.49E+01 1.03 Acceptable E65684-278 1-1/2009 Milk pCitL.
Co-58 1.23E.02 1.19E+02 1.03 Acceptable E6584-278 1 /2009 Milk p~i/L Co-60 1.50E+02 1.42E+02 "1.05 Acceptable E6584-278 1u / 2009 Milk pCilL Cr-51 2.97E402 3.05E+02 0.97 Acceptable E6584-278 13'/2009 Milk pCi/L Cs-134 9.06E401 9.37E+01 0.97 Acceptable E6584-278 1/2009 Milk pCilL Cs-137 1.16E402 1.11E+02 1.04 Acceptable E6584-278 lU/2009 Milk pCil/L Fe-59 1.16E+02 7.61E+00 1.16 Acceptable E6584-276 1u/2009 Milk pCil/
1-131 "
7.97E+01 7.93E+01
-1.01 Acceptable E6584-278 10/2009 Milk pCi/L Mn-54 1.33E+02 1.28E+02 1.04 Acceptable E6584-278 1=t/2009 Milk pCi/L Zn-65 1.72E+02 1.56E+02 1.1 Acceptable E6585-278
'1/2009" Water pCi/L Ce-141 1.22E+02 1.20E+02 1.02 Acceptable E6585-278 1 /2009 Water pCi/L CO-58 1.59E+02 1.51E+02 1.05 Acceptable E6585-278 1.=/2009 Water pCi/L co-60 1.92E+02 1.60E+02 1.06 Acceptable E6585-276 1C/12009 Water pCi/.
Cr-51 3.92E+02 3.87E+02 1.01 Acceptable E6585-278 V1=2009 Water pCi/l Cs-134 1.19E*02 1.19Ef02 1.00 Acceptable E6585-278 1C/2009 Water pCi/I Cs-137 1.44E+02 1.41E÷02 1.02 Acceptable E6585-278 11 / 2009 Water pCUL Fe-59 1.28E+02 1.27E402 1.01 Acceptable E6585-278 1W/2009 Water pCil.
1-131 7.55E+01 6.90E÷01 1.09 Acceptable E6585-278 1-/2009 Water pCi/l Mn-54 1.80E+02 1.62E+02 1.11 Acceptable S"E6585-278 1912009 Water pCi/L Zn-65 2.24E+02 1.97E+02.
1.13 Acceptable RAD - 76 1 1/2009 Water pCi/L Gross Alpha 51.3 52.3 27.3-65.5 Acceptable RAG - 76 1-t/2009 Water pCi/L Gross Beta 41.9 46.1 31.0- 53.3 Acceptable RAD - 76 1-t / 2009 Water pCi/L H-3 3760.0 4230 3610 - 4660 Acceptable RAD-76 1-1/2009 Water pCi/L 1-131 25.1 22.2 18,4-26.5 Acceptable RAD - 76 1 ' / 2009 Water pCitL Sr-89 72.8 65 52.7-73.0 Acceptable RAD - 76 111 / 2009 Water pCVIL Sr-90 36.5 41.9 30.8-48.1 Acceptable E6729-278 2nd / 2009 Cartridge pCi 1-131 9.27E+01 9.55E+01 0.97 Acceptable E6730-278 2nd /2009 Milk pCi/I Sr-89 8.51E+01 1.12E+02 0.76 Acceptable Not E6730-278 2" /2009 Milk pCi/L Sr-90
'1.09E401 1.67E+01 0.65 Acceptable E6731-278 2'd 12009 Milk pCilL Ce-141 2.84E+02 2.04E+02 1
Acceptable E6731-278 2r" / 2009 Milk pCiIL Co-58 9.48E+01 9.19E+01 1.03 Acceptable E6731-278 2- / 2009 Milk pCi/L Co-60 3.1SE+02 3.12E÷02 1.01 Acceptable GEL Laboratorles iic P0O8.30712 oar*ln..SC29417 204OSwaq.uoa Cftzult.c.SC29407 Pae455&1u71 FR3.76a,118 vww..gn.n 50
GEL Laboratories, LLC February 2, 2010 2009 Intertaboratory Comparison Study Page 3 of 5 Milk I pCitL I Cr-51 I4.04E+02 I 4.000402 1 1.01 Acceptable E6731-278 2 md 12009 E6731-278 2-4 12009 Milk pCilL Cs-134 1.58E+02 1.66E+02 0.95 Acceptable E6731-278 2ýd /2009 Milk pCilL Cs-137 1.92E+02 1.92E+02 I
Acceptable E6731-278 2nýd /12009 Milk pCilL Fe-59 1.23E*02 1.22E+02 1.01 Acceptable E6731-278 2nd /2009 Milk pCilL 1-131 8.98E+01 1.02E+62 0.88 Acceptable E6731-278 2nd /2009 Milk pCi/L Mn-54 1.42E+02 1.37E-02 1.04 Acceptable E6731-278 2nd /12009 Milk pQilL Zn-65 1.79E402 1.75E+02 1.02 Acceptable E6732-278 2nd 12009 Water pCi/L Ce-141 2.29E+02 2.16E+02 1.06 Acceptable E6732-278 2nM / 2009 Water pCi/L Co-58 7.21E+01 6.981101 1.03 Acceptable E6732-278 2d /12009 Water pCi/L Co-60 2.42E+02 2.37E-02 1.02 Acceptable E6732-278 2nd /2009 Water pCi/l Cr-51 3.114E02 3.04E002 1.02 Acceptable E6732-278 2m / 2009 Water pCiL Cs-134 1.37E+02 1.26E+02 1.09 Acceptable E6732-278 2.d /2009 Water pCi/l Cs-137 1.51E+02 1.46E402 1.04 Acceptable E6732-278 2md 12009 Water pCi/L Fe-59 9.04E+01 9.29E+01 0.97 Acceptable E6732-278 2nd 12009 Water pCi/l 1-131 8.52E+01 8.83E+01 0.97 Acceptable E6732-278 2d /12009 Water pC/IL Mn-54 1.07E+02 1.04E+02 1.03 Acceptable E6732-278 2-d /2009 Water pCi/L Zn-OS 1.38E+02 1.33E+02 1.04 Acceptable MAPEP 09-GrF20 2nd / 2009 Filter Bg Gross Alpha 0.069 0.35
>0.0 - 0.696 Acceptable..
'MAPEP 09-GrF20 2nd /2009 Filter Bg Gross Beta 0.297 0.28 0.140 - 0.419 Acceptable MAPEP 09-GrW20 2w /12009 Water Bq/L Gross Alpha 0.506 0.64
>0.0 - 1.270 Acceptable MAPEP 09-GrW20 2-d /12009 Water Bq/L Gross Beta 1.337 1.27 0.64-1.91 Acceptable MAPEP 09-MaS20 2- /12009 Seil Bq/kg Co-57
-0.30 0.00.
Acceptable MAPEP09-MaS20 2nd /2009 Soil Bqtkq Co-60 3.6 4.113 Acceptable MAPEP 09-MaS20 2nd / 2009 Soil Bq/kq Cs-I34 468 467 327-607 Acceptable MAPEP 09-MaS20 2- / 2009 Soil Bq/kg Cs-137 622 605 424-787 Acceptable MAPEP 09-MaS20 2Vd /2009 Soil Bq/kq Fe-55 844.7 983 688-1278 Acceptable MAPEP 09-MaS20 2- /2009 Soil B/okq K-40 608.7 570 399-741 Acceptable MAPEP 09-MaS20 2nd /2009 Soil Bq/k Mn-54 322.3 307 215-399 Acceptable MAPEP 09-MaS20 2" /12009 Soil Bq/kg Ni-63 550.3 514.9 360.4 - 669.4 Acceptable MAPEP 09-MaS20 2Nd / 2009 Soil Bq/kg Sr-90 262.33 257 180- 334 Acceptable MAPEP 09-MaS20 2V / 2009 Soil Bq/kg Zn-65 261 242 169 -315.
Acceptable MAPEP 09-MaW20 2nd 12009 Water Bq/L Co-57 18.8 18.9 13.2-24.6 Acceptable MAPEP 09-MaW20 2N 1 2009 Water BqlL Co-60 16.8 17.21 12.05 - 22.37 Acceptable MAPEP 09-MaW20 2nW
/12009 Water BqIL Cs-134 21.9 22.5 15.8-29.3 Acceptable MAPEP 09-MaW20 2"d/ 2009 Water BqlL Cs-137 0.0 0
Acceptable MAPEP 09-MaW20 2-d / 2009 Water B§gL Mn-54 15.1 14.66 10.26 - 19.06 Acceptable MAPEP 09-MaW20 2n 12009 Water Bq/L Ni-63 52.7 53.5 37.45-69.55 Acceptable MAPEP 09-MaW20 2- / 2009 Water Bg/L Sr-90 7.43 7.21 5.05-9.37 Acceptable MAPOP 09-MAW2O 1
29 / 2009 W.ter Bo/l Z7,.65 14 6 1.16 A I
- 17.7 1 A
.narlahla MAPEPO9-RdF20 1n 2-12.
1
ý i iiI ______
1 1.347 if
- .3;
-. 6 GEL taborateries 11.C POr3oenxpr ohwAmt.SC2%417 204OSwPongoad Qwnt.1Sn~C2947 P64%56.81e71 F64&78.1178pdsn.nInn 51
GEL Laboratories, LLC February 2, 2010 2009 Interlaboratory Comparison Study Page 4 of 5 MAPFP ne.OAF9OI n
tO I
Fil Co-eP I i 411 I l)~' I 005-150 Ae.r~otahle Rn MAPEP 09-RdF20 21d /2009 Filter Bq Cs-1134 2.763 2.93 205-3.81 Acceptable MAPEP 09-RdF20 2nd /2009 Filter Bg Cs-137 1.487 1.52 1.06-1.98 Acceptable MAPEP 09-RdF20 2"d /2009 Filter Bg Mn-54 2.403 2.27 1.5896 - 2.9522 Acceptable MAPEP 09-RdF20 2m / 2009 Filter B*
Sr-90 0.692 0.64 0.448 - 0,832 Acceptable MAPEP 09-RdF20 2nd /2009 Filter Bg Zn-65 1.613 1.36 0.95-1.77 Acceptable MAPEP 09-RdV20 2M /2009 Vegetation ug/sample Co-57 2.557 2.36 1.65-3.07 Acceptable MAPEP 09-RdV20
.2d /2009 Vegetation ug/sample Co-60
-0.010 0.00 Acceptable MAPEP 09-RdV20 214 /2009 Vegetation uo/sample Cs-134 3.430 3.40 2.38-4.42 Acceptable MAPEP 09-RdV20 20d 12009 Vegetation ug/sample Cs-137 0.907 0.93 0.65-1:21 Acceptable MAPEP 09-RdV20 2nd /2009 Vegetation ug/sample Mn-54 2,353 2.30 1.61 -2.99 Acceptable MAPEP 09-RdV20 2md /2009 Vegetation ug/sample St-90 1.160 1.26 0.882 - 1.638 Acceptable MAPEP09-RdV20 2'* /2009 Vegetation ag/sample Zn-O5 1.350 1.35 0.948 1.760 Acceptable E6843-278 3 d / 2009 Cartridge pCi 1-131 9.54E+01 9.21E+01 1.04 Acceptable E6844-278 34/12009 Milk pCi/L Sr-89 1.19E+02 1.07E+02 1.12 Acceptable E6844-278 3
1/2009 Milk pCi/L Sr-90 1.68E001-1.88E+01 0.89 Acceptable E6845-278 36/2009 Milk pCiL Ce-141 2.83E+02 2.75E+02 1.03 Acceptable E6845-278 3 d 12009 Milk pCi/L Co-58 1.04E+02 9.94E+01 1.05 Acceptable E6845-278 3 rd / 2009 Milk pCi/L Co-60 1.58E+02 1.60E+02 0.99 Acceptable E6845-278 3rd /2009 Milk pCi/L Cr-51 2.43E+02 2.21E+02 1.1 Acceptable E6845-278 3 r/ 2009 Milk pCiUL Cs-134 1.23E+02 1.23E+02 1.00 Acceptable E6845-278 3 d 12009 Milk pCi/L Cs-137 1.92E+02 1.85E÷02 1.04 Acceptable E6145-278 3 d /2 0 0 9 Milk pCi/L Fe-59 1.64E+02 1.47E+02 1.11 Acceptable E6845-278 3'd12009 Milk pCi/L 1-131 1.01E+02 9.80E+01 1.02 Acceptable E6845-278 3 rd 12009 Milk pCi/L Mn-54 2.11E+02 2.06E+02 1.02 Acceptable E6845-278 30112009 Milk pCi/l.
Zn-65 2.24E+02 2.0+02 1.1 Acceptable E6846-278 3 d/2009 Water pCiL.
Ce-141 2.72E+02 2.04E+02 1.03 Acceptable E6846-278 31412009 Water pCilL Co-5 9.65E+01 9.54E+01 1.01 Acceptable E6846-278 3,/12009 Water pCV/L Co-60 1.56E+02 E+02 +02 1.01 Acceptable E6846-278 31412009 Water pCi/L Cr-51 2.21E+02 2.12E+02 1.04 Acceptable E6846-278 3 8d/2009 Water pCU/L Cs-134 1.18E+02 1.08E+02 1.00 Acceptable E6846-278 301/2009 Water pCi/L Cs-137 1.86E002 1.77E+02 1.05 Acceptable E6846-278 3,d / 2009 Water pCi/L Fe-59 1.48E+02 1.41E+02 1.05-Acceptable E6846-278 3 Id / 2009 Water pL 1-131 1,02E+02 9.84E+01 1.04 Acceptable E6846-278 3 d 12009 Water pCi/L Mn-54 2.110E+02 1.98E+02 1.07 Acceptable E6846-278 3 a 12009 Water pCi/L Zn-65 2.19E+02 1.95E+02 1.12 Acceptable RAD - 78 3,d / 2009 Water pCi/L Gross Alpha 43.8 55.3 28,9-69.0 Acceptable RAD - 78 3rd / 2009 Water pCi/L Gross Beta 53.6 64,7 44.8-71.3 Acceptable RAD - 78 3-d/2009 Water pCi/L H-3 9440.0 10000 8600- 11000 Acceptable GEL Labaratories r..c POBU30712 ChaOd~
NSC29417 20OoSaoR*2red Chnrrnen.SC2%407 P843.556.8171 F843.768.1178 - Y-021-,nn 52
GEL Laboratories, LLC February 2, 2010 2009 Interlaboratory Comparison Study Page 5 of 5 RAI'). 7A
.A d I 9O)t W~t~r COfiI 1.1311 7114 I 9R3 1 21.91 A-III I Acerp obtals RAO -78 3 0/ 2009 Water pCi/L Sr-89 59.6 59.1 47.4 - 66.9 Acceptable RAD -78 3 'w 12009 Water pCilL Sr-90 33.7 37.4 27.4 - 43.1 Acceptable MAPEP 09-GrF21 4' /12009 Filter Bq Gross Alpha 0.069 0.35
>0,0 -0.696 Acceptable MAPEP 09-GrF21 41" J 2009 Filter Bq Gross Beta 0.297 0.28 0.140 -0.419 Acceptable MAPEP 09-GrW21 4"' 12009 Water Bg/L Gross Alpha 0.982 1.05
>0.0 -2.094 Acceptable MAPEP09-GrW21 4'! 12009 Water Bg/L Gross Beta 7.277 7.53 3.77 11.30 Acceptable MAPEP 09-MaS21 41h /2009 Soil Bg/kq Co-57 572.30 586.00 410- 762 Acceptable MAPEP 09-MaS21 4h /12009 Soil Bq/kg C0-60 332.3 327.000 229-425 Acceptable MAPEP 09-MaS21 4'h 12009 Soil Bq/kg Cs-134 0
0 Acceptable MAPEP 09-MaS21 4"' 12009 Soil B,/kg Cs-137 683 669 468-870 Acceptable MAPEP 09-MaS21 41h 12009 Soil BOg/kg Fe-55 810.0 796 557-1035 Acceptable MAPEP 09-MaS21 4P! 12009 Soil Bq/kg K-40 401.3 375 263-488 Acceptable MAPEP 09-MaS21 4"h 12009 Soil Bg/kg Mn-54 834.7 796 557-1035 Acceptable MAPEP 09-MaS21 4'! 12009 Soil B/kq Ni-63 640.0 660.0 476-884 Acceptable MAPEP 09-MaS21 4h 12009 Soil Bo/kg Sr-S0.
423.30 455 319-592 -
. Acceptable MAPEP 09-MaS21 41" /2009 Soil Bq/k Zn-65 1293 1178 825-1531 Acceptable MAPEP 09-MAW21 4P" /2009 Water Bo/L Co-57 35.7 36.6 25.6-47.6 Acceptable MAPEP 09-MaW21 4"' 12009' Water BqIL Co-60 15.3 15.4 10.8 - 20.0 Acceptable MAPEP 09-MaW21 4"! 12009 Water BIL Cs-134 31.6 32.2 22.5-41.9 Acceptable MAPEP 09-MaW21 4"! 12009 Water BqIL Cs-137 40.4 41.2 28.8-53.6 Acceptable MAPEP 09-MaW21 4=, 12009 Water BO/L Mn-54 0.07 0.00 Acceptable MAPEP 09-MaW21 4" /2009 Water BOIL Ni-63 45.8 44.2 30.9-57.5 Acceptable MAPEP 09-MaW21 4" /2009 Water B /L Sr-90 16.40 12.99 9.09-16.89 Acceptable MAPEP 09-MAW21 4h /12009 Water BOL Zn-65 28.9 26.9 18.8-35.0 Acceptable MAPEP 09-RdF21 4'! 12009 Filter B.
Co-57 6.730 6.48 4.54-8.42 Acceptable MAPEP09-RdF21 4' /2009 Filter Bq Co-60 1.127 1.03 0.72-1.34 Acceptable MAPEP 09-RdF21 40 / 2009 Filter "
Bq Cs-134 0.034 0.00 Acceptable MAPEP 09-RdF21 4m /12009 Filter Bq Cs-137 1.397 1.40 0.98-1.82 Acceptable MAPEP 09-RdF21 4! /12009 Filter Bq Mn-54 5.697 5.49 3.84-7.14 Acceptable MAPEP 09-RdF21 4"N 12009 Filter Bj Sr-90 0.778 0.84 0.585 -1.086 Acceptable MAPEP 9-RdF2I 4'm /2009 Filter Bg Zn-65 4.350 3.93 2.75-5.11 Acceptable MAPEP 09-RdV21 4P / 2009 Vegetation up/sample Co-57 8.333 8.00 5.6 -10.4 Acceptabte MAPEP 09-RdV21 4Al' / 2009 Vegetation ucOsample Co-60 2.637 2.57 1.80- 3.34 Acceptable MAPEP 09-RdV21 4" / 2009 Vegetation uglsample Cs-134
-0.014 0.00 Acceptable MAPEP 09-RdV21 4P 12009 Vegetation ue/sample Cs-137 2.443 2.43 1.70-3.16 Acceptable MAPEP 09-RdV21 4' / 2009 Vegetation ue/sample Mn-54 8.407 7.90 5.5-10.3 Acceptable MAPEP 09-RdV21 41h /2009 Vegetation ugOsample Sr-90 1.577 1.78 1.25-2.31 Acceptable MAPEP 09-RdV21 4Al / 2009 Vegetation ug/sample Zn-65
-0.029 1
0.00 Acceptable GEL Laboratories in Pe'!p3'7'2 O'!"!'a'!k=2'!41' 2a4OeS,,SFad 0,he'!aoC294'7
'!a42.'!ee6!7 P$43.76&!78
,.'I~.'
53
2009 BSEP Radiological Environmental Monitoring TLD Report Comments TLD points 41 thru 74 are not ODCM TLD sample points and are not listed.
TLD sample points 19 and 80 have been retired and are not used.
All BSEP Environmental TLDs were present in 2009, except for the following TLDs:
TLD # 8 Fourth Quarter of 2009
BNP Radiological Environmental Monitoring TLD Report T
1 Dose: mR/std qtr.
TLD TLD Location Description
.1 MI E
.1 MI E 1
1.1 MI E
.1 MI E 2
0.9 MI ESE 2
0.9 MI ESE 2
0.9 MI ESE 2
0.9 MI ESE 3
0.9 MI SE 3
0.9 MI SE 3
0.9 MI SE 3
0.9 MI SE 4
1.1 MI SSE 4
1.1 MI SSE 4
1.1 MI SSE 4
1.1 MI SSE 5
1.1 MIS 5
1.1 MIS 5
1.1 MIS 5
1.1 MIS 6
1.1 MI SSW 6
1.1 MI SSW Samle *Date Dose 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 11.1 9.1 12.1 10 9.3 9.6 10.5 10.1 9.2 10.5 10.3 10.9 9
9.6 9.8 10.2 9.7 9.2 10.7 10.1 10.8 8.9 2 Sigma Error 1.2 1.1 1.2 1.1 1.8 1
0.8 1.1 1.3 1.2 0.9 1.3 1.1 0.8 1.5 1
0.9 0.8 0.8 0.9 1
1.1 Page 1 of 8
TLD 6
6 Dose.' mnR/std, qtr.
TLD Location Description 1.1 MI SSW 1.1 MI SSW Sample Date 8/15/2009 11/15/2009 7
7 7
7 1.1 MI SW 1.1 MI SW 1.1 MI SW 1.1 MI SW 1.2 MI W 8
1.2 MI W 1.2 MI W 1.0 MI WNW 1.0 MI WNW 1.0 MI WNW 1.0 MI WNW 0.8 MI NW 0.8 MI NW 0.8 MI NW 0.8 MI NW 0.9 MI NNW 0.9 MI NNW 0.9 MI NNW 0.9 MI NNW 1.1 MI N 1.1 MI N 1.1 MI N 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 Dose 10.3 9.5 9.4 9.7 10.4 10.4 9.6 2 Sigma Error 1.7 1.2 0.9 0.8 1
0.8 1.1 I
9.1 10.9 9.5 9.1 9.9 9.9 8.5 9
9.2 9.5 8.4 10.1 9.3 10.5 8.8 8.7 9.9 0.9 1.8 1.1 1.1 1.5 1.6 1
1.4 1.2 0.7 1.2 1.2 1.4 1.2 1.6 0.8 1.9 Page 2 of 8
TLD 12 13 Dose: mR/std. qtr.
TLD Location Description 1.1 MI N 1.2 MI NNE Sample Date 11/15/2009 2/15/2009 13 1.2 MI NNE 13 1.2 MI NNE 13 1.2 MI NNE 14 0.5 MI NE 0.5 MI NE 0.5 MI NE 0.5 MI NE 0.9 MI ENE 0.9 MI ENE 0.9 MI ENE 0.9 MI ENE 1.0 MI WSW 1.0 MI WSW 1.0 MI WSW 1.0 MI WSW 1.4 MI ESE 1.4 MI ESE 1.4 MI ESE 1.4 MI ESE 1.7 MI SE 1.7 MI SE 1.7 MI SE 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 Dose 9.8 9.1 8.3 10.6 9.2 8.6 10.6 9.1 10.7 10.6 2 Sigma Error 0.7 1.4 1.2 0.9 2.3 1
1.1 1
0.7 2.3 10.7 10.7 10.8 10.5 9.1 11 9.7 9.1 10 9.3 11.1 11.2 9.6 11.8 1.8 1.1 1.4 1.2 0.8 0.9 0.9 0.9 2
1.6 2.8 2.4 1.5 0.8 Page 3 of 8
Dose: lnR/std. qtr.
TLD TLD Location Description 18 1.7 MI SE 20 2.1 MI S 20 2.1 MI S 20 2.1 MI S 20 2.1 MI S 21 2.9 MI SSW 21 2.9 MI SSW 21 2.9 MI SSW 21 2.9 MI SSW 22 5.3 MI SW 22 5.3 MI SW 22 5.3 MI SW 22 5.3 MI SW 23 4.6 MI WSW 23 4.6 MI WSW 23 4.6 MI WSW 23 4.6 MI WSW Sample Date 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 Dose 10.9 12 9.3 12.1 10 10.9 11.6 11.3 11.9 11.4 9.1 12.3 9.9 9.4 7.1 9.8 7.9 2 Sigma Error 1.3 1.8 1.5 1.7 0.7 1.3 0.8 1.6 0.8 1.2 1.2 1.8 0.8 1
1.8 1.1 0.9 24 24 24 24 3.0 MI W 3.0 MI W 3.0 MI W 3.0 MI W 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 9.6 9.7 9.7 10.4 9.5 9.2 10.7 0.8 1.3 1.3 1.2 1.5 25
'8.6 MI WNW 25 8.6 MI WNW 25 8.6 MI WNW Page 4of8
TLD 25 26 26 26 26 27 27 27 27 28 28 28 28 29 29 29 29 30 30 30 30 31 31 31 Dose: inR/std. qtr.
TLD Location Description 8.6 MI WNW 5.9 MI NW 5.9 MI NW 5.9 MI NW 5.9 MI NW 5.1 MI NNW 5.1 MI NNW 5.1 MI NNW 5.1 MI NNW 4.2 MI NW 4.2 MI NW 4.2 MI NW 4.2 MI NW 2.6 MI SSW 2.6 MI SSW 2.6 MI SSW 2.6 MI SSW 2.0 MI NE 2.0 MI NE 2.0 MI NE 2.0 MI NE 2.5 MI ENE 2.5 MI ENE 2.5 MI ENE Sample Date 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 Dose 10 9.5 10.7 10.4 10.7 12 8.3 12.9 9.3 9.5 9.3 10.4 9.7 9.7 8.2 2 Sigma Error 0.7 1.3 2.1 1.4 1.7 1.1 1.3 1.1 1.1 1.4 0.9 1.4 0.8 1.1 1.1 10.5 9.1 8.9 9.8 9.5 10.1 11.8 10 12.4 0.9 0.8 1.2 1.3 1
1.3 1.5 0.9 0.8 Page 5 of 8
TLD 31 32 Dose.: mR/std. qtr.
