Rancho Seco Final Status Survey Summary Report, September 5, 2008 Spent Fuel Pool South Wall, (+) 0' El. to (+) 40' El.

Survey Unit F8120002 Prepared By:

Cý.

C/--

Date:

9/6/2-CrJ9g FSS Engineer.

.Reviewed By.:

D'*

ate:

%kh' tos Lead FSS Engineer Approved By:

7 Date:______

Dismantlement Superintendent, Radiological

FINAL STATUS SURVEY

SUMMARY

REPORT Survey Unit:

F8120002, Spent Fuel Pool South Wall, (+) 0' El. to (+) 40' El.

Survey Unit

Description:

Operating History: The reinforced concrete structure contained the spent fuel pool and supporting systems. The building contained three main elevations including the pool.

Residual radioactive material was known to be present on all levels of the interior of the building. Operating records and the HSA document several events with the potential for a release of radioactivity inside this structure. Three documented instances of contamination through the common fuel building/turbine building wall were noted.

Site Characterization: Direct measurements were made of each of the interior elevation surfaces as well as the exterior surfaces of the structure. These measurements confirmed the presence of plant-derived radionuclides. Direct measurements on the pool elevation showed a mean gross activity level of 16,900,000 dpm/100 cm 2 and a maximum value of 200,000,000 dpm/100 cm 2. Direct measurements on the +40' elevation showed a mean gross activity level of 5,942 dpm/100 cm 2 and a maximum value of 19,357 dpm/100 cm 2.

Direct measurements on the building exterior showed a mean gross activity level of 1,408 dpm/100 cm 2 and a maximum value of 21,600 dpm/100 cm2. Based on the classification procedure (DSIP-0020) and levels of gross activity' reported, the interior of the spent fuel building was determined to be a Class 1, 2 area and the exterior was a Class 2, 3.

HSA Events: HSA Report pg. 63.

Survey Unit Design Information:

The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were determined using a random-start, fixed grid pattern and 137.68 m2 were scanned for 100% coverage. Samples of removable contamination were collected at each direct measurement location. The instrumentation used for the survey along with the MDC values are listed in Tables2-1 and 2-2 in Attachment 2.

Page 2 of 8 FSS Summary Report F8120002

Table 1. Survey Unit Design Parameters Survey Design Value Comment Parameter Survey Area:

Survey Unit:

Class:

SU Area (m2):

Evaluator:

DCGL (dpm/100 cm 2):

Area Factor:

Design DCGLemc (dpm/100 cm 2):

LBGR (dpm/100 cm 2):

Design Sigma (dpm/100 cm 2):

Type I Error:

Type II Error:

Predominant Nuclide:

Sample Area (m2):

Scan Area (m2):

Scan Coverage (%):

Zip:

Sign P:

Calculated Relative Shift:

Relative Shift Used:

N-Value:

Design N-Value + 20%:

Design Min Samples N:

Grid Spacing L:

F812 0002 1

137.68 D. Anderson 43,000 3.6 154,800 21,500 12,246 0.05 0.05 Cs-137 2.62 137.68 100%

1.645 1.645 0.955435 1:7 1.7 14 17 20 2.62 Spent Fuel Pool South Wall Structure Surface LTP Table 5-4 Gross Activity DCGL Class 1 Class 1 Default = 50% DCGL Class I Class 1 Uses 3.0 if Relative Shift is

>3 NUREG-1575 Table 5-5 Class I Class I Page 3 of 8 FSS Summary Report F8120002

Survey Results:

A total of 20 direct measurements were made in F8120002. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. The gamma activity ranged from < 977 dpm/100 cm 2 Co-60 and < 1,130 dpm/100 cm2 to 50,475 dpm/100 cm 2 Cs-137. Beta scan activity ranged from 2,399 to 40,311 dpmr/100 cm 2, based on a surveyor efficiency of 0.5 and no background subtracted. Samples for removable surface activity were all less than 10% of the DCGL as shown in Table 3. Removable surface activity samples were counted for alpha activity and none was detected at the MDC shown in Table 2-1 of Attachment 2.

