W3F1-2009-0061, Response to NRC Request for Additional Information Re Request for Relief from ASME Section XI Volumetric Exam Requirements - Second 10-Year Inservice Inspection Interval

From kanterella
(Redirected from ML093160319)
Jump to navigation Jump to search

Response to NRC Request for Additional Information Re Request for Relief from ASME Section XI Volumetric Exam Requirements - Second 10-Year Inservice Inspection Interval
ML093160319
Person / Time
Site: Waterford 
Issue date: 11/06/2009
From: Murillo R
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
W3F1-2009-0061
Download: ML093160319 (91)


Text

S-Entergy Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 Tel 504-739-6715 Fax 504-739-6698 rmurill@entergy.com Robert J. Murillo Licensing Manager Waterford 3 W3F1-2009-0061 November 6, 2009 U.S. Nuclear Regulatory, Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Response to NRC Request for Additional Information Re: Waterford 3 Steam Electric Station, Unit 3 - Requests for Relief from ASME Section XI Volumetric Examination Requirements - Second 10-Year Inservice Inspection Interval Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38

REFERENCES:

1 Entergy letter dated June 1, 2009 "Requests for Relief from ASME Section Xl Volumetric Examination Requirements - Second 10-Year Interval" (W3F1-2009-0026) (ADAMS Accession No. ML091540088) 2 NRC letter dated July 23, 2009 "Waterford 3 Steam Electric Station, Unit 3 - Requests for Relief from ASME Section Xl Volumetric Examination Requirements - Second 10-Year Inservice Inspection Interval (TAC Nos. ME1426, ME1427, ME1428, ME1429, ME1430, ME1431, ME1432, and ME1433) (ILN09-0069)

Dear Sir or Madam:

On July 23, 2009, Entergy received communication (Reference 2) from members of the NRC Staff requesting additional information associated with Entergy's relief requests from ASME Section XI Volumetric Examination Requirements - Second 10-Year Inservice Inspection Interval" (Reference 1). contains Entergy's response to the NRC request.

There are no new commitments contained in this letter.

04-7g

W3Fl-2009-0061 Page 2 If you have any questions or require additional information, please contact me at 504-739-6715.

Sincerely, RJM/RJP

Attachment:

1.

Entergy's response to the NRC information request

W3Fl-2009-0061 Page 3 cc:

Mr. Elmo E. Collins, Jr.

Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 NRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam Mail Stop O-07D1 Washington, DC 20555-0001 Wise, Carter, Child & Caraway ATTN: J. Smith P.O. Box 651 Jackson, MS 39205 Louisiana Department of Environmental Quality Office of Environmental Compliance Surveillance Division P. 0. Box 4312 Baton Rouge, LA 70821-4312 American Nuclear Insurers Attn: Library 95 Glastonbury Blvd.

Suite 300 Glastonbury, CT 06033-4443 To W3F1-2009-0061 Response to NRC Request for Additional Information Re:

Waterford 3 Steam Electric Station, Unit 3 Requests for Relief from ASME Section XI Volumetric Examination Requirements - Second 10-Year Inservice Inspection Interval to W3F1-2009-0061 Page 1 of 87 Response to Request for Additional Information The requested information was as follows:

As requested below, please provide detailed and specific information to support the bases for limited examination in all requests for relief and, therefore, demonstrate impracticality:

a) Include descriptions (written and/or sketches, as necessary) of the interferences to applied nondestructive examination (NDE) techniques.

b) As applicable, describe NDE equipment (ultrasonic scanning apparatus), details of the listed obstructions (size, shape, proximity to the weld, etc.) to demonstrate accessibility limitations, and discuss whether alternative methods or advanced technologies could be employed to maximize ASME Code coverage.

c) Fully clarify the wave modality and insonification angles used for all ultrasonic examinations.

d) Show cross-sectional coverage plots to describe ASME Code volumes.

e) If surface examination is required by the ASME Code in addition to the volumetric examination, state whether surface examinations were performed on any of the subject components and state examination coverage that was obtained.

f)

If not included, state whether any indications were discovered as a result of Code-required examinations, and how these indications have been dispositioned.

The following pages, in the aggregate, provide the information requested above.

UMITED B-A EXAMINATIONS W3 Responses to NRC Requst tor Addilionel lrormatidn (RA ITCM COMW.

ITEM NO.

No.

DESCWRIPTON "COVERAGE db

  • f BlAO OZ4t01 REV Heads tLarn eorage E.

oimitd by shroals, bous o

and Flange

.ong.atior S-ned swth Mana UT eswn. Pre-Appeodis VII E.. Angles:

S-eam 02401 MT

- NR.

UT-NRI Flange Utares and ees, where accessible. Si, ibh wide ling ilgs e-ey 305 ar'uod tle cirornetereca ofthbe wad. Shroud locafea " romuethe tea ot 1hw weldon ttw head side.

Flange localed 5 aches Seen the ens on the opposnte side.

See anaohmeln 02401 0" L. 4". 60eS, 0AS 100% of ltb ASME Cnda Required Volta

.cannot be.chis-d dm to the ehror.d s..ppodt iIrertette lo UT scening Se attatshnt 02-001 There were s eltewrfti. NDE ethdsr adoen.ed lebhslogies tht wnid he pnactioaly eWployed to msirtize NME Cede oeoeage.

a11 2 024-2 RPV Head Peel e-e-t heedpoeweld to pel wed orso.

heio.wId 02401to thecager of l ranl UT eeao. Pe-Appedi VlI Ear Ailes:

Se taeW 02402 s s e

inatison RI Segerd to Peel ree.or heed. T

.e reacoor head tdru.d covrs 31% of rhe weld end nea*s UT e.a-oo pottorsod teis irtervaL Fegerd weld at imited s the

.Iest 4" of thl 22.1 toial ncahee of weld hecetre tethnorisr. cannotecoess so-heweldares.

0" L,

'S,.0"S, 1t%

ECnid 4" of the 22.1" total.weld oated F the5eo rbSek n Flnge bol oles 1 & 2. 100% ot tfhe/ SME Code Raquoied Vobate ca-t he eorird while tlb hreud in in place.

See attRuoento 02-a02.

Nu allernalios NOC methods or ed-aaed recthlonies co-,d be practicefy "Iemployed I Varxirjýe ASME Code cveage.

_o-e-m tion Co.rage Profile shewing the Code Required Voba.t (CRV), Obstrctiooe eo See aaehel 02402.

.he eaUTaa.,yea, Um.aglee ved.

Eamidatisn Cowrage Protile showing the Code Reqoined Volr (CRV),

Obeetrwfids to the uonm area. UTaeanrangls ved.

Wa1andTaeane Pre-AppodillV I-An4gles:e2 B122 02403 RPV Read Peel Reacrt head poel weld In poal weld runs bor the dor weld lo-al le the oarder ot the 100% ot the ASME Code Required Volame carerf he eanmined while fthe I" L h"-S, Es, No surlaoeaedim o NW Negroand toPael reactor head/Flee reacto head shromd t

oor.s 1% of the weld. UT Vlaridti islketited ehioud iioplce.

p rf d tids iruel.

Segird weld a Is the lwese4a of lbs 22.1 total inches of weld bec-a-e -eaoh.booao oceawe access the s° wald area.

18%

E.andid4" of the 22.1" tole weild cadathe Fo ga90 n rkbeen Flage boll Woles 1& 2. No al0artiv NDE methods or adwmaed techlogiee oodd be pracicaty eployed o -naimiaNASME Code corege wdbord roulog the shiorau.

See attacthew 02-003 See etlchent 024053 Page 2 of 87

UMITED B-" EAMWNATIONS W3 Respones to NRC Request for AdditioalIrfow tion (,Re ITEd COW.

ICM NO.

No.

CESCRIPTION S COVERAGE d

N Eoawt Angles:

No outfaoe eosomination eRJ BW.130. 1-011 42 Hot Log Nook Siogle side eonation (to, mjority of weld olr),

do to weld Ioatron adjoert to thte Ifat UT e-0' L 4,Sý,.05, See Attarl 0rtored his iceroat.

to SG h

1 noole treolioi. Scanoig perforrd with 0'. 5"s. erd 50's where eooesribh (irwt4dlng wo dueotio loraooessibleporioo we.. ld -o-e.

100%

of te ASME Code Required Vol~ eoa-t ueeneumntd with high angle tra-itio fhr pipe to nozzoe.

See Mtaotwwnt 03410 Se actertert 01410 86.60%

No altartio NDE methods or advanmed tehoologias ocld be practicafly mployed to emir the traolion area.

B3.130 034011 30" Cold leg to 66%

E owooragetimihedby-r I-to eadweldgeo trryoonrigwaticr, dofohranstiorotths 1aroatUTe-m E..mAtj1es:

UT-NRU 1412 SG#1 nozzlol djaoent to the weld toe. Soaood with 0', 40's ard 0

0.s, where a.oessih..

0' 1-45'S. GO'S.

No surfaoeo ainatioo irrforwdts intervW t

100% of the ASME Code RequiredVoume

n. t e.e.d.wd with traoition Ste o

Ne03411 Uro shelm to -Iote.

No a&errtfie NDE ethod orad.,d ed teohrlogie odd be praofially Se aatchent 03t11 erwoyte d to exmin the traosion area.

.ee afttachendt 03-11 W1.110 009 1401 Pressuwiter Swe 645 L

oo rageh imited by hzo to headMonfigfationm dm to tranitonc theezt lW-1tUTeo Em Awngles;:

oTN No.te to Heatd djaeMd to the weld to. Soawd with 0'%

4S*s aod 6

0'r, where a.oescibt..

0' 1. 45'S','S.

See Mar

. 05401 Weld 1005 of theIM OW Code Required Volare ca-not he hieced with Ith nowl to head onfigo.rahto Se atten4r9et 01.00.

No afer-ti NDE So thrt or adomed teohwlogies,olkd ha proritally etrployed to e matir the rraoion areaI

.064tahmrt S09.

Oeawirration Coo.rap PoofiLe shewiog the Cede equgired Votr (CRV), aWd thetmrer,

d

.oarea that pe.rde Tdn the UTaearncoerage.

83.110 00410 Prenowioer Spray 74.80%

E..

.aoage limited by woe to head conoigmatio. da to transitio oW the noe

-11 UT ea Loam Angts:

e410 Sosrfac nhsid t

T-R Noote to Head adjaerd to theweld tn. Scaened with 0', 45' and 60's, where aa.es.ib.

0* L. 4'S. 60's, Weld 100% of the ASW Code Requirodo Vao ca-re aocWewd with e nozle to head confgoratior See Hchacowrrt 01410.

No ahteratie NDE metheds or adoawed technlogies.oodd be practially employed to eaie the tramsftiu uea.

S.. aftachfe 05-410.

Exmintion Corage Profile showing the Code Required Votume (CRV), rod the Iransitin area that prevents Go1n the UT eam corrge.

W3.110 05-011 Preesrioer Saely 65.90%

E eanootragetimited de toozzlerohead oontigwatwrcduetch ansdinofthenot ns l UT mm E.. Ang,"s:

Setl n 05411 ut.

Rt Nodle to Head adjacent to the weld toe. Ear also Inted dw to head to shell t ranion area This 0- L, 45"S, I'S, Weld bh-th d he 4,aiatsanor 1..

and the 13" aWiateo6 fol f, 20.

0% of the AS Code Required Vohameoar

-I aahi.eod with the

-hoe to held oonhfegmerio No aheRatie NDE horthod or ad-ed techonoIgies ould be preotitafy Se Araert 00411 erployed to e.-

the traicion area.

Seeanaomeno 05-'d.

Exrnmteon

.cerage Profile shawing the Code Required Voture (CRV), end the tr anihon alea tht prevens 1o.s the UT eam corage.

Page 3 of 87

UMTIED B-4 EXAMINArINS W Reao-es to NRC Cagist tot Additional Innnation (RAJ)

ITEM COMP.

ITEM COVERAGE b

d I

NO.

No.

DESCRIPEEN S COVERAGE a

h d

B3.11R '5012 Pressurizer hate R65.10-A tw aoorager litad dm.to a to head.on.gratioro ditotransitionoltt a

of tha azzh Manual UT-C Anigles:

e.dttctant051No1 N

r-trtmerm this idaroL UT-NRI Norate to Head adjap.to th.t eaid toI. Ear abo limitad di to head to shea traoition area. This 0 ',

415. 05, Wed abhntited tha4 aaial a.an Toa 13" and thal SW aial.an tor 20".

11).% of Iatt tME CodeRouuird Voh eoanna t bea hie.d with the

-1a.l to tead oonfigoratio.

No alterfatina NDE methodts or adanoed technlogjes coold he prafticatgy S

nt.tnt at-Ri.

eoployd to eandi the tranitjan area.

See atatahmnt OR-012.

EC tbn Courage Pro ia showing th Coda Required VaOna (CRV). and tha transilton aea. that praenta Imits tha UT earm o-a1ag.

B3.11R 05l13 Presorizar Naftat 65.90%

E-t ourageo itaitd dd to -zal to hadilofigratiou, do to taoition ot th

-W Mzle UT E-a Argle.:

ua.to o tt 11 Noortaa.amthis iroat VT-NRS Nozlie to dead adjacet to Itha weld toe. Examalho lidlted di to haa d to trftasitio

-area.

