CP-200901404, Core Operating Limits

From kanterella
(Redirected from ML093140096)
Jump to navigation Jump to search
Core Operating Limits
ML093140096
Person / Time
Site: Comanche Peak 
Issue date: 11/02/2009
From: Madden F
Luminant Generation Co, Luminant Power
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CP-200901404, TXX-09129 ERX-09-001, Rev 0
Download: ML093140096 (24)


Text

Luminant Rafael Flores Senior Vice President

& Chief Nuclear Officer rafael.flores@Luminant.com Luminant Power P 0 Box 1002 6322 North FM 56 Glen Rose, TX 76043 T 254 897 5550 C 817 559 0403 F 254 897 6652 CP-200901404 TXX-09129 Ref:

Tech. Spec. 5.6.5 November 2, 2009 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION DOCKET NO. 50-446 CORE OPERATING LIMITS REPORTS

Dear Sir or Madam:

Enclosed is the Core Operating Limits Reports for Comanche Peak Steam Electric Station, herein referred to as Comanche Peak Nuclear Power Plant (CPNPP) Unit 2, Cycle 12. This report is prepared and submitted pursuant to Technical Specification 5.6.5.

This communication contains no new licensing basis commitments regarding CPNPP Units 1 and 2. Should you have any questions, please contact Mr. J. D. Seawright at (254) 897-0140.

Sincerely, Luminant Generation Company LLC Rafael Flores By:

A, 27 h,,

/Fred W. Madden Director, Oversight & Regulatory Affairs c -

E. E. Collins, Region IV B. K. Singal, NRR Resident Inspectors, Comanche Peak A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon ' Palo Verde San Onofre
  • South Texas Project ' Wolf Creek A CMY.ý I

ERX-09-001, Rev.

0 CPNPP UNIT 2 CYCLE 12 CORE OPERATING LIMITS REPORT September 2009 Prepared Date:

\\Jo than M. Ralston P ncipal Engineer, Westinghouse Electric Co.

Reviewed:

'. 4.

Date:

9-23, Daniel E.

Brozak Principal Engineer, Westinghouse Electric Co.

Reviewed:

Date:

q/*j' evin N. RaTand Principal Engineer, Westinghouse Electric Co.

Approved:

41/_

Date:

op/2J/O 0oo0 I

P.

W.4James Boq~wright, Manager Westinghouse Engineering Services - Texas

DISCLAIMER The information contained in this report was prepared for the specific requirement of Luminant Generation Company LLC and may not be appropriate for use in situations other than those for which it was specifically prepared.

Luminant Generation Company LLC PROVIDES NO WARRANTY HEREUNDER, EXPRESS OR

IMPLIED, OR STATUTORY, OF ANY KIND OR NATURE WHATSOEVER, REGARDING THIS REPORT OR ITS USE, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES ON MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

By making this report available, Luminant Generation Company LLC does not authorize its use by others, and any such use is forbidden except with the prior written approval of Luminant Generation Company LLC. Any such written approval shall itself be deemed to incorporate the disclaimers of liability and disclaimers of warranties provided herein.

In no event shall Luminant Generation Company LLC have any liability for any incidental or consequential damages of any type in connection with the use, authorized or unauthorized, of this report or of the information in it.

ii ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 TABLE OF CONTENTS DISCLAIMER ii TABLE OF CONTENTS.

iii LIST OF TABLES iv LIST OF FIGURES v

SECTION PAGE 1.0 CORE OPERATING LIMITS REPORT 1

2.0 OPERATING LIMITS 2

2.1 SAFETY LIMITS 2

2.2 SHUTDOWN MARGIN 2

2.3 MODERATOR TEMPERATURE COEFFICIENT 2

2.4 ROD GROUP ALIGNMENT LIMITS 3

2.5 SHUTDOWN BANK INSERTION LIMITS 3

2.6 CONTROL BANK INSERTION LIMITS.........................

4 2.7 PHYSICS TESTS EXCEPTIONS MODE 2 4

2.8 HEAT FLUX HOT CHANNEL FACTOR 4

2.9 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR................

5 2.10 AXIAL FLUX DIFFERENCE................................