TLD Location Description 2.5 MI ENE 5 8 MI ENE Sample Date 11/15/2009 2/1 512fl09 32 32 32 33 33 33 33 5.8 MI ENE 5.8 MI ENE 5.8 MI ENE 4.1 MI E 4.1 MI E 4.1 MI E 4.1 MI E 34 5.4 MI E 34 34 34 35 35 35 35 36 36 36 36 37 37 37 5.4 MI E 5.4 MI E 5.4 MI E 7.3 MI SSE 7.3 MI SSE 7.3 MI SSE 7.3 MI SSE 8.9 MI NE 8.9 MI NE 8.9 MI NE 8.9 MI NE 5.5 MI NW 5.5 MI NW 5.5 MI NW 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 Dose 10.7 9.2 10.6 10.4 10.9 12 8.3 11.8 8.8 9.4 2 Sigma Error 0.9 1.3 1.5 0.9 1.6 1.1 1.4 1.2 1.5 1.6 9
9.6 9.4 9.4 8.5 9.7 8.7 7.9 9.6 8.3 10.3 10.4 8.1 10.5 1.8 0.9 1.5 1
1.5 1.6 1.3 1.9 1
1.2 1.3 1.5 2.2 1.4 Page 6 of 8
Dose: inR/std, qtr.
TLD Location Description TLD Sample Date Dose 2 Sigma Error I
5.5 MI NW 11.0 MI W 11.0 MI W 11.0 MI W 11.0 MI W 5.3 MI SW 5.3 MI SW 5.3 MI SW 5.3 MI SW 6.9 MI WSW 6.9 MI WSW 6.9 MI WSW 6.9 MI WSW 4.7 MI S 4.7 MI S 4.7 MI S 4.7 MI S 4.8 MI SSW 4.8 MI SSW 4.8 MI SSW 4.8 MI SSW 5.4 MI S 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 11/15/2009 2/15/2009 5/15/2009 8/15/2009 8.5 I
8.4 9
9.1 9.9 9.3 12.7 10.4 13.7 11.2 11.9 11.8 12.9 10 10 10.6 10.3 11.6 10.4 12.8 10.7 9.5 0.9 0.8 1.3 1.3 1.9 1
1.2 1.1 1.5 1.1 1.1 0.9 1.5 2.7 0.8 1.4 1.4 1.8 1.6 1.8 1.3 1.5 1
77 5.4 MI S 77 5.4 MI S 7.2 9.5 Page 7 of 8
Dose: mnR/std, qtr.
TLD TLD Location Description Sample Date Dose 2 Sigma Error 77 5.4 MI S 11/15/2009 8.1 1
78 9.9 MI NNE 2/15/2009 8.7 1.5 78 9.9 MI NNE 5/15/2009 9
0.9 78 9.9 MI NNE 8/15/2009 9.4 1.5 78 9.9 MI NNE 11/15/2009 9.4 1
79 9.5 MI N 2/15/2009 11.1 1.4 79 9.5 MI N 5/15/2009 10.1 1.3 79 9.5 MI N 8/15/2009 12.1 1.9 79 9.5 MI N 11/15/2009 9.5 0.7 81 9.9 MI WNW-CONTROL 2/15/2009 10.9 2.3 81 9.9 MI WNW - CONTROL 5/15/2009 9.5 0.8 81 9.9 MI WNW-CONTROL 8/15/2009 12 1.2 81 9.9 MI WNW - CONTROL 11/15/2009 10.1 1.5 Page 8 of 8
2009 BSEP Radiological Environmental Monitoring Analysis Report Comments 0
Efficiency values are not included for AC samples requiring radioiodine analysis (1-131), because gamma software does not report these values.
The Less than LLD (<LLD) represents that no activity was present, but lists the LLD values.
There are no 2 sigma error values reported when activity is <LLD.
Tritium samples that exhibit activity will not indicate LLD values for the following samples:
Groundwater samples (402 - 440 and 447)
Surface Water samples (494 - 499)
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Quantity: cubic meters Activity: pCi/cubic meter Sample Point Analysis: Beta Sample Date 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200.
200 200 200 200 200 200 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/912009 2/16/2009 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 Quantity Efficiency 270.6 3.74E-01 266.9 3.74E-01 265.9 3.74E-01 264.3 3.74E-01 267.9 3.74E-01 263 3.74E-01 266.8 3.74E-01 264.7 3.74E-01 297.5 3.74E-01 293.8 3.74E-01 301.3 3.74E-01 298 3.74E-01 297.2 3.74E-01 301.8 3.74E-01 297.8 3.74E-01 299.3 3.74E-01 302.1 3.74E-01 303 3.74E-01 304.6 3.74E-01 301 3.74E-01 308.4 3.74E-01 281.3 3.74E-01 284.4 3.74E-01 285.5 3.74E-01 288.3 3.74E-01 286.2 3.74E-01 Activitýy 1.67E-02 2.08E-02 2.10E-02 2.67E-02 2.04E-02 1.76E-02 2.44E-02 2.16E-02 1.71E-02 2.66E-02 1.71E-02 1.84E-02 1.73E-02 1.38E-02 1.91E-02 2.16E-02 2.37E-02 2.08E-02 1.51E-02 1.10E-02 1.20E-02 1.37E-02 1.86E-02 1.63E-02 1.96E-02 1.99E-02 2.53E-02 2 Signma Error 3.19E-03 3.32E-03 3.43E-03 3.71 E-03 3.29E-03 3.29E-03 3.61 E-03 3.55E-03 2.96E-03 3.49E-03 2.88E-03 3.03E-03 2.95E-03 2.86E-03 3.08E-03 3.24E-03 3.30E-03 3.13E-03 2.73E-03 2.60E-03 2.61 E-03 2.78E-03 3.14E-03 3.07E-03 3.15E-03 3.20E-03 3.51E-03 LLD 3.40E-03 3.09E-03 3.35E-03 3.32E-03 3.08E-03 3.44E-03 3.39E-03 3.60E-03 2.97E-03 3.08E-03 2.76E-03 2.97E-03 2.90E-03 3.20E-03 2.99E-03 3.09E-03 3.OOE-03 2.94E-03 2.71 E-03 2.96E-03 2.89E-03 2.88E-03 3.11E-03 3.27E-03 3.02E-03 3.11E-03 3.29E-03
-.. j 200 1.0 MI WSW - VISITORS CENTER 291.5 3.74E-01 Page 1 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Analysis. Beta Quantily: cubic meters ActivitY: pCi/cubic meter Sample.Point Samnple Date Quantity Efficiency Activity 2 Signia Error LLD 200 1.0 MI WSW-VISITORS CENTER 7/13/2009 285 3.74E-01 1.76E-02 3.13E-03 3.22E-03 200 1.0 MI WSW - VISITORS CENTER 7/20/2009 289.4 3.74E-01 2.30E-02 3.41 E-03 3.29E-03 200 1.0 MI WSW - VISITORS CENTER 7/27/2009 284.1 3.68E-01 2.13E-02 3.36E-03 3.26E-03 200 1.0 MI WSW - VISITORS CENTER 8/3/2009 292 3.68E-01 1.18E-02 2.93E-03 3.54E-03 200 1.0 MI WSW - VISITORS CENTER 8/10/2009 281 3.68E-01 2.OOE-02 3.34E-03 3.37E-03 200 1.0 MI WSW - VISITORS CENTER 8/17/2009 285.6 3.68E-01 2.07E-02 3.31 E-03 3.22E-03 200 1.0 MI WSW - VISITORS CENTER 8/24/2009 284.5 3.68E-01 1.28E-02 2.93E-03 3.35E-03 200 1.0 MI WSW-VISITORS CENTER 8/31/2009 284.4 3.68E-01 1.59E-02 3.04E-03 3.18E-03 200 1.0 MI WSW - VISITORS CENTER 9/7/2009 281.4 3.68E-01 1.80E-02 3.18E-03 3.22E-03 200 1.0 MI WSW-VISITORS CENTER 9/14/2009 284.4 3.68E-01 1.54E-02 3.04E-03 3.26E-03 200 1.0 MI WSW-VISITORS CENTER 9/21/2009 282.2 3.68E-01 2.43E-02 3.51 E-03 3.26E-03 200 1.0 MI WSW-VISITORS CENTER 9/28/2009 286 3.68E-01 1.06E-02 2.74E-03 3.24E-03 200 1.0 MI WSW - VISITORS CENTER 10/5/2009 273.6 3.68E-01 2.13E-02 3.38E-03 3.20E-03 200 1.0 MI WSW - VISITORS CENTER 10/12/2009 280.9 3.68E-01 1.57E-02 3.12E-03 3.40E-03 200 1.0 MI WSW - VISITORS CENTER 10/19/2009 273.2 3.68E-01 1.25E-02 3.01 E-03 3.54E-03 200 1.0 MI WSW-VISITORS CENTER 10/26/2009 275.1 3.68E-01 1.96E-02 3.40E-03 3.52E-03 200 1.0 MI WSW-VISITORS CENTER 11/2/2009 279.2 3.68E-01 8.33E-03 2.61 E-03 3.24E-03 200 1.0 MI WSW-VISITORS CENTER 11/9/2009 273.6 3.68E-01 2.55E-02 3.72E-03 3.56E-03 200 1.0 MI WSW-VISITORS CENTER 11/16/2009 272.1 3.68E-01 1.01E-02 2.80E-03 3.38E-03 200 1.0 MI WSW-VISITORS CENTER 11/23/2009 272.9 3.68E-01 2.22E-02 3.46E-03 3.29E-03 200 1.0 MI WSW-VISITORS CENTER 11/30/2009 271.3 3.68E-01 2.07E-02 3.33E-03 3.15E-03 200 1.0 MI WSW-VISITORS CENTER 12/7/2009 270.8 3.68E-01 1.49E-02 3.14E-03 3.47E-03 200 1.0 MI WSW - VISITORS CENTER 12/14/2009 261.6 3.68E-01 2.21E-02 3.59E-03 3.54E-03 200 1.0 MI WSW - VISITORS CENTER 12/21/2009 270.6 3.68E-01 2.07E-02 3.33E-03 3.13E-03 200 1.0 MI WSW - VISITORS CENTER 12/28/2009 271.4 3.68E-01 2.48E-02 3.60E-03 3.31 E-03 201 0.5 MI NE - PMAC 1/5/2009 286 3.74E-01 1.70E-02 3.09E-03 3.21E-03 201 0.5 MI NE - PMAC 1/12/2009 282.4 3.74E-01 2.OOE-02 3.15E-03 2.92E-03 Page 2 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: A ir Particulate Quantity: cubic meters Activiy: pCi/cubic meter Sample Point Analysis: Beta Samnle Date 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE-PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 1/19/2009 1/26/2009 2/2/2009 2/9/2009 2/16/2009 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 7/13/2009 7/20/2009 Quantity Efieiency 277.5 3.74E-01 278 3.74E-01 282.6 3.74E-01 276.4 3.74E-01 289.4 3.74E-01 269.2 3.74E-01 277.8 3.74E-01 278.2 3.74E-01 278.3 3.74E-01 286 3.74E-01 283.3 3.74E-01 285.9 3.74E-01 282.7 3.74E-01 283.6 3.74E-01 285.4 3.74E-01 287 3.74E-01 287.3 3.74E-01 289 3.74E-01 294 3.74E-01 281.8 3.74E-01 289.4 3.74E-01 288.3 3.74E-01 290.8 3.74E-01 288.5 3.74E-01 292.6 3.74E-01 286 3.74E-01 291.2 3.74E-01 Activity 2.43E-02 2.56E-02 1.96E-02 2.14E-02 2.69E-02 2.14E-02 1.82E-02 2.45E-02 1.66E-02 1.87E-02 1.97E-02 1.27E-02 1.61E-02 1.79E-02 2.26E-02 2.38E-02 1.68E-02 1.06E-02 1.24E-02 1.38E-02 1.98E-02 1.65E-02 2.13E-02 1.85E-02 2.60E-02 1.74E-02 1.94E-02 2 Signma Error 3.50E-03 3.54E-03 3.13E-03 3.38E-03 3.54E-03 3.50E-03 3.17E-03 3.52E-03 3.01 E-03 3.13E-03 3.18E-03 2.91 E-03 3.02E-03 3.16E-03 3.37E-03 3.40E-03 2.94E-03 2.65E-03 2.73E-03 2.78E-03 3.17E-03 3.06E-03 3.22E-03 3.12E-03 3.54E-03 3.11E-03 3.22E-03 LLD 3.21 E-03 3.15E-03 2.92E-03 3.27E-03 3.13E-03 3.54E-03 3.18E-03 3.25E-03 2.99E-03 3.09E-03 3.04E-03 3.38E-03 3.15E-03 3.26E-03 3.17E-03 3.10E-03 2.87E-03 3.08E-03 3.03E-03 2.87E-03 3.05E-03 3.23E-03 2.99E-03 3.09E-03 3.28E-03 3.21 E-03 3.27E-03 Page 3 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Analysis: Beta Quantity: cubic meters Activity: pCi/cubic meter Sample Point Sample Date Quantity Efficiency Activity 2 Signma Error LLD 201 0.5 MI NE - PMAC 7/27/2009 285.5 3.68E-01 2.23E-02 3.40E-03 3.25E-03 201 0.5 MI NE - PMAC 8/3/2009 291.5 3.68E-01 1.25E-02 2.97E-03 3.54E-03 201 0.5 MI NE - PMAC 8/10/2009 284.2 3.68E-01 2.18E-02 3.41 E-03 3.33E-03 201 0.5 MI NE - PMAC 8/17/2009 255.8 3.68E-01 1.92E-02 3.48E-03 3.60E-03 201 0.5 MI NE - PMAC 8/24/2009 284.6 3.68E-01 1.64E-02 3.13E-03 3.35E-03 201 0.5 MI NE - PMAC 8/31/2009 284.4 3.68E-01 1.73E-02 3.11E-03 3.18E-03 201 0.5 MI NE-PMAC 9/7/2009 283.5 3.68E-01 1.96E-02 3.24E-03 3.19E-03 201 0.5 MI NE - PMAC 9/14/2009 284.6 3.68E-01 1.54E-02 3.03E-03 3.26E-03 201 0.5 MI NE - PMAC 9/21/2009 282.6 3.68E-01 2.60E-02 3.59E-03 3.25E-03 201 0.5 MI NE - PMAC 9/28/2009 285.9 3.68E-01 9.85E-03 2.69E-03 3.24E-03 201 0.5 MI NE - PMAC 10/5/2009 276.5 3.68E-01 2.05E-02 3.31 E-03 3.17E-03 201 0.5 MI NE - PMAC 10/12/2009 274 3.68E-01 1.67E-02 3.23E-03 3.48E-03 201 0.5 MI NE - PMAC 10/19/2009 275.9 3.68E-01 1.31E-02 3.03E-03 3.51 E-03 201 0.5 MI NE - PMAC 10/26/2009 276.3 3.68E-01 1.85E-02 3.33E-03 3.50E-03 201 0.5 MI NE - PMAC 11/2/2009 280.3 3.68E-01 9.08E-03 2.65E-03 3.23E-03 201 0.5 MI NE - PMAC 11/9/2009 275.6 3.68E-01 2.77E-02 3.80E-03 3.54E-03 201 0.5 MI NE - PMAC 11/16/2009 276.5 3.68E-01 9.39E-03 2.72E-03 3.33E-03 201 0.5 MI NE - PMAC 11/23/2009 277.4 3.68E-01 2.15E-02 3.39E-03 3.24E-03 201 0.5 MI NE - PMAC 11/30/2009 273 3.68E-01 1.79E-02 3.17E-03 3.13E-03 201 0.5 MI NE - PMAC 12/7/2009 274.2 3.68E-01 1.26E-02 2.97E-03 3.43E-03 201 0.5 MI NE - PMAC 12/14/2009 272.3 3.68E-01 1.99E-02 3.38E-03 3.40E-03 201 0.5 MI NE - PMAC 12/21/2009 271.4 3.68E-01 1.94E-02 3.25E-03 3.12E-03 201 0.5 MI NE - PMAC 12/28/2009 272.4 3.68E-01 2.44E-02 3.57E-03 3.30E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 1/5/2009 274.1 3.74E-01 2.08E-02 3.39E-03 3.35E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 1/1212009 270.8 3.74E-01 1.95E-02 3.22E-03 3.05E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 1/19/2009 269.9 3.74E-01 2.65E-02 3.67E-03 3.30E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 1/26/2009 268.1 3.74E-01 3.25E-02 3.95E-03 3.27E-03 Page 4 of 13
BSEP Radiological Environmental Monitoring Analysis Report M'edia Type: Air Particulate Analysis: Beta Quantity: cubic meters Activity: pCi/cubic meter Sample Point Sample Date Quantity Efficiency Activity 2 Sigma Error LLD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 2/2/2009 272.1 3.74E-01 2.40E-02 3.45E-03 3.03E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 2/9/2009 267.2 3.74E-01 2.03E-02 3.40E-03 3.39E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 2/16/2009 271.7 3.74E-01 2.30E-02 3.50E-03 3.33E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 2/23/2009 269.5 3.74E-01 2.25E-02 3.56E-03 3.53E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 3/2/2009 271 3.74E-01 1.67E-02 3.14E-03 3.26E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 3/9/2009 266.2 3.74E-01 3.22E-02 3.99E-03 3.40E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 3/16/2009 273.7 3.74E-01 1.97E-02 3.22E-03 3.04E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 3/23/2009 271.3 3.74E-01 2.12E-02 3.38E-03 3.26E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 3/30/2009 272.6 3.74E-01 2.07E-02 3.32E-03 3.16E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 4/6/2009 275.2 3.74E-01 1.51 E-02 3.13E-03 3.51 E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 4/13/2009 269.8 3.74E-01 2.22E-02 3.46E-03 3.30E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 4/20/2009 271.4 3.74E-01 2.19E-02 3.47E-03 3.41E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 4/27/2009 274.5 3.74E-01 2.36E-02 3.51 E-03 3.30E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 5/4/2009 277.2 3.74E-01 2.55E-02 3.56E-03 3.21 E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 5/11/2009 277.4 3.74E-01 1.78E-02 3.07E-03 2.97E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 5/18/2009 277.4 3.74E-01 1.15E-02 2.79E-03 3.21E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 5/25/2009 282.3 3.74E-01 1.40E-02 2.91E-03 3.16E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 6/1/2009 277.3 3.74E-01 1.40E-02 2.83E-03 2.92E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 6/8/2009 286.1 3.74E-01 1.85E-02 3.12E-03 3.09E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 6/15/2009 284.4 3.74E-01 1.75E-02 3.15E-03 3.28E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 6/22/2009 286.2 3.74E-01 1.94E-02 3.15E-03 3.04E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 6/29/2009 283.8 3.74E-01 1.80E-02 3.12E-03 3.14E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 7/6/2009 287.5 3.74E-01 2.50E-02 3.53E-03 3.34E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 7/13/2009 280.7 3.74E-01 1.37E-02 2.94E-03 3.27E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 7/20/2009 284.4 3.74E-01 2.60E-02 3.60E-03 3.35E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 7/27/2009 278.1 3.68E-01 1.79E-02 3.22E-03 3.33E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 8/3/2009 280.3 3.68E-01 1.26E-02 3.07E-03 3.69E-03 Page 5 of 13
BSEP Radiological Environmental Monitoring Analysis Report AMedia Type: Air Particulate Analysis: Beta Quantity: cubic meters Activitv: pCi/cubic meter Sample Point Sample.Date Quantity Eficiency Activity 2 Sigma Error LLD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 8/10/2009 271.5 3.68E-01 2.03E-02 3.44E-03 3.49E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 8/17/2009 274.9 3.68E-01 2.09E-02 3.40E-03 3.35E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 8/24/2009 275.4 3.68E-01 1.32E-02 3.02E-03 3.47E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 8/31/2009 275.2 3.68E-01 1.56E-02 3.09E-03 3.29E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 9/7/2009 273.5 3.68E-01 1.77E-02 3.22E-03 3.31 E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 9/14/2009 274.6 3.68E-01 1.53E-02 3.11E-03 3.38E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 9/21/2009 273.8 3.68E-01 2.50E-02 3.62E-03 3.36E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 9/28/2009 277.3 3.68E-01 9.53E-03 2.74E-03 3.34E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 10/5/2009 266.3 3.68E-01 2.06E-02 3.40E-03 3.29E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 10/12/2009 267.7 3.68E-01 1.49E-02 3.18E-03 3.57E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 10/19/2009 266.7 3.68E-01 1.29E-02 3.09E-03 3.63E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 10/26/2009 266 3.68E-01 1.93E-02 3.46E-03 3.64E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 11/2/2009 270.2 3.68E-01 8.43E-03 2.68E-03 3.35E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 11/9/2009 263.9 3.68E-01 2.37E-02 3.72E-03 3.69E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 11/16/2009 264.5 3.68E-01 8.33E-03 2.75E-03 3.48E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 11/23/2009 261.7 3.68E-01 1.93E-02 3.40E-03 3.43E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 11/30/2009 257.3 3.68E-01 2.02E-02 3.43E-03 3.32E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 12/7/2009 250.8 3.68E-01 9.76E-03 3.OOE-03 3.75E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 12/14/2009 247.5 3.68E-01 1.91 E-02 3.57E-03 3.74E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 12/21/2009 297 3.68E-01 2.18E-02 3.19E-03 2.85E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION R 12/28/2009 296 3.68E-01 2.24E-02 3.29E-03 3.03E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 1/5/2009 285.9 3.74E-01 1.89E-02 3.19E-03 3.21E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 1/12/2009 282.1 3.74E-01 1.86E-02 3.08E-03 2.92E-03 203 2.0 M I SSW - SOUTHPORT SUBSTATION 1/19/2009 277.5 3.74E-01 2.47E-02 3.52E-03 3.21 E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 1/26/2009 277.1 3.74E-01 2.44E-02 3.49E-03 3.16E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2/2/2009 283.5 3.74E-01 2.04E-02 3.17E-03 2.91E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2/9/2009 274.2 3.74E-01 2.10E-02 3.38E-03 3.30E-03 Page 6 of 13
BSEP Radiological Environmental Monitoring Analysis Report M'edia Type: Air Particulate Analvsis Beta Quantity: cubic meters ActivitY: pCi/cubic me/er Sample.Point Sample Date Quantity E'ficiency
- Activit, 2 Sigma Error LLD 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2/16/2009 283.1 3.74E-01 2.01E-02 3.26E-03 3.20E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2/23/2009 278.5 3.74E-01 2.17E-02 3.44E-03 3.42E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 3/2/2009 280.5 3.74E-01 1.86E-02 3.17E-03 3.15E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 3/9/2009 275.7 3.74E-01 2.83E-02 3.72E-03 3.28E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 3/16/2009 285.9 3.74E-01 2.22E-02 3.26E-03 2.91 E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 3/23/2009 284.4 3.74E-01 1.71 E-02 3.06E-03 3.11E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 3/30/2009 283.9 3.74E-01 1.96E-02 3.17E-03 3.04E-03 203 2.0 M I SSW - SOUTHPORT SUBSTATION 4/6/2009 287.9 3.74E-01 1.69E-02 3.13E-03 3.35E-03 203 2.0 M I SSW - SOUTHPORT SUBSTATION 4/13/2009 282 3.74E-01 1.71E-02 3.08E-03 3.16E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 4/20/2009 284.6 3.74E-01 1.65E-02 3.08E-03 3.25E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 4/27/2009 288.3 3.74E-01 2.36E-02 3.40E-03 3.14E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 5/4/2009 289.4 3.74E-01 2.05E-02 3.21 E-03 3.08E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 5/11/2009 288.9 3.74E-01 1.77E-02 2.98E-03 2.86E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 5/18/2009 288.3 3.74E-01 1.08E-02 2.67E-03 3.09E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 5/25/2009 293.8 3.74E-01 1.03E-02 2.60E-03 3.03E-03 203 2.0 MI SSW-SOUTHPORT SUBSTATION 6/1/2009 281.3 3.74E-01 1.28E-02 2.72E-03 2.88E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 6/8/2009 261.8 3.74E-01 1.79E-02 3.29E-03 3.38E-03 203 2.0 MI SSW-SOUTHPORT SUBSTATION 6/15/2009 276.9 3.74E-01 1.67E-02 3.16E-03 3.37E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 6/22/2009 282.1 3.74E-01 1.81E-02 3.11E-03 3.08E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 6/29/2009 281.6 3.74E-01 2.11E-02 3.30E-03 3.16E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 7/6/2009 288 3.74E-01 2.58E-02 3.56E-03 3.33E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 7/13/2009 283.7 3.74E-01 1.73E-02 3.12E-03 3.24E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 7/20/2009 290.2 3.74E-01 2.43E-02 3.47E-03 3.28E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 7/27/2009 285.8 3.68E-01 2.25E-02 3.40E-03 3.24E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 8/3/2009 293.8 3.68E-01 1.40E-02 3.04E-03 3.52E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 8/10/2009 287.5 3.68E-01 2.25E-02 3.41E-03 3.30E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 8/17/2009 294 3.68E-01 2.12E-02 3.27E-03 3.13E-03 Page 7 of 13
.BSEP Radiological Environmental Monitoring Analysis Report Aleedia Type: Air Particulate
