AmerenUE Callaway Plant PO Box 620 Fulton, MO 65251 October 29, 2008 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 ULNRC-05559 v"Amerem Ladies and Gentlemen:

UE DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.

FACILITY OPERATING LICENSE NPF-30 ADDITIONAL INFORMATION PROVIDED TO MISSOURI DNR CONCERNING GROUND WATER MONITORING The enclosed Union Electric Company (AmerenUE) letter contains additional information provided to the Missouri Department of Natural Resources (DNR) pertaining to the Ground Water Monitoring Program for Callaway Plant. Although the enclosed letter involves no changes to the Callaway NPDES Permit itself, the information is being provided as it may be of public interest in accordance with Callaway Plant Operating License-NPF-30, Appendix B, Section 3.2.

This letter does not contain any new commitments. Please contact Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing, at 573-676-6479 for any questions you may have regarding this issue.

Sincerely, Luke H. Graessle Manager, Regulatory Affairs GPG/nls

Enclosure:

Ameren letter to the Missouri Department of Natural Resources dated October 8, 2008.

iiZ~59 a subsidiary of Ameren Corporation

ULNRC-05559 October 29, 2008 Page 2 cc:

Mr. Elmo E. Collins, Jr.

Regional Administrator U.S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Mohan C. Thadani (2 copies)

Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O-8G14 Washington, DC 20555-2738

ULNRC-05559 October 29, 2008 Page 3 Index and send hardcopy to QA File A160.0761 Hardcopy:

Certrec Corporation 4200 South Hulen, Suite 630 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)

Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution:

A. C. Heflin F. M. Diya T. E. Herrmann S. M. Maglio T. B. Elwood L. H. Graessle S. L. Gallagher L. M. Belsky (NSRB)

Mr. Ron Reynolds, Director (SEMA)

Mr. Edward Gray, Senior REP Planner (SEMA)

Mr. John Campbell, REP Planner (SEMA)

Ms. Diane M. Hooper (WCNOC)

Mr. Dennis Buschbaum (TXU)

Mr. Scott Bauer (Palo Verde)

Mr. Stan Ketelsen (PG&E)

Mr. Wayne Harrison (STPNOC)

Mr. John O'Neill (Pillsbury Winthrop Shaw Pittman LLP)

Mr. Floyd Gilzow (DNR)

Enclosure to ULNRC-05559 Ameren Letter to the Missouri Department of Natural Resources Dated October 8, 2008 (97 Pages)

AmerenUE PO Box 620 Callaway Plant Fulton, MO 65251 October 8, 2008 AURA 2008031 Mr. Robert K. Morrison, Chief Water Pollution Control Branch Post Office Box 176 Jefferson City, Missouri 65102-0.176

SUBJECT:

Callawav Plant Groundwater Monitoring Program

  • '4 merea

Dear Mr. Morrison:

1F This letter provides our response to your additional questions and concerns related to Callaway's groundwater monitoring program submitted in your letter dated July 22, 2008. As discussed in our meeting at Callaway Plant on September 11, 2008, a more complete description of the plant design. and our ground water monitoring wells is included to provide a better understanding of our overall program.

Callaway has a total of six ground water monitoring wells along with the Ground Water Sump (GWS) installed at strategic locations within the area surrounding the main plant structures known as the power block. The power block was constructed within a bathtub shaped excavation when the plant was built during the late 1970's.

The excavated area is approximately 30 feet deep situated on top of the Greydon Chert and is lined with approximately three feet of compacted clay material. After placement of building foundations and ancillary infrastructure (pipes, conduits, etc.)

the excavation was then back filled with a compacted granular structural fill material and capped with an additional three feet of clay. A cohesive fill consisting of modified loess (clay) was used for several locations to block water flow and prevent seepage along infrastructure pathways to and from this power block area to other areas such as the ultimate heat sink pond. The reactor building, control building, auxiliary building, radwaste building, and portions of the turbine building were constructed near the base of this bathtub. Several drawings were included in Attachment F to the previous letter dated April 18, 2008. These drawings provide cross-sectional views of the Power Block excavated area. Twenty five additional moniioring wells for Unit I are located on the plant site outside of this power block area. In addition, numerous wells have been installed on the Callaway Plant site during the past few years to assist in preparing the environmental report for the proposed Unit 2.

The ground water sump and pump were installed during the mid 1990s to assist in

.he remediation of a site fuel oil leak. This sump is located near the reactor building and the comer of the fuel building and is normally pumped continuously at a rate of near 65 gpm to a waste oil separator. The GWS pump was actually shut down for a subsidiary of Ameroa Corporation

AURA 2008031 October 8, 2008 about 4 weeks this past summer to support extended maintenance on portions of the waste oil treatment system. Normally the GWS pump is taken out of service for approximately one day every 6 months for routine maintenance or for pump replacement. Therefore, the almost continuous pumping of the GWS pump should eventually draw any potential radioactive contamination within the power block area towards the ground water sump.

Callaway has four specific radioactive source areas within the power block area that could demonstrate a potential risk of leakage to the ground. For reasons stated below, we believe the likelihood of any leakage from these systems or components is extremely small. The four areas include the spent fuel pool liner and transfer canal, the Refueling Water Storage Tank (RWST) and associated underground piping, the underground piping associated with the two Discharge Monitor Tanks (DMTs) and the current plant blowdown/discharge piping to the river. 1) The spent fuel pool is located inside of the fuel building and the bottom of this stainless steel lined concrete pool is approximately six feet above ground level. A leakage detection system of tell-tale drains is installed under this pool and transfer canal to collect any leakage. These tell-tale drains are routed to a small tank where the level is monitored by the plant computer. A system engineer routinely trends and monitors this tank level and any leakage observed. 2) The stainless steel RWST is located above ground and adjacent to the fuel building and the radwaste building.

All associated underground piping is welded stainless steel. 3) The two stainless steel DMTs are located next to the radwaste building and are surrounded by a concrete dike designed to contain one tank volume. All underground piping associated with these tanks is welded stainless steel. 4) As you are aware, the old plastic and carbon steel blowdown discharge piping has experienced several breaks or leaks over the years. A new high density polyethylene pipe line is currently being installed and the tie in should be completed before the end of the year. This installation has taken longer than expected due to the abnormal rainfall and flooding we have experienced several times this year.

Tritium is generally the radionuclide expected to have the highest concentration in these radioactive systems. As it moves through the environment as water, it is most likely the first radionuclide to be detected should a leak or spill to ground water occur. However, there is no effective method to analyze tritium present at or near environmental levels with an in-line detector. The EPA limit for tritium in drinking water is 20,000 pCi/liter. Callaway can measure tritium in water samples at concentrations down to approximately 6,000 pCi/liter in our on-site laboratory. By comparison, the contract environmental laboratory we use (located in Chicago) can measure tritium levels in environmental samples to near 200 pCi/liter. Several samples collected from the power block wells have shown positive tritium concentrations at or slightly above background levels. Although these concentrations are very close to background levels, we believe that tritium is being washed out of the air by rainfall and condensation from allowed airborne releases of tritium gas. Tritium gas is released in very low concentrations from both the unit vent and the radwaste vent located within the power block area in compliance with NRC regulations.

AURA 2008031 October 8, 2008 Below is our response to your specific request for additional information.

1. What is the maximum and minimum length of time that water contaminated with radioactive materials or uranium would take to travel the distance from the center of the bottom of the reactor building to (a) the Groundwater Sump (GWS) and (b) the other monitoring wells given the porosity of the site material?

Callaway Plant is designed to minimize any leakage of uranium or other radioactive materials from all plant systems and components. For example, the reactor is designed such that the uranium fuel has three barriers to the environment. The first barrier is the Zircaloy-4 fuel cladding surrounding the fuel pellets. The second barrier is the reactor vessel and the third barrier is the three foot thick reinforced concrete containment building (reactor building) that houses the reactor vessel, piping and associated components. Therefore, it is very unlikely that any significant leakage from these systems will occur that would reach groundwater.

Slug tests were recently completed by Paul C. Rizzo Associates, Inc. for several monitoring wells to generate an updated groundwater model for Callaway Unit 1.

Results from two slug tests for wells located within the power block area indicate hydraulic conductivity measurements in the range of 0.4 to 1.0 feet per day. Should a leak occur near the bottom of the center of the reactor building or near the bottom of fuel building, it is estimated that it would take ground water approximately 133 days to reach the ground water sump. The time range for travel will be variable depending on the leak location and the hydraulic gradient created by the ground water sump. Without the ground water sump, leaks would take a significant amount of time (years) to detect in other monitoring wells due to the extremely low hydraulic gradient.

The porosity of the site materials is variable and dependant on the location within the plant. The granular fill located within the bathtub consists of primarily structural granular fill with a limited layer of bedding and clay materials. EDP-ZZ-02002, Backfill/Material, Selection, Preparation, Placement & Compaction (provided in Attachment A), contains requirements for the structural backfill and cohesive fill used for the Unit I power block excavation. The porosity of the structural backfill is estimated to be near 5%, due to the compaction requirement of a minimum dry density of 138.7 pcf. Outside of the power block the soil consists of silty clay with a porosity estimated to be 35% from laboratory tests of the unconsolidated samples. For compacted silty clay used both within and outside of the power block, the impact of compaction requirements and capillary forces is estimated to reduce the porosity to less than 15%. As a result, porosity varies according to soil material, location and use.

2. Assuming a rather short length of travel time, given the porous media, how can quarterly monitoring be justified in a leakage detection situation? Three months is a long time for a leak to cause contamination. Wouldn't a continuous monitoring alarm system provide more timely information if the GWS or monitoring wells

AURA 2008031 October 8, 2008 detected radiation and uranium, or in lieu of that, at least weekly monitoring?

Based on the above discussion, Callaway Plant believes that quarterly monitoring of the ground water wells and the GWS for tritium and principle gamma emitters is adequate to determine any type of leakage in the power block area. Travel time through this material occurs over a period of months. In addition, a large leak or spill would be identified rapidly due to inventory monitoring and routine inspections of plant systems, tanks and components. Small leakage to groundwater would be held-up within the bathtub area and eventually be drawn towards the GWS. Finally as mentioned above, there is no in-line tritium monitor available that would be capable of detecting tritium near background environmental levels.

3. How will Ameren test the groundwater leakage detection system to ascertain if it actually functions as designed? Will this be done by dye tracing or actual Tritium (or other radioactive material) tracing?

Callaway has no plans to perform a test of the leakage detection capability of the monitoring wells within the power block bathtub. Tritium is both a fission product and an activation product and is present in all radioactive systems at Callaway. Our contract environmental laboratory has detected very low levels of tritium in several samples collected from ground water monitoring wells in the power block area.

Tritium has been detected at levels less than 200 pCi/liter. This level is near background and well below the EPA limit of 20,000 pCi/liter for tritium in drinking water.

4. Please send us a copy of the comprehensive groundwater program monitoring document being generated under the requirements of the NEI Groundwater Protection Initiative NEI-07-07, which you indicate will be available in September 2008.

Attachment B contains a copy of Callaway's Ground Water Protection Program procedures. EDP-ZZ-01 136, Ground Water ProtectionProgram, contains the overall guidance for implementing our ground water protection program and meets the requirements of NEI 07-07, Industry Ground Water Protection Initiative - Final Guidance Document. A copy of HTP-ZZ-07101, Radiological Environmental Monitoring Program, is also included. Attachment 4 of this procedure provides details on the groundwater wells and ponds sampled. Finally, we have included a copy of RP-DTI-ENVIRONMENTAL-SPILLRESP that provides direction for Response to Spills or Leaks of Radioactive Material.

5. Ameren Services cites a phenomenon known as washout as the reason why tritium levels are sporadically detected in the monitored points at levels well below MCL. Ameren Services states, "The NRC [Nuclear Regulatory Commission] recognizes this phenomenon and has issued Regulatory Issue Summary (RIS) 2008-03 to provide guidance to licenses." However, Ameren Services does not indicate where the

AURA 2008031 October 8, 2008 gaseous phase tritium originates or how it enters the fill material to then be transported to the groundwater by the washout phenomenon.

Gaseous tritium is routinely released from several locations at Callaway Plant including the unit vent and the radwaste vent (photograph provided in Attachment C). These small quantities of gaseous tritium are released in accordance with 10 CFR 20.2001(a)(3) and reported annually in Callaway's Annual Radiological Effluent Release Report. A copy of this annual report is also sent to the Missouri Department of Natural Resources each year at the same time it is submitted to the NRC. A portion of the gaseous tritium released from the operation of Callaway Plant is believed to condense to the ground around the power block as part of a natural process such as through equipment condensation or by rainfall. Operating experience at many other nuclear plants has been reported providing evidence of tritium concentrating in rainwater collected in the vicinity of the power block areas and in condensate collected from building air conditioners. Callaway has confirmed this phenomenon is occurring with on-site testing of condensate from air conditioning units.

6. Not enough data has been submitted pertaining to groundwater flow in the power block, therefore an assessment as to the validity of the monitoring points chosen is in question. It is not clear if the chosen monitoring points are in the correct location to detect a release from the Reactor and Fuel buildings. An illustration detailing the locations of the piezometers is needed to determine the apparent groundwater flow direction on the site.

The Callaway Unit 1 Final Groundwater Model Report prepared by Rizzo and Associates will be provided as soon as the final document is available. Ground water levels in this area indicate that the ground water flow within the power block bathtub is normally drawn towards the ground water sump as expected. Plant buildings such as the auxiliary building and reactor building do provide a partial barrier to the flows from either side of the buildings but any leakage from the area near or around the fuel building or reactor building should not be affected by these structures as it moves toward the groundwater sump. Therefore, we believe the current monitoring wells located within the power block area provide adequate indication of any leakage to groundwater from plant systems, structures or components.

7. Table 2.4-25 included by Ameren Services contains water level readings from the ten "permanent" piezometers (Mi-M10) located at the facility.

An item to note is that the readings are from July and August 1979 and may not accurately reflect the current conditions. As figure 2.4-30 was not included in Ameren Services response, the locations of the piezometers are not known. It is possible that at least some of the ten piezometers are located in undisturbed areas and most likely the information won't be of much value concerning the perched groundwater zone in the filled areas. Because the location of the piezometers is not known, we cannot make a judgment as to whether the

AURA 2008031 October 8, 2008 chosen monitoring points are accurately located to detect releases from the potential sources at the Callaway Plant site.

Recently a ground water monitoring study was completed of the general site area for the proposed Callaway Unit 2. This study supports the original ground water hydrology study originally completed for Unit 1. However, no permanent piezometers have been placed within the Unit 1 power block structural fill area.

Attachment D provides a drawing showing the current power block monitoring well locations in relation to buildings and components. The yellow rectangle at the roads surrounding the plant buildings indicates the approximate location of the bathtub area beneath the power block. We believe that the ground water sump and the six power block monitoring wells are positioned appropriately to provide indication of any leakage of radioactive material from a system, structure or component within this power block area. In addition, a more detailed cross-sectional drawing is being generated to provide a better understanding of the power block excavation and location of the monitoring wells.

Water levels are recorded by Terracon for each of the monitoring wells when sampling is conducted each quarter. The table below provides water level elevation data recorded during the past three years for the GWS and for the power block wells. In reviewing the ground water elevations, it is apparent that there is generally a depression within this bathtub area, with the GWS being at the lowest elevation compared to the surrounding wells.