Table 2. Direct Measurement Results Measurement ID Gross Activity (dpm/100 cm F8120002-CO001 BD 7,978 F8120002-CO002BD 2,614 F8120002-CO003BD 3,076 F8120002-CO004BD 3,066 F8120002-CO005BD 1,930 F8120002-CO006BD 1,795 F8120002-CO007BD 1,478 F8120002-COOOBBD 1,463 F8120002-CO009BD 1,650 F8120002-CO01OBD 1,629 F8120002-CO011 BD 1,701 F8120002-CO012BD 1,867 F8120002-CO013BD 2,646 F8120002-CO014BD 2,635 F8120002-CO015BD 3,356 F8120002-CO016BD 1,727 F8120002-CO017BD 3,486 F8120002-CO018BD 2,371 F8120002-CO019BD 1,883 F8120002-CO02OBD 2,381 Mean:

2,537 Median:

2,150 Standard Deviation:

1,430 Range:

1,463 - 7,978 Page 4 of 8 FSS Summary Report F8120002

Table 3. Removable Surface Activity Results Measurement ID Surface Beta Activity (dpm/100 cm2) i F8120002C0001SM F8120002C0002SM F8120002C0003SM F8120002C0004SM F8120002C0005SM F8120002C0006SM F8120002C0007SM F8120002CO008SM F8120002C0009SM F8120002C0010SM F8120002C001 1 SM F8120002C0012SM F8120002C0013SM F8120002C0014SM F8120002C0015SM F8120002C0016SM F8120002C0017SM F8120002C0018SM F8120002C0019SM F8120002C0020SM Mean:

Median:

Standard Deviation:

Range:

8.09 9.38 5.51 21.01 2.93 0.34

-3.53

.-2.24 1.64

-2.24

-2.24

-0.95

-4.82

-2.24

-2.24 0.34 0.34

-0.95 4.22

-0.95 1.57

-0.3 5.93

-4.82 to 21.01 Page 5 of 8 FSS Summary Report F8120002

Survey Unit Data Assessment:

The survey design required 20 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.

Page 6 of 8 FSS Summary Report F8120002

Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm 2):

N/A Ambient Background Used (dpm/100 cm 2):

N/A Average Ambient BKG = 0 Actual Direct Measurements (N):

20 Median (dpm/100 cm 2):

2,150 Mean (dpm/100 cm 2):

.2,537 Direct Measurement Standard Deviation 1,430 (dpm/100 cm 2):

Total Standard Deviation (dpm/100 cm2):

1,430 Based on samples and backgrounds.

Maximum (dpm/100 cm 2):

7,978 Material Type:

N/A Background Subtract Not Applied Sign Test Final N Value:

20 S+ Value:

20 Critical Value:

14 Sufficient Samples Collected:

Yes Maximum Value < DCGL:

Yes Median Value < DCGL:

Yes Mean Value < DCGL:

Yes Maximum Value < DCGLemc:

Yes Class 1 Total Standard Deviation <= Sigma:

Yes Pass the Sign Test?

Yes Reject the Null Hypothesis?

Yes Does the Survey Unit Pass All Criteria?

Yes Page 7 of 8 FSS Summary Report F8120002

Survey Unit Investigations and Results:

No investigations were required for either direct or scan measurements and no investigation results are reported.

ALARA Statement:

As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.

Changes in Initial Survey Unit Assumptions:

The survey unit was designed as a Class 1 structure survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design. No potential areas of elevated activity were detected. Therefore the EMC criterion was met.

==

Conclusion:==

The FSS of this survey unit was properly designed as a Class 1 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP. No direct measurements exceeded the DCGL of 43,000 dpm/100 cm2 and none of the removable surface activity measurements exceeded 10% of the DCGL. No investigations were required.

