ML082660800

From kanterella
Jump to navigation Jump to search
Summary of Category 1 Meeting with Nine Mile Point Nuclear Station, LLC to Discuss Proposed Extended Power Uprate Application Steam Dryers
ML082660800
Person / Time
Site: Nine Mile Point 
Issue date: 09/29/2008
From: Richard Guzman
Plant Licensing Branch 1
To:
Office of Nuclear Reactor Regulation
Guzman R, NRR/DORL, 415-1030
Shared Package
ML083660777 List:
References
Download: ML082660800 (5)


Text

September 29, 2008 LICENSEE:

Nine Mile Point Nuclear Station, LLC (NMPNS)

FACILITY:

Nine Mile Point Nuclear Station, Unit No. 2 (NMP2)

SUBJECT:

SUMMARY

OF SEPTEMBER 9, 2008, CATEGORY 1 WORKING-LEVEL MEETING WITH NMPNS TO DISCUSS PROPOSED EXTENDED POWER UPRATE APPLICATION RELATED TO STEAM DRYERS On September 9, 2008, a public meeting was held between the U.S. Nuclear Regulatory Commission (NRC), and representatives of NMPNS and its vendor, Continuum Dynamics Inc.,

at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss NMPNSs proposed extended power uprate application related to its steam dryer analyses. Certain portions of the meeting were closed to the public as some of the presentation material and discussion were determined to be proprietary in nature.

There were no members of the public in attendance, and no public meeting feedback forms were received. Enclosure 1 is a list of meeting attendees and Enclosure 2 is a copy of the licensees slides presented at the meeting.

Please direct any inquiries to me at 301-415-1030 or Richard.Guzman@nrc.gov.

/RA/

Richard V. Guzman, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-410

Enclosures:

1. List of Attendees
2. Licensees Handouts/Slides (Non-Proprietary) cc w/encls: See next page

September 29, 2008 LICENSEE:

Nine Mile Point Nuclear Station, LLC (NMPNS)

FACILITY:

Nine Mile Point Nuclear Station, Unit No. 2 (NMP2)

SUBJECT:

SUMMARY

OF SEPTEMBER 9, 2008, CATEGORY 1 WORKING-LEVEL MEETING WITH NMPNS TO DISCUSS PROPOSED EXTENDED POWER UPRATE APPLICATION RELATED TO STEAM DRYERS On September 9, 2008, a public meeting was held between the U.S. Nuclear Regulatory Commission (NRC), and representatives of NMPNS and its vendor, Continuum Dynamics Inc.,

at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss NMPNSs proposed extended power uprate application related to its steam dryer analyses. Certain portions of the meeting were closed to the public as some of the presentation material and discussion were determined to be proprietary in nature.

There were no members of the public in attendance, and no public meeting feedback forms were received. Enclosure 1 is a list of meeting attendees and Enclosure 2 is a copy of the licensees slides presented at the meeting.

Please direct any inquiries to me at 301-415-1030 or Richard.Guzman@nrc.gov.

/RA/

Richard V. Guzman, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-410

Enclosures:

1. List of Attendees
2. Licensees Handouts/Slides (Non-Proprietary) cc w/encls: See next page DISTRIBUTION:

PUBLIC RidsNrrDeEmcb RidsNrrPmTAlexion LPLI-1 R/F RidsNrrPmRGuzman RidsNrrDorlLPLl-1 RidsNrrLaSlittle RidsNrrDorl RidsOgcRp CBasavaraju ATsirigotis RidsRgnIMailCenter RidsAcrsAcnwMailCenter Package Accession No.: ML082660777 Accession No.: ML082660800 Accession No.: ML082750387 OFFICE LPLI-1/PM LPLI-1/LA LPLI-1/BC NAME RGuzman SLittle MKowal DATE 9/22/08 9/23/08 9/29/08 OFFICIAL RECORD COPY

LIST OF ATTENDEES NUCLEAR REGULATORY COMMISSION (NRC)

NUCLEAR REACTOR REGULATION (NRR) CATEGORY 1 MEETING WITH NINE MILE POINT NUCLEAR STATION, LLC (NMPNS)

NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 SEPTEMBER 9, 2008 NAME ORGANIZATION

1. Richard Guzman NRC/NRR/Plant Licensing Branch I-1
2. Kamal Manoly NRC/NRR/Division of Engineering
3. Alexander Tsirigotis NRC/NRR/Division of Engineering
4. Chakrapani Basavaraju NRC/NRR/Division of Engineering
5. Thomas Alexion NRC/NRR/Division of Policy and Rulemaking
6. Jay Laughlin NMPNS
7. Kirk Jenks NMPNS
8. Theresa Darling NMPNS
9. Gary Pavis NMPNS
10. George Inch NMPNS
11. Alan Bilanin Continuum Dynamics, Inc.
12. Frank Cook Monticello
13. Denzel Housley Tennessee Valley Authority

MEETING SLIDES

Nine Mile Point Nuclear Station, Unit No. 2 cc:

Mr. Keith J. Polson Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093 Mr. Michael J. Wallace, Vice-Chairman Constellation Energy 100 Constellation Way, Suite 1800P Baltimore, MD 21202 Mr. Henry B. Barron, President, CEO &

Chief Nuclear Officer Constellation Energy Nuclear Group, LLC 100 Constellation Way, Suite 200C Baltimore, MD 21202 Mr. Terry F. Syrell Director, Licensing Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, NY 13093 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mark J. Wetterhahn, Esquire Winston & Strawn 1700 K Street, NW Washington, DC 20006 Carey W. Fleming, Esquire Sr. Counsel - Nuclear Generation Constellation Energy Nuclear Group, LLC 750 East Pratt Street, 17th Floor Baltimore, MD 21202 Mr. John P. Spath New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Tonko President and CEO New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Gary L. Detter Manager - Nuclear Safety and Security Constellation Energy Nuclear Group, LLC 100 Constellation Way, Suite 200C Baltimore, MD 21202 Mr. James R. Evans LIPA P.O. Box 129 Lycoming, NY 10393