POWER BLOCK WELL WATER LEVEL ELEVATION (FEET)

DATE GWS 936 937A 937B 937C 937D 937E 937F April 2006 824.1 827.0 827.6 827.4 July 2006 822.6 826.1 831.6 827.4 827.6 October 2006 826.2 829.3 830.0 830.7 829.8 829.9 830.6 January 2007 827.6 830.5 831.0 832.0 831.0 831.4 832.1 April 2007 828.0 831.4 832.6 831.7 831.9 832.5 July 2007 827.4 830.7 830.9 832.1 831.2 831.4 831.8 832.1 October 2007 825.8 830.7 830.7 832.1 831.1 831.3 831.7 832.0 January 2008 827.9 830.8 831.4 832.3 831.5 831.8 832.2 832.4 April 2008 828.2 831.2 831.8 832.1 832.1 832.6 833.1 833.2 May 2008 825.5 830.8 831.6 832.3 831.6 832.1 832.3 832.3 June 2008 831.1 832.0 831.5 831.7 831.9 832.0 July 2008 830.9 830.1 830.7 831.2 830.6 830.5 831.0 August 2008 830.6 831.5 831.0 831.1 830.1 830.2 1

830.8

  • GWS pump was out of service for approximately one month during July-August 2008.
8. The department requested development of cross-sections in the area of the proposed monitoring wells to depict geologic units, areas of backfill, any structural features (utility of piping trenches) that impact the movement of groundwater, and any other hydrogeologic information

AURA 2008031 October 8, 2008 that may be pertinent at the Callaway Plant site. Ameren Services submitted several construction-era cross-sections for various locations across the plant site. As was stated previously, the submitted cross-sectional diagrams were scaled to largely to be of value in the determination of a groundwater monitoring network for the power block area.

Piping trenches such as those providing barriers for the Essential Service Water (ESW) piping between the ESW pumphouse and the Ultimate Heat Sink (UHS) retention pond are lined with clay type materials to prevent water seepage. In addition, the area surrounding the circulating water piping at the edge of the Power Block was constructed on the Graydon Chert conglomerate and back filled with a clay material to prevent groundwater movement into and out of this area. The drawings supplied previously (Attachment F to Letter dated April 18, 2008) are the only cross-sectional drawings available for the power block area. Larger copies of these drawings can be provided to you upon request.

9. The department requested a complete listing of the radionuclides to be included in the groundwater monitoring program and the sampling methodology, handling and associated laboratory QA/QC information.

Ameren Services indicated that the monitoring points are to be analyzed quarterly for tritium and primary gamma emitters. Ameren Services did not indicate which radionuclides the "primary gamma emitters" include.

A complete list of the "primary gamma emitters" analyzed could include any radionuclide that emits gamma rays within the energy range analyzed and with a half life long enough to allow detection following sampling, shipment, etc. This could include but is not limited to radionuclides such as Co-60, Co-58, Cs-I134, Cs-137, Cs-136, Cr-51, Mn-54, 1-13 1, Zr-89, Rb-86-Sb-122, Np-239, Zr-95, Nb-95, Mo-99, Tc-99m, Zr-97, Nb-97, Ba-140, La-140, Be-7, Fe-59, Sb-124, Sb-125, Ag-ll0m, Zn-65, Cd-109, Ce-141, Ce-144, Ru-105, Ru-103, and Ru-106. All samples ate handled and analyzed to the requirements of Regulatory Guide 4.15, Rev. 1 -

QUALITY ASSURANCE FOR RADIOLOGICAL MONITORING PROGRAMS (NORMAL OPERATIONS)-EFFLUENT STREAMS AND THE ENVIRONMENT and our environmental laboratory's Quality Assurance Manual.

We believe that this response contains much of the additional information you have requested concerning the Callaway Plant groundwater monitoring program.

Unfortunately, the report being prepared to update our current Unit 1 Groundwater Model is not yet complete. This document will be forwarded to you as soon as the final report is received from our contractor. In addition, a drawing is being prepared to provide a better understanding of the power block area. This cross-sectional drawing will include the power block area monitoring wells, details of the excavated bathtub area, general ground water flow and major plant structures. You should receive this additional information by November 30, 2008.

AURA 2008031 October 8, 2008 Should you have additional questions or desire further information, please contact John Pozzo (314-554-2280) or Gail Gary (314-554-2824) of the Environmental Services Department.

Sincerely, Luke H. Graessle Manager, Regulatory Affairs GPG/nls Attachments

AURA 2008031 October 8, 2008 bcc:

S. D. Abraham w/o attachments C. M. Cash w/o attachments C. C. Graham w/o attachments R. E. Farnam/J. S. Geyer w/o attachments J. F. Small/J. H. Howard/D. D. Schultz w/o attachments K. A. Mills/T. J. Loftus w/o attachments J. C. Pozzo/M. F. Bollinger w/o attachments G. P. Gary w/attachments WQ-3.l1.1 w/attachments A160.0502 w/attachments

ATTACHMENT A

wAmerenUE Callaway Plant EDP-ZZ-02002 BACKFILL/MATERIAL SELECTION, PREPARATION, PLACEMENT, &

COMPACTION MINOR Revision 004 Page 1 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 BACKFILL/MATERIAL SELECTION, PREPARATION. PLACEMENT. &

COMPACTION TABLE OF CONTENTS Section Page Number 1.0 PU RPO SE............................................................................................................................................

4 2.0 SCO PE................................................................................................................................................

4 3.0 RESPO NSIBILITIES........................................................................................................................

5 3.1.

Engineering..............................................................................................................................

5 3.2.

Perform ing W ork Group.....................................................................................................

5 3.3.

Supervisor, Quality Control................................................................................................

7 3.4.

Person Supervising Field W ork.........................................................................................

7 3.5.

W ork Group Supervisor....................................................................................................

8 4.0 PR O CEDU RE IN STRU CTIO N S.................................................................................................

9 4.1.

Generic Inform ation........................................................................................................

9 4.1.1. Lim its of Elevation Control.....................................................................................

9 4.1.2. Overflow Points...................................................................................................

9 4.1.3. Protection.....................................................................................................................

9 4.1.4. Tem porary Bracing................................................................................................

9 4.2.

M aterial Designations and Requirem ents..........................................................................

10 4.2.1. Category I Granular Structural Fill........................................................................

10 4.2.2. Category I Granular Structural Backfill................................................................

11 4.2.3. Category I Cohesive Fill.......................................................................................

11 4.2.4. Stabilized Backfill................................................................................................

11 4.2.5. Clay Blanket...............................................................................................................

11 4.2.6. Category I Bedding Material - Sand, (See Car 200704068).................................. 12 4.2.7. Alternate Category I Bedding Material - Aggregate Fines (See Car 200704068)..... 12 4.3.

Installation of Category I Granular Structural Fill.............................................................

13 4.4.

Installation of Category I Granular Structural Backfill....................................................

14 4.5.

Installation of Category I Cohesive Fill.............................................................................

15 4.6.

Installation of Stabilized Backfill..............................................................................

............. 17 4.7.

Installation of Category I Bedding Material - Sand, (See Car 200704068).......................

18 4.8.

Installation of Category I Bedding Material - Aggregate Fines, (See Car 200704068)........ 19 4.9.

Installation of Clay Blanket.............................................................................................

20 5.0 REFEREN CES.................................................................................................................................

21 5.1.

Im plem enting.........................................................................................................................

21 5.2.

Developm ental......................................................................................................................

21 Page 2 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 BACKFILL/MATERIAL SELECTION, PREPARATION, PLACEMENT, &

COMPACTION TABLE OF CONTENTS Section Page Number 6.0 RECO RDS........................................................................................................................................

22 7.0 DEFINITIONS.................................................................................................................................

22 8.0

SUMMARY

OF CHANGES...........................................................................................................

22 A T T A C H M E N T 1, D raw ing Lists...............................................................................................................

23 Page 3 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 BACKFILL/MATERIAL SELECTION, PREPARATION, PLACEMENT, &

COMPACTION 1.0 PURPOSE 1.1.

Describes the responsibilities and actions for the selection, preparation, placement and compaction of the bedding, fill and backfill materials within the Power Block, ESWS and UHS Excavation limits.

1.2.

Provides guideline for proper installation requirements, but NOT to be construed as complete within its entirety. Section 5.0, of this procedure, references additional specifications governing conditions NOT stipulated in this procedure. Such conditions require additional work instructions implemented into the work authorizing document.

NOTE Graydon Chert Conglomerate is hard clay with chert fragments, sandstone and sandy chert combined in its original undisturbed natural state.

1.3.

Provides protection of the Graydon Chert Conglomerate in all locations and the selection, preparation, placement and compaction of the bedding, fill and backfill materials within the Power Block, ESWS and UHS Excavation limits.

2.0 SCOPE This procedure covers the selection, preparation, placement and compaction of bedding, fill and backfill materials in all locations at the Callaway Plant within the Power Block, ESWS and UHS Excavation limits.

-END OF SECTION-Page 4 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 3.0 RESPONSIBILITIES 3.1.

Engineering Establishes and maintains the grades for all areas ensuring that they slope away from the Power Block, Essential Service Water System (ESWS) and the Ultimate Heat Sink (UHS)

Structures or components until final acceptance of the work.

3.2.

Performing Work Group 3.2.1.

Complies with all State, Federal and OSHA Regulations pertaining to fill and backfill operations, including nuclear testing methods.

3.2.2.

Ensures work performed is in conformity with the lines, grades, typical sections and dimensions, including tolerances, either shown on the drawings or indicated in reference specifications.

3.2.3.

When Power Block fill and backfill operations include the use and placement of material described in Section 4.2, Material Designations and Requirements, ensures materials used are obtained from approved.sources and be free of stumps, frozen soil, vegetation, rubbish, contamination from other sources and objectionable matter.

3.2.4.

Ensures areas designated to.receive Power Block fill and backfill are shown on drawings or as provided by Specification 4645-4B(Q), Section 2A, Protection of the Graydon Chert Conglomerate.

3.2.5.

Removes unsuitable materials, encountered at or below the design grade, such as soft and soaked earth, vegetation, debris and organic and objectionable matter.

3.2.6.

Ensures all work is in accordance with the Current Edition of the "Missouri Standard Specifications for Highway Construction'.', which shall form a part of these specifications (referenced) to hereafter as the Standard Specifications. Also ensures that modifications and/or additional requirements from the referenced Specifications or contract drawings are adhered to.

3.2.7.

Ensures Specification 4645-30A(Q), Final Grading & Drainage Elevation Control, governs where-there are conflicts between Standard Specifications, this specification, or Specification 4645-4A(Q), Power Block Fill and Backfill.

Page 5 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 3.2.8.

Ensures compaction of fills, embankments and cut areas conform to applicable requirements of subsection 203.3 of Standard Specification with the following exceptions:

NOTE Additional "Q" placement area exist around the UHS Retention Pond, beginning at the top of slope proceeding outward fifty (50) feet.

a.

Within the Power Block "Q" Areas bounded by Plant Coordinates N99,535; N 100,615; E99,670 and E 100,139 the compaction requirements are at least 90 percent of maximum density as determined by ASTM D1557, Method A AND the moisture content of the material at the time of compaction cannot exceed 5 percentage points from the optimum moisture content as determined by ASTM D1557, Method A.

b.

Outside the limits of the Power Block Areas as defined in previous step, the compaction requirements are at least 85 percent of maximum density as determined by ASTM D1557.

c.

The backfill required for small trenches approximately six (6) inches wide and two (2) feet deep as well as other areas too restrictive for normal compaction procedures are compacted either by a mechanical roller or by hand compaction to the satisfaction of QC by visual inspection.

d.

An area around the Outage Maintenance Facility (OMF) was excluded by RFR 09993, Rev. A, from "Q" excavation and backfill requirements. The area is defined within the following boundary: Beginning at a point located N100262.00, E99730.00 thus plant north to a point N100700.00, E99730.00 thus plant west to a point N100700.00, E99450.00 thus plant south to a point N100340.00, E99450.00 thus plant east to a point N100340.00, E99520.00 thus plant south to a point N100262.00, E99520.00 thus plant east to a point N100262.00, E99730.00 the point of beginning. Refer to the RFR to view an attachment showing this area and to review requirements and options within the defined boundary.

e.

Areas brought to Final Grade and accepted may be reworked due to construction activities.

  • If the area is larger than 100 sq. ft. AND the compacted depth is six (6) inches or more, compaction test are required.

" Any cohesive materials placed under permanent roads require a compaction test.

Page 6 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 3.3.

Supervisor, Quality Control Performs quality inspections and tests on various types of soils and aggregate materials.

3.4.

Person Supervising Field Work 3.4.1.

Verifies work performed is in conformity with the lines, grades, typical sections and dimensions, including tolerances, either shown on the drawings or indicated in referenced specifications/work authorizing documents.

3.4.2.

Ensures all materials required in accordance with work authorizing document are free of stumps, frozen soil, vegetation, rubbish and other objectionable matter during preparation and placement.

3.4.3.

Ensures all areas to be filled or backfilled are free of construction debris, loose or decayable matter and standing water or free ice and snow on the surface.

3.4.4.

Ensures, when applicable, Category I Granular Structural Fill or Backfill is placed over frozen, placed, and compacted Category I Granular Structural Fill or Backfill, but NOT over frozen clay subgrade.

3.4.5.

Ensures Category I Cohesive Fill is NEVER placed over frozen clay subgrade or over frozen, placed, and compacted Category I Cohesive Fill.

3.4.6.

Ensures water for compaction purposes meets the following criteria:

a.

Is applied with suitable sprinkling devices and is thoroughly and uniformly incorporated into the material to be compacted.

b.

Compaction proceeds as soon as practicable after sprinkling process.

c.

Excessive amounts of water, as determined by QC, is NOT applied while compacting granular materials, which include Category I Granular Structural Fill, Backfill and Crushed Stone.

3.4.7.

Ensures excavation, fill, embankment areas and adjacent transition areas are uniformly smooth grades.

3.4.8.

Ensures finished surface is reasonably smooth, compacted and free from irregular surface changes.

3.4.9.

Ensures the degree of finish is that ordinarily obtainable from blade-grader operation, except as otherwise specified by these specifications.

3.4.10.

Ensures ditches are finished to permit adequate drainage.

3.4.11.

Ensures surface of areas to be seeded are finished to smoothness suitable for the preparation of the seed beds.

Page 7 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 3.4.12.

Ensures surface of embankment or excavated areas for road construction or other areas on which surfacing material is to be placed can NOT vary more than 0.10 foot from the final grade or elevation.

3.4.13.-

Ensures area surfaces within area bounded by Plant Coordinates N99,535; N100,615; E99,670 and E100,139 are finished NOT more than 0.15 foot above or below the final grade elevation.

3.4.14.

Ensures area surfaces outside of the area described in the previous step are finished NOT more than 0.5 foot above or below the final grade elevation.

3.5.

Work Group Supervisor 3.5.1.

Ensures testing is performed by Quality Control or an approved commercial testing laboratory.

3.5.2.

Ensures field density tests are in accordance with subsection 203.3 of the Standard Specifications.

3.5.3.

Ensures test results are documented in the Work Authorizing Document completion notes.

3.5.4.

When test results indicate that the compaction is NOT as specified, ensures material is removed and replaced or recompacted to meet specification requirements.

3.5.5.

Ensures subsequent tests of recompacted areas are performed to determine conformance with specification requirements.

-END OF SECTION-Page 8 of 24 INFORMATION USE Page 8 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.0 PROCEDURE INSTRUCTIONS 4.1.

Generic Information 4.1.1.

Limits of Elevation Control The limits for elevation control of finished grades in the horizontal plane are indicated on drawings and identified as the Limits of Quality Control.