Th*s

" L. 45,to 60" S Weld barrted Idthen4a"aial aor 13" anld the I.aialsn 2Vorao.

laOS oAthtAdME Code RequtedhVohean

.anot b, achieed withthih -ae to head ooohgora5ior1 No aUmatie NDE melhods or adonied aiechnoogies ootld ba practicaly eiptoyed to einrnnoa the t ranionara.

Sea atlactoent 05-013.

Eaaminatioo Coerage Protie chowing the Coda Raqtdrd Volume (CERV),

and tha traraiteoi area that praerta linaic the UT ear oorare.

W.120 05414 Pssoriza Surge 29.40%

hcanirng imied by mn hi.to head taranition conigoetioa haning pertornrdwitha

.0" Mana0.Mnual UT oExa Angles:

Atteoao0a14 Nocuteaoathiciote L dT-R Nozle Inrr aint Ts, whersacoassible.

R0eS TO S wad Eadi' angeniafly in CW aWn CCW 100M at the ROME Code Raquired Votran oan. t ha achieed with the aotua to head configtatiotu No aUermiu NDE mehods or adwa"ed tehnoologies coold be praticraly motyd to exaroin the tranadin area.

Sea.aH.tano*t 05a-14.

E*amiation Co-rage Protile showing the Code Required Vutrna (CRV), and the t-aidmroarea that prIn...s lirns the OUTeamoo rage.

W.120 5-O1S Pres-i-r Spray aa.40%

toatiag inritad by rztlo to head tramitian contigtation. Scating pertformad with 0,s Manoal UT er Ear Angles:

ee tttanton-a Na snrace..

m tti iaaal. VT-NO]

Nooole In-r Tnd

.os, whereaccessible.

V0 S. TV S ied Radius tanrtpintiay in CW snd CCW.

100% of the AS]ME Code Raquired Vuoan canmt bha chieud with the matte to head rontigtation.

Sea aoacsnert 05-A15.

No.a11 ti-NDE S

athoda or aduaned teahologiec touLd he pra.ticafly emptwyed to emnin thetran aio area.

See atauchanat05-t15.

Eatoination Conrage Prole showing the Code Required V.Ir

CREV, and the trarotion area that prevents 1irds the UT ear coerage.

W.2 a-0A16 Prrsizr SNaey 7ta tantng lSi-tMed by -wzke to head tranition oontiguatiuo.

scanning pertOnoed with Oe Eanoal UT a-E.am Angles:

ee Ottaowtt 0R.tE o rtae rthainat VT-O 1L-l7 No'aa hour and toas, where acessaibla.

ea.

tOr S med Radis tangeitiay in CW ando CW a1s-at t00t of theASME Code Requited olumae cannot e achid hd with Ile nwul to heiad ntigmatino.

No aetrativa NDE methdod or advamed technologies co-,d he pIacricaity anp;uyii to xaa-i.t the trastioon ara.

Sea atetarnant 05-016.

Emination Cosraga Protile showing the Code Raquired VolI (CRV), and the tranihtan area that preetc lanos the UT eam moerage tar welds 0541..

0o-t17, 05a18.

Page 4 of 87

-I

UMITED B-F EXAMINATIONS M3 Response to NRC egtq-t tot Addiional ltorotion (RI)

ITEM COMP.

ITEM N

d NO.

No.

DESCRIPTION % COVERAGE b

p T

WM.40 26406 PMR Nozzle to 0o 635 Scanning limited an r dedcer edoe to OD taper mn, the weld to. 4-a, 5ROzL

,r 600RL Manol UT eon 0ole. Used no rottce eco perotrted UT -N.

5S Redocing Sate ted Ior scanning, where accessible. NOTE: Per MRP-it39 tpection.26-006 had a,4 45" RL St" ML this hdaRvl.

and Weld ltrctmimal weld oedlay inttaled in RFO-16i.

tIM of the ASME Code Required Volt cannot he nheed with the *ozw e to redwing sate eMd OD conligteltrn.

No aUrrie NODE me-tods oradaed terhnologies coLd be practicanly Seea e2i.0.

eroldOed to exinine fte tr-ioion area.

Esornination Coerage Protile chewing the Code Required Volt (CRV), end tie Varradeto area that preents linits lhe UT e-ao Iooerage.

2604 01 Prpesswirer atety 70%

1San conreo Untied on the redoeing rote end saidel de to OR coneigwatics 4",

R awtUT enigles Used See atactent 26-t01.

n rface eNo ame d

UT -NeI Nozzle In 11 G" and 6D'RL od Ior seaaing whete a.cessibie. NOTE: Per MRP-139 Ihspeltior, 25-a1 hed 4O" RL. S0 EL tlea ideroe1.

Redmrig Sate end a rut strMctat we o-leay installed Or RFO-15.

100% of the ASME Code Requited Volk-e caow he W.hevd with h nozzhl WeHd to h.od.onfiguration.

No atfer*io NDE nethds or adoandtechnologis cod be practicafly SeasHaclehnent 2-1.

employed to ecmr the tranodion eree.

See arattenawe 2-a01.

ECnination Coverage Profile aheowing the Code Required Volts (CRV), and the Iraositnin ar4 tchat preontr limte tihe UT eUaronto rage.

Page 5 of 87

UMITED B-4 EXAMINATlON WS Reopooee to NRC Reqest tot Additioabloooatio IRAI)

ITEM COw.

ITEM b

c d

I NO.

No.

DESCRIPTION z*OER" b "

59.11 064006 14h Stdoon 86.10%

Sc.nnig inimted o -oz.

l de of weld d to z tetdaitioa" MaOd-S. 40. "

.. and MonutleUTao AlesUsed seattdterel-0tG.

No sofaocas e

pertfoed UT-NRt Cooldg Noole to GO-RL sed m

to saoning, whre aooessible. NOTE: Pet MRP-139 topectfio. ZG6-01 had a 45 & GO-S; 4 RL, "' RL.

this interuL Sate end Weld tOn strutoal oeld overlay intafled i 6O-16.

So RL 100% oI thw ýSME Code Requirod Voto oanot be l euiood oithe tozzle to s*

end oontisuretiorc get tactwt06066D.

No eltora*tw NDE methods or advaoed lchoologies -oord be practioanfy mployed to eoami this orea.

See Wt-lehrror 06-006.

Eomiation Coerage Profil showing the Code Requited Voltme (CRV) and no*letreasilon.

B9.11 07T13 RCS 30" Etlbowto 82.20%

SonnJM od-troled lo 17.8% ot weld cidcfereoeduetoe dj.oe-lperoraorsuppor Manool UT.ea AngWn Used hees 01t.

No ssoesawmpett otrd UT - NRI r0t Elbow Weld strutu.

45,s and 60,s -ed fot soanonog, whetea.-essist.

tis ileruaL 100% otMhe SME Code Required Vloaoe csnol be auhied widhthe "L. 45W 5

S & O S penoet support sttotwe in plso.

No alteratiu NDE mehods ot ada., ed teohoolgogies scud be practically Se attachmeon 074013.

eployed to e im this.t.a.

See a.ao1.n0t 074013.

E amiat ion Coverge Proie showing tIre Code Reqoited Voloae (CRV). sd the tranition areo that ptevets I"nds the UT u5m,owrage 55.11 08.014 30 Pipet, Saet 71%

-an co-rage limited on aseend sidM e of weld d tto shortsfe tend legth andl te ManuaUToea Pre-Appondiyilfl Angles Used atteawnt 114.

No1eeam pettored UT-NR end meld edjacont prop cunotiguratiorL.

4otRL and 4otRL used tot sceorig, whore applioable.

this interul.

100%'o. the ASME Code Reoired Vokame anoot be achieved - the pipe to SORL. 4RL

-afe end anndsat e to pop elds as lha design pots those 2 welds witdn o

7" span. O mismath of 1h casl puop noole. o cast sate end to rolled pipe wrth 2 logsearo reduoes.co-rage.

No altertJ iv NDE mhods or oduo.ed deohologies totSM be practiceay See egatson.a.14 employed to eair this area.

See eodotshno 66414.

E-Cmhation Covrago Profile showing the Code Reqoired Vooe (CRV), and 1ho OD oonourpreunting -0% UT exam.o. rege 9.tt o52 OhNozzleE.

87%

ucarhingImded dow siae orweld dso eowOODonh atiol. niingrhoar us MaSOal Tea Angles Used Seeaactewl -02.

MT-NU UT-NR Pieoe to 30" Elbow or elbow sidke coverege. 45"S sod C°S wad tot sceoing. whowe tccessible.

Ed. Pt-oe meld 100% of the ASME Code Reqoired Voatome o.-ot be achenod doe to 1ho OD 4D.O,N ootigrghiono of the 30"elbow to elthowleoron were and lthe sho elbow No alternatie NDE mehols or odv..eld i

od practicdy See eleenl 04t2 mployed to eoxirw this ares.

See atooe2ne.d 05.ae, Eamintern Covrage Profle showing the Code Required Vole (CRV), sod the G0 contou prevetoing 106% UT e.m covrage st.11 09oOs

  • o Elbow to30" 6%

ca ming ited onelbow side of weldo 17'" o6ciro-1mere doe to adja.ent.

m psr nt Monul UT e-m Aleo Ued OS tfe'dwMn

s.

MT-N T-NM Elbow Weld support. Scaning perormed across weld om pip. side. bt o seond directin id obtrucled area doe to tO cladodig, whtoh precludes bouning -ebd. 4WtS used tsr 100% of rhe ASME Code Required Voln amort be achievd de to e Sha aosachlenr 09406 scanning, where aessible.

poenool rspport pe WiMi access to 17".1 the weld.

No alderntio NDE methods or edwaned technlogies corld be praoticafly employed to eain this ares.

See atetachent.9-65.

ECrmnnat'io Cosv,ag Profie showing the Code Required Voba (CRV) and the OD conolo prevnling 100% UT e...

coverage.

Page 6 of 87

UMITED BR1 EXAWNATMI I%

WI Raspooses to NRC Reest tot Adddhdnl ldfnntion CRAJ)

Inmm cowP.

ITMm OEKG NO.

No.

DESCRIPTION % COVERAGE It C

U l

.. 11 09.-I6 30- Eiho to Sate 2.S0%.c-ting uited ons. ent. dide o.1.. d d tothewidth and shape of sates st. 4Sa esl tat UToa Anegt woles osed:

4"S. o

.a ent 09416.

No surtacn ea-perotd hT-NI Md Weld (RCP 1 60N. anet45%

.O" and 70R RL med tot soannitn, where a..e.sh.ble.

6RL, "RL.O7RL this ittetoaL Inet) 100%

otthe ASlE CodeRequiredVoueoanwoteshifendotheeowwto Seaeatnte9416, oats etot OR tnioweth ot the cast oate end to tocdedtwaetded soes ow ith 0 kang sees aduces Coortage.

No ettetnti NDE tethodo t edened techoologies.ou.d be prateitely etmptoyed to exnain this atet.

See ettaotottant 00.010.

ECmitation Coortge Pofitd shooing Ihe Code Raqtred votn JCRV), and the ocontow pteenting 100% UT et co.etag, B9.11 09-17 30 iafe ent to 17.1.%

Scanning ited onat s ndoideof wed de to the widthand shae of sateend.M o Saiing W1 ItUT eAngtles

-od: ttL 4 RL o

0916.

P NW.

UT-N fCP tBRWed onWPopside is loo dered -eot "do e

srtdto ce htoin-esteel t

atetiaL 19% ot sae end oide was atso obhttuted by at. dia"Wtet nzde. US RL med for s-anning, whets 100% of the ASME Code Reqoited Votte canna he abhieed on the ofte end See atftctoent O9s7.

aceosible.

dtowIidthond MhMpe ot the safe ende nde I,

e in esm

-e

  • UT o ast otailNessn mtael, a "best Wort" examn No attertatI. NDE wthodo ot adv.-ed technologies otuld be ptactioaly employed toI e in thisostea.

Se. atteattent 0-017.

Esawm titon CoWtaga Profile showo the Code Reqoited Votune (CRV) tor both 0s-1tI and 59017 we-do, and the OD contot pteefning 100% UT s~m 1.1l 10-t01 tCP IS to M at..

l.

I.%

castinin ted onate endsideo weld dJ to the widthads eot sate end. SNanning ManIa UT-e Angles o

ed: O RL41111 heetahewtdlo.O1.

PT-NWU.

UT-N 2dweld n Nozzle Wide nied by -le ttition.

4!1 RLm ed tosanoing. wheIe acssibld.

100%

ofIteASME CodiefRequiredholaneoannolIeeChieadwonthestsend M

eeattahentt-001.

Urn to width sod shape ot the oats eod. Nnag o t e oide was tinted d-to the tanoition.

No afttet*ai. NDE wethwds or od.-aned telholtogies nould be ptdctiealy enodope d to exastne this ates.

Esmwination Coorage Profite shows the Code Requited Votane (CRV) for weld 113-t01 rs! tI: limikt aio-.

.11 10402 SaleendM to 30' 44.2%

.carSongn Ie nd On seenoide d to wdth and shape ot sate end.Pieoiscarsaing I.aw l UT ea-Angles ond: 40RL,

eeatactnttts.

PT-NW.

