SoAAF84 THE FOXBORO COMPANY Test Report No. T2-1075 Radiation Test of ElO Series Differential Pressure Transmitter of the Standard Construction Type Conducted @

Isomedix, Inc.

Parsippany, N. J.

Approved by:

.G. McCasland Supervisor, Department 383 Test & Evaluation Laboratory Report by:

hnA. sears Dept. 383, Sr. Test & Evaluation Engineer and Richard Ramsell, Dept. 383 1.i Test Technician, from the Test & Evaluation Laboratory August, 1973 e202O9O338 820204 PDR ADOCK 05000286 P

PDR I

k

INDEX 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Description of Test Units Test Objective........

Summary and Conclusions Comments and Observations...

Summary of Test Results.

Test Procedure Test Certificate from Isomedix, 0

Inc..

Page 1 Page 3 Page 4 Page 5 Page 6 Page 11 Attached

1.0 Description of Test Units The test units were standard construction as follows:

1.1 E13DM - ISAM2 Input Range Limits:

Supply Voltage Limi

.Output Load: 650o MWP.2000 lbf/in 2 S/N 2595238 20-205"H20 Test Range 0-100"H20 ts:.24-60 V dc Test Voltage:

30 V dc Output Current:

4-20 mA dc Amplifier: NO148TE (Prototype) 1.2 E13DM - ISAM2 S/N 2595239 -

Input Range Limits:

20-205"H20 Test Range:

O-l0"H20 Supply Voltage Limits:

24-60 V dc Test Voltage:

30 V dc Output Load:

650o Output Current:

4-20 mA dc MWP 2000 lbf/in 2 Amplifier: NO48TE (Prototype) 1.3 E13DM - ISAM2 S/N 2595240 Input Range Limits:

20-205"H20 Test Range:

0-l00"H20 Supply Voltage Limits:

24-60 V dc Test Voltage:

30 V dc Output Load:

650o Output Current: 4-20 mA dc MWP:

2,000 lbf/in 2 Amplifier:

NO148TE (Prototype)

Remote Mounted 1.4 E13DM - ISAM2 S/N 2595241 Input Range Limits:

20-205"H20 Supply Voltage Limits:

24-60 V dc Output Load:

650o Output Current:

MWP:

2,000 lbf/in 2 Amplifier:

1.5 E13DM - ISAM2 S/N 2595254 Input Range Limits:

20-205"H20 Supply Voltage Limits:

24-60 V dc Output Load:

650o Output Current MWP:

2,000 lbf/in 2 Amplifier:

Test Range: 0-l00"H20 Test Voltage:

30 V dc 4-20 mA dc N0143XS (Present Standard)

Test Range: 0-100"H20 Test Voltage:

30 V dc 4-20 mA dc NO143XS (Present Standard) 1.6 E13DM - ISAM2 S/N 2595255 Input-Range Limits:

20-205"H20 Test Range: 0-l00"H20 Supply Voltage Limits:

24-60 V dc Test Voltage:

30 V dc Output Load:

650o Output Current:

4-20 mA dc MWP:

2,000 lbf/in 2 Amplifier:

NO143XS (Present Standard)

Remote Mounted 1.7 E13DM - HSAM2 S/N 2630073 Input Range Limits:

20-205"H20 Test Range:

0-l00"H20 Supply Voltage Limits:

63-100 V dc Test Voltage:

75 V dc Output Load:

600Q Output Current:

10-50 mA dc MWP:

2,000 lbf/in 2 Amplifier:

N0143SY (Standard)

-l -

1.8 E13DM - HSAM2 S/N 2630093 Input Range Limits:

20-205"H20 Supply Voltage Limits: 63-100 V dc Output Load:

60O Output Current:

MWP:

2,000 lbf/in 2 Amplifier:

Test Range: O-1O0"H20 Test Voltage:

75 V dc 10-50 mA dc N0143SY (Standard)

2.0 Test Objective To determine the ability of ElO Series Transmitters Standard Con struction both 4-20 and 10-50 mA output types to function during and after gama irradiation to a total dosage of 1 X lO7 rads.

