ML100040220

From kanterella
Jump to navigation Jump to search

Request for Additional Information Response to Generic Letter 2008-01, Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems
ML100040220
Person / Time
Site: Grand Gulf 
(NPF-029)
Issue date: 01/06/2010
From: Lyon C
Plant Licensing Branch IV
To:
Entergy Operations
Lyon C Fred, NRR/DORL/LPL4, 301-415-2296
References
GL-08-001, TAC MD7831
Download: ML100040220 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 6, 2010 Vice President, Operations Entergy Operations, Inc.

Grand Gulf Nuclear Station P.O. Box 756 Port Gibson, MS 39150

SUBJECT:

GRAND GULF NUCLEAR STATION, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION RE: RESPONSE TO GENERIC LETTER 2008-01, "MANAGING GAS ACCUMULATION IN EMERGENCY CORE COOLING, DECAY HEAT REMOVAL, AND CONTAINMENT SPRAY SYSTEMS" (TAC NO. MD7831)

Dear Sir or Madam:

By "GNRO-2008/00066, Nine-Month Response to NRC Generic Letter 2008-01, Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and [[system" contains a listed "[" character as part of the property label and has therefore been classified as invalid. Systems|letter dated October 13, 2008]], as supplemented by "GNRO-2008/00068, Nine-Month Supplemental Response to NRC Generic Letter 2008-01. Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and [[system" contains a listed "[" character as part of the property label and has therefore been classified as invalid. Systems|letter dated November 20, 2008]], Entergy Operations, Inc. (Entergy, the licensee), provided a 9-month response for Grand Gulf Nuclear Station, Unit 1, to U.S. Nuclear Regulatory Commission (NRC) Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems."

The NRC staff has reviewed the information provided by Entergy and determined that additional information is required in order to conclude that the licensee has acceptably demonstrated "that the SUbject systems are in compliance with the current licensing and design bases and applicable regulatory requirements, and that suitable design, operational, and testing control measures are in place for maintaining this compliance," as stated in Generic Letter 2008-01.

The enclosed questions were provided to Mr. M. Larson of your staff on January 4,2010.

Please provide a response to the questions by February 22, 2010.

The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for NRC staff review and contribute toward the NRC's goal of

- 2 efficient and effective use of NRC staff resources. If circumstances result in the need to revise the requested response date, please contact me at 301-415-2296 or via e-mail at fred.lyon@nrc.gov.

Sincerely, Carl. F. Lyon, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-416

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv

REQUEST FOR ADDITIONAL INFORMATION RESPONSE TO GENERIC LEDER 2008-01 GRAND GULF NUCLEAR STATION, UNIT 1 DOCKET NO. 50-416 The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided by Entergy Operations, Inc. (the licensee), for Grand Gulf Nuclear Station, Unit 1 (GGNS) in its "GNRO-2008/00066, Nine-Month Response to NRC Generic Letter 2008-01, Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and [[system" contains a listed "[" character as part of the property label and has therefore been classified as invalid. Systems|letter dated October 13, 2008]], as supplemented by "GNRO-2008/00068, Nine-Month Supplemental Response to NRC Generic Letter 2008-01. Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and [[system" contains a listed "[" character as part of the property label and has therefore been classified as invalid. Systems|letter dated November 20, 2008]], and determined that additional information is necessary to conclude that the licensee has acceptably demonstrated "that the subject systems are in compliance with the current licensing and design bases and applicable regulatory requirements, and that suitable design, operational, and testing control measures are in place for maintaining this compliance," as stated in NRC Generic Letter (GL) 2008-01.

Guidance on NRC staff expectations is provided by Reference 1, which is generally consistent with the Nuclear Energy Institute (I\\IEI) guidance provided to industry in Reference 2, as clarified in later NEI communications. The NRC staff recommends that the licensee consult Reference 1 when responding to the following questions:

1.

On page 8 of Attachment 1 of Reference 3, the licensee stated, "Surveillance test procedures for HPCS [high pressure core spray], LPCS [low pressure core spray], and RHR [residual heat removal] systems need to include specific acceptance criteria and actions to be taken if voids are detected, thereby making them consistent with the LPCI

[low pressure coolant injection]/RHR monthly functional test procedure. Required actions will initiate the means for quantifying and trending the amount of gas present and a process for determining possible sources of gas accumulation."

The NRC staff requests that the licensee expand on the statements made above by providing the following additional information:

a)

Describe the specific acceptance criteria that need to be included for the subject systems.

b)

Describe the means used for quantifying and trending the amount of gas present in the subject systems.

c)

Discuss how amounts of gas found in the subject systems are used to adjust the surveillance intervals for the systems, when it is warranted.

REFERENCES:

1.

Ruland, William H., U.S. Nuclear Regulatory Commission, letter to James H. Riley, Nuclear Energy Institute, "Preliminary Assessment of Responses to Generic Letter 2008-01, 'Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Enclosure

- 2 Removal, and Containment Spray Systems,' and Future NRC Staff Review Plans,"

May 28, 2009 (ADAMS Accession No. ML091390637).

2.

Riley, James H" Nuclear Energy Institute, letter to Administrative Points of Contact, "Generic Letter (GL) 2008-01, 'Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Contain Spray Systems' Evaluation and 3 Month Response Template," Enclosure 2, "Generic Letter 2008-01 Response Guidance," March 20,2008.

3.

Letter from Krupa, Michael A. (Entergy) to NRC, "Nine-Month Response to NRC Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems," October 13, 2008.

- 2 efficient and effective use of NRC staff resources. If circumstances result in the need to revise the requested response date, please contact me at 301-415-2296 or via e-mail at fred.lyon@nrc.gov.

Sincerely, IRAJ Carl. F. Lyon, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-416

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC RidsNrrLA,IBurkhardt Resource RidsNrrDssSrxb Resource LPLIV r/f RidsNrrPMGrandGulf Resource MRazzaque, NRRIDSS/SRXB RidsAcrsAcnw_MailCTR Resource RidsOgcRp Resource RidsNrrDorlLpl4 Resource RidsRgn4MailCenter Resource ADAMS Accession No' ML100040220

  • memo dated OFFICE NRRlLPL4/PM NRRlLPL4/LA DSS/SRXB/BC NRRlLPL4/BC NRRlLPL4/PM NAME FLyon

,IBurkhardt GCranston*

MMarkley FLyon DATE 1/6/10 1/5/2010 12122/09 1/6/10 1/6/10 OFFICIAL AGENCY RECORD