ML081300405

From kanterella
Jump to navigation Jump to search
Transmittal of Final Design Report for the New Alert and Notification System
ML081300405
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 04/28/2008
From: Dacimo F
Entergy Corp, Entergy Nuclear Operations
To: Feeney A
Office of Nuclear Security and Incident Response, State of NY, Emergency Management Office
References
NL-08-059
Download: ML081300405 (180)


Text

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, N.Y. 10511-0249 tff-Tel (914) 734-6700 Fred Dacimo Vice President License Renewal April 28, 2008 Indian Point Unit Nos. 2 and 3 NL-08-059 Mr. Andrew Feeney First Deputy Director New York State Emergency Management Office 1220 Washington Avenue Public Security Building 22 Albany, New York 12226-2251

Subject:

Indian Point Energy Center Alert and Notification System Final Design Report

Reference:

1. Entergy letter (NL-08-032), "Siren Project Milestone Schedule," Mr.

Michael Balduzzi to NRC Document Control Desk, dated February 8, 2008

2. Entergy letter (NL-08-024), "Indian Point Energy Center Alert and Notification System Design Report," Mr. Fred Dacimo to Mr. Andrew Feeney, New York State Emergency Management Office (SEMO), dated January 31, 2008
3. FEMA letter, "Indian Point Energy Center Alert and Notification System Design Report," Mr. Stephen Kempf, Jr. to Mr. Andrew X. Feeney, New York State Emergency Management Office, dated March 7, 2008

Dear Mr. Feeney:

Enclosed for your review is the Indian Point Energy Center (IPEC) Final Design Report for the new Alert and Notification System. This final Design Report includes Section 14.1 discussing siren signal steadiness, repeatability, and reproducibility previously submitted by reference 2 and approved by reference 3. Transmittal of this report is in accordance with the milestone schedule provided by reference 1.

Should you. have any questions regarding this matter, please contact Mr. Michael J.

Slobodien, Director, Emergency Planning, Entergy at (914) 272-3352.

Sin re

yours, F r ed PR.R*". a Vice President License Renewal Indian Point Energy Center A

il NL-08-059 Page 2 of 2

Enclosure:

1.- Indian Point Energy Center Alert and Notification System Final Design Report cc:

Document Control Desk (w/1 Enclosure)

U.S. Nuclear Regulatory Commission Mail Stop O-P1 -17 Washington, DC 20555-0001 Mr. Samuel J. Collins (w/1 Enclosure)

Regional Administrator Region I

.Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406-1415 Mr. Robert Kahler (w/1 Enclosure)

Office of Nuclear Security and Incident Response Division of Preparedness and Response Licensing and Inspection Branch Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Rebecca S. Thomson (w/3 enclosures)

REP Branch Chief Federal Emergency Management Agency Region 11It 26 Federal Plaza, 13 Floor, Suite 1337 New York, NY 10278-0002 Mr. Stephen Kempf, Jr. (w/1 Enclosure)

Regional Administrator Federal Emergency Management Agency Region 11 26 Federal Plaza New York, NY 10278 Mr. Daniel Greeley (w/1 Enclosure)

Deputy Director Rockland County Fire and Emergency Services 35 Fireman's Memorial Drive Pomona, New York 10970 Mr. Adam Stiebeling (w11 Enclosure)

Deputy Commissioner Putnam County Bureau of Emergency Services 112 Old Route 6 Carmel, New York 10512 Mr. Anthony Sutton (w/1 Enclosure)

Commissioner Westchester County Department of Emergency Services 4 Dana Road Valhalla, New York 10595

.Mr. Seam us Leary (w/1 Enclosure)

Deputy Commissioner Orange County Department of Emergency Services 225 Main Street Goshen, New York 10924 Resident Inspector's Office (w/1 Enclosure)

Nuclear Regulatory Commission Indian Point Unit Nos. 2 and 3

NL-08-059 Page 1 of 1 Indian Point Energy Center Alert and Notification System Final Design Report

Entergy Indian Point Energy Center I*

Alert & Notification System Design Report

Alert,and Notification System for the Indian Point Energy Center Entergy Nuclear April, 2008 PREPARED BY:

ENTERGY NUCLEAR AND ACOUSTIC TECHNOLOGY, INC.

EAST BOSTON, MASSACHUSETTS THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF ACOUSTIC TECHNOLOGY, INC. (ATI) It is submitted with the express understanding, to which the recipient agrees, that its contents or any part of them will not be duplicated or disclosed to third parties, nor will proprietary information herein be used to or for any other purpose except review and implementation of the design system, with the prior written consent of ATI having been obtained in each instance. "Proprietary information" means information not previously known to the recipient so long as not generally and properly available to 4

the public.

TABLE OF CONTENTS 1

SUMMARY

1-1 2

INTRODUCTION AND BACKGROUND 2-1 3

SITE DESCRIPTION 3-1 4

DEMOGRAPHIC CHARACTERISTICS 4-1 5

PARKS, MILITARY AND SPECIAL USE FACILITIES 5-1 6

METEROLOGICAL CONSIDERATIONS 6-1 7

SIREN CHARACTERISTICS 7-1 8

GENERAL SYSTEM OVERVIEW 8-1 9

SIREN COMMUNICATION AND CONTROL 9-1 10 COMMUNICATION AND CONTROL SYSTEM RELIABILITY 10-1 11 ACOUSTIC CRITERIA OF SIREN SYSTEM 11-1 12 SIREN ACOUSTIC COMPUTER MODEL BASIS 12-1 13 VERIFICATION OF ATI SIREN ACOUSTIC COMPUTER MODEL 13-1 14 ACOUSTIC TESTING AND ANALYSIS 14-1 15 BACKUP POWER 15-1 16 FAILURE MODES AND EFFECTS ANALYSIS 16-1 17 CONFIGURATION MANAGEMENT 17-1 18 SYSTEM TRAINING 18-1 19 SYSTEM OPERATIONS, TESTING AND MAINTENANCE 19-1 PROCEDURES 20 SIREN SYSTEM ROUTINE TESTING 20-1 21 QUALITY CONTROL 21-1 22 CONCLUSION 22-1 APPENDIX A LISTING OF ACRONYMS A-1 APPENDIX B INDEPENDENT TEST OF THE IPEC PROMPT ALERT B-1 NOTIFICATION SYSTEM

APPENDIX C APPENDIX D APPENDIX E APPENDIX F APPENDIX G APPENDIX H APPENDIX I APPENDIX J APPENDIX K AMBIENT NOISE SURVEY INITIAL TESTING LESSONS LEARNED SYSTEM EQUIPMENT DATA SUPPORTING DOCUMENTATION/REFERENCES CONTROL SYSTEM RELIABILITY TESTING RESULTS SIMULCAST RADIO SYSTEM LOCATIONS OF SIRENS, CONTROL STATIONS, AND REPEATERS (MAP)

SIREN COVERAGE WITHIN THE EPZ OF INDIAN POINT ENERGY CENTER (MAP)

C-1 D-1 E-1 F-1 G-1 H-1 I-1 J-1 K-1 ii

TABLE 7-1 TABLE 8-1 TABLE 8-2 TABLE 9-1 TABLE 10-1 TABLE 13-1 TABLE 14-1 TABLE 14-2 TABLE 14-3 TABLE C-1 TABLE C-2 TABLE E-1 TABLE E-2 TABLE H-1 TABLE H-2 TABLE H-3 TABLE H-4 LIST OF TABLES SIREN CHARACTERISTICS NUMBER OF SIRENS BY COUNTY LOCATIONS OF SIREN SYSTEM CONTROL STATIONS TRANSMISSION TOWER CHARACTERISTICS OPERATIONAL STATES FOR COMMUNICATION AND CONTROL SYSTEM FAR FIELD MEASUREMENTS COMPARED TO ATI MODEL PREDICTIONS AUGUST 11 - AUGUST 14, 2007 STEADINESS OF OMNI-DIRECTIONAL SIREN SYSTEM MEASURED AT THE CENTER MICROPHONE LOCATION

(#3)

SUMMARY

OF TEST RESULTS FROM ANECHOIC CHAMBER TESTS OF NEW OMNI-DIRECTIONAL SIRENS BULK RESULTS FROM THE TESTING OF THE OMNI-DIRECTIONAL SIRENS LOCATION AND DESCRIPTION OF THE AMBIENT MEASUREMENT LOCATIONS THE CUMULATIVE EXCEEDANCES FOR THE 2 8 TH TOB (630 HZ)

ENTERGY CONDITION REPORTS (CR) FROM JANUARY 2004 TO FEBRUARY 2006 COMPARISON OF FORMER AND NEW SYSTEMS IPEC ANS RELIABILITY TESTING IPEC ANS DIAGNOSTIC TESTING (2 PAGES)

ACTIVATION LOCATIONS FOR PERFORMED SEPTEMBER 6-17, 2007 CONTROL SYSTEM TEST RESULTS FOR TESTING PERFORMED SEPTEMBER 6-17, 2007 7-2 8-1 8-6 9-4 10-1 13-2 14-7 14-13 14-15 C-1 C-2 E-4 E-7 H-2 H-3 H-5 H-6 iii

FIGURE 3-1 FIGURE 8-1 FIGURE 8-2 FIGURE 8-3 FIGURE 8-5 FIGURE 8-6 FIGURE 9-1 FIGURE 12-1 FIGURE 14-1 FIGURE 14-2 FIGURE 14-3 FIGURE 14-4 FIGURE 14-5 FIGURE 14-6 FIGURE.14-7 FIGURE 14-8 LIST OF FIGURES POPULATION DENSITY FROM YEAR 2000 CENSUS DATA WITHIN THE EPZ OF INDIAN POINT ENERGY CENTER TYPICAL STATIONARY OMNI-DIRECTIONAL SIREN IN NEW SYSTEM TYPICAL STATIONARY BY-DIRECTIONAL SIREN IN NEW SYSTEM TYPICAL SIREN EQUIPMENT AND CONTROL ENCLOSURE TYPICAL RACK MOUNT CONTROL STATION COMPONENTS TYPICAL COMMUNICATION SYSTEM SCHEMATIC LAYOUT OF FULLY REDUNDANT REPEATER SYSTEM CALCULATION OF SOUND CONTOUR GRID SYSTEM MICROPHONE ARRAY IN ANECHOIC CHAMBER TIME HISTORY OF EACH SPL FOR EACH MICROPHONE IN THE ARRAY DURING THE SOUNDING OF SIREN 331 f=576 Hz TIME HISTORY OF EACH SPL FOR EACH MICROPHONE IN THE ARRAY DURING THE SOUNDING OF SIREN 315 f=576 Hz TIME HISTORY OF EACH SPL FOR EACH MICROPHONE IN THE ARRAY DURING THE SOUNDING OF SIREN 213 f=576 Hz TIME HISTORY OF EACH SPL FOR EACH MICROPHONE IN THE ARRAY DURING THE SOUNDING OF SIREN 113 f=576 Hz STEADY, REPEATABLE, AND REPRODUCIBLE RESULTS FOR BI-DIRECTIONAL SIRENS CONTOUR MAP OF FREQUENCY AND TIME DOMAIN OF A TYPICAL SIREN SOUNDING REPEATABILITY OF ACOUSTIC MEASUREMENTS ON SIREN #331; MICROPHONE #3 DATA 3-2 8-2 8-2 8-4 8-7 8-8 9-6 12-4 14-4 14-4 14-5 14-5 14-6 14-6 14-8 14-8 iv

FIGURE 14-9 FIGURE 14-10 FIGURE 14-11 FIGURE 14-12 FIGURE 14-13 FIGURE 14-14 FIGURE 14-15 FIGURE 14-16a FIGURE 14-16b FIGURE 14-17 FIGURE 14-18 FIGURE 14-19 FIGURE C-1 SCHEMATIC MAP 1 MAP 2 REPEATABILITY OF ACOUSTIC MEASUREMENTS ON SIREN #113; MICROPHONE #3 DATA REPEATABILITY OF ACOUSTIC MEASUREMENTS ON SIREN #315; MICROPHONE #3 DATA REPEATABILITY OF ACOUSTIC MEASUREMENTS ON SIREN #213; MICROPHONE #3 DATA OUTDOOR SIREN REPEATABILITY TESTS RESULTS FROM 2007 REPRODUCIBILITY OF OMNI-DIRECTIONAL SIRENS TESTED IN ANECHOIC CHAMBER IN 2007 OUTDOOR SIREN REPRODUCIBILITY TEST RESULTS FROM 2007 REPRESENTATIVE TIME HISTORIES OF ANECHOIC CHAMBER DATA SHOWING STEADINESS OF ALL TEN OMNI-DIRECTIONAL SIRENS AERIAL VIEW OF OUTDOOR GTRI TEST SITE CLOSER AERIAL VIEW OF OUTDOOR GTRI TEST SITE SCHEMATIC SHOWING RELATIVE MEASUREMENT LOCATIONS AT THE GTRI OUTDOOR TEST SITE VARIABILITY IN MEASURED SOUND LEVEL WITH

.INCREASES IN MEASUREMENT DISTANCE SIREN TEST SAMPLE DATA SHEET TIME HISTORY OF HOURLY EXCEEDANCES FOR PEEKSKILL, NY SIMULCAST RADIO SYSTEM LOCATIONS OF SIRENS, CONTROL STATIONS, AND REPEATERS SIREN COVERAGE WITHIN THE EPZ OF INDIAN POINT ENERGY CENTER 14-9 14-9 14-10 14-10 14-11 14-11 14-16 14-17 14-17 14-18 14-18 14-23 C-3 1-2 J-2 MAP POCKET V

1

SUMMARY

This report describes the Alert and Notification System (ANS) for the Indian Point Energy Center (IPEC) in Buchanan, New York.

The IPEC ANS consists of sirens, broadcasted emergency information, and high speed telephone notification. This system meets the guidelines set forth in the Federal Emergency Management Agency's (FEMA's) regulations, 44 CFR Part 350, Planning Standard E, Appendix 3 of NUREG-0654/FEMA-REP-1, and the Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants (FEMA-REP-10).

The siren system described in this report, in conjunction with other elements of the ANS, achieves the design objectives for coverage specified in Appendix 3 of NUREG-0654/

FEMA-REP-1, and FEMA-REP-10 section E.6.2 in that together they meet the following criteria:

"Capability for providing both an alert signal and informational or instructional message to the population on an area wide basis throughout the EPZ, within 15 minutes."

"The initial notification system will assure direct coverage of essentially 100% of the population within 5 miles of the site."

"Special arrangements will be made to assure 100% coverage within 45 minutes of the population who may not have received the initial notification within the entire plume exposure EPZ."

The ANS relies on omni-directional and bi-directional electronic sirens broadcasting an audible sound tone signal at 576 Hertz to alert the public to obtain information. This information is provided from commercial broadcast networks that participate in the Emergency Alert System (EAS).

The counties located in the Emergency Planning Zone (EPZ) also have arrangements to assure that there is essentially 100% coverage of the population who may not have received the initial alert. In the event of a siren failure, backup alerting will be provided by a high speed telephone calling system capable of delivering geographically customized pre-recorded emergency messages. Geographic Information Systems (GIS) were used to define the messaging area for each siren based on the acoustic coverage that would be potentially affected by a failure of that siren.

Additionally, Tone Alert Radios (TARs) are distributed to special use facilities such as schools and hospitals within the EPZ. Special use facilities are defined as those facilities where a concentration of people are located such as schools, hospitals and industrial or commercial facilities. The TARs are a discretionary method used to augment the siren alerting system; they are not a primary alerting method. On an annual basis, IPEC provides guidance to these facilities on the use and testing of the TARs.

1-1

This report describes the technical features of the siren system including siren features and placement, sound propagation acoustic modeling, control and communications systems, system operation, testing and maintenance, and backup power capabilities.

1-2

2 INTRODUCTION AND BACKGROUND In compliance with Section 651(b) of the Energy Policy Act of 2005, IPEC installed a new ANS system consisting of fixed electronic sirens capable of providing an alert for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after a loss of normal AC power. The battery backup power feature ensures system components operate securely in the event of power failure.

Fixed omni-directional and bi-directional sirens were selected over rotating sirens to maximize the reliability of the system and avoid the problems the previously installed rotating sirens had experienced.

Fixed sirens also provide a uniform sound output which provides better sound coverage than rotating sirens. The number of sirens was also increased over the previous system to provide better sound coverage. As a result, route alerting was able to be eliminated in the Harriman and Bear Mountain Parks.

The sirens were installed on steel poles which extend pole life and withstand environmental challenges. Additionally, susceptible siren wiring is protected from damage because they are installed within the metal poles.

The design of the new system minimizes single points of failure. For example, numerous design features have been incorporated to provide for multiple communication paths.

2-1

3 SITE DESCRIPTION The Indian Point Energy Center (IPEC) is located on the east side of the Hudson River in the Village of Buchanan, New York. Two active and one partially decommissioned nuclear generating units are located at the site and are owned and operated by Entergy Nuclear. The area within the EPZ is entirely within New York State, and includes portions of four counties: Orange, Putnam, Rockland and Westchester. Population densities within the EPZ range are indicated in Figure 3-1. Population density data are also shown in Map 2 (Appendix K).

The general landscape of the area around Indian Point consists of bedrock-supported ridges that generally follow northeasterly structural trends with rather steep and broad swampy valleys. The entire EPZ is mostly characterized by heavy tree cover.

Deciduous species constitute the majority of this cover. In the low-lying areas, elevations range from 50 to 300 feet above mean sea level. The highest elevations in the region are within the Palisades Interstate Park System and are approximately 1,300 feet. These steep, heavily wooded slopes of the Dunderberg and West Mountains to the west-southwest typify the western area of the EPZ. To the east, peaks are generally lower than those to the north and west. In this area, Spitzenberg and the Blue Mountains average 600 feet in height and there is a weak, poorly defined series of ridges, which run mainly in a north-northwesterly direction.

3-1

Figure 3-1. Population Density from Year 2000 Census Data within the EPZ of Indian Point Energy Center IPEC EMERGENCY PLANNING ZONE - POPULATION DENSITY

  • Based on 20O0 Census in 5

-~#05 1

~J The EPZ is bisected in a north-south direction by the Hudson River, which separates Westchester and Putnam Counties on the east from Rockland and Orange Counties on the west.

3-2

4 DEMOGRAPHIC CHARACTERISTICS The following demographic features characterize the area around the Indian Point Energy Center:

Areas with population densities above 2000 people per square mile Inhabited areas with population densities below 2000 people per square mile Rural areas with sparse population densities Parklands, and Military facilities.

The Indian Point Energy Center is located on the eastern bank of the Hudson River, in Westchester County, approximately 35 miles north of Times Square in New York City and approximately two miles southwest of the City of Peekskill.

The major populated areas are located in the northwest region of Westchester County and the northeast region of Rockland County. In Westchester, the municipalities that contain areas that exceed 2000 people per square mile are Peekskill, Ossining, Cortlandt, Yorktown, Croton-on-Hudson and Lake Mohegan. In Rockland County, Stony Point, Haverstraw and Clarkstown have areas that exceed 2000 people per square mile.

Other municipalities with populations exceeding 2000 people per square mile are Lake Peekskill and Putnam Valley in Putnam County, and Highland Falls and Fort Montgomery in Orange County.

The 2000 Census is the source of the population data used in the design report. The 2000 Census data showed that the population within the plume exposure Emergency Planning Zone of Indian Point was 297,733 people. The total resident population within a two mile radius of Indian Point is 12,154 and within a five-mile radius is 77,331.

Population density data was determined by the State of New York and is shown on Figure 3-1.

4-1

5 PARKS, MILITARY AND SPECIAL USE FACILITIES Within the EPZ of the Indian Point Energy Center there are several parks and military facilities, especially on the west side of the Hudson River in Rockland and Orange Counties. These include Harriman and Bear Mountain State Parks in the Palisades Interstate Park System (PIP), and the U.S. Military Academy at West Point. Camp Smith is a military facility on the east side of the Hudson River north of IPEC. The siren system described herein covers these locations except as noted below.

Alerting at the West Point Military Academy is provided by a combination of sirens and their own institutional alerting system. A special Radiological Emergency Communications System (RECS) telephone line has been installed between the control rooms at the Indian Point Energy Center and the West Point Military Pol ice/Ope rations Center and is tested routinely. Alerting information is provided to West Point in the same time frame as the state and county officials. Upon receiving a notification on the RECS telephone line, West Point will initiate its own alert / notification actions.

Siren sound coverage is provided to Camp Smith. Upon activation of the sirens and receipt of the alert message, Camp Smith initiates actions based on their procedures.

5-1

6 METEROLOGICAL CONSIDERATIONS The EPZ climate is broadly representative of the humid continental type, which prevails in the northeastern United States. Winters can bring periods of below freezing temperatures and snowfall to the area while the spring, summer and fall are generally mild. There is occasional humidity in the summer. FEMA-REP-10 guidelines state that the average summer daytime weather conditions be used to calculate siren sound contours. Average summer daytime weather conditions from the IPEC Met Tower and surrounding airports were used as input for the computer model analyses for siren acoustic coverage.

Conditions for June, July and August, were used to assess levels of temperature, relative humidity, and wind speed to determine the summer daytime averages for these parameters.,

The following data for the average daytime meteorological conditions were used in the computer analysis for the siren sound coverage:

Temperature:

78 degrees Fahrenheit.

Relative Humidity:

61 %

Wind Speed:

7.9 mph Wind Direction (from):

210 degrees As FEMA's CPG 17 (Section V) explains, as sound propagates outdoors, it is affected by among other things, atmospheric conditions. Slight changes in the wind speed and direction, variability in the temperature, and small scale local turbulence in the air all contribute to the variations in the sound propagation path from the source to the receiver.,For small propagation distances, the variations are small. However, when the propagation distances become large, the effects increase. For a steady, omni-directional source propagating across 5000 feet of flat ground, micro variations in the atmospheric conditions can produce as much as a 10 dB fluctuation in the received noise over just a few seconds. These impacts have been studied over the years and several research papers have been written about this effect. Because of this variability, it is not possible to infer the steadiness of a signal after it has propagated over long distances. In other words, a variable signal measured far from the source does not imply that the source itself is unsteady. This is backed by a long history of outdoor noise measurements and modeling.

The recent testing conducted for Entergy at the Georgia Tech Research Institute showed significant variation in the received siren signal for distances as short as 400 feet.

Several cases show that, while general meteorological conditions remained steady, the received noise from a steady signal varied as much as 8 dB over the 4 minutes of the test.

6-1

7 SIREN CHARACTERISTICS The IPEC siren system design utilizes fixed (non-rotating) outdoor electronic warning sirens manufactured by Acoustic Technology Inc. (ATI). Specifically, the ATI HPSS32 stationary siren model, primarily in an omni-directional configuration, is used. Sirens are mounted on Class II steel poles at 50 feet above the ground with the exception of five sirens (246, 247, 248, 370, and 371) that are currently mounted on wood poles. The wood poles are scheduled to be replaced with steel poles during the project to remove the old system.

A statistical analysis was performed utilizing 52 independent speaker pair measurements that were taken in the Georgia Tech Research Institute (GTRI) anechoic chamber. The mean sound pressure level of the sample population was 115 dBC Leq with a standard deviation of 0.5 dBC. Using a Chi-Squared analysis, the minimum siren level output is 114 dBC Leq, at the 95% confidence level, for any remaining siren in the total population. Field testing was also performed on 28 siren speaker pairs. The range of the sample pairs for this field testing was 115.2 to 117.4 dBC Leq. In addition, Lmax was consistently measured about 2-3 dBC higher than the Leq value.

The statistically minimum siren output of 114 dBC Leq is used in the sound contour model notwithstanding the fact that the actual output was measured at consistently higher values, thus providing a margin in sound coverage.

At 15 locations, a bi-directional beam configuration, rather than omni-directional, is used to direct sound in two primary directions to provide the most effective coverage of the area. In these cases, an 800-watt or 1600-watt speaker-pair produces a sound output level of 114 dBC Leq and 116 dBC Leq, respectively at 100 feet in the direction of each speaker-pair based on measurements taken at GTRI. For both the omni-directional ahd bi-directional configurations, a 576Hz fundamental tone frequency was used in the computer analysis of the model.