3.0 Summary and Conclusions All transmitters functioned without failure to the total dosage of 1 x 107 rads.

The 4-20 mA output transmitters with the present standard amplifier (NO143XS) exhibited output shifts of less than 0.5%. Output shifts of the 4-20 mA output transmitters with prototype amplifier (NO148TE) and the 10-50 mA output units (standard amplifier N0143SY) were largely negative-going. Errors as high as -4.2% were noted.

Units with remote amplifiers had output shifts, zero shifts and span changes of less than 0.3%.

Zero shifts on units with integral amplifiers were comparable to out put shifts. Span changes were less than 1.5% up to the total dosage.

Performance tests performed in-house before and after irradiation showed little to no changes and were within published specifications.

Step response tests performed before and during irradiation indicated no effect due to irradiation.

4.0 Comments and Observations 4.1 All test data taken by the Foxboro personnel was initialed and dated by Mr. William McKimm or Mr. George Dietz of Isomedix, Inc.

4.2 Irradiation of the transmitters was interrupted at various times for removal of other items in the "hot cell". The periods of interrupt ion were recorded and time adjustments made for the scheduled dosage level checks.

4.3 The effect on the transmitter output of removing and replacing the radiation source was 0.1% or less at any time.

4.4 At a dosage level of 9.25 x 106 rads the dose rate was increased to 2 x 105 rads/hr to shorten test time. Results indicated no effect on transmitters by this action.

4.5 Visual examination of the transmitters found only a brownish dis coloration of the amplifier circuit board Conap conformal coating.

5.0 Summary of Test Results (Units will be designated by last two digits of serial number.)

5.1 Calibration Characteristics 5.1.1 Before Irradiation S/N 38 39 40*

41 Zero Error, %

<0.10

+0.10

<0.10

<0.10 Span Error, %

+0.20

+0.33

+0.15

-0.13 Maximum Error, %

+0.38

+0.60

+0.43

+0.23 Avg. Hysteresis, %

<0.10

<0.10

<0.10

<0.10 Repeatability, %

<0.10

<0.10

<0.10

<0.10 Linearity (Ind), %

+/-0.13

+/-0.15

+/-0.13

+/-0.12 S/N 54 55*

73**

93**

Zero Error, %

+0.10

+0.15

<0.10

<0.10 Span Error, %

<0.10

+0.20

<0.10

<0.10 Maximum Error, %

+0.38

+0.35

-0.10

<0.10 Avg. Hysteresis, %

<0.10

<0.10

<0.10

<0.10 Repeatability, %

<0.10

<0.10

<0.10

<0.10 Linearity (Ind), %

+/-0.15

<0.10

<0.10

<0.10

  • Amplifier Remote Mounted
    • 10-50 mA dc Units 5.1.2 After Irradiation at total dosage of 1 x 107 S/N 38 39 40*