.6 2.11 REACTOR TRIP SYSTEM INSTRUMENTATION 6

2.12 RCS PRESSURE, TEMPERATURE, AND FLOW DEPARTURE FROM NUCLEATE BOILING LIMITS 7

2.13 \\BORON CONCENTRATION...................................

8

3.0 REFERENCES

8 iii ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 LIST OF TABLES TABLE 1

FQ (Z)

MARGIN DECREASES IN EXCESS OF 2% PER 31 EFPD PAGE 9

iv ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 LIST OF FIGURES FIGURE PAGE 1

REACTOR CORE SAFETY LIMITS 10 2

ROD BANK INSERTION LIMITS VERSUS THERMAL POWER 11 3

K(Z)

NORMALIZED FQ(Z)

AS A FUNCTION OF CORE HEIGHT 12 4

W(Z)

AS A FUNCTION OF CORE HEIGHT -

(150 MWD/MTU) 13 5

W(Z)

AS A FUNCTION OF CORE HEIGHT (4,000 MWD/MTU) 14 6

W(Z)

AS A FUNCTION OF CORE HEIGHT (7,000 MWD/MTU) 15 7

W(Z)

AS A FUNCTION OF CORE HEIGHT -

(11,000 MWD/MTU) 16 8

W(Z)

AS A FUNCTION OF CORE HEIGHT -

(20,000 MWD/MTU) 17 9

AXIAL FLUX DIFFERENCE LIMITS AS A FUNCTION OF RATED THERMAL POWER 18 V

ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for CPNPP UNIT 2 CYCLE 12 has been prepared in accordance with the requirements of Technical Specification 5.6.5.

The Technical Specifications affected by this report are listed below:

SL 2.1 LCO 3.1.1 LCO 3.1.3 LCO 3.1.4 LCO 3.1.5 LCO 3.1.6 LCO 3.1.8 LCO 3.2.1.2 LCO 3.2.2 LCO 3.2.3.2 LCO 3.3.1 LCO 3.4.1 LCO 3.9.1 SAFETY LIMITS SHUTDOWN MARGIN MODERATOR TEMPERATURE COEFFICIENT ROD GROUP ALIGNMENT LIMITS SHUTDOWN BANK INSERTION LIMITS CONTROL BANK INSERTION LIMITS PHYSICS TESTS EXCEPTIONS MODE 2 HEAT FLUX HOT CHANNEL FACTOR NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR AXIAL FLUX DIFFERENCE REACTOR TRIP SYSTEM INSTRUMENTATION RCS PRESSURE, TEMPERATURE, AND FLOW DEPARTURE FROM NUCLEATE BOILING LIMITS BORON CONCENTRATION 1

ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections.

These limits have been developed using the NRC-approved methodologies specified in Technical Specification 5.6.5b, Items 1, 2, 14, 16 and 21 through 29.

These limits have been determined such that all applicable limits of the safety analysis are met.

2.1 SAFETY LIMITS (SL 2.1) 2.1.1 In MODES 1 and 2, the combination of thermal power, reactor coolant system highest loop average temperature, and pressurizer pressure shall not exceed the safety limits specified in Figure 1.

2.2 SHUTDOWN MARGIN (SDM)

(LCO 3.1.1) 2.2.1 The SDM shall be greater than or equal to 1.3% Ak/k in MODE 2 with Keff < 1.0, and in MODES 3, 4,

and 5.

2.3 MODERATOR TEMPERATURE COEFFICIENT (MTC)

(LCO 3.1.3) 2.3.1 The MTC upper and lower limits, respectively, are:

The BOL/ARO/HZP-MTC shall be less positive than +5 pcm/°F.

The EOL/ARO/RTP-MTC shall be less negative than -40 pcm/*F.

2 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.3.2 SR 3.1.3.2 The MTC surveillance limit is:

The 300 ppm/ARO/RTP-MTC shall be less negative than or equal to -31 pcm/*F.

The 60 ppm/ARO/RTP-MTC shall be less negative than or equal to -38 pcm/°F.

where:

BOL stands for Beginning of Cycle Life ARO stands for All Rods Out HZP stands for Hot Zero THERMAL POWER EOL stands for End of Cycle Life RTP stands for RATED THERMAL POWER 2.4 ROD GROUP ALIGNMENT LIMITS (LCO 3.1.4) 2.4.1 The SDM shall be greater than or equal to 1.3% Ak/k in MODES 1 and 2.