The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.

It is concluded that survey unit F8120002 meets the release criteria of 10CFR20.1402.

Page 8 of 8 FSS Summary Report F8120002 Maps September 5, 2008 Survey Unit F8120002

-t 00 (C)

  • .1 C0 C>

oo Map F8120002-1, Fuel Storage Building Location at Rancho Seco site

h E

0.61m El. 40' 0' E.,40 LFl

.I E E 00CD CR 0)

J -

2-- --

I'

,,'I II I,

" I, II

',I

'/,

1-

-I e-tho

-O nn

1. 524 m

-i-701: m 2.26---

1372.....

I.

i -----------

.i..........

.......~- --------------

7..

e" X

P, p

....e n in g,.

7.01 mn 2.286 m 1.372 mn El. 0_0 10.668 m 0.0.

0.5' 1.0 1.5 2.0 Distance in Meters Map F8120002-2, Spent Fuel Pool South Wall Area Estimate: 137.68 sq. meters Page 3 of 9 Att. 1 Maps F8120002

I z.

-"-tll I_ _

I~

o BT-V 1:!l

, 1 C

~1~~

o

ý -..I I-IT I if-,

1ýý "-D T

nCi-=C 7 T--T*-T 7 -

0 5

10 15 20 25 30 35 40 45 50 55 0.0 0.5 1.0 1.5 2.0 DisWance in Motors Spent Fuel Pool South Wall Map F8120002-3, Spent Fuel Pool South Wall Random Start Location Page 4 of 9 Att. 1 Maps F8120002

in

= ________

Height in meters 11.06 m o...... -------

-91

- - - - - - - - - - - - - -- L - - - - - - - -

-0, 17 8.44 m 5.82 m -

3.2m 0.58 m hLIu U ) C

° ~o c*.c_..-


I ------ j ------------ I --------- :11ý

[ -------------- --------- : I---

- - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - -; F - - - - --- - --- ------------------------ -------

1 U

D 13BD ----

17 r"L513


r-


k ---------

I -----

I ----------------------

t,ý t


------------------- L


I ---


1-0 -----------------------

9 D

_7=J1 ý2B D

--7I7I7Iý


j,------- Z I D

7BD 513D


I --------- I


I 113D D

313D r- -T-i-T F7 E

0 E

04.

E r-ý E

(D CO o6 0.0 0,5 1,0 1.5 2.0 Distance in Meters Map F8120002-4, Spent Fuel Pool South Wall Beta Direct Measurements F8120002C0001BD to F8120002C0020BD 2.62 sq. meter grid spacing Page 5 of 9 Att. l Maps F8120002

Co o Coo

,.... C0020 Heig t......_

_i_ _'* - JjjI i

I...j..

1 I"

ItS 019 8.21 m 0*-

C0O4GS 0OO9GS O14sC019 5.72 m w--

C0003GS CO 08GS -- ---- Cool GS ---------

o m I/\\

//

\\

\\

3.24 mC0002GS

_______7C E

C02E 01 0.7 m

\\

/-

COOG 000

/O iG CO/ 6 I

o

-L*

-I* "--

Spent Fuel Pool South Wall GS GS i

1

/

/

/

/

0.0 0.5 1.0 1.5 2.0 Distance in Meters Map F8120002-5, Spent Fuel Pool South Wall ISOCS Gamma Scan Measurements F8120002C0001 GS to F8120002C0020GS 12.57 sq. meter field of view Page 6 of 9 Att. 1 Maps F8120002

rJQ (D

0

  • r1 00 I'Q C-)

Map F8120002-6, Spent Fuel Pool South Wall C)

ISOCS Gamma Scan Measurements IQa F8120002C0021GS to F8120002C0022JS 3.14 sq. meter field of view

LýJ ------------- -------

- - - - - - - - - - - - - - - ---:ý 4

-~

~ ~ ~ ~ ~,..