41 Zero Error, %

-2.80

-4.52

+0.10

+0.18 Span Error, %

+1.05

+1.83

+0.20

+0.10 Maximum Error, %

-2.80

-4.52

+0.48

+0.45 Avg. Hysteresis, %

<0.10

<0.10

<0.10

<0.10 Repeatability, %

-0.15 0.13

<0.10

<0.10 Linearity (Ind), %

+/-0.15

+/-0.30

+/-0.10

+/-0.15 S/N 54 55 73**

93**

Zero Error, %

-0.85

+0.25

-2.38

-4.00 Span Error, %

+0.45

+0.40

-0.13

-0.18 Maximum Error, %

-0.85

+0.68

-2.72

-4.30 Avg. Hysteresis, %

<0.10

<0.10

<0.10

<0.10 Repeatability, %

<0.10

<0.10

<0.10

<0.10 Linearity (Ind), %

+/-0.20

+/-0.10

+/-0.20

+/-0.20

  • Amplifier Remote Mounted
    • 10-50 mA Output Units

5.2 Irradiation Effects Dose Rate 105 rads/hr.

5.2.1 Output Shifts @ 80% - During Dosage, rads S/N 38 Irradiation Outp ut Shift, %

39 40*

1 x 105 2 x 105 5 x 105 1 x 106 2 x 106 5 x 106 1 x 107 See Graph No.'s 0.10

-0.15

-0.83

-2.00 See Note 1 1

-0.20

-0.70

-2.75

-3.85

-3.60

-3.05

-3.20 2

0.10 0.10 0.10

+0.18

+0.13

+0.1 3

+0.1 3 3

+0.13

+0.18

+0.23

+0.23 See Note 1 4

Per the test schedule units were removed from irradiation.

  • Amplifier remote mounted (outside radiation field).

Dosage, rads 1 xlO5 2 x 105 5 x 105 1 x 106 2 x 106 5 x 106 1 x 1O7 See Graph Nos.

54

<0.10

<0.10

<0.10

<0.10

<0.10

-0.28

-0.33 5

55*

<0.10

+0.13

+0.15

<0.10

+0.20

+0.18

+0.25 6

Output Shift, %

73**

-0.48

-0.88

-1.73

-2.10

-2.30

-2.40

-2.60 7

93**

-1.80

-2.73

-3.70

-4.10

-4.20

-4.20

-4.08 8

  • Amplifier Remote Mounted (outside radiation field)
    • 10-50 mA output Units 41 NOTE 1:

5.2.2 Zero Shifts Dosage, radq S/N 1 x 105 2 x 105 5 x 105 1 xl 06 2 x 106 5 x 106 1 x107 See Graph Nos.

Dosage, rads S/N 1 xlO5 2 x 105 5 x 105 1 x 106 2 x 106 5 x 106 I xlO0 See Graph Nos.

During Irradiation 38

<0.10

-0.25

-1.05

-2.80 Note 1 15 54

-0.10

-0.23

-0.30

-0.38

-0.48

-0.70

-0.95 11 Zero 39

-0.28

-1.28

-3.63

-5.10

-4.75

-4.13

-4.65 15 Shift, %

40*

<0.10

<0. 10

<0.10

<0.10

+0. 10

+0.10

+0. 10 9

Zero Shift, %

55*

73**

<0.10

+0.10

+0. 10

+0.13

+0.15

+0.15

+0.15 11

-0.30

-0.73

-1.38

-1.80

-1.90

-2.05

-2.37 13

  • Amplifier Remote Mounted
    • 10-50 mA Output Units (outside of radiation field)

NOTE 1:

Per the test schedule units were removed from irradiation.

41

+0.13

+0.15

+0.18

+0.18 Note 1 9

9 3**

-1.50

-2.65

-3.48

-3.98

-4.18

-4.20

-4.00 13

5.2.3. Span Changes -

During Irradiation Span Changes, %

Dosage, rads S/N 38 39 40*

41 1 x 105

+0.10

+0.12

<0.10

-0.13 2 x 105

+0.30

+0.42

<O.10

-0.13 5 x IO

+0.38

+0.70

<0.10

-0.13 1 x 106

+0.85

+1.32

<0.10

+0.23 2 x 106 Note 1

+1.27

<0.10 Note 1 5 x 1O6

+1.12

<0.10 1 x 107

+1.47

<0.10 See Graph Nos.

16 16 10 10 Span Change, %

Dosage, rads S/N 54 55*

73**

93**

1 x 105

<0.10

+0.10

-0.20

-0.25 2 x 105

<0.10

<0.10

-0.28

-0.15 5 x 105

+0.10

+0.13

-0.38

<0.10 1 x 106

+0.10

+0.15

-0.30

+0.23 2 x 106

+0.28

+0.13

-0.35

+0.30 5 x I06

+0.28

<0.10

-0.28

+0.28 1 x 1O

+0.45

+0.20

-0.13

+0.18 See Graph Nos.

12 12 14 14

  • Amplifier Remote Mounted (outside or radiation field)
    • 10-50 mA Output Units NOTE 1:

Removed from irradiation per test schedule.