2.5 SHUTDOWN BANK INSERTION LIMITS (LCO 3.1.5) 2.5.1 The shutdown rods shall be fully withdrawn.

Fully withdrawn shall be the condition where shutdown rods are at a position within the interval of 218 and 231 steps withdrawn, inclusive.

3 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.6 CONTROL BANK INSERTION LIMITS (LCO 3.1.6) 2.6.1 The control banks shall be limited in physical insertion as shown in Figure 2.

2.6.2 The control banks shall always be withdrawn and inserted in the prescribed sequence.

For withdrawal, the sequence is control bank A, control bank B, control bank C, and control bank D.

The insertion sequence is the reverse of the withdrawal sequence.

2.6.3 A 115 step Tip-to-Tip relationship between each sequential control bank shall be maintained.

2.7 PHYSICS TESTS EXCEPTIONS MODE 2 (LCO 3.1.8) 2.7.1 The SDM shall be greater than or equal to 1.3% Ak/k in MODE 2 during PHYSICS TESTS.

2.8 HEAT FLUX HOT CHANNEL FACTOR (F. (Z)

(LCO 3.2.1.2)

RTP F

Q 2.8.1 FQ(Z)

-<(K (Z)] for P > 0.5 P

RTP FQ FQ (Z)

0.5 where

P =

RATE

[K(Z)] for P S 0.5

£HERMAL POWER

D THERMAL POWER 4

ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.8.2 F

= 2.50 2.8.3 K(Z) is provided in Figure 3.

2.8.4 Elevation and burnup dependent W(Z) values are provided in Figures 4, 5,

6, 7 and 8.

The burnup dependent values can be used to interpolate or extrapolate (via a three point fit) the W(Z) at a particular burnup.

2.8.5 SR 3.2.1.2.2 If the two most recent FQ (Z) evaluations show an increase in the expression maximum over Z

[ FQC(Z)

/ K(Z)

],

the burnup dependent values in Table 1 shall be used instead of a constant 2% to increase FQW(Z) per Surveillance Requirement 3.2.1.2.2.a. A constant factor of 2% shall be used for all cycle burnups that are outside the range of Table 1.

2.9 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR (FNAHI (LCO 3.2.2) 2.9.1 FNAH

-5 FRTPAH

[1 + PFAH (l-P)]

where:

P =

THERMAL POWER RATED THERMAL POWER 2.9.2 FRTPAH =

1.60 for all Fuel Assembly Regions 2.9.3 PFAH

=

0.3 5

ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.10 AXIAL FLUX DIFFERENCE (AFD)

(LCO 3.2.3.2) 2.10.1 The AFD Acceptable Operation Limits are provided in Figure 9.

2.11 REACTOR TRIP SYSTEM (RTS)

INSTRUMENTATION (LCO 3.3.1) 2.11.1 The numerical values pertaining to the Overtemperature N-16 reactor trip setpoint are listed below; K,

= 1.15 K2

= 0.0139 /°F K3

= 0.00071 /psig T° o

= indicated loop specific Tc at Rated Thermal Power, OF P'

  • 2235 psig T,

t 10 sec T 2 3 sec f1 (Aq) = -2.78

{(q,-qb)

+ 18%}

when (q,-q,) < -18% RTP

= 0%

when -18% RTP < (qt-q,) < +10.0% RTP

= 2.34 - {(qt-qb) -

10.0%}

when (qt-qb) 2 +10.0% RTP 6

ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.12 RCS PRESSURE, TEMPERATURE, AND FLOW DEPARTURE FROM NUCLEATE BOILING (DNB)

LIMITS (LCO 3.4.1) 2.12.1 RCS DNB parameters for pressurizer pressure, RCS average temperature, and RCS total flow rate shall be within the surveillance limits specified below:

2.12.2 SR 3.4.1.1 Pressurizer pressure

Ž 2220 psig (4 channels) 2 2222 psig (3 channels)

The pressurizer pressure limits correspond to the analytical limit of 2205 psig used in the safety analysis with allowance for measurement uncertainty.

These uncertainties are based on the use of control board indications and the number of available channels.