According to ANSI 12.14-1992, the sound pressure level contour calculation depends upon the accuracy of the determination of siren output at 100 feet from the siren, on-axis at siren height. There are two acceptable methods to determine siren output in accordance with FEMA-REP-10: (1) field measurements around at least one-siren of each type used within the Emergency Planning Zone (EPZ) or (2) anechoic chamber tests, in a laboratory whose chamber meets qualification standards, on sirens that are representative of each type used in the EPZ. Because of the variability of field measurements which can be significantly affected by uncontrollable environmental factors, IPEC concluded that the anechoic chamber measurements extrapolated out to 100 feet would provide a conservative representation of the true siren output, thereby providing margin in sound coverage.

The independent acoustic rating from the Georgia Tech Research Institute - Anechoic Chamber Testing for both the omni-directional and the bi-directional sirens is provided in Appendix B.

Table 7-1 provides the location and type (omni-directional or bi-directional) of each of the sirens in the system.

7-1

Table 7-1. Siren Characteristics 101 0-1 Orange 41.3904

-73.9733 HPSS32 Omni-Directional N/A N/A 102 0-2 Orange 41.3931 103 0-3 Orange 41.3329 104 0-4 Orange 41.3439 105 0-5 Orange 41.3 547 106 6 Orange 41.3145 107 0-7 Orange 41.3209 108 0-8 Orange "41.3060 109 0-9 Orange 41.2604 110 0-10 Orange 41.2739 II1 0-11 Orange 41.3716 112 0-12 Orange 41.3365 113 0-113 Orange 41.3503 114 0-115 Orange 41.3282 115 0-116 Orange 41.3734 116 N/A*

Orange 41.379 117+

N/A*

Orange 41.3884 118 N/A*

Orange 41.4261 119+

N/A*

Orange 41.2116 120+

N/A*

Orange 41.2334 121 N/A*

Orange 41.2749 122 N/A*

Orange 41.2758 123 N/A*

Orange 41.1134 201 R-13 Rockland 41.2965 202 R-14 Rockland 41.2632 203 R-15 Rockland 41.1356

-74.0647

-74.1206

-74.0562

-74.1027

-74.1370

-74.0755

-74.0373

-74.0863*

-74.1173

-73.9641

-73.9822

-73.9697

-74.0025

-74.0145

-74.0986

-74.0144

-74.0383

-74.1422

-74. 1647

-74.1494

-74.0875

-74.1057

-73.9901

-73.9909

-74.0382 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 Omni-Directional N/A N/A Bi-Directional 85 175 Omni-Directional N/A N/A Omni-Directional N/A N/A Bi-Directional 85 175 Onni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Bi-Directional**

45 135 Bi-Directional**

20 290 Bi-Directional**

130 220 Bi-Directional**

15 195 Bi-Directional**

20 195 Bi-Directional**

25 155 Bi-Directional**

25 335 HPSS32 Omni-Directional HPSS32 Omni-Directional HPSS32 Omni-Directional HPSS32 Omni-Directional N/A N/A N/A N/A N/A N/A N/A N/A 7-2

'Current Former Siren Siren No.

No.<v**><*i*-:

204 R-16 205 R-17 206 R-18 207 R-19 208 R-20 209 R-21 210 R-22 211 R-24 212 R-27 213 R-28 214 R-29 215 R-30 216 R-31 217 R-32 218 R-34 219 R-35 220 R-209 221 R-201 222 R-202 223 R-204 224 R-208 225 Rp-2i0

226, R-21 1 227 R-212 228 R-240 229 R-243 230 R-244 Bi-Wiecti6%ial~

Latitude N Longitude

~iei

<~Angles7~

ou r y

.(D ecu mal..

(D ecim a, 111A

-Siren SeireeT y s from

~~D~rees)"~P Moe

-reth)

Dere A

D-e-g MoelsrueNo

  • =.......*.'*r#;"'

D

>+re s) ^..

.. r es +*£**^

..'**lvoa i, #,.:::> <.

=*.,..

I st 2

.1,,

I'drtijq Rockland 41.2289

-74.1160 Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland

'Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland Rockland 41.2081 41.2322 41.2212 41.1888 41.1961 41.1701 41.2352 41.2042 41.1868 41.1868 41.1766 41.1584 41.1600 41.1349 41.1348 41.0846 41.2414 41.2045 41.2210 41.1351 41,1605 41.1977 41.1992 41.1305 41.1705 41.1691

-74.0923

-74.0448

-74.0265

-74.0284

-74.0600

-74.0678

-73.9852

-73.9835

-73.9577

-73.9950

-73.9620

-73.9882

-73.9697

-73.9909

-73.9754

-73.5703

-73.9991

-74.0246

-74.0050

-73.9505

-73,9450

-73.9702

-74.0101

-73.9273

-73.9783

-74.0039 HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A 7-3

N o,..

N o.

e¢ c*

P e

I.

1 I.

231 R-246 Rockland 41.1361 232 R-248 Rockland 41.1495 233 R-251 Rockland 41.1699 234 R-252 Rockland 41.1578 235 R-253 Rockland 41.1516 236 R-256 Rockland 41.1641 237 R-257 Rockland 41.3119 238 R-258 Rockland 41.1714 239 R-259 Rockland 41.2257 240 R-260 Rockland 41.2505 241+

N/A*

Rockland 41.1256 242+

N/A*

Rockland 41.1803 243 N/A*

Rockland 41.1997 244+

N/A*

Rockland 41.2277 245+

N/A*

Rockland 41.2695 246 R-207 Rockland 41.1426 247 R-237 Rockland 4 1.2245 248 R-247 Rockland 41.1432 249 R-203 Rockland 41.1150 250 N/A*

Rockland 41.0707 251 R-23 Rockland 41.0949 252 R-33 Rockland 41.0849 253#

R-36 Rockland 41.1465 301 W-37 Westchester 41.1501 302 W-38 Westchester 41.1559 303 W-40 Westchester 41.1679 304 W-41 Westchester 41.1771

-74.0075

-74.0145

-74.0501

-74.0692

-74.0513

-74.0827

-73.9913

-74.0257

-73.9706

-74.0129

-74.0028

-74.1296

-74.1290

-74.0844

-74.0304

-73.9753

-73.9843

-74.0302

-73.5946

-73.5654

-74.0159

-73.5925

-73.9350

-73.8599

-73.8354

-73.8383

-73.8485 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32 HPSS32

.HPSS32 HPSS32 HPSS32 HPSS32 Bi -Directionoal (D~ese from True North)/

1 St

.2nd~

Omini-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional

'N/A N/A Omni-Directional N/A N/A Bi-Directional**

80 170 Bi-Directional**

20 200 Bi-Directional**

45 135 Bi-Directional**

225 315 Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A 7-4

Current Fornieil 1-iLtitude N Longitude NV Angfles~<

Siren Siren "1,

(cia (Decimial Siren ielkp D-esfo NI No.