CT-NW Pipe Weld (RCP IS Ieriteed h b

adent wo-le hit 0.,

ot 116 ot nirotenerete..41 and Sr RL med tor

"'0RL,61RL 4T"S otet) scaning, where acc-ssiblh.

10t% of the AMME Code Requited Voltae Cannt be ecWhe.d on the sate sod Ur to widlh and shape ot the safe nod. Scanning on the pipe ide was linited d-1 to -ote (weld 1-00) in scnt ea.

No elternliw NDE mettwds ot add ed tehtwlogiee could be pratinafy See anectuntlp02.

  • pltoysd to.awmin this erea.

See 0tta cotnntl10h2.

Ewmint ion Co-ragt Profile shows the Code Reqoited Votune (CRV) tot weld 10-002.

19,11 13-001

G h 3tT Nozzle to 6z.50%

harsting liniled to Notale Exteion side orgy, due to NRtate OD nonfigoratir"dn LIT.at oTe*n temsed: O"L 04hS, 60"S Setationtnt 1"01.

hit-Rt UT-No.ota ECtenion Additionaly, Roads Cidenio side eoanarg was toted Ur o edjanent weld no. 13002.

weld resuting in approoimtely only 50% orage ot the rqtetdot eI-f the Nntze Eitdenon side. in the aoial scan direction. Cucmnterentiatl owage was twbsfmtuted. 4r 100% of the ANME Cods Requirted Votne cenot be *aewd as scanoing i, See atantn113-01.

aod IIh S -ed tor scanog, where- -oeoble.

lantedtothenw etesdtnwsideottheweld. Theproxiity owelt 2to 13,01 xdtaes

.i.a ocanning to 50%.

No alterntio NDE owthodis or ed-ed technologies could be pratcicaly eOpoynd to e-atnine this area.

Se i cl~t13-001.

Eaminattion Coerage Ptote shows the Code Requited V.Io.n (CRV) t. weld 13001 and ptoouwla It weld 13202.

Page 7 of 87

UMJED S-J EMAMINATIONS W Remposse to NRC Reqoes tar Atditiooe Intootio (tRAtJ ITEM COP.

ITEM NO.

No.

DESCRIPT1ON % COVERAGE a

2 0

w.Il 17t433 1to Pipe to 57%

Eoariast IoIoted o rtedoe side -

t tpet onftigrat ttteion OX f toed 1-;W-1toTe-Ant gles s0oRL 70"RL Seettotor 174te pettatttwd oT-NRt Reducer Weo Nc.otlg petrf d with 4Ws acod 70"Rl. where coessible.

LhR otetaL tOO%

of the ASME Code Requited Votute oewwt he chieved doe to Use tspt Sc. attaoteent 174-33.

(o-pcratet swzcoes).. the tedrat side.

No ctterttiu NCE mtotwds or cdwmsod teohtotogies -owd be prattiocy eopltoed to emmmit this ctec.

See attaohment 17-o0.

Ee*roh*ttioo Cooercg Ptofile.ow.s the Code Reqidred Vobotte (CRV) end the taper fhet folts the UTse n.

01.11 tI Jt0, 12" Pipo to Votln tOS hoanning timltod to 7ipe ride, ondy. doe to valve Oh caotngatioa. a5rt and tO'RL usod to, tanuci VT exam I ytole ned: 45S, SOVRL. toNtroot tV0adtd o sutoroce exatr pertortrd aT - NRt tr*0t Wrtd r;e aninrT. otlootort a

htssle this lotrersoL 100% It Ihe ASIdE Cod-Vaqlaled Vot-aa-o,- be acnhievd dae tase 00 Soa ottaotntnt t1-Ott.

cnntIiaitioo p _aoos ocunoi.g.

No alt1, naio SEE mothodo 0r advanord ttohnotoJies could he ptacltiatty employed to iertj is area.

See ttaeh el 1S406.

E ramidtion Caorugeq Prate rhao, Mhe Code Ioqoiid Vohlea ICRV) and the cotorthtIis the UTea.

Bt.11 210G 14 Pipe to Val 50%

Oiesidedneoan too due to valve.onfig*a.,

45.70s, nd 7'RL.ed torwocai.

MaTiexam Re UTm A

ed: 45S60-S Seestta n2-...

PT.NF.

UT-NW Weld wheteaccessible.

70, 70iRL 1004 ot the RtME Code Requited Voteme ocotnt he,Need d. to ingle 21atota.ent 21-056.

side aooess typial io.1 pipe to I1-oofigmatros.

No aoertnaive NDE oethods or adoated teohotogies o*,dd be practi-cay emIpoyed to etatr this aet,.

See actetahent 2t-066.

Eat*oiton Coerege Ptode chows the Code Reqaire VotIme (CRV) eod sigle side -ccess limitchor.

68,11 22-02 Efow to 14" Pipe 88%

10" ot d trewside of theweld..e.r theintredos of theelbm,

,ws eoacessi.ible dm Mnuai UT ege's Used: "'S, 60 Seecttc-teient 22023.

cPT-N.

T-NFU Weld to psetratio hole. 4 Eho f-S hsed for sesnning, whereeooessible.

100tA of the DAME Code Requited Votlme canoot he aohiead do to the See ttchtoient 22,1123.

peeltratiso preetds soanaing tIof the weld on the ethow itdosoo.

No alterative NDE tshods o cd-aced teohologies,old he prcoticflly emttpoyaed to esuaio this a.ea.

See attaotment 22-23.

E.ntlatn Cooctoge Ptotde shows the Code Reqired Votonw (CR0).

B.It1 2N-a4.

4Pipeto C4ox 75%

Edcaing Itmited to 50% cirtoeteoe onree side dr to brts h

-onetion rdi.4-ModUTgles eUsed:

456, WS, hae cotet25409.

PT-NU.

UT-N 25.015 3 Tee Weld 7Oeo used hoi so-aing. where coessible.

70' 100% o the MIME Code Requite Vobeat t

oa the, deed due to he braoh -oation radits (n-p r.l.

ski o nest o

-a11 diaieter pipe.

Seeotloo 215409.

No aU.,.tiw NDE nt hods-otdasted tchwlgies coldd be pacoticaly emploIed to ecaniý this ctea.

See.actachtol 25006..

ea tio Cooetge Ptotie shows the Code Reqisted Vot.n (CRV) too w1,ls25-009 cnd 25-015 moligqawtimo.

'I to Page 8 of 87

LIMITED B-J ECAMIiCATIMN MW Respones to NRC Reest lor Mdrliorel rtonnatim (RAJI ITEM COMP.

ITEM NO.

No.

DESCRIPTION % COVERAGE b

d I

R.ll OS-06 4"Pip. to V.al 50%

ingle sded urnmination du Is e,]w cooligrariomr. -70"sed Nr sc.w0lrrq, where MaAuaoTs egles Uwd: 45rS. 6M,,

Seeslrent51.

PT - NRL UT-N 25.015 end Weld accessiblde.

Tn*

100%

ol tIe CMME Code Raquied Voin e cro be etied due In sinle side access tppios in Ea pipe to naw csnfigralions.

Sea 2fapno 6.015.

No alteroa te NDE hoeldo or du

.ed

-echoologies bCd be prolicafly employed to ecenie this ares.

See ellsld eneld 05-016.

EsLoination Cosregs Prolde sho-s Ine Code Required Volane (CRV) Mnd single side access nlmtationw r

to,25.S sd 250111.

01.11 2 Pip, toElbow 76%

Soenuog lmred to 50% chrc-aeleea onlbeelbo sidsduelolterroradosredis ManoallUTes CoglssUsed: 4I"NN eea r-C JTNa dT-,.

054R20 weld T0s ued or scanning, where accassible.

7MN 1.0% of the AME Code Required olV.1-oano be1achee d d-io elbown irdod radius typioal in rmot s-n0a diameter pipe to litting cor.tiuroliorm.

No aer-liua NDE nallods or ade ld technologies cod be pracilily mplyed lo e.zarn Iris ares.

Se 111attanent 25.019. Examninton Coosrge Profile s-ows Ile Code Required Volm (CRV) rasd fle pipe to elboC pofls or welds as-l.

s19od o25 RO.t 204622 Teato4"Branor 62%

Nanirglimiedlo1'.onreeside du.rolhre radiuolheI.45-Tsosedorsonn a

lU.Tem rge4s5Sed: 5N60S, Sea1laant PT-N.

CT-N Conpectior Weld bere accessible.

70TS 100% of the dOME Code Required Vobne cannot be achieved due IC I. srhor.

reli-of the crotoh 1o the Tee. Typical oe all.-

l dinarer Teas,braob corroioms end elbows.

No altern1i. NDE merhd or adoed

.es.nologies coudd be practioaBy Rrtployed Is sxwmr thIis area.

See alttachmeant ZS2*zZ.

Esaminalion Cooraga Profile shows the Code Required Vol.

(CRV) and leb pipe to elbw profile.

89.11 2u-e02, e S Reducing 50%

Scanning horied on boh bsdde o weldd slo l

.bo o reducerOCoonfiguari o-"s rranalUT e0 C le's Uad:

UT -

Angle.cn45-.,

Salt.0Z.

uT-RI SieN.nd el r

-eed for canning, where accessible.

70*S Elbow Weld 100% of the A.rOC Code Required Vobn caneot be cte.ied due to tleb nIr-p.raBel surfaces on te redoirog sa.e rod side of lIe weld.

No alaera ri. NDE methods or advaned technologies cod be pr..licsaBy See flant 26.D2.

mpluyed to mamim this ares.

e dacmn 26-002.

Esawination Coerago Po ile sho-.s Ir Code Required Volo rr RV).Vasd tIe redming sale sed to elbow profile or oWlds 26-E02 ard 260 07.

5.11 264007 e

educing 52%

Scanring biled on boh slide of welddue to elbowr to rducerCn lrJiguarion.

4-70"s Mar UTaeam

-gles Usd: 45-S.S, eeats ffl240.

Nrt m iirL CT-N SaWe.red

_o wed tor saning, wCere accessible.

tWS Elbow Weld 100% o1 lb CMME Code Required VOlIer cannot be

,achied due to the non-perskit surbaces on Ihe reducing sate snd sid, of the weld.

No aerna ltea NDE rltbods or ad**aed techoologies node be practicaly see r

60L e

yploped to e nine thIis ares.

lvoaWnr 26-402.

Esamslsun Cosrage Po1"e sho-s lhe Code Required 1o4w JCRV) and lIe reducing sale end o elbow profile for welds 26002 reld 26D-RT.

B9021 Is06 2" Drai. No le to 050%

-owirntioniIsdonsateredslde o I

welddo a adjacent -sfe.e to pipe. eld.45, U

M UTe glesiad:45RL6,6GRL, PT -NWI.

UT-NFU Safe end Weld 60LRL al TCL used tor scnng, wheresccessible. NO.: Per MRP -139 lrepacrior.

45., 5"S Ihis weld haS a ful strmtural worley itsabed in RFO-15.

160% of Ii AS ME Code Required Vobame oset be achied on Ire r-sle Is Sea sfe end weld due to the prrorly o. t sale end I. pipe weld.

No atrernarive NDE wetlods or ado ed tecbrlogies co-d be praclieIay employed lo esnur Ibis alea.

See atlachennt16s406.

Examiatron Cucerage Protile show-the Code Required Vobkna (CRV) and Ito proirdpty of the adjaoen-weld.

Page 9 of 87

UIMTrED B-J EXAMINATIONS WM Respones to NRC Requst for Additional hetonnafllRAn ITEM COMP.

ITEM NO.

No.

DESCRIPTION % COVERAGE 2

h d

05.21 27402.

2" PiptoEbow 7E, 6

hareringl initedloSo%oiu ers ontheelbuw sldeduetotheirtradostdi

.6t. ManoalUTet ngles Usedd:

45"S. 60GS. Seathalerent2l PTONRI.

UT-NRI 27.004. Weld 70"S and 7"RL med to suanoing, whels a.ceo.ible.

70 S. 70"RL 27.0.6, 10111%

of the AdME Code Required VColoe contol he toed trotorhe ehlboow S atst 27402.

27-0o7, side ot the weld doe to the s'Ta idrados radim of 2" elbows.

27.009.27-020 No alteto-ti NDE othods or adu ed teohoolugies -o6id be praoliuafy eployed to

-ine this area.

See attauH. ent 274002.

Ectmination Cowrage Protile srows the Code Required Volaet (CRV) and the 2" pipe to elbW intrados profiles wluch limit eam couerage and typical on this oontfiatiaon For welds 27002. 27404,21.005 27406, 272407,.,

21-Ot,.

08.27 ut-O10. a"Pipeto Elbow 700 SoatwinqIo~tdedrloltO uitntteefowe~eonlthesibow sidesdoeslthe intradostradiue. 4R,60. MranuaUT ecaqo Onle's Uqod: 40"G.CG0", Oee atatahwoetdtl-Ot.

lT TO 27-Ot1, Weld lo'S crt70"RL used fn suawir, whets a.cessible.

ICS, 72RL 27-031 100% or the ASME Cods Required Vo.1ne uaoor

-haeau d frto the elbow Gea 27alt.

side or the weld due to the s-l1 inrdados radius of 2" elbows.

No altertatis NDE mthods or ad-awed technologies -ooAd be proticafly employed to exanvio this area.

