17 NRC LIMERICK INITIAL EXAMINA TlON 10/2008 Limerick Generating Station Job Performance Measure Prepare a Partial Procedure JPM Number: RO A I - I Revision Number: 0 Date:
I I
Developed By:
Validated By:
Review By:
Approved By:
Tomlinson Author Monahan Facility Representative Haaqensen Examiner Caruso Chief Examiner 9/24/08 Date 1 011 108 Date 9/24/08 Date 9/25/08 Date RO ADMIN JPM Al-1.doc Page 1 of 7
I NRC LIMERICK
~NITIAL EXAMINATION 70/2008 171 ADMIN JPM #AI-.?
JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
1
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
Task description and number, JPM description and number are identified.
Knowledge and Abilities (WA) references are included.
Performance location specified. (implant, control room, or simulator)
Initial setup conditions are identified.
Initiating and terminating cues are properly identified.
Task standards identified and verified by Examiner review.
Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date Pilot test the JPM:
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
I O. If the JPM cannot be performed as written with proper responses,
page.
RO ADMlN JPM Al-l.doc Page 2 of 8
NRC LIMERICK /NlTlAL EXAMINATION 10/2008 ADMIN JPM # AI-7 REVISION RECORD (Summary):
JPM Setup Instructions:
- 1. Provide a copy of ST-6-043-200-1 including Attachment 1 on yellow paper and a copy of AD-LG-101-1002 on white paper.
- 2. Applicant is given instruction to prepare a partial ST for post maintenance testing (PMT) of HV-048-1 F020, Outboard Sample PClV following limit switch replacement.
TASK STANDARD: The applicant should prepare the partial ST in accordance with plant procedures, AD-LG-101-1002. Comments on the front should be Partial ST prepared for PMT HV-43-1 FO20 per C099590301, prepared by: name, initials, date and signature.
Critical that PARTIAL is written and comments made. Signature, date, initials and name are not critical to task. They may also write SQR By and leave blank for the Station Qualified reviewer, but it is not required, as the SQR will. In the body of the test, the applicant should line out, initial, and date the following items for the valve not being tested, FOI9: pg. 2 first item under purpose, pg.6 step 4.3.2 first item, Attachment 1 Upper row (critical), pg.ll first item, and pg. 12 Upper row (critical).
TASK CONDITIONS:
Maintenance on HV-048-1 FO20 is complete per work order C099590301.
0 A partial ST for PMT on this valve needs to be completed.
Prepare partial of ST-6-043-200-1 INITIATING CUE:
The Control Room Supervisor directs you to prepare a partial ST to facilitate the PMT on valve HV-048-1 F020 following maintenance per work order C099590301. Prepare a partial ST using ST-6-043-200-1.
Information For Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
RO ADMlN JPM Al-l.doc Page 3 of 8
NRC LIMERICK INlTiAL EXAMINATION 7 0/2008 Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
RO ADMlN JPM AI-I.doc Page 4 of 8
NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMlN JPM # A I - ?
Operators Name:
Job
Title:
SRO 0
STA 0
Title:
Perform Reactor Coolant Leakage Surveillance JPM Number: RO AI-I Revision Number: 0 KIA Number and Importance: Generic 2.2.1 1 Knowledge of the Process for Controlling Temp Changes (CFR: 41. I O / 43.3 / 45.13) IMPORTANCE RO 2.5 SRO 3.4 Suggested Testing Environment: Classroom - Group Actual Testing Environment: Table-top - Group Testing Method: Simulate Faulted: No Alternate Path: No Time Critical: No Estimated Time to Complete:
Actual Time Used:-I 5-minutes
References:
ST-6-043-200-1 ; AD-LG-1 01 -1 002 EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0 No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
Eva1 ua tors Name :
(Print)
RO ADMlN JPM Al-1.doc Page 5 of 8
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMIN JPM # AI-1 Evaluators Signature:
Date:
==
Description:==
Maintenance on HV-048-1 FO20 is complete per C099590301. A partial ST of ST-6-043-200-1 for PMT needs to be completed. The RO needs to prepare partial of ST-6-043-200-1 to facilitate the PMT following maintenance per work order C099590301.
JPM is designed to test the ability to create a temporary change to a procedure. The candidate will be provided the entire procedure and the work order outlining the maintenance completed on the equipment. The partial ST needs to fulfill the requirement for the PMT.
Candidate should identify at the top of the procedure that this is a PARTIAL ST prepared for PbIT HV-43-1 F020 per C099590301. Candidate should line out, initial and date the upper row on and the upper row on pg. 12 of the ST.
RO ADMlN JPM Al-l.doc Page 6 of 8
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMlN JPM #AI-1 NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time
~~
ELEMENT
~~
-~
UNSAT STANDARD Com rri e n t Number I. Hand the applicant:
JPM cue sheet Review the handouts Examiner Cue: If asked for a copy of the C0995903 work order, inform the applicant that the work order has been evaluated by the Work Center Supervisor.
- 2. Write PARTIAL at the top of the cover sheet. of ST-6-043-200-1 PARTIAL written at the top of the cover page. See answer key.
- 3. Write comments on the cover page to include See answer key Comment written.
3a. Partial ST prepare for PMT HV 1 F020 per C099590301 3b. Prepared By: name, initials, date, signature Comment written.
- 4. Line out, initial and date the following procedure steps See answer key I
Line out, initial and date 4a. Pg. 2 first item under purpose:
4b. Pg. 6 step 4.3.2 first item
- 4c. Attachment 1 upper row Line out, initial and date Line out, initial and date 4d. Pg. 11 first item Line out, initial and date I
NRC LIMERICK INITIAL EXAMINA TlON 10/2008 ADMlN JPM #AI-,!
HANDOUT PAGE TASK CONDITIONS:
0 Maintenance on HV-048-1 FOZO is complete per C099590301.
A partial ST for PMT needs to be completed.
0 Prepare partial of ST-6-043-200-1 INITIATING CUE:
0 The Control Room Supervisor directs you to prepare a partial ST of ST-6-043-200-1 to facilitate the PMT on valve HV-048-1 FOZO following maintenance per work order C099590301.
NRC LIMERICK INITIAL EXAMINATION 7 012008
- I Limerick Generating Station Job Performance Measure Evaluate Jet Pump Operability JPM Number: RO AI-2 Revision Number: 1 Date:
I I
Developed By: Tomlinson 9/24/08 Author Date Validated By:
Monahan 10/1/08 Tech n i ca I Re view e r Date Review By:
Haaclensen 9/25/08 Examiner Date Approved By: Caruso 9/26/08 Chief Examiner Date RO A DMlN JPM A 1-2. doc Page 1 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
A DMlN RO JPM #A 1-2 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
- 1. Task description and number, JPM description and number are identified.
- 2. Knowledge and Abilities (WA) references are included.
- 3. Performance location specified. (in-plant, control room, or simulator)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
- 10. If the JPM cannot be performed as written with proper responses,
E RO A DMlN JPM A 1-2. doc Page 2 of 8
NRC LIMERICK INITIAL EXAMlNA TlON 10/2008 I
ADMlN RO JPM #A1-2 REVISION RECORD (Summary):
- 1. This JPM was revised from the original bank version by changing the OMS screen shot data. The total core flow test in step 4.3.3.4 is now SAT instead of UNSAT - on the original version of the JPM. The final outcome of the surveillance is still UNSAT.
JPM Setup Instructions:
- 1. Provide OMS Screen Shots (2 pages), ON-I00 and yellow copy of a ST-6-043-320-1, Daily Jet Pump Operability Verification for Two Recirculation Loop Operation (file password is gb3v) not filled in.
- 2. Provide calculator to applicant
- 3. Applicant is given instruction to perform ST-6-043-320-1, enter the data and report res u I ts.
TASK STANDARD: The candidate should report the test is unsatisfactory due to failing on A loop drive flow high and A loop jet pumps flow low.
TASK CONDITIONS:
Unit I plant conditions are as follows:
Todays date is 6/9/08 0 An unexpected drop in reactor power occurred 0 An unexplained rise in core flow occurred 0 ON-100, FAILURE OF A JET PUMP was entered INITIATING CUE:
0 The Control Room Supervisor directs you to perform ST-6-043-320-1 (Daily Verification of Jet Pump Operability for Two Recirculation Loop Operation) complete the data and report the results.