Degrees)A

'Degrccs)^

oe True North)-

~~~

N

~

St

'2nd 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330.

331 W-42 Westchester W-43 Westchester W-44 Westchester W-45 Westchester W-46

-Westchester W-47 Westchester W-49 Westchester W-50 Westchester W-51 Westchester W-53 Westchester W-55 Westchester W-56 Westchester, W-57 Westchester W-58 Westchester W-59 Westchester W-60 Westchester W-62 Westchester W-63 Westchester W-64 Westchester W-65 Westchester W-66 Westchester W-67 Westchester W-68 Westchester W-70 Westchester W-71 Westchester W-72 Westchester W-73 Westchester 41.1763,

-73.8697 HPSS32 Omni-Directional N/A N/A 41.1888 41.1829 41.2106 41.2080 41.1894 41.2075 41.1839 41.2138 41.2413 41.2247 41.2375*

41.2547 41.2593 41.2702 41.2658 41.2919 41.2897 41.2668 41.2589 41.2669 41.2734 41.2850 41.2998 41.2987 41.3181 41.2926

-73.8381 HPSS32 Omni-Directional N/A N/A

-73.8139 HPSS32 Omni-Directional N/A N/A

-73.7989 HPSS32 Omni-Directional N/A N/A

-73.8358 HPSS32 Omni-Directional N/A N/A

  • -73.866 HPSS32 Omni-Directional N/A N/A

-73.8816 HPSS32 Omni-Directional N/A N/A

-73.8984

-73.8993

-73.8816

-73.8766

-73.8504

-73.7725

-73.8103

-73.7801

-73.8368

-73.8246

-73.8549

-73.8729

-73.9161

-73.9468

-73.9290

-73.9261

HPSS32, Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional' N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional

.N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A

-73.9259 HPSS32 Omni-Directional N/A-N/A

-73.9472 HPSS32 Omni-Directional N/A N/A

-73.9057

HPSS32, Omni-Directional N/A N/A

-73.8815 HPSS32 Omni-Directional N/A N/A 7-5

~Bi' Directional:

Current Former

~

Latitude N ~Long-itude Ang Jes Siren Sire County (Decimial (Decimal Siren Siren Type.

(Degrees from

-No.

No.4 Degrees)"

KModet4 T~.j Noi~ h)

I 1St 2nid 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 W-74 Westchester W-75 Westchester W-76 Westchester W-79 Westchester W-301 Westchester W-303 Westchester W-304 Westchester W-305 Westchester W-306 Westchester W-307 Westchester W-308 Westchester W-309 Westchester W-310 Westchester W-314 Westchester W-315 Westchester W-316 Westchester W-317 Westchester W-318 Westchester W-319 Westchester W-321 Westchester W-323 Westchester W-324 Westchester W-326 Westchester W-327 Westchester W-328 Westchester W-329 Westchester W-331 Westchester 41.3116 41.3218 41.3213 41.3295 41.2566 41.2847 41.3198 41.3239 41.3272 41.2838 41.3040 41.3020 41.3091 41.2552 41.2780 41.3283 41.2396 41.2315 41.2544 41.1600 41.3121 41.3277 41.3029 41.2946 41.3059 41.3278 41.3297

-73.8709 HPSS32 Omni-Directional N/A N/A

-73.8457 HPSS32 Omni-Directional N/A N/A

-73.8150 HPSS32 Omni-Directional N/A N/A

-73.8423 HPSS32 Omni-Directional N/A N/A

-73.9580 HPSS32 Omni-Directional N/A N/A

-73.9151 HPSS32 Omni-Directional N/A N/A

-73.9422 HPSS32 Omni-Directional N/A N/A

-73.8012 HPSS32 Omni-Directional N/A N/A

-73.7859 HPSS32 Omni-Directional N/A N/A

-73.8947 HPSS32 Omni-Directional N/A N/A

-73.8578 HPSS32 Omni-Directional N/A N/A

-73.9076 HPSS32 Omni-Directional N/A N/A

-73.8966 HPSS32 Omni-Directional N/A N/A

-73.9349 HPSS32 Omni-Directional N/A N/A

-73.8575 HPSS32 Omni-Directional N/A N/A

-73.9146 HPSS32 Omni-Directional N/A N/A

-73.9346 HPSS32 Omni-Directional N/A N/A

-73.9073 HPSS32 Omni-Directional N/A N/A

-73.8807 HPSS32 Omni-Directional N/A N/A

-73.8662 HPSS32 Omni-Directional N/A N/A

-73.8342 HPSS32 Omni-Directional N/A N/A

-73.8773 HPSS32 Omni-Directional N/A N/A

-73.7947 HPSS32 Omni-Directional N/A N/A

-73.8052 HPSS32 Omni-Directional N/A N/A

-73.7782 HPSS32 Omni-Directional N/A N/A

-73.8613 HPSS32 Omni-Directional N/A N/A

-73.823 I HPSS32 Omni-Directional N/A N/A 7-6

Currenti~i F,,i

!r Latitude-N L

3Siren W-31 s

COhete 42

(,Decimal No.

No.~~~

Degrees)'

359 W-333 Westchester 41.2841

.ongLitude'W Degr 111,11 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 401 402 403 404 405 406 4*07 408 409 W-335 Westchester W-358 Westchester W-380 Westchester W-382 Westchester W-384 Westchester W-386 Westchester N/A*

Westchester N/A*

Westchester N/A*

Westchester N/A*

Westchester W-48 Westchester W-322 Westchester W-54 Westchester W-311 Westchester W-312 Westchester W-52 Westchester N/A*

Westchester W-78 Putnam P-80 Putnam P-81 Putnam P-82 Putnam P-83 Putnam P-84 Putnam P-85 Putnam P-86 Putnam P-87 Putnam 41.1387 41.2668 41.2803 41.2411 41.2265 41.2240 41.3191 41.2964 41.2593 41.2271 41.1937 41.1626 41.1500 41.1755 41.1837 41.1415 41.1858 41.3418 41.3520 41.3684 41.3458 41.3491 41.3606 41.3802 41.3864 41.3666

-73.7842

-73.8306

-73.7937

-73.8278

-73.9056

-73.8070

-73.8237

-73.7802

-73.7575

-73.7476

-73.7644

-73.8796

-73.8464

-73.5637

-73.5341

-73.5302

-73.5511

-73.4753

-73.7980

-73.8210

-73.8671

-73.8773

-73.9180

-73.8350

-73.9411

-73.8989

-73.9002 i

P 2rue N/Aiil HPSS2 Oni-iren toa Type I

/

HPSS32 OmiDrcinl N/A N/

1 St /2ndk HPSS32 Omni -Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Bi-Directional**

30 120 HPSS32 Bi-Directional**

30 120 HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omn i-Directional N/A N/A HPSS32 Omni-Directional N/A N/A HPSS32 Omni-Directional N/A N/A 7-7

I Current Fne Siren{

"Siren

~No.N County Latitude N L*rngitude Ws (Decimral

(*(Decis*al

~<Degrees),

Degrees),

Siren7 Model L

410 P-88 Putnam 41.3812

-73.8604 \\

HPSS32

,411 P-89 Putnam 41.4240

-73.9527 HPSS32 412#

N/A*

Putnam 41.4076

-7319202 HPSS32 413 N/A*

Putnam 41.3887

-73.8141 HPSS32 414 N/A*

Putnam 41.3700

-73.7847 HPSS32 415#

N/A*

Putnam 41.2030

-73.5327 HPSS32

  • Newly added siren locations.
    • Sirens using TH400 speakers.

+ Siren powered by solar panels.

  1. Final locations pending as of 4/7/08.

A Latitude/longitude coordinates are referenced to datum GCS WGS. 1984.

Z O ni-irctin i N/A N/kiAl

~An,,I~f Snire ci T

e (Degrees fromN Siren ype ~

True North)i Ist O i2nad Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A N/A Omni-Directional N/A

-N/A 7-8

8 GENERAL SYSTEM OVERVIEW The number of sirens in each of the four counties within the EPZ is summarized in the table below:

Table 8-1. Number of Sirens by County Nw Sstem-Iumber of Sirens, Total Westchester 76 Rockland 53 Orange 23 Putnam 15 Total 167 Sirens Electronic stationary sirens are used in this system. The sirens provide reliable alarm tone notification for warning areas in a community and are capable of voice reproduction when enabled. This omni-directional electronic siren configuration (Figure 8-1) is certified to produce a 360-degree pattern of at least 114 dBC Leq sound pressure (rated at 100 feet on axis at siren height). The bi-directional electronic siren configuration (Figure 8-2) is certified to produce a sound pressure level of at least 114 dBC Leq for each 800 watt beam or 116 dBC Leq for each 1600 watt beam (rated at 100 feet on axis at siren height). The sound pattern from multiple fixed omni-directional sirens is designed to provide a greater added effect by creating an increased sound level exposure at full volume, compared to the previous design that used rotating sirens.

Stationary sirens are advantageous since they maintain a constant output level in all directions. The design of the speaker assembly allows the siren to still operate even if some drivers were to fail although there would be a reduction in sound output. The siren units are driven by battery power with sufficient capacity to provide 15 minutes of operation after a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> loss of external power. There are 167 sirens in the Indian Point warning system. Of those, 136 sirens use essentially the same locations as the previous rotating sirens they are replacing, while the remaining 31 are in new locations.

8-1

Figure 8-1. Typical Stationary Omni-Directional Siren in New System Omni-directional Stationary Electronic Siren One hundred and fifty-two (151) sirens are omni-directional and fifteen (15) use the bi-One hundred and fifty-two (151) sirens are omni-directional and fifteen (15) use the bi-directional configuration (Figure 8-2).

Figure 8-2. Typical Stationary Bi-Directional Siren in New System Bi-directional Stationary Electronic Siren 1600 Wtt Acoustic Beam 8-2

Siren Station Components Each omni-directional siren includes the following components:

Eight Horns (HPSS32), each containing four 100-watt compression drivers NEMA 4X Stainless Steel Enclosure with three separate compartments: an upper compartment for the electronics and two lower ventilated compartments for the batteries.

Siren Amplifier Controller Board Auxiliary Amplifier Board Wireless Radio Wireless Modem Temperature-compensated Battery Charger On/Off Switch for the Battery Charger On/Off Circuit Breakers for Siren Power On/Off Circuit Breakers for heater Four 12V, Gel Cell Batteries Intrusion Switch Battery Heater and Thermostat Cell Antenna Omni-Directional or YAGI (directional) Antenna with low loss coaxial cable The omni-directional High Power Speaker Station (HPSS32) in the IPEC system utilizes the model TH 300 speaker and is a state-of-the-art electronic siren capable of producing 3200 watts of audio power (400 watts per speaker) and includes all of the above components. It uses advanced microprocessor-based circuitry.

Two different bi-directional configurations are used. In the first configuration, the bi-directional HPSS32 which utilizes the model TH 400 speaker is capable of producing 3200 watts (800 watts per speaker) and also includes all of the above components, except that it uses four speakers (two per direction, configured vertically), each containing two 400-watt compression drivers.

In the second configuration, the bi-directional HPSS32 which is an omni-directional HPSS32 (utilizing the model TH 300 speaker) with two pairs of speakers enabled, is capable of producing 1600 watts (400 watt per speaker), and includes all of the above 8-3

components, except uses four speakers (two per direction, configured vertically), each containing four 100-watt compression drivers.

The HPSS32 sirens are 24V DC powered sirens using deep cycle gel cell batteries which are trickle charged with an 8 Amp temperature-compensated Battery Charger.

Seven (7) sirens are solar powered.

The electronics and batteries are housed in a stainless steel NEMA 4X enclosure (see Figure 8-3) as a standard feature, providing protection from adverse outdoor weather conditions. With AC power available, the battery compartment is heated, thus enabling the batteries to function at full capacity when the outside temperature drops.

The HPSS enclosure (NEMA 4X) contains the ATI Siren Amplifier Controller Board (SAB), which integrates both the microprocessor control and audio amplifier circuitries.

It contains a control section, communication section, input/output section, and 1600W amplifier section. The Auxiliary Amplifier Board contains an additional 1600 W amplifier section.

The HPSS enclosure also contains a highly efficient audio amplifier design (up to 95%),

resulting in very low heat dissipation during standard operation with lower power requirements, leading to longer battery life.

Figure 8-3. Typical Siren Equipment and Control Enclosure NEMA 4X Siren Equipment and Control Enclosure 8-amp efficient temperature compensated battery charger Two banks of batteries Four gel cell deep cycle batteries The SAB board is a microprocessor-based board. It has an embedded modem, analog to digital converter, serial port interfaces, and a wireless communication interface. The board is programmed from a regular PC using a special utility program.

8-4

The communication section of the board interfaces to an off-the-shelf wireless radio.

The radio is used to send and receive wireless messages to and from the control station incorporating Frequency Shift 'Keying (FSK) data transmission schemes. The board will perform specific activations dependent upon the wireless messages sent by the control station in addition to responding to other types of service messages, (i.e. polling, acknowledgements, and synchronization messages). The board will report to the control station any local faults, such as intrusion, AC and/or charger failures, and low battery conditions.

A redundant communication path using TCP/IP protocol is also available. The siren controller board interfaces to a wireless modem.

The board monitors the battery voltage of the siren internally and the charger voltage. It will enter Power Shutdown Mode if the battery voltage goes below a pre-set value and generates an alarm report.

Control System The communication control system uses eleven (1-1) control stations that are designed to have complete control and monitoring capabilities over all sirens in the system. Each control station includes a REACT-4000 Communication Control Unit (CCU), TCP/IP cell modem with an attached computer, LCID monitor, printer, keyboard, track ball, batteries, and uninterruptible power supply, all generally within a rack-mounted enclosure (See Figure 8-5). There are two (2) control stations located at Indian Point Energy Center that control all 167 sirens. There are three (3) control stations located in Westchester County controlling 76 sirens, two (2) control stations located in Putnam County controlling 15 sirens, two (2) control stations located in Orange County controlling 23 sirens, and two (2) control stations located in Rockland County controlling 53 sirens. Table 8-2 lists the locations of the control stations.

Each county has complete activation control and monitoring over the sirens used to alert its county from all control stations located within its county and can monitor the activation of all sirens via the computer display. Each county can also monitor sirens from bordering counties that may affect their county. All counties can also activate other counties' sirens if agreed upon. The two control stations at IPEC can also activate all of the sirens if needed.

All control stations have battery back-up power capable of providing a minimum of twenty-four (24) hours of operation in case of primary power failure. The system incorporates reliable communication and post activation polling using radio and TCP/IP communication.

8-5

Table 8-2.

Locations of Siren System Control Stations Lo..atio.

.Address Indian Point Emergency Operations Indian Point Energy Center Center (EOF) 450 Broadway Buchanan, NY 10511 Indian Point General Service Indian Point Energy Center Building (GSB) 450 Broadway Buchanan, NY 10511 Westchester Co. EOC Hudson Valley Traffic Management Center 200 Bradhurst Avenue Hawthorne, NY 10532 Westchester Co. Alternate EOC Michaelian Office Building 148 Martine Ave.

White Plains, NY 10601 Westchester 60 Control 4 Dana Road Valhalla, NY 10595 Rockland Co. EOC Fire Training Center 35 Fireman's Memorial Drive Pomona, NY 10970 Rockland Co. Warning Point 44 Control Fire Training Center 35 Fireman's Memorial Drive Pomona, NY 10970 Orange Co. EOC 22 Wells Farm Road Goshen, NY 10924 Orange Co. Warning Point 911 Center 22 Wells Farm Road Goshen, NY 10924 Putnam Co. EOC Putnam County Training & Operations Center 112 Old Route 6 Carmel, NY 10512 Putnam Co. Warning Point Putnam County Sheriff's Department 3 County Center Carmel, NY 10512 8-6

Figure 8-5. Typical Rack Mount Control Station Components Rack Mount Control Station LCD Monitor Control Station N

Keyboard &

Track Ball Computer Printer Batteries 8-7

Communication System There are two separate and distinct communication paths used to convey activation and monitoring messages between the control stations and the remote sirens: dedicated redundant simulcast radio systems and a cellular TCP/IP system. The overall system showing both paths is illustrated in Figure 8-6. The design eliminates single points of siren communication failures since multiple control stations can communicate to every assigned siren by either communication path. To further increase the Radio Frequency (RF) system reliability, all activation transmission messages are sent out multiple times.

By sending out multiple redundant activation messages, the probability of all desired sirens activating is increased even in the presence of random radio interference.

Figure 8-6. Typical Communication System Radio Communication Path 220 MHz M

MW 220 MHz I a

  • f_- 220 MHz a

MW

~

N IARRIANMW ITWI 22C S220 MHz-a T1 a

TI I

RASSLANDTE a

~TWKER HILL TOWER Sirens TCP/IP Communication Path TCPRP 220 MHz TCPnP a

Central Control Stations The dedicated simulcast radio system uses redundant transmitters and associated equipment operating in the 220 MHz range to communicate between the control stations, towers and sirens, and it uses either microwave or Telco T1 paths for inter-tower communications. Only one of the redundant simulcast paths is configured to be used at a time to transmit signals. Dual antennas (one for each radio path) are located at each of the four tower sites (IPEC Met Tower, Harriman, Grasslands, and Tinker Hill Towers), and they are used in the communication paths between the control stations, towers, and sirens.

8-8

All radio communication, equipment used in the microwave communication path (control stations, towers and.sirens) has a confirmed battery backup for at least twenty-four (24) hours of operation in case of AC power loss. This same backup is provided for the Telco Ti path with the exception that the commercial carrier has not confirmed a 24-hour backup capability for the Telco Ti lines.

A cellular TCP/IP data network that uses cellular data modems provides redundant communications between all control stations and sirens. Cell modems and antennas are located at all sirens and control stations. Signals are transmitted using commercial carriers, and they seek out appropriate paths between the control stations and sirens.

Communications equipment that is physically located at the sirens and control stations use the same backup battery supplies that are used for the radio communications channel. However, the cell modem commercial carrier has not confirmed a 24-hour backup capability on loss of AC power.

By using the simulcast radio system and the cellular modem communications paths concurrently and in a parallel manner for all communications between the control stations and the sirens, a reliable communication system is achieved. Each communication path is designed to achieve reliable delivery of a successful activation message from any control stations.

8-9

9 SIREN COMMUNICATION AND CONTROL Control Control, as used herein, refers to those functions that are used to activate the sirens, monitor siren system functionality, and receive condition status and alarms from the sirens.

The siren control system consists of eleven independent and redundant control stations.

Each county has at least two control stations. One is located at each county's Warning Point (WP) that is manned continually on a round-the-clock basis. Another station is located at each county's Emergency Operations Center (EOC). Westchester County has a third control station located at its backup EOC. Two control stations are located at IPEC.

Each control station consists of one computer system, one cell modem for TCP/IP communications, one REACT 4000 Communications Control Unit (CCU) for radio communications, and a UPS and backup batteries. The computer runs control and monitoring software.

The Internet/Cellular system utilizes the computer, cell transceiver, and cell antenna at each control station to initiate activation and polling commands to the sirens and to monitor results. The computer is programmed to activate a pre-defined group of sirens and is the main component used to activate and monitor the sirens using the TCP/IP path. Transmission paths between the control stations and sirens use commercial carriers that are independent of the Radio System.

The Radio System uses a REACT 4000 to initiate and monitor activation and polling commands to the sirens. It is also programmed to activate a pre-defined group of sirens.

It can operate independently without the computer, but is normally aligned so that it processes activation and polling commands initiated by the computer. Activation using the Radio System sends activation signals to the Internet/Cellular system and vice versa.

Typically, the control stations in the individual counties of Orange, Putnam, Rockland, and Westchester are set to activate and monitor only those sirens within their own jurisdictions. However, the control units can be set up with the ability to activate sirens in any and all jurisdictions. In this way, the control units provide redundancy and backup to other control stations. If a control station in one of the counties were out of service, its sirens could be activated by another control station within the county, or if agreed, by another county. All of the computer/REACT-4000/cell modem units have battery backup power capable of providing a minimum of 24-hours of operation in case of primary power failure.

Sirens can be 'activated. by either the REACT-4000 alone (radio) or the computer (REACT 4000 or TCP/IP). Upon initiation, activation signals can be sent over the following two pathways simultaneously:

  • The 220-MHz radio to the radio transmission towers, which then transmits signals to the siren network via 220 MHz, and 9-1

Commercial cell phone modem network/internet (TCP/IP, Transmission Control Protocol/Internet Protocol) to the individual sirens and control stations where cellular modems receive the signals.

The 220 MHz radio interface is built into the REACT-4000 unit and the TCP/IP interface is connected through the computer. In normal operation, the REACT-4000 and the computer communicate so that activations, initiated by either unit, are sent out over both paths. If either the REACT-4000 or the computer is non-functional, the other component can still transmit activations over the remaining path.

The use of either of these two pathways is sufficient to activate the sirens. The control stations poll the individual sirens using the same communications pathways to determine siren status and function. The control station computer is password-controlled so that it can be set for use in its primary county, or as a backup for other counties as required.

Sirens are routinely polled to report on operational readiness. Key system parameters that are monitored include communications, AC power availability, siren and control station operability and battery status.

Communication - General Overview There are two separate and distinct communications paths between the control stations and sirens:

Redundant 220 MHz simulcast radio networks linking all sirens and CCUs through repeater towers

" Commercial cellular TCP/IP connectivity to all sirens and control stations The radio pathway and cellular TCP/IP pathway operate concurrently.

The dedicated simulcast radio network is comprised of four towers sites, each with redundant radio hardware to communicate activation and status monitoring signals between the control stations and sirens. Signals received by any tower will result in these signals being communicated to all towers. The signals are then re-sent in a coordinated manner to all sirens and control stations as appropriate, to minimize signal interference. There are two redundant radio paths used to communicate between the control stations and sirens. Each path includes radio antennas at each tower, radio frequency transmitters/receivers at each tower and a communication link between towers. Only one of these paths is in full operation at a time, with the other normally in standby. The receiver paths at the towers are always maintained in operation and can therefore process any signals received, but only one transmitter can operate depending on which one is selected to be in service. Failure of the in-service path would result in automatic transfer to the standby path. There are no shared components in the signal transmission path used to activate and monitor the sirens except for the equipment building and tower structure, the equipment maintaining the time stamp for synchronization with the sirens, and both paths share the same battery backup. The control circuits used for tower alarms and channel switching are also shared.

9-2

The towers communicate to each other through redundant communication links. One of these communication links uses microwaves and the other uses Telco Ti telephone lines. The redundant controlling electronics for processing the multiple signals received by the towers are located in different facilities. For the Ti path, it is the IPEC Met Tower and for the microwave path it is Tinker Hill Tower.

Control signals to transfer between communication links are processed through the IPEC General Support Building (GSB) with the capability to manually transfer this function to the IPEC EOF as a backup. Loss of one of the tower communication links would not prevent the Radio System from activating or monitoring the sirens.

One complete radio path for status monitoring and activation (microwave path) has a confirmed 24-hour battery backup capability via one channel of the radio system. Most of the redundant path (Telco Ti) in the radio system also has a confirmed 24-hour battery backup capability. The one exception is the communication link between the towers that uses Telco Ti lines operated by the local telephone carrier. Table 9-1 describes the characteristics for the transmission towers. The locations of the sirens, control stations, and repeaters are depicted on Map 1.

The cellular TCP/IP siren activation and monitoring pathway does not rely on the repeater towers; it processes signals directly between the control stations and the sirens.

Alarms and status monitoring of signals to and from the sirens are processed using the same dual paths that are used for siren activation.

Each repeater tower also has a monitoring unit which provides alarm monitoring and control for the radio system at the towers and communicates to the control stations by a separate radio and TCP/IP cell modem, each having its own antenna. The monitor processes signals to indicate alarm conditions at the repeater towers resulting from component failures, activates or blocks either the microwave transceivers or the Telco Ti line transceivers depending on which tower communication path is desired, powers down several components in the standby channel if there is a loss of AC power at the towers, and initiates a transfer between the microwave mode and Telco Ti mode when conditions dictate (manually, automatically on a major component failure, or automatically on a regular schedule, if selected). Each control and alarm communication path to the towers is independent of the other except where these signals are processed through common circuit boards and where components in the redundant communication paths are housed in common enclosures at the control stations and towers. The monitoring units at the towers share the 24-hour battery backup supply.

9-3

,, Table 9-1. Transmission Tower Characteristics.

Towe'r:

iLatitude *N Longitude W PrimaySeondary RF Microwav..e..

'(Decimal-(Decimal Akntenna iType

-Antenna Typ.

Dish He0ight 1, Dgi*s)**!

Iegree)*

Height "Height.

IPEC Met 41.2706

-73.9500 Omni-directional Omni-directional 220 208' Tower 220 MHz / 340' MHz / 320' Harriman 41.3033

-74.1150 Omni-directional Omni-directional 220 55' 220 MHz / 80' MHz / 38' Tinker Hill 41.3847

-73.8368 Omni-directional Omni-directional 220 50', 100', 180' 220 MHz / 120' MHz / 100' (3 dishes)

Grasslands 41.0804

-73.8065 Omni-directional Omni-directional 220 338' 220 MHz / 294' MHz / 294' (inverted)

  • Latitude/longitude coordinates are referenced to datum GCS WGS 1984.

Radio Path Primary communications from the control stations to the individual sirens are distributed through the four simulcast radio towers described in Table 9-1. The transmitter towers are linked to provide simulcast operation. The Effective Radiated Power (ERP) from the transmitter towers is 200 watts with 50 watts ERP talkback power. Using the four towers in simulcast mode, coverage is obtained from any of the eleven (11) control stations to all assigned siren sites.

Each simulcast radio site is comprised of two separate and redundant 100 watt simulcast radio repeaters. Each of the sirens and each of the CCUs are equipped with a 25 watt radio to communicate over the simulcast network. The simulcast radio network uses 220 MHz frequencies licensed to Entergy through the National Rural Telecommunication Cooperative (NRTC).

In addition to redundant communications, the siren system has other redundant features that were designed to ensure operability of the siren network.

9-4

Specifically:

Each CCU operates independently and can communicate with every siren in the system using any one of the communications paths.

All sirens, CCUs and the synchronized microwave simulcast radio sites are battery backed up for a minimum of 24-hours.

All activation messages are sent out multiple times to ensure that they are received.

Wireless TCP/IP Networks The cellular data network uses modems to provide a redundant communication pathway between all control units and the sirens. Several methods are employed to prevent unauthorized access to the siren system via these cellular links. Data are extensively checked. The modems are programmed to respond only to other modems within an assigned block of static IP (internet protocol) addresses.

The cellular system is provided by a commercial carrier regulated by the Federal Communications Commission and the New York State Public Service Commission.

These systems have backup power capabilities. The cellular networks use data transmission channels and are faster and more reliable than voice carrying channels.

Cellular networks automatically seek out and utilize the most efficient pathway. Field tests have verified that the connectivity between and among the sirens in the EPZ is of high quality such that no additional network capability is required.

Figure 8-6 provides a diagram of the redundant simulcast communication system.

Figure 9-1 provides a simplified schematic diagram for the repeater system. A detailed schematic of the simulcast radio system is located in Appendix I.

9-5