S - a"t.h~r T.2O10.

oeatiahon Coerage Profie shows the Code Required Vocume JCRV) and the V pipe to elbow irdos end e., tados profiles typical 0 this conigdteion foh welds 27-o), 27-ott,27-031.

08.21 27-037 Tee o 2Pip-ne 62%

SGcannitN ed to 1.Zon te side d-to the rdi-of the te. 45-70-s and 70"RL. ed fo MaaulTeam UTles Used: 4550,

hea dhoehl27437.

T-NW.

UT -0N Weld soettg, whore atoessible, 10h.

7O RL 100% of the ROME Code Required Voluhe cannot ha achieved from the Toe side of the weld do to the smell inds radius of 2" Tees.

One anauohenfn 27.027.

No alteHt-ih NDE methods or ad-a.ed teohnoloies -oold be praotiuafly empioyed to etio rhoe area.

Gee ac dhoent 27-437.

Euenorttbn Comoaga Profile shows the Code Required VPoeo (CRV) and the 2" Ten to pipe we..d onad-peofte typial o this cortfigqatiort E281 27-054, Zo Pipe to Elhow 7%

cannig iqmied to 50% cir tere he ontelbow sde due o the intrados,adim. 45-Manat UT esam dAle's Used: 415OS,

eOeS, aS e

l PTaeoan-o hostr24tionP UT - NRI 27-ORE Weld os used hoi sua.ning, Wheae accessible, T0oS NWU.

100% o the ASME Code Required Vo.1-

--nt beacuedh from the elbow side or the weld due to the sell intrados radius o 2" elbows.

No aielt*rtiws NDE methods or advared technologies cuIld be pra.ticaty e opluyed to ei this area.

Gee a"acheronl 27-a4.

Eani*atwion Coetaoe Protile shows the Code Required Volme (CRV) Tal the 2" pipe to albow irdoades and afttados profiles typical on this -on-igwatin for welds27-004 and 27-anS.

0.21 Z-1,ot. 2-Pipe to Elbow 75%

Schntiir mnited to 50% cirwhteree on the elbow side due to the itra.dos redi-. 45-M-a 01 U

m ocoqles Used: 45OS, Stilt.

Seatffchnerd 28401.

PT -OW.

UT-NW 2-0202. Weld

70. used hit scaonin., whotre ec.essible.
720S,28-000, 28sC.77, 100% or the ASME Code Required Vohmoe ca-ohf he aulaeN d now the elbow side or the weld due to the snoG itrados radius of 2" elbows.

No afteretai NDE methods on adr ed teWhtwooqes could he pretinafly eo*piayed to exanine this area.

See hlehtohe*r 28"001.

Esamiation Covrage Profile shoow the Code Required Volhoe 2CRV and the 2" pipe toelbow itrdos and head-profiles typical.. this onfiguhtio. for welds 28-e01, 26502, 28001.21-102, 20-R77,28-278.

I-Page 10 of 87

UMP3ED B-J EXAMINATIONS WM Resposes to NRC Reqest for Asditiool rfo tjoo (RAJ I*TM COMP.

ITEM NO.

No.

DESCRIPTION % COVERAGE b

d f

B9.21 22-012 2-pipe to 2" 2' 70%

tronnmg hooted to I0% circwoteree oo tee side dU to branh cooctioo rediu.

arwlt UTe eqagql's Usd: "US'. G"S, to 28.12.

PT-NRI.

UT-NRI rn Te W

Oooirg muted to 90% 00 pipe aide Ur to an edja-No cdmp. 45-T red tFo.c.ooog, 70"S wtrere atoessibrle.

10R%

of the ASME Code Required Vottene carot b-acthie-od tro the brrnch oor otlo side ot thwe wdd df e toftt e sraU t

rado redir etthe broorh cooreion of 2" Tees.

Se tahet281-12.

No 1tferefir NDE methods or edvaeod techoologies roo. be precticaly rployed to eoaoire thio ares.

Seeatcmn 281-12.

Eom tion Coerege Profilt shows the Code Required Votmer (CRV) and the pipe camp tirita tior The 2" pipe to braoh co iohto weld irados profile is typioao on thir ontwigatio.

O 21 28 4

2".2".Tee-to 76%

hocan uniitedtofRoirorerrerere on te5 side d to brnh -ot meotior diw.-.

-m tTem Ungl.'s Used: 4S', 60 S..

281.

PTNRI.

U-N 2U-4,d 2" Pipe Weld oosued lor omoarNrg wtereeooessibe.

70"S 100%

of the AOME Code Required Vohlee oanrmt be ahieved lm the Tee ide&oft, -weld due to the-sm 1 Wiltredo-rdir typpAl o.borroh oo iomtio of 2" Ts.t.

S" tacmn 28-413.

No alterntiv NRE melthods orIedvaed teorhlogies oordd be practioafly eploped 1o eoamirw this eree.

Se.~c~n 211413.

EorInrtion Coerege Prote shewe the Code Required Voorme (CRV) aid

oooigeation for welds 2 U-0.3, 2074, Z-O7S.

68.21 U8-416 2 2

' OTnto 51%

tcarrin limited to. 1% o teeside d-to therodi-of thet.

Scooing limied to 0% orr arlUT eWo rleUsoUsed:

4%S, "Sr, 1 ttiil-l2l1f.

rT-NRL oT-N 2" Broach rorch ooreclion side Ur to or adjaenel oamp. 43-irs wed for soanning, whetr t0ro

.oonection Weld eooeesihle.

100% of the ASME Code Required Wro rme c.rt be achievd from the Tee side of the welUd d

to the smH intredos tadirs typical or breah coonotiio of 2" T....

No Idterrti. NE mEthods or ad.ed teohooloqi"s -ould be preoticfy employed to coaroir this lere See ettachoert 28-030.

Esuamioon Cor-e9, Profile shows the Code Required Volroe (CRV) ood the 2' Tee to pipe weld iitrados profibe typicl o this.oooigraoioo.

69.21 284076 Tee to 2" Pipe 62%

o in limited o1 12% o Meside

d. to theirodi. of the t.

G, 70,S.usedfor MaIr, l UTexar I ngle's Used: 40'S, S.30 fSee z..7..

PT-N.

UT-NRI Weld

ceinohrg, whoere ecessible.
0.

S 120%

of the ASME Code Required Volure o w

e achieved fom the Tee Ide o

Iheweld doe the W irados radk, s typpa oo brarsoh -oo loo of 2" Tees.

on ftiaol-rnt 28-0TH.

No Ulterrrti NOC methodo or

.dned teohologies ouLdd be pra..ticely erployed to e..-Ie his aree.

tree aotacreNt 28.076.

CE*oi*otion Coorege Profile shgos the Code Required Vobwre (CRV) aod the irrdes profile Ippcly.00 this oofiguretioo, 5.03 11-108 12" Safety neetioi.

60%

S airglimed to= 3" pipeside.

to noDle configatirn ID Lad prem tos-to ia l UT eA'"

"gle UseUd:

4S 1

ttii

.09..

T -NRI UT-N Noold e to 30" Pipe "irtlo coverge, voi the bor.

-o.

wed for sceaio n

. whe..

aooessible.

Weld 100% of the ASME Code Reqoired Vtolme ocwt he

-t chie vd o nzzle side of weld uing,v pathudn to the cieddig.

No lterrtmivo NDE mthoda or odo ed teohnologies ooudd be practically te UfeI-ro 08408.

emploped to es.min this area.

Se t cmn 0840B8.

Eaomination Coerage Profile showing the Code Required Vo.1 (CRV3, anW a

profie of the downstream side of the e0 m Page 11 of 87

LIMITED C-A EXAMINATIONS W3 Reopones to NRC Requst for Addifioel hnralow ion (RMI) 1FEM COMP.

ITEM NO.

No.

DESCRIPTON

% COVERAGE 0a c

d Cr1A0 04026 SO Inermdadae N

t.

.,ooobsfrItin bo4-ed y"wide -dinsupporfr rwqg loafed 23fro'- to*ofweofld, Raol UT e-jgles U-1ed:

45S, S"

SeIa, nt 04426.

TT-NRI T-NRJ ShellroConal 0aroond ci ferene.45 and Ems used for,oanlig, where eooessihle.

S-el1 Weld 100% of the ASME Code Required Vo.Ine -not be e*hi*ed from the lower side of tfe weld d1e to tIhe ouafiow support ring located 2.3" frt the weld

e attoarreot 04.026.

No e11eretiue NDE wlSods or edenoed teohnooogies oo.dd Ire preotiloy erpfoyed to xamnino Iis area.

See elchmerrrt 04020.

ECrnination Coerage Profile shows a sketch of tIre ideatrion sppod riog and tI proexiriy to t

-weld.

C1.20 04-429 S 00 Top Head 9%

c anonig limited for 11.3%

of weldoirurfere, d-.o 14 in lalioo lug. 1-ted 3.S' Man-lUT exm Ugl-'s UW d: 4 t'S, aO'S lao nlt02e.

No UT-N Tot.s to Top Head Irw we-centerllie uvery 36t -mrd the oircwferene..45 Vand 00s aed forIscnig, Dome Weld w00er%

enessible.

lee 1

of tho ASME Code Required Vole canot be aohieud do to l1re pewee welded imreetion bo9s in the s-anirng amr.

Se eaomrýent 04-029.

No eaternnalie NDE trods or edna-d technloies c.ld bhe pr a.tiocBy mployed to emmim this aree.

See ateotr.-rr 04029.

E~rrinat ion Co.ereg Prolile ohows a skeoth of the insr.dliOo srppod toys nodatm e proximity to teweld.

CI.z0 54074 S"r" Dow-Htet 1147 1

iourelon or op am bottonm -

nzesaddleweld and thehorzold sohe weld imdfit ti-Manol UT es'i lesUsed: 45" S, 70e5 S aolhwNN lac.ea.-

UT-NM Exchanger Shea to Flange Weld 100% s IhenN ASME Coe Requireds Vsk

-enotbe aoNeddetothe dm attahmentg 54074.

!short flange enk and the init and ordler norle reinfor-eWred pads welded at a' cd 110 on the shot No 11e-naie NDE mthods or ado ed

-eohoologies lon ho praotiocly mployed to eoein this area.

See etacl-,enI 04074.

EuminatCl srege PrNfile has pit ro of tho vssel end a sketah showing the s-anmng linitat dm.

C1.20 154074 Stodon Heat 50%

Co waion o top andh botom noýueaddleweld aM d the horiondale heaweldlknr es

,M noal a

Mnleos Ud: 45UT "eeatr0e S, 70TR57.

Nos T-NRI Exchanger shol to eoam Flange Weld 100% of thet. A E Code Required Volmre cannot be ahiened due to the Se attaohonan 04.075.

shod flange wk on thube shee flange and rho inlet aed oWlet noole r einforcemnt pads welded at 0" cod 1e0" to tho shelL No alternnalie NDE thods or edoanoed technologies covld be praotically employed to eromine this ares.

See aHatarcrent 50407.

tnirrion Csrge Profle has pit wee of the SWt DOown Heal Erofrdnger a.ssel and skeoth showuig the soeroirjdatfio.

Th Page 12 of 87

LIMNED C-B EXAMINATIONS.

WM Resonse, to NRC Reqoesi tor Additionl leo rtion IRA__

IEM COW.

ITEM 3

b d

NO.

No.

DESCRIPtiON % COVERAGE CZ.21 04030 SG# MS Nole t.

86%

14% o.1i fent 0nce ot wektparriUy liriteddoeto insuliontINs located 1.Z from Menual UT exao A5gle's Used: 4YS'lS UT-ettel, SO'S So surtW0ee0amN.

UT - NRI Top Head ID-the weld oenterlin eery 24" arond the circunmtrence. 45s and e0".

GV or ecoring.

WOl where ccessible.

100% ot tIeMA E Code Required t Vol canl ttbe ohiewd de to the perrrmarant (welded) insulation bugs in the scarning ateo.

Sý 0lahe14-430.

No amern tive NDE ethods or adwetd tenhtologies -ou4d be pratically e, tWby d to eoa.ne thi area.

0" ttcmntD*30.

E anntion Coerage Profile shows askroh o the insudarion sWpport logs atd th proximiy to tIe weM.

Page 13 of 87

UMI-TED C-F-i EXAMINATIONS WV3 Responses to NRC Requst For Additional hfrtration (RAJ)

ITEM CORP.

ITEM NO.

No.

DESCRIPTION S COVERAGE a

d l5.11 $5451 8" Pipe to Vat 4s.50%

Single sided sem do to t sconfigatler Addiional Initation on pipe sidemd

, Iweld Manol UToeam Angles Wsed: 4'S, 60'RL Neaot ewnt5401.

PT-Nn tT

- NT-Weld crown. 4"s. Gl and 70'RL oed for scanning, whereaocessibie.

70RL 100% of the ASME Code Requited Volu cannot he Weti d du to the snom is single sided (pipe sde du to the ve1n See Hcartonant 05.051.

No alterhntie NDE nfhods o adnenoed t-ehnouoogies coud be proto..tmy e.ployed to eain this area.

Se.R.Chnne. S5.541.

Eamioation Coerage Profile uhows a ukalh of the angle, wed and the weld

-n limithatio.