-Analvsis. Beta Quantit.: cubic meters Activity: pCiicubic meter Sample Point Sample Date Quantity Efficiency Activity 2 Sigma Error LLD 203 2.0 MI SSW - SOUTHPORT SUBSTATION 8/24/2009 295.3 3.68E-01 1.52E-02 2.98E-03 3.23E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 8/31/2009 296.1 3.68E-01 1.31 E-02 2.79E-03 3.06E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 9/7/2009 294.9 3.68E-01 1.98E-02 3.17E-03 3.07E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 9/14/2009 297 3.68E-01 1.45E-02 2.89E-03 3.12E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 9/21/2009 296.3 3.68E-01 2.60E-02 3.49E-03 3.10E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 9/28/2009 301.2 3.68E-01 1,12E-02 2.67E-03 3.08E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 10/5/2009 287.7 3.68E-01 2.36E-02 3.38E-03 3.05E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 10/12/2009 298.3 3.68E-01 1.72E-02 3.07E-03 3.20E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 10/19/2009 290 3.68E-01 1.25E-02 2.89E-03 3.34E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 10/26/2009 291 3.68E-01 1.77E-02 3.17E-03 3.33E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/2/2009 295.8 3.68E-01 9.02E-03 2.54E-03 3.06E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/9/2009 291.2 3.68E-01 2.61E-02 3.59E-03 3.35E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/16/2009 293 3.68E-01 9.94E-03 2.64E-03 3.14E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/23/2009 291.3 3.68E-01 2.55E-02 3.48E-03 3.08E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/30/2009 288.1 3.68E-01 1.88E-02 3.10E-03 2.96E-03 203 2.0 MI SSW-SOUTHPORT SUBSTATION 12/7/2009 288.5 3.68E-01 1.28E-02 2.88E-03 3.26E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/14/2009 286.8 3.68E-01 2.24E-02 3.39E-03 3.23E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/21/2009 286.7 3.68E-01 1.90E-02 3.12E-03 2.95E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/28/2009 286.4 3.68E-01 2.51E-02 3.50E-03 3.14E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/5/2009 296.7 3.74E-01 2,34E-02 3.34E-03 3.10E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/12/2009 296.9 3.74E-01 1.96E-02 3.03E-03 2.78E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/19/2009 290.3 3.74E-01 2.53E-02 3.45E-03 3.07E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/26/2009 287 3.74E-01 2.50E-02 3.44E-03 3.05E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/2/2009 288.6 3.74E-01 2.20E-02 3.22E-03 2.86E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/9/2009 281 3.74E-01 1.45E-02 2.96E-03 3.22E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 284.7 3.74E-01 2.47E-02 3.48E-03 3.18E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/23/2009 280.3 3.74E-01 1.90E-02 3.28E-03 3.40E-03 Page 8 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Analysis: Beta Quantity: cubic meters Activi:Y." pCi/cubic meter Sample Point Sample Date Quantity Eqfieiency Activity 2 Sigma Error LLD 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/2/2009 282.2 3.74E-01 1.77E-02 3.11E-03 3.13E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/9/2009 279 3.74E-01 2.69E-02 3.63E-03 3.24E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/16/2009 285.1 3.74E-01 1.84E-02 3.06E-03 2.92E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/23/2009 283 3.74E-01 1.54E-02 2.97E-03 3.12E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/30/2009 283.4 3.74E-01 1.56E-02 2.95E-03 3.04E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 4/6/2009 284.6 3.74E-01 1.31E-02 2.95E-03 3.39E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 4/13/2009 281 3.74E-01 2.01 E-02 3.25E-03 3.17E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 4/20/2009 280.1 3.74E-01 1.85E-02 3.22E-03 3.30E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 4/27/2009 280.9 3.74E-01 1.90E-02 3.21 E-03 3.22E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/4/2009 279.9 3.74E-01 2.30E-02 3.41 E-03 3.18E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/11/2009 281.8 3.74E-01 1.63E-02 2.96E-03 2.93E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/18/2009 278.7 3.74E-01 1.11 E-02 2.75E-03 3.20E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/25/2009 276.9 3.74E-01 1.34E-02 2.91 E-03 3.22E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 6/1/2009 287 3.74E-01 1.26E-02 2.68E-03 2.82E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 6/8/2009 284.6 3.74E-01 1.68E-02 3.04E-03 3.11E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 6/15/2009 287.4 3.74E-01 1.49E-02 2.98E-03 3.24E-03 204 22.4MI NNE - SUTTON PLANT (CONTROL) 6/22/2009 287.4 3.74E-01 1.98E-02 3.16E-03 3.03E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 6/29/2009 287.5 3.74E-01 1.52E-02 2.94E-03 3.10E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 7/6/2009 291.2 3.74E-01 2.63E-02 3.56E-03 3.29E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 7/13/2009 283.8 3.74E-01 1.79E-02 3.15E-03 3.24E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 7/20/2009 286.7 3.74E-01 1.94E-02 3.25E-03 3.32E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 7/27/2009 288.2 3.68E-01 2.10E-02 3.31E-03 3.22E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/3/2009 286.8 3.68E-01 1.60E-02 3.20E-03 3.60E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/10/2009 288 3.68E-01 2.10E-02 3.34E-03 3.29E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 286.5 3.68E-01 2.14E-02 3.34E-03 3.21E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/24/2009 287.8 3.68E-01 1.20E-02 2.85E-03 3.32E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/3112009 287.8 3.68E-01 1.54E-02 2.98E-03 3.15E-03 Page 9 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Quantity: cubic meters Activit,: pCi/cubic meter Sample Point Analysis: Beta 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 205 205 205 205 205 205 205 205 205 205 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE-- SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND Sample Date 9/7/2009 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 11/9/2009 11/16/2009 11/23/2009 11/30/2009 12/7/2009 12/14/2009 12/21/2009 12/28/2009 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/9/2009 2/16/2009 2/23/2009 3/2/2009 3/9/2009 Quantity 283.9 283.1 286.1 285.5 284.1 284 281.6 278.2 283.9 278.9 279.1 283.1 274.2 276.8 275.9 276.2 275.2 294 291.7 283.9 282 288 282.9 290 278.4 286.3 276.8 Eýfficiency 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.68E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 3.74E-01 Activity 2.24E-02 1.67E-02 2.47E-02 1.02E-02 2.18E-02 1.34E-02 1.49E-02 1.80E-02 7.76E-03 2.65E-02 9.56E-03 2.14E-02 1.69E-02 1.16E-02 2.33E-02 2.OOE-02 2.08E-02 2.03E-02 2.15E-02 2.62E-02 2.66E-02 1.93E-02 2.40E-02 2.51 E-02 2.56E-02 1.83E-02 3.04E-02 2 Sigma Error 3.39E-03 3.12E-03 3.50E-03 2.72E-03 3.32E-03 2.97E-03 3.09E-03 3.29E-03 2.53E-03 3.72E-03 2.71 E-03 3.34E-03 3.10E-03 2.89E-03 3.53E-03 3.25E-03 3.37E-03 3.20E-03 3.17E-03 3.54E-03 3.55E-03 3.08E-03 3.46E-03 3.45E-03 3.63E-03 3.11E-03 3.81 E-03 LLD 3.19E-03 3.27E-03 3.21 E-03 3.25E-03 3.08E-03 3.36E-03 3.44E-03 3.48E-03 3.19E-03 3.49E-03 3.30E-03 3.17E-03 3.11E-03 3.40E-03 3.36E-03 3.06E-03 3.26E-03 3.13E-03 2.83E-03 3.14E-03 3.11E-03 2.86E-03 3.20E-03 3.12E-03 3.42E-03 3.09E-03 3.27E-03 Page 10 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Particulate Analysis. Beta Quantity: cubic meters Activiy:: pCi/cubic meter Sample Point Sample Date Quantity Efficiency
- Activit, 2 Sigma Error LLD 205 0.6 MI SSE - SPOIL POND 3/16/2009 300.6 3.74E-01 2.08E-02 3.08E-03 2.77E-03 205 0.6 MI SSE - SPOIL POND 3/23/2009 289.7 3.74E-01 2.01E-02 3.18E-03 3.05E-03 205 0.6 MI SSE - SPOIL POND 3/30/2009 293.8 3.74E-01 1.74E-02 2.98E-03 2.93E-03 205 0.6 MI SSE - SPOIL POND 4/6/2009 304.2 3.74E-01 1.35E-02 2.83E-03 3.17E-03 205 0.6 MI SSE - SPOIL POND 4/13/2009 292.2 3.74E-01 1.81 E-02 3.06E-03 3.05E-03 205 0.6 MI SSE - SPOIL POND 4/20/2009 293.9 3.74E-01 2.15E-02 3.27E-03 3.15E-03 205 0.6 MI SSE - SPOIL POND 4/27/2009 306.3 3.74E-01 2.52E-02 3.34E-03 2.95E-03 205 0.6 M I SSE - SPOIL POND 5/4/2009 307.7 3.74E-01 2.22E-02 3.17E-03 2.90E-03 205 0.6 MI SSE - SPOIL POND 5/11/2009 308.7 3.74E-01 1.56E-02 2.74E-03 2.67E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 306 3.74E-01 9.84E-03 2.49E-03 2.91E-03 205 0.6 MI SSE - SPOIL POND 5/25/2009 311.8 3.74E-01 1.17E-02 2.57E-03 2.86E-03 205 0.6 MI SSE - SPOIL POND 6/1/2009 278 3.74E-01 1.33E-02 2.78E-03 2.91 E-03 205 0.6 MI SSE - SPOIL POND 6/8/2009 285.4 3.74E-01 1.68E-02 3.03E-03 3.10E-03 205 0.6 MI SSE - SPOIL POND 6/15/2009 283.6 3.74E-01 1.63E-02 3.09E-03 3.29E-03 205 0.6 MI SSE - SPOIL POND 6/22/2009 282.7 3.74E-01 2.31 E-02 3.37E-03 3.08E-03 205 0.6 MI SSE - SPOIL POND 6/29/2009 281.1 3.74E-01 1.84E-02 3.16E-03 3.17E-03.
205 0.6 MI SSE - SPOIL POND 7/6/2009 284.8 3.74E-01 2.55E-02 3.58E-03 3.37E-03 205 0.6 MI SSE - SPOIL POND 7/13/2009 276.3 3.74E-01 1.28E-02 2.92E-03 3.33E-03 205 0.6 MI SSE - SPOIL POND 7/20/2009 283 3.74E-01 2.37E-02 3.50E-03 3.37E-03 205 0.6 MI SSE - SPOIL POND 7/27/2009 279.7 3.68E-01 2.21E-02 3.43E-03 3.31 E-03 205 0.6 MI SSE - SPOIL POND 8/3/2009 286.7 3.68E-01 1.50E-02 3.15E-03 3.60E-03 205 0.6 MI SSE - SPOIL POND 8/10/2009 278.3 3.68E-01 1.97E-02 3.35E-03 3.41E-03 205 0.6 MI SSE - SPOIL POND 8/17/2009 281.6 3.68E-01 2.03E-02 3.31 E-03 3.27E-03 205 0.6 MI SSE - SPOIL POND 8/24/2009 282.6 3.68E-01 1.27E-02 2.94E-03 3.38E-03 205 0.6 MI SSE - SPOIL POND 8/31/2009 282.6 3.68E-01 1.35E-02 2.91 E-03 3.20E-03 205 0.6 MI SSE - SPOIL POND 9/7/2009 279 3.68E-01 1.85E-02 3.22E-03 3.25E-03 205 0.6 MI SSE - SPOIL POND 9/14/2009 281.7 3.68E-01 1.23E-02 2.88E-03 3.29E-03 Page II ofJ13
BSEP Radiological Environmental Monitoring Analysis Report Media 7Tvpe: Air Particulate Analysis: Beta Quantity: cubic meters Activity: pCi/cubic meter Sanmple Point Sample Date Quantity Eqficiency
- Activit, 2 Sigma Error LLD 205 0.6 MI SSE - SPOIL POND 9/21/2009 281 3.68E-01 2.59E-02 3.60E-03 3.27E-03 205 0.6 MI SSE - SPOIL POND 9/28/2009 286.5 3.68E-01 9.66E-03 2.67E-03 3.23E-03 205 0.6 MI SSE - SPOIL POND 10/5/2009 275.1 3.68E-01 2.17E-02 3.39E-03 3.19E-03 205 0.6 MI SSE - SPOIL POND 10/12/2009 282.7 3.68E-01 1.58E-02 3.11E-03 3.38E-03 205 0.6 MI SSE - SPOIL POND 10/19/2009 274.6 3.68E-01 1.41E-02 3.10E-03 3.53E-03 205 0.6 MI SSE - SPOIL POND 10/26/2009 277 3.68E-01 1.92E-02 3.36E-03 3.49E-03 205 0.6 MI SSE - SPOIL POND 11/2/2009 283.4 3.68E-01 9.42E-03 2.65E-03 3.20E-03 205 0.6 MI SSE - SPOIL POND 11/9/2009 275.4 3.68E-01 2.45E-02 3.65E-03 3.54E-03 205 0.6 MI SSE - SPOIL POND 11/16/2009 278.4 3.68E-01 8.88E-03 2.67E-03 3.30E-03 205 0.6 MI SSE - SPOIL POND 11/23/2009 275.4 3.68E-01 1.99E-02 3.32E-03 3.26E-03 205 0.6 MI SSE - SPOIL POND 11/30/2009 273.5 3.68E-01 1.83E-02 3.19E-03 3.12E-03 205 0.6 MI SSE - SPOIL POND 12/7/2009 274.6 3.68E-01 1.15E-02 2.90E-03 3.43E-03 205 0.6 MI SSE - SPOIL POND 12/14/2009 272.8 3.68E-01 2.OOE-02 3.38E-03 3.40E-03 205 0.6 MI SSE - SPOIL POND 12/21/2009 272.8 3.68E-01 2.02E-02 3.29E-03 3.10E-03 205 0.6 MI SSE - SPOIL POND 12/28/2009 273.3 3.68E-01 2.19E-02 3.44E-03 3.29E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 4/13/2009 283.7 3.74E-01 1.84E-02 3.15E-03 3.14E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 4/20/2009 285.4 3.74E-01 2.18E-02 3.35E-03 3.24E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 4/27/2009 286.2 3.74E-01 2.48E-02 3.47E-03 3.16E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 5/4/2009 285.5 3.74E-01 2.36E-02 3.40E-03 3.12E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 5/11/2009 288.1 3.74E-01 2.08E-02 3.16E-03 2.86E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 5/18/2009 284.8 3.74E-01 1.01 E-02 2.65E-03 3.13E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 5/25/2009 284.9 3.74E-01 1.58E-02 2.99E-03 3.13E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 6/1/2009 284.8 3.74E-01 1.52E-02 2.85E-03 2.84E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 6/8/2009 283.3 3.74E-01 2.13E-02 3.29E-03 3.12E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 6/15/2009 285.2 3.74E-01 1.64E-02 3.08E-03 3.27E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 6/22/2009 285.1 3.74E-01 2.05E-02 3.22E-03 3.05E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 6/29/2009 285.7 3.74E-01 1.69E-02 3.04E-03 3.12E-03 Page 12 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Tvpe: Air Particulate Analysis: Beta Quantity: cubic meters Activity: pCi/cubic meter Sample Point Sample Date Quantity Efficiency Activit 2 Sigma Error LLD 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 7/6/2009 288.2 3.74E-01 2.72E-02 3.63E-03 3.33E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 7/13/2009 281.4 3.74E-01 2.01E-02 3.29E-03 3.27E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 7/20/2009 284.4 3.74E-01 1.97E-02 3.28E-03 3.35E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 7/27/2009 285.1 3.68E-01 2.06E-02 3.31E-03 3.25E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 8/3/2009 283.8 3.68E-01 1.60E-02 3.23E-03 3.64E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 8/10/2009 282.7 3.68E-01 2.39E-02 3.52E-03 3.35E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 8/17/2009 280.8 3.68E-01 2.14E-02 3.38E-03 3.28E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 8/24/2009 281.7 3.68E-01 1.90E-02 3.29E-03 3.39E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 8/31/2009 280.8 3.68E-01 1.55E-02 3.04E-03 3.22E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 9/7/2009 278.4 3.68E-01 2.34E-02 3.48E-03 3.25E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 9/14/2009 279.9 3.68E-01 1.88E-02 3.26E-03 3.31E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 9/21/2009 279 3.68E-01 2.90E-02 3.76E-03 3.30E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 9/28/2009 279.5 3.68E-01 1.16E-02 2.85E-03 3.32E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 10/5/2009 278.7 3.68E-01 2.33E-02 3.44E-03 3.14E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 10/12/2009 278.6 3.68E-01 1.70E-02 3.21E-03 3.43E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 10/19/2009 277.3 3.68E-01 1.48E-02 3.12E-03 3.49E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 10/26/2009 271.6 3.68E-01 2.19E-02 3.55E-03 3.56E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 11/2/2009 278.3 3.68E-01 1.06E-02 2.76E-03 3.25E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 11/9/2009 272.6 3.68E-01 2.65E-02 3.77E-03 3.58E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 11/16/2009 273.7 3.68E-01 1.29E-02 2.96E-03 3.36E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 11/23/2009 277.4 3.68E-01 2.07E-02 3.34E-03 3.24E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 11/30/2009 269.2 3.68E-01 2.15E-02 3.39E-03 3.17E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 12/7/2009 272.2 3.68E-01 1.23E-02 2.97E-03 3.46E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 12/14/2009 271.9 3.68E-01 2.13E-02 3.46E-03 3.41E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 12/21/2009 272.9 3.68E-01 2.15E-02 3.36E-03 3.10E-03 206 11.3 MILES NW FROM PLANT AT BRUNSWICK 12/28/2009 270.8 3.68E-01 2.48E-02 3.61E-03 3.32E-03 Page 13 of 13
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activitv: pCi/cubic meter Sample Point 200 200 200 200 200 200 200 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER Sample Date 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/9/2009 2/16/2009 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW -VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 5/25/2009 6/1/2009 Quantity 270.6 266.9 265.9 264.3 267.9 263.0 266.8 264.7 297.5 293.8 301.3 298.0 297.2 301.8 297.8 299.3 302.1 303.0 304.6 301.0 308.4 281.3 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 3.05E-02 2.46E-02 2.30E-02 2.31 E-02 2.37E-02 2.98E-02 2.30E-02 2.48E-02 2.13E-02 2.30E-02 1.79E-02 2.02E-02 2.24E-02 2.21 E-02 2.03E-02 2.01E-02 1.76E-02 1.95E-02 1.98E-02 1.51E-02 1.85E-02 1.93E-02 Page 1 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activit': pCi/cubic meter Sample Point 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER
'1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER Sample Date 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 7/13/2009 7/20/2009 7/27/2009 8/3/2009 8/10/2009 8/17/2009 8/24/2009 8/31/2009 9/7/2009 9/14/2009 9/21/2009 Quantit 284.4 285.5 288.3 286.2 291.5 285.0 289.4 284.1 292.0 281.0 285.6 284.5 284.4 281.4 284.4 282.2 286.0 273.6 280.9 273.2 275.1 279.2 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.38E-02 1.75E-02 2.48E-02 1.81E-02 2.25E-02 1.95E-02 1.79E-02 1.96E-02 2.05E-02 1.50E-02 1.94E-02 1.87E-02 2.OOE-02 2.40E-02 2.51 E-02 1.87E-02 2.49E-02 2.37E-02 1,96E-02 2.43E-02 2.42E-02 2.62E-02 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 200 1.0 MI WSW - VISITORS CENTER 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 Page 2 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Tipe: Air Cartridge Quantity: cubic meters Analysis: Iodine Activitv: pCi/cubic meter Sample Point 200 200 200 200 200 200 200 200 201 201 201 201 201 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC Samnple Date 11/9/2009 11/16/2009 11/23/2009 11/30/2009 12/7/2009 12/14/2009 12/21/2009 12/28/2009 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/9/2009 Quantity 273.6 272.1 272.9 271.3 270.8 261.6 270.6 271.4 286.0 282.2 277.5 278.0 282.6 276.4 289.4 269.2 277.8 278.2 278.3 286.0 283.3 285.9 Activit'
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.63E-02 2.31 E-02 1.86E-02 2.38E-02 2.31 E-02 1.93E-02 1.69E-02 2.42E-02 2.63E-02 2.42E-02 2.30E-02 1.94E-02 2.02E-02 1.56E-02 2.08E-02 1.89E-02 2.10E-02 1.94E-02 2.37E-02 2.07E-02 1.87E-02 2.11E-02 201 0.5 MI NE - PMAC 201 201 201 201 201 201 201 201 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 2/16/2009 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 Page 3 of 16
BSEP Radiological Environmental Monitoring Analysis Report Aledia Type." A ir Cartridge Quantify: cubic meters Analysis: Iodine Activi*v: pCi/cubic meter Sample.Point 201 201 201 201 201 201 0.5 MI NE - PMAC 0.5 M1 NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 M1 NE - PMAC 0.5 MI NE - PMAC Sample Date 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 201 0.5 MI NE - PMAC 201 0.5 MI NE - PMAC 201 201 201 201 201 201 201 201 201 201 201 201 201 201 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 7/13/2009 7/20/2009 7/27/2009 8/3/2009 8/10/2009 8/17/2009 8/24/2009 8/31/2009 9/7/2009 Quantity 282.7 283.6 285.4 287.0 287.3 289.0 294.0 281.8 289.4 288.3 290.8 288.5 292.6 286.0 291.2 285.5 291.5 284.2 255.8 284.6 284.4 283.5 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.76E-02 1.49E-02 1.85E-02 1.92E-02 1.88E-02 1.93E-02 2.57E-02 2.34E-02 1.72E-02 2.25E-02 1.90E-02 1.65E-02 1.78E-02 2.16E-02 1.38E-02 1.61 E-02 2.05E-02 2.16E-02 2.15E-02 1.82E-02 1.66E-02 1.99E-02 Page 4 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activitv: pCi/cubic meter Sanple Point 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 201 202 202 202 202 202 202 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD Sample Date 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 11/9/2009 11/16/2009 11/23/2009 11/30/2009 12/7/2009 12/14/2009 12/21/2009 12/28/2009 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/9/2009 Quantit 284.6 282.6 285.9 276.5 274.0 275.9 276.3 280.3 275.6 276.5 277.4 273.0 274.2 272.3 271.4 272.4 274.1 270.8 269.9 268.1 272.1 267.2 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.78E-02 2.24E-02 1.85E-02 2.31 E-02 2.12E-02 1.83E-02 1.87E-02 1.77E-02 1.90E-02 1.85E-02 2.80E-02 1.90E-02 2.02E-02 1.63E-02 2.41 E-02 1.84E-02 3.84E-02 2.29E-02 1.89E-02 2.20E-02 2.14E-02 2.12E-02 Page 5 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantify: cubic meters Analysis: Iodine Activitiy: pCi/cubic meter Sample Point 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 202 Saniple.Date 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 7/13/2009 Quantity 271.7 269.5 271.0 266.2 273.7 271.3 272.6 275.2 269.8 271.4 274.5 277.2 277.4 277.4 282.3 277.3 286.1 284.4 286.2 283.8 287.5 280.7 Sample Date Activio'
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.15E-02 1.72E-02 2.38E-02 1.81E-02 2.45E-02 2.15E-02 1.70E-02 1.62E-02 1.22E-02 2.53E-02 1.54E-02 2.55E-02 2.48E-02 2.11E-02 2.15E-02 1.89E-02 1.99E-02 2.01E-02 2.75E-02 2.27E-02 2.10E-02 2.17E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD Page 6 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type. Air Cartridge Quantity: cubic neters Analysis: Iodine Activity:. pCi/cubic meter Sample Point 202 202 202 202 202 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD Sample Date 712012009 712712009 8/3/2009 8/10/2009 811712009 8/24/2009 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 202 202 202 202 202 202 202 202 202 202 202 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/31/2009 9/7/2009 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 11/9/2009 11/16/2009 11/23/2009 11/30/2009 12/7/2009 12/14/2009 Quantity 284.4 278.1 280.3 271.5 274.9 275.4 275.2 273.5 274.6 273.8 277.3 266.3 267.7 266.7 266.0 270.2 263.9 264.5 261.7 257.3 250.8 247.5 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.66E-02 2.05E-02 1.87E-02 2.11E-02 1.75E-02 2.32E-02 1.54E-02 2.40E-02 1.88E-02 1.31 E-02 1.99E-02 2.59E-02 1.90E-02 1.74E-02 2.07E-02 1.78E-02 1.77E-02 1.69E-02 1.98E-02 1.56E-02 2.13E-02 2.53E-02 Page 7 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Tvpe: A ir Cartridge Quantity: cubic meters Analysis: Iodine Activity: pCi/cubic meter Sain lpe Point Sample.Date 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/21/2009 12/28/2009 1/5/2009 1/12/2009 1/19/2009 1/26/2009 2/2/2009 2/9/2009 2/16/2009 2/23/2009 3/2/2009 3/9/2009 3/16/2009 3/23/2009 3/30/2009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009
- Quantit, 297.0 296.0 285.9 282.1 277.5 277.1 283.5 274.2 283.1 278.5 280.5 275.7 285.9 284.4 283.9 287.9 282.0 284.6 288.3 289.4 288.9 288.3 Sample Date Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.49E-02 1.52E-02 2.57E-02 1.93E-02 2.29E-02 1.74E-02 2.13E-02 2.23E-02 2.24E-02 2.21 E-02 2.03E-02 1.93E-02 1.83E-02 2.31 E-02 2.OOE-02 1.90E-02 1.89E-02 2.35E-02 1.89E-02 1.63E-02 1.88E-02 2.25E-02 Page 8 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activit.y pCi/cubic meter Sample Point 203 203 203 203 203 203 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION Sample Date 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 203 2.0 MI SSW - SOUTHPORT SUBSTATION 203 203 203 203 203 203 203 203 203 203 203 203 203 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 7/13/2009 7/20/2009 7/27/2009 8/3/2009 8/10/2009 8/17/2009 8/24/2009 8/31/2009 9/7/2009 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 Quantit 293.8 281.3 261.8 276.9 282.1 281.6 288.0 283.7 290.2 285.8 293.8 287.5 294.0 295.3 296.1 294.9 297.0 296.3 301.2 287.7 298.3 290.0 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.41E-02 2.94E-02 2.18E-02 2.02E-02 1.34E-02 1.92E-02 1.81 E-02 2.26E-02 2.23E-02 1.82E-02 2.12E-02 1.68E-02 1.89E-02 2.01E-02 2.22E-02 1.83E-02 2.06E-02 1.99E-02 2.34E-02 1.72E-02 2.17E-02 2.08E-02 Page 9 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air CarIridge Quantity: cubic meters Analysis: Iodine Activirv: pCi/cubic meter Sample Point Sample Date Quantitv Activit 291.0 203 2.0 MI SSW - SOUTHPORT SUBSTATION 10/26/2009 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/2/2009 295.8 203 2.0 MI SSW - SOUTHPORT SUBSTATION 11/9/2009 291.2 203 2.0 MI SSW-SOUTHPORT SUBSTATION 11/16/2009 293.0 203 2.0 MI SSW-SOUTHPORT SUBSTATION 11/23/2009 291.3 203 2.0 MI SSW-.SOUTHPORT SUBSTATION 11/30/2009 288.1 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/7/2009 288.5 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/14/2009 286.8 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/21/2009 286.7 203 2.0 MI SSW - SOUTHPORT SUBSTATION 12/28/2009 286.4 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/5/2009 296.7 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/12/2009 296.9 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/19/2009 290.3 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 1/26/2009.
