Final Status Survey Summary Report for February 24, 2009, Trench 1 Surface, Survey Unit F8100052
ML090900775
Person / Time
Site: Rancho Seco
(DPR-054)
Issue date: 02/24/2009
From: Frank G
Sacramento Municipal Utility District (SMUD)
To:
NRC/FSME
Shared Package
ML090830613 List: ... further results
References
DPG 09-097
Download: ML090900775 (18)


Text

Rancho Seco Final Status Survey Summary Report February 24, 2009 Trench I Surface Survey Unit F8100052 Prepared By: "..£__________te:__

FSS Engineer Reviewed By:

Date:

-0 Lead FSS Engineer Approved By:

"7 Date:_______

Dismantlement S rintendent, Radiological

FINAL STATUS SURVEY

SUMMARY

REPORT Survey Unit:

F8100052, Trench 1 Surface Survey Unit

Description:

Operating History: The area surrounded the tanks used to store radioactive liquids. This area was used for the storage of radioactive material. Operating records and the HSA document several events with the potential for a release of radioactivity associated with this survey area. The HSA documented the storage of radioactive material within the area that may have had the potential to contaminate the area.

Records of soil samples taken near the BWST showed soil contamination levels as high as 230 pCi/g prior to remediation.

Site Characterization: Soil samples were collected and analyzed for the presence of plant-derived radionuclides. Cs-137 was the primary nuclide of plant origin detected with a mean activity level of 379 pCi/g and a maximum value of 1,040 pCi/g. Based on the classification procedure (DSIP-0020) and levels of Cs-137 reported, the area was determined to be a Class I land area.

Survey Unit Design Information:

The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were determined using a random-start, fixed grid pattern and 660 m2 were scanned for approximately 100% coverage. Soil samples were collected at each direct measurement location and analyzed by HPGe detector. The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.

Page 2 of 8 FSS Summary Report F8100052

Table 1. Survey Unit Design Parameters Survey Design Parameter Value Comment Survey Area:

F810 Trench 1 Surface Survey Unit:

0052 Open Land Area Class:

1 LTP Table 5-4 SU Area (m2):

660 Evaluator:

G. Frank DCGL Cs137 surrogate (pCi/g):

51.2 Area Factor:

1.5 Class 1 Design DCGLemc (pCi/g):

79 Class 1 LBGR (pCi/g):

25.6 Default = 50% DCGL Design Sigma (pCi/g):

0.1 DTBD-06-001, Table 5-4D Type I Error:

0.05 Type II Error:

0.05 Nuclide:

Cs137 Sample Area (m2):

38.8 Class I Total Area Scanned (M2):

660 Scan Coverage (%):

100%

Class 1 Zl., :

1.645 Z*_P :

.1.645 Sign P:

0.99865 Calculated Relative Shift:

256 Relative Shift Used:

3 Uses 3.0 if Rel Shift >3 N-Value:

11 Design N-Value + 20%:

14 NUREG-1575 Table 5-5 Grid Spacing L:

6.9 Class I Page 3 of 8 FSS Summary Report F8100052

Survey Results:

A total of 38 direct measurements were made in F8100052. The results including mean, median, standard deviation and range are shown in Table 2. All of the direct measurements were less than the DCGL. ISOCS measurements resulted in no Co-60 activity greater than the MDA from Attachment 2, Table 2-1 the range of Co-60 is 0.168 to 0.277 pCi/g. Particle scans of the entire survey area were performed using a 2350-1 w/

44-10 with no readings above the investigation criteria in Attachment 2, Table 2-2 the range is 3201 to 4751 cpm. None of the scan measurements indicated areas of elevated activity.