C5.11 b4-Ot Va teMt Io Pips k0%

vrogtesided emm du to alv eonigeation. Additional Ihnlation on pipside dm to weld Manual UT exam Ange.s Used: 4"'S. O'S. See altaole-ano G 01.

PT-NRt UT-NW Weld Mow 645"s.0's and 70s.med tor scanin., whtre aessible (omponl is ess than TO' S 0.50" in rIokrussl).

100% of the ASME Code Required Vo~kne oannot be uclhoued due to the ntoo I Mshap, of the alo body and fhe weld row, on the pipe to vetn

onfhgvretioo.

See artavhnwol 04401.

No eltenoativ NE R

thods or adveaned rechrologies ovLd be practiadly etnpoyed to eeatnine thin area.

Soe atteanhmene 14-01.

Eamioatin Coveage Protile uhows the co.to ort1he pipe,.eld andur ihpeotable v1v body.

C5.11 5S t01 LPSI Vl to 10" So%

Scanning limiltd to pipe side only, d to l

OD configwation 4's,, 60'S, nd 70p'ssed Meanwl UT eo

.g 4e'sUsed:

45'S, 60S Se attelhn saf 56-01 PTNW.

UT-NW Pipe Weld tot s-nning. where aooessible (pipe nominal thieknss e 0.366').

T0' N 100%

of the ASME Codae Requred Voo e canot be achivd due to the vav to pipe coofigwatior Se attanchnent 5.01 No eterst iv NDE thods or advamed tecnwtnogieu

.oood he prfctiiley ettployed to esamnine this area.

See.ttvle 5".-e1 E

tiaon Cuvrege Protite shows a sketch of the wvat to pipe oonfignrwtior v ts.11 -2 oPSII0 Pipe to I

Soanning nitaed to pipe side ory, dly to tee 0O confiqgativar.

and T0's wed Manýal UT eoar Angle's Usd: 40'S. GO',See etr l

55402.

PT -NW.

UT-NW ss-ee'. TeevWetod Ioscsnna,,

whene acessteibl(pipe*ýi ehicksse = 0.3g65).

TO'S 100%

of the ASME Code Req.ired Vooe cannot be aehimevd due 1, the Of conto f

oI theTae (vn-purneflsrotces).

See s*nehoent 556002.

No uterRatiAI NDE mthods or advaned teohrwlgies could be practiafy erptoy'ed to e'xrnie thin aea.

See

.ttnhe.ene 56400.

E*reaination Coerage Prolde shows typical W0 conto. of Ih Tee

.vr*taratet

,fwaes) that preolode 100% inspectin of welds 564002, 56-03. 564005.

S.il 41-471 14o x Redo1 inR g

00

uuriog limitedto eltow aide onldy.

d to flange 0o ootigvatio M4-',

s0saInd 70' S danwl UT aa oMglese Ud: 4"'S, 70'Soeeuttohnnantl1471.

Nsu aean.

UT-NW Elbow to Flaete ued tot sceninog, whoetreacoessibe.

mThk fessistess then 0.50' Weld 100% oW the ASMt CoRde Requited lnVolere ce.n.t be whievd du' to the Renge 0D coohgnalion pravedinog soanninrg hi~s area*

See usach~oeotfi.U1.7 No eroariv NDOE nethods or dwanced teoohnwogies oLdd be praotioaly oployed to eoi-thi*n ea.

See attacthnent 41-070.

Coanrinahn Coverage Profgie shows the fterge ontot Imitatian.

Page 14 of 87

UMITED C-F-I EXAMINATIONS WO Responses to NRC Request Wor Additionl heo-tion (Rai ITEM COMw.

ITEM NO.

WO.

DESCRJPIN

% COVERAGE b

d C5.11 5;40n 10".1-avo 50%

scanrigredtopId popede ide on0y

d.

o I.o OD ofiggaio sandl s

edt7 t f

br anoaoTe AIngD's.

Ud: 4S.Or" No6sote ee ro U. - NRI atairdec pipe weld

.oanning where.aoes ble.

TtSý 10% o the ASME Code Reqoired Vobum c-an Dbe aoieoed d-o eI.I body 00 cootigqatioso No literneti NDE rtrods or edaed technlogies corti be prectnialy nployed to eoamin ibis area.

S taemn S5-01.

CEantmon Coorage Protile sco.s the ni., weld. and pipe profile.

CS.11 54-443 10 Pipeto 1. I 0%

Scaoning Iitd topipe idD d-to red-., OD.onfig-tio, 4S's and.d 70 e

-d f anoi-UT eoar dgls U-sd: 40S, GO-Seeuliecerol4-54.

PT-Nm.

UT-NM S. Red.er Weld scanning, where acocosible (Ies. then 0.5V ihmnkoen).

J-7TV S 100% o thed ASME Code eqoir oe Vo e -wntbe WieNdwonredderside Saa 440.

of weld doe to the 00 cmfrigu-aton.

No aisratijv NOE nethodo or ade*wed technologies could be practicaly employed to edanume hti area.

See atetachrent 544.04.

earnineion Coverage Protiie chews the noil ion af the pipý to redUCer ig.11 0-.77 S' Pipe to Co..

500%

Naningminirediio pIpe ideory. dm toOO contqwtion o peonaiionaide. 45,ad M

anI UT exao

,glesUsd:

454S, i

.e tt-l-,

a77.

PT-NR.

UT-NM Peetration Weld 901RL sd tot ena nng. ohereecceesible.

100%N ot ihe AME Code Required Vobene -annot he euaminod no the petratiOn side oW the weld do to the 0 contoor No.aterntiv NWE methods or edo-ded techoologies coudd be practicafly employed to enanoino thio area.

See anattahern ga-T77.

CEmmmmatlon Co-rege Proile shows the weld OD contour aWd the eum

overags.

CuI.11 62-o4 14" Eow to Tee 50%

hoarnning tirted to e'bow sloe ordy. dne to tee 00 anotigoatino. 40o, eta. Io'a, aid Manl UT e UAglea Aced: 4OS, b ee 5ao 0.

Nr. ree.

UT - S Weld hotRL veed rat scanning, where accesoible.

SORt. It0S r1an%

at the dOME Code Required Tok~en cannot he achieved bore the Tee side d. to the 00 conDigoation So alterntiv NOC neids or adNOnoed technlogies co.da be practicely ernpioyed to easomne this area.

e facmn 2ý04.

E--wiatlon Corage Proud hesws the 14" elbow to Tee -ontoor thot niTte the oispeotio to the pipe aide o.4y.

C501 6-11 4 ElbowITe Ta%

caing Iied d-to Tee..o pipe Vnniguration.1"totalioheswas noisanddto

-a-d ua-Te.am-A les Used:4sS Sea 60Si-N-0t..AT-N 100% at theM AME Code Required Vobame cannot he Iaichi d dm to the OD cooW (shor radios crotch area) t the 4" Tee preventd nonirg I

otihe weid.

See at, teNenent 60-1l1m So alternative SOCE worods or adoanoed technologies couda heprecaitigj employed to e ins this atee.

See attaohmenta0-131.

C-eaw~~tindln Coverage Profiie shows the contaon at the shod radive 4" Tee tnat Uirnted the exare area, Page 15 of 87

LIMITEO C-F-1 EXAMINATIONS WM Respones to NRC Regoest tot AUddtionl etI -

tin RAJ)

ITEM COMP.

ITEM NO.

No.

CEOCRIPITN COVERAGE d

c C5.21 6046C 3o Elbow to Pipe 75%

Sooreg trritedd to 50%

t%

cirehtsre on the elbow t

lebto rid reoto intrados redio. 4-45 Me tUTseoa Angle', Used: 45rU, 6S Seattaotentl048.

PT-NM.

UT-NR We 7ro osed tot soannirng, Uters a essible.

70.

100% of t.e ASME CodelRequitedoo Vrooer can*ctheehied dore to -

adit intrados on 3U etbows.

See..t..-id'Pe 60-4611.

No afterotiw NDE rootttds or adonred technotise cords be precticefly emnployed to etir thlis area.

See atricei t 60-4in.

Eoornin~troonCoosregeProlile depicttsthe srrla adirt inttrad~osCo

" etlbow tIet firils the UT eurimtio.,

CO.21 60049 Pipe to Peittation 50%

Single sWed e-n due to ninetratinni conligeation o

0.70, sneed froanoi, wterer Motor UT exaAn gle Uso

-Sd:

4",60-5 70" eestt,.iitrett-

9.

PT.NRt UTNW Weld

.. oesiblo.

100% of the ASME Codso Prqiradot Volme c ct ote chlu-d oddoe to pipe to Ses eethrrott 0-09,.

petlrettti.o conOfigation.

No tteroaive NiDE otolds Ut adoonced tehlooirges corMi be protioafly mptopyd to eO itte area.

See aaetirhent 60-49.

ECxooitro CoEose~ Ptofile UMTED R-A EXAMINATION US WM Reopooso to NRC Re-ost for Additiooetl efotcitio (RAO ITEM CMP.

ITEM NO.

No.

DESN RP1ON

% COVERAGE Uc d

R0.20 064-07 ReolttCorC*lt 89%

.rntidond duetopernrrnrototCoroceteoaddltsypeor ppott Ma IlUTe-r Ssett0.

No w-t.oe emtisinert.l UT. NWJ 42' Elbow to Pipe Earen Angle.:

Celd 100% of the ASME Cods Reqoired Vtolmne Cnnot be achiwed dm to thte 41-S, E0r petttnent spport ptso*ntirro otoses to 30" of the dow, tmo r s.ao ara and D0 Co of the o UT s.n area.

Thlere ro too aiertotio NOV metheds or edoeroned t lontologies thrt cooud be practicafy eployed Co oizodne IAME Code o-watgO.

See ttachleent 0U-"07 tot timitationo R1.20 15-411 Re.atorCU Ctat 84%

L.rted up streT scan dire to petrrleot Concrete -Mdd type spport and dow stroeam eantTl UT eo.

42" Pipe to Elbow tortitotion doe to Ssutot oo ling oot rge lnoe Eontturtioo Ern AngS.es tel tOS10

o. the ASME Code Reqoired Voto C-tt be acni.od doe to the 5S,. Dor p a i sUpport preonsing cce-to 00" ot the opetrm soco ar and 2 noZotts (20" each) initing the dowctreao s-m.

Tlhere were to afterontive NOVE otthods or adsoosed tlectlotgies that cootd be praotiCofly employed to lmozerios ASME Code coorage.

see aotachetnt 150411 tor tfjtletio*n Rt.20 CICCw to 14" 50%

Lrinjed ac.es.s single side

.oortoion doe to petotanent coioeeta saddte type iuppod

,Ernaol UT.o-.

See etteotorreot 41-144 Noeuntt o

iidsrootl. UT-NWU 21404 St aidess pipe weld Carm Aogtes:

100% o1 the ASME Code Required Vot1-e ca-1o he tchi.od dte to the pipe 45"S, E0 S rest ratd kontdiftsly dorwtreta ot the wred.

There,te to atertiteiw NDE metheds or Idoatroed te hotttlogieo that cmd b ptacticaUy etptoyed to moosrze MIME Cods coostage.

Seoee aatahernt 21404.

See elooot21404.

Page 16 of 87

a En t Entergy EXAMINATION COVERAGE PROFILE Attachment #: 02-001 0 ANO 1 1 0 ANO 2 10 GGNS 10 RBS I

W3 Component ID: 02-001 Report No.: 2000-406 Material Type: CS Configuration: RPV Head to Flange Weld Length: 191" Sch/T: 9.0" Angle's Used: 0°L, 450S. 600S.

NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 64%

SHR(

Shroud Si (12 pla(

60o 4 5 '

DUD upport 3es) 600 450 HEAD FLANGE No coverage -

Full Coverage -

60 S only -

COMMENTS: Exam coverage limited by shroud, shroud support, and flange configuration. Six inch wide lifting lugs every 300 around the circumference of the head. Shroud located 8" from the toe of the weld on the head side. Flange located 5 inches from the toe on the opposite side.

t-age I t OT 01

a

---Entergy EXAMINATION COVERAGE PROFILE Attachment #: 02-001 03 ANO 1 0 ANO 2 10 GGNS, 0 RBS IS W3 RPV Head to Flange Weld Scan Area -

Scan Limitation due to obstruction -

NOTE: This photograph is the replacement head for the Waterford III reactor vessel. The replacement head was built with the same dimensions as the original reactor vessel head.

Page 18 of 87

-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 02-002 r-ANO 1 0 ANO 2 10 GGNS 10 RBS I

W3 Component ID: 02-002,02-003 Report No.: 2000-406 Material Type: CS Weld Length: 22.1 Sch/T: 9.0" Configuration: RPV Head Peel Segment to Peel Segment Welds Angle's Used: 00L, 456S, 600S, TOTAL EXAM VOLUME OBTAINED: 18%

NOTE: This photograph shows the replacement head for the Waterford III reactor vessel. The replacement head was built with the same dimensions as the original reactor vessel head. The yellow line shows where the bottom of the shroud lands on the shroud support and prevents access to welds02-002 and 02-003. Everything above the yellow line is under the shroud and inaccessible.