Information for Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
RO A DMlN JPM A 1-2. doc Page 3 of 8
NRC LIMERICK INITIAL EXAMlNATlON 70/2008 ADMIN RO JPM #A 1-2 Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
Operators Name:
Job
Title:
SRO 0
STA 0
Title:
Evaluate Jet pump Operability JPM Number: RO A1-2 Revision Number: 0 KIA Number and Importance:
Generic 2.1.I9 ability to use Plant computers to Evaluate System or Component Status (CFR: 41.10 / 45.12) IMPORTANCE RO 3.9 Suggested Testing Environment: Classroom Actual Testing Environment:
Testing Method: Simulate Faulted: Yes Alternate Path: No Time Critical: No Estimated Time to Complete:
Actual Time Used:-I 5-minutes
References:
ST-6-043-320-1 EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0
No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
RO A DMlN JPM A 1-2. doc Page 4 of 8
- A
~~
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMIN RO JPM #A1-2 Note: Any grade of UNSAT requires a comment.
Evaluators Name:
(Print)
Eva1 uato rs Signature :
Date:
RO ADMIN JPM A1-2.doc Page 5 of 8
I NRC LIMERICK INITIAL EXAMlNAT/ON 70/2008 I
ADMIN RO JPM #AI -2 NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT
- 1. Hand the applicant:
PMS computer screen shots 0
Calculator JPM cue sheet
- 2. STEP 4.3.1.3 Determine if Loop A flow is within 10% of the loop flow values on the established pump speed-loop flow characteristic curve
- 3. Step 4.3.2.3 Determine if Loop B flow is within 10% of the loop flow values on the established pump speed-loop flow characteristics curve
- 4. Step 4.3.3.4 Determine if the value of total core flow is within 10% of the established Total Core Flow value derived from Recirc Loop Flow Measurements
- 5. Step 4.3.4.4 Determine if Loop A jet pump diffuser-to-lower plenum differential pressure is within 10% of the established patterns STANDARD Review the handouts Determines that loop A is NOT within the limits -
UNSAT.
Examiner cue: If asked for recirc pump flow from FR 1 R614 point 1, inform the applicant this is 47,146 gpm.
Determines that loop B is within the limits - SAT Examiner cue: If asked for recirc pump flow from FR 1R614 point 2, inform the applicant this is 40,642 gpm.
Determine that total core flow is within the limits - SAT.
Determine that some of the jet pumps on Loop A are NOT within the limits - UNSAT.
SAT -
Number 7
RO ADMlN JPM A1-2.doc Page 6 of 8
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
~
ELEMENT
- 6. Step 4.3.5.4 Determine if Loop B jet pump diffuser-to-lower plenum differential pressure is within 10% of the established patterns
- 7. Verify at least two of the step combinations in the surveillance are satisfactory:
drive flow) 4.3.1.3 and 4.3.2.3 (Pump speed vs.
4.3.3.4 (Total loop flow vs. total core flow)
CUE: (You may stop here. You have reached the termination criteria for this JPM)
JPM Stop Time STANDARD Determine that all of the jet pumps on Loop "B" are within the limits - SAT Determine that two of three areas are UNSAT and the overall ST results are UNSAT UNSAT + SAT = UNSAT SAT UNSAT + SAT = UNSAT 2 UNSAT + 1 SAT = UNSAT Report the unsatisfactory results - The A jet pumps have failed the surveillance test.
UNSAT --=
Comment Number RO ADMlN JPM A1-2.doc Page 7 of 8
I NRC LlMERlCK INlTlAL EXAMlNATlON 10/2008 I
ADMIN RO JPM #A7-2 HANDOUT PAGE TASK CON D IT1 0 N S :
Unit 1 plant conditions are as follows:
Todays date is 6/9/08 An unexpected drop in reactor power occurred An unexplained rise in core flow occurred ON-100, FAILURE OF A JET PUMP was entered INITIATING CUE:
0 The Control Room Supervisor directs you to perform ST-6-043-320-1 (Daily Verification of Jet Pump Operability for Two Recirculation Loop Operation) for 00:15 on 6/10/08 complete the data and report the results.
Limerick Generating Station Job Performance Measure Perform Reactor Coolant Leakage Surveillance JPM Number: RO A2 Revision Number: 1 I
I Date:
Developed By: Haagensen Author Validated By:
Review By:
Approved By:
Facility Representative Hedigan Examiner Caruso Chief Examiner 1/24/2008 Date Date 9/25/08 Date 9/25/08 Date
JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM revalidate JPM using steps 8 through 11 below.
- 1. Task description and number, JPM description and number are identified.
- 2. Knowledge and Abilities (KIA) references are included.
- 3. Performance location specified. (in-plant, control room, or si m u I a to r)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
I O. If the JPM cannot be performed as written with proper responses,
Jeff Stevens questions 9/24/08:
- 1. What is the total capacity of the floor sump and the equipment sump? At what point would they be pumpea down (hi level alarm?). 1080 gallons capacity - DWEDT pumped automatically at 22.5 to 6.2 ft, DWFDT pumped between 21.5 and 6.2 ft.
- 2. If the sumps were pumped down between tech spec surveillance intervals, would this be logged on the surveillance comment sheet?
- 3. We are adding a source of IDENTIFIED LEAKAGE in the drywell (Rx head vent). How would this be documented in the surveillance test?
- 4. We are adding another leak in the equipment drain (DWEDT) tank -what are the likely sources for leakage into this sump?
RPV bottom head drain RPV head seal leakoff RPVVent Reactor Recirculation System pump seals RPV to drywell bellows seal drain
REVISION RECORD (Summary):
- 1. Modified original JPM to add in 1.5 gpm identified leakage from the RPV head vent and to exceed tech spec 3.4.3.2.f (> 2 gpm increase in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) instead of tech spec 3.4.3.2.b (> 5 gprn unidentified leakage).
JPM Setup Instructions:
- 1. Hand out the following materials 0
ST-6-1 07-596-2 Drywell Floor Drain SumplEquipment Drain Tank Surveillance Log lOPCON 1, 2, 3 - partially completed.
Techspecs Calculator TASK STANDARD: The applicant should determine that the floor drain average leak rate is X gpm and has exceeded the Tech Spec limit of 2.0 gpm increase over 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The applicant should determine that tech spec LCO 3.4.3.2.f has been exceeded (UNIDENTIFIED LEAKAGE has increased by more than 2 gpm over a 24-hour period.
TASK CONDITIONS:
The Unit 2 has been operating at 100% power for 5 days.
0 There is known IDENTIFIED LEAKAGE of 1.5 gpm coming from the Unit 2 head vent valve into the drywell.
All steps of ST-6-107-596-2 have been completed for days 1, 2 and part of day 3 for the weekly surveillance. These have been filled out on the attached data sheets.
The following readings were taken by the RO at 00:15 for the day 3 data sheet.
FI-61-215 = 2.3 gpm FI-61-235 = 21. I gpm FQRSH-61-212 point 3:
FQRSH-61-212 point 4:
Reading = 1000 gallons Reading = 950 gallons Min since last reset = 60 min Min since last reset = 45 min INITIATING CUE:
The Control Room Supervisor directs you as RO to complete ST-6-107-596-2 Drywell Floor Drain Sump/Equipment Drain Tank Surveillance Log /OPCON 1, 2, 3 at 00:15 for day 3 using the above data.
Information For Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
Operators Name:
Job
Title:
D NLO X RO D SRO D STA D SRO Cert JPM
Title:
Perform Reactor Coolant Leakage Surveillance JPM Number: RO A2 Revision Number: 0 KIA Number and Importance:
Generic 2.2.1 2 Knowledge of surveillance procedures. (CFR:
41. I O I45.13) IMPORTANCE RO 3.7 SRO 4.1 Suggested Testing Environment: Classroom - Group Actual Testing Environment:
Testing Method: Table-top Faulted: Yes Alternate Path: No Time Critical: No Estimated Time to Complete:
Actual Time Used:-I 5-minutes
References:
ST-6-107-596-2 EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
D Yes No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory Cl Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
Evaluators Name:
(Print)
Evaluators Signature:
Date:
==
Description:==
A reactor coolant leakage surveillance is completed and unidentified leakage is found to be within 5 gpm UNIDENTIFIED LEAKAGE but to exceed 2 gpm increase in INDENTIFIED LEAKAGE over a 24-hour period. Tech Spec LCO 3.4.3.2.f has been exceeded and action statement e applies (Identify the source of leakage within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Development Notes: Rev 1 - modify to address larger indentified leakage into the equipment sump and a leaking head vent (that has been classified as IDENTIFIED LEAKAGE) at 1.5 gpm into the drywell.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT
- 1. Hand the applicant:
ST-6-107-596-2 (partially completed)
JPM cue sheet with leakage 0
11 data
- 2. Enter the surveillance test data from the cue sheet for 00: 15 on the day 3 page of ST-6-107-596-2
- 3. Complete Table 1 for day 3.