Table 2. Direct Measurement Results (all activity values in pCi/g)

T Measurement ID Mean:

Median:

Standard Deviation:

Range:

F8100052AOOO1GS 2.21E-01 2.87E-01 1.59E-01 F8100052A0002GS 4.39E-01

< 4.39E-01 F8100052A0003GS 4.01E-01

< 4.01E-01 F8100052A0004GS 4.17E-01

< 4.17E-01 F8100052A0005GS 4.09E-01

< 4.09E-01 F8100052A0006GS 4.05E-01

< 4.05E-01 F8100052A0007GS 2.04E-01 4.01E-01 1.68E-01 F8100052A0008GS 2.40E-01 6.71E-01 2.17E-01 F8100052A0009GS 4.39E-01

< 4.39E-01 F8100052AOOOGS 3.90E-01

< 3.90E-01 F8100052AOO11GS 2.64E-01 3.91E-01 1.92E-01 F8100052A0012GS 2.20E-0 1 3.09E-0 1 1.62E-01 F8100052S0013GS 1.94E-01 3.18E-01 1.51E-01 F8100052S0014GS 4.68E-01

< 4.68E-01 F8100052S0015GS 2.07E-01 4.79E-01 1.78E-01 F8100052S0016GS 2.19E-01 4.75E-01 1.82E-01 F8100052S0017GS 2.1OE-01 2.82E-01 1.53E-01 F8100052S0018GS 1.97E-01

< 1.97E-01 1.25E-01 F8100052S0019GS 2.03E-01 6.45E-01 1.98E-01 F8100052S0020GS 4.18E-01

< 4.18E-01 F8100052S0021GS 2.15E-01 4.81E-01 1.81E-01 F8100052S0022GS 4.64E-01

< 4.64E-01 F8100052S0023GS 3.40E-01

< 3.40E-01 F8100052S0024GS 2.91E-01

< 2.91E-01 F8100052S0025GS 2.06E-01 4.13E-01 1.68E-01 Page 4 of 8 FSS Summary Report F8100052

F8100052S0026GS 3.70E-O1

< 3.70E-01 F8100052S0027GS 1.83E-01 2.59E-01 1.37E-01 F8100052S0028GS 3.70E-01

< 3.70E-01 F8100052S0029GS 3.40E-01

< 3.40E-01 F8100052S0030GS 3.92E-01

< 3.92E-01 F8100052S0031GS 3.97E-01

< 3.97E-01 F8100052S0032GS 1.95E-01 2.59E-01 1.43E-01 F8100052S0033GS 1.86E-01 2.97E-0 1 1.44E-0 1 F8100052S0034GS 1.60E-01 3.11E-01 1.36E-01 F8100052S0035GS 3.57E-01

< 3.57E-01 F8100052S0036GS 3.70E-01

< 3.70E-01 F8100052S0037GS 3.66E-01

< 3.66E-01 F8100052A0038GS 3.92E-01

< 3.92E-01 Page 5 of 8 FSS Summary Report F8100052

Survey Unit Data Assessment:

The survey design required 3 8 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 3. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.

.Page 6 of 8 FSS Summary Report F8100052

Table 3. Data Assessment Results Survey Results Parameter Value Comment Actual Direct Measurements (N):

38 Median (pCi/g):

3.91E-01 Mean (pci/g):

3.87E-01 Standard Deviation (pCi/g):

9.37E-02 Maximum (pCi/g):

6.71E-01 Sign Test Final N Value:

38 S+ Value:

38 Critical Value:

24 Sufficient Samples Collected:

Yes Maximum Value < DCGL:

Yes Median Value < DCGL:

Yes Mean Value < DCGL:

Yes Maximum Value < DCGLemc:

Yes Class 1 Standard Deviation <= Sigma:

Yes Pass the Sign Test?

Yes Reject the Null Hypothesis?

Yes The survey unit passes all conditions?

Yes Page 7 of 8 FSS Summary Report F8100052

Survey Unit Investigations and Results:

No investigations were required for either direct or scan measurements and no investigation results are reported.

ALARA Statement:

As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL, the ALARA criterion has been met.

Changes in Initial Survey Unit Assumptions:

The survey unit was designed as a Class 1 land survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design. No potential areas of elevated activity were detected. Therefore the EMC criterion was met.