Page 19 of 87

a-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 03-010 0 ANO 1 1 0 ANO 2 E1l GGNS

-10 RBS I

W3 Component ID: 03-010 Report No.:2002-238 Material Type: CS Configuration: 42" Hot Legt to SG#1 Weld Length.: 158.25 Sch/ T: 8.63" Angle's Used: 00L, 450S, 600S, NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 86.5%

03-010 Weld C.L.

Nozzle Generator Code Required Volume 45& 60 shear looking toward SG only -

60 shear only looking toward SG -

45 degree only looking away from SG -

No coverage -

Full Coverage -

U LZ Page 20 of 87

I

-Entergy EXAMINATION COVERAGE PROFILE oAN0oI JOANo2 OGGNS O RBS W3 Attachment #: 03-011 Component ID: 03-011 & 03-012 Report No.: ISI UT 08-085 Configuration: 30" Cold Leg Nozzle to SG #1 Sch/ T: 4.4" Material Type:.CS Angle's Used: 600 S. 700 NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

NOZZLE TOTAL EXAM VOLUME OBTAINED: 66%

SHELL Weld 300450 I

(

/

"I Code Required Volume 45' shear only. Looking away from SG 45' & 60' only looking toward SG 60' only looking toward SG Full Coverage D No Coverage Page 21 of 87

-Entey EXAMINATION COVERAGE PROFILE Attachment #: 04-026 0 ANO 1 0 ANO 2 10 GGNS 0 RBS U

W3 Component ID:

04-026 Pipe Diameter.:

N/A Report No.:

99-282 Sch/ T: 7.00" Material Type: CS Angle's Used: 450S. 60 0 S NOTE: The sketch below is an electronic representation of a plan view of the weld, and is not to scale.

TOTAL EXAM VOLUME OBTAINED: 56%

COMMENTS: Scan obstruction caused by 4" wide insulation support ring located 2.3' from toe of weld, 3600 around circumference.

Page 22 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 04-029 0 ANO 1

[3 ANO 2

[0 GGNS IE RBS 1

W3 Component ID:04-029 Report No.:ISl UT 05 028 Material Type: CS Weld Length.: 125" Configuration: SG#2 Top Head Torus to Top Head Dome Sch/ T: 5.5" Angle's Used: 45'S. 60°S. 0°L NOTE: The plot shown is an electronic representation of the scan depicting coverage of the stud area, the remaining area has 100% coverage. This profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 89%

14 insulation lugs 3.5" off of weld centerline 36" ap rt 60' 450

/

60'/45' Stainless steel cladding on ID Code Required Volume 45 & 60 (1) direction shear looking at Torus No coverage Full Coverage F-1 COMMENTS: Scanning limited for 11.3% of weld circumference, due to 14 insulation lugs located 3.5" from weld centerline every 36" around the circumference.

Page 23 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 04-030

[0 ANO 1 0 ANO2 1 0 GGNS 10 RBS I

W3 Component ID: 04-030 Report No.:ISI UT 05-029 Material Type: CS Configuration: SG#2 MS Nozzle to Top Head Dome Weld Length.: 125.7" Sch/ T: 5.5" Angle's Used: 45° S, 60°S. 0%L NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 86%

NOZZLE Insulation Lug 5.25" from weld center line 60'1 60 I.

I I

(

I L

,IX VESSEl Full Coverage -

60 shear only looking toward SG -

No coverage -

Full Coverage -

U D

COMMENTS: 14% of circumference of weld partially limited due to 8 insulation lugs located 5.25" from the weld centerline every 24" around the circumference. The nozzle to vessel transition (crotch) limits the exam looking away from the nozzle.

Page 24 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 05-009 0 ANO 1

[3 ANO 2 10 GGNS 03 RBS I

W3 Component ID: 05-009 Report No.: 99-194 Material Type: CS Configuration: Pressurizer Surge Nozzle to Head Sch/ T: 4.6" Angle's Used: 0°L. 45'S, 600S.

NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 64%

NOZZLE 600/450 600 450 450/6 00 HEAD Code Required Volume 45 & 60 shear looking toward SG only -

60 shear only looking toward SG -

45 degree only looking away from SG -

No coverage Full Coverage-D Page 25 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 05-010 II ANO1 0 ANO 2 1I0 GGNS r0 RBS IN W3 Component ID: 05-010 Report No.: 99-175 Material Type: CS Configuration: Pressurizer Spray Nozzle to Head Weld Length.: 52" Sch/ T: 4.4" Angle's Used: 0°L. 45°S, 60°S NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 74.8%

45° 60° 45* 60'° 5

60 45 & 60 shear looking toward SG only -

60 shear only looking toward SG -

45 degree only looking away from SG -

No coverage Full Coverage - F--

COMMENTS: Exam coverage limited by nozzle to head configuration. See the drawing above for limitations and weld coverage profile.

Page 26 of 87

Attachment#: 05-011

[3 ANO 1 0 ANO 2

[0 GGNS

[0 RBS I

W3 Component ID:05-011.05-012. 05-013 Report No.: 99-175 Configuration: Pressurizer Safety Nozzle to Head Weld Weld Length.: 52" Angle's Used: 00L, 450S. 600S Material Type: CS Sch/ T: 4.4" NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 65.9%

Nozzle HEAD 045 60' 45' 45°/60'o° Head 45 & 60 shear looking toward SG only 60 shear only looking toward SG 45 degree only looking away from SG No coverage Full Coverage Page 1 of 2 Page 27 of 87

Enterty EXAMINATION COVERAGE PROFILE Attachment #: 05-011 D ANO 1 0 ANO 2 0 GGNS 0 RBS W3 Component ID: 05-011.05-012. 05-013 I

Nozzle Weld N',

Weld #'s05-011, A

o05-012,05-013 A

Transition A = 13" limitation to the 45' Axial examination, measured circumferentially.

B = 20" limitation to the 60' Axial examination, measured circumferentially.

COMMENTS:

This plot is a typical profile for 05-011,05-012 and 05-013. Exam coverage limited by nozzle to shell configuration. The drawing above depicts the scanning limitations caused by the head to shell transition.,

11 Page 2 of 2 Page 28 of 87

SEntergy EXAMINATION COVERAGE PROFILE Attachment #: 05-014 0 ANO 1 0 ANO 2 0 GGNS

[0 RBS I

W3 Component ID: 05-014 Report No.: 99-197 Material Type: CS Configuration: Pressurizer Surge Nozzle Inner Radius Sch/ T: 4.4" Angle's Used: 60 °S, 70°S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 29.4%

t= 4.4" 700 shear only Code Required Volume No Coverage Full Coverage D COMMENTS: Scanning limited by nozzle to head transition configuration.

Page 29 of 87

M Entergy EXAMINATION COVERAGE PROFILE Attachment #: 05-015 0 ANO 1 10 ANO 2 10 GGNS 1[ RBS I

W3 Component ID: 05-015 Report No.: 99-166 Material Type: CS Configuration: Pressurizer Spray Nozzle Inner Radius Sch/ T: 4.4" Angle's Used: 600S, 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 60.4%

Nozzle t= 4.4" Vessell Head 700 shear only Code Required Volume No Coverage Full Coverage D COMMENTS: Scanning limited by nozzle to head transition configuration.

Page 30 of 87

-Entey EXAMINATION COVERAGE PROFILE Attachment #: 05-016 0 ANO 1 10 ANO 2 0[ GGNS 0 RBS I

W3 Component ID: 05-016,05-017, 05-018 Report No.: 99-1771178/179 Material Type: CS Configuration: Pressurizer Safety Nozzle Inner Radius Sch/ T: 4.4" Angle's Used: 600S, 70'S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 72%

Nozzle t =4.2" Vessel 700 shear only Code Required Volume No Coverage R

Full Coverage D-1 COMMENTS: Scanning limited by nozzle to head transition configuration.

Page 31 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 06-006 0l ANO 1

[3 ANO 2 l[ GGNS 1[ RBS I

W3 Component ID: 06-006 Report No.:

2000-302 Material Type: C/CSS Pipe Diameter.: 14" Sch/T: 1.10" Angle's Used: 450 & 600 S: 400 RL. 450 RL. 60 RL NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 86.5%

6ý° S 450/60° S CL 45°/600 S Safe End Side Nozzle Side No Coverage Full Coverage 450 S1 direction only COMMENTS: Scanning limited on nozzle side of weld due to nozzle transition.

NOTE: Per MRP-139 Inspection,26-006 had a full structural weld overlay installed in RFO-15.

Page 32 of 87

I t EXAMINATION COVERAGE PROFILE Attachment#: 06-007 0 ANO1 E3 ANO 2 3 GGNS 3 RBS N W3 Component ID: 06-007 Configuration: RCS Hot Leo Angle's Used: 45°S, 600S Report No.: ISI-UT-08-079 Pipe Diameter.:

42" Material Type: C.

Schl T: 4.04" NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 89%

'4"e.Usk.

pietZE.6

,1_1 vn I A-r~r,4 wF-L 0 COMMENTS: Limited scan due to permanent concrete saddle type support and nozzle at bottom (1800) of RCS pipe.

Page 1 of 2 Page 33 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 06-007 0 ANO 1 0 ANO 2 0 GGNS 0 RBS I

W3 NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 89%

PIPE Page 2 of 2 Page 34 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment#:07-013 0 AN*1 0 ANO2 0 GGNS ORBS I

W3 Component ID: 07-013 Report No.:

2003-379 Material Type: CS Pipe Diameter: 30" Sch/ T: 3.7" Angle's Used: 00L, 45°S & 600 S NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 82.2%

45' 450 N

Full Coverage COMMENTS: Scanning obstructed for 17.8% of weld circumference due to adjacent permanent support structure.

Page 35 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 08-008 O ANO 1 0 ANO 2 03 GGNS 0 RBS I

W3 Component ID:08-008 Report No.:2002-261 Material Type: CS Configuration: 12" Safety Ineection Nozzle to 30" RCS Loop 1A Hot Leg Sch/T: 5.5" Angle's Used: 450 S NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

/

Cut-away view

/

of nozzle / pipe

/

/'

Nozzle

.//

30" RCS Pipe/

,~/

/

12.5" loss of contact for 120'

/

Weld area Page 1 of 2 I

Page 36 of 87

IEntergy EXAMINATION COVERAGE PROFILE Attachment#: 08-008 E3 ANO 1 0 ANO 2 03 GGNS ORBS U

W3 Component ID:08-008 NOTES: The plot shown is an electronic reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

COMMENTS: Scanning limited to 30" pipe side, due to nozzle OD configuration. ID clad prevents two directional coverage, via the bounce.

Page 2 of 2 Page 37 of 87

SEntergy EXAMINATION COVERAGE PROFILE Attachment #: 08-014 0 ANO 1 0 ANO 2 0 GGNS

[3 RBS 1

W3 Component ID: 08-014 Report No.:

95-306 Material Type:

CS Pipe Diameter.: 30" Sch/ T: 3.125" Angle's Used:

400 RL 450 RL NOTES: The plot shown is an electronic reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 71%

& FE E4Ahl COMMENTS: Scan coverage limited on safe end side of weld due to short safe end length and the adjacent pump confiquration.

Page 38 of 87

-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 09-002

[3 ANO 1 0 ANO 2 0[ GGNS

[3 RBS I

W3 Component ID:

09-002 Pipe Diameter.:

30" Report No.:

2003-401 Material Type: CS Sch/T: 3.125" Angle's Used: 45°S, 60°S NOTES: The sketch shown is an electronic reproduction and not to scale.

TOTAL EXAM VOLUME OBTAINED: 87%

'N I..

4

~.-

.- ~

U

~

I' 7<

Nozzle

,Weld 09-001 Nozzle Extension Elbow Extension Weld 09-018 IWeld 09-002

-i

-~

  • '.a r'J Page 1 of 2 Page 39 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 09-002 0 ANO'1 0 ANO 2 0 GGNS 0 RBS I

W3 Component ID:

09-002 Report No.:

2003-401 Material Type: CS Pipe Diameter.:

30" Sch/T: 3.125" Angle's Used: 450S. 60°S NOTES: The plot shown is an electronic reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 87%

FLOW No Coverage -

COMMENTS: Scanning limited on elbow side of weld due to elbow OD configuration, limiting the amount of elbow side coverage.

Page 2 of 2 Page 40 of 87

S-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 09-005 r-ANO 1 0 ANO 2

[0 GGNS 0 RBS U W3 Component ID: 09-005 Pipe Diameter.: 30" Sch/ T: 3.5" Report No.:

2003-402 Angle's Used:

450 S.

Material Type:

CS NOTES: The plot shown is a reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 85%

FLa

-vP Gc,-,o cVEZ V4ELD COMMENTS: Scanning limited on elbow side of weld for 17" of circumference due to adjacent permanent support. Scanning performed across weld from pipe side, but no second direction in obstructed area due to ID cladding, which precludes bouncing sound.

Page 41 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 09-016 0 ANO 1 0 ANO 2

[0 GGNS 0 RBS U W3 Component ID:

09-016,09-017 Report No.:

2000-441 Material Type: CS Pipe Diameter.:

30" Sch/ T: 3.125" Angle's Used: 45°S, 600S, 45°RL, 60°RL,70°RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED 09-016 = 52.5%

TOTAL EXAM VOLUME OBTAINED 09-017 = 17.5%

COMMENTS: 09-016 - Scanning limited on safe end side of weld due to the width and shape of safe end.09-017 - Scanning limited on safe end side of weld due to the width and shape of safe end. Scanning on Pump side is considered "best effort" due to cast stainless steel material. 1.9% of safe end side was also obstructed by a 1" diameter nozzle.