- 4. Complete Table 2 for day 3.
STANDARD Review the handouts Data entered properly per answer key page.
Determine total leak rate is 23.4 gpm -which is SAT Determine unidentified leak rate is 2.5 gpm - which is SAT.
Determine that unidentified leak rate has increased by 2.4 gpm over the past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and mark step 4.2.7.1 as UNSAT.
Examiner Note: the block for the previous 00:15 reading was entered incorrectly.
The correct entry should have been 0.1 gpm instead of 1.2 gpm. The applicant should catch this error and correct the entry.
Fill in data from day 3 at 00:15 from handout sheet.
UNSAT --
Comment Number
I ELEMENT
- 5. Calculate values in Table 3 for day 3 at 00:15.
- 6. Determine applicable Tech Specs.
i JPM Stop Time STANDARD Floor sump average leak rate
= 2.5 gpm (this is UNIDENTIFIED leakage).
Equipment sump average leak rate = 21.11 gpm Total average leak rate =
23.61 gpm Determine UNIDENTIFIED leak rate is UNSAT because there was a 2 gpm increase in unidentified leakage over a 24-hour period.
Tech Spec LCO 3.4.3.2.f has been exceeded 2 gpm increase in UNIDENTIFIED LEAKAGE over a 24-hour period.
Tech Spec LCO 3.4.3.2.b (5 gpm UNIDENTIFIED LEAKAGE) has NOT been exceeded.
Tech Spec LCO 3.4.3.2.c (30 gpm TOTAL LEAKAGE) and 3.4.3.2.d (25 gpm averaged over any 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period) have NOT been exceeded.
Examiner note: If the applicant states that either Tech Spec 3.4.3.2.b, c or d havebeenexceeded,then the applicant fails this JPM.
SAT f
UNSAT 3
Corn in en t Number
HANDOUT PAGE TASK CONDITIONS:
0 The Unit 2 has been operating at 100% power for 5 days.
0 There is known IDENTIFIED LEAKAGE of I
.5 gpm coming from the Unit 2 head vent valve into the drywell.
0 All steps of ST-6-1 07-596-2 have been completed for days 1, 2 and part of day 3 for the weekly surveillance. These have been filled out on the attached data sheets.
0 The following readings were taken by the RO at 00:15 for the day 3 data sheet.
FI-61-215 = 2.3 gpm FI-61-235 = 21.I gpm FQRSH-61-212 point 3:
FQRSH-61-212 point 4:
Reading = 1000 gallons Reading = 950 gallons Min since last reset = 60 min Min since last reset = 45 min INITIATING CUE:
The Control Room Supervisor directs you as RO to complete ST-6-1 07-596-2 Drywell Floor Drain Sump/Equipment Drain Tank Surveillance Log /OPCON 1, 2, 3 at 00:15 for day 3 using the above data.
NRC LIMERICK INITIAL EXAMINATION 7 0/20/2008
-1 Limerick Generating Station Job Performance Measure Determine Offgas Effluent Activity Release Rate JPM Number: RO A3 Revision Number: 0 Date:
I
/ 2008 Developed By: Tomlinson Author Validated By:
Monahan Facility Representative Review By:
Haagensen Examiner 1
Approved By: Caruso I
Chief Examiner 9/24/2008 Date 10/1/2008 Date 9/24/2008 Date 9/25/08 Date RO A DMlN JPM A3. doc Page 1 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMIN JPM #A3 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
~~
- 1. Task description and number, JPM description and number are identified.
- 2. Knowledge and Abilities (WA) references are included.
- 3. Performance location specified. (in-plant, control room, or simulator)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
2 Date
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
I O. If the JPM cannot be performed as written with proper responses,
~~
~
I NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMlN JPM #A3 REVISION RECORD (Summary):
JPM Setup Instructions:
- 1. Provide applicant copy of GP-5 STEADY STATE OPERATIONS
- 2. Provide calculator to applicant
- 3. Unit 1 is in OPCON I
- 4. RR-26-1 R601 A SJAE Discharge Rad Monitor reads 110mRem/hr
- 5. RR-26-1 R601 B SJAE Discharge Rad Monitor reads 131 mRem/hr
- 6. FR-69-*I5 (scfm) Point 2 Reads 35 scfm TASK STANDARD: The applicant should calculate the average pre-treatment release rate to be 4619 to 5105 (4862 +/- 5%)
RO A DMlN JPM A3. doc Page 3 of 10
NRC LIMERICK INITIAL EXAMINATION 10/2008
- I ADMlN JPM #A3 TASK CONDITIONS:
- 1. Unit 1 is in OPCON 1
- 2. RR-26-1 R601 A SJAE Discharge Rad Monitor reads 110mRemlhr
- 3. RR-26-1 R601 B SJAE Discharge Rad Monitor reads 13lmRemlhr
- 5. The following placard is mounted to the 10C600 panel:
U/1 OFFGAS SUMOFSIX j4J K A K B 1.18 1.13 -
10/6108 I DATE:
INITIATING CUE: The CRS has directed you to calculate the average offgas pre-treatment radioactivity release rate per GP-5, STEADY STATE OPERATIONS Information for Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
=
RO ADMlN JPM A3.doc Page 4 of 10
NRC LIMERICK INITIAL EXAMINATION 10/2008
-1 ADMlN JPM #A3 Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
i RO ADMlN JPM A3.doc Page 5 of 10
NRC LIMERICK INITIAL EXAMINATION 10/2008
-1 ADMlN JPM #A3 Operators Name:
Job
Title:
Title:
Authorize Reactor Maneuvering Shutdown Instructions Following a Rod Pattern Adjustment JPM Number: A3 Revision Number: 0 K/A Number and Importance: 2.3.1 1 Ability to Control Radiation Releases (CFR: 41.I 1 I 43.4 I
45.10)
IMPORTANCE RO 3.8 SRO 4.3 Suggested Testing Environment: Classroom - Group Actual Testing Environment:
Testing Method: Table-top Faulted:
Yes Alternate Path: No Time Critical: No Estimated Time to Complete:
15 Actual Time Used:
minutes
References:
EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes Cl No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
Evaluators Name:
(Print)
Eva1 ua tors Signature :
Page 6 of 10
I NRC LlMERlCK /NlTlAL EXAMINATION 7 0/2008 I
ADMIN JPM #A3
==
Description:==
Unit 1 is in OPCON 1. The SJAE rad monitors are reading 11 0 mRem/hr and 1311 mRem/hr respectively. Placard is posted at the 1 OC600 panel as follows:
UI1 OFFGAS SUMOFSIX 140 1.I8 1.13 K A K B DATE:
10/20/08 Cue is that a CRS has directed you to calculate the average pre-treatment radioactivity release rate per GP-5, STEADY STATE OPERATIONS.
Candidate should calculate the average release rate using the posted information and GP-5 step 3.1.19.
RO ADMlN JPM A3.doc Page 7 of 10
-1 NRC LIMERICK INITIAL EXAMINATION 10/2008 SAT -
NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
UNSAT Comment Number JPM Start Time ELEMENT
- 1. CALCULATE Off-gas release rates for the A AND B channels using the following equation:
RR = RL x F x K Where:
RR = Release Rate for A(B)
(pCi/second)
RL = Radiation Level of SJAE as indicated on RR-26-*R601 (mRem/hour)
F = Off-gas flow as indicated by FR-69-*I 5 (scfm),
Point 2 K = C Conversion Factor for A(B) data (posted on panel *OC600)
- 2. Channel A (Point 1)
RR =-
mRem/hour x -CFM x
-K-RR =
pCi/second
- 3. Channel B (Point 2)
RR =-
mRem/hour x -CFM x
-K-RR =
pCi/second STANDARD N/A Zalculate A channel release 4543 pCi/sec 2alculate 8 channel release
- 5181 pCi/sec 31 x 35 x 1.13 = 5181 ADMlN JPM #A3
I NRC LIMERICK INITIAL EXAMINA TlON 10/2008 I
ELEMENT
- 4.