==

Conclusion:==

The FSS of this survey unit was properly designed as a Class 1 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP, All of the direct measurements were less than the DCGL. No investigations were required.

The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.

It is concluded that survey unit F8100052 meets the release criteria of 10CFR20.1402, Page 8 of 8 FSS Summary Report F8100052 Maps February 24, 2009 Survey Unit F8100052

0 Trench 1 East Portion - Surface Scan w/44-10 for Discrete Particles

/

/

~0 4-

_0 0

Cl)

Soil I-T LO R-T 1414 1 CZ? 14 1 LIO* I qlcor I I,-

"Cr

-q-]U? I',

',n1 UI) r4n 0

= Gamma Background Asphalt 1061 091

~- ~JC~~

U

(

f

-0 O

- ~ -

-O -D 1-0

-~ MM 10

  • 1 1

08H f i l 1 It 00 C)

C>

tQ t

Concrete Gutter Edge F8100052-Mi

0 Trench 1 Eastern Portion ISOCS Scans cd~

-o

~0

_0 0:

~0 4-

-TI 00 IC)

Concrete Gutter Edge Measurements are center to center, unless noted by an arrow F8100052-M2 Instrumentation February 24, 2009 Survey Unit F8100052

Table 2-1. Survey Unit Instrumentation Detector Detector Serial Instrument Model MDC No.

No.

Soil - 0.468 pCi/g Cs-137 ISOCS N/A 2983947 Soil - 0.269 pCi/g Co-60 Asphalt- 0.439 pCi/g Cs-137 Asphalt - 0.277 pCi/g Co-60 2350-1 44-10 211672 5 pCi/g 2350-1 44-10 256101 5 pCi/g Table 2-2. Investigation Criteria and DCGL Instrument Parameter Value Soil - 51.2 pCi/g Cs-137 Soil - 12.6 pCi/g Co-60 ISOCS Investigation Criteria - Scan Sphl -51.2 pCi/g Cs-60 Asphalt - 51.2 pCi/g Cs-13 7 Asphalt - 12.6 pCi/g 2350-1 44-10 Particle Scan 8850 cpm All DCGLw 51.2 Cs-137 12.6 Co-60 Design DCGLEMC from Table 1 of FSS All DCGLEMC Summary Report or from DQA Evaluation Summary Page 2 of 2 Att. 2 Instrumentation F8100052 Investigation February 24, 2009 Survey Unit F8100052 (none required)

Data Assessment February 24, 2009 Survey Unit F8100052

0 It~

00 C:)

F8100052 Quantile Plot Cs137 DCGL = 51.2 pCi/g U

a.

U 0.800 0.700 0.600 0.500 0.400 0.300 0.200 0.100 0.000 0.391 0

.20 40 60 Percentile 80 100 I.

Activity -

Median -

- - 75th Percentile - - - - 50th Percentile

0D 0,

F~ 00052 Scatter Plot CJ2 F8 100052 Scatter Plot Cs 37.£CGL = 51.2 pCi/a 8.00E-01 7.00E-01

-~ ~ -.

0,668 6.00E-01 s 5.00E-01 000000 0

0 0

0 0

0 0

0 2.00E 4010 4 0

0 0

0 0

0 1.0E-0I-0.106 0

c < t. o W 0

to to 0 0o to 0 to 0 0to 0

40 to0 0 W 0 0 00 0 to to Measurement Locations

[

Activity -

Average -

"+3StDev" -

"-3StDev ti 00 C)

C)

C,,,

4r-C/2 00 C/2

(-h1 k)j i

F8100052 Frequency Plot Cs1 37 DCGL = 51.2 pCi/g 21 20-19 18 S17 c

16 ai) 15-14 a)13-12-if_ 12 C

1 1 o

10 4:

90

~8-7-

c)6-Q 5-0 4 3-2-

1-0-

(N N

N N-5 N2 (y

N Bins - Upper End Value (pCi/g)