The limits for elevation control of finished grades in the vertical plane are indicated on drawings and identified as Final Grades and Elevations.

4.1.2.

Overflow Points CHECK by survey, all elevations at Probable Maximum Precipitation (PMP) overflow points on roads and former railroad embankments.

PMP overflow points are shown on the PMP Drainage Plan of the Final Grading and Drainage drawings.

4.1.3.

Protection PROTECT all newly graded areas from traffic and erosion until accepted.

4.1.4.

Temporary Bracing

a.

WHEN temporary bracing of foundation walls for fill and backfill operation is needed, PERMIT ONLY after obtaining written permission from Nuclear Engineering.

b.

Do NOT place fill and backfill near temporary bracing of foundation walls, prior to written permission which will state the conditions and provisions for placing of fill and backfill.

-END OF SECTION-Page 9 of 24 INFORMATION USE Page 9 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 NOTE For material designations and requirements for ESW underground ASME Section III HDPE piping, Refer To Specification S-1080 Rev. 001, The Installation of Replacement ASME Section III Buried Essential Service Water System Piping, Section 5.0.

4.2.

Material Designations and Requirements 4.2.1.

Categorv I Granular Structural Fill

a.

MANUFACTURE Category I Granular Structural Fill from one of the following sources:

  • Callaway Limestone Formation obtained from Mertens, Inc. Reform MO.

quarry approximately five (5) miles north of the site

  • Portion of the Auxvasse Quarry approved as a source of concrete aggregate.
b.

Do NOT include or add organic matter and material above or below the Callaway Limestone Formation.

c.

ENSURE the Category I Granular Structural Fill meets the following gradation limits:

Allowable Range

(% Passing) 2 in. (50 mm) 100 1-1/2 in. (37.5 mm) 90 - 100 1 in. (25.0 mm) 80 - 100 3/4 in (19.0 mm) 70-93 3/8 in. (9.5 mm) 50 - 73 No. 4 (4.75 mm) 35 - 55 No. 10 (2.0 mm) 19 - 37 No. 30 (600 micron) 10 - 23 No. 40 (425 micron) 7 - 20 No. 200 (75 micron) 0 - 10*

  • The portion passing the No. 200 sieve cannot exceed 60 percent of the portion passing the No. 30 sieve.

Page 10 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.2.2.

Category I Granular Structural Backfill ENSURE Category I Granular Structural Backfill meets one of the following requirements:

Is of the same material and the same gradation limit as specified in Section 4.2.1, Category I Granular Structural Fill.

OR As specified in Specification 4645-4A(Q), Power Block Fill and Backfill.

4.2.3.

Category I Cohesive Fill

a.

ENSURE Category I Cohesive Fill is modified loess obtained from on site excavation or an approved alternate source.

b.

QC - VERIFY acceptability of material.

c.

IF desired, TREAT material with hydrated lime to facilitate placement and compaction.

d.

Nuclear Engineering - WHEN requested by QC or Responsible Engineer, ESTABLISH criteria for lime treatment to meet field conditions.

4.2.4.

Stabilized Backfill

a.

ENSURE Stabilized Backfill consists of granular material stabilized with Portland cement to produce a minimum 28 day unconfined compressive strength (as determined by ASTM C39) of 1000 pounds per square inch (psi).

b.

Vendor for Stabilized Backfill - PRIOR to start of work, PROVIDE mix design.

c.

WHEN approved in writing by Nuclear Engineering, USE Stabilized Backfill in lieu of Category I Granular Structural Fill and Backfill where mechanical compaction of these granular materials are impractical.

4.2.5.

Clay Blanket

a.

USE a Clay Blanket as a Non-Q impervious seal over Category I Granular Structural Fill and Backfill as shown on the drawings or as directed by Nuclear Engineering.

b.

ENSURE Clay Blankets is of the same material as specified in Section 4.2.3, Category I Cohesive Fill.

c.

IF desired, SUBSTITUTE six (6) in. (min) of concrete or asphalt in lieu of a two (2) ft. clay blanket.

Page I I of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.2.6.

Category I Bedding Material - Sand, (See CAR 200704068)

a.

ENSURE Category I Bedding Material is clean, dredged Missouri River Sand.

b.

ENSURE Category I Bedding Material is in accordance with ASTM C136 and meets the following gradation limits:

Allowable Range

(% Passing) 3/8 in 100

°No. 4 95-100 No. 8 80-100 No. 16 50-85 No. 30 14-45 No. 50 0-17 No. 100 0-5 4.2.7.

Alternate Category I Bedding Material - Aggregate Fines (See CAR 200704068)

a.

IF desired, in lieu of Category 1 Bedding Material described in Section 4.2.6, USE aggregate fines obtained from the Callaway Limestone Formation meeting the following gradation limits.

Allowable Range

(% Passing) 3/8 in 100 No. 4 90-100 No. 8 50-85 No. 16 25-50 No. 30 10-35 No. 50 5-30 No. 100 0-25

b.

IF using aggregate fines in lieu of Category 1 Bedding Material, ENFORCE the following additional stipulations (besides the gradation requirements):

1. WHEN possible, MAINTAIN the same bedding material throughout the project.
2. IF the bedding material must be changed from sand to fines or fines to sand, ENSURE the following requirements are met.

Prior to use, Nuclear Engineering approves the bedding material in writing.

Bedding material is NOT mixed in trench cross section.

-END OF SECTION-Page 12 of24 INFORMATION USE Page 12 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.3.

Installation of Category I Granular Structural Fill 4.3.1.

Preparation (prior to placement)

a.

PRIOR to requesting an inspection, REMOVE any construction debris, vegetation, water, ice or snow.

b.

WHEN area is cleaned, NOTIFY QC.

c.

ENSURE that any previously disturbed materials are recompacted and accepted by QC.

d.

ENSURE that any sieve testing for gradation requirements has been performed on material and accepted.

4.3.2.

Placement (in process)

a.

START at respective lowest elevations, PLACE and COMPACT designated fill and backfill materials, in lifts.

b.

PRIOR to starting next lift, LEVEL, SMOOTH, and properly COMPACT as specified, each lift.

c.

PLACE the surface of each lift approximately horizontal in coordination with the planned construction and drainage conditions.

d.

PLACE the first two (2) foot of Category I Granular Structural Fill above the Graydon Chert Conglomerate (GCC) surface in uniform lifts of twelve (12) inches loose thickness and compacted to a minimum dry density of 134.3 pounds per cubic foot (pcf).

e.

PLACE the remainder of the Category I Granular Structural Fill above this two (2) foot region in uniform lifts of nine (9) inches loose thickness and compacted to a minimum dry density of 138.7 pcf.

f.

IF it can be demonstrated to the satisfaction of QC that proper compaction can be obtained, INCREASE the nine (9) inch thickness of lifts to twelve (12) inches, if desired.

g.

PRIOR to continuing backfilling, ENSURE lifts during installation are inspected and accepted accordingly.

h.

ENSURE that material is placed and spread in such a manner that segregation is minimized.

4.3.3.

Post-Placement (after placement)

ENSURE compaction requirements have been achieved and accepted by QC.

-END OF SECTION-Page 13 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.4.

Installation of Category I Granular Structural Backfill 4.4.1.

Preparation (prior to placement)

CHECK the requirements stipulated in the following list of steps have been reviewed, inspected, and approved:

Step 4.3.1.a Step 4.3.1.b Step 4.3.1.c Step 4.3.2.g 4.4.2.

Placement (in process)

a.

START at respective lowest elevations, PLACE and COMPACT designated backfill materials, in lifts.

b.

PRIOR to starting next lift, LEVEL, SMOOTH, and properly COMPACT as specified, each lift.

c.

PLACE the surface of each lift approximately horizontal in coordination with the planned construction and drainage conditions.

d.

DEPOSIT Category I Granular Structural Backfill in uniform lifts of nine (9) inches maximum loose thickness and compacted to a minimum dry density of 131.4 pcf.

e.

IF it can be demonstrated to the satisfaction of QC that proper compaction can be obtained, INCREASE thenine (9) inch thickness of lifts to twelve (12) inches maximum loose thickness, if desired.

f.

PRIOR to continuing backfilling, ENSURE lifts during installation are inspected and accepted accordingly.

g.

ENSURE that material is placed and spread in such a manner that segregation is minimized.

4.4.3.

Post Placement (after placement)

ENSURE compaction requirements have been achieved and accepted by QC.

-END OF SECTION-Page 14 of 24 INFORMATION USE Page 14 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.5.

Installation of Category I Cohesive Fill 4.5.1.

Preparation (in-process)

a.

CHECK the requirements stipulated in the following list of steps have been reviewed, inspected, and approved:

  • Step 4.3.1.a
  • Step 4.3.1.b Step 4.3.1.c
b.

CHECK that moisture/density relationship test was performed and accepted.

c.

CHECK that excavated area is to design grade or as required by work authorizing document.

4.5.2.

Placement (in-process)

a.

IF using Category I Cohesive Fill,- PERFORM the following:

1. PLACE in uniform lifts of six (6) inches maximum loose thickness and compacted to a minimum dry density of 90 percent of maximum dry density as determined by ASTM D1557, Method A.
2. ENSURE the moisture content of material at time of compaction does NOT exceed five (5) percentage points from optimum moisture content.
3. IF it can be demonstrated to the satisfaction of QC that proper compaction can be obtained, INCREASE the six (6) inch thickness of lifts to nine (9) inches, if desired.

CAUTION Category I Granular Structural Backfill may ONLY be substituted for Category I Cohesive Fill

~when approved in writing by Nuclear Engineering.

b.

IF substituting Category I Granular Structural Backfill for Category I Cohesive Fill, PERFORM the following:

1. PRIOR to starting, ENSURE approval in writing from Nuclear Engineering has been obtained.
2. PLACE and COMPACT substitute material in accordance with Steps 4.4.2.d and 4.4.2.e.

Page 15 of24 INFORMATION USE Page 15 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 Step 4.5.2.b Cont'd

3. PLACE substitute material to an elevation two (2) feet below the finished elevation shown on the drawings.
4. SEAL substitute material on top with a minimum two (2) feet thick clay blanket, OR six (6) inches (min.) of concrete or asphalt pavement.
c.

PRIOR to continuing installation, ENSURE that lifts during installation are inspected and accepted.

4.5.3.

Post-Placement (after placement)

ENSURE compaction requirements have been achieved and accepted by QC.

-END OF SECTION-Page 16 of 24 INFORMATION USE Page 16 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.6.

Installation of Stabilized Backfill 4.6.1.

Preparation (pre-pour)

CHECK the requirements stipulated in the following list of steps have been reviewed, inspected, and approved:

Step 4.3.1.a Step 4.3.1.b Step 4.3.1.c Step 4.3.2.g 4.6.2.

Placement (in-process)

a.

PLACE stabilized backfill in a manner to achieve uniform consistency and maintain a near horizontal surface.

b.

Do NOT drag material more than ten (10) feet on the ground during spreading.

c.

Do NOT leave pot-holes, gaps or traffic marks in the finished surface of the placed Stabilized Backfill.

d.

WHEN a gross thickness exceeding two (2) feet is anticipated to be placed over more than fifty (50) percent of the area below any Category I structure.

PROVIDE notification to the Responsible Engineer in written form with dimensions (within 6 inches accuracy) prior to proceeding with placement of Stabilized Backfill.

e.

NOTIFY QC to ENSURE sample tests of first load each day is taken and additional tests for each 100 cubic yards thereafter.

4.6.3.

Post-Placement (after placement):

a.

CHECK finished elevation is acceptable.

b.

Do NOT permit construction equipment or construction traffic on newly placed Stabilized Backfill until material has attained sufficient strength to avoid damage by the traffic.

c.

IF QC determines damage has occurred to Stabilized Backfill, REPAIR or REPLACE as directed.

-END OF SECTION-Page 17 of 24 INFORMATION USE Page 17 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 NOTE For installation requirements for ESW underground ASME Section III HDPE piping, Refer To Specification S-1080 Rev. 001, The Installation of Replacement ASME Section III Buried Essential Service Water System Piping, Section 9.0.

4.7.

Installation of Category I Bedding Material - Sand, (See CAR 200704068) 4.7.1.

Preparation (prior to placement)

CHECK the requirements stipulated in the following list of steps have been reviewed, inspected, and approved:

Step 4.3.1.a Step 4.3.1.b Step 4.3.1.c Step 4.3.2.g 4.7.2.

Placement (in-process)

a.

PROVIDE a minimum of six (6) inches below and six (6) inches above all ESWS piping and ductbanks.

b.

PLACE Category I Bedding Material in uniform lifts of eight (8) inches maximum loose thickness and compact to minimum 70 percent relative density plus one pound per cubic foot as determined by ASTM D4253 (Replaced ASTM D2049).

c.

IF it can be demonstrated to the satisfaction of QC that proper compaction can be obtained, INCREASE the eight (8) inch thickness of lifts to twelve (12) inches, if desired.

d.

PRIOR to continuing installation, ENSURE that lifts during installation are inspected and accepted.

4.7.3.

Post-Placement (after placement)

ENSURE compaction requirements have been achieved and accepted by QC.

-END OF SECTION-Page 18 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.8.

Installation of Category I Bedding Material - Aggregate Fines, (See CAR 200704068) 4.8.1.

Preparation (prior to placement)

CHECK the requirements stipulated in the following list of steps have been reviewed, inspected, and approved:

Step 4.3.1.a Step 4.3.1.b Step 4.3.1.c Step 4.3.2.g 4.8.2.

Placement (in-process)

a.

PROVIDE a minimum of six (6) inches below and six (6) inches above all ESWS piping and ductbanks.

b.

PLACE Aggregate Fines in uniform lifts of eight (8) inches loose thickness and compact to a minimum dry density of 124.5 pcf.

c.

IF it can be demonstrated to the satisfaction of QC that proper compaction can be obtained, INCREASE the eight (8) inch thickness of lifts to twelve (12) inches, if desired.

d.

PRIOR to continuing installation, ENSURE that lifts during installation are inspected and accepted.

4.8.3.

Post-placement (after placement)

ENSURE compaction requirements have been achieved and accepted by QC.

-END OF SECTION-Page 19 of24 INFORMATION USE Page 19 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 4.9.

Installation of Clay Blanket 4.9.1.

PREPARE, PLACE, and COMPACT a Clay Blanket to Commercial Standards as directed by Nuclear Engineering Department.

4.9.2.

Nuclear Engineering Department - PERFORM a visual inspection to meet acceptance criteria.

-END OF SECTION-Page 20 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004

5.0 REFERENCES

5.1.

Implementing 5.1.1.

Specification 4645-4A(Q), Power Block Fill and Backfill 5.1.2.

Specification 4645-4B(Q), Section 2A, Protection of the Graydon Chert Conglomerate 5.1.3.

Specification 4645-4C(Q), UHS Area Fill & Backfill 5.1.4.

Specification 4645-30A(Q), Final Grading & Drainage Elevation Control 5.1.5.

FSAR 2.4 5.1.6.

FSAR 2.5 5.1.7.

FSAR 3.8 5.1.8.

OQCM, Operational Quality Control Manual 5.1.9.

CAR 200704068 5.1.10.

Specification S-1080 Rev. 001, The Installation of Replacement ASME Section III Buried Essential Service Water System Piping 5.2.

Developmental 5.2.1.

Specification, 4645-1B, Site Grading Powerblock and UHS Area Excavation Sections 2B and 2C 5.2.2.