CALCULATE the average of the A
&@ B channel values to obtain the average Off-gas pretreatment release rate as follows:
ARR = /RR A)
+ (RR "B")
2 Where:
ARR = Average Off-gas Pretreatment Release Rate (pCi/second)
RR "A' = Release Rate value for " A Channel (pCi/second)
RR "B" = Release Rate value for "B" Channel (pCi/second)
ARR =
) + (
1 ll 2
ARR =
pCi/second (CUE: You may stop here; you have met the termination criteria for this JPM.)
STANDARD Calculate the average release rate ARR= (4543 +5181)/2 = 4862 pCi/sec Acceptable band is 4619 to 5105 (4862 +/- 5%)
N/A SAT N/A ADMlN f
- A3 UNSAT Comment Number JPM Stop Time
NRC LIMERICK INITIAL EXAMINA TlON 10/2008
-1 ADMlN JPM #A3 HANDOUT PAGE TASK CONDITIONS:
- 1. Unit 1 is in OPCON 1
- 2. RR-26-1R601 A SJAE Discharge Rad Monitor reads IlOmRem/hr
- 3. RR-26-1 R601 6 SJAE Discharge Rad Monitor reads 131 mRem/hr
INITIATING CUE: The CRS directs you to determine the average offgas pre-treatment radioactivity release rate per GP-5, STEADY STATE OPERATIONS.
NRC LIMERICK INITIAL EXAMINATION 10/20/2008 I
Limerick Generating Station Job Performance Measure Authorize a Reactor Maneuvering Shutdown Instruction (RMSI)
Following a Rod Pattern Adjustment JPM Number: SRO AI-1 Revision Number: 1 Date:
10/1/2008 Developed By: Haagensen Author Validated By:
Monahan Facility Representative Review By:
Tomlinson Examiner Approved By: Caruso Chief Examiner 9/24/2008 Date 10/1/08 Date 9/24/20 0 8 Date 9/25/08 Date SRO ADMlN JPM A ?-?.doc Page 1 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008
.I ADMlN JPM #A I-1 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
7
- 1. Task description and number, JPM description and number are identified.
- 2. Knowledge and Abilities (KIA) references are included.
- 3. Performance location specified. (in-plant, control room, or si m u I a to r)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
2 Date -
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
IO. If the JPM cannot be performed as written with proper responses,
Review Questions and Comments:
- 1. Missing NF-LG-721-2001 Exhibit 6. This is referenced in the procedure that is handed out. Locate this procedure - check with Jeff Stevens.
- 2. Not clear how the CRS will review the RMSI. The handout procedure NF-LG-721-1005 lists the review steps 6.3.2 but these are for RE review, not SRO review.
- 3. Not clear what the pre-down power positions were. Need more information or another handout?
- 4. Talk to Jeff Stevens.
SRO ADMlN JPM Al-?.doc Page 2 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMIN JPM #AI-I REVISION RECORD (Summary):
JPM Setup Instructions:
I.
Hand out the following materials 0
P-I Core Map 0
Reactor Maneuvering Shutdown Instructions 0
NF-LG-721-1005 Reactor Maneuvering Shutdown Instructions Preparation Guideline I.
Changed setup so that only one rod (1 4-47) was out of position instead of 4 rods.
TASK STANDARD: The applicant should determine that the SRO should NOT authorize the Reactor Maneuvering Shutdown Instructions because there is a rod out of position from the P-I core map. Rod 14-47 is out of position.
TASK CONDITIONS:
- 1. A rod pattern adjustment has just been completed.
- 2. The Reactor Engineer has handed you a new Reactor Maneuvering Shutdown Instruction (RMSI). The RMSI has been prepared and verified on 1012012008 by qualified reactor engineers, Brian Haagensen and Joyce Tomlinson
- 3. The Reactor Engineer states that the 3D MONICORE PREDICTOR results have been independently verified using the checklist in Exhibit 6 of NF-LG-721-2001 to determine successful case execution.
INITIATING CUE: The Reactor Engineer requests that you authorize the new RMSI.
Information For Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
SRO ADMlN JPM A ?-?.doc Page 3 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008 7
A DMlN JPM #A I - ?
Operators Name:
Job
Title:
0 NLO 0
STA 0
Title:
Authorize Reactor Maneuvering Shutdown Instructions Following a Rod Pattern Adjustment JPM Number: AI-I Revision Number: 0 KIA Number and Importance:
- 2. I
.37 Knowledge of procedures, guidelines, or limitations associated with reactivity management. (CFR: 41.I
/ 43.6 / 45.6) IMPORTANCE SRO 4.6 Suggested Testing Environment:
Classroom Actual Testing Environment:
Testing Method: Simulate Faulted:
Yes Alternate Path: No Time Critical: No Estimated Time to Complete:
15 Actual Time Used:
minutes
References:
NF-LG-721-1005 EVALU AT10 N SUM MARY:
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0 No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
Eva I uato rs Name :
(Print)
Eva1 uators Signature :
Date:
SRO ADMlN JPM Al-l.doc Page 4 of 7
NRC LIMERICK INITIAL EXAMlNA TlON 7 0/2008 ADMlN JPM #A?-?
==
Description:==
A rod pattern adjustment has just been completed. The Reactor Engineer has brought the new Reactor Maneuvering Shutdown Instructions (RMSI) to the control room and requested that the Shift ManagerICRS authorize (or activate) the new instructions. There is one rod out of position (14-47) on the Instruction sheet. The applicant must compare the instruction sheet to the P I core map and determine that the SRO should not activate the sheet.
JPM is designed to test the ability to determine that a new RMSl rod insertion sheet has been submitted for SRO approval with an error. The candidate will be provided the RMSI package and a core map thal shows one of the rods in the RMSl listed to be inserted are already inserted The SRO signoffs are on the RMSl cover sheet and the rod sequence sheet. The candidate may be cued as to the locations to sign, as RES are usually asked and will show the SRO where to sign.
Must be provided with the scanned P-I showing the rod pattern Fill out NF-AB-721-1005 Page 7 with R. Potter in the Reactor Engineer signoff Fill out page 8 with RWM Sequence ID LGSIMSU2.0 RE/QNE R. Potter 2d Verifier A. Johnson Step 1
2 3
4 5
6 7
8 9
10 11 12 Rod ID 22-39 38-23 38-39 22-23 30-47 30-1 5 46-31 14-31 14-47 46-1 9 14-1 9 46-43 Target 00 00 00 00 00 00 00 00 00 00 00 00 This rod is out of position NA remaining blanks on rod sheet place NA in each column with a down arrow to bottom Page 3 enter LGSIMSU2.0 at step 53 at the bottom.
Cue is that a rod pattern exchange took place and the RE has provided the new RMSl for SRO approval signoff on page 1 and 2 Candidate should identify the step 9 rod is incorrect and already at 00 SRO ADMlN JPM A1-l.doc Page 5 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMlN JPM #A?-I NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT I
- 1. Review the 30 MONICORE PREDICTOR results generated in step 6.3.1 using the checklist in Exhibit 6 of NF-LG-721-2001 to determine successful case execution.
- 2. Confirm that the load line is less than the lower boundary of the instability exclusion region of the unit specific power/flow operating map.
~~~
- 3. Confirm all rods are at either their pre-down power positions or at position 00.
/I *4. Determine if the RMSl should be authorized for use.
STANDARD The case execution was successful as indicated by the initial conditions.
Determine the load line is less than the lower boundary of the instability exclusion regions of the power/flow operating map.
Identify that rod 14-47 is not at the correct pre-down power position and not at the 00 position.
Do NOT authorize the RMSl-do not sign the RMSI.
SAT UNSAT Comment 1
1 Number JPM Stop Time
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMlN JPM #AI-?
HANDOUT PAGE TASK CONDITIONS:
- 1. A rod pattern adjustment has just been completed.