5.3 Step Response Tests 5.3.1 Before Irradiation 80% Step Response S/N 38 Time, Sec Up Down Deadtime 50%

90%

<0.04

<0.50 0.90

<0.04

<0.60 1.10 Response S/N 54 Time, Sec Up Down Deadti me 50%

90%

<0.04

<0.60 1.00

<0.04

<0.60 1.10 39 Up Down

<0.04

<0.55 1.10

<0.04.

<0.60 1.10 55**

Up Down

<0.04

<0.60 1.00

<0.04

<0.60 1.10 40**

Up Down

<0.04

<0.55 1.00'.

<0.04

<0.60 1.10 73*

Up Down

<0.08 0.92 1.56

<0.08 0.76 1.44 41 Up Down

<0.04

<0.60 1.00

<0.04

<0.60 1.00 93*

Up Down

<0.08 0.84 1.36

<0.08 0.76 1.56

  • 10-50 mA dc units
    • Amplifier Remote Mounted (outside of radiation field) 5.3.2 After Irradiation

@ 1 x 107 rads unl Response S/N 38**

Time, Sec Up Down 80% Step ess otherwise stated 39 Up Down 40***

Up Down 41 **

Up Down Deadtime 50%

90%

Response

Time, Sec Deadtime 50%

90%

<0.04 0.52 0.92

<0.04 0.60 1.00

<0.06 0.60 1.12 54 Up Down

<0.08 0.68 1.08

<0.08 0.64 1.10

<0.06 0.64 1.08 55***

Up Down-

<0.08 0.68 1.08

<0.08 0.68 1.12

<0.08 0.60 1.04

<0.08 0.64 1.10 73*

Up Down

<0.08 1.08 1.80

<0.08 0.72 1.32

<0.04 0.64 1.00

<0.04 0.60 1.00 93*

Up Down

<0.08 1.08 1.80

<0.08 0.72 1.28

  • 10-50 mA dc units
    • Test point was at 1 x 106 because units were removed per test schedule.
      • Amplifier Remote Mounted (outside of radiation field) 440-

6.0 Test Procedure 6.1 Installation All eight test transmitters were mounted in a horizontal position through their normal mounting bracket to a vertical pipe stand.

The units were placed in a "V' pattern so they would be uniformily exposed to the radiation field. Placement of the specific trans mitters is in Diagram No. 1.

6.2 Monitoring All units were powered continuously and a 80% input signal was con tinuously applied except during calibration runs.

Outputs were recorded on a 4-channel recorder with a timing and switching circuit changing the four unit record every six hours.

Output current readings were read across precision resistors with a DVM at specific intervals.

See Figure No. 1 for schematic.

6.3 Irradiation Test With the units installed in the "hot cell" (cobalt - 60 source) and operating, initial calibration runs and a step response test (0 to 80%) were performed. The initial dose rate was 1 x 105 rads/hr up to a total dosage of 9.25 x 106 rads; at this point the rate was in creased to 2 x l05 rads/hr until the maximum total dosage of 1 x 107 rads.

At various dosage levels tests were performed to check transmitter performance. See Test Schedule #5 for specific test points and dosage levels.

6.4 Documentation All data runs taken were verified by personnel of Isomedix, Inc.

6.5 Test Equipment The following is a list of equipment supplied by The Foxboro Company and operated by their personnel.

6.5 Test Equipment (Con't)

A. Input Equipment

1. Power Supplies
a. 2-Hewlett Packard Model 60155C -

30 V dc (4-20 mA units)

S/N's 01418, 01594

b. 2-Electronic Measurements M212A -

75 V dc (10-50 mA units)

S/N's 6096, 9433

c. 1-Princeton Applied Research* Model TC-l00.2, S/N 157 (24 V dc for switching circuit)
2. Input Signal
a. Mansfield & Green Air Deadweight Tester*

Model 650WC-SS S/N 66614 Accuracy: 0.025% of Input Pressure

b. Step Response Equipment
1. Capacity Tank - 1732 cu. in.
2. Air Loading Regulator - Moore Products Model 40-7 Pressure Range 0-200"H20
3. Solenoid Valve - ASCO Model 8320A25 3-Way Valve
4.