Specification, 4645-4C(Q), Ultimate Heat Sink (UHS) Area Fill and Backfill 5.2.3.

Specification, 4645-30B,,Final Grading & Drainage 5.2.4.

Specification, 4645-32A(Q), Excavation and Backfill for Essential Service Water Systems (ESWS) Piping and Ductbanks 5.2.5.

Specification, 4645-40A, Ultimate Heat Sink Area Excavation 5.2.6.

RFR-09993A, Backfill Requirements for the OMF 5.2.7.

RFR-13860A, Clay Blanket Classification & Backfill Requirements 5.2.8.

Missouri Standard Specifications for Highway Construction 5.2.9.

ASTM C39 Standard Test Methods for Compressive Strength of Cylindrical Concrete Specimens Page 21 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 5.2.10.

ASTM D1557 Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort 5.2.11.

ASTM D4253 Standard Test Methods for Maximum Index Density and Unit Weights of Soils Using a Vibratory Table 5.2.12.

QCP-ZZ-07101, Soils Testing Procedure 5.2.13.

QCP-ZZ-07204, Inspection of Concrete, Grout, and Drypack Operations 5.2.14.

QCP-ZZ-07205, Destructive Testing Procedure 6.0 RECORDS None 7.0 DEFINITIONS None 8.0

SUMMARY

OF CHANGES Page(s)

Section or Step Number Description Changes listed below are per Engineering markups based upon CAR 200809195. Additional minor corrections/changes are IAW Procedure Writing Manual (PWM).

10 4.2 Added Note prior to Step 4.2 for material designations and requirements for ESW underground ASME Section III piping to refer to S-1080 Rev. 001.

18 4.7 Added Note prior to Step 4.7 for installation requirements for ESW underground ASME Section III piping to refer to S-1080 Rev. 001.

21 5.1.10 Added specification S-1080 Rev. 001 to Implementing References.

Page 22 of 24 INFORMATION USE Page 22 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 Drawing Lists Sheet 1 of 2 Power Block, UHS, ESWS Fill and Backfill Power Block EDP-ZZ-02002 Rev. 004

1. Title Sheet, Power Block
2. Typical Sections and Summary of Quantities, Power Block
3. Detail Sheet, Power Block
4. Detail Sheet, Power Block
5. Plani Sheet, Power Block.......
5. PlanS Shection, Power Block.........
6. Cross Sections, Power Block
7. Cross Sections, Power Block
9. Cross Sections, Power Block
10. Cross Sections, Power Block
11. Cross Sections, Power Block
12. Cross Sections, Power Block
13. Cross Sections, Power Block
14. Cross Sections, Power Block Drawing No.

8600-X-88126 8600-X-88127(Q) 8600-X-88128(Q) 8600-X-88129(Q) 8600-X-88130(Q) 8600-X-88131(Q) 8600-X-88132(Q) 8600-X-88133(Q) 8600-X-88134(Q) 8600-X-88135(Q) 8600-X-88136(Q) 8600-X-88139(Q) 8600-X-88140(Q) 8600-X-89605(Q)

Drawing No.

8600-X-88273 8600-X-88274 8600-X-88275 8600-X-88276 8600-X-88277 UHS Area 1.

2.

3.

4.

5.

Title Sheet, Ultimate Heat Sink Area Typical Sections and Summary of Quantities, Ultimate Heat Sink Area Plan Sheet, Ultimate Heat Sink Area Cross Sections, Ultim ate Heat Sink Area Cross Sections, Ultimate Heat Sink Area ESWS Piping and Ductbanks 1.

2.

3.

4.

5.

6.

Title Sheet Section Section and Details Yard Location Elevations Elevation & Summary of Quantities Drawing No.

8600-X-88376 8600-X-88377 8600-X-88378 8600-X-88379 8600-X-88380 8600-X-88381 Page 23 of 24 INFORMATION USE Page 23 of 24 INFORMATION USE

EDP-ZZ-02002 Rev. 004 (Cont'd.)

Sheet 2 of 2 Final Grade and Drainage Property-Grading Drawing No.

1. Title Sheet, Final Grading and Drainage
2. Typical Section, Final Grading and Drainage
3. Details, General Notes, Symbols, Summary of Quantities, Final Grading and Drainage
4. Summary of Quantities, Final Grading and Drainage
5. Alignment Sheet, Final Grading and Drainage
6. Key Plan, Final Grading and Drainage
7. Power Block Area, Final Grading and Drainage.-
8. Ultimate Heat Sink Area, Final Grading and Drainage
9. Cooling Tower No. 1 Area, Final Grading and Drainage
10. Cooling Tower Area, Final Grading and Drainage
11. Switchyard Area-East, Final Grading and Drainage
12. Construction Plant Area, Final Grading and Drainage
13. Road Profiles, Final Grading and Drainage
14. Road Profiles, Final Grading and Drainage
15. Railroad and Road Profiles, Final Grading and Drainage
16. P.M.P. Drainage Plan, Final Grading and Drainage
17. Downspout and Storm Drain Plan, Final Grading and Drainage
18. Downspout Drain Elevations, Final Grading and Drainage
19. Downspout Drain Elevations and Details, Final Grading and Drainage
20. Erosion Control, Final Grading and Drainage 8600-X-88285 8600-X-88286 8600-X-88287 8600-X-88288 8600-X-88289 8600-X-88290 8600-X-88291 (Q)(UNO) 8600-X-88292(Q)(UNO) 8600-X-88293(Q)(UNO) 8600-X-88294(Q)(UNO) 8600-X-88295(Q)(UNO) 8600-X-88296(Q)(UNO) 8600-X-88297(Q) 8600-X-88298(Q) 8600-X-88299(Q) 8600-X-88300(Q) 8600-X-88301 8600-X-88302 8600-X-88303 8600-X-88304 Page 24 of 24 INFORMATION USE

ATTACHMENT B

wAmerenUF Callaway Plant EDP-ZZ-01136 GROUND WATER PROTECTION PROGRAM Revision 000 Page 1 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 GROUND WATER PROTECTION PROGRAM TABLE OF CONTENTS Section Page Number 1.0 PU RPO SE...........................................................................................................................................

3 2.0 SCO PE................................................................................................................................................

3 3.0 RESPO NSIBILITIES........................................................................................................................

4 4.0 PRO CED URE INSTRU CTIO NS.................................................................................................

6 4.1.

M onitoring Program Description........................................................................................

6 4.1.1. Callaway Site Hydrology M odel.............................................................................

6 4.1.2. Risk Assessment of Systems, Structures and Components (SSC).............................. 6 4.1.3. Trending and M onitoring.......................................................................................

7 4.1.4. Rem ediation Process..............................................................................................

7 4.1.5. D ecom mission Record Keeping..............................................................................

8 4.2.

Ground W ater M onitoring W ells.......................................................................................

8 4.3.

Com m unication with N RC, State and Local Officials.....................................................

....... 9 4.3.1. V oluntary Com m unication......................................................................................

9 4.3.2. State Offi cials Briefing..............................................................................................

11 4.3.3. Reporting Requirem ents........................................................................................

12 4.4.

GPI Program A ssessm ents................................................................................................

13 4.4.1. Self A ssessm ent.....................................................................................................

13 4.4.2. NEI A ssessm ent.....................................................................................................

13 5.0 REFEREN CES.................................................................................................................................

14 5.1.

Im plem enting........................................................................................................................

14 5.2.

D evelopm ental......................................................................................................................

14 6.0 RECORDS.......

15 6.1.

QA Record............................................................................................................................

15 6.2.

Com m ercial Record...............................................................................................................

15 7.0 DEFIN ITIO N S..................................................................................................................................

15 8.0 SUM M A RY O F CH AN G ES...........................................................................................................

17 ATTACHMENT 1, Map of Ground Water Monitoring Wells 18 ATTACHMENT 2, Communication Protocol for Leak/Spill and Ground Water Sample Results (N EI 07-07)........................................................................................................................................

19 Page 2 of 19 INFORMATION USE

EDP-ZZ-01136 Rev. 000 GROUND WATER PROTECTION PROGRAM 1.0 PURPOSE 1.1.

Provides guidance for implementing a ground water protection program incorporating the objectives described in Industry Ground Water Protection Initiative - Final Guidance Document NEI 07-07.

1.2.

Ensures timely detection and effective response to inadvertent radiological releases to ground water.

1.3.

Ensures the trust and confidence of state/local officials, the Nuclear Regulatory Commission (NRC), and the public by demonstrating nuclear industry's commitment to a high standard of public radiation safety and protection of the environment.

2.0 SCOPE 2.1.

Identifies actions necessary for implementation of a timely and effective ground water protection program.

2.2.

Specifies the frequency at which each program element is performed.

2.3.

Describes the reporting requirements for sample results that exceed the criteria outlined in this document.

2.4.

This program does NOT apply to:

2.4.1.

Normal or routine releases managed in accordance with HTP-ZZ-07 101, Radiological Environmental Monitoring Program (REMP) or APA-ZZ-01003, Off-Site Dose Calculation Manual (ODCM).

2.4.2.

Planned or routine releases within the scope of the approved facility design or operation as provided in Technical Specifications, Final Safety Analysis Report (FSAR), procedures or related documents.

2.4.3.

Radioactive material that is NOT licensed material, or that was NOT generated as a result of plant operations.

Page 3 of 19 INFORMATION USE Page 3 of 19 INFORMATION USE

EDP-ZZ-0 1136 Rev. 000 3.0 RESPONSIBILITIES 3.1.

Engineering 3.1.1.

Implements the Ground Water Monitoring Program.

3.1.2.

Conducts periodic reviews of site hydrogeologic studies.

a.

Maintains the ground water model up to date based on current plant conditions.

b.

Ensures the appropriate sections of the FSAR are updated with the current ground water model.

3.1.3.

Performs initial and periodic reviews on risk assessments and calculation(s) of Priority Index (PI) for SSCs expected to contain licensed radioactive material that could impact ground water.

3.1.4.

Notifies Regulatory Affairs regarding any informal communications to NRC or state/local officials.

3.1.5.

Monitors and improves the Preventive Maintenance (PM) program for ground water monitoring wells.

3.1.6.

Performs reviews of ground water monitoring program every five years.

3.1.7.

Initiates self assessment of ground water program every five years.

3.2.

Radiation Protection (RP) 3.2.1.

Ensures sample collections and shipment of samples to the lab.

3.2.2.

Ensures samples are analyzed, reviewed and documented.

3.2.3.

Responsible for Laboratory Quality Assurance Program.

3.2.4.

Trends and monitors ground water monitoring wells.

3.2.5.

Notifies Engineering regarding any abnormal trends in samples or inadvertent leaks/spills in the plant which have a potential to reach ground water.

3.3.

Regulatory Affairs 3.3.1.

Contacts state/local officials and the NRC regarding any informal communications related to ground water.

3.3.2.

Ensures notification/reports are made in a timely manner.

3.3.3.

Initiates and submits 30-day reports to Missouri Department of Natural Resources (MO DNR), Callaway County Presiding Officer and the NRC.

Page 4 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 3.4.

Environmental Services 3.4.1.

Ensures records of leaks, spills, remediation efforts are retained and retrievable to meet the requirements of 10 CFR 50.75(g).

3.4.2.

Provides an interface with MO DNR.

-END OF SECTION-Page 5 of 19 INFORMATION USE Page 5 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 4.0 PROCEDURE INSTRUCTIONS 4.1.

Monitoring Program Description 4.1.1.

Callaway Ground Water Model

a.

UTILIZE the ground water model to IDENTIFY the following: [Ref: 5.2.8]

" Potential pathways for ground water migration from on-site to off-site locations.

  • Potential affected areas.
b.

PERFORM a review of site hydro geologic studies every five years or whenever any of the following occurs:

  • Significant onsite construction or disturbance of site property.
  • Significant changes in onsite or nearby offsite use of water.
  • Significant changes in onsite or nearby offsite pumping rates of ground water.
c.

UPDATE FSAR with changes to the characterization of hydrology and/or geology, as applicable. [Ref: 5.2.4]

4.1.2.

Risk Assessment of Systems, Structures and Components (SSC)

a.

PERFORM initial risk assessment of SSCs and work practices which contain or could contain licensed materials and ASSIGN a Priority Index (PI) based on the evaluation. [Ref: 5.2.9]

b.

RE-EVALUATE the SSCs in the event of any leaks or spills.

c.

RE-CALCULATE the Priority Index (PI) in accordance with the severity of the leaks/spills.

d.

To minimize the potential for inadvertent releases of licensed materials due to equipment failure, PERFORM a review of the SSCs evaluated as a part of this program every five years to ensure any enhancements or additional PMs or surveillances needed are included.

Page 6 of 19 INFORMATION USE Page 6 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 4.1.3.

Trending and Monitoring

1. REVIEW abnormal ground water analysis trends provided by Radiation Protection.

NOTE Sampling and analysis protocols of ground water and review of station or contract lab(s) analytical capabilities are performed by RP per HTP-ZZ-07101, Radiological Environmental Monitoring Program.

b.

CONDUCT semi-annual meetings with members from Plant Engineering, Radiation Protection and Environmental Service Departments to review the ground water monitoring program.

c.

MONITOR SSCs which have a high PI and are highly susceptible to leaks/spills which may result in ground water contamination.

4.1.4.

Remediation Process

a.

EVALUATE all leaks/spills or other instances of inadvertent releases of radioactive material in accordance with RP-DTI-ENVIRONMENTAL-SPILLRESP, Response to Spills or Leaks of Radioactive Material.

NOTE Planned releases of liquids and/or airborne materials from the plant are NOT considered LICENSED MATERIALS when returned to the plant as long as the concentration of the radioactive material does NOT exceed 10 CFR Part 30 "Rules of general applicability to Domestic Licensing to By-product material". [Ref: 5.2.7]

b.

RECORD all documents related to decommissioning impacts resulting from spills or leaks and remediation in accordance with APA-ZZ-00500, Corrective Action Program, with the following keywords:

  • DECOMMISSION Page 7 of 19 INFORMATION USE Page 7 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 4.1.5.

Decommission Record Keeping APA-ZZ-00221, Reporting and Recordkeeping for Decommissioning Planning, provides reporting and recordkeeping requirements for decommission planning in accordance with 10 CFR 50.75(g).

4.2.

Ground Water Monitoring Wells NOTE HTP-ZZ-07 101 Appendix A, REMP Sample Locations, Attachment 4, provides the list of all ground water monitoring wells that Callaway samples. Attachment 1 shows the map of all the ground water monitoring wells.

4.2.1.

Based on hydrology and highest priority SSCs, DETERMINE appropriate placement of ground water monitoring wells.

a.

LABEL ground water monitor wells with a unique identifier.

b.

ENSURE all ground water monitoring wells are sampled per HTP-ZZ-07101, Radiological Environmental Monitoring Program.

c.

ENSURE the well maintenance vendor(s) perform the following:

1. ENSURE well preventive maintenance and repairs are performed by qualified or knowledgeable personnel in accordance with state and industry standards.
2. PERFORM a visual inspection to the following and ENSURE the structural integrity of the well casing, seals and well cap is maintained to prevent surface water and contaminants from entering the well:

a Cracked or corroded well casing Broken or missing well cap or lock

  • Damage to protective casing
  • Settling and cracking of surface seals
3. ENSURE the wells are properly labeled.
4. DOCUMENT any well abnormalities in accordance with APA-ZZ-00500, Corrective Action Program.
5. ENSURE inspection and maintenance records are properly maintained.
6. ENSURE wells which are no longer used for their intended purpose are decommissioned or abandoned in accordance with state regulations.