287.0 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/2/2009 288.6 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/9/2009 281.0 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 284.7 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/23/2009 280.3 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/212009 282.2 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/9/2009 279.0 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/16/2009 285.1 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 3/23/2009 283.0
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.59E-02 2.15E-02 1.89E-02 2.OOE-02 2.03E-02 1.93E-02 2.14E-02 1.40E-02 2.18E-02 1.90E-02 2.49E-02 2.06E-02 1.79E-02 2.25E-02 2.38E-02 2.06E-02 1.96E-02 2.20E-02 1.90E-02 2.04E-02 1.42E-02 2.29E-02 Page 10 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Tvpe: Air Cartridge Quantity: cubic meters Analysis: Iodine Activity: pCi/cubic meter San*
San ple Point 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 204 22.4 MI NNE - SUTTON PLANT (CONTROL)
Sample Date 3/3012009 4/6/2009 4/13/2009 4/20/2009 4/27/2009 5/4/2009 5/11/2009 5/18/2009 5/25/2009 6/1/2009 6/8/2009 6/15/2009 6/22/2009 6/29/2009 7/6/2009 7/13/2009 7/20/2009 7/27/2009 8/3/2009 8/10/2009 8/17/2009 8/24/2009 Quantity 283.4 284.6 281.0 280.1 280.9 279.9 281.8 278.7 276.9 287.0 284.6 287.4 287.4 287.5 291.2 283.8 286.7 288.2 286.8 288.0 286.5 287.8 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.32E-02 1.95E-02 1.99E-02 2.16E-02 2.36E-02 1.73E-02 1.80E-02 2.07E-02 1.93E-02 1.95E-02 1.96E-02 2.21E-02 1.93E-02 1.55E-02 1.70E-02 2.11E-02 2.23E-02 2.61 E-02 1.84E-02 2.49E-02 2.53E-02 2.07E-02 Page II of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activity: pCi/cubic meter Sample Point 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 205 205 205 205 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE -.SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND Sample Date 8/31/2009 9/7/2009 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 11/9/2009 11/16/2009 11/23/2009 11/30/2009 12/7/2009 12/14/2009 12/21/2009 12/28/2009 1/5/2009 1/12/2009 1/19/2009 1/26/2009 Quantity 287.8 283.9 283.1 286.1 285.5 284.1 284.0 281.6 278.2 283.9 278.9 279.1 283.1 274.2 276.8 275.9 276.2 275.2 294.0 291.7 283.9 282.0 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.10E-02 1.93E-02 2.28E-02 1.76E-02 2.26E-02 2.18E-02 2.05E-02 2.44E-02 2.40E-02 2.31E-02 2.34E-02 2.52E-02 2.14E-02 2.76E-02 1.94E-02 1.93E-02 1.73E-02 1.99E-02 2.65E-02 1.87E-02 1.72E-02 1.80E-02 Page 12 of 16
BSEP Radiological Environmental Monitoring Analysis Report Aledia Type: Air Cartridge Quantity,: cubic meters Analysis: Iodine Activitv: pCi/cubic meter Sample Point Sample Date Quantit Aetivity LLD 205 0.6 MI SSE - SPOIL POND 2/2/2009 288.0
<LLD 1.96E-02 205 0.6 MI SSE - SPOIL POND 2/9/2009 282.9
<LLD 1.95E-02 205 0.6 MI SSE - SPOIL POND 2/16/2009 290.0
<LLD 2.91E-02 205 0.6 MI SSE - SPOIL POND 2/23/2009 278.4
<LLD 2.35E-02 205 0.6 MI SSE - SPOIL POND 3/2/2009 286.3
<LLD 2.23E-02 205 0.6 MI SSE - SPOIL POND 3/9/2009 276.8
<LLD 1.84E-02 205 0.6 MI SSE - SPOIL POND 3/16/2009 300.6
<LLD 2.02E-02 205 0.6 MI SSE - SPOIL POND 3/23/2009 289.7
<LLD 1.67E-02 205 0.6 MI SSE - SPOIL POND 3/30/2009 293.8
<LLD 1.84E-02 205 0.6 MI SSE - SPOIL POND 4/6/2009 304.2
<LLD 1.99E-02 205 0.6 MI SSE - SPOIL POND 4/13/2009 292.2
<LLD 1.63E-02 205 0.6 MI SSE - SPOIL POND 4/20/2009 293.9
<LLD 1.44E-02 205 0.6 MI SSE - SPOIL POND 4/27/2009 306.3
<LLD 1.89E-02 205 0.6 MI SSE - SPOIL POND 5/4/2009 307.7
<LLD 1.73E-02 205 0.6 MI SSE - SPOIL POND 5/11/2009 308.7
<LLD 1.51E-02 205 0.6 MI SSE - SPOIL POND 5/18/2009 306.0
<LLD 2.49E-02 205 0.6 MI SSE - SPOIL POND 5/25/2009 311.8
<LLD 2.17E-02 205 0.6 MI SSE - SPOIL POND 6/1/2009 278.0
<LLD 1.89E-02 205 0.6 MI SSE - SPOIL POND 6/8/2009 285.4
<LLD 1.91E-02 205 0.6 MI SSE - SPOIL POND 6/15/2009 283.6
<LLD 1.77E-02 205 0.6 MI SSE - SPOIL POND 6/22/2009 282.7
<LLD 2.18E-02 205 0.6 MI SSE - SPOIL POND 6/29/2009 281.1
<LLD 2.45E-02 Page 13 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis.: Iodine Activit: pCilcubic meter Sample Point 205 205 205 205 205 205 205 205 205 205 205 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND Sample Date 7/6/2009 7/13/2009 7/20/2009 7/27/2009 8/3/2009 8/10/2009 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 205 0.6 MI SSE - SPOIL POND 8/17/2009 8/24/2009 8/31/2009 9/7/2009 9/14/2009 9/21/2009 9/28/2009 10/5/2009 10/12/2009 10/19/2009 10/26/2009 11/2/2009 11/9/2009 11/16/2009 11/23/2009 11/30/2009 Quantir 284.8 276.3 283.0 279.7 286.7 278.3 281.6 282.6 282.6 279.0 281.7 281.0 286.5 275.1 282.7 274.6 277.0 283.4 275.4 278.4 275.4 273.5 Activity
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 1.64E-02 2.06E-02 2.10E-02 1.98E-02 1.71E-02 1.83E-02 2.11E-02 1.77E-02 2.14E-02 2.36E-02 1.68E-02 2.22E-02 2.07E-02 1.95E-02 1.90E-02 2.09E-02 2.03E-02 1.87E-02 1.86E-02 2.08E-02 1.95E-02 2.07E-02 Page 14 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Air Cartridge Quantity: cubic meters Analysis: Iodine Activitv: pCi/cubic meter Sample Point Samp~le Date Quantit
<LLD 1.81 E-02 205 0.6 MI SSE - SPOIL POND 12/14/2009 272.8
<LLD 2.34E-02 205 0.6 MI SSE - SPOIL POND 12/21/2009 272.8
<LLD 1.55E-02 205 0.6 MI SSE - SPOIL POND 12/28/2009 273.3
<LLD 1.48E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
4/13/2009 283.7
<LLD 1.84E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
4/20/2009 285.4
<LLD 2.OOE-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
4/27/2009 286.2
<LLD 1.95E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
5/4/2009 285.5
<LLD 2.73E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
5/11/2009 288.1
<LLD 2.14E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
5/18/2009 284.8
<LLD 2.45E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
5/25/2009 284.9
<LLD 1.94E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
6/1/2009 284.8
<LLD 2.37E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
6/8/2009 283.3
<LLD 1.65E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
6/15/2009 285.2
<LLD 1.65E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
6/22/2009 285.1
<LLD 2.01E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
6/29/2009 285.7
<LLD 2.07E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
7/6/2009 288.2
<LLD 2.46E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
7/13/2009 281.4
<LLD 2.15E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
7/20/2009 284.4
<LLD 1.34E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
7/27/2009 285.1
<LLD 1.73E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
8/3/2009 283.8
<LLD 2.08E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
8/10/2009 282.7
<LLD 2.33E-02 Page 15 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Tipe: Air Cartridge Quantity: cubic meters Analysis: Iodine Activity: pCi/cubic meter Sample Point Sample Date Quantity Activity LLD 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
8/17/2009 280.8
<LLD 2.14E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
8/24/2009 281.7
<LLD 2.24E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
8/31/2009 280.8
<LLD 1.66E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
9/7/2009 278.4
<LLD 2.48E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
9/14/2009 279.9
.<LLD 1.86E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
9/21/2009 279.0
<LLD 1.96E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
9/28/2009 279.5
<LLD 1.86E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
10/5/2009 278.7
<LLD 2.42E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
10/12/2009 278.6
<LLD 2.01E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
10/19/2009 277.3
<LLD 1.61E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
10/26/2009 271.6
<LLD 1,56E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
11/2/2009 278.3
<LLD 1.93E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
11/9/2009 272.6
<LLD 2.11 E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
11/16/2009 273.7
<LLD 1.21 E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
11/23/2009 277.4
<LLD 2.55E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
11/30/2009 269.2
<LLD 2.35E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
12/7/2009 272.2
<LLD 1.92E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
12/14/2009 271.9
<LLD 1.86E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
12/21/2009 272.9
<LLD 2.13E-02 206 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOVERN.
12/28/2009 270.8
<LLD 2.11E-02 Page 16 of 16
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Fish and Invertebrate Quanmio;v: Grams Analysis: Tritium Concentration (Activitv): pCi/Gram Sample Point Sample Date Quantity Efficiency Activity LLD 706 NANCY'S CREEK - FREE SWIMMERS 9/30/2009 1455
<LLD 8.72E+00 707 NANCY'S CREEK - BOTTOM FEEDERS 9/30/2009 1699
<LLD 8.14E+00 708 NANCY'S CREEK - SH/BO*
9/30/2009 2150
<LLD 8.37E+00
- Shelijisli/Benthic Organisms Page 1 of 1
- ShelqishlBenthie Organisms Page I of I
BSEP Radiological Environmental Monitoring Analysis Report Media Type": Ground Water Quanti*y: Liters Analysis. Tritium Concentiration (Activinj)." pCi/Lier Sample Point Sample Date Quantity Efficiency Activity LLD 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 402 WELL ESS-2C, 0.17 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 403 WELL ESS-16, 0.16 MILES W 1/16/2009 2/20/2009 3/19/2009 4/17/2009 5/15/2009 6/18/2009 7/6/2009 8/10/2009 9/7/2009 10/13/2009 11/9/2009 12/8/2009 1/16/2009 2/20/2009 3/19/2009 4/17/2009 5/15/2009 6/18/2009 7/6/2009 8/10/2009 9/7/2009 10/13/2009 11/8/2009 11/9/2009 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1.04E+06 6.75E+05 6.76E+05 6.22E+05 5.23E+05 5.64E+05 6.37E+05 4.79E+05 4.34E+05 3.26E+05 2.42E+05 2.58E+05 5.28E+03 5.94E+03 5.76E+03 1.21E+04 8.24E+03 8.56E+03 6.08E+03 2.53E+03 3.20E+03 4.21E+03 2.92E+03 3.05E+03 Page 1 of 17
BSEP Radiological Environmental Monitoring Analysis Mlfedia Type: Ground Water Quantity: Liters Analysis: Tritium Concentration (Activiav): pCi/Liter Report Samvle Point Sample Date Ouantitv Efficiency Activity LLD 403 404 404 404 404 404 404 404 404 404 405 405 405 405 405 405 405 405 405 406 406 406 406 406 WELL ESS-16, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-1 B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-2B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, 0.16 MILES W 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.16 MILES SW 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.17 MILES W 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 12/8/2009 1/22/2009 2/19/2009 3/17/2009 4/20/2009 5/18/2009 6/16/2009 7/8/2009 8/4/2009 11/2/2009 1/22/2009 2/23/2009 3/19/2009 4/27/2009 5/15/2009 6/24/2009 7/6/2009 8/10/2009 11/4/2009 1/20/2009 2/18/2009 3/13/2009 4/16/2009 5/6/2009 2.92E+03
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.42E+02 2.34E+02 2.40E+02 2.36E+02 2.41 E+02 2.37E+02 2.40E+02 2.39E+02 2.30E+02 2.44E+02 2.36E+02 2.40E+02 2.36E+02 2.40E+02 2.38E+02 2.35E+02 2.36E+02 2.42E+02 2.38E+02 2.4 1E+02 2.34E'-02 2.39E4-02 2.49E+02 1
1 1
1 Page 2 of 17
BSEP Radiological Environmental Monitoring Analysis Report Media T.ype: Ground Water Quantity. Liters Analysis: Tritium Concentration (Activia.") pCi/Liter Sample Point Sample Date Ouantitv Efficiency Activitv LLD 406 406 406 406 406 406 406 407 407 407 407 407 407 407 407 407 408 408 408 408 408 408 408 408 WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-3B, WELL ESS-13B, WELL ESS-13B, WELL ESS-13B, WELL ESS-13B, WELL ESS-13B, WELL ESS-13B, WELL ESS-1 3, WELL ESS-13B, WELL ESS-13B, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.08 MILES N 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 6/16/2009 7/8/2009 8/5/2009 9/29/2009 10/8/2009 11/2/2009 12/2/2009 1/23/2009 2/19/2009 3/16/2009 4/16/2009 5/15/2009 6/16/2009 7/8/2009 8/11/2009 11/4/2009 1/23/2009 2/19/2009 3/16/2009 4/16/2009 5/15/2009 6/16/2009 7/8/2009 8/11/2009
<LLD
<LLD
<LLD
<LLD 2.84E+02 3.14E+02 2.83E+02
<LLD 2.99E+02
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.39E+02
<LLD 2.36E+02 2.40E+02 2.39E+02 2.40E+02 2.43E+02 2.47E+02 2.39E+02 2.42E+02 2.35E+02 2.39E+02 2.40E+02 2.45E+02 2.47E+02 2.35E+02 2.44E+02 2.36E+02 2.39E+02 2.34E+02 2.40E+02 Page 3 of 17
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Ground Water Quantify: Liters Analysis: Tritium Concentration (Activify): pCi/Liter Sample Point Sample Date Ouantitv Efficiencv Activity LLD 408 408 408 408 409 409 409 409 409 409 409 409 409 409 410 410 410 410 410 410 410 410 410 410 WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-13C, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A, WELL ESS-17A,,
WELL ESS-17A, WELL ESS-17A, WELL ESS-178, WELL ESS-17B, WELL ESS-178, WELL ESS-17B, WELL ESS-17B, WELL ESS-178, WELL ESS-17B, WELL ESS-17B, WELL ESS-17B, WELL ESS-17B, 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.06 MILES ENE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 9/3/2009 10/8/2009 11/4/2009 12/2/2009 1/15/2009 2/10/2009 3/11/2009 4/14/2009 5/11/2009 6/9/2009 7/15/2009 8/5/2009 9/1/2009 12/1/2009 1/15/2009 2/10/2009 3/11/2009 4/14/2009 5/11/2009 6/9/2009 7/15/2009 8/5/2009 9/1/2009 12/1/2009
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.39E+02 2.43E+02 2.54E+02 2.46E+02 2.46E+02 2.41 E+02 2.37E+02 2.37E+02 2.42E+02 2.41 E+02 2.37E+02 2.39E+02 2.33E+02 2.36E+02 2.48E+02 2.41 E+02 2.37E+02 2.38E+02 2.42E+02 2.38E+02 2.34E+02 2.39E+02 2.30E+02 2.32E+02 Page 4 of17 1
1
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Ground Water Quantity: Liters Concentration (Activit).: pCi/Liler Sample Point Analysis: Tritium Sample Date Quantity Efficiency Activity LLD 411 411 411 411 411 411 411 411 411 411 412 412 412 412 412 412 412 412 412 412 413 413 413 413 WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-17C, WELL ESS-188, WELL ESS-18B, WELL ESS-188, WELL ESS-18B, WELL ESS-18B, WELL ESS-18B, WELL ESS-18B, WELL ESS-18B, WELL ESS-18B, WELL ESS-18B, WELL ESS-18C, WELL ESS-18C, WELL ESS-18C, WELL ESS-18C, 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE 0.65 MILES NE NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR (SDSP) STORM DRAIN STABILIZAT NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP 1/15/2009 2/10/2009 3/11/2009 4/14/2009 5/11/2009 6/9/2009 7/15/2009 8/5/2009 9/1/2009 12/1/2009 1/19/2009 2/13/2009 3/11/2009 4/15/2009 5/18/2009 6/11/2009 7/13/2009 8/11/2009 9/15/2009 12/16/2009 1/19/2009 2/12/2009 3/11/2009 4/15/2009 4.24E+03 4.08E+03 4.01 E+03 3.82E+03 4.23E+03 4.27E+03 4.11E+03 4.16E+03 3.73E+03 5.49E+03
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 5.46E+05 5.36E+05 5.38E+05 5.18E+05 2.46E+02 2.35E+02 2.37E+02 2.50E+02 2.39E+02 2.35E+02 2.43E+02 2.36E+02 2.36E+02 2.57E+02 1
1 1
1 PageS5 of] 7
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Ground Water Quantity: Liters Analysis: Tritium Concentration (Activiti): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 413 WELL ESS-18C, NEAR SDSP 5/18/2009 1
2.83E+05 413 WELL ESS-18C, NEAR SDSP 6/11/2009 1
4.90E+05 413 WELL ESS-18C, NEAR SDSP 7/13/2009 1
4.72E+05 413 WELL ESS-18C, NEAR SDSP 8/11/2009 1
4.60E+05 413 WELL ESS-18C, NEAR SDSP 9/15/2009 1
4.51E+05 413 WELL ESS-18C, NEAR SDSP 12/16/2009 1
3.69E+05 414 WELL ESS-19B, NEAR SDSP 1/19/2009 1
4.42E+04 414 WELL ESS-19B, NEAR SDSP 2/13/2009 1
7.12E+04 414 WELL ESS-19B, NEAR SDSP 2/19/2009 1
3.78E+04 414 WELL ESS-19B, NEAR SDSP 3/10/2009 1
5.82E+04 414 WELL ESS-19B, NEAR SDSP 4/21/2009 1
5.13E+04 414 WELL ESS-198, NEAR SDSP 5/19/2009 1
6.85E+04 414 WELL ESS-19B, NEAR SDSP 6/17/2009 1
4.97E+04 414 WELL ESS-19B, NEAR SDSP 7/7/2009 1
5.23E+04 414 WELL ESS-19B, NEAR SDSP 8/10/2009 1
7.53E+04 414 WELL ESS-19B, NEAR SDSP 9/3/2009 1
7.40E+04 414 WELL ESS-19B, NEAR SDSP 10/12/2009 1
4.31E+04 414 WELL ESS-19B, NEAR SDSP 11/3/2009 1
7.65E+04 414 WELL ESS-19B, NEAR SDSP 12/2/2009 1
3.68E+04 414 WELL ESS-19B, NEAR SDSP 12/16/2009 1
2.72E+04 415 WELL ESS-19C, NEAR SDSP 1/19/2009 1
5.26E+05 415 WELL ESS-19C, NEAR SDSP 2/13/2009 1
5.32E+05 415 WELL ESS-19C, NEAR SDSP 2/19/2009 1
5.36E+05 415 WELL ESS-19C, NEAR SDSP 3/10/2009 1
5.52E+05 Page 6 of]17
BSEP Radiological Environmental Monitoring Analysis Mfedia T*pe: Ground Water Quanily: Liters Analysis: Tritium Concetrwation (Activii.'): pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 415 415 415 415 415 415 415 415 415 416 416 416 416 416 416 416 416 416 416 417 417 417 417 417 WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-19C, WELL ESS-20B, WELL ESS-20B, WELL ESS-20B, WELL ESS-20B, WELL ESS-20B, WELL ESS-20B, WELL ESS-20B; WELL ESS-20B, WELL ESS-20B, WELL ESS-20B, WELL ESS-20C, WELL ESS-20C, WELL ESS-20C, WELL ESS-20C, WELL ESS-20C, NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP NEAR SDSP 4/21/2009 5/19/2009 6/17/2009 7/7/2009 8/10/2009 9/3/2009 10/12/2009 11/3/2009 12/2/2009 1/19/2009 2/13/2009 3/10/2009 4/20/2009 5/19/2009 6/17/2009 7/7/2009 8/10/2009 9/15/2009 12/2/2009 1/19/2009 2/13/2009 3/10/2009 4/20/2009 5/19/2009 4.50E+05 5.36E+05 5.33E+05 6.54E+05 5.61 E+05 5.04E+05 5.73E+05 5.44E+05 4.65E+05
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 1.90E+04 1.78E+04 1.83E+04 1.89E+04 1.97E+04 2.45E+02 2.38E+02 2.37E+02 2.33E+02 2.41 E+02 2.39E+02 2.37E+02 2.35E+02 2.46E+02 2.38E+02 Page 7 of 17
BSEP Radiological Environmental Monitoring Analysis Media Type: Ground Water Quanlily: Liiers Analysis: Tritium Concentration (Activity): pCi/Liler Report Sample Point Sample Date Quantity Efficiency Activity LLD 417 417 417 417 417 418 418 418 418 418 418 418 418 418 419 419 419 419 419 419 419 419 419 419 WELL ESS-20C, NEAR SDSP WELL ESS-20C, NEAR SDSP WELL ESS-20C, NEAR SDSP WELL ESS-20C, NEAR SDSP WELL ESS-20C, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21B, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP WELL ESS-21C, NEAR SDSP 6/17/2009 7/7/2009 8/10/2009 9/15/2009 12/2/2009 1/15/2009 2/18/2009 3/12/2009 4/10/2009 5/12/2009 6/17/2009 7/13/2009 8/6/2009 10/8/2009 1/812009 2/18/2009 3/12/2009 4/10/2009 5/12/2009 6/17/2009 7/13/2009 8/6/2009 10/8/2009 11/23/2009 1.93E+04 1.91 E+04 1.86E+04 1.85E+04 2.12E+04
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 4.74E+02 3.70E+02 3.95E+02 3.35E+02 4.35E+02 3.13E+02 3.85E+02 3.03E+02 5.52E+03 5.36E+02 2.48E+02 2.44E+02 2.36E4-02 2.39E+02 2.35E+02 2.39E+02 2.38E+02 2.39E+02 2,44E+02 1
Page 8 of 17
BSEP Radiological Environmental Monitoring Analysis Report Media Tyvle." Ground Water Quantiiy: Liters Analysis: Tritium Concentration (4ActiviaO9: pCi/Liter Sample Point Sample Date Quantitv Efficiency Activity LLD 420 WELL ESS-22B, NEAR SDSP 1/15/2009 1
<LLD 2.44E+02 420 WELL ESS-22B, NEAR SDSP 2/18/2009 1
<LLD 2.42E+02 420 WELL ESS-22B, NEAR SDSP 3/13/2009 1
<LLD 2.34E+02 420 WELL ESS-22B, NEAR SDSP 4/10/2009 1
<LLD 2.39E+02 420 WELL ESS-22B, NEAR SDSP 5/12/2009 1
<LLD 2.38E+02 420 WELL ESS-22B, NEAR SDSP 6/8/2009 1
<LLD 2.34E+02 420 WELL ESS-22B, NEAR SDSP 7/13/2009 1
<LLD 2.37E+02 420 WELL ESS-22B, NEAR SDSP 8/5/2009 1
<LLD 2.39E+02 420 WELL ESS-22B, NEAR SDSP 10/6/2009 1
<LLD 2.43E+02 421 WELL ESS-22C, NEAR SDSP 1/15/2009 1
4.98E+05 421 WELL ESS-22C, NEAR SDSP 2/18/2009 1
6.71E+05 421 WELL ESS-22C, NEAR SDSP 3/13/2009 1
7.15E+05 421 WELL ESS-22C, NEAR SDSP 4/10/2009 1
6.17E+05 421 WELL ESS-22C, NEAR SDSP 5/12/2009 1
7.61E+05 421 WELL ESS-22C, NEAR SDSP 61812009 1
7.65E+05 421 WELL ESS-22C, NEAR SDSP 7/13/2009 1
8.93E+05 421 WELL ESS-22C, NEAR SDSP 8/5/2009 1
8.53E+05 421 WELL ESS-22C, NEAR SDSP 10/6/2009 1
4.35E+05 421 WELL ESS-22C, NEAR SDSP 11/23/2009 1
2.72E+05 422 WELL ESS-23C, NEAR SDSP 1/20/2009 1
1.90E+05 422 WELL ESS-23C, NEAR SDSP 2/13/2009 1
1.77E+05 422 WELL ESS-23C, NEAR SDSP 3/11/2009 1
1.64E+05 422 WELL ESS-23C, NEAR SDSP 4/15/2009 1
1.46E+05 422 WELL ESS-23C, NEAR SDSP 5/18/2009 1
1.40E+05 Page 9 of 17
BSEP Radiological Environmental Monitoring Analysis Report Mfedia Type: Ground Water Quantity: Liters Analysis: Tritium Concentration (Activir,): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 422 WELL ESS-23C, NEAR SDSP 6/11/2009 1
1.51 E+05 422 WELL ESS-23C, NEAR SDSP 7/13/2009 1
1.47E+05 422 WELL ESS-23C, NEAR SDSP 8/12/2009 1
1.55E+05 422 WELL ESS-23C, NEAR SDSP 9/17/2009 1
1.61E+05 422 WELL ESS-23C, NEAR SDSP 12/1/2009 1
1.82E+05 423 WELL ESS-24A, NEAR SDSP 1/15/2009 1
<LLD 2.52E+02 423 WELL ESS-24A, NEAR SDSP 2/12/2009 1
<LLD 2.44E+02 423 WELL ESS-24A, NEAR SDSP 3/12/2009 1
<LLD 2.41E+02 423 WELL ESS-24A, NEAR SDSP 4/21/2009 1
<LLD 2.26E+02 423 WELL ESS-24A, NEAR SDSP 5/11/2009 1
<LLD 2.45E+02 423 WELL ESS-24A, NEAR SDSP 6/9/2009 1
<LLD 2.40E+02 423 WELL ESS-24A, NEAR SDSP 7/15/2009 1
<LLD 2.37E+02 423 WELL ESS-24A, NEAR SDSP 8/5/2009 1
<LLD 2.39E+02 423 WELL ESS-24A, NEAR SDSP 10/6/2009 1
<LLD 2.32E+02 424 WELL ESS-24B, NEAR SDSP 1/15/2009 1
<LLD 2.47E+02 424 WELL ESS-24B, NEAR SDSP 2/12/2009 1
<LLD 2.38E+02 424 WELL ESS-24B, NEAR SDSP 3/12/2009 1
<LLD 2.35E+02 424 WELL ESS-24B, NEAR SDSP 4/14/2009 1
<LLD 2.40E+02 424 WELL ESS-24B, NEAR SDSP 5/12/2009 1
<LLD 2.36E+02 424 WELL ESS-24B, NEAR SDSP 6/9/2009 1
<LLD 2.38E+02 424 WELL ESS-24B, NEAR SDSP 7/15/2009 1
<LLD 2.36E+02 425 WELL ESS-24C, NEAR SDSP 1/15/2009 1
4.57E+03 425 WELL ESS-24C, NEAR SDSP 2/12/2009 1
4.48E+03 425 WELL ESS-24C, NEAR SDSP 3/12/2009 1
4.33E+03 Page 10 of17
BSEP Radiological Environmental Monitoring Analysis itedia Type: Ground Water Quanlily: Liters Analysis. Tritium Concentration (Activit)O: pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 425 425 425 425 425 425 425 426 426 426 426 426 426 426 426.