Figure 9-1. Schematic Layout of Fully Redundant Repeater System Four Towers with redundant repeaters Fully Redundant Repeater System (for maximum reliability)

Three Microwave Links Redundant Simulcast Controllers oter abiner Hill IPEC Met Tower 9-6

10 COMMUNICATION AND CONTROL SYSTEM RELIABILITY The design of the ATI siren system facilitates reliability testing. The entire system can be tested from end to end as a means of ensuring that all components are functioning in accordance with the design. Due to the large number of independent control stations and the modes of operation, there are a large number of possible combinations of control stations and transmission pathways. There are eleven independent control stations. Each station can operate in one of five modes or it can be in a "not in service" condition, for a total of six possible states for each control station. The possible operational states for each control station are shown in Table 10-1.

Table 10-1. Operational States for Communication and Control System TCP/IP alone Microwave Synchronized Radio alone T-1 Telco Synchronized Radio alone TCP/IP plus Microwave Synchronized Radio TCP/IP plus T-1 Telco Synchronized Radio Not in Service System reliability testing was conducted during the period August 1-14, 2007, including two full system soundings on August 11 and 14, 2007. A "Student T" test was employed to determine the statistical basis for the portion of this reliability testing program that used the microwave radio communication pathway. The "Student T" test is a statistical method of determining if the averages and variances between two populations are'likely to have occurred by chance or because there is a real difference in the populations. This statistical method is suitable for small populations.

The results of the August 1-14, 2007 reliability testing are tabulated in Appendix H. The data tables show the date of the test, the locations from which the testing took place, and the communication pathway(s) that were used for the testing. Test results are provided on a county by county basis and on an overall system basis.

10.1 System Performance There was no instance in which a hardware failure caused a system-wide inability to activate sirens. One of the significant advantages of the new system is that is designed to address the potential for individual hardware failures. The system'incorporates the physical separation of redundant components to enable activation from other locations within the affected county and from locations outside of the county. Furthermore, the failures observed in the testing all occurred when the system was placed in an off-normal configuration to test a single activation pathway. In normal use, the configuration utilizes all three independent activation pathways. If a large fraction of an individual county's sirens or even all of the sirens in a single county were to fail to sound on the first activation demand in an actual emergency condition, the following alternatives would be available:

1) The affected county could utilize its other control station(s) to activate sirens.
2) The affected county could request one of the other counties to activate the sirens in the failed county jurisdiction.

10-1

3) The affected county could request IPEC to activate the sirens from one of its control stations.
4) Finally, the affected county could utilize the back-up methods for alert and notification.

The above strategy would successfully address each of the three siren failures noted below.

10.2 History of Significant Activation Failures During the new system reliability testing conducted August 1-14, 2007, there were three instances during the reliability testing in which a significant fraction of the sirens failed to activate in an individual county. The causes of these events, corrective actions, and actions to prevent recurrence are described below.

During the testing, there was one instance when an entire county's sirens failed. This event occurred on Tuesday, August 14, when Westchester County's 71 sirens failed to activate during a TCP/IP only signal test from the county Emergency Operations Center (EOC). A review of this event established that the failure was the result of an artificial siren system configuration put in place in order to test one of the three activation communication pathways. The normal siren system configuration keeps all three communication pathways active. In order to test one particular communication path, the other two must be placed into a shutdown condition.

Investigation of'the event on August 14 revealed that the Westchester County control statiorn had been shutdown at the completion of the prior test. Since the unit was inactive for a period of time, the cellular modem went into the sleep mode and therefore was unresponsive for the first test. The "sleep" mode is a condition in which the component is in a reduced power configuration to conserve battery power. In normal use, this condition does not occur because the periodic testing keeps the component in an active or "awake" mode. The modem was reset, the scheduled second test was performed, and all but one Westchester County siren activated.

This condition would not occur during a normal configuration. In an actual event, the control station at the county's other activation location would be used to activate the sirens immediately as described above. This event was documented in IPEC Condition Report CR-IP2-2007-3254.

There were two other instances that occurred in Orange County during testing where a significant number of the county's sirens failed to activate. These tests occurred on August 1 and August 8. Both tests used only the radio/microwave communication signal. The August 1 test resulted in 19 of the 22 sirens not receiving an activation signal. The August 8 test resulted in 10 sirens not receiving the activation signal. These events were caused by a failure to reboot a computer at the CCU following software updating. The software was not activated until the reboot occurred. This was attributed to technician error. In an actual event, the control station at the county's other activation location would be used to activate the sirens immediately as described above. This event was documented in IPEC Condition Report CR-IP2-2007-3209.

The cause for each of these failures was identified and corrective action was taken to address them.

10.3 Continued Testing IPEC continued to conduct communication and control system reliability testing that expanded on the statistically based testing that was conducted in August and September 2007. This round of reliability testing concluded on September 17, 2007. The test results for the complete testing are also included in Appendix H. The testing regime demonstrated that overall system reliability is well above 90% as called for in the applicable FEMA guidance. Given the 10-2

configuration of the communication and control system, there are many combinations of activation and communication control. The testing regime tested those that are most likely to be used including individual county activations from EOCs and warning points in various combinations and the ability of both Westchester County and Rockland County to activate sirens on behalf of all four counties. The testing provides reasonable assurance that the installed communication and control system will function in all modes as designed. As suggested by FEMA, testing concentrated on, but was not limited to, the microwave synchronized simulcast radio communication and control mode. In that mode, overall reliability is in the range of 97-98 percent.

10.4 Reliability Testing and Performance Results The testing performed in August and September has been sufficient to provide a greater than 95% confidence level that the results of the microwave synchronized simulcast radio activation and control mode reflected actual system capability and did not occur merely by random cha~nce.

Those results have demonstrated high reliability (greater than 97%) for that activation and control mode. Furthermore, the testing has not revealed any unanticipated failure modes. Overall success rates for all activation modes were also greater than 97 percent.

10-3

11 ACOUSTIC CRITERIA OF SIREN SYSTEM NUREG-0654 and FEMA-REP-10 indicate that adequate siren sound levels are as follows:

" The expected siren sound pressure level generally exceeds 70 dBC where the population exceeds 2,000 persons per square mile and 60 dBC in other inhabited areas; or The expected siren sound pressure level generally exceeds the average measured summer daytime ambient sound pressure levels by 10 dBC (geographical areas with less than 2,000 persons per square mile).

Additionally, the NUREG 0654 Appendix 3 guidance that the notification system will "assure direct coverage of essentially 100% of the population within 5 miles of the site" has been further defined in the Shearon Harris Atomic Safety and Licensing Board (ASLB) decisions to mean "...the required essentially 100% which we equate with greater than 95% during summer nighttime conditions within 5 miles"... and 90% within 10 miles.

Inhabited areas are depicted on Map 2 (Appendix K).

11-1

12 SIREN ACOUSTIC COMPUTER MODEL BASIS The siren sound contours of 60 and 70 dBC, within the IPEC EPZ, were calculated by a computer model developed by ATI. These contours are shown on Map 2. The computer model evaluates meteorological factors, topographical factors and ground conditions. These factors affect the propagation of the sound signal generated by a siren. FEMA-REP-10 guidelines state that the average summer daytime weather conditions should be used to calculate siren sound contours-since they are the most conservative conditions where sound propagation is most challenged. Average summer daytime weather conditions were used as input for the model analyses for siren acoustic coverage.

In accordance with relevant sections of ISO 9613-2 and ANSI S12.18-1994, the acoustic model is programmed with appropriate information pertaining to a source-receiver orientation, source sound characteristics, and path obstructions and characteristics. There are three types of data inputs required for the program:

Siren Data - The siren dominant frequency in hertz and sound output at 100 feet on axis at siren height in dBC.

Meteorological Conditions - Meteorological information, including temperature, wind speed, wind direction, relative humidity and barometric pressure.

Topographical and Ground Conditions - A receiver grid system is established for the entire EPZ. Each source-receiver path is then scanned and relevant path information including effective source and receiver heights, ground characteristics, major obstructions and intervening tree cover is derived. Available topographical and ground cover condition data are used to determine sound attenuation factors (See Figure 12-1).

The various sound attenuation factors considered in the sound propagation analysis by the computer model are summarized below.

Spherical Wave Divergence The change in the sound pressure level from spherical divergence is uniform in all directions and occurs at a rate of 6 dB per doubling of distance from the sound source. This non-dissipative sound pressure level attenuation is a result of the decrease in energy density (energy per unit area) of the propagating sound wave. The energy density of a sound wave decreases as the distance from a sound source increases because of the increase in the surface area over which the constant energy of the wave is distributed.

Atmospheric Absorption Molecular (atmospheric) absorption further reduces the sound energy. This dissipative sound level attenuation is from inelastic collisions of air molecules. Absorption is dependent on the temperature and the relative humidity of the air, and is proportional to distance and pronounced at frequencies higher than the frequency of 576 Hz selected for the IPEC sirens.

12-1

Barrier Attenuation Effects A mound of earth, a hill or a structure, if large enough, is a partial barrier to sound and can reduce sound levels within its shadow zone. The sound attenuation caused by a barrier is estimated by the computer model. The ATI computer model determines the effective barrier height, which is the height above the line-of-sight from the siren to the receiver location.

The other two essential dimensions are the distance from the siren to the barrier, and the distance from the barrier to the receiver. These dimensions are used to calculate the attenuation of sound from the barriers. Topographical data from USGS maps are used to calculate the sound attenuation from barrier effects caused by the high elevations generating acoustic shadow zones behind ridges and hills.

There are well developed analytical methods for calculating the extent of attenuation of sound by barriers. In general, these methods have been experimentally verified. These are used to calculate this effect. The model considers single or multiple barriers interrupting the siren signal. If multiple barriers exist, the most prominent barrier is utilized. The barrier effect is calculated. Field verification from these methods has been conducted and modified for accuracy.

Near-Field Interference Factors All of the siren locations were surveyed to evaluate potential near-field obstructions that can attenuate the sound from the siren. Tree trimming was required and completed at many locations to mitigate this attenuation. This effort is described in the IPEC reports entitled "Report on Trees and Tree Trimming at the Indian Point Energy Center (IPEC) Alert Notification Siren Sites, September 24, 2007 to November 17, 2007," Volumes I and II, November 30, 2007. Additionally, the effect of co-located sirens was documented in CR-IP2-2007-04611 and concluded that there is not significant degradation in sound propagation from co-located sirens such that the function to alert the public is impaired.

Ground Effects Sound attenuation is also a function of the ground cover and the siren's height. The ground cover conditions were determined directly from USGS maps at various directions and distances from the installed siren location. These conditions were used to calculate the sound attenuation due to the absorptive effect of the different ground coverings.

The primary path of the outdoor sound propagation is the direct line-of-sight path; the secondary path is the ground-reflected path. Both of these paths are subject to sound attenuation due to the effect of ground cover between the sound source and distant locations.

In general, five types of ground cover are distinguishable from USGS maps for evaluation by the ATI computer model:

Dense vegetation - forests and thick brush are the kinds of ground cover that attenuate sound to the greatest extent.

Wooded marsh - vegetation attenuates sound, but water reflects sound to a certain extent, so attenuation by this ground cover. is not as great as that caused by denser vegetation.

12-2

Water, marshes - water acts as a reflector for sound propagation, so attenuation over water is very slight.

Open fields - where there is no dense vegetation or other barriers to sound, attenuation is slight.

Urban and suburban areas - sound reflects well from pavement at acute incidence angles.

Sound is attenuated to a significant extent, however, in urban areas close to the siren because buildings act as sound barriers and reflection is poor because of high incidence angles. In urban areas further away from the siren, sound propagates with a low attenuation rate as a result of increased reflection due to the lowered angle of incidence.

Wind Shadows Wind gradients near the ground are usually positive; that is, wind speed increases with height.

As a result, a wind shadow zone is most commonly encountered upwind of a siren because headwinds with positive wind gradients bend sound upward. Downwind, the sound rays are bent downward and no shadow zone is produced. Crosswind, there is a zone of transition which is more difficult to model.

ATI starts with established formulas for wind attenuation. ATI then modifies those formulas utilizing proprietary factors developed by its extensive field measurements from sirens around nuclear sites.

Foliage Attenuation ATI uses empirical data to evaluate the effect of tree foliage.

Methodology For each siren, the area around the siren is divided into Polar coordinates of 24 150 segments and the radial distance (r) from the siren. For each segment an acoustic ray is projected based on the rated sound pressure level output, as described in Section 14. The acoustic ray sound pressure level is reduced by each of the applicable attenuation factors and site specific terrain factors described above. For each sound ray, the distance from the source corresponding to C-weighted 70 dBC and 60 dBC is determined as a point (X, Y) coordinate for a Cartesian coordinate grid system. The contours are scaled and overlaid on US Geological Survey topographical maps. This entire process is then repeated for each and every set of source-receiver pairs and used to develop a matrix of values from which the sound contours can be extrapolated for the entire EPZ.

12-3

Figure 12-1.

Calculation of Sound Contour Grid System Land Cover

  • Trees I

Water U

Houses Commercial Areas I

Highway W

Receiver for which a sound level is calculated 0

500 lJ0 1.506 2000 2500 3000 350 Scale in Feet Example 1 hl Barier Effect hs =

50 fee t

Ien)

To rap yProf

{

J,.

Land Cover 12-4

13 VERIFICATION OF ATI SIREN ACOUSTIC COMPUTER MODEL The ATI acoustic model was used to predict the sound coverage of the new sirens in the IPEC EPZ. The siren locations and designated siren sound pressure level output in dBC Leq were input into the model. The ATI model then computed expected siren levels throughout the EPZ.

ATI produced a sound contour map which depicts 70 dBC and 60 dBC contour lines over the IPEC EPZ. Individual locations have specific predicted values based on GPS coordinates. The input value for each siren output was 114 dBC Leq.

To verify the accuracy of the ATI model, IPEC contracted with Wyle Laboratories to use its "Sound Acoustic Model" (SAM) to prepare a similar sound contour map. The identical sound pressure level of 114 dBC Leq was used as input to produce the sound contour map. The two maps were compared for similarities and differences. The two acoustic consultants produced nearly the same results. The contours lines were in essentially the same locations. The two acoustic consultants compared their results and were satisfied that both maps reasonably predicted the actual sound coverage.

To further confirm the quality of the ATI predictions, 24 high population density locations in the far field were measured during full alert siren soundings on August 11 and 14, 2007. The actual measurements are shown in Table 13.1. The input values for the ATI model predictions were siren height values (approximately 114 dBC) correlated from actual ground level readings. These measurements were compared to the predicted sound pressure levels for these locations. A bulk average deviation method, as described in Section 14.4, was used to analyze this data. Extremely close alignment was shown.

Thus, the ATI model has been demonstrated to be reasonably accurate in predicting sound coverage in the EPZ.

13-1

WTable 13-1.

Far Field Measurements Compared to ATI Model Predictions August 11 - August 14, 2007 ATI ocation e

Laiue Longitude Predictio Lmax L10 Leq LO*:i?

ý:ý ii attd

(dBC))

(.B".

(dBC)'i (dBC)

(d...

Cortlandt 8/11/2007 41.2530639

-73.9622806 71 83.3 77.6 74.8 Cortlandt 8/14/2007 41.2511944

-73.9453500 72 79.9 77.4 73.7 Croton-On-Hudson 8/11/2007 41.2026972

-73.8823083 71 75.7 72.3 68.3 Croton-On-Hudson 8/14/2007 41.2111750

-73.8909528 72 89.2 78.9 75.6 Fort Montgomery 8/14/2007 41.3402639

-73.9923167 64 63.0 54.2 52.4 Haverstraw 8/11/2007 41.1992250

-73.9807972 71 90.6 76.7 75.3 Haverstraw 8/14/2007 41.1941861

-73.9636528 73 83.4 78.8 75.3 Highland Falls 8/11/2007 41.3570639

-73.9695278 72 85.1 80.0 76.8 Highland Falls 8/14/2007 41.3665194

-73.9655833 73 79.0 69.9 67.9 Lake Peekskill 8/11/2007 41.3490111

-73.8686833 71 75.7 70.7 67.6 Lake Peekskill 8/14/2007 41.3380750

-73.8791278 71 66.2 61.8 58.9 Mohegan Lake 8/11/2007 41.3119056

-73.8513861 73 83.6 77.7 74.7 Mohegan Lake 8/14/2007 41.3194306

-73.8558500 73 80.9 75.3 72.3 New City 8/14/2007 41.1535111

-73.9881222 75 91.1 86.3 82.8 Ossining 8/11/2007 41.1459306

-73.8654167 69 77.4 69.2 66.4 Ossining 8/14/2007 41.1643611

-73.8540889 71 73.3 70.7 67.7 Peekskill 8/11/2007 41.2810472

-73.9227972 72 82.2 74.5 71.5

_Peekskill 8/14/2007 41.2948833

-73.9155417 72 78.9 73.9 71.1 utnam Valley 8/14/2007 41.3861806

-73.8509139 70 69.9 68.2 66.2 "I1Putnam Valley 8/11/2007 41.3766139

-73.8599917 75 87.4 82.9 79.3 Stony Point 8/11/2007 41.2325111

-73.9798500 74 76.7 73.1 70.4 Stony Point 8/14/2007 41.2409667

-73.9909056 80 92.9 89.6 86.4 Yorktown Heights 8/11/2007 41.3089528

-73.7904056 75 73.8 69.5 66.3 Yorktown Heights 8/14/2007 41.3159472

-73.7970111 71 74.7 70.6 66.3 13-2

14 ACOUSTIC TESTING AND ANALYSIS 14.1 Steady, Repeatable, and Reproducible This section of the design report addresses the siren output characteristics of steadiness, repeatability, and reproducibility. Set forth below are the definition of each characteristic, how such characteristic was determined, and the documentation of test results. Georgia Tech Research Institute (GTRI) in Smyrna, Georgia established the testing methodology, conducted the testing, and provided the testing results which establish that the new Indian Point Alert and Notification System (ANS) sirens meet all applicable FEMA standards and guidance.

Figure 14-1 shows the location of the nine (9) microphone cruciform array in relation to the siren speaker array inside the anechoic chamber. This equipment arrangement is consistent for all of the tests performed by GTRI in the anechoic chamber. The central microphone was aligned with the center of the siren speaker array and data from this microphone were used in test results and analyses.

Steadiness The definition of siren steadiness is the ability to maintain an alerting signal at a constant sound pressure level and signal frequency as a function of time. The standard for steadiness is + 2.0 dBC established by FEMA during the technical meeting held between ENOI and FEMA on November 9, 2007 and is based on the caption to Figure 1 in CPG 1-17.

The GTRI testing demonstrates that the siren output is steady in accordance with FEMA guidance in CPG 1-17 and as discussed below.

Siren time history curves depict sound pressure level (SPL) versus time. Siren time history curves for four omni-directional sirens are provided in Figures 14-2 through 14-5. Each of the nine (9) time history curves associated with individual microphones follows the same pattern but at different sound pressure levels. Time history data recorded from the center microphone (#3) in the array for multiple activations are shown in figures 14-8 through 14-11. The center microphone was selected because it represents the on-axis center of the siren array location.

Table 14-1 lists the range of siren sound variation for 28 independent speaker pair tests from four omni-directional sirens.

The GTRI data demonstrate that the omni-directional siren sound output during normal operation, which excludes an initial transient, varies between 0.16 and 0.49 dBC or 0.34 dBC on average over a 3-4 minute time period. Excluding the transient sound pressure level that occurs with signal initiation, the omni-directional sirens demonstrate a steady signal with sound pressure levels varying by less than 0.5 dBC over a 3-4 minute sounding period. The initial transient sound pressure level reduction of approximately 1.0 dBC over the first 20-24 seconds of siren operation is due to the initial electrical burst from the siren amplifiers. The ANSI S12.14-1992 criteria allows for initial transients in accordance with paragraph 6.2.3.1 which states "Observations shall be made over a period of at least 30 seconds after the warning sound source has reached steady operation."

Results of the GTRI tests indicated that the bi-directional siren sound output, excluding the initial transient varied by less than 0.40 dBC over-a 3-4 minute sounding period. Figure 14-6 shows the data that demonstrate signal steadiness for the bi-directional siren system.

14-1

Based on the GTRI testing data, the steadiness range for both the omni-directional and bi-directional sirens is within 0.5 dBC over a 3-4 minute sounding period and meet the applicable FEMA standards and guidance.

Steady frequency output was measured for the siren activations of both omni-directional and bi-directional sirens at the standardoperating frequency of 576 Hz as well as other frequencies including 660, 675, and 780 Hz. Frequency of the siren output was steady to within + 1.0 Hz over a 3-4 minute sounding period. Figure 14-7 shows the constancy of frequency during a representative siren sounding.

The independent GTRI testing results demonstrate that both the omni-directional and bi-directional sirens produce a steady alerting tone frequency in accordance with FEMA standards and guidance.

Repeatability The definition of repeatability is the ability of a siren to produce the same sound level output and tone frequency during multiple activations. The standard for repeatability is + 2.0 dBC established by FEMA during the technical meeting held between ENOI and FEMA on November 9, 2007 and is based on the caption to Figure 1 in CPG 1-17, page 10.

The GTRI testing demonstrates that the siren output is repeatable as discussed below.

Figures 14-8 through 14-11 show the representative test results of four different omni-directional sirens during several different activations. Data from the central microphone show sound pressure level variation ranging between 0.8 and 1.4 dBC. These data demonstrate that the omni-directional siren system is repeatable within a 1.4 dBC range over a 3-4 minute sounding period. Figure 14-6 shows that the bi-directional siren is repeatable within a 0.6 DBC range over a 3-4 minute sounding period.

In addition, in situ outdoor testing performed in the summer of 2007 within the Indian Point EPZ and shown in Figure 14-12 indicates very similar repeatability results for both the omni-directional and bi-directional sirens. The maximum in situ outdoor repeatability range for 5 omni-directional siren tests was 1.1 dBC and for the two bi-directional siren tests was 0.3 dBC.

The independent GTRI testing results demonstrate that both the omni-directional and bi-directional sirens are repeatable in accordance with the FEMA standard established by the FEMA staff.

Reproducibility Reproducibility is defined as the ability of a group of sirens to produce acoustic output that is consistent from one siren to another. The standard for reproducibility was established by the FEMA staff at a technical meeting between ENOI and FEMA on November 9, 2007.

The GTRI testing demonstrates' that the siren output is reproducible as discussed below.

Reproducibility was demonstrated by' comparing the sound pressure level output of different sirens. Figure 14-13,.shows anechoic-chamber results from twenty-eight (28) sound tests from four differentomni-directional sirens with different speaker pairs facing the microphone array.

14-2

The data demonstrate that the omni-directional siren systems are reproducible to within a + 2.0 dBC band,.. iThis is further demonstrated by outdoor tests results performed in situ within the Indian Point EPZ in the summer of 2007 and shown in Figure 14-14. Excluding one outlier (siren 213), outdoor in situ testing on the remaining 16 sirens measured on axis at 100 feet at siren height had a + 2.0 dBC band. Anechoic chamber test results for siren 213 projected to 100 feet are well within the + 2.0 dBC range. Additionally, outdoor tests results obtained from siren 213 at GTRI were also within the + 2.0 dBC range. These results suggest that the outlying reading for siren 213 shown in Figure 14-14 was due to outdoor environmental effects.

Anechoic chamber and in situ outdoor tests described above demonstrate that the omni-directional sirens are reproducible.

Figure 14-6 shows the reproducibility of two bi-directional sirens to be within 1.0 dBC. This reproducibility is further supported by in situ outdoor tests whose data are shown in Figure 14-

12. The in situ outdoor reproducibility test between bi-directional sirens 116 and 120 using the worst case combination is 0.6 dBC. Therefore, the bi-directional sirens are reproducible to within a + 2.0 dBC band over a 3-4 minute sounding period.

The independent GTRI testing results demonstrate that both the omni-directional and bi-directional sirens are reproducible in accordance with the standard established by the FEMA staff.

14-3

Figure 14-1. Microphone Array in Anechoic Chamber Figure 14-2. Time History of Each SPL for Each Microphone in the Array during the Sounding of Siren 331 f = 576 Hz (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Typical Steadiness of Siren Siren #331; IT&IB Facing Mic Arrary; f 576 Hz 139) 138.

137 132 135 L'133-0maurlshton

-*131"

S130, 1269 Nowaoollr 124 6M*I 127-MCOPhM It2 122.

MnMp*)ndW 83j 124 70 9D 110 130 150 t70 100 210 230 250 270 250 310 330 350 Tim. [seconds]

14-4

Figure 14-3. Time History of Each SPL for Each Microphone in the Array during the Sounding of Siren 315 f = 576 Hz (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Typical Steadiness of Siren Siren #315; 4T&4B Facing Mic Arrary; f= 576 Hz PMi I611 140 139 138 137 136 135 134 133 132 1131

  • 130 129 128 127 126 125 124 123 122 121 120 0

20 40 60 80 100 120 140 160 160 200 220 240 260 280 Time Iseconds]

Figure 14-4. Time History of Each SPL for Each Microphone in the Array during the Sounding of Siren 213 f = 576 Hz (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Typical Steadiness of Siren Siren #213; 2T&2B Facing Mic Arrary; f = 576 Hz 140 139 1 3 8 -

137 136-135 134-133-132.

  • 131-
  • 130-U 129-9128-127-126 -

125.

124 -

123 -

122 -

121-120-0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Thne [seconds]

14-5