Pressure Transducer - Statham Gold Cell with Interchangeable Diaphragms 5 lbf/in2 diaphragm

5. Pressure Gauge - Wallace & Tiernan*

Model FA-145 S/N PP11538 Pressure Range 0-120"H20 Accuracy:

0.1% of full scale.

B. Output Equipment

1. Resistors
a. Load Resistors* - 400P +/-20 ( 4-20 mA Units)

- 500o +/-2o (10-50 mA Units)

b.

Readout Resistors - l00Q +/-0.02o (10-50 mA Units)

- 250o +/-0.02o ( 4-20 mA Units)

2. Digital Voltmeter* - Data Technology Corp.

Model 350 Accuracy:

+/-1 digit on V dc ranges S/N 18611

  • Asterisk denotes equipment checked by the Foxboro Company Measurement Standards Laboratory and referenced to the National Bureau of Standards.

6.5 Test Equipment (Con't)

B. Output Equipment (Con't)

3. Output Monitor - Hewlett Packard 4-Channel Recorder Model 7414A S/N 1145A
4.

Output Recorder Switching -

Potter Brumfield 8 Pole Relay - 24 V dc

5. Output Voltage Readout Si"Itching -

15 Pole Multiswitch - Foxboro Co. - Pt. No. V1OIBW Tool Number A-171 from Dept. 383 FIGURE NO. V To readout resistors (250 or 1000)

Switching Circuit 1,2,3,4 -

Denergized 5,6,7,8 Energized Data technology DVM Input "H20 "H20 to transmitter M+G Dwt Tester 45#

Supply HP Model 7414A 4-Channel Recorder

d OX 10 TO THE INcH 40 0703 Iii Ae NIB*ASI

.P.KUFFL

& ROSERII CO.W 4-k

+*

qd L

_~l L10

Top View Transmi tters Front View Source Height 5 S Diagram No. 1 Placement of Transmitters

I4 SE II AHTHMIC 46-0012 KI~ rp 1.L 4 E 39ERS CaO.

IEMl ARITHMIC 46'6012 4

YCL I! IA 7() l)IVIION MAO IN U.S.A.

  • C CIKIUFFEL & ESER CO.

cm as Co so r ri i4

~

t n T

ITWI It

- I I

II

,H

.jI

...b i

.~ ~ j!jJ j

it 111 IM l't hi-.t rN

-It

-Uttlli, 11 1

HT:l I

iI l I

,I o w C I

I I I i

I I

  • I I I [ I I "1l.l1 i i i i i k t

l lf llIU Iil

!lllllll I~~~~~~~~~ lII illlilll!!l L

Ai t A I?HMIC 46 6012 m!! '

40 rlr,)Ip Aga

SEMI-I 1 rARITH MIC 46.6012

-1 C

  • 71)IVISIONS3 5AI Sn

3AITHMIC 46 6012 f

KiUP'CC).

i.

nUKN Co

I I IHMIC 46'6012 IK~E

~

I HV1,A AAA mw 04 C AD O

i"

-1 1

1T~

~

f~

1TF;]TK Tf Jfl

! i A.

.f 4

1 I

I

-l M...

It,

-t I

iitlt i If Jil f i l l

. 1i 1it

! 1i wt 4! IV i

I l~4;

]it I

Ii t J.~

I-i I Ii Ilk A:

T I TIf L

I

_,i L

41i IT I

F1 11I I~

L H IHI4 4

I il lit+/-~

f

~

_-I I

14tM<f

&ir Ti-nu~

I' 1-1.0

-3.0

I

-110 11

&j!A HMIC 466012 K CU F F K LI.

R 0O r

rr i.

r r1*r Ip 0 0

-L tj i I~ 11 4-11iH jtIitiiI i"T~~j illt FF1 t iIM 1 IIIM

' I -f I

Iti-

-4.0

4J '

,MI,.*A,,,,,,M,-

40 0012 I.