426 426 427 427 427 427 427 427 427 WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-24C, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25B, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP 4/14/2009 4/21/2009 5/12/2009 6/9/2009 7/15/2009 8/5/2009 10/6/2009 1/22/2009 2/17/2009 3/18/2009 4/17/2009 5/20/2009 6/8/2009 7/20/2009 8/4/2009 9/16/2009 12/9/2009 1/22/2009 2/17/2009 3/18/2009 4/17/2009 5/20/2009 6/8/2009 7/20/2009 1
4.47E+03 1
4.52E+03 1
4.80E+03 1
4.81 E+03 1
4.06E+03 1
4.67E+03 1
5.55E+03 1
<LLD 2.42E+02 1
<LLD 2.36E+02 1
<LLD 2.40E+02 1
<LLD 2.40E+02 1
<LLD 2.37E+02 1
<LLD 2.35E+02 1
<LLD 2.39E+02 1
<LLD 2.38E+02 1
<LLD 2.38E+02 1
<LLD 2.84E+02 1
<LLD 2.44E+02 1
<LLD 2.37E+02 1
<LLD 2.40E+02 1
<LLD 2.43E+02 1
<LLD 2.40E+02 1
<LLD 2.35E+02 1
2.40E+02 Page 11 of 17
BSEP Radiological Environmental Monitoring Analysis Media Tvpe. Ground Water Quantily: Liters Analysis. Tritium Concentration (Actividv)." pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 427 427 427 428 428 428 428 428 428 428 428 428 428 429 429 429 429 429 429 429 429 429 429 430 WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-25C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-26C, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27A, NEAR SDSP WELL ESS-27C, NEAR SDSP 8/412009 9/16/2009 12/9/2009 1/20/2009 2/12/2009 3/13/2009 4/15/2009 5/12/2009 6/11/2009 7/9/2009 8/12/2009 9/16/2009 12/15/2009 1/19/2009 2/13/2009 3/13/2009 4/15/2009 5/18/2009 6/11/2009 7/13/2009 8/12/2009 9/17/2009 12/31/2009 1/20/2009 2.39E+02 2.66E+02 2.53E+02 2.98E+04 9.13E+04 1.44E+05 2.22E+05 2.79E+05 9.19E+04 4.48E+05 4.13E+05 3.80E+05 4.12E+04
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.69E+05 2.46E+02 2.39E+02 2.44E+02 2.38E+02 2.38E+02 2.40E+02 2.43E+02 2.34E+02 2.33E+02 2.43E+02 1
1 1
Page 12 ofJ17
BSEP Radiological Environmental Monitoring Analysis Media Type. Ground Water Quantil,.: Liter 'Y Analysis: Tritium Concentralion (Activity): pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 430 430 430 430 430 430 430 430 430 431 431 431 431 431 431 431 431 431 432 432 432 432 432 432 WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-27C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-30C, NEAR SDSP WELL ESS-31C, NEAR SDSP WELL ESS-31C, NEAR SDSP WELL ESS-31C, NEAR SDSP WELL ESS-31C, NEAR SDSP WELL ESS-31C, NEAR SDSP WELL ESS-31C, NEAR SDSP 2/13/2009 3/13/2009 4/15/2009 5/18/2009 6/11/2009 7/13/2009 8/13/2009 9/17/2009 12/2/2009 1/15/2009 2/12/2009 3/12/2009 4/15/2009 5/12/2009 6/17/2009 7/14/2009 8/6/2009 10/8/2009 1/15/2009 2/12/2009 3/12/2009 4/10/2009 5/12/2009 6/8/2009 2.88E+05 2.80E+05 2.78E+05 2.81 E+05 2.83E+05 2.84E+05 3.OOE+05 3.OOE+05 2.87E+05 1.47E+03 2.31E+03 2.28E+03 1.81E+03 1.79E+03 1.07E+04 6.02E+04 9.72E+04 1.55E+04
<LLD
<LLD 2.78E+02
<LLD
<LLD 4.14E+02 1
2.43E+02 2.42E+02 2.36E+02 2.37E+02 1
1 Page 13 of 17
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Ground Water Quantiy: Liters Analysis: Tritium Concentration (Activity,): pCi/Liler Sample Point Sample Date Quantity Efficiency Activity LLD 432 WELL ESS-31C, NEAR SDSP 7/14/2009 1
1.22E+03 432 WELL ESS-31C, NEAR SDSP 8/6/2009 1
1.71E+03 432 WELL ESS-31C, NEAR SDSP 10/8/2009 1
2.28E+03 433 WELL MW-2, 0.02 MILES S 1/16/2009 1
<LLD 2.45E+02 433 WELL MW-2, 0.02 MILES S 2/20/2009 1
<LLD 2.34E+02 433 WELL MW-2, 0.02 MILES S 3/19/2009 1
<LLD 2.40E+02 433 WELL MW-2, 0.02 MILES S 4/17/2009 1
<LLD 2.39E+02 433 WELL MW-2, 0.02 MILES S 5/18/2009 1
<LLD 2.40E+02 433 WELL MW-2, 0.02 MILES S 6/18/2009 1
<LLD 2.37E+02 433 WELL MW-2, 0.02 MILES S 7/6/2009 1
<LLD 2.34E+02 433 WELL MW-2, 0.02 MILES S 8/10/2009 1
<LLD 2.37E+02 433 WELL MW-2, 0.02 MILES S 10/13/2009 1
3.OOE+02 434 WELL MW-3, 0.03 MILES S 1/16/2009 1
<LLD 2.46E302 434 WELL MW-3, 0.03 MILES S 2/120/2009 1
<LLD 2.36E+02 434 WELL MW-3, 0.03 MILES S 3/19/2009 1
<LLD 2.40E+02 434 WELL MW-3, 0.03 MILES S 4/17/2009 1
<LLD 2.41E+02 434 WELL MW-3, 0.03 MILES S 5/18/2009 1
<LLD 2.40E+02 434 WELL MW-3, 0.03 MILES S 6/18/2009 1
<LLD 2.37E+02 434 WELL MW-3, 0.03 MILES S 7/6/2009 1
<LLD 2.34E+02 434 WELL MW-3, 0.03 MILES S 8/10/2009 1
<LLD 2.36E+02 434 WELL MW-3, 0.03 MILES S 10/13/2009 1
<LLD 2.52E+02 435 WELL ESS-NANCY GREEK-i, (NC-i) 1/28/2009 1
3.12E+02 435 WELL ESS-NANCY CREEK-i, (NC-1) 2/11/2009 1
2.52E+02 435 WELL ESS-NANCY CREEK-i, (NC-1) 3/26/2009 1
4.20E+02 Page 14 of] 7
BSEP Radiological Environmental Monitoring Analysis Report A'fedia Type: Ground Water Quantity: Liters Analysis: Tritium Concentration (Activit.): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 435 WELL ESS-NANCY CREEK-1, (NC-1) 4/10/2009 1
3.74E+02 435 WELL ESS-NANCY CREEK-1, (NC-1) 5/14/2009 1
2.67E+02 435 WELL ESS-NANCY CREEK-1, (NC-1) 6/10/2009 1
<LLD 2.39E+02 435 WELL ESS-NANCY CREEK-1, (NC-1) 7/14/2009 1
<LLD 2.38E+02 435 WELL ESS-NANCY CREEK-i, (NC-1) 8/18/2009 1
<LLD 2.37E+02 435 WELL ESS-NANCY CREEK-1 (NC-1) 9/18/2009 1
<LLD 2.42E+02 435 WELL ESS-NANCY CREEK-1, (NC-1) 12/4/2009 1
2.94E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 1/28/2009 1
<LLD 2.42E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 2/11/2009 1
<LLD 2.45E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 3/26/2009 1
<LLD 2.41E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 4/10/2009 1
<LLD 2.42E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 5/14/2009 1
<LLD 2.36E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 6/10/2009 1
<LLD 2.37E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 7/14/2009 1
<LLD 2.38E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 8/18/2009 1
<LLD 2.37E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 9/18/2009 1
<LLD 2.44E+02 436 WELL ESS-NANCY CREEK-2, (NC-2) 12/4/2009 1
<LLD 2.37E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 1/28/2009 1
<LLD 2.44E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 2/11/2009 1
<LLD 2.35E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 3/26/2009 1
<LLD 2.41E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 4/10/2009 1
<LLD 2.41E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 5/14/2009 1
<LLD 2.36E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 6/10/2009 1
<LLD 2.40E+02 437 WELL ESS-NANCY CREEK-3, (NC-3) 7/9/2009 1
<LLD 2.40E+02 Page 15 ofl7
BSEP Radiological Environmental Monitoring Analysis Report A'ledia Tipe: Ground WVater Quantity. Liters Analysis. Tritium Concentration (Activifiv): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 437 437 437 438 438 438 438 438 438 438 438 438 438 439 439 439 439 439 439 439 439 439 439 440 WELL ESS-NANCY CREEK-3, (NC-3)
WELL ESS-NANCY CREEK-3, (NC-3)
WELL ESS-NANCY CREEK-3, (NC-3)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-4, (NC-4)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-NANCY CREEK-5, (NC-5)
WELL ESS-GUM LOG BRANCH-I, (GLB-1) 8/18/2009 9/18/2009 12/4/2009 1/29/2009 2/11/2009 3/26/2009 4/10/2009 5/14/2009 6/10/2009 7/9/2009 8/18/2009 9/18/2009 12/4/2009 1/29/2009 2/11/2009 3/26/2009 4/10/2009 5/14/2009 6/10/2009 7/9/2009 8/18/2009 9/18/2009 12/4/2009 1/29/2009
<LLD
<LLD
<LLD 3.28E+02
<LLD 3.21 E+02 2.65E+02
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.40E+02 2.43E4-02 2.29E4-02 2.36E+02 2.38E+02 2.39E+02 2.40E+02 2.38E+02 2.42E+02 2.31 E+02 2.41 E+02 2.37E+02 2.44E+02 2.36E+02 2.35E+02 2.38E+02 2.38E+02 2.37E+02 2.44E+02 2.32E+02 2.43E+02 Page 16 of 17
BSEP Radiological Environmental Monitoring Analysis Report MIledia Type: Ground Water Quonfify: Liiers Analysis: Tritium Concentraion (Activiiv)." pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 2/11/2009 1
<LLD 2.38E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 3/26/2009 1
<LLD 2.39E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 4/10/2009 1
<LLD 2.43E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 5/14/2009 1
<LLD 2.35E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 6/10/2009 1
<LLD 2.38E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 7/9/2009 1
<LLD 2.40E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 8/18/2009 1
<LLD 2.36E+02 440 WELL ESS-GUM LOG BRANCH-i, (GLB-1) 9/18/2009 1
<LLD 2.44E+02 440 WELL ESS-GUM LOG BRANCH-1, (GLB-1) 12/4/2009 1
<LLD 2.27E+02 447 WELL ESS-28C, NEAR SDSP 1/20/2009 1
3.09E+02 447 WELL ESS-28C, NEAR SDSP 2/13/2009 1
2.78E+02 447 WELL ESS-28C, NEAR SDSP 3/13/2009 1
4.27E+02 447 WELL ESS-28C, NEAR SDSP 4/15/2009 1
3.97E+02 447 WELL ESS-28C, NEAR SDSP 5/18/2009 1
4.33E+02 447 WELL ESS-28C, NEAR SDSP 6/11/2009 1
3.81 E+02 447 WELL ESS-28C, NEAR SDSP 7/13/2009 1
3.19E+02 447 WELL ESS-28C, NEAR SDSP 8/12/2009 1
4.11E+02 447 WELL ESS-28C, NEAR SDSP 9/17/2009 1
3.62E+02 447 WELL ESS-28C, NEAR SDSP 12/2/2009 1
3.69E+02 Page 17 of 17
BSEP Radiological Environmental Monitoring Hard-To-Detect Analysis Report Media Type: Shoreline Sediment Quantitfy. GRA MS Concentration (Activityv): pCi/gm Sample Point Sample Date Analvsis Activity 2 Sigma Error LLD 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 FE-55
<LLD 2.00E+01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 SR-90
<LLD 2.00E+00 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 SR-89
<LLD 2.00E+00 Page I of I
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Srftice Water Quantity: Liters Concenlralion (Activity)," pCi!Lier Analysis. Tritium Sample Point Sample Date Quantity Efficiency Activity 400 0.6 MI NE - INTAKE CANAL (CONTROL) 1/17/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 2/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 3/17/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 4/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 5/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 6/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 7/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 8/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 9/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 10/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 11/16/2009 400 0.6 MI NE - INTAKE CANAL (CONTROL) 12/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 1/17/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 2/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 3/17/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 5/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 6/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 7/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 401 4.9 MI SSW.- DISCHARGE CANAL @OD PUMPS 10/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 11/16/2009 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 12/16/2009 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 4.05E-01 4.03E-01 4.06E-01 4.07E-01 4.06E-01 4.05E-01 4.04E-01 4.06E-01 4.05E-01 4.05E-01 4.08E-01 3.93E-01 4.05E-01 4.06E-01 4.06E-01 4.07E-01 4.05E-01 4.06E-01 4.05E-01 4.04E-01 4.03E-01 4.07E-01 4.06E-01 3.95E-01
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 5.75E+02
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD LLD 2.35E+02 2.37E+02 2.36E+02 2.36E+02 2.31 E+02 2.07E+02 2.36E+02 2.31 E+02 2.31 E+02 2.37E+02 2.32E+02 2.39E+02 2.35E+02 2.35E+02 2.36E+02 2.36E+02 2.32E+02 2.06E+02 2.36E+02 2.32E+02 2.32E+02 2.36E+02 2.33E+02 2.38E+02 Page 1 of 14
BSEP Radiological Environmental Monitoring Iedia Type: Suijace Water Quanti*y: Liters Analysis: Tritium Concentration (Activio): pCi/fiter Analysis Report Sample Point Sample Date Quantity Efficiency Activity LLD 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 494 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-1 06 NANCY'S CREEK - WP-1 06 NANCY'S CREEK - WP-1 06 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-1 06 NANCY'S CREEK - WP-1 06 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 1/6/2009 1/14/2009 1/21/2009 1/27/2009 2/2/2009 2/10/2009 2/17/2009 2/24/2009 3/4/2009 3/10/2009 3/17/2009 3/24/2009 3/31/2009 4/7/2009 4/14/2009 4/23/2009 4/28/2009 5/6/2009 5/12/2009 5/21/2009 5/27/2009 6/4/2009 6/8/2009 6/16/2009 1
4.76E+02 1
2.70E+02 1
7.29E+02 1
3.23E+02 1
5.45E+02 1
2.66E+02 1
6.31 E+02 1
<LLD 2.44E+02 1
1.1OE+03 1
<LLD 2.35E+02 1
6.05E+02 1
<LLD 2.43E+02 1
2.69E+02 1
3.73E+02 1
<LLD 2.48E+02 1
3.98E+02 1
<LLD 2.40E+02 1
<LLD 2.36E+02 1
<LLD 2.39E+02 1
3.OOE+02 1
2.65E+02 1
<LLD 2.36E+02 1
<LLD 2.36E+02 1
<LLD 2.39E+02 Page 2 of 14
BSEP Radiological Environmental Monitoring Analysis Report AMedia Type: Suiface Wrater Quantity: Liters Analysis: Tritium Concentration (Activity): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 494 NANCY'S CREEK - WP-106 6/23/2009 1
<LLD 2.39E+02 494 NANCY'S CREEK - WP-106 6/29/2009 1
<LLD 2.39E+02 494 NANCY'S CREEK - WP-106 7/7/2009 1
<LLD 2.38E+02 494 NANCY'S CREEK - WP-106 7/14/2009 1
<LLD 2.40E+02 494 NANCY'S CREEK - WP-106 7/21/2009 1
<LLD 2.39E+02 494 NANCY'S CREEK - WP-106 7/29/2009 1
2.66E+02 494 NANCY'S CREEK - WP-106 8/4/2009 1
<LLD 2.37E+02 494 NANCY'S CREEK - WP-106 8/11/2009 1
<LLD 2.36E+02 494 NANCY'S CREEK - WP-1 06 8/17/2009 1
<LLD 2.35E+02 494 NANCY'S CREEK - WP-106 8/24/2009 1
<LLD 2.41E+02 494 NANCY'S CREEK - WP-106 9/2/2009 1
<LLD 2.39E+02 494 NANCY'S CREEK - WP-106 9/9/2009 1
<LLD 2.45E+02 494 NANCY'S CREEK - WP-106 9/15/2009 1
<LLD 2.41 E+02 494 NANCY'S CREEK - WP-106 9/22/2009 1
<LLD 2.38E+02 494 NANCY'S CREEK - WP-106 9/29/2009 1
<LLD 2.37E+02 494 NANCY'S CREEK - WP-106 10/6/2009 1
<LLD 2.36E+02 494 NANCY'S CREEK - WP-1 06 10/13/2009 1
3.15E+02 494 NANCY'S CREEK - WP-106 10/20/2009 1
<LLD 2.31E+02 494 NANCY'S CREEK - WP-1 06 10/27/2009 1
2.79E+02 494 NANCY'S CREEK - WP-106 11/3/2009 1
<LLD 2.44E+02 494 NANCY'S CREEK - WP-106 11/9/2009 1
<LLD 2.34E+02 494 NANCY'S CREEK - WP-106 11/17/2009 1
<LLD 2.44E+02 494 NANCY'S CREEK - WP-106 11/24/2009 1
<LLD 2.28E+02 494 NANCY'S CREEK - WP-106 11/30/2009 1
<LLD 2.36E+02 Page 3 o] 14
BSEP Radiological Environmental Monitoring Analysis Mecdia Type: Sufiace Water Quantity: Liter:s Analysis: Tritium Concentvratio (Activity): pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 494 494 494 494 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 495 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-106 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 12/7/2009 12/15/2009 12/21/2009 12/29/2009 1/6/2009 1/14/2009 1/21/2009 1/27/2009 2/2/2009 2/10/2009 2/17/2009 2/24/2009 3/5/2009 3/10/2009 3/17/2009 3/24/2009 3/31/2009 4/7/2009 4/14/2009 4/23/2009 4/28/2009 5/6/2009 5/12/2009 5/21/2009
<LLD
<LLD
<LLD 2.49E+02 2.46E+02 2.51 E+02 2.45E+02
<LLD
<LLD
<LLD
<LLD
<LLD 2.64E+02
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.37E+02 2.56E+02 2.18E+02 2.44E+02 2.38E+02 2.33E+02 2.37E+02 2.36E+02 2.36E+02 2.42E+02 2.48E+02 2.45E+02 2.36E'-02 2.43E+02 2.35E+02 2.40E+02 2.36E+02 2.41 E+02 2.38E+02 1
1 1
Page 4 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Swuface Water Quantity: Liteis Analysis. Tritium Concentration (Activity): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 495 NANCY'S CREEK - WP-52 5/27/2009 1
<LLD 2.31 E+02 495 NANCY'S CREEK - WP-52 6/4/2009 1
<LLD 2.37E+02 495 NANCY'S CREEK - WP-52 6/8/2009 1
<LLD 2.38E+02 495 NANCY'S CREEK - WP-52 6/16/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 6/23/2009 1
<LLD 2.39E+02 495 NANCY'S CREEK - WP-52 6/29/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 7/7/2009 1
<LLD 2.38E+02 495 NANCY'S CREEK - WP-52 7/14/2009 1
<LLD 2.38E+02 495 NANCY'S CREEK - WP-52 7/21/2009 1
<LLD 2.37E+02 495 NANCY'S CREEK - WP-52 7/29/2009 1
<LLD 2.35E+02 495 NANCY'S CREEK - WP-52 8/4/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 8/11/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 8/17/2009 1
<LLD 2.33E+02 495 NANCY'S CREEK - WP-52 8/24/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 9/2/2009 1
<LLD 2.33E+02 495 NANCY'S CREEK - WP-52 9/9/2009 1
<LLD 2.40E+02 495 NANCY'S CREEK - WP-52 9/15/2009 1
<LLD 2.31E+02 495 NANCY'S CREEK - WP-52 9/22/2009 1
<LLD 2.36E+02 495 NANCY'S CREEK - WP-52 9/29/2009 1
<LLD 2.36E+02 495 NANCY'S CREEK - WP-52 10/6/2009 1
<LLD 2.32E+02 495 NANCY'S CREEK - WP-52 10/13/2009 1
<LLD 2.38E+02 495 NANCY'S CREEK - WP-52 10/20/2009 1
<LLD 2.33E+02 495 NANCY'S CREEK - WP-52 10/27/2009 1
<LLD 2.34E+02 495 NANCY'S CREEK - WP-52 11/3/2009 1
<LLD 2.35E+02 Page 5 of 14
BSEP Radiological Environmental Monitoring Analysis Report AMedia Type: Surface Water Quantity: Liters Concentration (Activity).: pCi/Liter Sample Point Analysis: Tritium Sample Date Quantity Efficiency Activity LLD 495 495 495 495 495 495 495 495 496 496 496 496 496 496 496 496 496 496 496 496 496 496 496 496 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-52 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 NANCY'S CREEK - WP-53 11/9/2009 11/17/2009 11/24/2009 11/30/2009 12/712009 12/15/2009 12/21/2009 12/29/2009 1/6/2009 1/14/2009 1/21/2009 1/27/2009 2/2/2009 2/10/2009 2/17/2009 2/24/2009 3/5/2009 3/10/2009 3/17/2009 3/24/2009 3131/2009 4/7/2009 4/14/2009 4/23/2009 1
<LLD 2.33E+02 1
<LLD 2.42E+02 1
<LLD 2.25E+02 1
<LLD 2.37E+02 1
<LLD 2.26E+02 1
<LLD 2.28E+02 1
<LLD 2.30E+02 1
<LLD 2.34E+02 1
<LLD 2.41E+02 1
3.51 E+02 1
8.78E+02 1
2.87E+02 1
<LLD 2.40E+02 1
<LLD 2.33E+02 1
<LLD 2.39E+02 1
2.99E+02 1
3.29E+02 1
<LLD 2.36E+02 1
<LLD 2.41E+02 1
<LLD 2.52E+02 1
<LLD 2.43E+02 1
<LLD 2.35E+02 1
<LLD 2.46E+02 1
<LLD 2.37E+02 Page 6 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Strfaice Water Quantity: Liters Analysis: Tritium Concentration (Activitv).: pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 496 NANCY'S CREEK - WP-53 4/28/2009 1
<LLD 2.42E+02 496 NANCY'S CREEK - WP-53 5/6/2009 1
<LLD 2.37E+02 496 NANCY'S CREEK - WP-53 5/12/2009 1
<LLD 2.40E+02 496 NANCY'S CREEK - WP-53 5/21/2009 1
<LLD 2.38E+02 496 NANCY'S CREEK - WP-53 5/27/2009 1
<LLD 2.34E+02 496 NANCY'S CREEK - WP-53 6/4/2009 1
<LLD 2.37E+02 496 NANCY'S CREEK - WP-53 6/8/2009 1
<LLD 2.37E+02 496 NANCY'S CREEK - WP-53 6/16/2009 1
<LLD 2.38E+02 496 NANCY'S CREEK - WP-53 6/23/2009 1
<LLD 2.38E+02 496 NANCY'S CREEK - WP-53 6/29/2009 1
<LLD 2.38E+02 496 NANCY'S CREEK - WP-53 7/7/2009 1
<LLD 2.40E+02 496 NANCY'S CREEK - WP-53 7/17/2009 1
<LLD 2.36E+02 496 NANCY'S CREEK - WP-53 7/21/2009 1
<LLD 2.38E+02 496 NANCY'S CREEK - WP-53 7/29/2009 1
<LLD 2.35E+02 496 NANCY'S CREEK - WP-53 8/4/2009 1
<LLD 2.39E+02 496 NANCY'S CREEK - WP-53 8/11/2009 1
<LLD 2.39E+02 496 NANCY'S CREEK - WP-53 8/17/2009 1
<LLD 2.33E+02 496 NANCY'S CREEK - WP-53 8/24/2009 1
<LLD 2.39E+02 496 NANCY'S CREEK - WP-53 9/2/2009 1
<LLD 2.34E+02 496 NANCY'S CREEK - WP-53 9/9/2009 1
<LLD 2.40E+02 496 NANCY'S CREEK - WP-53 9/15/2009 1
<LLD 2.31E+02 496 NANCY'S CREEK - WP-53 9/22/2009 1
<LLD 2.36E+02 496 NANCY'S CREEK - WP-53 9/29/2009 1
<LLD 2.32E+02 496 NANCY'S CREEK - WP-53 10/6/2009 1
<LLD 2.32E+02 Page 7 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type.: Swface Vater Quantity: Liters Analysis. Tritium Concentration (Activi."): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 496 NANCY'S CREEK - WP-53 10/13/2009 1
<LLD 2.34E+02 496 NANCY'S CREEK - WP-53 10/20/2009 1
<LLD 2.35E+02 496 NANCY'S CREEK - WP-53 10/27/2009 1
<LLD 2.31E+02 496 NANCY'S CREEK - WP-53 11/3/2009 1
<LLD 2.31E+02 496 NANCY'S CREEK - WP-53 11/9/2009 1
<LLD 2.34E+02 496 NANCY'S CREEK - WP-53 11/17/2009 1
<LD 2.42E+02 496 NANCY'S CREEK - WP-53 11/24/2009 1
<LLD 2.28E+02 496 NANCY'S CREEK - WP-53 11/30/2009 1
<LLD 2.35E+02 496 NANCY'S CREEK - WP-53 12/7/2009 1
<LLD 2.29E+02 496 NANCY'S CREEK - WP-53 12/15/2009 1
<LLD 2.30E+02 496 NANCY'S CREEK - WP-53 12/21/2009 1
<LLD 2.27E+02 496 NANCY'S CREEK - WP-53 12/29/2009 1
2.46E+02 497 NANCY'S CREEK - WP-55 1/6/2009 1
2.97E+02 497 NANCY'S CREEK - WP-55 1/14/2009 1
5.04E+02 497 NANCY'S CREEK - WP-55 1/21/2009 1
7.14E+02 497 NANCY'S CREEK - WP-55 1/27/2009 1
4.23E+02 497 NANCY'S CREEK - WP-55 2/2/2009 1
<LLD 2.43E+02 497 NANCY'S CREEK - WP-55 2/10/2009 1
<LLD 2.34E+02 497 NANCY'S CREEK - WP-55 2/17/2009 1
2.78E+02 497 NANCY'S CREEK - WP-55 2/24/2009 1
<LLD 2.41E+02 497 NANCY'S CREEK - WP-55 3/5/2009 1
2.98E+02 497 NANCY'S CREEK - WP-55 3/10/2009 1
<LLD 2.35E+02 497 NANCY'S CREEK - WP-55 3/17/2009 1
<LLD 2.40E+02 497 NANCY'S CREEK - WP-55 3/24/2009 1
<LLD 2.52E+02 Page 8 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Sjiface Waler Quantiiy: Liters Analysis: Tritium Concentration (Aclivi.i") pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 497 NANCY'S CREEK - WP-55 3/31/2009 1
<LLD 2.44E+02 497 NANCY'S CREEK - WP-55 4/7/2009 1
<LLD 2.35E+02 497 NANCY'S CREEK - WP-55 4/14/2009 1
<LLD 2.45E+02 497 NANCY'S CREEK - WP-55 4/23/2009 1
<LLD 2.37E+02 497 NANCY'S CREEK - WP-55 4/28/2009 1
<LLD 2.42E+02 497 NANCY'S CREEK - WP-55 5/6/2009 1
<LLD 2.37E+02 497 NANCY'S CREEK - WP-55 5/12/2009 1
<LLD 2.40E+02 497 NANCY'S CREEK - WP-55 5/21/2009 1
<LLD 2.38E+02 497 NANCY'S CREEK - WP-55 5/27/2009 1
<LLD 2.36E+02 497 NANCY'S CREEK - WP-55 6/4/2009 1
<LLD 2.36E+02 497 NANCY'S CREEK - WP-55 6/8/2009 1
<LLD 2.37E+02 497 NANCY'S CREEK - WP-55 6/16/2009 1
<LLD 2.38E+02 497 NANCY'S CREEK - WP-55 6/23/2009 1
<LLD 2.39E+02 497 NANCY'S CREEK - WP-55 6/29/2009 1
<LLD 2.38E+02 497 NANCY'S CREEK - WP-55 7/7/2009 1
<LLD 2.40E+02 497 NANCY'S CREEK - WP-55 7/14/2009 1
<LLD 2.34E+02 497 NANCY'S CREEK - WP-55 7/21/2009 1
<LLD 2.37E+02 497 NANCY'S CREEK - WP-55 7/29/2009 1
<LLD 2.35E+02 497 NANCY'S CREEK - WP-55 8/4/2009 1
<LLD 2.40E+02 497 NANCY'S CREEK - WP-55 8/11/2009 1
<LLD 2.38E+02 497 NANCY'S CREEK - WP-55 8/17/2009 1
<LLD 2.33E+02 497 NANCY'S CREEK - WP-55 8/24/2009 1
<LLD 2.40E+02 497 NANCY'S CREEK - WP-55 9/2/2009 1
<LLD 2.36E+02 497 NANCY'S CREEK - WP-55 9/9/2009 1