- 2. The Reactor Engineer has handed you a new Reactor Maneuvering Shutdown Instruction (RMSI). The RMSI has been prepared and verified on IO12012008 by qualified reactor engineers, Brian Haagensen and Joyce Tomlinson
- 3. The Reactor Engineer states that the 3D MONICORE PREDICTOR results have been independently verified using the checklist in Exhibit 6 of NF-LG-721-2001 to determine successful case execution.
INITIATING CUE: The Reactor Engineer requests that you authorize the new RMSI.
NRC LIMERICK INITIAL EXAMINATION 10/2008
-I Limerick Generating Station Job Performance Measure Evaluate Jet Pump Operability and Determine Tech Spec Implications JPM Number: SRO AI-2 Revision Number: 2 Date:
1011 12008 Developed By: Haagensen Author Validated By:
Monahan Facility Technical Representative Review By:
Caruso Examiner Approved By: Caruso Chief Examiner 9/29/08 Date 10/1/08 Date 9130108 Date 9130108 Date SSRO A DMlN JPM A 1-2. doc Page 1 of 9
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMIN SRO JPM #A 1-2 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM usina stem 8 throuah 11 below.
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
Task description and number, JPM description and number are identified.
Knowledge and Abilities (KIA) references are included.
Performance location specified. (in-plant, control room, or si m u I a to r)
Initial setup conditions are identified.
Initiating and terminating cues are properly identified.
Task standards identified and verified by Examiner review.
Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date Pilot test the JPM:
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
I O. If the JPM cannot be performed as written with proper responses,
page.
Technical changes and modifications:
- 1. Made minor changes to initiating cue and initial conditions. DONE SSRO ADMIN JPM A1-2.doc Page 2 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMlN SRO JPM #A 1-2 REVISION RECORD (Summary):
- 1. This JPM was revised from the original proposed version by having the SRO complete the same jet pump surveillance as the RO rather than review a completed surveillance. There are a number of SRO(l)s in this class.
- 2. This JPM was revised to add testing the tech spec implications of the jet pump failure for the SROs.
JPM Setup Instructions:
I.
Provide OMS Screen Shots and yellow copy of ST-6-043-320-1, Daily Jet Pump Operability Verification for Two Recirculation Loop Operation (file password - gb3v)
- 2. Provide a copy of Tech Specs for each applicant.
- 3. Provide a calculator to applicant
- 4. Applicant is given instruction to perform ST-6-043-320-1 and report results.
- 5. Applicant is required to determine applicable tech specs TASK STANDARD: The candidate should report the test is unsatisfactory due to failing on A loop drive flow high and A loop jet pumps flow low. Applicant should identify:
Tech Spec LCO 3.4.1.3.a (Recirc Pumps) with an action statement of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to take action to restore recirc loop flows within 5% or 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to take actions required by Tech Spec 3.4.1.1 (Recirc Loops) 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to reduce thermal power Tech Spec LCO 3.4.1.2 (Jet Pumps) be in hot shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
76.2%, and reduce the speed of the recirc pumps to 90%
TASK CON DlTlO NS :
Unit 1 plant conditions are as follows:
Unit 1 was operating at 100%
An unexpected drop in reactor power occurred 0 An unexplained rise in core flow occurred 0 ON-100, FAILURE OF A JET PUMP and OT-I04 (Unexpected / Unexplained Positive or Negative Reactivity Insertion) were entered.
INITIATING CUE:
0 The Control Room Supervisor directs you to perform ST-6-043-320-1, Daily Verification of Jet Pump Operability for Two Recirculation Loop Operation and report the results and analyze for tech spec implications (if any).
Information for Evaluators Use:
UNSAT reauires written comments on rewective steD.
SSRO A DMlN JPM A 1-2. doc Page 3 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marksd as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The time clock starts when the candidate acknowledges the initiating cue.
SSRO A DMlN JPM A 1-2. doc Page 4 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 A DMlN SRO JPM #A 9 -2 Operators Name:
Job
Title:
Title:
Evaluate Jet pump Operability and Determine Tech Spec Implications JPM Number: SRO A1-2 Revision Number: 0 K/A Number and Importance:
Generic 2.1.I9 ability to use Plant computers to Evaluate System or Component Status (CFR: 41. I O / 45.12) IMPORTANCE SRO 3.8 Suggested Testing Environment: Classroom - Group Actual Testing Environment:
Testing Method: Table-top - Group Alternate Path: No Time Critical: No Estimated Time to Complete:
Faulted: Yes Actual Time Used:-I 5-minutes References : ST-6-043-320- 1 EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0
No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
Evaluators Name:
(Print)
Evaluators Signature:
Date:
SSRO A DMlN JPM A 1-2. doc Page 5 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMIN SRO JPM #AI-.?
NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT
- 1. Hand the applicant:
PMS computer screen shots 0
Calculator 0
JPM cue sheet
~
- 2. STEP 4.3.1.3 Determine if Loop A flow is within 10% of the loop flow values on the established pump speed-loop flow c ha ract e r ist i c cu rve
- 3. Step 4.3.2.3 Determine if Loop B flow is within 10% of the loop flow values on the established pump speed-loop flow characteristics curve
- 4. Step 4.3.3.4 Determine if the value of total core flow is within 10% of the established Total Core Flow value derived from Recirc Loop Flow Measurements
- 5. Step 4.3.4.4 Determine if Loop A jet pump diffuser-to-lower plenum differential pressure is within 10% of the established patterns STANDARD Review the handouts Determines that loop A is NOT within the limits -
UNSAT.
Examiner cue: If asked for recirc pump flow from FR 1 R614 point 1, inform the applicant this is 47,146 gpm.
Determines that loop B is within the limits - SAT Examiner cue: If asked for recirc pump flow from FR 1 R614 point 2, inform the applicant this is 40,642 gpm.
Determine that total core flow is within the limits - SAT.
Determine that some of the jet pumps on Loop A are NOT within the limits - UNSAT.
SAT UNSAT Comment Number SSRO ADMIN JPM A1-2.doc Page 6 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 II ELEMENT
- 6. Step 4.3.5.4 Determine if Loop B jet pump diffuser-to-lower plenum differential pressure is within 10% of the established patterns
- 7. Verify at least two of the step combinations in the surveillance are satisfactory:
drive flow) 4.3.1.3 and 4.3.2.3 (Pump speed vs.
4.3.3.4 (Total loop flow vs. total core flow)
STANDARD
~
Determine that all of the jet pumps on Loop B are within the limits - SAT Determine that two of three areas are UNSAT and the overall ST results are UNSAT UNSAT + SAT = UNSAT SAT UNSAT + SAT = UNSAT 2 UNSAT + 1 SAT = UNSAT Report the unsatisfactory results - The A jet pumps have failed the surveillance test.
SAT UNSAT Cornu t SSRO ADMlN JPM A 1-2.doc Page 7 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008
-1
- 8 Determine Tech Spec implications of the failed Jet Pump su rvei I la nce CUE: (You may stop here. You have reached the termination criteria for this JPM)
JPM Stop Time STANDARD
- 1. Tech Spec LCO 3.4.1.3.a (Recirc Pumps) with an action statement of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to take action to restore recirc loop flows within 5% or 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to take actions required by Tech Spec 3.4.1.1 (Recirc Loops) which requires 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to reduce thermal power < 76.2%, and reduce the speed of the recirc pumps to 90%.
- 2. Tech Spec LCO 3.4.1.2 (Jet Pumps) be in hot shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Examiner Note: If the applicant only focuses on the Jet Pump Tech Spec, ask if there are any other applicable Tech Specs. BOTH Tech Specs are required for a com plete answer.
I SAT UNSAT Comment
! Number SSRO ADMlN JPM A1-2.doc Page 8 of 9
NRC LIMERICK INITIAL EXAMINATION 7 0/2008
Unit 1 plant conditions are as folloi 0 Unit 1 was operating at 100%
0 An unexpected drop in reactor power occurred 0 An unexplained rise in core flow occurred 0 ON-100, FAILURE OF A JET PUMP and OT-I04 (Unexpected / Unexplained Positive or' Negative Reactivity Insertion) were both entered.
0 The Control Room Supervisor directs you to perform ST-6-043-320-1, Daily Verification of Jet Pump Operability for Two Recirculation Loop Operation and report the results and analyze for tech spec implications (if any).