Figure 14-5. Time History of Each SPL for Each Microphone in the Array during the Sounding of Siren 113 f = 576 Hz (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Typical Steadiness of Siren Siren #113: iT&IB Facing Mic Arrary f= 576 Hz 140-139 -

138-137-136-135-134-133-132.

131-130-6 129-128-127-126-125-124.

123.

122-121 120-U ZU 4U OU OU 1UU lIU 14U IOU 1OU A")

du 40 iSM dw Jw JLU MU Time Iseconds]

Figure 14-6. Steady, Repeatable, and Reproducible Results from Bi-Directional Sirens (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

BI-Directional Sirens Microphone #3 Frequency = 576 Hz cS v

m

-Ja.

ci) 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 120 0

20 40 60 80 100 120 140 160 180 200 220 240 260 Time [seconds) 14-6

Table 14-1. Steadiness of Omni-Directional Siren System Measured at the Center Microphone Location (#3)

(Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

  • RUn NI*u mberlI=

"i ""*=ll Drop iJn'SPL Over SoundDuration (40B) rto04O rto045 rto046 rto047 rto063 rto064 rto065 rto069 rto07O rto071 rto074 rto075 rtol55 rto157 rtol58 rtol59 rto 165 rtol 66 rto 169 rto 170 rto171 rtol 72 rtol97 rtol98 rtol99 rto200 rto201 rto202 0.37 0.49 0.35 0.26 0.32 0.43 0.26 0.36 0.42 0.35 0.27 0.35 0.32 0.34 0.34 0.31 0.24 0.30 0.32 0.35 0.39 0.38 0.23 0.16 0.34 0.39 0.37 0.48 Min Max Avg.

0.16 0.49 0.34 14-7

Figure 14-7. Contour Map of Frequency and Time Domain of a Typical Siren Sounding (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Exampe ofSi en Frqec Vaiaio f = 576 Hz 700 1

lDo z

U41 495

__j Tim is)

'FE"v 19 Figure 14-8. Repeatability of Acoustic Measurements on Siren #331; Microphone #3 Data (Run 46 Sounding Started After Start of Data Collection)

(Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Siren #331 Level Variation Microphone #3 Frequency = 576 Hz I.

C U

0.

U) 136 136 134 133 132 131 130 129 128 127 126 126 124 123 122 121 120 0

20 40 60 so 100 120 140 1WS 180 200 220 240 26D Time [seconds]

14-8

Figure 14-9. Repeatability of Acoustic Measurements on Siren #113; Microphone #3 Data (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Siren #113 Level Variation Microphone #3 Frequency 576 Hz 135"

!34.

133-132.

l 131 -'J 130" S129.

On 128-127

126,

-Run ria1ft; lOM2 7

  • Run rol~ll*10/2"#7 0

0 0u0n0 r12t10 1

710 180 20/

2 2

6 125 I

M ur 124-R t

i f

i n

MeTa m

on ire2n 35 Run rk)198. 10/24107 1 23R R

oRunrrttfV

. 10 D2 a e 3/7 122.

Panfrt20. 10124M07 SireRunn31 L v; V1a24rai 121.

0 20 40 s0 o 8D lO 120 140 1o I SO 200o 220 240 280 Time [seconds]

Figure 14-10. Repeatability of Acoustic Measurements on Siren #315; Microphone #3 Data (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Siren #315 Level Variation Microphone 03 Frequency = 576 Hz 136 135 134 133 132 R

d13t1 1 3D 121 120 M.

126

-Run rtoO0W; 10117JD7 C -j 125 17 reru fro070; 1I/17IDI L.

ý.

Run do0T;G?1;1177 124 Run rto074; I0W17,07

-Run rtoDS; 10/17,07 123

-FRbn r10078; 10T17 71 7

122 121is i

120 0

20 40 60 80 100 120 140 160 160 z20 220 240 2w Time [seconds]

14-9

Figure 14-11. Repeatability of Acoustic Measurements on Siren #213; Microphone #3 Data (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Siren #213 Level Varation Microphone #3 Frequency= 576 Hz 136 136.

134.

133.

  • ,132.

O. 131-130.

121 1iRun rlol[6:10c22n07 124

- 1R2un reop i

yt; 10)2Ws0l f

123

(

Run r Ro1 C8 R10e'2We7 122,_

u MS;IWM 1 21,

120, 0

20 40

6) 80 100 120 140 te0 180 2W0 22D 240 260 Time [seconds]

Figure 14-12. Outdoor Siren Repeatability "Test Results from 2007 (Source: BRRC Final Report Dated 8/07)

I Sie Oupu Repatbiit dBC Siren #

1st Test 2nd Test 3rd Test 4th Test Range Omni Sirens 102 113.9 114.1 0.2 213 111.3 111.6 111.1 110.9 0.7 369 114.1 113.3 0.8 329 113.6 112.6 1

336 114.3 113.8 113.2 1.1 BI-Directlonal Sirens 116 116.1 115.9 0.2 120 115.5 115.8 0.3 Note: all measurements in dBC on axis Enfefgy 14-10

Figure 14-13. Reproducibility of Omni-Directional Sirens Tested in Anechoic Chamber in 2007 (Source: GTRI Report D5600 - Vol. 1 Dated 3/08)

Speaker Pair Repeatability Omni Sirens; Microphone #3 Standard Deviation = 0.9 dBC 1340 138 0

136 134 132

130, S

128.

COD 126,.......

1240 A

Siren #

31 122.

46*ý"

Siren #315 120.

iren #213 Fiur 118. O Siren#113

(

r6:

R FMean 114,Q 2 B 2

=-dBC 11210 0

2 4

6 a

10 12 14 16 18 20 22 24 26 28 30 Figure 14-14. Outdoor Siren Reproducibility Test Results from 2007 (Source: BRRC Final Report Dated 8/07)

I~~

Sie to SieOtu 12 OmnLqi-n#

d8C 215 114.2 220 113,5 241 113.7 102 114.0 11 113 (Omni 2) 115.3 103 114.7 226 113.9 403 113.4 413 1144 11 312 1139 369 113.7 339 1152 329 1131 347 114.2 105 331 (Omni 1) 114.0 0

5 10 15 20 336 113.8 213 (Onmm 3) 111.4 When measured at elevated height on axis at 100 feet outdoors 14-11

14.2 Siren Performance Testing This section of the design report describes the extensive testing of sirens conducted at the Georgia Tech Research Institute (GTRI) in Smyrna, Georgia. Testing was conducted both within the GTRI anechoic chamber and outside in an open field. The results presented here are provided in more detail in two reports from GTRI.

A total of sixteen (16) Acoustic Technologies, Inc. (ATI) sirens were tested including fourteen omni-directional sirens and two bi-directional sirens. Of these, four of the omni-directional sirens and both of the bi-directional siren speakers and amplifier boards had been installed within the IPEC EPZ and were removed and shipped to GTRI for these tests. The remaining ten omni-directional siren components were acquired new from ATI for these tests.

The ten new sirens were all tested first in the anechoic chamber at GTRI. Then three of these new sirens were selected to be tested outside along with six sirens that had been installed in the EPZ.

Anechoic Chamber Testing The testing protocol for the anechoic chamber tests followed the same procedure as described in section 14.1. The same cruciform microphone array as shown in Figure 14-1 was used for the measurements. The test plan called for sounding each omni-directional siren with each set of horns facing the microphone array in turn.

The results from these tests show that the new sirens behave similarly to the sirens that were removed from poles and tested in the anechoic chamber (section 14.1). Typical results for these tests are shown in Figure 14-15 which shows selected time histories of soundings for all ten new sirens. Table 14-2 shows the sound pressure level results for the ten new sirens in the chamber.

The sirens were steady, and the results were repeatable from test to test. In addition, the sound pressure level results from the new omni-directional sirens were in close agreement with the results from the previous testing of existing sirens (see Section 14.1).

14-12

Table 14-2. Summary of Test Results from Anechoic Chamber Tests of the New Omni-Directional, Sirens (Source: GTRI Report D5600 - Vol. 3 Dated 3/08)

Siren #

Orientation Test #

Mic #3 Leq N-1 1 up rbo289 130.0 N-1 1 up rbo290 129.9 N-1 2 up rbo291 129.7 N-1 2 up rbo292 129.7 N-1 3 up rbo293 129.3 N-1 3 up rbo294 129.3 N-1 3 up rbo295 129.6 N-1 4 up rbo296 129.6 N-2 1 up rbo254 129.7 N-2 1 up rbo255 129.5 N-2 2 up rbo256 128.8 N-2 2 up rbo257 128.7 N-2 3 up rbo260 129.4 N-2 3 up rbo262 128.5 N-2 4 up rbo263 130.0 N-2 4 up rbo264 129.9 N-3 1 up rbo268 129.6 N-3 1 up rbo269 129.6 N-3 2 up rbo270 128.9 N-3 2 up rbo271 128.8 N-3 3 up rbo272 129.2 N-3 3 up rbo273 129.2 N-3 4 up rbo274 129.3 N-3 4 up rbo275 129.3 N-4 1 up rbo277 129.2 N-4 1 up rbo278 129.1 N-4 2 up rbo279 128.9 N-4 2 up rbo280 128.8 N-4 3 up rbo281 129.2 N-4 3 up rbo282 129.2 N-4 4 up rbo283 128.7 N-4 4 up rbo284 128.6 N-4 4 up rbo288 130.0 Mic #3 Siren #

Orientation Test #

Leq N-5 I up rbo298 129.7 N-5 2 up rbo299 129.8 N-5 3 up rbo300 129.6 N-5 4 up rbo301 129.6 N-6 I up rbo303 130.5 N-6 2 up rbo307 129.8 N-6 3 up rbo309 129.6 N-6 4 up rbo3l0 129.4 N-7 I up rbo3l2 127.8 N-7 2 up rbo3l3 129.8 N-7 3 up rbo314 129.6 N-7 4 up rbo3l5 130.0 N-8 I up rbo3l9 129.4 N-8 2 up rbo320 129.7 N-8 3 up rbo323 129.9 N-8 4 up rbo325 129.5 N-9 I up rbo329 130.0 N-9 2 up rbo331 130.0 N-9 3 up rbo332 129.7 N-9 4 up rbo338 130.2 N-10 1 up rbo343 130.2 N-10 2 up rbo344 130.1 N-10 3 up rbo345 130.2 N-10 4 up rbo346 129.9 N-10 1 up rbo348 130.4 N-10 1 up rbo349 130.3 N-10 1 up rbo350 130.2 Outdoor Testing The outdoor tests at GTRI's outdoor testing facility were performed to corroborate the predicted sound pressure level at 100 feet from the anechoic chamber using a steady microphone as well as a moving microphone which followed the ANSI standard S12.14-1992 for the purpose of

,comparing both valuesL' This testing was augmented with the use of additional microphones at various heights and distances.

The test site was located on the premises of GTRI in Smyrna, Georgia. It is an elongated field (approximately 200 ft by 600 ft in extent) used for radar range testing. Figures14-16a and 14-14-13

. ~1 6b show this field from an aerial vantage point and show its location relative to Dobbins AFB and surrounding commercial real estate. The western end of the field was surrounded by trees (mostly pine) at a height of approximately 75 ft or higher. A pole was installed and the sirens were mounted at this end of the field. The opposite end of the field opened up over generally flat terrain. A radar tower stood in this end of the field. The radar tower was approximately 500 feet from the pole, and the field was covered with grass.

Each siren was mounted on top of the 50 foot pole using the same brace that was used in the anechoic chamber tests. The brace was designed so that the entire siren assembly could be rotated on top of the pole to allow testing in all speaker orientations. For the six EPZ sirens, a similar cruciform microphone rig using five microphones, instead of the nine used in the chamber, was used in the field and was mounted 18.5 feet from the sirens. There were two microphones placed at 100 feet from the siren at 50 feet above the-ground. One microphone was held steady on the siren axis. The second microphone was scanned in accordance with the methodology recommended in ANSI S12.14-1992. The scanning motion was performed either manually or by using a mechanical rig. For some of these tests there was also a microphone at 200 feet (50 feet off of the ground) and for some of the tests a microphone was placed at 400 feet (50 feet off of the ground). In addition, there were also two microphones placed 5 feet off of the ground at 100 feet, and for some tests, at 200 feet from the siren. Figure 14-17 shows the arrangement of the microphones.

The results from these field tests corroborate the results from the previous anechoic chamber.

However, the average of the results from the field test suggests that the sound pressure level of the sirens at 100 feet is closer to 115 to 117 dBC (based on the stationary and moving microphone method outlined in ANSI S12.14-1992). This difference is likely caused by the addition of sound gained from the combination of the direct sound from the siren and the ground reflection. Table 14-3 lists the sound level results from all of the omnni-directional siren tests. It should be noted that favorable propagation conditions on the last two days of testing appear to have increased the measured sound on those days.

14-14

Table 14-3. Bulk Results from the Testing of the Omni-Directional Sirens (Source: GTRI Report D5600 - Vols. 2 and 3 Dated 3/08)

Stationary Mic Moving Moving Mic Test Condition/

Date Siren #

Ambient Temp (F)

Humidity (%)

Leq @100' Mic Leq @

Max Leq @

I (dBC) 100' (dBC) 100' (dBC)

Configuration 11/8/2007 331 61.5 48 114.7 117.9 120.6 1T;1B 331 62.6 48 116.3 115.9 119.1 1T;1B 331 67.9 48 116.3 115.3 119.1 2T;2B 331 59.6 48 116.0 115.4 119.4 3T;3B 331 56.3 50 117.3 112.5 118.1 4T;4B 11/9/2007 213 65.2 50 116.5 115.9 116.4 1T;1B 213 65.2 50 117.2 115.2 119.0 1T;1B 213 62.3 50 118.1 116.5 119.9 2T;2B 213 60.7 50 118.3 115.9 120.6 3T;3B 213 59.2 50 116.9 116.1 119.0 4T;4B 11/27/2007 315 61.4 45 117.2 116.5 120.0 1T;1B 315 57.6 45 115.4 117.7 119.9 2T;2B 315 51.5 45 114.8 117.0 119.9 3T;3B 315 49.2 45 112.9 116.2 119.5 4T;4B 315 55.1 45 114.2 117.3 120.0 1T;1B 315 55.2 45 113.6 117.4 120.6 1T;1B 113 63.4 50 114.8 115.3 119.5 1T;1B 113 63.5 50 114.5 115.5 119.0 2T;2B 113 59.2 50 115.4 115.7 118.3 3T;3B 113 57.7 50 114.5 115.3 119.7 4T;4B 12/1912007 N2 49.0 65 114.4 118.7 121.2 1T;1B N2 49.0 65 115.3 118.3 121.2 2T;2B N2 49.0 67 114.3 118.4 121.2 3T;3B N2 49.0 74 113.9 118.1 120.9 4T;4B N3 49.0 75 114.3 117.8 120.1 1T;1B N3 49.0 76 114.7 118.0 121.0 2T;2B N3 48.0 76 114.7 118.1 120.8 3T;3B N3 48.0 76 114.3 118.0 120.7 4T;4B 12/20/2007 N4 48.0 92 115.4 117.1 120.3 4T;4B N4 49.0 90 115.4 117.3 119.9 1T;1B N4 50.0 89 114.8 117.4 120.6 2T;2B N4 50.0 87 113.2 117.4 120.4 3T;3B As the distance between the microphone and siren increased, the sound became more variable over time. Figure 14-18 shows the results of the testing of siren 331.

In this plot, all of the microphones are kept steady, but as the distance between the microphones (receptor) and the siren increases, the variation in recorded sound level also increases. This increase in variation is due to 'unmeasured changes in the micro-meteorological conditions and is an expected result of outdoor testing.

In addition to the testing of the omni-directional sirens, two bi-directional sirens were tested.

The anechoic chamber datai agrees well (within 2 dB) with the outdoor data at 18.5 ft and the 14-15

prediction at 100 feet using a steady microphone. The measurement shows that on average, the bi-directional sirens measured approximately 118 dBC at 100 ft.

Figure 14-15. Representative Time Histories of Anechoic Chamber Data Showing Steadiness of All Ten New Omni-Directional Sirens (Source: GTRI Report D5600 - Vol. 3 Dated 3/08) 140 135 130 125 120 115 110

' 105 4

10o 95 70

-Siren N2 85 -

Siren N6 80 -

Siren N4 S75

-Siren N5 70

-Siren N6 65

-==*Siren N7 60

-Siren N8 55

  • SrnN 50 Siren N10 45 40 0

50 100 150 200 250 Time rSecondsl 14-16

Fioure 14-16a. Aerial View of Outdoor GTRI Test Site irpA 1-l~h CMn~ar AnriaI viaw nf fliitrlnnr.TRI Tact Qita 14-17

Figure 14-17. Schematic Showing Relative Measurement Locations at the GTRI Outdoor Test Site (Source: GTRI Report D5600 - Vol. 2 Dated 3/08)

Grass Figure 14-18. Variability in Measured Sound Level with Increases in Measurement Distance (Source: GTRI Report D5600 - Vol. 2 Dated 3/08)

C4 Cý CL U) 134 132 130 128 126 124 122 120 118 116 114 112 110 108 106 104 102 100 0

50 100 150 200 250 Time [seconds]

300 14-18

14.3 Acoustic Coverage in the EPZ.

The design objective of the installed siren system is to provide full acoustic coverage for the populated sections of the IPEC EPZ in compliance with FEMA guidelines. A siren output of 114 dBC Leq (omni-directional) and J116 dBC Leq (bi-directional) both at 100 ft. on axis at siren elevation was utilized, although as explained below this is a conservative approach based on actual measured sound output.

GTRI conducted independent acoustic testing of the IPEC ANS sirens. Six sirens installed in the new system within the IPEC EPZ were removed from their respective poles and delivered to GTRI in addition to ten new sirens. The siren acoustic testing at the GTRI facilities included two separate programs: anechoic chamber testing and open field testing.

Testing of the 14 omni-directional and 2 bi-directional sirens in the anechoic chamber resulted in an average of 115 dBC Leq for the omni-directional sirens and an average of 117.3 dBC Leq for the bi-directional sirens both projected at 100 feet. In the field testing at GTRI, results showed up to 2 dBC higher measurements than predicted in the anechoic chamber, with the actual numbers of 115.2 to 117.4 dBC Leq for the omni-directional and 116.7 to 11 8.7dBC Leq for the bi-directional sirens. Furthermore, the Lmax readings in the field, determined after the initial transient response from the sirens, showed at least an additional 2 to 3 dBC higher sound pressure level, ranging from 119 to 121 dBC Lmax.

A statistical analysis was performed utilizing 52 independent speaker pair measurements that were taken in the GTRI anechoic chamber. The mean sound pressure level of the sample population was 115 dBC Leq with a standard deviation of 0.5 dBC. Using both a Chi-Squared and a Student T analysis, the minimum siren level output, at the 95% confidence level, for any siren in the total population is 114 dBC Leq. Therefore, to provide sound coverage margin, a conservative siren output level of 114 dBC Leq was used in the sound contour model, notwithstanding the fact that the actual output was measured at higher values.

FEMA-REP-10 specifies that the siren sound pressure level should generally exceed 70 dBC where the population density exceeds 2000 people per square mile in the EPZ. In areas with a population density below 2000 people per square mile the siren sound pressure level should generally exceed 60 dBC.

The ATI model demonstrates that the 70 dBC sound output criterion is met in high population areas requiring 70 dBC coverage. The 60 dBC sound output criterion is met in low population areas requiring 60 dBC coverage with the exception of four small areas in the EPZ that are sparsely populated or unpopulated (mostly parkland) and largely inaccessible. Though these areas project to be less than 60 dBC, the one area in Putnam County where population resides was actually measured to have a sound pressure level of 62 dBC. Thus, there is minimal effect on the notification of residents of the EPZ.

Additionally, Blue Ridge Research and Consulting (BRRC) performed an ambient noise survey in high population density areas in thirteen locations within the EPZ for three consecutive days in August of 2007 to determine the outdoor summer daytime ambient sound level in areas within the EPZ. ýThe daytime (7 AM to.10 PM) noise data from these measurements was used to compute:the local ambient noise environment. The exceedance levels of L10, L50, and L90 were computed in the 2 8 th third octave band, centered on 630 Hz. The L90 levels, representative of the ambient background sound levels, ranged from 25 dB to 46 dB. The L50 levels, representative of the average sound conditions, ranged from 28 dB to 59 dB. The Li 0 14-19

levels, representative of the infrequent and transient noise intrusions, ranged from 35 dB to 52 dB. Complete details and results from the survey are provided in Appendix C.

The measured sound pressure levels from the siren full sounding in the far field exceeded the L50 value (which is most representative of average background conditions) by 15 to 30 dBC in the third octave band.

The siren sound level coverage is provided on Map 2. The map indicates areas with 60 dBC and 70 dBC coverage and the population density in the EPZ.

Based on the sound contours presented in Map 2, IPEC concludes that the siren system as designed meets or exceeds FEMA-REP-10 guidance for sound pressure levels and population coverage.

14.4 Far Field Measurements Methodology The purpose of the measurements described herein is to characterize the amplitude of sound produced by the complete siren system around the Indian Point Energy Center. The results from these measurements will be compared with the results from the model developed by ATI to confirm the quality of the prediction reflected in the ATI model.

Equipment ANSI certified Type 1 Sound Level Meters (SLMs) will be used in the measurements as per ANSI S12.18. Before and after each measurement the calibration of each sound level meter will be checked, and the calibration tone will be recorded for at least 30 seconds. Each sound level meter will be capable of recording noise data at one-second intervals. The SLMs will be set to record the C-Weighted values. The 1 second Leq and the 1 second third octave band data will be recorded wherever possible based on equipment availability. Each SLM microphone will be fitted with a wind screen and will be mounted on a tripod or other suitable firm mounting device at a height of approximately 5 feet above ground level. Each SLM clock will be synchronized with the clock used to initiate the siren test. In addition, meteorological data will be collected including wind speed and direction, temperature and humidity within the EPZ. Multiple locations within the EPZ will be used to collect this data for each full siren test and recorded at the highest possible sample rate.

Measurement Locations Twenty (20) measurement locations will be selected within the EPZ. Locations of interest will include: areas along the sound contour lines: areas downwind, cross wind or surrounded by sirens; areas of challenging topography; high population density areas and those locations previously identified with potentially lower projected sound levels, where additional sirens were added. Each measurement position should be greater than 50 feet from the nearest reflecting surface such as buildings, boulders, walls, and other obstacles. General guidelines for selecting measurement locations are that the measurements should be greater than 1,000 feet from the nearest siren. The precise location of each measurement location with GPS coordinates will be determined and recorded, together with any additional details about the measurement location.

Also locations that have been previously identified as being within the shadow created by a co-located siren should be avoided. Multiple test days will be planned to maximize the opportunity 14-20

to have the appropriate weather conditions for testing. Test day weather conditions will be factored into the correlation of predicted to measured sound pressure levels.

Measurement Procedure The SLMs will start recording data approximately 2 minutes or more prior to the full system sounding and will continue to record data for approximately 2 minutes or more after the siren sounding has concluded. The testing personnel should be careful not to make any noise during the period while the SLM is running including the periods prior to and after siren sounding while the SLM is operating.

Each operator of an SLM will be given a data sheet (Figure 14-19) that will be filled out completely. Each data sheet will have all of the information about the test including the date, time, location, SLM serial number, and calibration. In addition, the operator will record the local ambient noise level before and after the siren system sounding. Each operator will note on the data sheet any significant intruding noise sources that occur during the test. This is intermittent noise that is above background. The operator will record the source and time of the intrusion on the data sheet.

Testing will not be conducted if meteorological conditions such as precipitation and elevated wind exist. ANSI S12.18 provides guidelines for appropriate atmospheric conditions. Every effort will be made to collect data under the conditions stated in ANSI S12.18. The determination to take measurements will be made by the Test Director on the day of the test.

Data Analysis The data from the SLMs will be analyzed to determine the sound level produced during the full siren system activation. The third-octave band with the majority of the siren energy will be identified and used for part of the analysis, including the difference above ambient. Data will be reported by identifying the C-weighted Lmax (maximum 1 second Leq during the test) and the C-weighted L10. In addition, the complete time history of each measurement will be recorded.

Comparison with Modeled Results The measured metric, C-weighted Li 0, will be compared to the output from ATI's sound propagation model. Lmax will be reviewed for a more complete understanding of additional margin. For this analysis, the sound level predicted by the model will be compared with the measured L10 at each location. To evaluate the quality of the sound propagation model, the data will be analyzed by a bulk average deviation method as shown in Eq. 1 below.

Any significant outlier will be identified and considered. If there are extenuating circumstances that are identified and justify exclusion, these outliers will be removed from the bulk average calculation. Examples of outlier circumstances include: siren material condition, instrument problems, interfering noise events, etc. An outlier is defined as a measurement greater than 3 standard deviations of the difference in predicted and measured sound pressure level data. Any exclusion will be documented.

14-21

(Eq. 1)

Q = y (Pi-Mj)

N Where:

Q is the measure of model quality Pi is the predicted Leq sound pressure level at the ith location Mi is the measured Leq sound pressure level at the ith location N is the total number of measurements A value for Q of positive 3 dBC or less is indicative of a high level of model quality. Since this is a one-sided test any negative value of Q is acceptable, since that means the measured values are predominately higher than the predicted and thus the model would be conservative.

14-22

Figure 14-19.

Indian Point Siren Test Sample Data Sheet Date:

Time:

SLM Model:

SLM Serial Number:_

Tester's Name:

Measurement Location:

GPS Coordinates:

West North Checked Battery?

Yes No Checked Clock?

Yes No Calibration level before test:

dBC 30 second calibration tone recorded before test?

Yes No Calibration level after test:

dBC 30 second calibration tone recorded after test?

Yes No Calibrator Model:

Calibrator SN:

Location Drawing:

Microphone height:

ft.

Taken Photo?

Yes No Meter Recording?

Yes No Weather Station on and wind cover removed?

Yes No Ambient noise level before test:

dBC Maximum level observed during the test:

dBC Ambient noise level after test:

dBC Notes about test (including noise intrusions):

Tester's Signature:

14-23

15 BACKUP POWER Twenty-four hour battery capability is provided to meet the backup power requirements of the Energy Policy Act. The design includes this capability for each siren (Remote Terminal Unit or RTU), each control station and one of the redundant radio paths (Repeater Towers). Twenty-four hour battery backup capability is also provided for the second redundant radio path and the TCP/IP equipment installed at the sirens, control stations and repeaters, with the exception of the T1 telephone lines and the TCP/IP network, which are maintained by Verizon (Telco).

Sirens (RTU)

Each of the 167 siren/control panels contains a 24V DC battery system for normal operation of the electronics, radio transceiver and cell/modem transceiver. The typical installation consists of four 12V DC maintenance-free gel-type batteries connected in a series/parallel configuration to provide for 24V DC operation (the 7 solar installations each use 8 batteries). The total number of batteries provided to meet the power requirements are based on a worst case assumption of a temperature of zero degrees F, end of battery life, a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> standby period (without recharging) and a 15-minute activation of the siren.

For the 160 sirens receiving utility power, a built-in rectifier/charger converts the input 120V AC to 24V DC, to float charge the batteries which provide DC power to the respective siren power units. The remaining 7 sirens are solar powered and have a photovoltaic charge controller to float charge the batteries. Upon loss of the normal AC input power (or solar charging), the batteries will continue to supply DC power to the respective circuitry with no interruption of DC power to the siren pole circuitry. Following discharge of the batteries, the chargers connected to the 120V AC supply have the capability to recharge the batteries to 80% capacity within 24-hours. An alarm message is initiated and the batteries will continue to supply power for the specified time whenever the normal AC input power source (or solar charging) to the rectifier/charger deviates from the specified tolerances or fails completely. Both types of chargers are temperature compensated for the system to operate in a harsh outdoor environment.

The battery compartment on the AC supplied sirens is fitted with a battery compartment heater and thermostat which are powered from the line voltage of the incoming source.

Control Stations Each of the control stations contains an Uninterruptible Power Supply (UPS) unit that provides 120V AC power for normal operation of the electronics, radio transceiver, cell modem transceiver, a computer work station and a printer. The UPS unit normally receives power from the utility grid and is provided with an external connection to a 24V DC battery system for backup power. The typical battery installation consists of eight 12V DC maintenance-free gel-type batteries connected in a series/parallel configuration to provide for 24V DC operation. Eight batteries are provided to meet power requirements for a 24-hour standby period (without recharging), and the power required to support periodic polling, silent tests and monitoring of the system at end of battery life.

Following discharge, the battery charger incorporated within the UPS units has the capability to recharge the batteries to 80% capacity within 24-hours. An alarm message 15-1

is initiated whenever the normal AC input power source to the rectifier/charger deviates from the specified tolerances or fails completely.

The Orange County FOC has additional battery chargers, batteries and 12V DC systems for the remotely located radio transceivers that are sized to meet the same requirements.

The control station cabinets are located in facilities with heating and air conditioning so that the battery capacity requirements do not need to be adjusted to account for low temperature conditions.

Repeater Towers Each of the four Repeater Towers enables communication to the control stations and siren pole locations via VHF radio with coordination (simulcasting) between the towers, linked by Telco "Ti " line or microwave. Dual sets of equipment are provided in racks for the redundant microwave and Telco channels and are powered from two separate UPS units (one for the microwave path and the other for the Telco Ti path). The UPS units normally receive power from the power grid and are provided with an external