<LLD 2.40E+02 Page 9 of 14
BSEP Radiological Environmental Monitoring Analysis Media Type: Swfiace Water Quantity: Liters Analysis: Tritium Concentration (ActiviyO): pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activity LLD 497 497 497 497 497 497 497 497 497 497 497 497 497 497 497 497 498 498 498 498 498 498 498 498 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-55 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 NANCY'S CREEK - WP-57 9/15/2009 9/22/2009 9/29/2009 10/6/2009 10/13/2009 10/20/2009 10/27/2009 11/3/2009 11/9/2009 11/17/2009 11/24/2009 11/30/2009 12/7/2009 12/15/2009 12/21/2009 12/29/2009 1/6/2009 1/14/2009 1/21/2009 1/27/2009 2/2/2009 2/10/2009 2/17/2009 2/24/2009
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 3.99E+02 3.56E+02 7.65E+02 3.39E+02 3.02E+02
<LLD
<LLD 2.86E+02 2.31 E+02 2.37E+02 2.32E+02 2.31 E+02 2.30E+02 2.37E+02 2.34E+02 2.29E+02 2.34E+02 2.43E+02 2.23E+02 2.35E+02 2.33E+02 2.34E+02 2.24E+02 2.41 E+02 2.36E+02 2.39E+02 1
1 1
1 1
1 Page 10 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Sujfce Water Quantity Liters Analysis: Tritium Concentration (,4ctiviOv): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 498 NANCY'S CREEK - WP-57 3/5/2009 1
4.94E+02 498 NANCY'S CREEK - WP-57 3/10/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57
.3/17/2009 1
4.55E+02 498 NANCY'S CREEK - WP-57 3/24/2009 1
<LLD 2.50E+02 498 NANCY'S CREEK - WP-57 3/31/2009 1
<LLD
- 2.44E+02 498 NANCY'S CREEK - WP-57 4/7/2009 1
<LLD 2.34E+02 498 NANCY'S CREEK - WP-57 4/14/2009 1
<LLD 2.46E+02 498 NANCY'S CREEK - WP-57 4/23/2009 1
<LLD 2.36E+02 498 NANCY'S CREEK - WP-57 4/28/2009 1
2.51 E+02 498 NANCY'S CREEK - WP-57 5/6/2009 1
3.02E+02 498 NANCY'S CREEK - WP-57 5/12/2009 1
<LLD 2.40E+02 498 NANCY'S CREEK - WP-57 5/21/2009 1
<LLD 2.39E+02 498 NANCY'S CREEK - WP-57 5/27/2009 1
<LLD 2.36E+02 498 NANCY'S CREEK - WP-57 6/4/2009 1
<LLD 2.38E+02 498 NANCY'S CREEK - WP-57 6/8/2009 1
<LLD 2.37E+02 498 NANCY'S CREEK - WP-57 6/16/2009 1
<LLD 2.37E+02 498 NANCY'S CREEK - WP-57 6/23/2009 1
<LLD 2.39E+02 498 NANCY'S CREEK - WP-57 6/29/2009 1
<LLD 2.36E+02 498 NANCY'S CREEK - WP-57 7/7/2009 1
<LLD 2.39E+02 498 NANCY'S CREEK - WP-57 7/14/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 7/21/2009 1
<LLD 2.38E+02 498 NANCY'S CREEK - WP-57 7/29/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 8/4/2009 1
<LLD 2.38E+02 498 NANCY'S CREEK - WP-57 8/11/2009 1
<LLD 2.39E+02 Page 11 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Suiface Walter Quantify: Liters Analysis: Tritium Concentration (ActivivO.) pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 498 NANCY'S CREEK - WP-57 8/17/2009 1
<LLD 2.34E+02 498 NANCY'S CREEK - WP-57 8/24/2009 1
<LLD 2.42E+02 498 NANCY'S CREEK - WP-57 9/2/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 9/9/2009 1
<LLD 2.34E+02 498 NANCY'S CREEK - WP-57 9/15/2009 1
<LLD 2.33E+02 498 NANCY'S CREEK - WP-57 9/22/2009 1
<LLD 2.39E+02 498 NANCY'S CREEK - WP-57 9/29/2009 1
<LLD 2.36E+02 498 NANCY'S CREEK - WP-57 10/6/2009 1
<LLD 2.33E+02 498 NANCY'S CREEK - WP-57 10/13/2009 1
<LLD 2.33E+02 498 NANCY'S CREEK - WP-57 10/20/2009 1
<LLD 2.34E+02 498 NANCY'S CREEK - WP-57 10/27/2009 1
2.83E+02 498 NANCY'S CREEK - WP-57 11/3/2009 1
<LLD 2.33E+02 498 NANCY'S CREEK - WP-57 11/9/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 11/17/2009 1
<LLD 2.44E+02 498 NANCY'S CREEK - WP-57 11/24/2009 1
<LLD 2.25E+02 498 NANCY'S CREEK - WP-57 11/30/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 12/7/2009 1
<LLD 2.35E+02 498 NANCY'S CREEK - WP-57 12/15/2009 1
<LLD 2.33E+02 498 NANCY'S CREEK - WP-57 12/21/2009 1
2.83E+02 498 NANCY'S CREEK - WP-57 12/29/2009 1
2.83E+02 499 CAPE FEAR RIVER - WP CONTROL 1/6/2009 1
<LLD 2.40E+02 499 CAPE FEAR RIVER - WP CONTROL 1/14/2009 1
<LLD 2.40E+02 499 CAPE FEAR RIVER - WP CONTROL 1/21/2009 1
<LLD 2.51E+02 499 CAPE FEAR RIVER - WP CONTROL 1/27/2009 1
<LLD 2.39E+02 Page 12 of 14
BSEP Radiological Environmental Monitoring Analysis Media Tvpe: Suiac e Waler Quanti'y: Liters Analysis: Tritium Concentration (Activit.): pCi/Liter Report Sample Point Sample Date Quantity Efficiency Activitv LLD 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 499 CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL CAPE FEAR RIVER - WP CONTROL 2/2/2009 2/10/2009 2/17/2009 2/24/2009 3/5/2009 3/10/2009 3/17/2009 3/24/2009 3/31/2009 4/7/2009 4/14/2009 4/23/2009 4/28/2009 5/6/2009 5/12/2009 5/21/2009 5/27/2009 6/4/2009 6/8/2009 6/16/2009 6/23/2009 6/29/2009 7/7/2009 7/14/2009
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD
<LLD 2.49E+02 2.38E+02 2.37E+02 2.35E+02 2.34E+02 2.36E+02 2.39E+02 2.47E+02 2.43E+02 2.36E+02 2.47E+02 2.38E+02 2.33E+02 2.36E+02 2.40E+02 2.39E+02 2.36E+02 2.38E+02 2.39E+02 2.38E+02 2.40E+02 2.31E+02 2.35E+02 2.38E+02 Page 13 of 14
BSEP Radiological Environmental Monitoring Analysis Report Media Type: Suiface Waler Quantiy." Liters Analysis: Tritium Concentration (Activiy.): pCi/Liter Sample Point Sample Date Quantity Efficiency Activity LLD 499 CAPE FEAR RIVER - WP CONTROL 7/21/2009 1
<LLD 2.38E+02 499 CAPE FEAR RIVER - WP CONTROL 7/29/2009 1
<LLD 2.37E+02 499 CAPE FEAR RIVER - WP CONTROL 8/4/2009 1
<LLD 2.39E+02 499 CAPE FEAR RIVER - WP CONTROL 8/11/2009 1
<LLD 2.40E+02 499 CAPE FEAR RIVER - WP CONTROL 8/17/2009 1
<LLD 2.33E+02 499 CAPE FEAR RIVER - WP CONTROL 8/24/2009 1
<LLD 2.39E+02 499 CAPE FEAR RIVER - WP CONTROL 9/2/2009 1
<LLD 2.40E+02 499 CAPE FEAR RIVER - WP CONTROL 9/9/2009 1
<LLD 2.39E+02 499 CAPE FEAR RIVER - WP CONTROL 9/15/2009 1
<LLD 2.33E+02 499 CAPE FEAR RIVER - WP CONTROL 9/22/2009 1
<LLD 2.39E+02 499 CAPE FEAR RIVER - WP CONTROL 9/29/2009 1
<LLD 2.38E+02 499 CAPE FEAR RIVER - WP CONTROL 10/6/2009 1
<LLD 2.34E+02 499 CAPE FEAR RIVER - WP CONTROL 10/13/2009 1
<LLD 2.35E+02 499 CAPE FEAR RIVER - WP CONTROL 10/20/2009 1
<LLD 2.32E+02 499 CAPE FEAR RIVER - WP CONTROL 10/27/2009 1
<LLD 2.36E+02 499 CAPE FEAR RIVER - WP CONTROL 11/3/2009 1
<LLD 2.36E+02 499 CAPE FEAR RIVER - WP CONTROL 11/9/2009 1
<LLD 2.33E+02 499 CAPE FEAR RIVER - WP CONTROL 11/17/2009 1
<LLD 2.44E+02 499 CAPE FEAR RIVER - WP CONTROL 11/24/2009 1
<LLD 2.32E+02 499 CAPE FEAR RIVER - WP CONTROL 11/30/2009 1
<LLD 2.34E+02 499 CAPE FEAR RIVER - WP CONTROL 12/7/2009 1
<LLD 2.36E+02 499 CAPE FEAR RIVER-WP CONTROL 12/15/2009 1
<LLD 2.34E+02 499 CAPE FEAR RIVER - WP CONTROL 12/21/2009 1
<LLD 2.28E+02 499 CAPE FEAR RIVER - WP CONTROL 12/29/2009 1
<LLD 2.45E+02 Page 14 of 14
2009 BSEP Radiological Environmental Monitoring Gamma Isotopic Report Comments All AC and AP samples were available during 2009.
Aquatic organism monitoring includes fish (free swimmers and bottom feeders), invertebrates (shellfish - (SH)), and Benthic organisms (BO). Invertebrates in the Gamma Isotopic data are represented by SHIBO*.
Gamma results are Less than LLD (< LLD) and do not appear in the Gamma Isotopic Report for the following samples:
Fish and Invertebrate samples (706 - 708)
Ground Water samples (402 - 440 and 447)
Surface Water samples (494 - 499)
BSEP Radiological Environmental Monitoring Gamma Isotopic M'fedia T.pe: Air Particulate Quantii'v: CUBIC METERS Concentration (Activity): pCi/cubic meter Sample Point Sample Date Quantity Isotope Activity Report 2 Sigma Error 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 201 201 201 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW-VISITORS CENTER 1.0 MI WSW -VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 1.0 MI WSW - VISITORS CENTER 0.5 MI NE - PMAC 0.5 MI NE - PMAC 0.5 MI NE - PMAC 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 2/16/2009 2/16/2009 2/16/2009 3617.9 3617.9 3617.9 3617.9 3617.9 3843.7 3843.7 3843.7 3843.7 3711.5 3711.5 3711.5 3711.5 3711.5 3711.5 3711.5 3546.3 3546.3 3546.3 3546.3 3546.3 3644.9 3644.9 3644.9 BE-7 K-40 PB-212 BI-214 PB-214 K-40 BI-214 PB-214 BE-7 TL-208 K-40 BI-214 PB-214 RA-226 TH-234 BE-7 K-40 PB-212 TH-234 BE-7 RA-226 K-40 PB-214 BE-7 1.46E-01 2.03E-02 1.02E-03 3.20E-03 4.76E-03 4.93E-02 1.55E-03 2.71 E-03 1.33E-01 6.02E-04 2.85E-02 3.73E-03 4.97E-03 1.42E-02 1.56E-02 1.15E-01 5.91 E-02 1.04E-03 1.57E-02 1.01E-01 1.63E-02 3.90E-02 6.45E-03 1.49E-01 1.80E-02 7.48E-03 7.23E-04 1.49E-03 1.19E-03 9.89E-03 1.27E-03 1.36E-03 1.75E-02 5.12E-04 8.78E-03 1.16E-03 1.25E-03 7.31 E-03 1.07E-02 1.64E-02 1.11E-02 6.58E-04 1.37E-02 1.63E-02 9.18E-03 9.55E-03 1.34E-03 1.93E-02 Page I of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Air Particulate Quantiot: CUBIC METERS Concentration (Activit.): pCi/cubic me/er Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 201 0.5 MI NE - PMAC 2/16/2009 3644.9 TL-208 9.80E-04 6.11E-04 201 0.5 MI NE - PMAC 2/16/2009 3644.9 RA-226 1.71 E-02 7.63E-03 201 0.5 MI NE - PMAC 2/16/2009 3644.9 BI-214 6.40E-03 1.60E-03 201 0.5 MI NE-PMAC 2/16/2009 3644.9 PB-212 2.82E-03 7.25E-04 201 0.5 MI NE - PMAC 5/18/2009 3733.7 PB-214 5.40E-03 1.38E-03 201 0.5 MI NE-PMAC 5/18/2009 3733.7 K-40 2.54E-02 1.09E-02 201 0.5 MI NE - PMAC 5/18/2009 3733.7 TH-234 1.69E-02 1.03E-02 201 0.5 MI NE - PMAC 5/18/2009 3733.7 BI-214 4.34E-03 1.34E-03 201 0.5 MI NE - PMAC 5/18/2009 3733.7 BE-7 1.22E-01 1.64E-02 201 0.5 MI NE - PMAC 5/18/2009 3733.7 RA-226 1.43E-02 1.23E-02 201 0.5 MI NE - PMAC 8/17/2009 3692.4 RA-226 1.57E-02 8.OOE-03 201 0.5 MI NE - PMAC 8/17/2009 3692.4 PB-214 6.28E-03 1.24E-03 201 0.5 MI NE - PMAC 8/17/2009 3692.4 BI-214 5.22E-03 1.32E-03 201 0.5 MI NE - PMAC 8/17/2009 3692.4 PB-212 1.49E-03 5.89E-04 201 0.5 MI NE - PMAC 8/17/2009 3692.4 K-40 2.09E-02 8.84E-03 201 0.5 MI NE - PMAC 8/17/2009 3692.4 BE-7 1.19E-01 1.60E-02 201 0.5 MI NE - PMAC 11/16/2009 3575.8 BE-7 1.02E-01 1.56E-02 201 0.5 MI NE - PMAC 11/16/2009 3575.8 BI-214 4.32E-03 1.94E-03 201 0.5 MI NE - PMAC 11/16/2009 3575.8 K-40 6.81E-02 1.45E-02 201 0.5 MI NE - PMAC 11/16/2009 3575.8 PB-214 3.82E-03 1.79E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 K-40 2.32E-02 8.29E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 TL-208 4.81E-04 3.98E-04 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 TH-234 1.27E-02 1.07E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 PB-212 1.45E-03 7.79E-04 Page 2 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Mkedia Type: Air Particulate Quantiov: CUBIC METERS Concentration Llctivitri: pCi/cubic meter Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 BI-214 7.64E-03 1.49E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 PB-214 6.27E-03 1.27E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 RA-226 1.88E-02 9.82E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 2/16/2009 3518.2 BE-7 1.61E-01 1.90E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 PB-214 4.34E-03 1.43E-03 202 1.0 MI S-SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 BE-7 1.32E-01 1.91E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 RA-226 1.42E-02 8.88E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 K-40 2.74E-02 7.66E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 PB-212 1.76E-03 1.16E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 5/18/2009 3623 BI-214 3.78E-03 1.30E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 PB-214 1.61 E-03 1.05E-03 202 1.0 MI S-SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 BE-7 1.18E-01 1.80E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 TL-208 1.14E-03 6.04E-04 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 BI-214 1.84E-03 1.09E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 PB-212 1.43E-03 7.77E-04 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 K-40 5.88E-02 1.16E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 8/17/2009 3607.2 RA-226 2.99E-02 1.17E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 BI-214 7.77E-03 1.46E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 PB-214 7.85E-03 1.61E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 PB-212 1.59E-03 7.OOE-04 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 K-40 3.60E-02 9.08E-03 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 BE-7 1.07E-01 1.69E-02 202 1.0 MI S - SUBSTATION ON CONSTRUCTION RD 11/16/2009 3475.6 RA-226 2.45E-03 1.27E-03 203 2.0 MI SSW - SOUTHPORT SUBSTATION 2/16/2009 3652.1 BI-214 3.46E-03 1.50E-03 Page 3 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report AMedia Type: Air Particulate Quantitv: CUBIC METERS Concentration (Activity): pCi/cubic meter Sample Point Sample Date Ouantitv Isotope Activity 2 Siama Error Sam pie Point Sample Date 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 204 204 204 204 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 2.0 MI SSW - SOUTHPORT SUBSTATION 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 2/16/2009 2/16/2009 2/16/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009
.11/16/2009 11/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 3652.1 3652.1 3652.1 3652.1 3686.9 3686.9 3686.9 3686.9 3686.9 3803.8 3803.8 3803.8 3803.8 3774.8 3774.8 3774.8 3774.8 3774.8 3774.8 3774.8 3718.2 3718.2 3718.2 3718.2 PB-214 BE-7 K-40 RA-226 RA-226 PB-212 TH-234 BE-7 K-40 PB-214 BI-214 K-40 BE-7 RA-226 PB-214 BI-214 PB-212 K-40 BE-7 TL-208 PB-212 TH-234 K-40 BI-214 4.40E-03 1.51 E-01 2.24E-02 1.83E-02 1.76E-02 1.41 E-03 2.03E-02 1.22E-01 4.85E-02 3.91 E-03 1.91E-03 5.86E-02 1.32E-01 1.34E-02 6.06E-03 4.OOE-03 1.14E-03 2.50E-02 1.04E-01 6.34E-04 1.71 E-03 1.47E-02 3.57E-02 4.29E-03 1.23E-03 1.82E-02 7.41 E-03 1.05E-02 1.08E-02 8.02E-04 1.14E-02 1.74E-02 1.0 1E-02 1.38E-03 1.14E-03 1.10 E-02 1.76E-02 8.13E-03 1.34E-03 1.56E-03 5.74E-04 8.7KE-03 1.66E-02 5.70E-04 7.23E-04 1.02E-02 8.24E-03 1.12E-03 Page 4 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Air Particulate Quantity: CUBIC METERS Concentration (Aclivitv,): pCi/cubic meter Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 3718.2 PB-214 4.12E-03 1.28E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 3718.2 RA-226 1.68E-02 9.03E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 3718.2 BE-7 1.47E-01 1.87E-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 2/16/2009 3718.2 TL-208 9.42E-04 4.86E-04 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/18/2009 3677.8 K-40 7.07E-02 1.30E-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/18/2009 3677.8 PB-212 1.07E-03 8.59E-04 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/18/2009 3677.8 BI-214 2.02E-03 1.22E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 5/18/2009 3677.8 BE-7 1.46E-01 2.02E-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 TH-234 1.13E-02 9.94E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 BE-7 1.14E-01 1.68E-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 K-40 2.20E-02 8.09E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 TL-208 6.49E-04 4.48E-04 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 PB-212 9.74E-04 5.69E-04 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 BI-214 5.17E-03 1.23E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 RA-226 1.40E-02 8.43E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 8/17/2009 3725.4 PB-214 6.52E-03 1.17E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 BE-7 1.12E-01 1.73E-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 TH-234 2.08E-02 1.OOE-02 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 RA-226 1.32E-03 1.11E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 PB-214 2.10E-03 1.08E-03 204 22.4 MI NNE -SUTTON PLANT (CONTROL) 11/16/2009 3631.2 BI-214 2.45E-03 1.25E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 PB-212 2.36E-03 1.09E-03 204 22.4 MI NNE - SUTTON PLANT (CONTROL) 11/16/2009 3631.2 K-40 4.82E-02 1.10E-02 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 BI-214 2.81 E-03 1.19E-03 Page 5 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Air Particulate Quantity:. CUBIC METERS Concentration (Activiti).: pCi/cubic meter Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 PB-212 1.04E-03 7.59E-04 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 PB-214 4.04E-03 1.17E-03 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 RA-226 1.37E-02 8.53E-03 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 BE-7 1.69E-01 2.02E-02 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 K-40 4.04E-02 8.88E-03 205 0.6 MI SSE - SPOIL POND 2/16/2009 3738.1 TH-234 1.42E-02 8.80E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 K-40 3.44E-02 7.39E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 BE-7 1.39E-01 1.73E-02 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 PB-212 8.98E-04 6.01E-04 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 BI-214 6.95E-03 1.47E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 PB-214 7.OOE-03 1.37E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 RA-226 1.29E-02 8.39E-03 205 0.6 MI SSE - SPOIL POND 5/18/2009 3841.6 TH-234 1.23E-02 9.52E-03 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 BE-7 1.15E-01 1.71E-02 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 TH-234 1.44E-02 1.06E-02 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 RA-226 2.23E-02 1.33E-02 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 B1-214 2.61E-03 1.10E-03 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 PB-212 1.15E-03 8.06E-04 205 0.6 MI SSE - SPOIL POND 8/17/2009 3663.8 K-40 5.1OE-02 9.94E-03 205 0.6 MI SSE - SPOIL POND 11/16/2009 3589 BE-7 1.03E-01 1.61 E-02 205 0.6 MI SSE - SPOIL POND 11/16/2009 3589 BI-214 4.45E-03 1.62E-03 205 0.6 MI SSE - SPOIL POND 11/16/2009 3589 PB-212 1.45E-03 6.83E-04 205 0.6 MI SSE - SPOIL POND 11/16/2009 3589 TL-208 6.49E-04 4.33E-04 205 0.6 MI SSE - SPOIL POND 11/16/2009 3589 K-40 2.13E-02 7.48E-03 Page 6 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report lAediu Type: Air Particulate Quanti,'y: CUBIC METERS Concentration (Activitv): pCi/cubic meer Sample Point Sample Date 205 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 0.6 MI SSE - SPOIL POND 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11.3 MILES NW FROM PLANT AT BRUNSWICK COUNTY GOV 11/16/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 5/18/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 8/17/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 Quantity 3589 3422.7 3422.7 3422.7 3422.7 3422.7 3422.7 3665.7 3665.7 3665.7 3665.7 3665.7 3565.2 3565.2 3565.2 3565.2 3565.2 3565.2 3565.2 Isotope PB-214 BE-7 PB-212 RA-226 BI-214 PB-214 K-40 BE-7 K-40 PB-212 BI-214 RA-226 K-40 TL-208 PB-212 BI-214 RA-226 TH-234 BE-7 Activity 6.20E-03 1.27E-01 1.31E-03 1.76E-02 8.OOE-03 9.67E-03 2.93E-02 1.32E-01 6.87E-02 1.04E-03 2.16E-03 1.22E-02 5.20E-02 6.60E-04 1.OOE-03 2.81 E-03 1.20E-02 1.57E-02 9.94E-02 2 Sigmia Error 1.37E-03 1.85E-02 7.63E-04 8.65E-03 2.02E-03 1.73E-03 9.09E-03 1.85E-02 1.28E-02 7.27E-04 1.14E-03 1.OOE-02 1.1 8E-02 4.96E-04 9.70E-04 1.47E-03 1.14E-02 9.21 E-03 1.58E-02 Page 7 of 7
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (Activil'v). pCi/gm wet Media:
CHERRY Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 PB-212 5.11E-02 3.35E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 BE-7 1.21 E+00 2.27E-01 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 K-40 3.27E+00 4.78E-01 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 TH-234 6.99E-01 5.77E-01 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 TL-208 1.82E-02 1.43E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 RA-226 9.15E-01 4.29E-01 803 0.6 MI SSE - SPOIL POND 10/1/2009 443.7 BI-214 4.72E-02 2.98E-02 Page I of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadlca' Vegetation Quantity.: GRA MS (wet)
Concentration (Activia;): pCi/gm wet Mledia:
SWEETGUM Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 480.4 BE-7 2.09E+00 3.20E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 480.4 K-40 3.71E+00 6.49E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 480.4 PB-212 5.26E-02 2.89E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 480.4 BI-214 6.07E-02 4.92E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 480.4 RA-226 6.04E-01 5.17E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 PB-214 9.70E-02 3.94E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 BI-214 1.12E-01 3.93E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 PB-212 1.28E-01 3.56E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 K-40 1.96E+00 3.69E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 BE-7 2.16E+00 2.78E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 TL-208 4.14E-02 2.21E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 476.6 RA-226 5.56E-01 3.22E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 PB-214 8.86E-02 3.26E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 RA-226 5.55E-01 2.68E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 BI-214 8.07E-02 4.33E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 TH-234 5.46E-01 3.92E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 BE-7 2.94E+00 2.82E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 K-40 2.76E+00 3.34E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 TL-208 3.74E-02 1.43E-02 Page 2 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRA MS (wet)
Concentration (Activify,): pCilgm wet Media:
SWEETGUM Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 12/1/2009 425.1 PB-212 8.73E-02 2.57E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 K-40 2.32E+00 2.89E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 RA-226 3.89E-01 3.24E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 PB-214 4.73E-02 2.38E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 TL-208 1.90E-02 1.16E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 BE-7 2.17E+00 2.23E+00 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 558.3 BI-214 6.32E-02 2.05E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 PB-214 1.36E-01 3.07E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 TH-234 5.89E-01 4.13E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 BE-7 1.11E+00 1.73E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 K-40 2.11 E+00 2.71 E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 TL-208 1.93E-02 9.55E-03 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 PB-212 7.80E-02 2.06E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 468.1 BI-214 1.65E-01 3.62E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 RA-226 3.28E-01 2.49E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 BI-214 6.17E-02 2.83E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 PB-212 5.19E-02 2.33E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 TL-208 2.92E-02 1.51 E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 K-40 1.61E+00 2.44E-01 Page 3 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRA MS (wet)
Concentration (Activity): pCi/gm wet Media:
SWEETGUM Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 433.7 BE-7 1.22E+00 1.75E-01 Page 4 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (Activity,): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 800 0.7 MI NE - INTAKE CANAL 1/1/2009 536.2 K-40 3.14E+00 5.11E-01 800 0.7 MI NE - INTAKE CANAL 1/1/2009 536.2 BE-7 1.31E+00 2.47E-01 800 0.7 MI NE - INTAKE CANAL 1/1/2009 536.2 BI-214 5.49E-02 3.74E-02 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 BE-7 1.79E+00 2.06E-01 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 K-40 2.36E+00 3.02E-01 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 PB-212 3.05E-02 1.74E-02 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 RA-226 6.59E-01 3.09E-01 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 PB-214 1.08E-01 2.89E-02 800 0.7 MI NE - INTAKE CANAL 2/2/2009 489.2 BI-214 1.22E-01 2.98E-02 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 TH-234 4.05E-01 3.48E-01 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 BE-7 2.62E+00 2.27E-01 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 K-40 2.19E+00 2.50E-01 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 PB-212 3.38E-02 1.48E-02 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 PB-214 1.96E-02 1.81 E-02 800 0.7 MI NE - INTAKE CANAL 3/1/2009 670.4 BI-214 2.67E-02 1.43E-02 800 0.7 MI NE - INTAKE CANAL 4/1/2009 565.4 K-40 1.91E+00 2.53E-01 800 0.7 MI NE - INTAKE CANAL 4/1/2009 565.4 PB-212 3.48E-02 1.74E-02 800 0.7 MI NE - INTAKE CANAL 4/1/2009 565.4 BI-214 8.50E-02 2.53E-02 800 0.7 MI NE - INTAKE CANAL 4/1/2009 565.4 PB-214 5.33E-02 2.37E-02 Page 5 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broad/eaf Vegetation Quanti*y: GRAMS (wet)
Concentration (Activi1): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sihma Error 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 0.7 MI NE - INTAKE CANAL 4/1/2009 4/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 565.4 565.4 605.9 605.9 605.9 605.9 605.9 605.9 483.7 483.7 483.7 483.7 483.7 483.7 483.7 577.6 577.6 577.6 577.6 RA-226 BE-7 BE-7 K-40 TL-208 PB-214 BI-214 PB-212 PB-212 RA-226 PB-214 TH-234 K-40 BE-7 TL-208 RA-226 BE-7 K-40 4.12E-01 2.17E+00 2.27E+00 2.90E+00 1.52E-02 4.58E-02 3.45E-02 3.02E-02 5.41 E-02 4.97E-01 5.75E-02 5.80E-01 3.35E+00 1.08E+00 2.73E-02 4.09E-01 9.45E-01 3.15E+00 2.79E-01 2.18E-01 2.19E-01 3.28E-01 8.48E-03 2.29E-02 2.02E-02 1.95E-02 2.35E-02 3.61E-01 3.59E-02 4.23E-01 4.51 E-01 2.06E-01 1.94E-02 2.31E-01 1.41 E-01 3.30E-01 2.45E-02 Page 6 of 25 BI-214 9.15E-02
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Tyvpe: Broad/eqf Vegetation Quantity: GRAMS (vet)
Concentration (Activity): pCiigm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 800 0.7 MI NE - INTAKE CANAL 7/1/2009 577.6 PB-214 4.86E-02 2.48E-02 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 TL-208 7.95E-03 7.36E-03 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 PB-212 3.73E-02 1.62E-02 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 K-40 2.76E+00 2.93E-01 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 BE-7 1.08E+00 1.41 E-01 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 BI-214 1.39E-01 2.83E-02 800 0.7 MI NE - INTAKE CANAL 8/1/2009 571.7 PB-214 1.14E-01 3.25E-02 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 TH-234 1.22E+00 5.98E-01 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 PB-212 6.63E-02 2.52E-02 800" 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 RA-226 4.57E-01 2.79E-01 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 BI-214 5.18E-02 3.84E-02' 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 TL-208 3.06E-02 1.99E-02 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 K-40 3.36E+00 3.80E-01 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 BE-7 1.49E+00 1.96E-01 800 0.7 MI NE - INTAKE CANAL 9/1/2009 407.5 PB-214 8.25E-02 3.90E-02 800 0.7 MI NE - INTAKE CANAL 10/1/2009 424 K-40 4.76E+00 6.66E-01 800 0.7 MI NE - INTAKE CANAL 10/1/2009 424 PB-212 7.06E-02 4.84E-02 800 0.7 MI NE - INTAKE CANAL 10/1/2009 424 TL-208 3.59E-02 2.67E-02 800 0.7 MI NE - INTAKE CANAL 10/1/2009 424 BI-214 1.05E-01 5.80E-02 Page 7 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantily: GRAMS (wet)
Concentration (Activia*): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error A
800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 800 0.7 MI NE - INTAKE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 10/1/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 1/1/2009 1/1/2009 424 391.4 391.4 391.4 391.4 391.4 391.4 391.4 391.4 421 421 421 421 421 421 421 421 465 465 BE-7 BI-214 TH-234 PB-214 1.43E+00 2.21 E-01 9.94E-01 1.44E-01 PB-212 7.01 E-02 TL-208 2.54E-02 K-40 BE-7 RA-226 BI-214 PB-214 BE-7 RA-226 K-40 TH-234 TL-208 PB-212 BI-214 K-40 2.45E+00 1.49E+00 7.13E-01 9.27E-02 8.12E-02 2.02E+00 8.77E-01 2.06E+00 1.01E+00 3.96E-02 5.65E-02 1.06E-01 3.04E+00 3.07E-01 4.75E-02 4.82E-01 3.86E-02 2.49E-02 1.77E-02 3.62E-01 2.06E-01 3.28E-01 3.50E-02 4.49E-02 2.83E-01 3.66E-01 4.37E-01 6.07E-01 1.56E-02 3.70E-02 4.52E-02 5.75E-01 Page 8 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleuf Vegetation Quantiy: GRA MS (wet)
Concentration (Activiti): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 801 0.8 MI SW - DISCHARGE CANAL 1/1/2009 465 BE-7 1.86E+00 3.65E-01 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 BI-214 7.74E-02 2.22E-02 801 0.8 MI SW-DISCHARGE CANAL 2/2/2009 524.5 PB-212 4.03E-02 1.68E-02 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 TL-208 1.42E-02 1.OOE-02 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 K-40 2.35E+00 2.86E-01 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 PB-214 6.78E-02 2.54E-02 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 RA-226 6.24E-01 2.60E-01 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 TH-234 4.88E-01 3.67E-01 801 0.8 MI SW - DISCHARGE CANAL 2/2/2009 524.5 BE-7 2.75E+00 2.55E-01 801 0.8 MI SW - DISCHARGE CANAL 3/1/2009 579.3 BE-7 1.15E+00 1.46E-01 801 0.8 MI SW - DISCHARGE CANAL 3/1/2009 579.3 TH-234 4.72E-01 3.06E-01 801 0.8 MI SW-DISCHARGE CANAL 3/1/2009 579.3 RA-226 2.97E-01 1.84E-01 801 0.8 MI SW - DISCHARGE CANAL 3/1/2009 579.3 BI-214 4.39E-02 1.98E-02 801 0.8 MI SW-DISCHARGE CANAL 3/1/2009 579.3 PB-212 2.90E-02 1.49E-02 801 0.8 MI SW - DISCHARGE CANAL 3/1/2009 579.3 K-40 1.95E+00 2.38E-01 801 0.8 MI SW - DISCHARGE CANAL 3/1/2009 579.3 TL-208 1.59E-02 9.03E-03 801 0.8 MI SW - DISCHARGE CANAL 4/1/2009 525.3 PB-214 3.29E-02 2.29E-02 801 0.8 MI SW - DISCHARGE CANAL 4/1/2009 525.3 BI-214 5.77E-02 2.43E-02 801 0.8 MI SW - DISCHARGE CANAL 4/1/2009 525.3 K-40 2.46E+00 2.98E-01 Page 9 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report A'fedia Type.: Broadleuf Vegetation Quantity: GRA MS (wet)
Concentration (Activitv): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sizima Error 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 801 0.8 MI SW - DISCHARGE CANAL 4/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/6/2009 5/6/2009 5/6/2009 5/6/2009 5/6/2009 5/6/2009 5/6/2009 6/1/2009 6/1/2009 6/1/2009 525.3 605.7 605.7 605.7 605.7 605.7 605.7 605.7 605.7 543.7 543.7 543.7 543.7 543.7 543.7 543.7 544.4 544.4 544.4 BE-7 1.43E+00 BI-214 3.44E-02 PB-214 RA-226 TH-234 BE-7 K-40 CO-60 PB-212 BE-7 K-40 CO-60 RA-226 TL-208 PB-212 BI-214 BE-7 K-40 TL-208 4.67E-02 3.86E-01 5.53E-01 7.93E-01 2.20E+00 7.57E-02 3.04E-02 7.51 E-01 3.03E+00 2.31 E-02 4.82E-01 1.56E-02 6.72E-02 4.87E-02 9.57E-01 5.08E+00 2.63E-02 1.78E-01 1.97E-02 1.96E-02 2.36E-01 3.37E-01 1.32E-01 2.71 E-01 1.52E-02 1.20E-02 1.25E-01 3.25E-01 1.82E-02 2.30E-01 1.12E-02 2.08E-02 2.58E-02 2.11E-01 5.96E-01 1.75E-02 Page 10 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quawtity: GRAMS (wet)
Concentration (Activili): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Ouantitv Isotope Activity 2 Siema Error 801 801 801 801 801 801 801 801 801 801 801 801 801 801 801 801 801 801 801 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 0.8 MI SW - DISCHARGE CANAL 6/1/2009 7/1/2009 7/1/2009 7/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 9/1/2009 9/1/2009 9/1/2009 9/1/2009 9/1/2009 9/1/2009 10/1/2009 10/1/2009 10/1/2009 544.4 588.1 588.1 588.1 569.6 569.6 569.6 569.6 569.6 569.6 412.8 412.8 412.8 412.8 412.8 412.8 557.3 557.3 557.3 PB-212 K-40 BI-214 BE-7 BE-7 K-40 PB-212 BI-214 RA-226 TH-234 PB-212 RA-226 K-40 BI-214 PB-214 BE-7 BI-214 BE-7 PB-214 3.82E-02 3.25E+00 4.77E-02 7.80E-01 1.15E+00 2.52E+00 4.22E-02 5.21 E-02 1.96E-01 4.48E-01 1.03E-01 4.99E-01 3.19E+00 1.19E-01 8.97E-02 9.07E-01 1.61E-01 1.29E+00 8.40E-02 3.04E-02 3.51 E-01 2.02E-02 1.31E-01 1.57E-01 2.84E-01 1.87E-02 2.11E-02 1.75E-01 2.99E-01 4.54E-02 4.32E-01 5.08E-01 5.67E-02 4.03E-02 2.13E-01 3.03E-02 1.69E-01 2.35E-02 Page 11 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaj'Vegetation Quantiy: GRAMS (wet)
Concentration (Activia;): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 801 0.8 MI SW-DISCHARGE CANAL 10/1/2009 557.3 TL-208 1.98E-02 1.32E-02 801 0.8 MI SW - DISCHARGE CANAL 10/1/2009 557.3 K-40 3.01 E+00 3.24E-01 801 0.8 MI SW - DISCHARGE CANAL 10/1/2009 557.3 PB-212 5.14E-02 1.91 E-02 801 0.8 MI SW - DISCHARGE CANAL 11/2/2009 443.9 BE-7 2.32E+00 2.54E-01 801 0.8 MI SW - DISCHARGE CANAL 11/2/2009 443.9 TL-208 2.95E-02 1.80E-02 801 0.8 MI SW-DISCHARGE CANAL 11/2/2009 443.9 PB-212 4.97E-02 3.47E-02 801 0.8 MI SW-DISCHARGE CANAL 11/2/2009 443.9 BI-214 1.08E-01 3.23E-02 801 0.8 MI SW - DISCHARGE CANAL 11/2/2009 443.9 PB-214 1.15E-01 3.44E-02 801 0.8 MI SW-DISCHARGE CANAL 11/2/2009 443.9 RA-226 5.75E-01 3.67E-01 801 0.8 MI SW-DISCHARGE CANAL 11/2/2009 443.9 AC-228 1.36E-01 4.57E-02 801 0.8 MI SW-DISCHARGE CANAL 11/2/2009 443.9 TH-234 6.46E-01 5.02E-01 801 0.8 MI SW - DISCHARGE CANAL 11/2/2009 443.9 K-40 3.06E+00 3.74E-01 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 PB-214 8.94E-02 2.53E-02 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 BE-7 8.75E-01 1.46E-01 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 K-40 2.43E+00 2.87E-01 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 TL-208 2.35E-02 1.34E-02 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 PB-212 7.85E-02 2.20E-02 801 0.8 MI SW-DISCHARGE CANAL 12/1/2009 504.7 RA-226 3.73E-01 2.31E-01 801 0.8 MI SW - DISCHARGE CANAL 12/1/2009 504.7 BI-214 8.90E-02 3.16E-02 Page 12 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Tvpe. Broadleg/ Vegetion Quantity: GRAMS (,we)
Concentration (Activity): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Siema Error 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 10.1 MI.- (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 1/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 3/1/2009 3/1/2009 3/1/2009 3/1/2009 468.2 468.2 468.2 468.2 468.2 468.2 468.2 468.2 505.1 505.1 505.1 505.1 505.1 505.1 505.1 435.3 435.3 435.3 435.3 PB-214 8.07E-02 BE-7 2.02E+00 TH-234 6.22E-01 K-40 1.88E+00 RA-226 5.45E-01 BI-214 1.15E-01 PB-212 5.45E-02 TL-208 2.10E-02 BI-214 6.71E-02 BE-7 2.32E+00 PB-212 4.72E-02 PB-214 4.29E-02 RA-226 5.59E-01 TL-208 2.OOE-02 K-40 1.42E+00 BE-7 2.05E+00 RA-226 5.78E-01 K-40 2.16E+00 PB-212 6.68E-02 3.33E-02 2.70E-01 5.87E-01 3.33E-01 3.68E-01
.3.41 E-02 3.23E-02 1.78E-02 3.01 E-02 2.17E-01 2.34E-02 2.33E-02 3.11E-01 1.18E-02 2.51 E-01 2.93E-01 3.46E-01 3.67E-01 3.12E-02 Page 13 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleitf Vegetation Quantify: GRAMS (wet)
Concentration (Activiry): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 3/1/2009 435.3 TL-208 2.17E-02 1.97E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 3/1/2009 435.3 BI-214 7.88E-02 4.82E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 RA-226 4.92E-01 3.37E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 BE-7 3.96E+00 3.81 E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 K-40 1.65E+00 3.58E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 BI-214 1.65E-01 5.08E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 TL-208 3.85E-02 1.89E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 PB-212 5.37E-02 2.55E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 4/1/2009 502 PB-214 1.34E-01 4.75E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 BI-214 3.78E-02 1.84E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 TL-208 2.14E-02 8.96E-03 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 PB-214 3.23E-02 2.06E-02 802 10.1 MI -(CONTROL)-
LOCATION NOT SPECIFIED 5/1/2009 557.7 K-40 3.01E+00 2.97E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 RA-226 3.83E-01 1.83E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 TH-234 4.91E-01 2.88E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 BE-7 1.39E+00 1.51 E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 5/1/2009 557.7 PB-212 3.58E-02 1.42E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 6/1/2009 559.2 K-40 2.71E+00 3.OOE-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 6/1/2009 559.2 CS-137 1.78E-02 1.08E-02 Page 14 of'25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRAMS (we0)
Concentration (4ctivil,)." pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL.) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 559.2 559.2 559.2 559.2 559.2 559.2 559.2 530.6 530.6 530.6 530.6 530.6 530.6 530.6 530.6 596.8 596.8 596.8 596.8 TL-208 1.50E-02 PB-212 3.81 E-02 BI-214 5.46E-02 PB-214 3.25E-02 RA-226 3.83E-01 AC-228 9.64E-02 BE-7 1.06E+00 TL-208 1.66E-02 PB-212 5.55E-02 BI-214 1.16E-01 PB-214 8.OOE-02 RA-226 3.08E-01 AC-228 1.01E-01 BE-7 1.24E+00 K-40 2.58E+00 BE-7 6.94E-01 TH-234 4.37E-01 RA-226 3.74E-01 BI-214 4.01 E-02 9.32E-03 1.38E-02 1.96E-02 2.13E-02 3.05E-01 3.69E-02 1.43E-01 9.45E-03 1.99E-02 2.94E-02 2.71 E-02 2.06E-01 4.51 E-02 1.63E-01 3.10E-01 1.13E-01 3.44E-01 2.17E-01 1.76E-02 Page 15 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type.: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (Activity)." pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 8/1/2009 596.8 PB-212 3.12E-02 1.91E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 8/1/2009 596.8 CS-137 1.60E-02 1.07E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 8/1/2009 596.8 K-40 1.95E+00 2.48E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 TH-234 4.79E-01 3.68E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 BE-7 1.03E+00 1.44E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 K-40 2.49E+00 3.OOE-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 PB-212 4.65E-02 2.63E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 BI-214 4.95E-02 2.48E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 PB-214 6.32E-02 2.57E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 9/1/2009 494.2 RA-226 4.31E-01 2.89E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 RA-226 7.56E-01 3.77E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 BI-214 7.79E-02 4.45E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 TL-208 3.33E-02 1.84E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 K-40 2.54E+00 4.44E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 BE-7 1.80E+00 2.97E-01 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 AC-228 1.37E-01 5.21E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 10/1/2009 439.9 PB-212 9.60E-02 3.54E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 465.3 AC-228 1.42E-01 4.83E-02 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 11/2/2009 465.3 K-40 2.75E+00 3.32E-01 Page 16 of25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: BroadleIa Vegetation Quantity: GRAMS (wet)
Concentration (Activity): pCi/gm wel Media:
WAX MYRTLE Sample Point Sanple Date Ouantitv Isotope Activity 2 Sizmna Error 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 802 10.1 MI - (CONTROL) - LOCATION NOT SPECIFIED 803 0.6 MI SSE - SPOIL POND 803 0.6 MI SSE - SPOIL POND 803 0.6 MI SSE - SPOIL POND 803 0.6 MI SSE - SPOIL POND 803 0.6 MI SSE - SPOIL POND 11/2/2009 11/2/2009 11/2/2009 11/2/2009 11/2/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 12/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 2/2/2009 465.3 465.3 465.3 465.3 465.3 432.9 432.9 432.9 432.9 432.9 432.9 432.9 432.9 432.9 459.3 459.3 459.3 459.3 524.7 BE-7 TL-208 2.61 E+00 3.69E-02 BI-214 1.15E-01 PB-212 8.02E-02 PB-214 1.10E-01 TL-208 4.79E-02 TH-234 1.85E+00 PB-212 8.74E-02 PB-214 9.88E-02 K-40 2.65E+00 BE-7 1.88E+00 RA-226 5.09E-01 AC-228 1.43E-01 BI-214 1.11E-01 BI-214 6.21E-02 BE-7 1.65E+00 K-40 4.48E+00 PB-212 6.23E-02 TH-234 4.98E-01 2.63E-01 1.69E-02 3.37E-02 2.69E-02 3.60E-02 2.20E-02 8.06E-01 3.52E-02 5.07E-02 4.24E-01 2.94E-01 4.41E-01 6.31 E-02 5.03E-02 4.49E-02 3.18E-01 5.95E-01 2.76E-02 3.29E-01 Page 17 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type.: Broadeaf' Vegetation Quantitly. GRAMS (wet)
Concentration (Activit)): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/5/2009 2/5/2009 2/5/2009 2/5/2009 2/5/2009 2/5/2009 2/5/2009 3/1/2009 3/1/2009 3/1/2009 3/11/2009 3/1/2009 524.7 524.7 524.7 524.7 524.7 524.7 524.7 501.2 501.2 501.2 501.2 501.2 501.2 501.2 607.3 607.3 607.3 607.3 607.3 PB-214 PB-212 TL-208 CO-60 K-40 BE-7 BI-214 K-40 TL-208 PB-212 BI-214 RA-226 TH-234 BE-7 BE-7 TH-234 PB-212 K-40 PB-214 1.90E-02 4.51E-02 1.17E-02 2.63E-02 1.78E+00 1.27E+00 2.99E-02 2.95E+00 3.09E-02 5.77E-02 5.22E-02 4.28E-01 4.14E-01 1.29E+00 1.12E+00 5.67E-01 2.08E-02 1.91 E+00 3.31 E-02 1.49E-02 1.34E-02 1.03E-02 1.01E-02 2.44E-01 1.45E-01 2.15E-02 3.22E-01 1.44E-02 1.92E-02 2.08E-02 3.14E-01 3.37E-01 1.69E-01 1.44E-01 4.58E-01 1.34E-02 2.38E-01 2.02E-02 Page 18 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report AMJedia T.pe: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (4ctiviti): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantitv Isotope Activity 2 Sigma Error 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 803 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 3/1/2009 3/1/2009 3/1/2009 4/1/2009 4/1/2009 4/1/2009 4/1/2009 4/1/2009 4/1/2009 4/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 607.3 607.3 607.3 654.2 654.2 654.2 654.2 654.2 654.2 654.2 582.7 582.7 582.7 582.7 582.7 577.9 577.9 577.9 577.9 TL-208 1.04E-02 RA-226 2.30E-01 BI-214 2.73E-02 TL-208 1.36E-02 BE-7 1.45E+00 PB-212 1.97E-02 BI-214 5.21E-02 RA-226 3.25E-01 TH-234 4.71E-01 K-40 1.76E+00 BE-7 1.09E+00 K-40 2.42E+00 PB-212 3.09E-02 BI-214 3.10E-02 9.12E-03 2.11E-01 2.15E-02 9.16E-03 1.60E-01 1.71E-02 2.12E-02 1.91 E-01 2.65E-01 2.14E-01 1.45E-01 2.90E-01 1.78E-02 1.63E-02 2.01E-01 2.01 E-02 3.19E-01 1.86E-02 2.50E-01 RA-226 PB-212 K-40 BI-214 RA-226 3.47E-01 3.74E-02 2.86E+00 3.69E-02 4.57E-01 Page 19 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (Activit'): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 803 0.6 MI SSE - SPOIL POND 6/1/2009 577.9 BE-7 9.82E-01 1.49E-01 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 K-40 3.12E+00 3.58E-01 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 BE-7 9.50E-01 1.48E-01 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 RA-226 3.42E-01 2.47E-01 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 PB-214 3.40E-02 2.56E-02 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 BI-214 6.51 E-02 2.91E-02 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 PB-212 3.43E-02 2.10E-02 803 0.6 MI SSE - SPOIL POND 7/1/2009 519.7 TL-208 1.34E-02 9.44E-03 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 BE-7 1.01E+00 2.31E-01 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 BI-214 1.18E-01 4.87E-02 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 PB-214 7.32E-02 3.35E-02 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 PB-212 4.53E-02 2.49E-02 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 RA-226 4.10E-01 3.14E-01 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 TH-234 8.83E-01 4.99E-01 803 0.6 MI SSE - SPOIL POND 8/1/2009 446 K-40 3.36E+00 4.66E-01 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 RA-226 5.50E-01 3.79E-01 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 "TH-234 8.16E-01 5.39E-01 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 BE-7 1.11E+00 2.65E-01 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 K-40 3.96E+00 5.40E-01 Page 20 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantivy: GRAMS (wet)
