MONTHYEARML0932901092009-11-23023 November 2009 Request for Approval of Cyber Security Plan Project stage: Request ML1000800212010-01-11011 January 2010 Acceptance Review for License Amendment Request to Transition to Areva Fuel-Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2- Project stage: Acceptance Review ML1003409612010-02-23023 February 2010 Acceptance Review of Licensing Action Transition from Westinghouse to Areva Nuclear Fuel - Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 Project stage: Acceptance Review ML1007103192010-03-22022 March 2010 Request for Additional Information, Transition from Westinghouse to Areva Advanced CE-14 Htp Fuel Project stage: RAI ML1011600782010-04-22022 April 2010 Response to Request for Additional Information - Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Response to RAI ML1015302292010-06-23023 June 2010 Request for Additional Information Proposed Transition from Westinghouse to Areva Nuclear Fuel Project stage: RAI ML1017601942010-07-12012 July 2010 Request for Withholding Information from Public Disclosure Transition to Areva Fuel-Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 Project stage: Withholding Request Acceptance ML1018100672010-07-12012 July 2010 Request for Additional Information Proposed Transition from Westinghouse to Areva Nuclear Fuel Project stage: RAI ML1020705512010-07-23023 July 2010 Response to Request for Additional Information Proposed Transition from Westinghouse to Areva Fuel Project stage: Response to RAI ML1022303402010-08-0909 August 2010 Response to Request for Additional Information - Proposed Transition from Westinghouse to Areva Nuclear Fuel Project stage: Response to RAI ML1030800252010-10-29029 October 2010 Supplement to the License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1032800822010-11-19019 November 2010 Supplement to the License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1100403742010-12-30030 December 2010 Supplement to the License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1100401222010-12-30030 December 2010 Supplemental Information Regarding Generic Letter 2004-02 Project stage: Request ML1017605232011-01-0303 January 2011 Issuance of Environmental Assessment for Use of M5 Cladding Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 Project stage: Approval ML1033700972011-01-0303 January 2011 Environmental Assessment and Finding of No Significant Impact Project stage: Request ML1030701892011-01-13013 January 2011 Docket Nos. 50-317 and 50-318 Exemption Project stage: Other ML1030701132011-01-13013 January 2011 Issuance of Exemption for Use of M5 Cladding Project stage: Approval ML1101806212011-01-14014 January 2011 Supplement to the License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1102000652011-01-18018 January 2011 Supplement to the License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1103202432011-01-28028 January 2011 Supplement to License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1104505372011-02-11011 February 2011 Supplement to License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1104704032011-02-15015 February 2011 Supplement to License Amendment Request: Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Supplement ML1030103832011-02-17017 February 2011 Request for Withholding Information from Public Disclosure Transition to Areva Fuel Project stage: Withholding Request Acceptance ML1103902242011-02-18018 February 2011 License Amendment, Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Other ML1103902632011-02-18018 February 2011 Non-Prop SE - Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 - License Amendment Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel Project stage: Other ML1105301992011-02-23023 February 2011 Correction Letter to License Amendment No. 297 Project stage: Other ML15275A2772015-10-0202 October 2015 Formal Notification of New Fuel Design Project stage: Other ML16131A3832016-05-10010 May 2016 Formal Notification of New Fuel Design Project stage: Other 2010-08-09
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Fehrllary 23. 2010 Mr. George H. Gellrich, Vice President Calvert Cliffs Nuclear Power Plant, LLC Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 SUB"IECT:
ACCEPTANCE REVIEW OF LICENSING ACTION RE: TRANSITION FROM WESTINGHOUSE TO AREVA NUCLEAR FUEL - CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NOS. 1 AND 2 (TAC NOS. ME2831 AND ME2832)
Dear Mr. Gellrich:
By letter dated November 23, 2009, Calvert Cliffs Nuclear Power Plant, LLC (the licensee) submitted a license amendment request for the Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2. The proposed amendment request would modify the licensing basis and Technical Specifications to allow the use of AREVA Advanced CE-14 HTP fuel.
On January 7, 2010, the Nuclear Regulatory Commission (NRC) staff held a conference call with members of your staff to discuss deficiencies identified during the acceptance review of the amendment request. Specifically, the amendment request did not adequately identify and disposition safety evaluation limitations and conditions on the 15 AREVA topical reports being incorporated in the reference list of the Core Operating Limits Report. By letter dated January 11, 2010, you were informed of the above deficiencies. In addition, you were informed that the license amendment request would need to be supplemented by January 27,2010.
By letter dated January 26, 2010, supplemental information was submitted. The NRC staff has reviewed the supplemental information and concludes that it provides technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment.
You will be advised of any further information needed to support the staff's detailed technical review by separate correspondence.
If you have any questions, please contact me at 301-415-1364.
Sincerely, Douglas V. Pickett, Senior Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-317 and 50-318 cc: Distribution via Listserv
RidsNrrDorlLPL1-1 RidsAcrsAcnwMailCenter RidsNrrDssSrxb PClifford, Dss ML100340961 RidsNrrPMCalvertCliffs RidsNrrLASLittle RidsNrrDssSnpb OFFICE LPL1-1\\PM LPL1-1\\LA SRXB\\BC LPL1-1\\BC NAME DPickett SLittie GCranston Nsalcado DATE 02/21/10 02/16/10 0222/10 02/23/10