2.12.3 SR 3.4.1.2 RCS average temperature 5

592 *F (4 channels) 591 °F (3 channels)

The RCS average temperature limits correspond to the analytical limit of 595.2 'F which is bounded by that used in the safety analysis with allowance for measurement uncertainty.

These uncertainties are based on the use of control board indications and the number of available channels.

7 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 2.12.4 SR 3.4.1.3 The RCS total flow rate shall be

  • 408,000 gpm.

2.12.5 SR 3.4.1.4 The RCS total flow rate based on precision heat balance shall be > 408,000 gpm.

The required RCS flow, based on an elbow tap differential pressure instrument measurement prior to MODE 1 after the refueling outage, shall be greater than 327,000 gpm.,

2.13 BORON CONCENTRATION (LCO 3.9.1) 2.13.1 The required refueling boron concentration is ý1881 ppm.

3.0 REFERENCES

Technical Specification 5.6.5.

8 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 Table 1 FQ(Z)

MARGIN DECREASES IN EXCESS OF 2% PER 31 EFPD Cycle Maximum Decrease Burnup In FQ (Z)

MARGIN (MWD/MTU)

(Percent) 1233 1449 1666 4698 4914 5131 5347 5564 5780 5997 6214 6430 6647 8379 8596 8812 9029 9245 9462 9678 9895 10111 10328 10545 10761 10978 11194 11411 2.00 2.15 2.00 2.00 2.05 2.43 2.53 2.48 2.39 2.29 2.18 2.05 2.00 2.00 2.06 2.21 2.37 2.51 2.57 2.60 2.61 2.59 2.55 2.47 2.31 2.14 2.04 2.00 Note: All Cycle burnups outside the range of the table shall use a constant 2% decrease in F0 (Z) margin for compliance with the 3.2.1.2.2.a Surveillance Requirements.

Linear interpolation is acceptable to determine the FQ(Z) margin decrease for cycle burnups which fall between the specified burnups.

9 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 Figure 1 Reactor Core Safety Limits 680 660 640 S620 I-0 600 580 560 0

20 40 60 80 100 Percent of Rated -Thermal Power 120 140 10 ERX-09-001, Rev.

0

240 220 200 180

.c 160 4J

  • 140 4.3 120 z0 H

E-1 H 100 0

80 80 S60 COLR for CPNPP Unit 2 Cycle 12 FIGURE 2 ROD BANK INSERTION LIMITS VERSUS THERMAL POWER


vi'....

x

'.15.32 8

(79.6,21 8) i-o

--10,164)3 o-/

- ~~

~

P -.

. -(1 00,146)

BBANKC

- - - -BANK D

H0,49)

-~~~

ý31, I

40 20 0

0 10 20 30 40 50 60 70 80 90 100 PERCENT OF RATED THERMAL POWER NOTES:

1.

Fully withdrawn shall be the condition where control rods are at a position within the interval of 218 and 231 steps withdrawn, inclusive.

2.

Control Bank A shall be fully withdrawn.

11 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 3 K(Z)

NORMALIZED FQ(Z)

AS A FUNCTION OF CORE HEIGHT N

0 rz 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 (0. 01 1 ' 0)

(6.0,1.0)

(,12.-,01,0.925)

H 0

1 BOTTOM 2

3 4

5 6

7 8

9 10 11 12 CORE HEIGHT (FEET)

TOP Axial Node 61 60 59 58 57 56 55 54 K(Z) 0.9250 0.9275 0.9300 0.9325 0.9350 0.9375 0.9400 0.9425 Axial Node K (Z) 53 0.9450 52 0.9475 51 0.9500 50 0.9525 49 0.9550 48 0.9575 47 0.9600 46 0.9625 Core Height (ft)

=

12 Axial Axial Node K (Z)

Node K (Z) 45 0.9650 37 0.9850 44 0.9675 36 0.9875 43 0.9700 35 0.9900 42 0.9725 34 0.9925 41 0.9750 33 0.9950 40 0.9775 32 0.9975 39 0.9800 1 -

31 1.0000 38 0.9825 (Node -

1)
  • 0.2 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 4 W(Z)

AS A FUNCTION OF CORE HEIGHT (150 MWD/MTU) 1.650 1.600 1.550 1.500 1.450 N 1.400 1.350 1.300 1.250 1.200 1.150 1.100 1.050 1.000 1

I1 t

m

-Iz 1=11-1 1

1z~cz Eý S.