Page 42 of 87

EEXAMINATION COVERAGE PROFILE Attachment #: 10-001 0 ANO 1 E0 ANO 2 10 GGNS 0 RBS I

W3 Component ID: 10-001 Pipe Diameter.: 30" Sch/ T: 3.125" Report No.:

2000-457 Angles used: 45°RL, 40°RL, Material Type:

CS NOTE: The plot shown is a reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 18%

SAFE END SIDE

  • =

NOZZLE SIDE 1D4 J~4~*

F---m I,

FLOW Direction #1 I-1 No Coverage Direction #2 TOTAL EXAM VOLUME OBTAINED: 18%

COMMENTS: Scanning limited on safe end side of weld due to the width and shape of safe end. Scanning on Nozzle side limited by nozzle transition.

Page 43 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 10-002 0 ANO 1 0 ANO 2 10 GGNS 0 RBS UW3 Component ID: 10-002 Pipe Diameter.: 30" Report No.:

2000-457 Material Type:

CS Sch/ T: 3.125" Angle's Used: 40°RL, 45°RL, 600RL, 450S NOTE: The plot shown is a reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 44.2%

30" RCS PIPE SAFE END SIDE (A~v.o

  • 0 -06 I;

FLOW 4

SDirection #1 No Coverage

\\

Direction #2 COMMENTS: Scanning limited on safe end side due to width and shape of safe end. Pipe side scanning limited by adjacent nozzle for 6.75" of 116" of circumference.

Page 44 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 13-001 10 ANO 1 IE ANO 2 10 GGNS

[0 RBS I

W3 Component ID: 13-001 Pipe Diameter.: 30" Report No.:

2000-474 Sch/ T: 3.5" clad Material Type:

CS Angle's Used: 450 RL NOTE: The plot shown is a reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 62.5%

WjbIP"M -ME OF WE*3-rZZ I

NoZZOW COMMENTS: Scanning limited to the Nozzle Extension side only due to the nozzle OD configuration and the proximity of weld 13-002 in the scan path for 13-001. These limitations reduced the scanning coverage 50% in one direction only.

Page 45 of 87

a Enfergy EXAMINATION COVERAGE PROFILE Attachment#: 15-006 0 ANO 1

[0 ANO 2 10 GGNS

[3 RBS I

W3 Component ID:

15-006 Report No.:

2000-421 Material Type: SS Pipe Diameter.:

2" Sch/ T: 1.071" Angle's Used: 450 S, 600S. 450 RL, 600 RL, NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 85.5%

45' CL 45' IX Flow F1 No Coverage N

Direction #1 W

1 Full Coverage COMMENTS: Examination limited on safe end side of weld due to adjacent safe end to pipe weld.

NOTE: Per MRP-139 Inspection, this weld had a full structural overlay installed in RFO-15.

Page 46 of 87

a,

-- Entergy EXAMINATION COVERAGE PROFILE Attachment #: 15-011 0 ANO 1 3 ANO 2 10 GGNS 0 RBS U

W3 Component ID: 15-011 Configuration: Pipe to 450 Elbow Angle's Used: 450S, 600 S Report No.: ISI-UT-08-080 Pipe Diameter.:

42" Material Type: CS Sch/ T: 4.14" NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 84%

COMMENTS: Limited up stream scan due to permanent Concrete saddle type support and down stream limitation due to Shutdown cooling nozzle and surge nozzle configuration.

Page 1 of 2 Page 47 of 87

I 'Enterg EXAMINATION COVERAGE PROFILE Attachment* 15-011 (3 ANOI1 0 AN02 10 GGNS MORBS UW NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 89%

F4ge t of Page 2 of 2 Page 48 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 17-033 F[ ANO 1 0 ANO 2 1E GGNS 0 RBS I

W3 Component ID: 17-033 Report No.:

97-252 Material Type: SS Pipe Diameter.:

10" Sch/ T:.325" Angle's Used: 600 RL, 70°RL.

NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 57%

70' RL CL 60° RLR Pipe Flow No Coverage Full Coverage COMMENTS Examination limited on reducer side due to taper configuration 0.8" from weld toe.

Page 49 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 19-006

[3 ANO 1 0 ANO 2 10 GGNS 0 RBS IN W3 Component ID:

19-006 Report No.: 2000-284 Material Type:

ss Pipe Diameter.: 12" Sch/ T: 140/ 1.125" Angle's Used: 450S, NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

45°S 45°S CL Pipe Side Valve Side -

Z7 No Coverage i

Full Coverage Page 50 of 87

a-- Entergy EXAMINATION COVERAGE PROFILE Attachment #: 19-008 0 ANO 1 0[ ANO 2

[3 GGNS 0n RBS IN W3 Component ID:

19-008 Report No.: 2003-439 Material Type: SS Pipe Diameter.: 12" Sch/T: 140/1.121" Angle's Used: 450S. 60°RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

60'L 45°S 60°L 45°S CL Pipe Side Valve Side F-W No Coverage W

Full Coverage COMMENTS: Scanning limited to pipe side only, due to valve OD configuration.

Page 51 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 21-004 E0 ANO 1 0 ANO 2 10 GGNS

[3 RBS I

W3 Component ID: 21-004 Configuration: Elbow to 14" pipe Angle's Used: 45°S. 600S Report No.: ISI-UT-08-038 Pipe Diameter.:

14" Material Type: SS Sch/ T: 1.27" NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

PZJ'.

RES-rAINXNT COMMENT: Limited access, single side examination due to permanent concrete saddle type support (permanent pipe restraint).

Page 52 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 21-066 Oi ANO 1

[0 ANO 2 0 GGNS 0 RBS IN W3 Component ID:

21-066 Report No.: 2000-348 Material Type: SS Pipe Diameter.: 14" SchI T: 1.094" Angle's Used: 45°S, 60°S 70°S, 70°RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

60o S & RL 60' S & RL CL PipeISd Valve Side No Coverage Full Coverage COMMENTS: Single sided examination due to valve configuration.

Page 53 of 87

SEntergy EXAMINATION COVERAGE PROFILE Attachment #: 22-023 1[ ANO 1

[0 ANO 2

[0 GGNS 10 RBS I

W3 Component ID:

22-023 Pipe Diameter.: 14" Report No.: 2000-288 Sch/ T: 1.094" Material Type: SS Angle's Used: 450S. 600S.

NOTE: The plot shown is an electronic reproduction of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 88%

ev"14d1%6 P4,gr AZe No Coverage Direction #1 S

Direction #2 COMMENTS: 10" of downstream side of the weld, near the intrados of the elbow, was not accessible due to penetration hole.

Page 54 of 87

7Entergy EXAMINATION COVERAGE PROFILE Attachment #: 25-009 0 ANO 1 0 ANO 2 0 GGNS 0 RBS 1

W3 Component ID:

25-009,25-015 Report No.: 2000-177 & 431 Material Type: SS Pipe Diameter.:

4" Sch/T: 0.438" Angle's Used: 450S, 600S, 700 S.

NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

700 70o 700 700

  • Note = Only 50% coverage was achieved from the tee side due to the branch connection O.D. blend radius.

W Tee side inaccessible area No Coverage Direction #1 Direction #2 COMMENTS:

25-009 Scanning limited to 50% circumference on tee side due to branch connection radius.

25-015: Scanning limited to 50% circumference on tee side due to branch connection radius.

Page 55 of 87

-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 25-016 3 ANO 1

0) ANO 2 13 Grand Gulf 0E River Bend 1

Waterford 3 Component ID: 25-016,25-018 Report No.: 2000-177 Material Type: SS Pipe Diameter.:

4" SchI T: 0.438" Angle's Used: 45°S, 60°S. 70° S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

C L 45°S 70' s 45°S 70' s F--

No Coverage Full Coverage COMMENTS: Single sided examination due to valve configuration.

Page 56 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 25-019 0 ANO 1 0 ANO 2 0[ GGNS 0[ RBS I

W3 Component ID: 25-019,25-020 Report No.: 2000-177 Material Type: SS Pipe Diameter.:

4" Sch/ T: 0.438" Angle's Used: 450S. 600S. 700 S NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

70' s 70' s CL 70' s 70' s Pipe Side

  • Note = Only 50% coverage was achieved from the elbow side due to the intrados radius.

77 Elbow side inaccessible area F-1 No Coverage Full Coverage COMMENTS: This plot represents the profile for components25-019 and 25-020, which are 4" pipe-to-elbow configurations. The examination is limited due to the small radius on the intrados of the elbow. The pipe side of the exam is credited for 100% coverage. See note in profile box for elbow side limitation.

Page 57 of 87

---Entergy EXAMINATION COVERAGE PROFILE Attachment #: 25-022 0 ANO 1 0 ANO 2 10 GGNS 0 RBS I

W3 Component ID:

25-022 Report No.:

2000-204 Material Type: S.

Pipe Diameter.:

4" Sch/ T: 0.438" Angle's Used: 45°S. 60'S, 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 62%

70° 70' 700 70' Only 12% coverage was achieved from the tee side due to the crotch of tee.

WTee side inaccessible area No Coverage Direction #1 Direction #2 COMMENTS: Scanning limited to 12% on tee side due to the radius of the tee.

Page 58 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 26-001

[3 ANO 1 1 0 ANO 2 10 GGNS 10 RBS I

W3 Component ID:

26-001 Report No.:

2000-479 Material Type: SS/CS Pipe Diameter.:

8" Sch/ T: 1.61" Angle's Used: 600 RL, 450 RL NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 70%

CL 450 450 Nozzle Safe E~nd Flow No Coverage Full COverage Direction #2 COMMENTS: Scanning limited on reducer side due to OD taper near the weld toe.

NOTE: Per MRP-139 Inspection,26-006 had a full structural weld overlay installed in RFO-15.

Page 59 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 26-002 0 ANO 1 03 ANO 2 10 GGNS 0 RBS IN W3 Component ID:

26-002 Report No.:

2000-171 Material Type: SS Pipe Diameter.:

8" Sch/T: 0.78" Angle's Used: 450S, 600S, 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

45' 70° CL 45/70o Reducer Side E

Side No Coverage Full Coverage COMMENTS: Scanning limited on both sides of weld due to elbow to reducer OD configuration.

Page 60 of 87

a SEntergy EXAMINATION COVERAGE PROFILE Attachment #: 26-006 El ANO 1 0

r-ANO 2 10 GGNS 0 RBS IN W3 Component ID:

26-006 Report No.:

2000-467 Material Type: SS/CS Pipe Diameter.:

8" Sch/ T: 1.61" Angle's Used: 600 RL, 450 RL, 450S NOTES: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 63%

CL 45° 45'o Nozzle Safe End Flow W

No Coverage Full Coverage Direction #2 COMMENTS: Scan coverage limited on the reducing safe end side, due to OD configuration.

NOTE: Per MRP-139 Inspection,26-006 had a full structural weld overlay installed in RFO-15.

Page 61 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 26-007

[0 ANO 1

[ ANO 2 0 GGNS 0 RBS I

W3 Component ID:

26-007 Report No.:

2000-171 Material Type: SS Pipe Diameter.:

8" Schl T: 0.78" Angle's Used: 450S, 600S. 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 52%

Y5 70' QL 45/70' Reducer Si Full Coverage F-1 No Coverage COMMENTS: Scanning limited on both side of weld due to elbow to reducer OD configuration.

Page 62 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 27-002 1[ ANO 1 10 ANO 2 10 GGNS 0[ RBS 1 U W3 Component ID: 27-002, 004, 005, 006, 007, 008, 009 Report No.: 2000-192 Material Type: SS Pipe Diameter.:

2" Schl T: 0.380" Angle's Used: 450S, 600S, 700 S. 700 RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

---*§>

Extradoses

  • Note = Only 50% coverage was achieved from the elbow side due to the intradoses of the elbow.

700 Intradoses 700 Elbow side inaccessible area 11No Coverage 0

Direction #1 COMMENTS: Scanning limited to 50% circumference on the elbow side due to the intrados radius.

Page 63 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 27-010 0 ANO 1 0 ANO 2 10 GGNS 0 RBS I

W3 Component ID: 27-010,27-011, 27-038 Report No.: 2000-294 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.380" Angle's Used: 450S, 60°S, 700S. 70;RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

60°s 70'RL CL 700 RL 60's

-Extradoses Pipe Side

  • Note = Only 50% coverage was achieved from the elbow side due to the intradoses of the elbow.

I ntradoses Pipe Side D

Elbow side inaccessible area Fi No Coverage Direction #1 Direction #2 COMMENTS: Scanning limited to 50% circumference on the elbow side due to the intrados radius.

Page 64 of 87

---Entergy EXAMINATION COVERAGE PROFILE Attachment #: 27-037 0 ANO 1 0 ANO 2 0[ GGNS 0 RBS I

W3 Component ID: 27-037 Report No.: 2000-294 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0. 380" Angle's Used: 450S, 60°S, 700S, 700 RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 62%

TEE

' i PIPE Only 12% coverage was achieved from the tee side due to the crouch of tee.