Concentration (Activirv): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 TL-208 3.52E-02 2.08E-02 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 PB-212 7.69E-02 3.55E-02 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 BI-214 1.63E-01 5.21 E-02 803 0.6 MI SSE - SPOIL POND 9/1/2009 419.2 PB-214 1.22E-01 4.41 E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 433.4 BE-7 1.54E+00 2.11E-01 803 0.6 MI SSE - SPOIL POND 10/1/2009 433.4 PB-212 4.82E-02 2.51 E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 433.4 BI-214 3.62E-02 3.11E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 433.4 PB-214 6.78E-02 3.75E-02 803 0.6 MI SSE - SPOIL POND 10/1/2009 433.4 K-40 3.97E+00 4.44E-01 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 BI-214 9.59E-02 3.76E-02 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 PB-214 8.74E-02 2.57E-02 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 PB-212 3.92E-02 2.34E-02 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 TL-208 1.64E-02 1.18E-02 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 K-40 2.83E+00 3.47E-01 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 BE-7 1.74E+00 2.15E-01 803 0.6 MI SSE - SPOIL POND 11/2/2009 454.3 RA-226 6.17E-01 2.34E-01 803 0.6 MI SSE - SPOIL POND 12/1/2009 404.5 BE-7 2.17E+00 3.35E-01 803 0.6 MI SSE - SPOIL POND 12/1/2009 404.5 K-40 2.50E+00 4.09E-01 803 0.6 MI SSE - SPOIL POND 12/1/2009 404.5 TL-208 2.86E-02 1.93E-02 Page 21 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report AMledia Type: Broadleaf" Vegetatibn Quantity: GRAMS (wet)
Concentration (Activiyv): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Ouantitv Isotope Activity 2 Sigma Error 803 803 803 804 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.6 MI SSE - SPOIL POND 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 12/1/2009 12/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 1/1/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 2/2/2009 3/1/2009 3/1/2009 3/1/2009 3/1/2009 4/1/2009 4/1/2009 404.5 404.5 404.5 484.7 484.7 484.7 484.7 484.7 534 534 534 534 534 506.9 506.9 506.9 506.9 647.2 647.2 PB-212 7.34E-02 BI-214 9.14E-02 RA-226 7.47E-01 RA-226 4.04E-01 TL-208 2.42E-02 K-40 2.22E+00 PB-212 5.04E-02 BE-7 PB-212 BE-7 PB-214 K-40 BI-214 BE-7 BI-214 PB-212 K-40 BE-7 K-40 1.63E+00 3.93E-02 2.20E+00 5.22E-02 2.34E+00 5.35E-02 1.64E+00 3.13E-02 3.02E-02 2.25E+00 1.72E+00 3.35E+00 3.58E-02 3.89E-02 4.37E-01 3.59E-01 1.97E-02 3.54E-01 2.62E-02 2.40E-01 1.68E-02 2.29E-01 2.71 E-02 3.03E-01 2.62E-02 1.81E-01 2.49E-02 1.73E-02 2.94E-01 2.52E-01 4.22E-01 Page 22 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report AMledia Type: Broadleaf Vegetation Quanti*y: GRAMS (wet)
Concentration (Activitv1: pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 804 804 804 804 804 804 804 804 804 804 804 804 804 804 804 804 804 804 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 5/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 6/1/2009 7/1/2009 7/1/2009 7/1/2009 7/1/2009 695.2 695.2 695.2 695.2 695.2 695.2 695.2 695.2 593.6 593.6 593.6 593.6 593.6 593.6 593.6 548.9 548.9 548.9 548.9 RA-226 2.54E-01 TL-208 1.40E-02 PB-212 2.65E-02 BI-214 5.30E-02 PB-214 3.33E-02 K-40 2.19E+00 BE-7 1.16E+00 TH-234 3.88E-01 PB-214 4.90E-02 PB-212 4.24E-02 BI-214 5.49E-02 BE-7 6.68E-01 K-40 2.54E+00 TL-208 2.07E-02 RA-226 5.07E-01 BI-214 7.13E-02 PB-212 2.93E-02 PB-214 5.11E-02 RA-226 2.76E-01 1.57E-01 9.80E-03 1.76E-02 1.85E-02 1.79E-02
.2.55E-01 1.41E-01 2.79E-01 2.78E-02 1.51E-02 2.38E-02 1.22E-01 2.80E-01 1.29E-02 2.17E-01 2.20E-02 2.41 E-02 3.34E-02 2.31 E-01 Page 23 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleaf Vegetation Quantity: GRAMS (wet)
Concentration (Activity): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Ouantitv Isotope Activity 2 Sienma Error 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET'PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 7/1/2009 7/1/2009 7/1/2009 7/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 8/1/2009 9/1/2009 9/1/2009 9/1/2009 9/1/2009 9/1/2009 10/1/2009 10/1/2009 10/1/2009 548.9 548.9 548.9 548.9 500.2 500.2 500.2 500.2 500.2 500.2 500.2 472.5 472.5 472.5 472.5 472.5 489.2 489.2 489.2 TH-234 5.22E-01 BE-7 TL-208 K-40 TH-234 BE-7 K-40 PB-212 BI-214 PB-214 RA-226 PB-212 RA-226 TH-234 K-40 BE-7 RA-226 BE-7 K-40 1.01E+00 1.94E-02 2.43E+00 8.63E-01 1.14E+00 2.25E+00 3.93E-02 4.55E-02 6.92E-02 4.27E-01 5.42E-02 4.30E-01 6.84E-01 2.93E+00 8.32E-01 3.64E-01 7.67E-01 2.01E+00 2.93E-01 1.58E-01 1.17E-02 2.74E-01 5.08E-01 2.09E-01 3.68E-01 3.44E-02 4.11E-02 3.89E-02 3.36E-01 2.23E-02 2.82E-01 3.38E-01 3.37E-01 1.51E-01 2.15E-01 1.25E-01 2.59E-01 Page 24 of 25
BNP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Broadleafl Vegetation Quantity: GRAMS (wet)
Concentration (Activity): pCi/gm wet Media:
WAX MYRTLE Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 489.2 PB-212 2.59E-02 1.53E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 489.2 PB-214 5.94E-02 2.38E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 489.2 TH-234 4.26E-01 3.36E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 10/1/2009 489.2 BI-214 4.79E-02 2.80E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 TL-208 2.09E-02 1.22E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 PB-212 4.29E-02 2.15E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 RA-226 3.10E-01 2.62E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 BI-214 6.31E-02 2.34E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 K-40 2.16E+00 2.73E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 TH-234 6.30E-01 3.39E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 11/2/2009 510.2 BE-7 6.63E-01 1.34E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 BI-214 2.72E-02 2.43E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 PB-212 5.09E-02 2.12E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 TL-208 2.23E-02 1.50E-02 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 K-40 2.48E+00 3.20E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 BE-7 8.08E-01 1.53E-01 804 0.7 MILES S - LEONARD STREET PLANT EXIT ADJ 12/1/2009 497.3 RA-226 2.74E-01 2.51E-01 Page 25 of 25
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Fish and Invertebrates QuantitY: G-lAS (wet)
Concentration (Activitv)." pCi/gm we/
Sample Point Sample Date 700 5.5 MI SSW - FREE SWIMMERS - ATLANTIC OCEAN AT DI 700 5.5 MI SSW - FREE SWIMMERS - ATLANTIC OCEAN AT DI 700 5.5 MI SSW - FREE SWIMMERS - ATLANTIC OCEAN AT DI 700 5.5 MI SSW - FREE SWIMMERS - ATLANTIC OCEAN AT DI 701 5.5 MI SSW - BOTTOM FEEDER - ATLANTIC OCEAN AT DI 701 5.5 MI SSW - BOTTOM FEEDER - ATLANTIC OCEAN AT DI 701 5.5 MI SSW - BOTTOM FEEDER - ATLANTIC OCEAN AT DI 701 5.5 MI SSW - BOTTOM FEEDER - ATLANTIC OCEAN AT DI 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 702 5.5 MI SSW - SH/BO* - ATLANTIC OCEAN AT DISCHARGE 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 703 FREE SWIMMERS - ATLANTIC OCEAN (CONTROL) 704 BOTTOM FEEDER - ATLANTIC OCEAN (CONTROL) 704 BOTTOM FEEDER - ATLANTIC OCEAN (CONTROL) 704 BOTTOM FEEDER - ATLANTIC OCEAN (CONTROL) 704 BOTTOM FEEDER - ATLANTIC OCEAN (CONTROL)
- Shellfish/Benthic Organisms 5/22/2009 10/22/2009 10/22/2009 10/22/2009 5/22/2009 10/22/2009 10/22/2009 10/22/2009 6/2/2009 6/2/2009 6/2/2009 6/2/2009 6/2/2009 10/22/2009 10/22/2009 10/22/2009 6/2/2009 6/2/2009 6/2/2009 10/27/2009 10/27/2009 10/27/2009 6/2/2009 6/2/2009 6/2/2009 10/27/2009 Quantity 700.2 760.6 760.6 760.6 677.4 708 708 708 585.5 585.5 585.5 585.5 585.5 788.7 788.7 788.7 882.4 882.4 882.4 548.1 548.1 548.1 946 946 946 570.6 Isotope K-40 BI-214 K-40 PB-214 K-40 K-40 BI-214 PB-214 BI-214 PB-212 PB-214 K-40 TL-208 K-40 BI-214 PB-214 PB-214 RA-226 K-40 K-40 BI-214 PB-214 BI-214 K-40 PB-214 PB-214 Activity 4.99E+00 6.05E-02 4.02E+00 5.50E-02 3.38E+00 4.27E+00 1.25E-01 1.31 E-01 6.94E-02 4.65E-02 8.52E-02 3.08E+00 2.55E-02 3.63E+00 5.08E-02 1.10E-01 5.49E-02 3.80E-01 3.72E+00 3.39E+00 6.84 E-02 9.85E-02 6.42E-02 3.38E+00 4.47E-02 2.96E-01 2 Sigma Error 6.93E-01 3.98E-02 6.05E-01 3.87E-02 6.06E-01 6.10E-01 5.13E-02 4.65E-02 4.44E-02 3.21 E-02 5.09E-02 5.77E-01 2.09E-02 5.37E-01 4.43E-02 3.85E-02 2.43E-02 2.40E-01 5.57E-01 6.33E-01 3.85E-02 5.20E-02 2.28E-02 4.85E-01 3.19E-02 6.18E-02 Page 1 of 2
BSEP Radiological Environmental Monitoring Gamma Isotopic Report AM!edia Type: Fih and Invertebrates QuantitV: GRAI.S (wet)
Concentration (Activity): pCi/gm wet Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 704 BOTTOM FEEDER -ATLANTIC OCEAN (CONTROL) 10/27/2009 570.6 BI-214 2.11 E-01 6.59E-02 704 BOTTOM FEEDER - ATLANTIC OCEAN (CONTROL) 10/27/2009 570.6 K-40 2.83E+00 5.97E-01 705 SH/BO* - ATLANTIC OCEAN (CONTROL) 6/2/2009 562.9 K-40 3.18E+00 5.98E-01 705 SH/BO* - ATLANTIC OCEAN (CONTROL) 6/2/2009 562.9 BI-214 6.54E-02 4.64E-02 705 SH/BO* - ATLANTIC OCEAN (CONTROL) 10/27/2009 592.8 PB-214 4.83E-02 3.87E-02 705 SH/BO* - ATLANTIC OCEAN (CONTROL) 10/27/2009 592.8 PB-212 3.02E-02 2.26E-02 705 SH/BO* - ATLANTIC OCEAN (CONTROL) 10/27/2009 592.8 K-40 2.38E+00 5.04E-01 706 NANCY'S CREEK-FREE SWIMMERS 9/30/2009 1455 K-40 3.94E+00 707 NANCY'S CREEK - BOTTOM FEEDERS 9/30/2009 1699 K-40 3.49E+00 708 NANCY'S CREEK - SH/BO*
9/30/2009 2150 K-40 2.20E+00
- Shelijisli/Benthic Organisms Page 2 of 2
- ShelyishlBenthic Organisms Page 2 of 2
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Ty:pe: Shoreline Sediment Quantilv.: GRA AS (dt))
Concentration (Activiýv)." pCi/gm div Sample Point Sample Date 500 500 500 500 500 500 500 500 500 500 500 500 500 501 501 501 501 501 501 501 501 501 501 501 501 501 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS 5.0 MI SSW - DISCHARGE; BEACH NEAR OD PUMPS NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR.
NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/21/2009 5/21/2009 5/21/2009 5/21/2009 5/21/2009 5/21/2009 5/21/2009 10/26/2009 10/26/2009 10/26/2009 10/26/2009 10/26/2009 10/26/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 1/14/2009 5/1/2009 5/1/2009 Quantity 1384 1384 1384 1384 1384 1384 1384 1565.7 1565.7 1565.7 1565.7 1565.7 1565.7 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 1061.4 761.3 761.3 Isotope AC-228 RA-226 PB-214 BI-214 PB-212 TL-208 K-40 AC-228 TL-208 PB-212 PB-214 K-40 BI-214 BE-7 K-40 CS-137 TL-208 BI-212 PB-212 BI-214 PB-214 TH-234 RA-226 AC-228 AC-228 RA-226 Activity 9.88E-02 4.52E-01 1.87E-01 2.06E-01 1.35E-01 6.06E-02 3.19E+00 7.12E-02 3.35E-02 1.21E-01 2.89E-01 1.73E+00 1.93E-01 4.98E-01 9.97E+00 1.44E-01 2.04E-01 3.22E-01 5.66E-01 4.27E-01 4.67E-01 2.07E+00 2.04E+00 5.69E-01 4.99E-01 2.87E+00 2 Sigma Error 5.60E-02 2.71E-01 4.66E-02 4.30E-02 2.92E-02 2.09E-02 4.30E-01 4.86E-02 1.24E-02 2.46E-02 4.86E-02 2.80E-01 4.03E-02 1.69E-01 7.78E-01 3.07E-02 3.01E-02 1.23E-01 5.83E-02 5.72E-02 6.07E-02 7.84E-01 4.78E-01 9.61 E-02 1.78E-01 8.46E-01 Page I of 2
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Shoreline Sediment Quantit,: GS.
RAMS (d3y)
Concentration (Activity,1: pCi/gm dcv Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 PB-214 4.92E-01 9.14E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 K-40 9.88E+00 1.12E+00 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 BI-214 4.67E-01 1.01 E-01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 PB-212 5.52E-01 7.76E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 BI-212 3.81E-01 2.50E-01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 TH-234 4.08E+00 1.71E+00 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 CS-137 2.03E-01 4.31 E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 5/1/2009 761.3 TL-208 2.OOE-01 5.67E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 BI-214 3.94E-01 7.87E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 K-40 9.43E+00 9.64E-01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 CS-137 1.48E-01 3.35E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 TL-208 1.70E-01 3.81E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 PB-212 5.86E-01 8.22E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 PB-214 4.45E-01 8.43E-02 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 RA-226 1.61E+00 8.89E-01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 AC-228 5.04E-01 1.24E-01 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 TH-234 1.52E+00 1.13E+00 501 NANCY'S CREEK ADJACENT TO WP-55 NEAR STORM DR 12/21/2009 1027.9 BI-212 4.75E-01 2.24E-01 Page 2 of 2
BSEP Radiological Environmental Monitoring Gamma Isotopic Report kMedia Type: Surace Watler Quantfitv: Liters Concentration (Activit*): pCi/L Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error Sample Point Sample Date 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 0.6 M1 NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 1/17/2009 1/17/2009 1/17/2009 1/17/2009 1/17/2009 1/17/2009 1/17/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 PB-212 TL-208 BI-214 PB-214 RA-226 TH-234 K-40 BI-214 PB-212 TL-208 K-40 PB-214 RA-226 TH-234 TL-208 RA-226 K-40 PB-212 BI-214 PB-214 TH-234 RA-226 PB-214 PB-212 TL-208 BI-214 1.01 E+01 6.33E+00 1.20E+01 9.44E+00 1.19E+02 1.56E+02 3.41E+02 1.11E+01 1.58E+01 6.71 E+00 6.52E+02 8.41 E+00 1.70E+02 2.89E+02 3.72E+00 2.40E+02 4.17E+02 1.01E+01 1.82E+01 1.77E+01 2.04E+02 1.94E+02 1.61E+01 8.60E+00 3.14E+00 1.63E+01 2.32E+00 2.16E+00 4.57E+00 3.44E+00 3.39E+01 6.35E+01 3.84E+01 4.93E+00 3.15E+00 2.35E+00 5.24E+01 3.42E+00 4.75E+01 6.56E+01 1.54E+00 5.10E+01 3.99E+01 2.79E+00 4.13E+00 5.24E+00 7.12E+01 4.52E+01 4.47E+00 3.03E+00 1.92E+00 4.38E+00 Page 1 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Mfedia Type: Suifaice Writer Quantity: Liters Concentration M4ctivi.y)." pCi/L Sample Point Sample Date
- Ouantit, Isotope Activity 2 Sigma Error Sample Point Sample Date 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 4/16/2009 4/16/2009 5116/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 7/16/2009 7/16/2009 7/16/2009 7/16/2009 7/16/2009 7/16/2009 7/16/2009 7/16/2009 8/16/2009 TH-234 K-40 TL-208 AC-228 K-40 RA-226 PB-214 TH-234 BI-214 PB-212 K-40 BI-214 PB-212 PB-214 TH-234 TL-208 RA-226 TL-208 PB-212 BI-214 PB-214 RA-226 AC-228 TH-234 K-40 K-40 2.04E+02 4.02E+02 3.43E+00 9.85E+00 7.21 E+02 1.32E+02 9.10E+00 1.02E+02 1.19E+01 7.90E+00 7.55E+02 2.27E+01 7.03E+00 1.32E+01 1.27E+02 3.05E+00 1.13E+02 5.55E+00 1.05E+01 1.19E+01 1.10E+01 1.28E+02 8.OOE+00 1.21E+02 7.77E+02 7.99E+02 7.05E+01 4.01E+01 1.66E+00 7.73E+00 6.04E+01 4.93E+01 3.83E+00 6.36E+01 4.91E+00 3.27E+00 6.23E+01 5.30E+00 3.39E+00 4.69E+00 7.13E+01 2.46E+00 4.43E+01 2.1OE+00 3.30E+00 4.37E+00 3.84E+00 4.53E+01 5.93E+00 7.05E+01 6.28E+01 6.78E+01 Page 2 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Surface Water Quantitv." Liters Concentration (Activily)." pCi/L Sample Point Sample Date Quantitv Isotope Activity 2 Sigma Error Sample Point Sample Date 400 400 400 400 400 400 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 400 0.6 MI NE - INTAKE CANAL (CONTROL) 8/16/2009 8/16/2009 8/16/2009 8/16/2009 8/16/2009 9/16/2009 9/16/2009 9/16/2009 9/16/2009 9/16/2009 9/16/2009 10/16/2009 10/16/2009 10/16/2009 10/16/2009 10/16/2009 10/16/2009 10/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 TH-234 RA-226 BI-214 TL-208 PB-212 RA-226 1.69E+02 1.03E+02 1.07E+01 4.20E+00 8.87E+00 1.40E+02 1
1 1
1 BI-214 1.14E+01 TH-234 1.16E+02 K-40 7.42E+02 TL-208 6.07E+00 PB-212 1.12E+01 PB-212 7.99E+00 K-40 7.94E+02 TL-208 7.63E+00 TH-234 1.77E+02 BI-214 1.41E+01 RA-226 1.41E+02 PB-214 6.94E+00 BI-214 1.17E+01 TH-234 1.67E+02 AC-228 1.38E+01 RA-226 1.39E+02 PB-214 1.30E+01 PB-212 9.48E+00 K-40 7.78E+02 TL-208 2.94E+00 7.75E+01 4.94E+01 3.65E+00 2.14E+00 3.56E+00 4.38E+01 4.39E+00 7.15E+01 6.24E+01 2.50E+00 3.68E+00 3.27E+00 6.55E+01 2.49E+00 7.06E+01 4.30E+00 5.35E+0.1 3.99E+00 4.10E+00 7.09E+01 8.37E+00 4.51E+01 4.95E+00 3.86E+00 6.66E+01 2.03E+00 Page 3of7 400 400 400 400 400 400 400 400 400 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL)
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media T.ype.: Surjfce Water Quantity: Liters Concentration (Activity): pCi/L Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error Sample Point Sample Date 400 400 400 400 400 400 400 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 0.6 MI NE - INTAKE CANAL (CONTROL) 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 1/17/2009 1/17/2009 1/17/2009 1/17/2009 1/17/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 2/16/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 3/17/2009 PB-214 BI-214 PB-212 TL-208 K-40 RA-226 TH-234 K-40 TL-208 PB-212 BI-214 RA-226 PB-214 BI-214 RA-226 PB-212 TL-208 K-40 TH-234 K-40 TL-208 PB-212 BI-214 PB-214 RA-226 AC-228 5.84E+00 9.31E+00 9.36E+00 7.66E+00 6.58E+02 1.05E+02 1.02E+02 9.59E+02 4.75E+00 9.06E+00 1.02E+01 7.10E+01 6.64E+00 1.04E+01 1.64E+02 1.21E+01 6.08E+00 7.40E+02 1.50E+02 7.05E+02 3.47E+00 8.41E+00 9.68E+00 8.59E+00 1.21E+02 1.41E+01 4.38E+00 4.50E+00 3.59E+00 2.22E+00 5.61E+01 4.96E+01 7.09E+01 8.43E+01 2.85E+00 4.39E+00 6.27E+00 5.93E+01 5.17E+00 4.33E+00 5.69E+01 3.63E+00 2.30E+00 6.11E+01 7.78E+01 5.91 E+01 2.02E+00 3.68E+00 4.98E+00 4.26E+00 4.56E+01 6.94E+00 Page 4 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic Report iMfedia Tyvpe: Suiface Water Quantify: Liters Concentration (Activity): pCi/L Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error Sample Point Sample Date 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 3/17/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 4/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 5/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 6/16/2009 7/16/2009 7/16/2009 7/16/2009 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 TH-234 RA-226 TL-208 BI-212 PB-212 PB-214 K-40 1.06E+02 2.02E+02 4.75E+00 1.39E+01 1.39E+01 1.06E+01 5.85E+02 TH-234 2.60E+02 BI-214 TH-234 RA-226 PB-214 BI-214 PB-212 TL-208 9.87E+00 2.07E+02 1.72E+02 1.24E+01 1.01E+01 1.04E+01 3.61E+00 5.71E+01 4.62E+01 1.92E+00 1.35E+01 3.01E+00 4.12E+00 4.94E+01 7.06E+01 4.18E+00 7.08E+01 3.85E+01 3.81 E+00 3.92E+00 2.98E+00 1.70E+00 4.50E+01 4.25E+00 4.39E+01 6.36E+01 4.33E+00 3.06E+00 2.55E+00 4.35E+01 4.15E+00 7.89E+01 4.52E+00 Page 5 of 7 K-40 4.32E+02 BI-214 2.14E+01 K-40 4.86E+02 TH-234 1.99E+02 PB-214 PB-212 TL-208 RA-226 BI-214 TH-234 PB-214 1.85E+01 1.03E+01 5.04E+00 1.74E+02 1.88E+01 2.45E+02 1.63E+01
BSEP Radiological Environmental Monitoring Gamma Isotopic Report Media Type: Sur.ftce Water Quantit v: Liters Concentration (Activity): pCi/L Sample Point Sample Date Quantity Isotope Activity 2 Sigma Error 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 7/16/2009 1
PB-212 1.26E+01 3.06E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 7/16/2009 1
TL-208 3.74E+00 1.96E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 7/16/2009 1
K-40 5.34E+02 4.99E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 7/16/2009 1
RA-226 2.05E+02 4.58E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
PB-212 7.77E+00 3.23E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
K-40 5.48E+02 4.60E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
TL-208 3.18E+00 1.71 E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
TH-234 1.79E+02 7.11E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
RA-226 2.01 E+02 3.90E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
PB-214 1.28E+01 3.59E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 8/16/2009 1
BI-214 1.50E+01 4.85E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
RA-226 1.68E+02 4.44E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
TL-208 5.57E+00 2.14E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
PB-212 1.13E+01 3.OOE+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
PB-214 7.55E+00 3.59E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
TH-234 2.23E+02 6.57E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
BI-214 1.29E+01 4.59E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 9/16/2009 1
K-40 7.05E+02 5.62E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
PB-214 1.20E+01 3.98E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
K-40 4.84E+02 4.54E+01 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
TL-208 3.50E+00 1.81 E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
BI-214 1.25E+01 4.08E+00 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
RA-226 2.18E+02 4.50E+00 401 4.9 MI SSW-DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
TH-234 1.99E+02 7.OOE+01 401 4.9 MI SSW-DISCHARGE CANAL @ OD PUMPS 10/16/2009 1
PB-212 1.07E+01 3.05E+00 401 4.9 MI SSW-DISCHARGE CANAL @ OD PUMPS 11/16/2009 1
RA-226 1.74E+02 4.56E+01 Page 6 of 7
BSEP Radiological Environmental Monitoring Gamma Isotopic A'[edia Type: Suijtace Water Quantiry: Liters Concentration (4ctiviti." pCi/L Sample Point Sample Date Quantity Isotope Activity 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW-DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 401 4.9 MI SSW - DISCHARGE CANAL @ OD PUMPS 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 11/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 12/16/2009 1
K-40 4.57E+02 TH-234 PB-214 BI-214 TL-208 PB-212 TH-234 RA-226 PB-214 BI-214 PB-212 TL-208 K-40 1.81E+02 1.49E+01 1.92E+01 3.18E+00 8.61 E+00 2.32E+02 2.13E+02 8.16E+00 9.29E+00 6.96E+00 4.62E+00 3.90E+02 Report 2 Sigma Error 4.30E+01 6.40E+01 5.02E+00 4.14E+00 1.79E+00 2.53E+00 7.68E+01 4.41 E+01 3.89E+00 3.84E+00 2.72E+00 1.81 E+00 3.92E+01 Page 7 of 7