'connection to the 24V DC battery systems for backup power. The typical battery installation consists of twenty four 12V DC maintenance-free gel-type batteries connected in a series/parallel configuration to provide for 24V DC operation. Twenty-four batteries are provided to meet the power requirements of a 24-hour standby period (without recharging), and the power required to support periodic polling, silent tests and monitoring of the system, at worst case temperature of zero degrees F at end of battery life. To conserve power, automatic load stripping is provided to de-energize the main radios and access server, and filters on the channel that is not in service when normal AC power is not available. A separate AC power supply is also provided for the monitoring unit electronics that provide for monitoring system status using a separate radio and Internet/Cellular radio. The battery system also provides backup power to the monitoring unit.

Following discharge, the battery chargers incorporated within the two UPS units, two separate battery chargers and a charger in the Monitoring Unit have the capability to recharge the batteries to 80% capacity within 24-hours. An alarm message is initiated whenever the normal AC input power source to the rectifier/charger deviates from the specified tolerances or fails completely.

With the exception of Harriman, the repeater locations are all located within facilities with heating and air conditioning. The Harriman repeater enclosure itself has a thermostatically controlled space heater and air conditioning which is AC powered.

There is one communications channel (the radio/microwave channel) for the 'repeater towers that has battery power supplies confirmed to provide 24-hour backup power in the event of a loss of normal AC power.

15-2

16 FAILURE MODES AND EFFECTS ANALYSIS A Failure Modes and Effects Analysis (FMEA) of the new IPEC Prompt Alert and Notification System was performed to identify failure vulnerabilities. This analysis is documented in the report entitled "Failure Modes and Effects Analysis (FMEA) of the New Siren System for Indian Point Energy Center." The recommendations of this analysis were entered into the IPEC corrective action program for evaluation and consideration for implementation. The analysis was based on system testing, review of drawings, design reports, contract and vendor documents and discussions with IPEC and contractor staff.

FMEA Methodology FMEA is a methodology for analyzing potential reliability problems and identifying actions to overcome these issues, thereby enhancing reliability. FMEA is used to identify potential failure modes, determine their effect on the operation of the system and identify actions to mitigate the failures. This is a crucial step in anticipating what might go wrong with the system. The FMEA development team formulated an extensive list of potential failure modes using military guidance MIL-STD-1629, MIL-STD-882 and MIL-HDBK-217.

This analysis was set up in three categories:

System Category-focuses on global system functions (such as activation, and routine operations of polling, monitoring, and control)

Design Category-focuses on components and subsystems Software Category-focuses on software functions For each of the above listed categories, spread sheets were populated with the components, functions, or items. For each of these, potential failure modes were identified; potential effects and their severity were discussed; potential causes were listed; and system failures and means for detecting those failures were identified.

Design controls to mitigate failures were then evaluated and recommendations to minimize or detect failures were provided.

The analysis calculated a Risk Probability Number (RPN), which is the product of the three terms evaluated during the FMEA. The Severity (S) of the potential effects of failure, the probability of Occurrence (0) of the failure, and the ability to Detect (D) the failure. RPN = (S)*(O)*(D). The bounds of the RPN are therefore from a minimum value of one (1) to the maximum of one thousand (1,000). The larger the value of RPN, the more critical it becomes to evaluate that process or component under analysis. Actions and process changes to mitigate issues with elevated RPN were recommended.

Six FMEA functional areas were prepared as follows:

System Category Single Occurrence Process (Functional Area 1):

The analysis contained within this section addresses the potential failure modes arising during a required full Alert Notification System activation. The system-wide objectives analyzed are: first, the physical sounding of the sirens at their field locations and second, the subsequent reporting of the post activation status of those sirens.

16-1

Continuous Operational Processes (Functional Area 2):

The analysis contained within this section addresses the routine operation, control and functions and capabilities of the Alert Notification System and includes polling (including queries of control stations), silent tests, growl tests, full volume tests, monitoring and external notification.

Design Category Component Level Analysis:

The analysis contained within this section addresses the potential failure modes of each component and their affects on activation, control and monitoring of the siren system.

Separate spreadsheets were prepared for the Sirens (Functional Area 3), Control Stations (Functional Area 4) and Simulcast Towers (Functional Area 5).

Software Categqory Software Applications Processes (Functional Area 6):

The analysis contained within this section addresses software programs used at the control stations, simulcast towers and the sirens for activation, monitoring, and testing.

FMEA Results Summary Overall, the FMEA review concluded that the design provides redundant and distinct communication paths for activating the siren system and monitoring results and that the system will be able to provide alert notification when required. The design incorporates a high level of features for self-monitoring of the system and for conducting routine testing to confirm that communication channels are operating satisfactorily or to report problems. The review also concluded that multiple failures would have to occur for the system to be unable to activate sirens when needed. Typically, all of the control stations and sirens are capable of being polled regularly during the day, unsolicited alarm messages are provided for major component failures at the simulcast towers, sirens and control stations, and alarm messages are generated for communication path failures.

Loss of normal AC supply power at each location and siren system communication failures are reported externally to station personnel.

There is one communications channel, including control station, repeater tower, and sirens, that has battery power supplies credited for being capable of providing power for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on loss of normal AC power.

For each of the areas where potential failures were identified, recommendations, such as to conduct automatic routine polling of control stations and sirens and to review computer logs for results, were made to detect any failures that may have occurred and confirm that the system is in a ready state. Additionally, maintenance activities were identified to minimize potential failures, or additional testing or monitoring was recommended if there could be hidden problems that may not be identified by routine testing, thereby ensuring high system reliability to activate the sirens and verify their activation. Recommended maintenance activities were captured in the corrective action program to track implementation of these activities.

1 6-2

17 CONFIGURATION MANAGEMENT The objective of configuration management is to maintain consistency between the design requirements and the physical siren system installation arrangement (as-built).

Procedures controlling the process for documenting as-built conditions, evaluating the need to change siren system configuration, determining the impact of the change and completing the necessary development and approval steps to produce an approved, implemented and documented change to the siren system are identified below. This ensures that information necessary to construct, operate and maintain the siren system so that it will continue to meet regulatory requirements is controlled and managed.

Walkdowns, testing, inspections and assessments have been performed to document and create a permanent validated record of the system configuration.

IPEC has various procedures in place to control configuration changes to the siren system. Descriptions of the procedures in place at time of report writing are as follows:

EN-DC-1 12 - "Engineering Change Request and Project Initiation Process" This is a fleet standard engineering change and projects procedure which defines the process for initiation, funding, resources and approval.

EN-DC-1 15 - "Engineering Change Development' will work together with EN-DC-1 12 and will govern the preparation, review, approval and processing of an Engineering Change. The scope of the work to be performed is defined pursuant to this procedure.

EN-DC-1 16 - "Engineering Change Installation" applies to and defines the installation phase of the Engineering Change.

EN-DC-1 17 - "Post Modification Testing & Special Instructions" is applied after the Engineering Change is installed. This procedure gives guidance for functional testing to verify that objectives of configuration changes authorized by an Engineering Change are satisfied and/or verify required performance of associated equipment that may have been affected by the configuration change.

EN-DC-1 18 - "Engineering Change Closure" establishes the requirements and responsibilities for the Return to Service, Post Return to Service and Closeout of the Engineering Change including verification and documentation of the as-built configuration.

EN-WM-100 -Work Request Generation, Screening and Classification" is the procedure that governs the generation, screening and classification of work requests for changes to the siren system.

IP-EP-AD31 - "IPEC ATI Siren System Maintenance Administration" is the IPEC Emergency Plan Administrative Procedure which is used to provide guidance for the inspection and maintenance of the siren system. If deficiencies are found while performing IP-EP-AD31, appropriate action will be determined to correct or install the required components while maintaining configuration of the siren system.

EN-IT-104 - Software Quality Assurance (SQA) Program will govern and control software/firmware upgrades to the siren system and ensure that they have been thoroughly reviewed and tested before being installed and implemented.

All changes to the approved, as-built siren system will be documented and controlled following the above mentioned procedures as appropriate for a commercial modification.

17-1

18 SYSTEM TRAINING Operator Training The training familiarizes the user with basic functions of the system. Personnel responsible for operation of the system receive training covering the following topics:

" Characteristics and capabilities of the system

" Tour of the graphical user interface

  • Procedure for testing the system

" Procedure for performing an alert

" Procedure for resetting the system after an alert has occurred

" Powering the control stations and starting the application

" Understanding system status

  • Understanding system reports
  • Using a control station to work as a backup to other control stations A lesson plan and handouts have been prepared to conduct this training.

Maintenance Training The training familiarizes the user with maintenance and troubleshooting of the system.

Personnel responsible for maintaining the system receive training covering the following topics:

" Recommended test schedule

  • Preventive maintenance schedule
  • Maintenance report and error log analysis

" Troubleshooting basic communication problems

" Troubleshooting basic hardware problems

  • Troubleshooting basic software problems

" How to change field replaceable units 18-1

19 SYSTEM OPERATIONS, TESTING AND MAINTENANCE PROCEDURES The procedures referenced below are procedures in place at time of report writing.

System Operations Procedures IPEC Procedure IP-EP-AD32 establishes the methods required to perform routine testing of the siren system. The procedure provides details on how to conduct a silent test, growl test, and full volume test, and polling of the system.

An Indian Point Alert Notification Siren System manual has been prepared for each county which provides detailed instructions on how to activate, test, and poll the system.

This manual also provides log in instructions, instructions for sounding sirens/cancelling activation from the computer and the REACT-4000, instructions for sounding other sirens/canceling activation from the computer, and printing reports. The manual contains color screen shots of the computer to facilitate the operation of the system.

Additionally, operator aids containing abbreviated instructions have been provided to each county for display at each siren control station.

System Testing Procedures IPEC Procedure IP-EP-AD30 establishes the administrative controls for the routine conduct of testing, test scheduling and coordination, test result reporting, and monitoring of the siren system.

This procedure also provides examples of typical annual siren test schedules, sample siren test plans, guidelines for siren system quarterly and annual testing, system periodic testing, and sample siren test reports.

System Maintenance Procedures IPEC Procedure IP-EP-AD31 provides guidance for the maintenance of the siren system.

This procedure discusses the preventive and corrective maintenance performed on the system.

Preventive maintenance is performed in three (3) areas: sirens sites, control stations, and tower repeater sites. This procedure details quarterly maintenance, semi-annual maintenance, and annual maintenance and provides checklists for each.

The siren system preventative maintenance program consists of:

  • Visual inspection of the siren site which includes all external components and their mounting and connections (speakers, cabinet, and antenna, solar panels) pole integrity, grounding, foliage encroachment, and utility AC power feed.

Internal inspections of each speaker and cabinet are performed to look for corrosion on components as well as verification that all connections are tight and 19-1

properly seated. Incoming AC power (not on solar), charger voltage (or solar regulator voltage) and DC battery voltage are checked and documented. Radio and cell modem operation and alarm communications are checked locally and verified remotely with the control station.

  • Visual inspection of the control station includes the external antenna and cable installation outside the building as well as the control station cabinet to look for damaged or missing components as well as dust and debris. All connections, internally on the communications unit and externally to the computer, cell modem, printer, antennas, batteries and backup power supply are checked to look for corrosion on components as well as verification that all connections are tight and properly seated. Battery voltage is measured and recorded before, during and after performance testing. AC power to the control station is disconnected and a poll and silent test of the sirens is performed and documented while under battery power. Radio and cell modem operation and alarm communications are checked and verified.

Each control station computer is re-booted quarterly to ensure that no software or operational processes are in a "hung-up" state. Data network lines provided by commercial carriers are analyzed periodically for network errors.

" Visual inspection of the tower repeater site includes the external antennas, microwave dish and cable installations outside the building as well as looking for damaged or missing components. The general condition of the repeater racks are noted for dust, debris and any loose, broken or missing hardware. All connections to equipment in and between the racks are checked for corrosion on components as well as verification that all connections are tight and properly seated. Battery voltage is measured and recorded as well as battery charger output voltage. Repeater components are monitored for proper operation and any alarming conditions during the performance of a siren poll and silent test.'

Corrective maintenance will be performed to remedy conditions identified during routine monitoring of the system.

19-2

20 SIREN SYSTEM ROUTINE TESTING Routine testing of the system will be performed from the control stations. The following will be performed as a minimum as suggested in NUREG-0654 and FEMA-REP-IO and IPEC's Failure Modes and Effects Analysis:

Routine polling will be performed to validate communications between control stations, towers, and sirens. Success will be confirmed by feedback to the control station.

A weekly test of all sirens will be initiated from a control station to ensure the transmission path and the siren audio drivers are functional. Testing will be initiated from various control stations using typical communications paths. The test makes a brief sound, which is audible to the public. The siren test checks the communication with the sirens in addition to checking the audio drivers.

Success will be confirmed by feedback to the control station.

A quarterly growl (10-second activation) test will be initiated for each siren from a control station. Success will be confirmed by feedback to the control station.

An annual full activation test will be conducted. The full activation is an alert activation, which produces 3-5 minutes tone. Success will be confirmed by feedback to the control station(s).

Additionally, the following testing will be performed:

A silent test will be performed following preventative maintenance at a siren.

Success will be confirmed by feedback to the control station.

Additional testing will be performed by each county at their discretion.

20-1

21 QUALITY CONTROL An overall quality control program has been implemented to ensure the reliability of the siren system. Elements of the program include: design (configuration) control, document control, and software control as discussed in section 17, procedure use as discussed in section 19, and inspection and testing as discussed in this Section. Existing IPEC procedures and programs'are used as applicable for many of these elements. The IPEC corrective action program is used to identify issues and track associated corrective actions.

This program has been implemented during factory testing and testing both at installation and post installation. Testing was also conducted for several siren configurations in a test lab. Additionally, a Failure Modes and Effects Analysis, discussed in section 16, was conducted to identify system vulnerabilities as part of this quality control effort.

Factory Testing ATI performed and documented acceptance tests on the Siren Cabinets (RTUs) and control stations in the factory before shipment to IPEC. The Siren Cabinet (RTU) inspection consisted of basic identification data being recorded including serial numbers, wiring diagrams, software/firmware versions, radio type and frequency used. The inspection also included checking all equipment mounting, connections and the condition of wiring to all components. The units were powered up, and a checklist was completed based on measuring and documenting speaker resistance and DC voltages at various locations within the cabinet. In addition, the board-mounted function push buttons (reset, calibration, steady tone, silent test, low power and off) were tested to verify that their respective functions performed satisfactorily with the proper illumination of their LEDs. Lastly, the installed software was tested to verify successful programming, polling and reporting of required alarms.

The control stations were tested at the factory as follows: Identifying information for each location was recorded which consists of serial numbers, wiring diagrams, software version, radio type and frequency used, wattage and DIP switch settings and battery information. The inspection included verification that all equipment connections and the condition of wiring to all components were correct. Voltage measurements were taken on the REACT-4000 circuit boards and battery voltage was recorded. REACT-4000 software was programmed and verified and then polling was performed using radio only, IP link only and both paths to ensure software performed as designed. A silent test was performed as well as REACT-4000 alarm verification for various alarm features.

Additional polling and activations were performed and documented using the software with the computer turned off and using the REACT 4000 unit only.

A factory test was performed by Microwave Data Systems (MDS) on the microwave and simulcast system for the repeater equipment located at Harriman, Grasslands, Tinker and the IPEC Met Tower. The radios and the Harris multiplex equipment were powered up per their operating manuals, and function was verified and documented. Signal

strength was measured and "end to end" radio tests were performed to verify the ability
of the radio to send tones to "key" the repeater. This was done on both the microwave and the "TI" side of the equipment. The radio system was powered OFF then ON to 21-1

verify link synchronization without triggering alarms. Also, the GPS clock signal was turned ON and OFF to verify the ability to keep link synchronization in both conditions.

Results of the factory acceptance tests were reviewed. See Appendix D for an overview of the General Factory Acceptance Test steps.

Software Quality Assurance Software Quality Assurance (SQA) was performed to provide adequate confidence that software conforms to established requirements throughout its life cycle.

The scope of the SQA inspection ensured that the delivered Alert and Notification System software component is complete, correct, and meets the specified requirements.

The inspection was conducted on the available software media, documents or other formal deliverable products.

The following SQA activities were performed:

  • Collected documentation
  • Conducted a software requirements review
  • Reviewed the relevant process documentation to ensure that evidence exists that the required procedures for software acceptance have been completed
  • Documented findings in the corrective action program
  • Reviewed the current corrective action status and the software to ensure that evidence exists that all previously noted deficiencies have been resolved
  • Verified that all deficiencies from peer reviews, and tests have been resolved Field Testing Testing at Installation ATI documented the installation and initial setup of each RTU siren cabinet in the field on a Field Checkout sheet. Siren numbers were recorded as well as firmware version loaded and radio serial numbers. The overall condition of the siren installation was checked including proper mounting of all equipment, checking wiring and connections on circuit boards, antenna connections, measurement of speaker impedances, battery voltage, charger voltage and voltage measurements on the siren boards, radio and modem. The sirens were calibrated and the unit was programmed from a REACT-4000 and verified for normal radio contact. A silent test was performed and the door switch, thermostat and heater were checked.

Control stations and repeater equipment were installed in their required locations and inspected for overall condition. All wiring and connections were inspected.

Post Installation Testing and Inspection Post installation testing and ýinspections have been performed in accordance with approved procedures. Testing included operation under degraded battery conditions, verification of polling and siren activation, and verification of alarms for loss of AC power.

This testing is further discussed in Appendix D.

21-2

Inspections have been, performed to verify that the siren system configuration and condition is acceptable prior to declaring system operability. Following installation, an independent verification 'inspection of the overall condition of the siren installation was performed which included checking the proper mounting of all equipment, checking wiring, polarity and connections on circuit boards and speakers, antenna connections, measurement of speaker impedances, battery voltage, charger voltage and voltage measurements on the siren boards, radio and modem. A silent test was then performed and the sirens were calibrated and verified for normal radio and TCP/IP contact. The door switch, thermostat and heater were also checked.

At the towers, hardware and software configuration settings as well as switch and jumper settings were documented. All wiring and connections were inspected and verified to conform to the applicable vendor wiring diagrams. Corrections to these diagrams were made based on these inspections.

The post installation inspections addressed the following:

  • The stiff speaker wiring cables in the siren control cabinet can be made more flexible by stripping back the outer cable jacket allowing connections to be maintained more reliably.

Nyogel grease should be applied to driver terminal connections to prevent corrosion.

" Silicone should be applied to the cell modem antennas to prevent water intrusion.

  • A weep hole should be drilled into the bottom of the speaker cover to prevent water accumulation inside the cover.

Local calibration and silent testing of the siren is required for successful operation.

  • Speaker wires need to be checked for correct phasing for proper sound output.

Speaker wire connectors in the cabinet need to be checked for proper contact with the wire.

" The driver and cable resistance should be satisfactory prior to performing calibration.

" The timing signals for the control stations should be connected to a national time standard.

e Siren amplifier boards should to be reprogrammed and reconfigured for the particular application.

Anomalies discovered during the testing and inspections were documented and resolved using the corrective action program.

21-3

Acoustic Testing Georgia Tech Research Institute (GTRI) conducted acoustic testing for the IPEC sirens.

This testing included both anechoic chamber and open field testing. The testing collected data to support the determination of the siren characteristics pertinent to their acoustic performance. This testing is further discussed in section 14. Results of this testing are also provided in Appendix B.

21-4

22 CONCLUSION As a result of the Energy Policy Act of 2005, IPEC elected to install a new ANS system consisting of fixed electronic sirens capable of providing an alert for twenty-four (24) hours after a loss of normal AC power. The battery backup power feature ensures system components operate securely in the event of power failure. The design of the new system also minimizes single points of failure.

The IPEC ANS consists of sirens, broadcasted emergency information, and high speed telephone notification. This system meets the guidelines set forth in the Federal Emergency Management Agency's (FEMA) regulations, 44 CFR Part 350, Planning Standard E, Appendix 3 of NUREG-0654/FEMA-REP-1, and the Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants (FEMA-REP-1 0).

The sirens were installed on steel poles which extend pole life and withstand environmental challenges. Additionally, susceptible siren wiring is protected from damage because they are installed within the metal poles.

One hundred and fifty-two (152) sirens are omni-directional and fifteen (15) use the bi-directional configuration.

The communication control system uses eleven control stations that are designed to have complete control and monitoring capabilities over all sirens in the system.

Each county has complete activation control and monitoring over the sirens used to alert its county from all control stations located within its county and can monitor the activation of all sirens via the computer display. Each county can also monitor sirens from bordering counties that may affect their county. All counties can also activate other counties' sirens if agreed upon. The two control stations at IPEC can also activate all of the sirens if needed.

Twenty-four hour battery capability is provided to meet the backup power requirements of the Energy Policy Act. The design includes this capability for each siren, each control station and one of the redundant radio paths at the repeater towers. Twenty-four hour battery capability is also provided for the second redundant radio path and the wireless TCP/IP equipment installed at the sirens, control stations and repeaters, with the exception of the T1 telephone lines and the TCP/IP network, which are maintained by Verizon (Telco).

The system incorporates reliable communication and post activation polling using radio and TCP/IP communication.

There are two separate and distinct communication paths used to convey activation and monitoring messages between the control stations and the remote sirens: dedicated redundant simulcast radio systems and a cellular TCP/IP system. The design eliminates single points of siren communication failures since multiple control stations can communicate to every assigned siren by either communication path.

The communication and control system reliability testing performed in 2007 for the microwave synchronized simulcast radio activation and control mode has demonstrated high reliability (greater than 97%) with a greater than 95% confidence. This activation and control mode has battery power supplies confirmed to provide 24-hour backup 22-1

power in the event of a loss of normal AC power. Furthermore, the testing has not revealed any unanticipated failure modes.

Acoustic testing at Georgia Tech Research Institute (GTRI) included both anechoic chamber and open field testing. The testing collected data to support the determination of the siren characteristics pertinent to their acoustic performance. The testing demonstrated that the siren output is steady, repeatable, and reproducible.