D Tee side inaccessible area No Coverage Full Coverage COMMENTS: Scanning limited to 12% on tee side due to the radius of the tee.

j Page 65 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 27-054 0 ANO 1 03 ANO 2 1[ GGNS 0 RBS 1

W3 Component ID: 27-054,27-055 Report No.: 2000-303 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.380" Angle's Used: 450S, 600S. 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

60' s 70o s CL 60' s 60's Extradoses Pipe Side

  • Note = Only 50% coverage was achieved from the elbow side due to the intrados of the elbow.

6010 Intradoses

\\

  • 70' Pipe Side WElbow inaccessible area F-No Coverage Full Coverage COMMENTS: Scanning limited to 50% circumference on the elbow side due to the intrados radius.

Page 66 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 28-001 11 ANO 1 0 ANO 2 10 GGNS 0 RBS I

W3 Component ID: 28-001,28-002, 28-008,28-009, 28-077,28-078 Report No.: 2000-161 Material Type: SS Pipe Diameter.:

2" SchI T: 0.380" Angle's Used: 45°S. 60°S. 70° S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

70° s 70' s

-:CL 70° s 60'° Extradoses Pipe Side

  • Note = Only 50% coverage was achieved from the elbow side due to the intradoses of the elbow.

7'70 Intradoses Pipe Side W Elbow side inaccessible area F-No Coverage Full Coverage COMMENTS: Scanning limited to 50% circumference on the elbow side due to the intrados radius.

Page 67 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 28-012 r-ANO 1 0

1] ANO 2 01 GGNS 0 RBS I

W3 Component ID: 28-012 Report No.: 2000-162 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.480" Angle's Used: 45S°, 600S, 700 S NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 70%

450 600 450 700 Tee Pipe

~Clamp

  • Note = Only 50% coverage was achieved from the tee side due to the crotch of tee. Only 90%

coverage was achieved from pipe side due to clamp.

W Tee side inaccessible area 7

]

No Coverage Full Coverage COMMENTS: Scanning limited to 50% circumference on tee side due to branch connection radius. Scanning limited to 90% on pipe side due to an adjacent clamp.

Page 68 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 28-013 0 ANO 1 0 ANO 2 10 GGNS 0 RBS I

W3 Component ID: 28-013,28-074, 28-075 Report No.: 2000-161 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.380" Angle's Used: 45°S, 60°S, 70' S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

700 70*

707 70 70.

  • Note =Only 50% coverage was achieved from the tee side due to the crouch of tee.

Tee side inaccessible area W

No Coverage Direction #1

-Direction #2 COMMENTS:

Scanning limited to 50% circumference on tee side due to branch connection radius.

Page 69 of 87

Entergy EXAMINATION COVERAGE PROFILE Attachment #: 28-016

[3 ANO 1 10 ANO 2 03 GGNS 0 RBS I

W3 Component ID: 28-016 Report No.: 2000-162 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.480" Angle's Used: 450S, 60°S. 700 S NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 51%

450 600 450 700 Tee Pipe

~Clamp

  • Note = Only 12% coverage was achieved from the tee side due to the crouch of tee. Only 90% coverage was achieved from the pipe side due to clamp.

Tee side inaccessible area F1 No Coverage Full Coverage COMMENTS:

Scanning limited to 12% on tee side due to the radius of the tee. Scanning limited to 90% on branch connection side due to an adjacent clamp.

Page 70 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 28-076 03 ANO 1

[3 ANO 2 10 GGNS 0J RBS I

W3 Component ID: 28-076 Report No.: 2000-161 Material Type: SS Pipe Diameter.:

2" Sch/ T: 0.380" Angle's Used: 450S. 600S, 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 62%

7 0

  • 7 0 '

7 0

  • 0 Tee Pipe
  • Note = Only 12% coverage was achieved from the tee side due to the crotch of tee.

Tee side inaccessible area F-1 No Coverage Full Coverage COMMENTS: Scanning limited to 12% on tee side due to the radius of the tee.

Page 71 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 52-004 0 ANO 1

[3 ANO 2 0[ GGNS

[3 RBS IN W3 Component ID:

52-004 Report No.:

ISI-UT-05-044 Material Type: SS Pipe Diameter.:

14" Sch/T: 1.14" Angle's Used: 45°S, 60*S. 60RL, 70'S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

700 RL CL 60° S 45' S Pipe Tee side Flow F-1 No Coverage Full Coverage COMMENTS: Scanning limited to elbow side only, due to tee OD configuration.

Page 72 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 54-043 0 ANO 1 0 ANO 2 0[ GGNS

[3 RBS I

W3 Component ID:

54-043 Report No.:

2003-154 Material Type: SS Pipe Diameter.:

10" Sch/T:.325" Angle's Used: 450 S, 600 RL, 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

70o RL CL

  • L45S '60' S

Pipe I U10' X 6" Reducer Flow F7 No Coverage Full Coverage COMMENTS: Scanning limited to pipe side due to reducer OD configuration. No coverage on the down stream side due to OD configuration.

Page 73 of 87

- Entergy EXAMINATION COVERAGE PROFILE Attachment #: 54-074 0 ANO 1 0 ANO 2 10 GGNS 0 RBS T

W3 Component ID:

54-074 Report No.:

ISI UT 07-009 Material Type: SS Vessel Diameter.:

45" Sch/T: 1.56" Angle's Used: 450 S, 600 S, 700 RL

==

Description:==

Shut Down Coolinq Heat Exchanqer "B" Shell to Flanqe Weld NOTE: This is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 88%

Flange to shell Weld Exam Area Flange COMMENTS: Configuration of top and bottom nozzle saddle weld and the horizontal shell weld limit this exam. Scanning the circumferential Flange to shell weld on the SDC "B" Hx is limited by the nozzle reinforcement pads welded to the shell of the hx at the 00 and 1800.

The short neck flange itself creates additional scanning limitations for 3600 around this weld.

Page 1 of 2 Page 74 of 87

a

-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 54-074 10 ANO 1 0 ANO 2 1[ GGNS 1 [3 RBS IN W3 Component ID:

54-074 I COMMENTS: This is typical on the top and bottom of the vessel (0' and 1800).

Page 2 of 2 Page 75 of 87

SEnter EXAMINATION COVERAGE PROFILE Attachment #: 54-075 10 ANO 1 0 ANO 2 10 GGNS 10 RBS I

W3 Component ID:

54-075 Report No.:

ISI UT07-010 Vessel Diameter.:

45" Sch/T: 1.56" Angle's Us

==

Description:==

Shut Down Cooling Heat Exchanger "B" Tube sheet to Shell Weld Material Type: SS ed: 450 S. 600 S. 70* RL NOTE: This is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 85%

Nozzle Reinforcement Pads Shut Down Cooling Hx Shell to tube sheet weld Flange COMMENTS: Configuration of top and bottom nozzle saddle weld and the horizontal shell weld limit this exam. Scanning the circumferential Flange to shell weld on the SDC "B" Hx is limited by the Nozzle reinforcement pads welded to the shell of the hx at the 00 and 1800.

The short neck flange itself creates additional scanning limitations for 3600 around this weld.

Page 1 of 2 Page 76 of 87

a =t-En tergy EXAMINATION COVERAGE PROFILE Attachment #: 54-075 1 0ANO 1I 1 0ANO 2 1 0GGNS 1 0RBS I

W3

==

Description:==

Shut Down Cooling Heat Exchanger "B" Tube sheet to Shell Weld Reinforcement Pad Weld 54-075 Shell to tube sheet COMMENTS: The top and bottom nozzle reinforcement pads limit scanning the circumferential Tube sheet to shell weld. Nozzle reinforcement pads are located at the top and bottom (00 and 1800) of the heat exchanger.

Page 2 of 2 Page 77 of 87

a-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 55-001 0 ANO 1 1[ ANO 2 0[ GGNS

[3 RBS I

W3 Component ID: 55-001 Report No.: ISI-UT-07-003 Material Type: SS Configuration: Valve to o10" pipe Pipe Diameter.:

10" Sch/ T:.365" Angle's Used: 45°S, 60°RL, 70°RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

Valve CL 70° sP45e W

No Coverage U

Full coverage Page 78 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 55-051 0 ANO 1 IE ANO 2 11 GGNS 10 RBS 1

W3 Component ID: 55-051 Report No.: 99-244 Material Type: S.S Configuration: 8" Pipe to Valve Pipe Diameter.:

8" Sch/ T: 0.719" Angle's Used: 45*S, 60°L. 700 L NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 45.5%

CL 45°S 70* L Valve.

.[

  • Pipe FLOW No Coverage Full Coverage 60°L & 700 L only COMMENTS: Single sided exam due to valve configuration. Additional limitation on pipe side due to weld crown.

Page 79 of 87

a -Entery EXAMINATION COVERAGE PROFILE Attachment#: 56-001 0 ANO 1 0 ANO 2 0 - GGNS 0 RBS I

W3 Component ID: 56-001 Report No.: 2003-018 Material Type: SS Configuration: Valve to 10" pipe Pipe Diameter.:

10" Schl T:.365" Angle's Used: 450S. 60'S, 700 S NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

CL 70' s 45°S Valve

  • Pp F 1 No Coverage Full Coverage COMMENTS: Scanning limited to pipe side only, due to valve OD configuration.

Page 80 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 56-002 0 ANO 1 0 ANO 2 03 GGNS

[0 RBS I

W3 Component ID: 56-002,56-003, 56-005 Report No.: 2003-018 Material Type: SS Configuration: 10" pipe to Tee Pipe Diameter.:

10" Sch/ T:.365" Angle's Used: 45°S, 60°S. 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

F-No Coverage Full Coverage COMMENTS: Scanning limited to pipe side only due to tee OD configuration.

Page 81 of 87

a Entergy EXAMINATION COVERAGE PROFILE Attachment #: 56-077 0 ANO 1 0 ANO 2 0 GGNS 0 RBS IN W3 Component ID:

56-077 Report No.:

2000-153 Material Type: SS Pipe Diameter.:

8" SchiT: 0.80" Angle's Used: 450 S. 600 RL NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

CL 600 RL 45' S Pipe Containment Penetration Flow No Coverage Full Coverage COMMENTS: Scanning limited to pipe side only, due to OD configuration of penetration side.

Page 82 of 87

a Entfegy EXAMINATION COVERAGE PROFILE Attachment #: 60-131 0 ANO 1 0E ANO 2 0[ GGNS

[O RBS IN W3 Component ID: 60-131 Report No.: 2003-047.

Material Type: SS Pipe Diameter.:

4" Sch/ T: 0.438" Angle's Used: 450S, 600S. 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 79%

7Q0*s 70's C.L ELBOW TEE FLOW

  • Note = Only 57% coverage was achieved from the Tee side due to the OD contour. (50% X.57 = 29%)

No Coverage

/

Full Coverage COMMENTS: Scanning limited due to Tee to pipe configuration, 6" total inches was not scanned due to interference.

Page 83 of 87

a-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 60-468 0 ANO 1 IE ANO 2 1J GGNS 0 RBS IN W3 Component ID: 60-468 Report No.: 2000-252 Material Type: SS Pipe Diameter.:

3" Sch/ T: 0.438" Angle's Used: 450S, 600S. 700 S NOTE: The plot shown is a representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 75%

70' s 70° s CL 70* s 70* s Pipe Side Elbow

  • Note = Only 50% coverage was achieved from the elbow side due to the intrados radius.

Z Elbow side inaccessible area No Coverage Full Coverage

[

COMMENTS: Scanning limited to 50% circumference on the elbow side due to the intrados radius.

Page 84 of 87

a

- Entew EXAMINATION COVERAGE PROFILE Attachment #: 60-469 0J ANO 1

[3 ANO 2 10 GGNS 0 RBS I

W3 Component ID:

60-469 Report No.:

2000-252 Material Type: SS Pipe Diameter.:

3" Schl T: 0.44" Angle's Used: 450S, 60°S 700 S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

CL 70* S 70* S Penetration Side Pipe Side F

No Coverage Full Coverage COMMENTS: Single sided exam due to penetration configuration.

Page 85 of 87

a-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 61-071 0 ANO 1

[3 ANO 2

[0 GGNS 0 RBS I

W3 Component ID:

61-071 Report No.:

ISI UT 06-003 Material Type: SS Pipe Diameter.:

8" Sch/ T: 0.80" Angle's Used: 45°S. 70°S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

CL 450 S 70* RL 14" x 8" Reducing Elbow Flange Flow FI1 No Coverage Full Coverage COMMENTS: Scanning limited to elbow side only, due to flange OD configuration.

Page 86 of 87

-Entergy EXAMINATION COVERAGE PROFILE Attachment #: 64-001 0 ANO 1 0 ANO 2 10 GGNS 03 RBS I

W3 Component ID:

64-001 Report No.:

2000-063 Material Type: SS Pipe Diameter.:

10" Sch/ T: 0.365" Angle's Used: 450S. 600S 700S NOTE: The plot shown is an electronic representation of the actual profile and not to scale.

TOTAL EXAM VOLUME OBTAINED: 50%

C;L 70' S 70' S Valve Side Pipe Side No Coverage Full Coverage COMMENTS: Single sided exam due to valve configuration. Additional limitation on pipe side due to weld crown.

Page 87 of 87