INITIATING CUE:
NRC LIMERICK INITIAL EXAMINATION 10/2008
-I Limerick Generating Station Job Performance Measure Review RHR Pump, Valve and Flow test and Determine Required Actions JPM Number: SRO A2 Revision Number: 0 Date:
1011 108 Developed By:
Validated By:
Review By:
Approved By:
Haagensen Author Monahan Facility Representative Tomlinson Examiner Caruso Chief Examiner 9/26/08 Date 10/1/08 Date 9/26/08 Date 9126108 Date SRO ADMIN JPM A2.doc Page 1 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
~
~
~~
ADMlN JPM SRO A-2 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
- 1. Task description and number, JPM description and number are id e nt ified.
- 2. Knowledge and Abilities (WA) references are included.
- 3. Performance location specified. (in-plant, control room, or simulator)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
I O. If the JPM cannot be performed as written with proper responses,
SRO ADMIN JPM A2.doc Page 2 of 9
NRC LIMERICK INITIAL EXAMINA TlON 10/2008 I
I ADMlN JPM SRO A-2 REVISION RECORD (Summary):
I.
JPM Setup Instructions:
- 1. Hand out the following materials 0
ST-6-051-234-2 (D RHR Pump, Valve and Flow Test) completed surveillance TASK STANDARD:
The applicant determines that an immediate retest of HV-051-2F004D is required. Once retested, the valve is NOT declared inoperable but is referred to engineering for a 96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> evaluation.
The applicant should not declare this valve to be inoperable.
TASK CONDITIONS:
0 You are the Work Control Supervisor.
0 ST-6-051-234-2 (D RHR Pump, Valve and Flow Test) has just been completed and passed to you for review.
INITIATING CUE:
You are directed to perform review as the Work Control Supervisor for the completed D Loop RHR Pump. Valve, and Flow Test.
Information for Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
SRO ADMIN JPM A2.doc Page 3 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008
.I ADMIN JPM SRO A-2 Operators Name:
Job
Title:
0 NLO 0
STA 0
Title:
Review RHR Pump, Valve and Flow Test and Determine Required Actions JPM Number: SRO A2 Revision Number: 0 KIA Number and Importance: 2.2.12 Knowledge of surveillance procedures.
(CFR: 41.10/45.13)
IMPORTANCE RO 3.7 SRO 4.1 Suggested Testing Environment: Classroom - Individual Actual Testing Environment:
Testing Method: Individual - Table top Alternate Path: Y Time Critical: No Estimated Time to Complete:
Actual Time Used:
minutes
References:
Faultec. I ST-6-051-234-2 EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
0 Yes 0 No Note: Any grade of UNSAT requires a comment.
SRO ADMIN JPM A2.doc Page 4 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008
(Print)
Evaluators Signature:
Date:
Descrbtion:
Original Development Notes:
Provide copy of completed ST on green paper Cue:
You are directed to perform review as the Work Control Supervisor for the completed D Loop RHR Pump, Valve, and Flow test.
The test contains an error in that the RO did not identify that the valve stroke time for the RHR suction valve F004D is in the ALERT range Candidate should determine that the valve stroke time for the RHR suction valve F004D is in the ALERT range and should be re-tested, with the potential that the valve will be operable, inoperable immediately, or require Engineering 96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> eval based on the re-test.
Valve data is on Attachment 1 Evaluation criteria is on Page 11 and in the precautions 10/1/08 - 1. Added peer check initials to all applicable steps - need to rescan procedure.
SRO ADMIN JPM A2.doc Page 5 of 9
NRC LIMERICK INITIAL EXAMINATION 70/2008 7
ADMlN JPM SRO A-2 NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT allow time for the applicants to read and ask questions.
- 2. When applicants state they understand their task and are ready to begin, hand out the competed copy of ST-6-051-234-2 and note the start time.
- 3. Review ST-6-051-234-2 and note deficiencies
- 4. Determine what needs to be done to address the excessive stroke time for HV-051-2F004D per section 4.4.1.3.
STANDARD Ready to begin JPM Start JPM On Attachment 1, the valve stroke time for HV-051-2F004D is outside of the acceptable range but within the max allowable time.
HV-051-2F004D shall be immediately retested.
Examiner Cue: If the applicant hesitates to retest the valve because of system conditions, inform the applicant that the system conditions still support the valve test.
Examiner Cue: The valve test team is standing by with their instrumentation ready to conduct any further testing required.
Examiner Cue: if the applicant states that he would declare the valve inoperable without conducting a retest, determine the reason for this statement.
SAT UNSAT SRO ADMlN JPM A2.doc Page 6 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008
-I ELEMENT
- 5. Conduct an immediate retest of HV-051-2F004D in the closed direction. Reopen this valve and stroke it closed.
- 6. Evaluate the retest stroke time per section 4.4.3.6.
- 7. Initiate appropriate remedial actions as specified in section 3.9.
I 7
STANDARD Examiner Cue: If the applicant states that retesting the valve constitutes preconditioning and he would elect to employ the option to declare the valve inoperable, respond as the Shift Manager that an immediate retest is required. This direction should cause him to loop back to the retest section of the JPM Examiner Cue: The retest shows that the HV-051-2F004D closing stroke time is 140.25 seconds.
Determine the retest shows that the stroke time is still outside of the acceptable range but within the MAX Allowable stoke time.
Determine that section 4.4.3.6 refers the applicant to the precaution in section 3.9 3.9.1 Immediately notify SSV
- 3.9.2 initiate a Potential LCO (PLCO) Entry "3.9.3 initiate an AIR to perform an analysis of stroke time data to verify the new stroke time represents acceptable operation.
3.9.4 Document the AIR number in the Additional ActionlTest Comments section
- 3.9.5 Notify the EDM that analysis of the stroke time data MUST be completed within 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />.
AD SAT 1IN JPM UNSAT RO A-Comn Num SRO ADMlN JPM A2.doc Page 7 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 ELEMENT I
- 8. JPM completion occurs when the applicant decides that the valve is either:
JPM Stop Time STANDARD Examiner Note: If the applicant decides to declare the valve inoperable because he does not recognize that he should conduct an immediate retest, this meets JPM failure criterion.
Termination the JPM - note the time.
~-
I SAT UNSAT 1 Comrnent Number
+-
SRO ADMIN JPM A2,doc Page 8 of 9
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
~
ADMlN JPM SRO A-2 HANDOUT PAGE TAS K C 0 N D I TI 0 N S :
0 You are the Work Control Supervisor for the day.
0 ST-6-051-234-2 (D RHR Pump, Valve and Flow Test) has just been completed and passed to you for review and approval.
INITIATING CUE:
You are directed to perform the review as the Work Control Supervisor for the completed D Loop RHR Pump, Valve, and Flow Test.
SRO ADMlN JPM A2.doc Page 9 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 1
Limerick Generating Station Job Performance Measure Authorize Liquid Radioactive Inventory Release From the Floor Drain Sample Tank JPM Number: SRO A3 Revision Number: 0 Date:
10/1/2008 Developed By:
Validated By:
Haagensen Author Monahan Facility Representative 9/26/08 Date 10/1/08 Date Review By:
Approved By:
Caruso Examiner 9/26/08 Date Caruso Chief Examiner 9/26/08 Date SRO ADMIN JPM A3.doc Page 1 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMIN JPM #SRO /is JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
- 1. Task description and number, JPM description and number are identified.
- 2. Knowledge and Abilities (KIA) references are included.
- 3. Performance location specified. (in-plant, control room, or simulator)
- 4. Initial setup conditions are identified.
- 5. Initiating and terminating cues are properly identified.
- 6. Task standards identified and verified by Examiner review.
- 7. Critical steps meet the criteria for critical steps and are identified with an asterisk ().
- 8. Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
then revise the JPM.
- 9. Pilot test the JPM:
IO. If the JPM cannot be performed as written with proper responses,
SRO ADMlN JPM A3.doc Page 2 of 7
NRC LIMERICK INITIAL EXAMlNA TlON 10/2008 I
ADMIN JPM #SRO A3 REVISION RECORD (Summary):
- 1.