.i A

l

/tiivi;i,

{

iI,

  • J fE{

r t

r~qrn,,.

I I j~I I

- I -

I -

I -,

Il1 1

'. ;,I I

SEI;ARITHMIC 46 6012 ii KrUFVVL 1%

r'EflC r I,'~ I, F I

1I 2.4, itL

!l Ht I

~

I I

h4LtI f

+

'O!

1 A 1Vrj 64

SEMI

.ARITHMIC 46 6012 11 Cy X 7?n fIV~olON5 "An ii U '

KEUFFEI. A ESSER CO.

fill PH 1:F-II Allll it j

~

-u

- V~V I:

4!1 Fi t

i I~

I I

li't' Ai~~~i~~t ti1 0

TA iiI

i.

ii~

Hit liLi IF t*

I:

I ~~W 1

~H n

tiI r~~'

~

t 1 7__

i i l I.....

--AD ji~

111 11.L W IIII'~'

H 4i414hr IL Liii LL J.KTi

46 6012 iq U I.

'FFrL. N fr.53r.lf C a

r r

r F

m till till

1. 1 ! 1 ! till L!

It; ilw !:

LL L

T JJ

'It !::I.;i! ;.:E,

4f J11I 4 1 I -F T

Ilk j

tiIT w m..

d fill 1; if 7T if 11 iJI J.

lit FFF t J-1 r 41+11111-1 L1 Ltit 1: it HI I! if I

H 11JIii if 77 it tw it FF TIE Lo iij if T [

it it J

EF ii : ji :

it!

7 i

p fill j 1 1 t1 I

L-!-

JA 1:1 I

H I I t

11 :

I t I L Tr tilk

-1 L -i-J t

I! io; I I; I UI-1.11 Li, MIMI I

Limit it ut H -Tj till il

-1 !T-I 4ill hli 11 i i I if !it it LLI, Tr Ill i :.$

T t

!M.

'i:, 4.;. : - :i l T 1; T I.

I it:

17 of 7-p 4

41

rMg I jj(AR4II 1jiMtIC 46 6012 iti I

IJ.11 ki hil Oil

  • I I l ' 'i ~ i t L Li n

I liii~

i ilkii, I

l 11 911 h

s cNel'ij jj A 1qI V 46 6012 fri U.

I i2i

' if IT I-47421;1 ~Ci.1111 4

7 LS 50 4:30 I-

I" RRDAl 7 1 RJ1 N

II Iu'~rn I I'l MARE T R,

.1 in IT!

(.a ~---I-y-,-,- I ri-~

I rry r..

t ~

r -

~jI 2

a,

~-.~

~z 0 I I I I 10.,

+41 1 !1

-- I I

-i 7

1 3I l.*.

I

-)

I;

-i:

-7r Ii i

I......

I h....t-"

N::l I

'1 Ii '.

ill X-I0-R d !ul # !T

I"rli I

+

I(

. 77bLl

'2E: 108a~

e

'd atr V.A

.1. F7HI 4

1...i" I

'I (ni

.1:1

.6 U,

6*I I

I I

III 75:

htl

-r

.1

1.

I;

..... 1.1 I.

I,

1 I

__ +/-

_ 1.4.1-

-~

i-!-~-L-.

i--I--,

~ It!

I 1

T

]t1J 1~1imIPT VV7t77~

VVi~VVYYV I

I unrl I

m I I

J N I JIm r

'IIZ ',,I o

~ ~

L I

N I

I I

1 !4 1" X:

46 60121 i

'I,~

SE)TrGRTHMI C 46 6012 4 CV l l mit.;IONS DI 1. U.S A.

01 r

,I I

I I

I I

I If II i T

I~~III T

I I~j I'll J4-I 4~

1;i TIt ii,,

II~~~~.i

-J-*

I I

l 1

J I[IIIIII I

i:

IMI rI IT T-1ThTh ii I.I IJ~

T 1 I

rI U I ; III.. II.

I

, I IJ I I I !

I

.4..

J 1 L II 4-0 0

h.

L4