The siren sound contours of 60 and 70 dBC within the IPEC EPZ were calculated by a computer model developed by ATI. The ATI model demonstrates that the 70 dB sound output criterion is met in high population areas requiring 70 dB coverage and the 60 dB sound output criterion is met in low population areas requiring 60 dB coverage.

To further confirm the quality of the ATI predictions, acoustic measurements were also taken in the far field. These measurements were compared to the predicted sound pressure levels for these locations. A bulk average deviation method was used to analyze this data. Close alignment was shown between the predicted values and measured values using this bulk average method.

The siren system as designed exceeds FEMA-REP-10 guidance based on the sound contours generated by the ATI acoustic model using 114 dBC as siren output. Modeling indicates that sound coverage meets requirements down to a siren output of 112 dBC.

The controlled testing at GTRI showed an average siren output range of 115.2 to 117.4 dBC measured during outdoor testing. This design using a 114 dBC siren output is conservative by up to 5.4 dBC of margin.

Inspections have been performed to verify that the siren system configuration and condition is acceptable prior to declaring system operability. These inspections have ensured a high level of material readiness that will maintained through an ongoing siren maintenance program.

22-2

APPENDIX A LISTING OF ACRONYMS AC Alternating Current ANS Alert and Notification System ANSI American National Standards Institute ATI Acoustic Technology, Inc.

CAP Common Alerting Protocol CCU Communications Control Unit CR Condition Report dB Decibel dBA Decibels (A-weighted scheme) dBC Decibels (C-weighted scheme)

DC Direct Current DOD Department of Defense DTMF Dual Tone Multi-Frequency EAS Emergency Alert System EOC Emergency Operations Center EOF Emergency Operations Facility EPZ Emergency Planning Zone ERP Effective Radiated Power F

Fahrenheit FEMA Federal Emergency Management Agency FMEA Failure Modes and Effects Analysis FSK Frequency Shift Keying A-1

GIS Geographical Information Service GPS Global Positioning System HPSS High Power Speaker Station Hz Hertz IP Internet Protocol IPEC Indian Point Energy Center LAN Local Area Network LED Light Emitting Diode Leq Equivalent Sound Pressure Level Ln Sound Pressure Level exceeded n percent of the time M

Meter MHz Megahertz MPH Miles Per Hour NEMA National Electrical Manufacturers Assoc.

NRC Nuclear Regulatory Commission NRTC National Rural Telecommunications Cooperative PIP Palisades Interstate Park System RECS Radiological Emergency Communications System RF Radio Frequency RH Relative Humidity RPM Revolutions Per Minute A-2

RTU Remote Terminal Unit SAB Siren Amplifier Board SAIC Science Applications International Corporation SPL Sound Pressure Level TAR Tone Alert Radio TCP Transmission Control Protocol TCP/IP Transmission Control Protocol/Internet Protocol UPS Uninterruptible Power Supply USGS United State Geographical Survey VAC Volts Alternating Current VDC Volts Direct Current A-3

APPENDIX B INDEPENDENT TEST OF THE IPEC PROMPT ALERT NOTIFICATION SYSTEM Georgia

Tech M 400 W. 10th Street, N.W.

Atlanta, GA 30332-0844 Independent Test of the IPEC Prompt Alert Notification System Prepared by:

R. J. Gaeta, Ph.D.

Senior Research Engineer rick.gaetaggtri.gatech.edu 404-407-7805 Aerospace and Acoustics Technologies Division Aerospace, Transportation, and Advanced Systems Laboratory Georgia Tech Research Institute B-1

Independent testing of the Indian Point Energy Center's (IPEC) Prompt Alert Notification System Sirens were performed by the Georgia Tech Research Institute (GTRI) during the time frame of October 16 th, 2007 and December 19th, 2007. Tests were performed in an anechoic chamber and at an outdoor test site, both GTRI test facilities.

This document certifies that GTRI measured and reported sound pressure levels of these sirens using accepted and standard research techniques.

Anechoic Chamber Siren Acoustic Measurements Testing of both omni-directional and bi-directional siren systems (produced by Acoustic Technology, Inc.) were performed in GTRI's large anechoic facility. A special mount was designed and fabricated for testing in the anechoic chamber.

The sirens were mounted horizontally on a spit-like apparatus that was conducive to rotation and ease of testing alternate speaker horn pairs. Figure la shows as schematic of this siren mount Figure l b shows a photograph of the actual installation.

a. Siren mounting design for anechoic chamber testing.
b. Actual siren installed in anechoic chamber.

Figure 1 Siren mounting apparatus used for anechoic chamber testing at GTRI.

B-2

Instrumentation The sound pressure level transducers used during the test were 1/4-inch Bruel & Kjaer (B&K) 4939 condenser microphones.

These microphones use a A-inch to '1/2-inch adaptor to a B&K 2669 pre-amplifier (factory specification: <0.05 dB @ 500 Hz). The acoustic signals were conditioned with a B&K 2690 Nexus instrumentation amplifier (factory specification: +/- 0.02 dB accuracy) before being processed by a multi-channel Data Physics Abacus dynamic signal analyzer (factory specification: +/- 0.02 dB).

Calibration of microphones was performed each day of testing. The effect of all of the instrumentation is that the sound pressure levels are measured with an accuracy less than 0.1 dB and the measured frequency is within +/- 1 Hz.

Data Acquisition Acoustic sound pressure levels (SPLs) were acquired using condenser microphones. The electronic signals from the microphones were conditioned through a pre-amplifier, an instrumentation amplifier and filter, and a dynamic signal analyzer. These components are standard considered state-of-the-art for measuring acoustic pressures with the types of condenser microphones used in these experiments. A total of 12 microphones were used in the anechoic chamber. Nine microphones were arranged in a cross-array on 1 foot centers, see Figure 2.

The three remaining microphones were placed in reference locations near the siren, and at positions midway (but off axis) from the siren to the microphone array.

H MIb

  1. 1 MIG #2 MIb#6 MIc#7 MIc#3 Mbo#8 MIo#9

-- -- -0 _

0 MIG#4 0

MI0#

Figure 2 Microphone array as seen by the siren speakers in the anechoic chamber.

Figure 3 shows how this microphone array was positioned relative to the siren in the anechoic chamber. The center of the array (microphone #3) was 18.5 feet from the siren center axis.

B-3

microphone ArrayI IW

-U-A.

I Siren Mount Figure 3 Orientation of microphone array relative to siren mount in anechoic chamber.

Results of Anechoic Chamber Measurements Table 1 shows the average sound pressure levels (SPLs) recorded from the microphone array located approximately 18.5 feet from the siren axis.

Shown are the average Leq levels for 14 omni-directional sirens (four sirens taken from the field at IPEC and 10 new sirens delivered by ATI) and the bi-directional sirens for all runs sounded at 576 Hz and with all nominal systems working. The average Leq at microphone #3 (see figure 2) is shown. A summary of the individual tests that contributed to the values in Table 1 is contained in the first and third volume of GTRI's final report to Entergy [GTRI D5600_Volume 1 Final Report, GTRI D5600_Volume 3 Final Report].

Mic #3 Leq Omni Directional Sirens Average =>

129.7 dBC Predicted at 100 ft =>

115.0 dBC Bi-Directional Sirens Average =>

132.0 dBC Predicted at 100 ft =>

117.3 dBC Table 1 Average results for omni-directional and bi-directional sirens tested in GTRI's anechoic chamber. Levels measured at a nominal 18.5 ft sounding at 576 Hz.

B-4

Outdoor Siren Acoustic Measurements Acoustic Technology, Inc. (ATI) sirens were tested outdoors adhering to ANSI S12.14-1992 standard. The test site was located in Smyrna, GA on the properties of the Georgia Tech Research Institute (GTRI). The ATI omni-directional siren system consists of eight speaker homs. These speaker homs are mounted on top of a 50 foot pole with two homs pointing in orthogonal directions (each pair facing 900 apart). Figure 4 shows a photograph of this siren system mounted on a pole at the test site. Each speaker horn is driven by four acoustic drivers, each with an average power output of 100 Watts. Thus, the entire siren system has 3200 Watts of power.

A total of seven omni-directional sirens were 3tested outdoors. These were provided by Entergy, UInc.

The first four were taken off poles in the Figure 4 ATI omni-directional field and first tested in GTRI's anechoic chamber siren system mounted at the GTRI before being tested outside. The last three were outdoor test facility, new siren systems from the factory. In addition, amplifier boards, batteries and the field box used to store the electronics was also supplied to GTRI.

Site Description The selected site for outdoor testing was part of a GTRI radar testing range. The site consisted of a mostly flat, large field approximately 200 feet by 600 feet in extent. At one far comer was a radar tower. The opposite end of the field was bounded by a horseshoe of trees over 75 in height. At this location, a wooden pole was installed that rose 50 feet from the ground.

Atop this pole the sirens were affixed.

The radar tower was approximately 500 feet from the pole and the field was covered in grass. Figure 5 shows a photograph of the test site as seen from the top of the radar tower.

Measurement Position Measurements were made at several locations Outdoor Test Field along a line that was in the direction of a speaker Figure 5 GTRI outdoor test site.

horn pair. In addition to measurements at 100 ft in accordance with the ANSI standard, measurements were made at 18.5 feet, 200 feet, and for selected soundings 400 feet. Microphones were installed along the measurement axis on man lifts that positioned the microphones 50 feet above the ground. An array of five microphones was placed at 18.5 feet. A fixed microphone placed at the 100 foot location.

In addition (in accordance with the ANSI standard), a person held a microphone on a boom and rotated around the fixed microphone slowly in a two foot B-5

radius. At the base of the 100 foot location, a microphone was installed on a tripod about 5 feet off the ground. Fixed microphones were placed at the 200 foot and 400 foot locations. Figures 6 and 7 show the microphone set up at the GTRI outdoor facility.

Fu6a18.5 ft 1

a 2

ii 100 ft Siren 200 ft Figure 6 Measurement positions at 18.5 ft, 100 ft, and 200 ft.

Figure 7 Microphone measurement positions at the GTRI outdoor test site.

A schematic of the microphone measurement locations are shown in Figure 8. A utility box about 7 feet tall was located near 300 ft from the siren pole. This was not a big structure and didn't interfere with the ANSI standard 100 ft measurement location.

B-6

All distances both along the ground and vertically were accurate to within 6 inches. The microphones were sighted along the 50 foot measurement axis with a surveyor's transit.

For the last three sirens tested, microphones were placed only the 100 ft location.

400 ft 200 ft 100ft Measurement Axis at 50 feet elevation 5-mlc Array I stationary mic I rotating mic Utility Box Grass Figure 8 Schematic showing relative measurement locations at the GTRI outdoor test site.

Weather Conditions The weather conditions during the measurements were very mild. Wind speed and direction, temperature, pressure, and humidity were measured at the 100 ft (50 ft elevation) location as well as at the top of the siren location using a Young Model 81000 3-Axis Ultrasonic Anemometer weather station. Generally there was little or no cloud cover for these readings. Temperatures ranged from 49.2 F to 67.9 OF with the relative humidity ranging from 45% to 50%. The ambient pressure varied from 14.15 psia to 14.23 psia. No measurements were recorded with greater than 10 mph wind speed.

Ambient Noise Level Ambient noise at the GTRI test site fluctuated with automobile traffic and aircraft traffic from the adjacent Naval Air Station and Lockheed-Martin flight line operations. Testing was never initiated while planes were taking off or landing or taxing. Over the course of the outdoor testing the ambient noise levels were between 60 and 75 dBC. These levels are at least 30 dB lower than the sound of interest (the sirens) ensuring uncorrupted sound measurements.

Instrumentation The sound pressure level transducers used during the test were 1/4-inch Bruel & Kjaer (B&K) 4939 condenser microphones.

These microphones use a 1/4-inch to 1/22-inch adaptor to a B&K 2669 pre-amplifier (factory specification: <0.05 dB @ 500 Hz). The acoustic signals were conditioned with a B&K 2690 Nexus instrumentation amplifier (factory specification: +/- 0.02 dB accuracy) before being processed by a multi-channel Data Physics Abacus dynamic signal analyzer (factory specification: +/- 0.02 dB).

Calibration of microphones was performed each day of testing. The effect of all of the B-7

instrumentation is that the sound pressure levels are measured with accuracy less than 0.1 dB and the measured frequency is within +/- 1 Hz.

Test Results Table 2 summarizes the results of the Omni-directional and Bi-directional speakers tested outdoors for a sounding frequency of 576 Hz. Both the moving microphone average Leq and the stationary microphone Leq at 100 ft on axis are shown. A summary of the individual tests that contributed to the values in Table 2 is contained in the second and third volume of GTRI's final report to Entergy [GTRI D5600_Volume 2 Final Report and GTRI D5600_Volume 3 Final Report].

Moving Mic Leq

@100' [dBC]

Stationary Mic Leq

@100' [dBC]

Omni Directional Sirens Average =>

117.4 dBC 115.2 dBC Bi-Directional Sirens Average =>

118.7 dBC 116.7 dBC Table 2 Average Leq results for omni-directional and bi-directional sirens tested in GTRI's outdoor testing range. Levels measured at a nominal 100 ft sounding at 576 Hz. Measurements made using ANSI S12.14-1992 Standard Senior Research Engineer Aerospace, Transportation, and Advanced Systems Laboratory Georgia Tech Research Institute B-8

APPENDIX C AMBIENT NOISE SURVEY Blue Ridge Research and Consulting, LLC (BRRC) collected ambient sound levels at 13 locations within the IPEC EPZ. These locations were selected to coincide with locations where the sound level of a full system test was also collected. These locations were selected to generally be in high population density areas. The GPS coordinates and maps of the measurement locations can be found in BRRC's Final Report1. The thirteen locations are briefly described in the next table. Note that all of these locations were selected because they are generally in high density population areas with greater than 2,000 people per square mile.

Table C-1. Location and Description of the Ambient Measurement Locations.

Location Description County Cortlandt Off of Tate Ave. in Cortland NY Westchester Peekskill Off of Ringgold St. in Peekskill NY Westchester Croton-on-Hudson Off of High St. in Croton-on-Hudson NY Westchester Yorktown Off of London Rd. in Yorktown NY Westchester Mohegan Lake Off of Lawrence Rd. in Mohegan Lake NY Westchester Ossining Off of Fairview Pl. in Ossining NY Westchester Lake Peekskill Off of Point Dr. N. in Lake Peekskill NY Putnam Putnam Valley Off of Mountain View Rd. in Putnam Valley NY Putnam Highland Falls Off of Walker Ave. in Highland Falls NY Orange Fort Montgomery Off of Locust Ln. in Fort Montgomery NY Orange Haverstraw Off of Hoover Ave. in Haverstraw NY Rockland New City Off of Omni Ct. in New City NY Rockland Stony Point Off of Adams Dr. in Stony Point NY Rockland Type 1 Sound Level Meters (SLMs) were used to collect the ambient data. The SLMs used for this project were the Larson Davis 824S2 and 831s 3. Before each meter was put into service, its calibration was checked, and a calibration tone was recorded on each meter. After each test, another calibration tone was recorded on each of the meters to verify proper functioning.

The Model 831 SLMs were programmed to collect data every 1 second, while the Model 824s were only able to collect data every 6 seconds (due to memory limitations). Each SLM was programmed to collect third octave band data over the entire period they were in the field. The data was collected from August 16 through August 18, 2007.

1 "General Acoustical Analysis of the New Indian Point Siren System - Final Report',

August 2007, Blue Ridge Research and Consulting.

2 Larson Davis, 2004, "Model 824 Sound Level Meter Reference Manual" 3 Larson Davis, 2006, "Model 831 Sound Level Meter Operation Manual" C-1

Since weather plays an important role in noise propagation, and has an effect on the local ambient noise, weather data for the three days was also collected during the acoustic measurements.

There are many different ways to examine the ambient acoustical environment from data collected by a SLMs. The primary method utilizes the percent time exceeded metrics, such as the L50, which represents the sound level that is exceeded 50 percent of the time. For ambient sound levels the L50 represents a conservative representation of the currently occurring sound levels at a location. However, looking at the L90 helps to describe the quieter sound levels. The L90 represents the sound level that is exceeded 90% of the time and generally indicates the background levels of neighborhood without any noise intrusions. The L10, on the other hand, is the level that is only exceeded 10 percent of thetime and provides insight into the level of major noise intrusions occurring within a neighborhood.

Table C-2 shows the cumulative Li 0, L50, and the L90 percent time exceedances for all of the areas measured. The data is presented for the 2 8 th third octave band (TOB)

(centered at 630 Hz) which is third octave band where the majority of siren energy is.

The data was processed only for the hours from 7 AM to 10 PM.

Table C-2. The Cumulative Exceedances for the 2 8 th TOB (630 Hz).

Exceedance in dB Location L10 L50 L90 Cortlandt 43.0 38.0 33.0 Peekskill 40.0 35.0 28.0 Lake Peekskill 44.0 34.0 27.0 Putnam Valley 39.0 32.0 25.0 Croton 52.0 49.0 46.0 Yorktown 44.0 38.0 32.0 Mohegan Lake 35.0 28.0 24.0 Ossining 45.0 38.0 33.0 Fort Montgomery 36.2 30.2 28.2 Haverstraw 44.6 40.6 37.9 Highland Falls 41.4 37.2 32.9 New City 44.4 37.9 33.1 Stony Point 42.8 40.8 39.4 None of the L50 levels are higher than 49 dB. This means that any siren level that reaches the required 70 dB for high population density areas will be clearly audible above the ambient background noise.

Ambient Sound Variation with Time The background noise level changes with time. This change is due to random activity during any given day, and it is also-a function of the change in daily activity for both the people and the animals living in the area. Figure C-1 shows a sample of the hourly exceedances for Peekskill NY. This figure shows the hourly L10, L50, and the L90 for the three days that the meter was in the field. Here, both the daily cycle of the background noise as well as random intrusions into the background noise can be seen.

Note that the large increases shown in the L10 levels are not represented in the L50 nor C-2

the L90. This is because the L10 represents momentary intrusions into the background noise while the L50 and the L90 represent the more constant noise levels in the background. From this plot it appears that, for this location, the quietest hour is shortly after midnight, and the loudest part of the day is around noon daily.

I'z 50 45 a

o z

._1 40 35 30 25 I -I I

I I

I I

I L

.L...-.

L -----

L -.

.A.

a a

a I a a

4--------

a I

a a

I I

a a

a a

a a

. a

a.

i a

a a

a iaL a

a a:

a I

V, a..a.a.a aL10 a

i a

a a

a a

=

a..

.a.

a.a La a

a I

L90 i

i i

i i

i i

iL, 20 150 6

12 18 24 30 36 42 48 54 60 66 72 Hours Figure C-1. Time History of Hourly Exceedances for Peekskill, NY.

Conclusion BRRC conducted ambient noise measurements in thirteen locations within the EPZ for three consecutive days in August of 2007. The daytime (7 AM to 10 PM) noise data from these measurements was used to compute the local ambient noise environment.

The exceedance levels of L10, L50, and L90 were computed in the 2 8 th third octave band, centered on 630 Hz. The L90 levels, representative of the ambient background sound levels, ranged from 25 dB to 46 dB. The L50 levels, representative of the average sound conditions, ranged from 28 dB to 59 dB. The L10 levels, representative of the infrequent and transient noise intrusions, ranged from 35 dB to 52 dB.

C-3

APPENDIX D INITIAL TESTING Siren system testing was performed in two parts: factory acceptance testing and the instal lation/start-up site testing.

.GENERAL FACTORY ACCEPTANCE TEST PLAN A. Siren Test For each siren, the following steps were taken:

1) Visually inspect unit wiring, connectors, boards, and mounting hardware.
2) Verify battery charger operation and battery voltage level.
3) Verify battery heater is operational.
4) Verify address and configuration settings.
5) Verify local and remote status reporting.
6) Verify local and remote silent tests.
7) Verify Motorola signal capability: talk around communication, addresses, and Frequency Shift Keying (FSK) data communication.
8) Verify remote controller monitoring and site status conditions using radio and TCP/IP communications.
9) Verify activation commands.
10) Verify intrusion and loss of AC power reporting, driver alarms failures, door open alarm, and temperature alarm.

B. Control Station Test For each control station, the following steps were taken:

1) Visually inspect unit wiring, connectors, boards, and mounting hardware.
2) Verify that the workstation computer correctly operates with all installed software.
3) Verify the three levels of passwords.
4) Verify monitor and display maps.
5) Verify alarm monitoring.
6) Activate the system and verify correct display results.

D-1

7) Verify correct monitoring, displaying, and logging of unsolicited system messages from remote sites.
8) Perform and verify single, group, and total activations.
9) Verify automatic scheduled polling, activations, and siren silent test.
10) Verify archive and report printouts are performed for all system activities.
11) Verify that there is supervised communication between all communications control units. (NOTE: "Supervised communication" means that the communications is monitored.)

.12) Perform and verify all activation using only the front panel of the REACT-4000.

13) Verify that the control station UPS operates as specified by simulating the loss of AC input power.

INSTALLATION START-UP SITE TEST PLAN A. Control Station Verification

1) Visually verify proper equipment installation and wiring.
2) Verify proper software installation and operation.
3) Verify communication using both the REF link and the TCP/IP link separately.
4) Verify that the control station UPS holds the control station monitoring equipment loads under normal operation and under loss of AC input power.

B. Repeater Site Verification

1) Visually verify proper equipment installation and wiring.
2) Verify all repeater tower radio equipment is functional, including talk around

'communication and battery backup function.

C. Siren Pole Verification

1) Visually verify proper equipment installation and wiring.
2) Verify AC power is supplied and correctly wired.
3) Verify the batteries are installed and correctly wired.
4) Verify correct siren address and DIP switch settings.
5) Verify and check radio communication.
6) Verify and check TCP/IP communication D-2
7) Perform and verify both local and remote siren tests.
8) Perform a remote silent test and verify status reporting to the control station.
9) Verify status monitoring of the siren at the control station.

D. System Activation Verification

1) Perform a county-wide silent test activation for all sirens within each county and verify the results.
2) Perform both GROUP (for each of the four counties) and TOTAL silent test activations from the IPEC control stations and verify the results.
3) Repeat the above tests from each control station.

E. Backup Power Verification Post installation testing and inspections have been performed in accordance with approved procedures. This testing was conducted to demonstrate satisfactory performance of the siren system components as required by the NRC Order. Testing included:

Operation of the system with simulated degraded battery voltage was tested for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for four selected sirens, five control stations, and all four simulcast repeater towers. During this time, the system was maintained in the standby mode with periodic polling and monitoring of communication activity conducted. The test simulated the functioning of the batteries in an end-of-life and design temperature condition and included all tested components in a simulated degraded battery condition concurrently. At the end of the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, there was a simulated 15 minute siren sounding for the four selected sirens being tested after which the batteries at the tested locations were re-charged to at least 80% within a 24-hour period.

Verification that on a loss of AC power to the tested locations, indication of this loss was automatically provided to IPEC and notification messages to designated IPEC personnel were received.

Integrated siren activation/communication system reliability was tested as discussed in Section 10.

Additionally, other testing included:

Verifying the ability of alarm and control circuits at the simulcast repeater towers to report back to IPEC and initiate and complete an automatic transfer between the microwave and Telco channels for a fault condition.

Verifying the ability of the alarm and control circuits at the simulcast repeater towers to detect a loss of AC power to the simulcast system and perform necessary load shedding.

D-3

Verifying capability of each communication channel (radio microwave, radio telco, andTCP/IP cellular) to conduct polling both individually and collectively.

D-4

APPENDIX E LESSONS LEARNED In 2005, an evaluation of the former electro-mechanical IPEC alert and notification siren system was conducted to evaluate failure modes and causes. The following lessons were learned:

Points of Failure Within the former electro-mechanical siren system there were several single points of failure that had system-wide repercussions. The most significant of these was the primary communications device that transmitted activation signals to the sirens and received siren performance feedback data. The system used the IPEC meteorology tower, a 100-meter tall structure, to support the transmitter. If this transmitter was not available, it was not possible to activate sirens.

Each siren was itself also a potential point of failure. Because the siren consisted of a single rotating element, any failure that disabled that element prevented either siren rotation or siren sounding or both. Failure in this mode could have occurred as a result of a power outage or mechanical interference with the mechanical components.

The pair of host computers that sent activation signals was located at the IPEC Emergency Operations Facility (EOF). Even though these were redundant computers, their proximity made them susceptible to common failure modes.

Subgroups of sirens were activated via transmission of radio signals from repeaters located on selected sirens. A repeater failure could have constituted a single point of failure for a subgroup of sirens.

To avoid these failure modes, the new siren system has the following features:

Siren activation and monitoring is accomplished using simultaneous transmission over a variety of pathways. These include a radio system utilizing higher power radios with a 4-tower simulcast repeater system that is independent of the sirens (sirens are not used as store/forward repeaters to siren subgroups as in the former system) to broadcast activation signals and receive monitoring information. A wireless TCP/IP communications system broadcasts activation signals and receives monitoring information. The TCP/IP mode operates in parallel with the radio communications mode. This design eliminates single point communications failures.

The siren rotation sensor that could cause an electro-mechanical single point of failure was eliminated through the installation of fixed omni-directional and fixed bi-directional electronic sirens.

Each omni-directional siren pole has a total of eight siren horns mounted in two banks of four. Each of the siren horns has four independent speaker-drivers. A E-1

failure in a single driver leaves three remaining drivers within that siren horn.

Failure of a single driver associated with speaker horns in one direction does not reduce sound coverage in the EPZ below an acceptable level.

Host computers for the siren system are located at multiple locations. In each county, host computers are located at not less than two locations (warning point and emergency operations center). Those locations are physically separated and have separate backup power supplies. In this way, a failure of a single computer will not disable the system.

Communications Monitoring The former electro-mechanical siren system utilized frame relay telephone connectivity from activation sites to the host computer. The frame relay system was monitored at the host computer but failures were not automatically reported to responsible personnel until two modifications were made to the frame relay system in 2005 that caused responsible personnel to be notified of pathway failures.

The new siren system provides for automatic notification of responsible persons in the event of communications pathway failures. Sirens and control stations are polled on a regular basis; the polling is normally initiated from the GSB or EOF control stations and may be conducted over the two radio paths or over the TCP/IP paths. Failures are displayed on the control station and trigger a notification to responsible personnel. Upon loss of AC power at any control station, notification is made to selected IPEC personnel.