Page 8 of 19 INFORMATION USE

EDP-ZZ-01136 Rev. 000 4.3.

Communication with NRC, State and Local Officials 4.3.1.

Voluntary Communication

a.

REVIEW Attachment 2 to determine the communication protocol as it applies to leaks, spills or ground water sample results.

b.

ENSURE Regulatory Affairs communicates with the following authorities regarding any onsite leak or spill into ground water as required by, OR any onsite or offsite water sample results exceeding the limits of HTP-ZZ-07101, Radiological Environmental Monitoring Program, in accordance with APA-ZZ-00520, Reporting Requirements and Responsibilities:

1. Missouri Department of Natural Resources (MO DNR)
2. Callaway County Presiding Commissioner
3. NRC Resident Inspector
4. NRC Region WV Office
c.

COMMUNICATE with designated state or local authorities before the end of the next business day IF an inadvertent leak or spill to the environment has occurred which can potentially get into the ground water and satisfies any of the following conditions:

1. Exceeds or likely to exceed 100 gallons from a source containing LICENSED MATERIAL.
2. Regulatory Affairsdetermines a voluntary communication is necessary regardless of volume or activity from spills/leaks.

Page 9 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 Step 4.3.1 Cont'd NOTE "Leak or spill" events that meet the criteria shall be communicated regardless of whether or NOT the on-site ground water is, or could be used as, a source of drinking water.

d.

COMMUNICATE with designated state/local officials before the end of the next business day for a water sample result:

1. Of off-site ground water or surface water that exceeds any of the REMP reporting criteria for water as described in the ODCM or NOTE The basis for concluding the on-site ground water is not or would not be considered a source of drinking water will depend on the hydrological data of that area. In the absence of adequate hydrological data, any leak / spill into ground water which exceeds the reporting levels of FSAR-SP Table 16.11-8, must be assumed to be a potential contaminant of drinking water and must be communicated as per Step 4.3.1.d.2 and also reported pursuant to Step 4.3.3.a. 1.
2. Of on-site surface water, hydrologically connected to ground water, or ground water used or could be used as a source of drinking water, and exceeds any of the REMP reporting criteria for water as described in the ODCM/ODAM.
e.

PROVIDE the following information regarding a spill or leak WHEN communicating with the Missouri Department of Natural Resources (MO DNR) or local officials, and the NRC and DOCUMENT each event in a CAR in accordance with APA-ZZ-00500, Corrective Action Program:

1. A statement that the communication is being made as part of the NEI Ground Water Protection Initiative.
2. Date and time of spill, leak, or sample result(s).
3. Whether or NOT spill has been contained or leak has been stopped.
4. Location of leak or spill or water sample(s), IF known.
5. Source of leak or spill, IF known.
6. List of contaminant(s) and verified concentration(s).

Page 10 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 Step 4.3.1.e Cont'd

7. Description of action(s) already taken and general description of future actions.
8. Estimate of potential or bounding annual dose to a member of the public, IF available at this time.
9. Estimated time/date to provide additional information or follow-up.
f.

NOTIFY the NRC regarding voluntary communication to state and/or local officials per 10 CFR 50.72(b)(2)(xi).

g.

NOTIFY NEI by email at GW Notice@nei.org.

h.

PROVIDE a copy of each communication with MO DNR to Environmental Services - Water Quality.

4.3.2.

State Officials Briefing OFFER annual update meetings with MO DNR regarding the ground water protection program.

Page 11 of 19 INFORMATION USE Page I I of 19 INFORMATION USE

EDP-ZZ-0 1136 Rev. 000 4.3.3.

Reporting Requirements

a.

Thirty-day Reports

1. Submit a thirty-day report to the NRC for all on-site and off-site water sample results that exceed any of the REMP reporting criteria and could potentially reach the ground water used or could be used as a source of drinking water.

NOTE The initial discovery of ground water contamination greater than the REMP reporting criterion is the event documented in a written 30-day report. It is NOT expected that a written 30-day report will be generated each time a subsequent sample(s) suspected to be from the same "plume" identifies concentrations greater than any of the REMP criteria as described in the ODCM/ODAM.

2. The 30-day special report should include:
  • A statement that the report is being submitted in support of the Ground Water Protection Initiative (CPI).
  • Lit of contaminant(s) and verified concentration(s).
  • Description of the action(s) taken.
  • Estimate of potential or bounding annual dose to a member of the public.

" Corrective action(s) IF necessary, that will be taken to reduce projected annual dose to a member of the public to less than the limits in 10 CFR 50 Appendix 1.

3. Concurrently FORWARD all written 30-day NRC reports generated to MO DNR and Callaway County Presiding Commissioner.
b.

Annual Reporting

1. ENSURE all onsite and offsite ground water sample results taken in support of the GPI (also included in REMP) are documented in AREOR.
2. ENSURE all voluntary communications made to the MO DNR and local officials are included in the report with a description of the spills/leaks or sample results.

Page 12 of 19 INFORMATION USE Page 12 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 4.4.

GPI Program Assessments 4.4.1.

Self Assessment NOTE Self assessments could be an internal or external assessment but should only be performed by an independent, knowledgeable individual(s) NOT involved in the implementation of the GPI program.

a.

PERFORM an initial self assessment in accordance with APA-ZZ-01400, Performance Improvement Program, within one year of implementation of the GPI program.

b.

PERFORM periodic self-assessment of the GPI program at least once every five years after initial self-assessment.

c.

EVALUATE in the self-assessment, at a minimum, the implementation of all of the objectives identified in this document.

d.

ENSURE the self-assessment is documented in accordance with APA-ZZ-00500, Corrective Action Program, or applicable procedures or programs.

4.4.2.

NEI Assessment

a.

CONDUCT a review of the GPI program under the auspices of NEI within one year from the initial self assessment as per Step 4.4.1.a.

b.

ENSURE a review of the GPI program is performed every five years, subsequent to Callaway's periodic self-assessment performed as per Step 4.4.1.b.

Page 13 of 19 INFORMATION USE Page 13 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000

5.0 REFERENCES

5.1.

Implementing 5.1.1.

10CFR50.75 (g), Reporting and Record Keeping for Decommissioning 5.1.2.

APA-ZZ-00221, Reporting and Recordkeeping for Decommissioning Planning 5.1.3.

APA-ZZ-00500, Corrective Action Program 5.1.4.

APA-ZZ-00520, Reporting Requirements and Responsibilities 5.1.5.

APA-ZZ-01003, Off-Site Dose Calculation Manual 5.1.6.

APA-ZZ-01400, Performance Improvement Program 5.1.7.

FSAR-SP Table 16.11-8 5.1.8.

HTP-ZZ-07101, Radiological Environmental Monitoring Program 5.1.9.

HTP-ZZ-07101 Appendix A, REMP Sample Locations 5.1.10.

RP-DTI-ENVIRONMENTAL-SPILLRESP, Response to Spills or Leaks of Radioactive Material 5.2.

Developmental 5.2.1.

10CSR23.4, Monitoring Well Construction Code 5.2.2.

ANI Nuclear Liability Insurance Guideline 07-01 5.2.3.

EPRI 1015118, Ground Water Protection Guidelines for Nuclear Power Plants 5.2.4.

FSAR 2.4.13 5.2.5.

NEI 07-07, Industry Ground Water Protection Initiative - Final Guidance Document 5.2.6.

NRC Information Notice 2006-13, Ground Water Contamination Due to Undetected Leakage of Radioactive Water 5.2.7.

RIS 2008-03, Return/Re-use of Previously Discharged Radioactive Effluents 5.2.8.

Ground Water Model Report for Callaway Unit 1 5.2.9.

SA08-PE-S06, Assessment of SSCs as a part of Groundwater Protection Initiative program (NEI 07-07) (I:\\NUCENG\\COMMON\\Groundwater Protection Initiative\\SSC Evaluation NEI 07-07)

. Page 14 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 6.0 RECORDS 6.1.

QA Record 6.1.1.

Annual Environmental Operating Report (E160.0608) 6.2.

Commercial Record 6.2.1.

SA08-PE-S06, Assessment of SSCs as a part of Groundwater Protection Initiative program (NEI 07-07) (G110.0031) 7.0 DEFINITIONS 7.1.

AREOR (Annual Radiological Environmental Operating Report) - summarizes the results of the REMP to the NRC.

7.2.

Ground Water - any subsurface water, whether in the unsaturated or vadose zone, or in the saturated zone of the earth.

7.3.

Informal (Communication) - a communication, typically by telephone, between licensee personnel and the state/local officials. Subsequent notification of the NRC under 10 CFR 50.72 should be performed consistent with station policy.

7.4.

Leak or Spill - The "leak or spill" represents an inadvertent event or perturbation in a system or component's performance. This event threshold is intended to ensure that state/local officials are made aware there has been an event of interest at the site and to keep them apprised of the licensee's action to contain and, as needed, remediate the event. "Leak or spill" events that meet the criteria shall be communicated regardless of whether or NOT the on-site ground water is, or could be used as, a source of drinking water.

7.5.

Licensed Material (From 1 OCFR20.1003) - source material, special nuclear material, or byproduct material received, possessed, used, transferred or disposed of under a general or specific license issued by the Commission.

7.6.

LLD - Lower Limit of Detection 7.7.

Monitoring Well - a borehole drilled in the earth and lined, either partially or entirely, with a casing to stabilize and isolate one or more sections of the borehole. They are used to collect environmental media for examination and testing. They are intended to be in service for long periods (typically years) to allow continued sampling of ground water.

7.8.

ODCM/ODAM (Offsite Dose Calculation Manual or Offsite Dose Assessment Manual) -

The licensee's manual required by Technical Specifications that contains the dose assessment methodology and radiological effluent technical specifications.

Page 15 of 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 7.9.

Potential to Reach Ground Water:

Spills or leaks with the potential to reach ground water:

e Spill or leak directly onto native soil or fill 0

Spill or leak onto an artificial surface (i.e., concrete or asphalt) IF the surface is cracked or thematerial is porous or unsealed Spill or leak that is directed into unlined or non impervious ponds or retention basins (i.e., water hydrologically connected to ground water) 7.10.

REMP (Radiological Environmental Monitoring Program) - program specified by the ODCMIODAM that provides measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides, which lead to the highest potential radiation exposures of individuals resulting from the station operation.

7.11.

RETS (Radiological Effluent Technical Specifications) - Specifications required to control the release of radioactive liquids and airborne materials from the site. Standard radiological effluent technical specifications are found in NUREG CR-1301.

7.12.

Significant (leak or spill) - an item or incident of interest to the public or stakeholders. It does NOT imply or refer to regulatory terminology nor is it intended to indicate the leak or spill has public health and safety or environmental protection consequences.

7.13.

Site Conceptual Model - A unifying hypothesis to describe how a contaminant release may be observed and measured currently in the site environment, and to identify the ultimate fate of the contaminant in the future. The model incorporates the site's hydrogeology, existing and past site activities that may have resulted in contaminant releases to the environment, location of those releases, contaminants of concern, their fate and transport within the environment, and receptors of those contaminants.

7.14.

Source Containing Licensed Material - A liquid, including steam, for which a statistically valid positive result is obtained when the sample is analyzed to the following a priori lower limits of detection (analytical sensitivity).

The analytical sensitivity for identifying a source containing licensed material is at a minimum - the licensee's lower limits of detection that are required for radioactive liquid effluents for all isotopes.

7.15.

Substantial On-Site Construction or Substantial Disturbance of Site Property -

Substantial refers to the likelihood that the construction or disturbance has affected the subsurface flow of ground water.

Page 16 of. 19 INFORMATION USE

EDP-ZZ-01 136 Rev. 000 7.16.

Surface Water - Water within streams, lakes reservoirs, discharge canals, cooling towers, retention ponds, water from precipitation events, wetlands, estuaries, and oceans.

7.17.

Vadose Zone - The subsurface zone where earth materials are NOT saturated.

7.18.

Voluntary (as used in the GPI) - NOT required by statute or regulation.

8.0

SUMMARY

OF CHANGES Section or Page(s) Step or Description Step Number All All ENew Procedure (CAR 2.00800353)

Page 17 of 19 INFORMATION USE

EDP-ZZ-0 1136 Rev. 000 Map of Ground Water Monitoring Wells Sheet 1 of 1 MW - MONITORING WELLS F06E F15 = NPDES MONITORING WELLS MONITORING WELLS OW-,2,3,4,5 = OBSERVATION WSLLS (SEE ENLARGED VEW)

UNIT 1 DEEP WELLS 1 &2 51 - DIESEL FUEL REMEDIATION WELL (SEE ENLARGED VIEW) 937A.B.CD,E,F - UNIT 1 MONITORING WELLS (SEE ENLARGED VIEW) 501,502-LANDFILL MONITORING WELLS PIEZOMETERS ME M7. FSAR-SA FiG. 2.4-30 REF: HTP-Z-07101, APPENDLX A Page 18 of 19 INFORMATION USE Page 18 of 19 INFORMATION USE

EDP-ZZ-01136 Rev. 000 Communication Protocol for Leak/Spill and Ground Water Sample Results (NEI 07-07)

Sheet 1 of I NOTE: ALL ON-SITE GROUNDWATER SAMPLE RESULTS INCLUDED IN ARERR OR AREOR Page 19 of 19 INFORMATION USE Page 19 of 19 INFORMATION USE

HTP-ZZ-07101 RADIOLOGICAL ENVIROMENTAL MONITORING PROGRAM MINOR Revision 015 Page I of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 RADIOLOGICAL ENVIROMENTAL MONITORING PROGRAM TABLE OF CONTENTS Section Page Number 1.0 PU RPO SE...........................................................................................................................................

3 2.0 SCO PE................................................................................................................................................

3 3.0 RESO N SIBILITIES..............................................................................

3 4.0 PRECAUTIONS AND LIMITATIONS.....................................................................................

3 5.0 PR EREQ U ISITES.............................................................................................................................

3 6.0 PR O CED U RE IN STR U CTIO N S.................................................................................

................ 4 6.1.

M onitoring Program........................................................................................................

4 6.1.1. Program D escription..............................................................................................

4 6.1.2. Sam ple Identification System................................................................................

5 6.2.

Tracking...................................................................................................................................

6 6.3.

Laboratory Q uality Control Program...................................................................................

7 6.3.1. Laboratory Q uality A ssurance Program..................................................................

7 6.3.2. Intralaboratory A nalysis..........................................................................................

7 6.3.3. Interlaboratory Com parison Program.....................................................................

8 6.4.

Reporting Requirem ents....................................................................................................

9 6.4.1. Annual Radiological EnvironmentalOperating Report (AREOR).......................... 9 6.4.2. 30 D ay Reports....................................................................................................

9 6.4.3. Inform al N otifications............................................................................................

10 6.5.

REM P Problem Reporting.....................................................................................................

11 7.0 REFERE N CES.................................................................................................................................

12 7.1.

Im plem enting.........................................................................................................................

12 7.2.

D evelopm ental.......................................................................................................................

12 8.0 RE CO RD S........................................................................................................................................

13 9.0 D EFIN ITIO N S.................................................................................................................................

13 10.0 SUM M A R Y O F CH A N G ES...........................................................................................................

13 ATTACHMENT 1, Communication Protocol For Leak/Spill And Groundwater Sample Results......

14 HTP-ZZ-07 101 Appendix A, REMP Locations Page 2 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 RADIOLOGICAL ENVIROMENTAL MONITORING PROGRAM 1.0 PURPOSE This procedure provides the program for implementation of the Radiological Environmental Monitoring Program (REMP) for the Callaway Plant.