JPM Setup Instructions:
- 1. Hand out the following materials 0
Provide a completed copy of S63.1.C (Inventory Release from 00T308 Floor Drain Sample Tank Number 2 to Cooling Tower Blowdown Line)
Applicant should identify that cooling tower blowdown flow is below the required 5000 gpm and should NOT authorize the release TASK STANDARD:
TAS K C 0 N D IT1 0 N S :
- Floor Drain Sample Tank #2 has been sampled satisfactorily for river release
- The RWEO is performing S63.1.C and has requested FSSV review and approval to
- The RWEO has the discharge permit ST-5-061-570-0 which was received from Chemistry
- Cooling tower blowdown flow is now at 4000 gpm.
- No Hold Pond release is in progress.
You are direct to perform the shift supervisory review required per S63.1.C Step 4.3.7.
When complete, note your answer on the JPM cue sheet.
commence release to the river.
indicating FDST 2 is sat for river release.
INITIATING CUE:
Information for Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
SRO A DMlN JPM A3. doc Page 3 of 7
I NRC LIMERICK INITIAL EXAMINA TlON 10/2008 I
ADMIN JPM #SRO A3 Operators Name:
Job
Title:
0 NLO 0
STA 0
Title:
Review and Approve a Radioactive Liquid Discharge JPM Number: SRO A-3 Revision Number: 0 KIA Number and Importance:
(CFR: 41.I 1 / 43.4 I45.10)
IMPORTANCE RO 3.8 SRO 4.3 2.3.1 1 Ability to control radiation releases.
Suggested Testing Environment: Classroom - Group Actual Testing Environment: Classroom Testing Method: Table top - Group Faulted: No Alternate Path: No Time Critical: No Estimated Time to Complete:
Actual Time Used:
minutes References :
- 1. S63.1.C rev 29 (Inventory Release from 00T308 Floor Drain Sample tank Number 2 to Cooling Tower Blowdown Line EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0 No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
SRO ADMIN JPM A3.doc Page 4 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMlN JPM #SRO A3 Evaluators Name:
(Print)
Eva I uators S ig nature :
Date:
==
Description:==
Development notes:
9/24 Original Version:
Initial conditions:
Plant conditions are as follows:
Floor Drain Sample Tank #2 has been sampled satisfactorily for river release The RWEO is performing S63.1.C and has requested FSSV review and approval to commence release to the river The RWEO has the discharge permit ST-5-061 -570-0 which was received from Chemistry indicating FDST 2 is sat for river release Cooling tower blowdown flow is 4000 gpm No Hold Pond release is in progress The following indications are observed on the OOC303 panel in the RWCR 63-0047 OPEN HV-63-050 OPEN HV-63-051 OPEN HV-63-055 OPEN Applicant should identify that cooling tower blowdown flow is below the required 5000 gpm and should not authoriz:e the release You are direct to perform the supervisory review required per S63.1.C Step 4.3.7 Provide a copy of S63.1.C l o l l Technical Review
- 1. Added examiner cue to JPM step 3.
- 2. Need to initial off the steps in S.63.1.C instead of using check marks. Rescan procedure with initials.
SRO ADMlN JPM A3,doc Page 5 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMIN JPM #SRO A3 NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time ELEMENT
- 1. Hand out the JPM cue sheet and a completed copy of S63.1.C
- 2. Hand out a completed copy of S63.1.C for review.
- 3. Review the completed copy of S63.1.C and the JPM Cue sheet.
- 4. Determine if the release can be authorized.
- 5. Hand in JPM at completion.
1 JPM Stop Time STANDARD SAT applicants acknowledge they are ready to begin the JPM.
All applicants begin the JPM Log the start time.
Review S63.1.C and JPM cue sheet.
If the applicant determines the release can be authorized, initial step 4.3.7 on S63.1.C.
This is incorrect.
If the applicant determines the release should NOT be authorized, then do NOT initial step 4.3.7 of S63.1.C and complete the JPM answer sheet stating that the cooling tower blowdown flow is less than the required amount (5000 gpm).
Log completion time.
UNSAT Comment Number SRO ADMIN JPM A3.doc Page 6 of 7
NRC LIMERICK INITIAL EXAMINATION 10/2008
-1 ADMlN JPM #SRO A3 HANDOUT PAGE TASK CONDITIONS:
- Floor Drain Sample Tank #2 has been sampled satisfactorily for river release
- The RWEO is performing S63.1.C and has requested FSSV review and approval to
- The RWEO has the discharge permit ST-5-061-570-0 which was received from Chemistry
- Cooling tower blowdown flow is now at 4000 gpm
- No Hold Pond release is in progress commence release to the river indicating FDST 2 is sat for river release INITIATING CUE:
You are direct to perform the shift supervisory review required per S63.1.C Step 4.3.7.
When complete, note your answer on the JPM cue sheet,below.
ANSWER Key:
Circle the appropriate answer:
- 1. Release is APPROVED.
- 2. Release is NOT approved: state the reason for disapproval below:
SRO ADMlN JPM A3.doc Page 7 of 7
e I
1 NRC LIMERICK INITIAL EXAMINATION 10/2008 Limerick Generating Station Job Performance Measure Classify the Event and Recommend KI JPM Number: SRO A-4 Revision Number: 1 Date:
1011 /2008 II Developed By: Haagensen 9/26/08 Validated By:
Review By:
Approved By:
Author Date Monahan 1 0/1/08 Facility Representative Date Caruso 9/26/08 Examiner Date Caruso 9/26/08 Chief Examiner Date SRO ADMlN JPM A4.doc Page 1 of 7
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
~
~~~
ADMlN JPM #SRO A4 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE: All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 8 through 11 below.
7
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
Task description and number, JPM description and number are identified.
Knowledge and Abilities (WA) references are included.
Performance location specified. (in-plant, control room, or si m u I a to r)
Initial setup conditions are identified.
Initiating and terminating cues are properly identified.
Task standards identified and verified by Examiner review.
Critical steps meet the criteria for critical steps and are identified with an asterisk (*).
Verify the procedure referenced by this JPM matches the most current revision of that procedure:
Procedure Rev.
Date Pilot test the JPM:
- a. verify cues both verbal and visual are free of conflict, and
- b. ensure performance time is accurate.
I O. If the JPM cannot be performed as written with proper responses,
page-SRO ADMlN JPM A4.doc Page 2 of 9
I NRC LIMERICK INITIAL EXAMINA TlON 7 0/2008 I
~~~~
ADMlN JPM #SRO A4 REVISION RECORD (Summary): The original JPM was used on the 2005 Peach Bottom NRC Exam.
- 1. Revised to include an event classification in addition to KI recommendation. Also changed the decision on KI from do not authorize to authorize.
JPM Setup Instructions:
- 1. Hand out the following materials 0
EP-AA-113 Personnel Protective Actions 0
EP-AA-113-F-03 Thyroid Blocking Agent Authorization Form - completed with the exception of the Station Emergency Director authorization EP-AA-1008 Table LGS 3-1 Emergency Action Level (EAL) Matrix TASK STANDARD:
1, Classify the event as a general emergency
- 2. Complete the initial notification form
- 3. Determine that Field Monitoring Teams should take KI as a precautionary measure TASK CONDITIONS:
- 1. A design basis earthquake caused a loss of offsite power and a large break LOCA at 0200
- 2. Multiple failures in safety systems caused the operators to conduct an emergency
- 3. Drywell pressure peaked at 55 psig and then dropped rapidly to 3 psig.
- 4. Secondary containment radiation levels increased substantially.
- 5. RPV level dropped as low as -1 70 inches.
- 6. The dose projection estimate indicates expected doses of 3 rem TEDE and 35 rem CDE (thyroid) for the field monitoring teams.
- 7. The DIV 1 and 2 EDGs have failed.
- 9. The OSC has been activated and is preparing to dispatch the field monitoring teams to today.
depressurization in T-112.
been fully activated (the earthquake caused damage to local roads) measure radiation levels at the site boundary.
SRO ADMlN JPM A4.dOC Page 3 of 9
NRC LIMERICK /NlTlAL EXAMINATION 7 0/2008 ADMlN JPM #SRO A4 IO. A Site Area Emergency was declared at 021 0 and the offsite notification message was 11.The time is now 0230 and the following plant conditions exist:
transmitted at 0220.
Drywell radiation levels = 1.5E+02 Whr 0
RPV level = -150 inches and recovering slowly on firewater 0
You are the Emergency Director until relieved.