-~ ~

~

~

I ------------ ------

P,

'4 R

..... [-I:'

°..........

El' X,,*:

coo~

23GS -----------

25GS COO27GS r

r-------

-T--

1 CO2GS Spent Fuel Pool South Wall 0.0 0.5 1.0 1.5 2.0 Distance in Meters Map F8120002-7, Spent Fuel Pool South Wall ISOCS Gamma Scan Measurements F8120002C0023GS to F8120002C0027GS 3.14 sq. meter field of view Page 8 of 9 Att. I Maps F8120002

I HI*

_H

_ L 48 7

H__

I-----

------- : F -------------

D

,i46B S 1--

- -78r CO001Js CO002JS Spent Fuel Pool South Wall CO003JS 0.0 0.5 1,0 1.5 2.0 Distance in Meters Map F8120002-8, Spent Fuel Pool South Wall Beta Scan Measurements F8120002C0013BS to F8120002C0030BS and F8120002C0142BS to F8120002C0147BS Juncture Scan Measurements F8120002C0001JS to F8120002C0007JS Page 9 of 9 Att. 1 Maps F8120002 Instrumentation September 5, 2008 Survey Unit F8120002

Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.

Model; Serial No.

(dpm/100 cm2 )

(dpm/100 cm2 )

M2350; 203486 43-68B; 161400 433 1,033 M2350; 175834 43-116-1B; 190642 491 739 Tennelec; 0401171 N/A 5.88 dpm a, 11.71 dpm~

N/

MDC Concrete-1,130 dpm/100 cm2 Cs-137, Concrete - 977 dpm/100 cm2 Co-60 Table 2-2. Investigation Criteria and DCGL Value Parameter (dpm/100 cm 2)

Investigation Criteria - Direct 154,800 Investigation Criteria-Scan 63,300 Cs-137 (ISOCS average activity - 12.6 20,000 Co60 sq. meter field of view)

Investigation Criteria - Scan 180,000 Cs-137 (ISOCS average activity - 3.1 60,000 Co-60 sq. meter field of view)

DCGLw 43,000 DCGLEMC 154,800 Page 2 of 2 Att. 2 Instrumentation F8120002 Investigation September 5, 2008 Survey Unit F8120002 (none required)

Data Assessment September 5, 2008 Survey Unit F8120002

CD C)

C)

F8120002 Gross Activity Sample Results Quantile Plot DCGL = 43000 dpm/1 00cm2 I

4-9,000 8,000 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0

2150 0

20 40 60 Percentile 80 100 Direct Measurements (dpm/1O00cm2) -m edian -

- 75th Percentile.

50th Percentile

(IQ CD 0

rt CA 00 C)

C) t-F81 20002 Gross Activity Sample Results Scatter Plot DCGL = 43000 dpmi00icm=

E E

CL

  • 0 10000 8000 6000 4000 2000 0

-2000

-4000 00 0

0 0

-M

"..'1-M -

M T

in i

w!

w 4i 0

o o

o o

0 0

0 0

0

" 1" "1 I= "1

-1

=1 I

"I = I

-1 r

-t 7

l

  • 1 -

6827 2537

-1754 a

0 a

0 a

a a

a C) 0 0

C) a O

  • O mm O dO tmo ot om ca tOO mm to to mm O V-mt W

W f0t M

0 0

U U

U U

U U. U U U U U U U U U U U U U U Measurement Locations o

Gross Activity ---

Average -

"+3St~ev" --

"-3$tDev" kO................0 r.........r r.......r.........r rr.............................r r

I.....

~0 (D~

0n CD~

F8120002 Gross Activity Frequency Plot DCGL = 43000 dpm/1 OOcm 2 10 9

U-Ii 8

7 6

5 4

3 2

1 0

N-Cl (N

I,--

0O l--

roll 00d 00 Bins - Upper End Value (dpm/1 00cm2)