2.0 SCOPE 2.1.

Provides a description of the REMP implemented to meet APA-ZZ-01003, Off-site Dose Calculation Manual, 2.2.

Establishes the process for tracking radiological environmental monitoring requirements conducted at the Callaway Plant.

2.3.

Describes the reporting requirements for sampling and spills to NRC, state and local officials.

3.0 RESONSIBILITIES None 4.0 PRECAUTIONS AND LIMITATIONS None 5.0 PREREQUISITES None

-END OF SECTION-Page 3 of 14 INFORMATION USE Page 3 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.0 PROCEDURE INSTRUCTIONS NOTE This procedure is performed by the REMP Program Owner unless noted.

6.1.

Monitoring Program 6.1.1.

Program Description

a.

Ensure sample locations for the REMP are shown and described in HTP-ZZ-07101 Appendix A, REMP Sample Locations.

b.

IF any changes to sample locations, approve the sample locations in HTP-ZZ-07 101 Appendix A, REMP Sample Locations.

c.

Ensure the sample collection frequencies for each sample type is maintained.

-END OF SECTION-Page 4 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.1.2.

Sample Identification System

a.

Ensure sample identification code for each sample type and location as

  • follows:
1. Plant Code - CA NOTE Sample media codes AQF, AQS, and FPL require additional information that further describes the sample media. For example, fish should include species (i.e., carp, flathead catfish, etc.).
2. Media Code - Three letters identifying the media being sampled is defined as follows:

MEDIA CODE AIO APT AQF AQS FPL IDM MLK SOL SWA WWA DWA FC SAMPLE TYPE Air Iodine Air Particulate Fish Sediment Leafy Green Vegetables TLD Milk Soil Surface Water Ground Water Drinking water, well Farm Crop

3.

Location Code - defined in HTP-ZZ-07101 Appendix A, REMP Sample Locations.

-END OF SECTION-Page 5 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.2.

Tracking 6.2.1.

Schedule and track the completion of the following activities:

REMP sample collection and analysis required in Attachment 1 Land Use Census Vendor Interlaboratory Comparison and Cross Check Programs REMP reportable Nuclide Evaluation Report Vendor Monthly Progress Report Annual Environmental Operating Report

-END OF SECTION-Page 6 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.3.

Laboratory Quality Control Program 6.3.1.

Laboratory Quality Assurance Program

a.

Bid specifications used for procurement of REMP radioanalytical services must contain requirements for an outside laboratory quality assurance program using the requirements in the USNRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Normal Operations)

Effluent Streams and Environment, APA-ZZ-01003, Off-site Dose Calculation Manual and FSAR-SP Chapter 16.11.4.3, Interlaboratory Comparison Program Limiting Condition at operation, as applicable.

b.

Outside laboratories that perform REMP analysis services should be audited at least triennially.

c.

Submit a CA1592, Request for Supplier Evaluation, when new laboratories are added to the program.

6.3.2.

Intralaboratory Analysis

a.

Ensure Radioanalytical laboratories conduct an acceptable Intralaboratory Comparison Program with results periodically reported in Monthly Progress Reports per USNRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Normal Operations) Effluent Streams and Environment.

b.

Ensure Primary Monitoring Device (PMD) service provider meets the requirements of USNRC Regulatory Guide 4.13, " Performance, Testing, and Procedural Specifications for Thermoluminescent Dosimetry Environmental Applications" Rev 1 and is accredited by NVLAP in accordance with ANSI N. 13.11 For Photon Mixtures And Photon/Beta Mixtures.

c.

Ensure Radioanalytical Intralaboratory Comparison Program contains the following elements:

Replicate samples, usually duplicates, are analyzed routinely. These samples are replicates of monitoring program samples and/or reference test materials. The size and composition of replicate samples are similar to samples analyzed routinely.

Spiked and blank samples are submitted for analysis as unknowns to provide a basis for estimating accuracy of analytical results. These blanks and spikes may include blind replicates.

Page 7 of 14 INFORMATION USE Page 7 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.3.3.

Interlaboratory Comparison Program

a.

Contract laboratories that provide radiological environmental monitoring radioanalytical services must be required to participate in an Interlaboratory Comparison Program, as described in FSAR-SP Chapter 16.11.4.3, Interlaboratory Comparison Program Limiting Condition at operation and APA-ZZ-01003, Off-site Dose Calculation Manual, with results periodically reported in Monthly Progress Report.

b.

Interlaboratory Comparison Program results and corrective actions taken by the outside laboratories for sample results which do NOT meet the acceptance criteria are reviewed per appropriate Callaway Plant procedures.

c.

The Interlaboratory Comparison Results and Review Comments must be incorporated into the Annual Radiological Environmental Operating Report per the APA-ZZ-01003, Off-site Dose Calculation Manual.

d.

The PMD vendor conducts an Interlaboratory Comparison Program which meets the NVLAP requirements.

-END OF SECTION-Page 8 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.4.

Reporting Requirements 6.4.1.

Annual Radiological Environmental Operating Report (AREOR)

a.

The requirements for the AREOR are described in FSAR-SP Chapter 16.11.5.1 and FSAR-SP 16.11.4.1.

b.

Submit the AREOR per requirements of APA-ZZ-00520, Reporting Requirements and Responsibilities.

c.

Document all onsite and offsite groundwater sample results.

d.

Describe all onsite leaks/ spills into groundwater as reported in Section 6.4.2.

6.4.2.

30 Day Reports

a.

Special report to the NRC are submitted within 30 days per requirements of APA-ZZ-00520, Reporting Requirements and Responsibilities for the following:

" The level of radioactivity in an environmental sampling medium resulting from plant effluents exceeds the reporting levels of FSAR-SP Table 16.11-8 when averaged over any calendar quarter.

The reporting level-weighted concentration of two or more nuclides is greater than 1.0.

  • Nuclides are detected that are not listed in FSAR-SP Table 16.11-8 and the calculated annual dose a Member of the Public from all radionuclides is equal to or greater than the limits of FSAR-SP sections 16.11.1.2, FSAR-SP sections 16.11.2.2, or FSAR-SP sections 16.11.2.3.

NOTE Residents along Mud Creek and Logan Creek take their drinking water from wells.

b.

Special report to the NRC and to the Missouri Department of Natural Resources are submitted within 30 days per requirements of APA-ZZ-00520, Reporting Requirements and Responsibilities if the level of radioactivity in onsite groundwater that is used or may be used as a source of drinking water exceeds the reporting levels as described in 6.4.2.a.

c.

In the absence of adequate hydrological data, any leak / spill into groundwater which exceeds the reporting levels of FSAR-SP Table 16.11-8, must be assumed to be a potential contaminant of drinking water and must be reported pursuant to 6.4.2.b.

Page 9 of 14 INFORMATION USE Page 9 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 Step 6.4.2 Cont'd

d.

If ground water is not currently used for drinking water but is potable, consider ground water a potential source of drinking water.

e.

All written 30 day reports generated under must be concurrently forward to the Missouri Department of Natural Resources and the Callaway County Presiding Commissioner.

6.4.3.

Informal Notifications NOTE Informal notification is made per the requirements of APA-ZZ-00520, Reporting Requirements and Responsibilities.

Informal notifications do NOT require a 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> report per 10CFR50.72

a.

Manager, Regulatory Affairs, Evaluate each spill or leak in accordance with the flowchart provided in Attachment 1.

b.

Groundwater Protection Program Owner, Notify NEI of any informal notifications pursuant to Attachment 1.

c.

Make all informal notifications by the end of the next business day.

d.

Notify the following (in this order):

1. Missouri Department of Natural Resources
2. NRC Resident Inspector
3. NRC Region IV Office

-END OF SECTION-Page 10 of 14 INFORMATION USE Page 10 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 6.5.

REMP Problem Reporting 6.5.1.

Review the REMP sample collection sheets and REMP Monthly Progress Report for any of the following:

Adverse trend in obtaining samples.

Adverse trend in sample results including an unusual increase in natural background levels.

Measurable level of a nuclide that could have been caused by operation of the plant (excluding tritium in surface water).

Unresolved problem identified in the vendor quality control or cross check programs.

The Lower Limit of Detection (LLD) required by FSAR-SP Table 16.11-9 is NOT achieved.

Radiological Environmental Monitoring Program was NOT conducted as required by APA-ZZ-01003, Off-site Dose Calculation Manual.

The level of radioactivity at a specific location exceeds the reporting level of FSAR-SP Table 16.11-8.

A milk or vegetation sample location required by APA-ZZ-01003, Off-site Dose Calculation Manual is no longer available.

The Land Use Census identifies a new location that yields a calculated dose or dose commitment 20% greater than at a location currently sampled.

6.5.2.

If any of the items above are found, or if any samples are missed, generate a CARS per APA-ZZ-00500, Corrective Action Program.

6.5.3.

At the end of the calendar year, review all REMP CARs for the year and include significant problems in the Annual Environmental Operating Report.

-END OF SECTION-Page 11 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015

7.0 REFERENCES

7.1.

Implementing 7.1.1.

APA-ZZ-00500, Corrective Action Program 7.1.2.

APA-ZZ-00520, Reporting Requirements and Responsibilities 7.1.3.

APA-ZZ-01003, Off-site Dose Calculation Manual 7.1.4.

HTP-ZZ-07101 Appendix A, REMP Sample Locations 7.1.5.

CA1592, Request for Supplier Evaluation 7.1.6.

USNRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Normal Operations) Effluent Streams and Environment 7.1.7.

USNRC Regulatory Guide 4.13, " Performance, Testing, and Procedural Specifications for Thermoluminescent Dosimetry Environmental Applications" Rev 1 7.1.8.

FSAR-SP Chapter 16.11.4.3, Interlaboratory Comparison Program Limiting Condition at operation 7.1.9.

FSAR-SP Chapter 16.11.5.1, Annual Radiological Environmental Operating Report 7.1.10.

FSAR-SP 16.11.4.1, Monitoring Program Limiting Condition of Operation 7.1.11.

FSAR-SP Table 16.11-8, Reporting g Levels for Radioactivity Concentrations in Environmental Samples 7.1.12.

FSAR-SP Table 16.11-9, Detection Capabilities for Environmental Sample Analysis 7.1.13.

FSAR-SP sections 16.11.1.2, Bases 7.1.14.

FSAR-SP sections 16.11.2.2, Dose -Noble Gases Limiting Condition for Operation 7.1.15.

FSAR-SP sections 16.11.2.3, Dose-Iodine-131 and 133, Tritium, and Radioactive Material in Particulate form Limiting Condition of Operation 7.1.16.

ANSI N.13.11 For Photon Mixtures And Photon/Beta Mixtures 7.1.17.

10CFR50.72 7.2.

Developmental EDP-ZZ-01 136, Ground Water Protection Program Page 12 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 8.0 RECORDS 8.1.1.,

REMP Monthly Progress Reports, (E160.0622) 8.1.2.

Sample Collection Data Sheet, (E160.0602) 8.1.3.

REMP Reportable Nuclide Evaluation, (E160.0604) 8.1.4.

Annual Environmental Operating Report, (E160.0608) 8.1.5.

Quarterly TLD Calculation Worksheets, (E160.0612) 8.1.6.

Land Use Census Field Study, (E160.0616) 8.1.7.

Annual Effluent Release Reports / Meteorologist's, (H240.0030) 8.1.8.

Air Sampler Calibration, (H170.0064) 9.0 DEFINITIONS Groundwater - Water located beneath the ground surface in soil pore spaces and in the fractures of geologic formations. Groundwater includes soil moisture and immobile water in very low permeability materials such as clay or bedrock. A formation of rock/soil is called an aquifer when it can yield a useable quantity of water. The depth at which soil pore spaces become saturated with water is called the water table. GrOundwater is recharged from, and eventually flows to, the surface naturally; natural discharge often occurs at springs and seeps and can form oases or wetlands.

Groundwater is naturally replenished by surface water from precipitation, streams, and rivers. Usable groundwater is contained in aquifers, which are subterranean areas (or layers) of permeable material (like sand and gravel) that channel the groundwater's flow. Aquifers can be confined or unconfined.

If a confined aquifer follows a downward grade from a recharge zone, groundwater can become pressurized as it flows. This can create artesian wells that flow freely without the need of a pump.

The top of the upper unconfined aquifer is called the water table or phreatic surface, where water pressure is equal to atmospheric pressure.

10.0

SUMMARY

OF CHANGES Page(s)

Section or Step Description Number 10 6.4.3.c, 6.4.3.d Added instructions for making notifications of APA-ZZ-00520.

CAR200808950 13 8.0 Deleted records since records are no longer generated.

12 7.2 Added EDP-ZZ-01 136 as reference.

Page 13 of 14 INFORMATION USE

HTP-ZZ-07101 Rev. 015 Communication Protocol For Leak/Spill And Groundwater Sample Results Sheet I of I Page 14 of 14 INFORMATION USE

WAmeren UE Callaway Plant HTP-ZZ-07101 APPENDIX A REMP SAMPLE LOCATIONS MINOR Revision 015 Page I of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 REMP SAMPLE LOCATIONS TABLE OF CONTENTS Section Page Number

1.0 REFERENCES

3 1.1.

Im plem enting...........................................................................................................................

3 1.2.

D evelopm ental.............................................................

,........................................................... 3 2.0

SUMMARY

OF CHANGES..................................................................................................

3 ATTACHMENT 1, Gamma Dose Collection And Analysis Schedule....................................................

4 ATTACHMENT 2, Airborne Particulate And Iodine.............................................................................

8 ATTACHMENT 3, Well Collection And Analysis Schedule (Potable Water).........................................

9 ATTACHMENT 4, Wells And Ponds Collection And Schedule (Non Drinking Water Wells)............. 11 A TTA C H M E N T 5, Surface W ater.............................................................................................................

13 A T T A C H M E N T 6, Soil................... I.......................................................................................................

14 ATTACHMENT 7, Leafy Green Vetetables...........................................

15 A T T A C H M E N T 8, M ilk.......................................................................................................

...................... 16 ATTACHMENT 9, Fish, Shoreline & Bottom Sediment.......................................................................

17 A T T A C H M E N T 10, Farm Crop.................................................................................................................

18 Page 2 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 REMP SAMPLE LOCATIONS

1.0 REFERENCES

1.1.

Implementing 1.1.1.

FSAR Section 2.1.1.1 1.2.

Developmental None 2.0

SUMMARY

OF CHANGES Section Page(s) or Step Number Description 6 Changed Location for dosimeter #44 CAR 200807515 11 Changed Power Block to granular fill. CAR 200803054 12 Changed ODCM req'd column block entries from QUARTERLY to YES Page 3 of 18 INFORMATION USE Page 3 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 Gamma Dose Collection And Analysis Schedule Sheet 1 of 4 Loc Description Sample Location Analysis ODC Code Frequency M

(each sample)

Req'd la 10.8 mi. NW; City of Fulton on Hwy Z, 0.65 mi.

N38 51.759 Quarterly Yes East of Business 54, W 91 55.972 West of Campus Apartments.

3 1.2 mi. NW; 0.1 mi.. West of Hwy CC on Gravel N 380 46.377 W Quarterly Yes Road, 0.8 mi. South Hwy 0, Callaway Electric 910 47.966 Cooperative Utility Pole No. 18559.

5 1.3 mi. ENE; Primary Meteorological Tower.

N 380 45.9 18 W Quarterly Yes

~~91045.448 6

2.0 mi. W; County Road 428, 1.2 mi. West of N 380 45.833 W Quarterly Yes Hwy CC, Callaway Electric Cooperative Utility 91' 49.048 Pole No. 18609.