0 1

2 3

4 5

6 7

8 9

10 11 12 BOTTOM CORE HEIGHT (FEET)

Axial Node 58 -

61 57 56 55 54 53 52 51 50 49 48 47 46 45 w(Z) 1.3589 1.3421 1.3280 1.3156 1.3027 1.2845 1.2606 1.2336 1.2054 1.1763 1.1511 1.1460 1.1469 Axial Node 44 43 42 41 40 39 38 37 36 35 34 33 32 31 w(Z) 1.1542 1.1632 1.1699 1.1774 1.1839 1.1880 1.1903 1.1918 1.1920 1.1901 1.1862 1.1804 1.1728 1.1640 Axial Node 30 29 28 27 26 25 24 23 22 21 20 19 18 17 w(Z) 1.1577 1.1570 1.1628 1.1725 1.1813 1.1888 1.1953 1.2006 1.2050 1.2085 1.2111 1.2130 1.2142 1.2156 Axial Node 16 15 14 13 12 11 10 9

8 7

6 5

1 - 4 TOP w(Z) 1.2306 1.2516 1.2702 1.2892 1.3090 1.3297 1.3501 1.3691 1.3865 1.4014 1.4133 1.4237 Core Height (ft)

= (Node -

1)
  • 0.2 13 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 5 W(Z)

AS A FUNCTION OF CORE HEIGHT (4,000 MWD/MTU) 1.650 1.600 1.550 1.500 1.450 N 1.400 1.350 1.300 1.250 1.200 1.150 1.100 1.050 1.000 I

I I

I VH\\

I --4

\\

%11 1 - I F-

-A

-/

0 1

2 3

4 5

6 7.

8 9

10 11 12 BOTTOM CORE HEIGHT (FEET)

Axial Node 58 -

61 57 56 55 54 53 52 51 50 49 48 47 46 45 w(Z) 1.4243 1.4114 1.3933

.1.3704 1.3444 1.3155 1.2847 1.2523 1.2272 1.2106 1.1923 1.1732 1.1619 Axial Node 44 43 42 41 40 39 38 37 36 35 34 33 32 31 w(Z) 1.1598 1.1600 1.1601 1.1609 1.1611 1.1600 1.1574 1.1532 1.1474 1.1413 1.1363 1.1322 1.1277 1.1233 Axial Node 30 29 28 27 26 25 24 23 22 21 20 19 18 17 w(Z) 1.1239 1.1317 1.1433 1.1535 1.1628 1.-1713 1.1788 1.1854 1.1912 1.1958 1.2012 1.2088 1.2188 1.2316 Axial Node 16 15 14 13 12 11 10 9

8 7

6 5

1 -

4 TOP w(Z) 1.2487 1.2734 1.3036 1.3331 1.3626 1.3916 1.4197 1.4462 1.4707 1.4922 1.5094 1.5247 Core Height (ft)

= (Node-

1)
  • 0.2 14 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 6 W(Z) AS A FUNCTION OF CORE HEIGHT (7,000 MWD/MTU) 1.650 1.600 1.550 1.500 1.450 N 1.400 1.350 1.300 1.250 1.200 1.150 1.100 1.050 1.000 0

1 2

3 4

5 6

7 8

9 10 11 12 BOTTOM Axial Node W(Z) 58 - 61 57 1.4158 56 1.4057 55 1.3898 54 1.3731 53 1.3601 52 1.3468 51 1.3310 50 1.3118 49 1.2899 48 1.2656 47 1.2419 46 1.2294 45 1.2253 CORE HEIGHT (FEET)

Axial Node 44 43 42 41 40 39 38 37 36 35 34 33 32 31 w(Z) 1.2224 1.2166 1.2082 1.1998 1.1941 1.1888 1.1824 1.1776 1.1708 1.1619 1.1514 1.1394 1.1275 1.1223 Axial Node 30 29 28 27 26 25 24 23 22 21 20 19 18 17 w (Z) 1.1192 1.1181 1.1228 1.1310 1.1386 1.1451 1.1511 1.1562 1.1608 1.1649 1.1682 1.1723 1.1791 1.1869 Axial Node 16 15 14 13 12 11 10 9