INITIATING CUE:
- 1. Review the event classification and update if necessary - list the current classification and EAL on the answer sheet. Do not fill out a notification form.
- 2. The OSC Director has requested to deploy the field monitoring teams to measure radiation levels at the site boundary. He requests to administer KI (thyroid Blocking Agent) to the Field Monitoring Team members. Indicate on your answer sheet if KI should be administered or not administered to Field Monitoring Team members as they are dispatched into the field
- 3. This is a TIME CRITICAL JPM.
Please review the initial conditions and initiating cues, ask any questions and let the proctor know when you are ready to begin the JPM. The following references will be handed out at the start of the JPM:
o EP-AA-113 Personnel Protective Actions o
o EP-AA-113-F-03 Thyroid Blocking Agent Authorization Form - completed with the exception of the Station Emergency Director authorization EP-AA-1008 Table LGS 3-1 Emergency Action Level (EAL) Matrix - HOT and COLD conditions Information for Evaluators Use:
UNSAT requires written comments on respective step.
- Denotes CRITICAL steps.
Number any comments in the Comment Number column. Then annotate that comment in the Comments section. The comment section should be used to document the reason that a step is marked as unsatisfactory and to document unsatisfactory performance relating to management expectations.
Some operations that are performed from outside of the control room may require multiple steps. These items may be listed as individual steps in this JPM. It is acceptable for the candidate to direct the local operator to perform groups of procedure steps instead of calling for each individual item to be performed.
The timeclock starts when the candidate acknowledges the initiating cue.
SRO ADMlN JPM A4.doc Page 4 of 9
I NRC LIMERICK INITIAL EXAMINATION 10/2008 I
ADMlN JPM #SRO $44 Operators Name:
Job
Title:
0 NLO 0
STA 0
Title:
Reclassify the event and determine if KI should be administered to FMTs JPM Number: SRO A4 Revision Number: 1 KIA Number and Importance:
Suggested Testing Environment: Classroom - Group 2.4.29 Knowledge of the emergency plan. ITS SRO 4.4 Act ua I Testing Environment : Class room Testing Method: Tabletop Faulted: No Alternate Path: No Time Critical: 15 minutes Estimated Time to Complete: 15 minutes Actual Time Used:
minutes 0
References:
EP-AA-113 Personnel Protective Actions 0
EP-AA-113-F-03 Thyroid Blocking Agent Authorization Form - completed with the exception of the Station Emergency Director authorization 0
EP-AA-1008 Table LGS 3-1 Emergency Action Level (EAL) Matrix EVALUATION
SUMMARY
- 1. Were all the Critical Elements performed satisfactorily?
- 2. Was the task standard met?
0 Yes 0 No The operators performance was evaluated against the standards contained in this JPM, and has been determined to be:
0 Satisfactory 0
Unsatisfactory Comments:
Note: Any grade of UNSAT requires a comment.
SRO ADMlN JPM A4.doc Page 5 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMIN JPM #SRO A4 Evaluators Name:
(Print)
Eva I u a to rs Signature :
Date:
==
Description:==
Development notes:
This JPM was developed from a Peach Bottom JPM but substantially modified to include an upgrade in the classification as well as the decision to authorize KI. The original JPM reached a determination that KI was NOT authorized. The modification was that KI is now authorized for the Field Monitoring Teams.
- 1. The intent of this JPM is to place the applicant in a condition where the event classification should be upgraded to a GE due to the loss of containment and RCS barrier - and the potential (but not actual) loss of the clad.
- 2. KI should be administered to field monitoring team members
- 3. It is not necessary to fill out the offsite notification form for this JPM.
- 4. The answer key will be used to collect answers from the applicants.
- 5. This is a time critical JPM. The event should be reclassified and the decision to administer KI should be made within 15 minutes from the start.
10/1 Technical review comments:
- 1. Change to initial conditions (-1 70 statement)
- 2. Add in initiating cue for time critical data collection.
The licensee questioned the 15 minute time critical limit. They said that only the classification had to be completed within 15 minutes. I stated that completing both the classification upgrade as well as the decision to authorize KI was appropriate for the 15 minute time clock. If they continue to object to the 15 minute time clock, then I told them we would change the clock from 15 to 30 minutes BUT include the completion of the offsite notification message form AND determination of offsite PARS in the JPM.
They stated they would see how it validated.
The 15 minute time limit is clearly appropriate for the classification decision and the authorization to dispatch the Field Monitoring Teams is clearly time sensitive. It is considered appropriate for a competent operator to be able to make these decisions within 15 minutes.
SRO ADMIN JPM A4.doc Page 6 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 STANDARD SAT UNSAT j
Applicants review initial conditions and initiating cues.
ADMlN JPM #SRO A4 Comment Number NOTE: Critical Element(s) indicated by
- in Performance Checklist.
PERFORMANCE CHECKLIST:
JPM Start Time (TIME CRITICAL)
ELEMENT II
- 1. Applicants review the handout sheet and ask any questions regarding the initial conditions or initiating cues.
- 2. Log the JPM start time and handout the references
- 3. Review the EALs and determine the appropriate event classification.
- 4. Review EP-AA-113 (Personnel Protective Actions) and determine if KI should be administered to Field Monitoring Teams.
- 5. Collect the answer pages when 15 minutes has elapsed - note the stop time for each individual.
JPM Stop Time Start the JPM - note the start time.
The event should be classified as a General Emergency -
EAL Fission Product Barrier Matrix FG-1.
KI should be administered to FMT members because the potential for a lost clad barrier and the release offsite.
Hand in answer pages.
SRO ADMlN JPM A4.doc Page 7 of 9
NRC LIMERICK INITIAL EXAMINATION 10/2008 ADMIN JPM #SRO A4
- 1. A design basis earthquake caused a loss of offsite power and a large break LOCA at 0200
- 2. Multiple failures in safety systems caused the operators to conduct an emergency
- 3. Drywell pressure peaked at 55 psig and then dropped rapidly to 3 psig.
- 4. Secondary containment radiation levels increased substantially.
- 5. RPV level dropped as low as -1 70 inches.
- 6. The dose projection estimate indicates expected doses of 3 rem TEDE and 35 rem CDE (thyroid) for the field monitoring teams.
- 7. The DIV 1 and 2 EDGs have failed.
- 9. The OSC has been activated and is preparing to dispatch the field monitoring teams to 10.A Site Area Emergency was declared at 021 0 and the offsite notification message was 11.The time is now 0230 and the following plant conditions exist:
HANDOUT PAGE today.
depressurization in T-I 12.
been fully activated (the earthquake caused damage to local roads) measure radiation levels at the site boundary.
transmitted at 0220.
0 Drywell radiation levels = 1.5E+02 Whr RPV level = -1 50 inches and recovering slowly on firewater 0
You are the Emergency Director until relieved.
INITIATING CUE:
- 1. Review the event classification and update if necessary - list the current Classification and EAL on the answer sheet. Do not fill out a notification form.
- 2. The OSC Director has requested to deploy the field monitoring teams to measure radiation levels at the site boundary. He requests to administer KI (thyroid Blocking Agent) to the Field Monitoring Team members. Indicate on your answer sheet if KI should be administered or not administered to Field Monitoring Team members as they are dispatched into the field
- 3. This is a TIME CRITICAL JPM.
Please review the initial conditions and initiating cues, ask any questions and let the proctor know when you are ready to begin the JPM. The following references will be handed out at the start of the JPM:
o EP-AA-113 Personnel Protective Actions o
o EP-AA-113-F-03 Thyroid Blocking Agent Authorization Form - completed with the exception of the Station Emergency Director authorization EP-AA-I008 Table LGS 3-1 Emergency Action Level (EAL) Matrix - HOT and COLD conditions SRO ADMIN JPM A4.doc Page 8 of 9
I NRC LIMERICK INITIAL EXAMINATION 70/2008 I
ADMIN JPM #SRO A4 Answer Sheet:
Hand in this answer sheet upon completion of the JPM. This will be collected when the critical time has elapsed.
- 1. Circle the correct classification:
- a. NOUE
- b. Alert
- c. Site Area Emergency
- d. General Emergency
- 2. List the EAL used as the basis for your classification decision:
- 3. Circle the correct answer regarding whether KI be administered to Field Monitoring Team Members?
- a. Administer KI prior to deployment