7 1.4 mi. S; County Road 459, 2.6 mi. North of N 380 44.496 W Quarterly Yes Hwy 94, Callaway Electric Cooperative Utility 910 46.988 Pole No. 35097.

9 3.8 mi. S; NW Side of the County Road 459 and N 380 42.453 W Quarterly Yes Hwy 94 Junction, Callaway Electric Cooperative 910 47.100 Utility Pole No. 06754.

10 3.9 mi. SSE; Hwy 94, 1.8 mi. East of County N 380 42.522 W Quarterly Yes Road 459, Callaway Electric Cooperative Utility 91' 45.320

___Pole No. 12182.

I la 4.7 mi. SE; City of Portland, N 38c 42.616 W Quarterly Yes Callaway Electric Cooperative 91" 43.454

____Utility Pole No. 12110.______

14 4.9. mi. ESE; SE Side of Intersection Hwy D N 380 43.472 W Quarterly Yes and Hwy 94, Callaway Electric Cooperative 910 42.277

____Utility Pole No. 11940.______

17 3.8 mi. E; County Road 4053, N 380 45.801 W Quarterly Yes 0.3 mi. East of Hwy 94, Kingdom Telephone 910 42.702 Company Pole No. 3XI2.______

18a 3.7 mi. ENE; East side of Hwy D, N 383 46.971 W Quarterly Yes 0.5 mi. South of Hwy 0, Callaway Electric 910 43.083 Cooperative Utility Pole No. 38579.

20 4.7 mi. NE; City of Readsville, Callaway N380 48.534 W Quarterly Yes Electric Cooperative Utility Pole No. 12830.

910 43.121 Page 4 of 18 Page 4of 18INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 (Cont'd.)

Sheet 2 of 4 Loc Description Sample Location Analysis ODCM Code Frequency Req'd (each sample 21 3.8 mi. NNE; County Road 155, N 380 48.780 W Quarterly Yes 1.9 mi. North of Hwy 0, Callaway 910 45.199 Electric Cooperative Utility Pole No 19100 22a 1.9 mi. NNE; North side of Hwy N 38 0 47.238 W Quarterly Yes 0, 100 feet East of County Road 910 46.068.

150, Callaway Electric Cooperative Utility Pole No. 31094.

23 6.6 mi. NNE; City of Yucatan, N 380 511.254 W Quarterly Yes Callaway Electric Cooperative 910 44.999.

Utility Pole No. 12670 26**

11.7 mi. E; Town of Americus, N 380 47.041 W Quarterly Yes Callaway Cooperative Utility Pole 910 34.026.

No. 11159.

27**

9.3 mi. ESE; Town of Bluffton, N 380 42.358 W Quarterly Yes Callaway Electric Cooperative 910 37.472.

Utility Pole No. 11496.

30a 4.4 mi. SSW; City of Steedman, N N 380 42.286 W Quarterly Yes side of Belgian Dr., 150 feet East of 91° 48.967.

Hwy CC, Callaway Electric Cooperative Utility Pole No. 06557.

31a 7.8 mi. SW; City of Mokane, N 380 40.880 W Quarterly Yes Junction Hwy C and County Road 910 52.901.

400, 0.9 mi. North of Hwy 94, Callaway Electric Cooperative Utility Pole. 52071.

32 5.4 mi. WSW; Hwy VV, 0.6 mi.

N 380 44.051 W Quarterly Yes West of County Road 447, 910 52.536.

Callaway Electric Cooperative Utility Pole No. 27031.

32a 5.0 mi. WSW; County Road 447, N 380 43.677 W Quarterly Yes Callaway Electric Cooperative 910 51.788.

Utility Pole No. 06354.

33 7.4 mi. W; City of Hams Prairie, SE N 380 46.006 W Quarterly Yes of Hwy C and Hwy AD Junction.

91' 55.083.

34 9.5 mi. WNW; NE Side of Hwy C N 380 48.751 W Quarterly Yes and County Road 408 Junction.

910 56.705.

35 5.8 mi. NNW; City of Toledo, N 380 50.401 W Quarterly Yes Callaway Electric Cooperative 910 49.070.

Utility Pole No. 17684.

Page 5 of ý18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 (Cont'd.)

Sheet 3 of 4 Location Description Sample Location Analysis ODCM Code Frequency Req'd (each sample 36 4.9 mi. N; County Road 155, 0.8 mi. South of N 380 49.969 Quarterly Yes County Road 132, Callaway Electric W 910 46.218 Cooperative Utility Pole No. 19137.

37 0.5 mi. SSW; County Road 459, 0.9 mi. South N 38' 45.249 Quarterly Yes of Hwy CC, Callaway Electric Cooperative W 91° 47.029 Utility Pole No. 35077.

38 4.6 mi. NNW; County Road 133, 1.5 mi.

N 380 49.277 Quarterly Yes South of Hwy UU, Callaway Electric W 910 49.119 I Cooperative Utility Pole No. 34708.

39 5.4 mi. NW; County Road 111, Callaway N 380 48.844 Quarterly Yes Electric Cooperative Utility Pole No. 17516.

W 910 51.283 39A 5.0 mi. NW; County Road 111, Callaway N 380 48.321 Quarterly Yes Electric Cooperative Utility Pole No. 17526.

W 910 51.224 40 4.2 mi. WNW; NE Side of County Road 112 N 380 47.066 Quarterly Yes and Hwy 0 Junction, Callaway Electric W 910 51.263 Cooperative Utility Pole No. 018145.

41 4.9 mi. W; Hwy AD, 2.8 mi. East of Hwy C, N 380 46.227 Quarterly Yes Callaway Electric Cooperative Utility Pole No.

W 91' 52.240 18239.

42 4.4 mi. SW; County Road 447, 2.6 mi. North N 380 43.302 Quarterly Yes of County Road 463, Callaway Electric W 910 50.706 Cooperative Utility 'Pole No. 06326.

43 0.5 mi. SW; County Road 459, 0.7 mi. South N 380 45.415 Quarterly Yes of Hwy CC, Callaway Electric Cooperative W 910 47.225.

Utility Pole No. 35073.

44 0.1 mi. WSW; Hwy CC, 1.0 mi. South of N 380 45.3 W Quarterly Yes County Road 459, Callaway Electric 910 48.735 Cooperative Utility Pole No. 1877.

45 1.0 mi. WNW; County Road 428, 0.1 mi.

N 380 45.927 Quarterly Yes West of Hwy CC, Callaway Electric W 910 47.912 Cooperative Utility Pole No. 18580.

46 1.5 mi. NNW; NE Side of Hwy CC and County N 380 46.831 Quarterly Yes Road 466 Intersection, Callaway Electric W 910 47.790 Cooperative Utility 'Pole No. 28242.

47 1.0 mi. N; County Road 448, 0.9 mi. South of N 38' 46.522 Quarterly Yes Hwy 0, Callaway Electric Cooperative Utility W 91c 46.692.

Pole No. 28151.

48 0.4 mi. NE; County Road 448, 1.5 mi. South N 380 46.001 Quarterly Yes I of Hwy 0, Plant Security Sign Post.

W 910 46.666 Page 6 of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 (Cont'd.)

Sheet 4 of 4 Loc Description Sample Location Analysis ODCM Code Frequency Req'd (each sample 49 1.6 mi. E; County Road 448, N 380 45.599 W 910 Quarterly Yes Callaway Electric Cooperative 45.096 Utility Pole No. 06959, Reform Wildlife Management Parking Area.

50 0.9 mi. SSE; County Road 459, 3.3 N 380 44.912 W 910 Quarterly Yes mi. North of Hwy 94, Callaway 46.653 Electric Cooperative Utility Pole No. 35086.

51a 0.3 mi. SE; Owner Control Fence, N 380 45.465 W 910 Quarterly Yes SE of the Water Treatment Plant.

46.695 1

52 0.4 mi. ESE; Light Pole Near the N 380 45.593 W 910 Quarterly Yes East Plant Security Fence.

46.492 60**

13.5 mi. SW; Callaway Electric N 380 37.314 W 910 Quarterly Yes Cooperative Utility Pole No. 43744 57.295 I just past Tebbett's City sign.

    • Control Location ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1

-END OF SECTION-Page 7 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 Airborne Particulate And Iodine Sheet I of 1 Loc Description Sample Location Analysis 1-131, ODCM Code Frequency*

&Gamma Req'd (each sample Isotopic Al 1.3 mi. ENE; Primary N 380 45.918 Weekly Yes Yes Meteorological Tower.

W 910 45.448.

A7 9.5 mi. NW; C. Bartley N 380 51.286 Weekly Yes Yes Farm.

W 910 54.734.

A8 0.9 mi. NNE; County Road N 380 46.485 Weekly Yes Yes

448, W 910 46.687.

0.9 miles South of Hwy 0.

A9 1.9 mi. NNW; Community of N 38' 47.168 Weekly Yes Yes Reform.

W 910 47.769.

B3 1.8 mi. NNW; 0.3 mi. East of N 38' 47.192 Weekly Yes Yes the Hwy 0 and CC Junction, W 91' 47.540.

Callaway Electric Cooperative Utility Pole No.

50422 ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 8 of 18 INFORMATION USE Page 8 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 Well Collection And Analysis Schedule (Potable Water)

Sheet 1 of 2 Minimum Sample Volumes:

H 3: 200 ml PGE (Principle Gamma Emitters): 1 gallon Drinking Water Loc Description Sample Location Collection Tritium ODCM PGE (1)

Code Frequency Req'd 1

Miller, Roman N 380 43.399 Quarterly Yes 9136 County Road 461 W 910 47.041 2

Miller, Robert N 380 43.148 Quarterly Yes 9205 County Road 461 W 910 47.07 3

Ward, Rick & Nancy N 380 43.252 Quarterly Yes Yes Yes 9204 County Road 448 W 910 46.225 4

Miller, Albert N 380 43.628 Quarterly Yes Yes Yes 9057 County Road 448 W 910 45.822 5

Hux, Ron N 380 43.797 Quarterly Yes Yes Yes 8802 County Road 448 W 91° 45.605 6

Lindeman, Henry N 380 44.224 Quarterly Yes Yes Yes 8754 County Road 448 W 910 45.353 7

Kriete, Stan N 380 45.145 Quarterly Yes Yes Yes 8304 County Road 448 W 91" 44.683 8

Brandt, John N 380 42.794 Quarterly Yes Yes Yes 9400 County Road 457 W 910 47.711 9

Clardy, Scott & Tammy N 380 43.407 Quarterly Yes Yes Yes 9142 County Road 457 W 910 48.216 10 Dillon, Susan N 380 43.616 Quarterly Yes Yes Yes 9076 County Road 457 W 910 48.305 11 Dillon, Harry N 380 42.94 Quarterly Yes 9291 Dillon Drive W 910 45.94 12 Dillon, Joe N 380 42.71 Quarterly Yes Yes Yes 9549 County Road 464 W 910 45.83 14 Hinnah, Donald N 380 42.746 Quarterly Yes 9360 Sycamore Valley W 910 44.662 Road 15 Schmid, Herbert N 380 42.637 Quarterly Yes 9363 Schmid Way W 910 44.863 16 Smith, Rick N 380 43.145 Quarterly Yes 9602 County Road 468 W 910 45.660 17 McGinn, David N 380 43.278 Quarterly Yes 9704 County Road 468 W 910 45.397 18 McGonigal, Jerry N 380 43.151 Quarterly Yes 9790 County Road 468 W 910 45.070 1

Page 9 of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 (Cont'd.)

Sheet 2 of 2 Loc Description Sample Collection Tritium ODCM PGE Code Location Frequency Req'd (1) 19 Hoover, Darin N 38' 43.160 Quarterly Yes 9538 County Road W 910 45.855 468 20 Schmid, Charlie N 38' 42.833 Quarterly Yes 9349 Schmid Way W 910 44.961 21 Baumgarth, Phillip N 38' 44.651 Quarterly Yes 8729 County Road W 910 44.497 469 22 Robert Plummer N 38 42.541 Quarterly Yes Yes Yes 10402 State Road 94 W 91 43.408 ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Note 1 If contaminated with gamma emitting nuclides of plant origin, analyze for HTD nuclides.

89 0

55 63 237 238 239 240 241 241 24 43/244 HTD nuclides are defined as Sr89, Sr 9, Fe

, Ni, Np

, Pu

,P pu3/24,P p4,.Am24, Cm242 and Cm243/44 Page 10 of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 Wells And Ponds Collection And Schedule (Non Drinking Water Wells)

Sheet I of 2 Minimum Sample Volumes:

H3: 200 mln PGE (Principle Gamma Emitters): 1 gallon PGE: I gallon Boron: As directed by laboratory Loc odeCollection Tritium PGE Boron ODCM NPDES Lo oeFrequency (1)

Req'd Req'd OW-I UHS pond Quarterly Yes OW-2 UHS pond Quarterly Yes OW-3 UHS pond Quarterly Yes OW-4 UHS pond Quarterly Yes OW-5 UHS pond Quarterly Yes MW-001 Outside OCA Quarterly Yes Yes Yes MW-002 Outside OCA Quarterly Yes Yes Yes MW-003 Outside OCA Quarterly Yes Yes Yes MW-004 Dillon Quarterly Yes Yes Yes MW-005 Brownlee/ Hudson Quarterly Yes Yes Yes MW-006 Ward Quarterly Yes Yes Yes MW-007 Ward Monthly Yes Yes MW-008 Ward Monthly Yes Yes MW-009 Pipeline Quarterly Yes Yes Yes MW-010 Pipeline Quarterly Yes MW-01I Pipeline Quarterly Yes Yes Yes MW-012 Ward Quarterly Yes Yes Yes MW-013 Pipeline Quarterly Yes Yes Yes MW-014 Pipeline Quarterly Yes Yes Yes MW-015 Pipeline Quarterly Yes Yes Yes MW-016 Pipeline Quarterly Yes Yes Yes MW-501 Landfill Quarterly Yes MW-502 Landfill Quarterly Yes 936 Granular Fill Diesel Fuel Quarterly Yes Yes Yes Yes Yes Remediation Plant SE of SFP Building 937A Granular Fill Monitoring Well Quarterly Yes Yes Yes 937B Granular Fill Monitoring Well Quarterly Yes Yes Yes Yes Yes 937C Granular Fill Monitoring Well Plant Quarterly Yes Yes Yes Yes East of RW Bldg Drum Storage 937D Granular Fill Monitoring Well Plant Quarterly Yes Yes Yes Yes South of DMTs 937E Granular Fill Monitoring Well Quarterly Yes Yes Yes Yes Yes 937F Granular Fill Monitoring Well Quarterly Yes Yes Yes Yes M-2 Quarterly Yes M-7 Quarterly Yes Page ii' of 18 INFORMATION USE Page It, of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 (Cont'd.)

Sheet 2 of 2 Collection Tritium PGE Boron ODCM NPDES Loc Code Frequency (1)

Req'd Req'd GWS - Ground Water Sump Plant East of Quarterly Yes Yes Yes Yes Yes Containment and SFP Building UHS pond Quarterly Yes Unit 2 pond Quarterly Yes CTBD - Cooling Tower Blowdown Quarterly Yes POND 01 Semi Annual Yes Yes Yes Pond 02 Semi Annual Yes Yes Yes Outfall 010 Semi Annual Yes Yes Yes Outfall 011 Semi Annual Yes Yes Yes Outfall 012 Semi Annual Yes Yes Yes Outfall 013 Semi Annual Yes Yes Yes Outfall 014 Semi Annual.