8 7

6 5

1 -4 TOP w(Z) 1.1986 1.2187 1.2447 1.2699 1.2952

1. 3202
1. 3443 1.3673
1. 3884 1.4069 1.4213 1.4338 Core Height (ft)

= (Node -

1)
  • 0.2 15 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 7 W(Z)

AS A FUNCTION OF CORE HEIGHT (11,000 MWD/MTU) 1.650 1.600 1.550 1.500 1.450 N 1.400 1.350 1.300 1.250 1.200 1.150 1.100 1.050 1.000 iý 7

/

T-I I I

I hi~7'~

I I

r4z1/I I-0 1

2 3

4 5

6 7

8 9

10 11 12 BOTTOM CORE HEIGHT (FEET)

Axial Node 58 -

61 57 56 55 54 53 52 51 50 49 48 47 46 45 w(Z) 1.4639 1.4579 1.4415 1.4274 1.4183 1.4014 1.3796 1.3560 1.3297 1.3013 1.2770 1.2644 1.2558 Axial Node 44 43 42 41 40 39 38 37 36 35 34 33 32 31 w(Z) 1.2523 1.2517 1.2459 1.2383 1.2283 1.2181

1. 2083 1.1966 1.1909 1.1851 1.1757 1.1646 1.1515 1.1370 Axial Node 30 29 28 27, 26 25 24 23 22 21 20 19 18 17 w(Z) 1.1285 1.1292 1.1343
1. 1380 1.1409 1.1437 1.1460 1.1474 1.1486 1.1524 1.1566 1.1599 1.1627 1.1646 Axial Node 16 15 14 13 12 11.

10 9

8 7

6 5

1 - 4 TOP w(Z) 1.1711 1.1844 1.2014 1.2176 1.2338 1.2496 1.2651 1.2807 1.2956 1.3085 1.3181 1.3259 Core Height (ft)

= (Node -

1)
  • 0.2 16 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 8 W(Z)

AS A FUNCTION OF CORE HEIGHT (20,000 MWD/MTU) 1.650 1.600 1.550 1.500 1.450 1.400 1.350 1.300 1.250 1.200 1.150 1.100 1.050 1.000 I

I I i M

1.

i_

/_

_X 0

1 2

3 4

5 6

7 8

9 10 11 12 BOTTOM CORE HEIGHT (FEET)

Axial Node W (Z) 58 -

61 57 1.3907 56 1.3903 55 1.3811 54 1.3673 53 1.3519 52 1.3342 51 1.3137 50 1.2919 49 1.2669 48 1.2450 47 1.2367 46 1.2335 45 1.2268 Axial Node 44 43 42 41 40 39 38 37 36 35 34 33 32 31 w(Z) 1.2188 1.2170 1.2238 1.2304 1.2374 1.2436 1.2477 1.2516 1.2526 1.2504 1.2454 1.2376 1.2273 1.2138 Axial Node 30 29 28 27 26 25 24 23 22 21 20 19 18 17 w(Z) 1.2023 1.1988 1.2002 1.2007 1.1992 1.1972 1.1942 1.1895 1.1847 1.1808 1.1769 1.1722 1.1671 1.1659 Axial Node 16 15 14 13 12 11 10 9

8 7

6 5

1 -

4 TOP w (Z) 1.1760 1.1940 1.2094 1.2252 1.2406 1.2556 1.2702 1.2841 1.2969 1.3079 1.3161 1.3225 Core Height (ft)

=

(Node -

1)
  • 0.2 17 ERX-09-001, Rev.

0

COLR for CPNPP Unit 2 Cycle 12 FIGURE 9 AXIAL FLUX DIFFERENCE LIMITS AS A FUNCTION OF RATED THERMAL POWER W.

0 E

100 S(-15,100) 90 UNACCEPTABLE OPERATION 80 ACCEPTAI OPERATI 70

-j~i1------

60 F

1 -

0, 0 60 ll--4 30 (3,0-----------------------

30 711 10-.-.----------------

1

-t 0

-40

-30

-20

-10 0

10 20 30 40 AXIAL FLUX DIFFERENCE

(%)

18 ERX-09-001, Rev.

0