Yes Yes Yes Outfall 015 Semi Annual Yes Yes Yes Sludge Lagoon #4 Semi Annual Yes Yes Yes Ground Water Wells Loc Description Sample Location Collection H3 &PGE ODCM Code Frequency Req'd DOI 5.0 mi. SE Portland Bar/Grill.

N 380 42.591 Quarterly Yes Yes W 91 ° 43.022 F05 0.9 mi. SSE Onsite N 380 44.939 Quarterly Yes Yes Groundwater Monitoring Well.

W 910 46.681 F15 0.4 mi. NNE Onsite N 380 45.981 Quarterly Yes Yes Groundwater Monitoring Well.

W 91' 46.674 PW1 Callaway Plant Cafeteria.

N/A Quarterly Yes Yes ALL distances are measured. from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

If contaminated with gamma emitting nuclides of plant origin, analyze for HTD nuclides.

89 90 55 63 237 238 239/240 241 42 243/244 HTD nuclides are defined as Sr8 9, Sr9 0, Fe55, Ni6 3, Np

, Pu

, pu23/24, Pu24, Am 24 1, Cm2 2 and Cm 4/4.

Page 12 of 18 INFORMATION USE Page 12 of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 Surface Water Sheet 1 of I Loc Description Sample Location Collection H-3 &

ODCM NPDES Code Frequency Gamma Req'd Req'd Isotopic S01**

4.7 mi. SSE; 105 feet N 38 42.12 Monthly Yes Yes Yes Upstream of Discharge W 91 44.20 Composite North Bank.

S02 4.9 mi. SE; 1. 1 River Miles N 380 42.545 Monthly Yes Yes Yes Downstream of Discharge W91 V 43.232.

Composite North Bank at Portland.

    • Control Location ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 13 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 Soil Sheet I of 1 Loc Description Sample Location Collection Gamma ODCM Code Frequency Isotopic Req'd V3**

15.0 mi. SW; Beazley Farm, N 38-37.14, Annual Yes West of Tebbetts.

W 910 57.91.

F2 1.64 mi. SW; Callaway Plant Forest N 38' 45.189, Annual Yes Ecology Plot F2.

W 910 47.826.

F6 1.72 mi. NE; Callaway Plant Forest N 38' 46.60, Annual Yes Ecology Plot F6.

W 910 45.46....

PR3 1.02 mi. ESE; Callaway Plant N 380 45.45, Annual Yes Prairie Ecology Plot PR3.

W 910 45.87....._

PR7 0.45 mi. NNW; Callaway Plant N 380 46.01, Annual Yes Prairie Ecology Plot PR7.

W 910 47.20.

Wl**

0.61 mi. SE; Callaway Plant N 38° 45.314, Annual Yes Wetlands, High Ground.

W 910 46.588.*

W2 0.60 mi. SSE; Callaway Plant N 38° 45.320, Annual Yes Wetlands, Inlet Area.

W 910 46.572.

W3 0.72 mi. SSE; Callaway Plant N 380 45.203, Annual Yes Wetlands, Discharge Area.

W 91° 46.532.

W4 0.68 mi. SSE; Callaway Plant N 380 45.211, Annual Yes Wetlands, SW Bank.

W 910 46.583.

    • Control Location ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 14 of 18 P INFORMATION USE

HTP-ZZ-07 101 APPENDIX A HTP-ZZ-07 101 APPENDIX A Rev. 015 Leafy Green Vetetables Sheet 1 of 1 Samples collected monthly during the growing season.

The growing season is defined as the months of May through November, however, will vary from year to year due to weather conditions.

Loc Description Sample Location Collection 1-131 &

ODCM Code Frequency Gamma Req'd Isotopic V9 2.0 mi. WNW; Meehan Farm.

N 380 46.401 Monthly Yes Yes W 91° 48.830.

Vii 3.2 mi. NW; Hickman Farm.

N 380 47.962 Monthly Yes Yes W 910 48.874 V12*

18.7 mi. WSW, Kissock Farm, N 380 41.498 Monthly Yes Yes South of New Bloomfield.

W 920 06.953 V15 2.4 mi. NNE; Mike Plate, N 38 47.4250 Monthly Yes Yes 9637 Hwy 0, W91 45.406 Steedman.

    • Control Location ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 15 of 18 INFORMATION USE Page 15 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 Milk Sheet I of I Loc Description Sample Location Collection 1-131 &

ODCM Code Frequency Gamma Req'd (Note 1)

Isotopic M-6 2.64 mi. NW, Eugene Pierce, N 380 47.545 Monthly Yes 7255 County Road 131, Steedman.

W 910 48.612 M-9 Donna S Ferguson, N 38 38.141 Monthly Yes 11638 County Rd 485,Tebbetts.

W91 57.526 M-10 Ravena Dobbs N 380 42.978 Monthly Yes 9100 State Road CC, Steedman.

W 910 49.312 Note 1: Semi-monthly when animals are on pasture, monthly at other times.

ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 16 of 18 INFORMATION USE Page 16 of 18 INFORMATION USE

HTP-ZZ-07101 APPENDIX A Rev. 015 Fish, Shoreline & Bottom Sediment Sheet I of I Loc Code Description Collection Gamma Isotopic ODCM NPDES Frequency Req'd Req'd A**_

4.9 mi. SSE; 0.6 River Miles Semi-Annual Yes Yes Yes Upstream of Discharge North Bank.

C 4.9 mi. SE; 1.0 River Miles Semi-Annual Yes Yes Yes Downstream of Discharge North Bank.

Sei-nna

  • "Control Location Notes: 1.

The fish collection area for location "A" is between 0.6 river miles and 3.0 river miles upstream of the discharge on the north bank and for location "C" is between the discharge area and 1.5 river miles downstream of the discharge on the north bank. The expanded collection areas are needed to guarantee there is sufficient habitat for sampling to ensure the ability to collect the required number of fish species.

ALL distances are measured from the midpoint of the two reactors as described in the FSAR Section 2.1.1.1.

Page 17 of 18 INFORMATION USE Page 17 of 18 INFORMATION USE

HTP-ZZ-07 101 APPENDIX A Rev. 015 0 Farm Crop Sheet 1 of 1 Samples collected at the time of harvest. If harvest occurs more than once a year, sampling shall be performed during each discrete harvest. If harvest occurs continuously, sampling should be monthly.

Three samples of each type of farm crop should be taken along the discharge pipeline easement.

Loc Description Collection H3 & Gamma QDCM Req'd Code Frequency Isotopic FC1 Between discharge pipeline Harvest Yes Yes manhole 8 and the Katy Trail.

FC2 Between discharge pipeline Harvest Yes Yes manholes 5 and 3B.

FC3 Between Hwy 94 and the barge Harvest Yes Yes loading dock access road.

FC4*

Location unlikely to be influenced Harvest Yes Yes by plant operations.

  • One sample of each type of crop sampled along the discharge pipeline, from a control location unlikely to be influenced by plant operations.

Page 18 of 18 INFORMATION USE Page 18 of 18 INFORMATION USE

CaUaway Plant H190.0010 RP-DTI-ENVIRONMENTAL-SPILLRESP RESPONSE TO SPILLS OR LEAKS OF RADIOACTIVE MATERIAL ADMINISTRATIVE CORRECTION Revision 001 Written by: Cary Wohlers PIN: 6404 Date: 3/19/08 Approved by: Chris Graham PIN: 2241 Date: 3/22/08

.Page I of 7 INFORMATION USE

RP-DTI-ENV1RONMENTAL-SPILLRESP Rev. 001 RESPONSE TO SPILLS OR LEAKS OF RADIOACTIVE MATERIAL TABLE OF CONTENTS Section Page Number 1.0 PU R PO SE...........................................................................................................................................

3 2.0 SCO PE................................................................................................................................................

3 3.0 INSTRU CTIO NS...............................................................................................................................

3 4.0 DEFINITIONS...........................................................

7 5.0 REFEREN CES..................................................................................................................................

7 6.0 SUM M ARY OF CHANGES..............................................................................................................

7 Page 2 of 7 INFORMATION USE

RP-DTI-ENVIRONMENTAL-SPILLRESP Rev. 001 RESPONSE TO SPILLS OR LEAKS OF RADIOACTIVE MATERIAL 1.0 PURPOSE 1.1.

This instruction provides guidance for response to a spill or leak of radioactive material that could result in contamination of the groundwater..

2.0 SCOPE 2.1.

This instruction applies to spills or leaks that could potentially result in an on-site or off-site release or migration of radioactive material to the terrestrial environment or to groundwater, surface water, or onto native soil.

2.2.

This instruction does not apply to routine samples obtained pursuant to the Radiological Environmental Monitoring Program (REMP).

3.0 INSTRUCTIONS 3.1.

ENSURE the Radiation Protection Manager or the General Supervisor, Radiation Protection has been notified of the spill or leak.

3.2.

INITIATE a CAR:

3.2.1.

This CAR documents the radiological environmental impact assessment for the event.

3.2.2.

This CAR documents the event in accordance with the recordkeeping requirements of 10 CFR 50.75(g).

3.2.3.

ENSURE the following keywords are assigned to the CAR:

REMP

" RETS DECOMMISSION 3.3.

ASSESS the need for radiological controls:

Dose rate surveys Posting of the area Barricades to prevent entry to the contaminated area 3.4.

OBTAIN samples of the source, and ANALYZE Per Steps 3.7, 3.8, and 3.9.

Page 3 of 7 INFORMATION USE Page 3 of 7 INFORMATION USE

RP-DTI-ENVIRONMENTAL-SPILLRESP Rev. 001 3.5.

DETERMINE IF voluntary notifications are necessary.

3.5.1.

MAKE informal communication before the end of the next business day to the Missouri DNR and local officials with follow-up notification to the NRC regarding a spill or leak to the environment that has or could potentially reach groundwater and meets the following criteria:

The spill or leak exceeds 100 gallons and is from a source containing licensed material.

The volume of the spill or leak cannot be quantified but is likely to exceed 100 gallons from a source containing licensed material.

Any spill or leak, regardless of volume or activity, deemed to warrant voluntary communication.

3.5.2.

The Manager, Regulatory Affairs is responsible for making this informal communication.

3.5.3.

When communicating to the MDNR, local officials, and the NRC regarding a spill or leak, PROVIDE the following information:

A statement that the communication is being made as a part of the NEI Ground Water Protection Initiative.

The date and time of the spill or leak Whether or not the spill has been contained or the leak has been stopped The location of the spill or leak The source of the spill or leak A list of the contaminants and the verified concentrations Description of the actions already taken A general description of future actions An estimate of the potential or bounding annual dose to a Member of the Public, if available at the time of the communication An estimated time/ date to provide additional information or follow-up.

3.5.4.

If voluntary communications are performed, NOTIFY NEI by email at GWNotice@nei.org.

3.6.

SAMPLE the affected area and immediately adjacent area:

Core soil samples at discrete depths Groundwater at the appropriate depth Surface water grab sample or composite sample, as appropriate Page 4 of 7 INFORMATION USE

RP-DTI-ENVIRONMENTAL-SPILLRESP Rev. 001 3.7.

ANALYZE each sample for the radionuclides listed in the following table:

Nuclide Required LLD'1 Principal Gamma Emittersz 5E-7 FIT 1E-6 Gross alpha 1E-7 3.8.

IF any fission products other than H3 are reported, ANALYZE the affected sample for the radionuclides listed in the following table:

13 41 14 3.9.

IF Cs1, Ce4, or Ce144 is identified, or if the gross alpha results are> 2X the normally expected background, ANALYZE the affected sample for the radionuclides listed in the following table:

Nuclide Required LLD" Np2 3/

5E-9 Pu238 5E-9 Pu2 39 240 5E-9 Pu241 5E-9 Am1 5E-9 Cm242 5E-9 Cm 243/ 244 5E-9 3.10.

DETERMINE IF remediation is necessary.

I VCi/gm (dry) for soil and ptCi/ml for water.

The principal gamma emitters are Mn, Fe, Co 58, Co60, Zn65, Mo 99, Cs134, Cs 137, Ce

, and Ce 44. Other gamma peaks that are identifiable shall also be analyzed and reported.

3 H3 should be reported as pCi/ml for the groundwater in the soil.

4 tCi/gm (dry) for soil and pCi/ml for water.

5 ptCi/gm (dry) for soil and pCi/ml for water Page 5 of 7 INFORMATION USE Page 5 of 7 INFORMATION USE

RP-DTI-ENVIRONMENTAL-SPTLLRESP RP-DTI-ENVIRONMENTAL-SP1LLRESP Rev. 001 3.11.

INCLUDE the following information in the environmental impact assessment:

Description of incident with respect to the environment Immediate actions taken to assess the event Actions taken to mitigate the event Remediation actions Identification and concentration of radionuclides Quantities of radionuclides Physical and chemical forms of material(s) (e.g., solubility of the contaminant)

Description of the physical location of the affected areas GPS coordinates Approximate size of the affected area Relationship to landmarks and permanent structures Drawings indicating the location of the affected area Determination of the potential for migration based on the site hydrology study:

To areas outside the Owner Controlled Area To areas beyond the company property To drinking water supplies Dose to the public Dose to plant workers Description of revisions to the Radiological Environmental. Monitoring Program (REMP) resulting from the event Sample chain of custody forms Laboratory analysis reports Final disposition of the affected areas including final contamination levels 3.12. EVALUATE reportability pursuant to the requirements of 10 CFR 50.72(b)(2)(xi).

3.13.

DOCUMENT in the Annual Effluent Radiological Release Report (AERR) all spills or leaks for which voluntary notification was performed.

Page 6 of 7 INFORMATION USE Page 6 of 7 INFORMATION USE

RP-DTI-ENVIRONMENTAL-SPILLRESP Rev. 001 4.0 DEFINITIONS 4.1.

Potential to reach groundwater:

If the spill or leak is directly onto native soil or fill, then it has the potential to reach groundwater.

If the spill or leak is onto an artificial surface (e.g., concrete or asphalt) and the surface is cracked or the material is porous or unsealed, or if the contamination runs off the artificial surface, then it has the potential to reach groundwater.

If the spill or leak is directed into unlined or non-impervious ponds or retention basins (i.e., water hydrologically connected to groundwater), then it has the potential to reach groundwater.

If a spill or leak is inside a building or containment unit, it is generally unlikely to reach groundwater unless there is a pathway, e.g., cracks in the wall or floor of the structure, leaking expansion joints, or leaks in sumps or drains.

If the spill or leak is onto a semi-impermeable surface and it is recaptured or remediated before the close of the next business day, then it does not have the potential to reachgroundwater.

It is irrelevant whether or not the potentially affected on-site groundwater is, or could be used as, a source of drinking water, unless the MDNR has designated that it is not, and cannot be used as, a source of drinking water.

4.2.

Spill or leak: Inadvertent event or perturbation in a system or component's performance.

4.3.

Source containing licensed material: A liquid, including steam, for which a statistically valid positive result is obtained when the sample is analyzed to the required Lower Limit of Detection (LLD).

4.4.

Lower Limit of Detection (LLD): The term LLD is defined in the Offsite Dose Calculation Manual (ODCM).

4.5.

On-site: The Callaway Plant site as described in the FSAR.

5.0 REFERENCES

5.1.

Implementing 5.1.1.

None 5.2.

Developmental 5.2.1.

NEI 07-07, "Industry Ground Water Protection Initiative-Final Guidance Document". August, 2007 5.2.2.