The display status changes for loss or inoperability of any county control station or for complete loss of any siren within that county.

Diagnostic Device Failures The former electro-mechanical siren system employed a series of diagnostic devices and computer logic relating the monitoring of these devices to determine whether or not the siren was in a ready state and, if activation was demanded, whether or not the siren performed its intended function. Several of these diagnostic devices had histories of failure as described below. These included the siren rotation sensor and sound detection acoustic sensor. The design of the new system eliminates these problematic diagnostic devices. In the new system, there are no rotation sensors because these are fixed sirens. The amplifier includes sensitive power monitoring circuits that monitor the state of the amplifier, speakers, and cables without external devices.

Failure History The former system utilized electro-mechanical sirens installed in the 1980's. A 10 or 15 HP AC motor was used to compress air between a stator and rotor to generate the siren discrete tones. The noise generated was projected to a larger distance by a horn. That same motor was used to rotate the horn to generate 3600 of sound coverage. The horn rotated at low speed (3-4 rpm) through the use of gears and a chain. To operate, the siren needed a 208-230 volt AC power feed and was activated by a radio signal.

E-2

In order to understand the failure modes of the former system, IPEC analyzed it over a three year period (2003, 2004, and 2005). The data provided were collected through several sensors such as an audio (acoustic) sensor, rotation sensor, etc. During the period reported, 1,560 activations were evaluated. The system reported 101 siren failures.

The failures during activations, as reported, were:

Rotation sensor 58 failures

" Audio sensor (siren noise) 22 failures Communications 8 failures AC power 12 failures Other 1 failure The operational experience of the former system indicated that rotation failures had a major impact on the system performance. If a siren failed to rotate, the horn projected sound in only one direction. This led to only 10% of the 3600 expected sound coverage for the failing siren.

Table E-1 provides a failure history as documented in IPEC Condition Reports. These reports document conditions adverse to quality during activations or discovered during preventive maintenance. In addition, Table E-1 identifies the features of the new system that address those failures.

E-3

Table E-1. Entergy Condition Reports (CR) from January 2004 to February 2006 CR Condition

-Dsign Feature of New System Gel cell batteries do not require water 1P2-05-00399 Add Battery Water for Electronic Siren.

addition and are low maintenance.

1P2-05-00316 IP2-05-00487 IP2-05-01467 IP2-05-03245 IP2-05-01099 IP2-05-05359 IP3-05-00075 Higher power for radios, simulcast IP2-05-02709 Communication Failure Control Station repeater system, and a second high IP2-05-04670 to Siren and Return.

speed communication path that is IP2-04-03786 redundant to the simulcast radio system.

IP2-04-04552 IP2-04-04899 IP2-04-06122

]tP2-04-01150 IP2-06-00596 IP2-06-00974 IP2-05-00417 IP2-05-04991 IP2-0400367 Icing affects rotation of siren.

Stationary sirens do not rotate.

IP2-04-00448

]tP2-05-01549 IP2-04-04471 IP2-04-04496 IP2-04-04498 IP2-04-04538 IP2-04-04539 Loose control system wires due to No rotation to cause vibration.

IP2-04-04502 vibration from motor activation.

IP2-04-04542 IP2-04-04545 IP2-04-04503 IP2-04-04547 IP2-04-04551 E-4

CR oCndition Design Feature of New, System IP2-05-02022 EP2-04-04351 IP2-04-04370 IP2-04-04369 IP2-04-04371 IP2-04-03938 IP2-04-02080 IP2-04-02799 IP2-04-02812 IP2-04-02814 IP2-04-02842 IP2-04-02676 IP2-04-02915 Faulty or jammed rotation sensor by No rotation and no rotation sensor.

IP2-04-03303 bird nesting.

IP2-04-02858 IP2-03-05400 IP2-04-06434 IP3-04-01124 IP3-04-03202 IP3-04-04108 IP2-05-00530 IP2-05-02709 IP2-05-03682 IP2-05-04170 IP2-05-04670 IP2-06-00646 IP2-05-04683 IP2-05-01294 IP2-04-00366 Motor and motor protection related No motor or motor protection or EP2-04-02675

failures, controls to fail due to stress of starting IP2-04-02841 under high voltage and current.

IP2-04-03608 IP2-04-04212 IP2-04-02860 IP2-04-02888 IP2-04-02946 IP2-04-03788 IP2-04-03918 IP2-04-03919 IP2-04-03920 IP2-04-03935 Sirens are DC powered from the battery IP2-04-03936 so they are designed to operate without IP2-04-04214 Power failures for driving siren motor to AC power for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in IP2-04-04435 generate sound.

"Standby" mode and 15 minute IP3-04-02771 activation. A motor is not required to EP2-06-00246 generate sound.

IP3-06-00152 IP2-04-01124 IP2-04-01124 IP3-04-02134 IP2-05-02209 IP2-05-03682 IP2-05-04170 E-5

CR Condition Design Feature of New System Speaker wire chewed by vermin Susceptible wires are protected from

'P2-04-00914 disabling siren partially.

damage by being installed in metal poles.

Notification of personnel turned off by Notification of personnel feature cannot IP2-05-04996 accident for period so no indication of system problems available.

No auto trending capability. Data must Design has auto monitoring. Ability to P2-05-04482 bmmore readily extract pertinent alarm IP2-06-00648 be manually compiled and thus not easy conditions for information recorded and IP2-06-00659 to see degrading conditions to take logdiremenaonfFiue IP-6069 action to repair/connect.

logged is recommendation of Failure Modes and Effects Analysis.

IP2-05-02345 IP2-05-03618 IP2-05-04001 IP2-05-04002 IP2-05-04248 IP2-05-04483 No frame relay connecting control IP2-05-03345 Failure of frame relay from County stations; radio and cellular IP2-05-03376 control station to host computer.

communication to communicate IP2-04-00438 between each control station and sirens.

IP2-04-00543 IP3-04-02434 IP3-04-04208 IP2-06-00149 IP2-06-00973 Backup power provided at all critical control locations in communication IP2-05-02987 Loss of power to primary radio for siren network. Multiple radios installed at IP2-05-02992 system.newr.Mlilraosntledt multiple locations, no single point of failure.

System includes a redundant communication system through radio

'P2-05-03748 Back up communication from County and TCP/IP protocol. Multiple control did not work.

communication control stations each containing radio and TCP/IP protocol at each county and IPEC.

Redundant communications systems

'P2-05-04484 Radio failure at repeater affects many provided. Sirens do not communicate sirens.

with each other only through repeater towers.

IP2-05-04713 Long distance and series repeater can Series repeater not used, radio power cause loss of control station signal.

increased and use of simulcast repeaters.

E-6

CR C onidition Dsg Feature of New ýSyse IP2-05-04598 Electronic siren speakers found faulty System has remote monitoring and periodic silent tests to verify problems IP2-05-05 116 by field examination at siren site.

with speaker/drivers.

IP2-04-04352 IP2-04-01124 The system does not use acoustic IP3-04-03202 Acoustic sensor failures result in false Tensyste oesino u se ou sensors. Failure of sirens is based on IP3-04-04108 negative siren activation report.

amperage measurements.

IP2-04000964 IP2-06-00516 IP2-05-04992 Radio failures at sirens.

TCP/IP and radio communications IP2-04000964 systems are redundant.

Software slowing down due to no auto Archiving is independent of other IP2-05-04395 clearing and archiving. Potential to affect activation and monitoring, system activities.

IP2-06-00780 IP2-06-00779 IP2-06-00768 Control system fabrication and IP2-06-00767 installation errors - wiring and antenna beenpformed to ad issues.

lIP206-0724 orintaton.been performed to address issues.

IP2-06-00724 orientation.

IP2-06-00515 IP2-06-00304 Table E-2 compares and contrasts the design features of the former and new systems.

Table E-2. Comparison of Former and New Systems No.IemFrerNew SystemI

Former, n Low power radio system and Simultaneous high power radio and I

Communication Lowen poweras reead tem a TCP/IP communication systems.

siren acts as repeater Sirens not used as repeaters 2

Siren Rotation Rotating electro-mechanical Non-rotating (fixed) solid-state siren electronic siren 3

Power Feed AC powered Battery operated or battery backup 4

Moving Parts Several moving parts No moving parts Extreme Weather Major parts can freeze in Heated battery compartment to ExConditions extreme cold weather withstand component extreme weather conditions 6

Siren Component Can cause total siren failure Failure of a single speaker-driver will Failure not cause total siren failure.

E-7

APPENDIX F SYSTEM EQUIPMENT DATA F-1

HPSS32 Omni-Directional Stationary Sound Pattern Model HPSS32 This omni-directional speaker assembly can be configured for operation of up to 3200 Watts of continuous audio output power; provides clear, reliable alarm tone notification and voice instructions for emergency warning and notification.

3200 Watts of Output Power (127 dBC at 100')

- Includes eight 400 Watt speaker assemblies with mounting bracket, 50 feet of speaker cable and a speaker pole mounting kit

  • One auxiliary Class D Amplifier with an interconnecting cable and mounting screws

. An additional ventilated and attached Stainless Steel battery compartment I I

Tone & Voice System

- NEMA4X Stainless Steel Enclosure Model HPSS This unit is configurable for operation of up to 3200 Watts of continuous audio output power. Provides clear, reliable alarm tone notification and voice instructions for emergency warning and notification.

  • Compliant with the UFC and FEMA requirements
  • 30 minutes of full, continuous operation
  • Seemless replacement for Electronic Mechanical Sirens STANDARD EUIPMENT.

Includes a NEMA4X Stainless Steel Siren control enclosure with an

.attached isolatedand ventilated battery compartment. enclosure mounting bracket and mounting hardware. The siren enclosure contains a Class D Amplifier integrated with a high performance controller section. a conven-tional VHF or UHF radio and mounting hardware, an intrusion switch, a temperature compensated battery charger and power ON/OFF circuit breakers

- Antenna equipment sold seperately per site requirements.

  • Produces eight standard alarm tones and live PA broadcast.
  • Custom alarm tones and digital messages.
  • Automatic Gain Control (AGC) for consistent output volume on live voice announcements.
  • Local and remote activation, testing and status reporting. One compact Class D Amplifier inte-grated with a high performance controller RTU, capable of producing 1600 watts RMS of con-tinuous output audio power.
  • Local and remote silent test

, A second (non-integrated) Class D Amplifier is required for 3200 watt operation.

  • Our Patent Pending Class D Amplifier is a robust and highly efficient amplifier design that maintains an efficiency of over 90% independ-ent of the input waveform shapes or amplitude.
  • ATIs Class D Amplifier uses a unique drive method that reduces stress, improves efficiency and reduces failures of the output audio drivers.
  • Very low amplifier popping during turn on and turn off further reduces premature and prevent-able sound driver failures.
  • All Printed Circuit Boards are conformal coated permitting the operation of ATIs siren in harsh environments.
  • Very high MTBF (Mean Time Between Failures)
  • New compact and robust siren system.
  • In the standard configured system, a radio is used to receive and transmit FSK data signals (Other Communication Media available.)
  • All Communication Transmissions use a revolv-ing security coding method to prevent unautho-rized system activations.

- Batteries are no' included.-

HPSS Enclosure Cabinets Battery Charger Assembly Main Amplifier Radio

& Controller Board 1600 Watt Auxiliary Amplifier Not to scale On/Off Circuit Breakers Batteries Additional Batteries Digital Message Board Main Amplifier

& Controller Board Radio On/OFF Sealed Battery Battery Charger Circuit Breakers Compartment Assembly and Batteries Model HPSS32 Enclosure Model HPSS16 Enclosure

,=

=

=

=

=

=

=

=

=

=

=

=

=

==............

1. Pre-Recorded Voice Message Option This option includes a pre-recorded Digital Message Board and storage PROMs. The pre-recorded messages are professionally recorded and then digitized and stored; available in blocks of 10, 50, or 100 individual messages If additional messages are required, consult factory (up to 254 messages are possible).
2. Solar Power Options Includes solar panels sized for your location, a regulator. 30 feet of power cable and solar pane! mounting bracket(s). Available in 55W.

75W. or 100W solar panels

3. Enclosure Upgrade The enclosure upgrade holds four batteries: this is required for both the HPSS16 and R-HPSS16 using solar power.
4. Trunked Radio Upgrade Replaces the standard, conventional radio with a 400, 800 or 900 MHz trunked radio to interface with your existing trunking radio system
5. Antenna Surge Protector Option Used in high lightning areas. Rated for 50.000 amps IEC
6. Strobe Output Option Controls a string of Strobe Lights of up to 10 amps of total current draw. Refer to the Strobe Selection Chart, to order the strobes separately.
7. Speaker Cable Upgrade Custom speaker cable lengths available in (10) foot incre-ments I,..,

ý t>;:v VMP.

01212/

r~ i'/iT o 5 t Ji f I.- m.

Operating Temperature:

-20'C to +85'C (-40'C with battery heater)

Standby without AC 8 days (2 batteries with 100 AHr capacity)

Maximu!p Alar Duration 3Q minutes.

Enclosure Weight (without batteries) 1600 Watt 90 Ibs (without batteries)

Enclosure size HPSS16 (in inches).

28" H x 22" W x 140 D I

e sp eakeSS32 (in 50 xb4 400 Watt Speaker Weight 50 lbs, AC Input Voltage

-l~

A r20 Maximum 0p eatin Current 3.5 A at 120 VAC or 2 A at 240, VAC Mode. Modjilation FSK.r...-rY d p [)T....

Radio Out ut Power 1 to 25 Watts Audio Output Power 1600 Watts. RM.S. Continuous per Amplifier.3200 WattsMaximum

' : 7~.$

L e:.

`..;

........ I,::

Power Bandwidth 250 Hz - 5 Hz Class of Operation True Class D Efficiency

> 90%

Oper n

O*nT perature

-40 to85.C

.t.

+.

Output Regulation 1 dB or better, no load to full load Operating Voltage Range 21 to;32 VDC Protection Protected against primary over current, output over current or shorts & out ut volta e s ikes.

Pror2r Stra JK~1~

0 "hboyis" pq reteqion' Addressing Dip switches. for. easy addres sselection..

Local: Activation Sixbpushbuttons. for local testing and :activation:

Radio Interface Universal radio interface and power connectors Expansion P.orts.

RS4B5i, RS232' a'nda se cnd 1.6Q -Watt amplfier.

Other Ports Interface port for up to two Digital Message Boards Other Features Build,:in AGC circuit. tone-generator, and digital adjustable audio gain.

Active Power without radio

< 100 milliamperes Standby P5ower mi!liamprS.

.*!n

-Recommended battery types Everstart #27DC-6 or Interstate #SRM-29 interstate #31-MHD or MK Batteries 8G31DT (Non-Sealed)

(Sealed)

~v~w~~etir-btteesco

,twww,,r,.ýerstatebattery~coni, w'v'iwomkba1,ze,- com

'9

Model CS The Control Station consists of a Communication Unit that interfaces to a computer station running ATI software. The ATI Software Package controls, operates, displays, and documents all system activities.

I 1_, '."4 J ;

" Performs Alarms, Live PA.,

Silent Test and Cancel operations.

" Easy to use operator interface requires minimal training.

" Activates the system and displays results.

, Operates all Indoor and Outdoor equipment.

" Monitors and displays unsolicited system messages from remote sites.

" Single (Individual), group (Zone) or (Total) activations.

" Configurable automatic scheduled polling, activations and silent test operations

" Configurations of various alarms

" Archive and report printouts are available for all system activities.

" Simple to use activation alarm software buttons.

" Three levels of configurable password protection.

" Supervised communications and redundant activation points with additional Communication Control Units.

I. ý'ounh Screen r,)ior !

coo Allows alphanumeric pagers to display emergency information when the system is activated.

Allows the computer to display weather information.

Includes a vertical rack mount cage.

shelves, and glass door which holds the REACT 4000 CCU, computer equipment and printer, Allows outdoor text message signs to Sfispcay emergency information w.vhen the T

s e

ctivated.

Displays your facility and the location of the indoor and outdoor emergency warning equipment.

0. Tr-nk Rdio Upgrade Replaces standard radio with a 800 or 900 MHz Trunked Radio to interface with an existing trunked system.

.3trobe O put iI Opt(**:o Controls a string of Strobe Lights of up to 2 amps of total current draw.

Refer to the Strobe Selection Chart to order the Strobes separately.

P f

r, *c o r ý.. t2 i,tt r Used in high ightning areas. Rated for 50.000 Amps !EC.

Model CCU The Communication Control Unit provides communications to control and monitor remote equipment.

  • Simple front panel controls allow the user to select the activation type and address (Total, Group or Single) using only a few steps
  • Cancel function to halt an alarm that is already in progress
  • Allows full functional testing of sirens without making noise (Silent Test)
  • LCD display guides the user through the necessary steps to activate and then reports system status information.
  • Handheld microphone to perform live public address. Desktop microphone optional
  • includes eight SPST relays and eight opto-coupler inputs to interface,ith external devices and four analog inputs
  • Uses ATI's advanced and secure FSK protocol and/or DTMF or -wo tones for old systems

. Configuration program allows the user to construct alarm sequences. Programmable for: alarm tone types. tone durations, pre-recordied message and number of cycles.

  • All FSK transmissions include a security method to prevent unauthdrized activations.
  • Interfaces to a conventional or trunkmng radio system, base station or leaosed ine circuit
  • Operates an internal mourted UHF or VHF conventional radio to communica te

ý,,,th the slren system, which can be

-j,)graded to Du:;dsrai;:0 0,

-.60 MHz. Other c

.. it -

e-may be used i'corsu "r

Includes a desktop cabinet, display screen. microprocessor controller, front panel push buttons, rear. entry connections, microphone, UHF or VHF conventional radio, N-Type RF connector and internal power supply.

8attery is not included. Requires one 12VDC, 7AH battery.

Battery idannufacturer and Part Number is: Yuasa NP7-12.

  • Antenna etu;pmerut sold separately. The radio output pover and antenna type are tailored for individual site recuirements.

H II P

DlllLI~I~

Fattst StIlL Tot' i

~GENERAL ASSEME a)

Wh.tempacet r the Rirndrition nd ling capabili permit it im s*trc.m (p*le and attachments) on the gWound and erec it as a unit-11%c be aliled on the ground and supported, typically with wood blocks, in su together. Care should he, taken to prevent dirt, stones, etc. from gelting,t b)

If the structtre (pole and aftachments) is assernbled vertically, cxtri am property arsenbled.

Th-POLEESIGN INFORMATION V

DSEAM IS THE MATCH MARK FOR T7)E ALIGNMENT OF "IHE TOP AND SnT.) SECTION se-tio., and attadhc*ns of the pole shouild_.

ich a inanner that they will readily lit SLPJITDSG EGH 3"

alppcd betwetmn the mating Surfaces.

caremay 1w necederto assure th'at all joint-, MIINIMUM SLIP JOINT LEGH.21 Proper 2lipment of the pole sections is laciltlalcd by the location of tle weld scaom.

it)

To facilitate the assembty, mating surtfoces may be lubricated. Care shod be ta not to u a lubricant tat wilt later leak frim the joint and stai the pole. SoVy water has been used sucoreefully for this purpose.

b)

The nominal splice lengilis for Valmont of El Dorado can he fomd im nthe pole assembly drawing, c)

A number of methods hae been considered for applying the necessary fome to achieve a tight joint. The methodseleacd may depend upon the size of the pole section,. th type of pole design, and the equipment availablce

'Thle two moat, 0anson m*thods are:

a Use of two (of more) ratchet chain hoists or similar devices on opposing sides of the poe sections, These may pull on cables secturd to the pole sections with a choker type hitch or attached to bolts installed in appropriate thorjh holeu.es, Equal Iros should be applied by the hoists simultaneously. If boltw ar used, forces must be applied no mnore tha I.2 inches ftom the surface of the pole section.

0 tIge ofa hydraulicjackng device which requires welded nuts attachied to the piolesctions (not a sandard);

d)

Whe*mthe forces we applied as a sow steady pull,joint tightening will be facilitated by oscillating the advancing seetion with the supp4rting crane or by strilkan Ove pole in the joint area with a hammer using a cushioning bka* of wood. These forces should be applied unil thejoint is tight with no mom than *mall gaps (which can sometimes be caused by a slight mismatch in the slapes of the mating sctions i TOP SECTION WIGHT -,

71 I *10 I PROPRIETARY 3IFORIMATI(O fl-E.

DOCUMENTS, DRAWINGS. AND)OR CALCULATrION AND ALL INFORMATION RELANT0 TO THEM ARE THE EXCLUSIVE PROPERTY AND THE PROPRIETARY INFORMATION OF VALMONT 04OUSTRIES.

INC. AND ARE FURNISHED SOLELY UPON TH CONDITIONS THAT THEy WILL BE RETAINEO IN TRrICTEST CONFIDENCE AND SHALL NOT BSE OUPUICATE.

USED OR DISCLOSED IN VWOLE OR IN PART FOR ANY PURPOSE, IN ANY WAY, WITtOUT THE PRIOR WRITTEN PERMISSION OF VALMON1 INDUSTRIES. INC.

e)

A final cheek should ht made Ii assure that the speci~red minlimun overlap has been achieved. An overlap betwta minimum and mnmrmum (nominal) splice is considered an acceptable joint provided the minimum force has been appied and no additional movement ofthejoint result fran an incivase hz.tPt!tjl force.

60T2 POLE 10 NEWMARK ENTERGY F~ir S10t57 06T2 V40fkK ORDo 101 4EV.

NO, QW.~i AGHQGOT2 APPROVEDO BY CUSTOIWR - SIGNJATUIRE fl)5Th1i11tORDATS OF API'RtC5AL SHO REV, NO.

SHOP REV. Y PAGE IOF 3_

MMUMQ~I~

7STUB SECTION NO DRILL

'UPPER & LOWER GALV HOLES WITHIN 2'- 6" FROM BOTTOM OF STUB; OPPOSING ANY UNDRILLED

PLANE, DRAWING NUMBER TO BE STAMPED ON ID FACE OF POLE SECTION AT TIP END. BY VALMONT.

4i-1V232" B4OLTHOLtýS2.5" F40M POE sBOl-TOM SHOP INSTRUCTIONS:

GALVANIZER INSTRUCTIONS:

1. BUT1T PLATE & POLE ID TAG INSTALLED BY GALVANWZER.

Z POLE 10 TO DE 13'-0r FROM BOTTOM OF STUB SECTON IN QUAD 8 8 INCLUDES: VALMONT. M0107 & 60T2 dlUrlLjLAN t'IV l I P13T 9-0" BAND OF POLYURETHANE TO EXTEND TO 9'-0 FROM BOTTOM OF STUB SECTION INCLUDING AE

!ARNG P*ATET0 E POLYURETHANE ON OTH SODES POLYURETHANE TO BE MIN. 20MLS ICK &74 FEATHERED AT TIP END.

ALL THREADED GALVANIZED ATTACHMENTS TO BE FREE FROM EXCESS GALVItNZATION, SO AS NOT TO IMPEDE FASTENER INSTALLATION.

ALI. STAINLESS STEEL THREADED ATTACHMENTS TO BE PLUGGED PRIOR TO GALVANVZATION.

TPOLES TO ENTERGY SJ IJ NTS iLo,2O007.

AGH00T2A WORK ORDER NO.

IMV. mo.

CUT. MY1. No.

AR CS~OY4EPSIGNATnRE.

RMIT" lAIT, 6M1 STUB tAPPf1OVCD-T6" Iero DATE OF Af"ROVAL SHOP REV.NO. ISHOP REV. BYF LS HPREfXV0AT I

10' PAGE 2OF 3

TOP se-'CON t

r

?rRom MIU. Tor SHOP INSTRUCTIONS:

UPPER & LOWER GALV HOLES WITh"N Z'- 6" FROM.

TOP OF POLE OPPOSING ANY UNDRILLED PLANE.

DRAWING NUMBER TO BE STAMPED ON ID FACE OF POLE SECTION AT TIP END, BY VALMONT.

  • _,PLASTIC TOP, CA.P _

I_9*

NO DRILL

-6.w 0 TOPcA F r-i GALVANIZER INSTRUCTIONS:

SH IePIN

1. TOP CAP & POLE ID TAG INSTALLED BY GALVANIZER.
2. POLE ID TO BE 3-" FROM BOTTOM OF TOP SECTION IN QUAD B INCLUDES: VALMONT, MOMT & 6WT2 RIVNUT~

1..~.-....----

ALL THREADED GALVANIZED ATTACHM,1ENTS TO BE FREE FROM EXCESS GALVINIZATION, SO AS NOT TO IMPEDE FASTENER INSTALLATION.

ALL STAINLESS STEEL THREADED ATTACHMENTS TO BE PLUGGED PRIOR TO GALVANIZATION.

SB C

A ENTERGY..--

DATC '"M 10W1. WO.

JG JNTS

'0152007.

AGHO0GT2B wL-R NO.

RF'.o.

ICUSl.REB.V0O L APmROVE-BY CUSTOEEER

- StGNATtmE AF%'PRtPOV S:

A~~~pRO AVAiC7.§ K:

-,---,-t----,-...

6M TOP 10 P

3

REPEATER COPONENT LIST Met Met Harriman Harriman Grassind Grassind Tinker Tinker Equipment ID Equipment Model No Rack Al Rack A2 Rack B1 Rack B2 Rack C1 Rack C2 Rack D1 Rack D2 Total "HARRIS" Intraplex Access Server ACS163TD 2

2 2

2 8

"HARRIS" Intraplex Cross Connect Server DCS9560 1

1 2

"Spectracom" GPS Ageless Master Oscillator 8195B OPT 02 14 2

2 2

2 8

"Spectracom" CTCSS Tone Generator 1118-0002-0600 2

2 2

2 8

"Raytheon" JPS Voter SNV-12 SNV-12 1

1 2

T1/E1 Copper to Fiber Media Converter (Met Bldg only)

SSDTF1013-105 3

"MDS" FIVE SERIES-050 MDS FIVE.8 1

1 1

3 6

"TPL Communication" Power Amplifier PA4-1 BE-RXRPSF-M 2

2 2

2 8

"Spectra Engineering" MX800 RF Transceiver MX800FFHNSZ2CD 2

2 2

2 8

"ATI" Repeater Monitoring Unit RMU-l 1

1 1

1 4

"Motorola Elgin" Antenna Duplexers 64544/SND 2

1 1

2 2

8 "Teleware" Band Pass Cavity Filter TWPC-2208-2 1

1 2

2 1

1 8

"Airlink" Raven Cell Data Modem CDMAC3211 1

1 1

1 4

"Bartly" Active Front End Crystal Filter UNI-Q 2

2 2

2 8

Audio/PTT CONVEX Distribution Panel 2241A 1

1 2

4YARRIS I

  • 1 A

g 4

iict Intraplex Access Server Reduce costs, simplify management, and maximize network availability by combining multiple applications including voice, data, audio, and video on a single digital link 0

next level solutions

@4 Ii'

!IARRs I~~.

)

'Sre 1E e

77WO Intraplex Access Servers provide a single, high-reliability multiplexing platform that enables a wide range of voice, data, audio, and video applications to share bandwidth on digital TI/El circuits.

SIMPLIFY YOUR NETWORK AND LOWER COSTS Today, many managers find that application growth threatens to increase network complexity, overhead requirements and recurring transmission costs beyond their existing resources. Intraplex Access Servers offer an alternative by delivering an integrated network access platform that allows multiple applications to efficiently share private or public network circuits. As a result, network managers can significantly reduce the need to add and manage additional, multivendor access equipment and circuits, while actually increasing perfor-mance and uptime.

Intraplex Access Servers feature a common architecture and platform that can seamlessly support almost any combination of T1, El or Nx64 transmission requirements over copper and fiber-based services, as well as licensed microwave, spread spectrum or satellite links in point-to-point or drop and insert configurations. Application modules are available for voice; LAN, synchronous or asynchronous data; audio and video. Product design allows application modules, network interface modules, and power supplies to be shared and swapped between units for additional flexibility and savings.

The Access Server is available in a 3 rack-unit package providing maximum application flexibility or a space saving 1 rack-unit enclosure.

UNMATCHED PERFORMANCE Intraplex Access Servers outperform other multiplexing products by incorporating unique transmission tech-niques that deliver enhanced robustness and maximize end-to-end circuit availability for real-time application traffic and services. As a result, these products can maintain connectivity, even under network conditions and error rates that would cause other equipment to fail.

The product can be configured to provide power supply and common equipment hardware redundancy, with automatic switchover when any failure is detected. Complete automatic line protection switching options are also available.

The TI Access Server includes an integrated Channel Service Unit (CSU) that provides performance monitoring and electrical protection, allowing for direct connection to public networks.

REDUCE THE NETWORK MANAGEMENT BURDEN Integrating transmission requirements on the Intraplex Access Server eliminates the need to configure, maintain, and manage a proliferation of specialized equipment. The product's Windows-based graphical user interface and command line interface simplifies local or remote configuration, system diagnostics and monitoring of performance and alarm information.

Bandwidth can be allocated to the Server's built-in network management communications channel for remote monitoring, and a single Access Server can be used as a gateway to collect, store, and forward network management information from other Access Servers located in one network.

INTRAPLEX ACCESS PRODUCTS A(

RANGE OF PLUG-IN VOICE, DATA, VIDEO MODULES WHICH ALLOW t CUSTOMIZED COMBINATIONS OF I CHANNELS TO MEET SPECIFIC APF REQUIREMENTS.

A SINGLE ACCESS SERVER CAN ACT AS A NETWORK MANAGE-MENT GATEWAY ALLOWING REMOTE CONTROL AND MONITORING OF OTHER ACCESS SERVERS IN THE SAME NETWORK.

INTRAPLEX CHANNEL MODULES In addition to standard voice and data modules, the Intraplex Access Server also supports specialized channel cards for variable-rate transmission at non-standard data rates, variable bit rate/resolution video, audio encoding and user-programmable delay for synchronizing payloads from multiple network destinations. For a complete list of modules, please see the Intraplex Network Access Product Summary.

MEETING APPLICATION AND INDUSTRY REQUIREMENTS

" Mobile Radio-For transmission of two-way radio traffic, including Motorola SECURENETTM, between dispatch centers and transmitter sites

" PCS/Cellular-For interconnection of cell sites, base transceiver stations, and mobile switching centers, including remote control and order wire applications

" Satellite Applications-Applications include variable data satellite networks supporting point-to-point and point-to-multipoint networks, both full-duplex and one-way

" LAN Connectivity-For LAN extension and bridging, including distance learning networks

" Specialized Audio-For transmission of linear uncom-pressed as well as compressed high-quality audio in a variety of formats including MPEG Layer 2 and 3, apt-X100 and J.41 Intraplex Access Servers are in daily use, helping to Intraplex Transmission Solutions offers customer meet industry and application needs in a variety of assistance with network design, planning.

settings, including:

application support, and training.

SITE 3 TI/EM T

TI/E1

//0

EPT A WIDE WUDIO, AND
ERS TO CREATE

.14 SITE 2

I In

-rpe Aces Seve TE Sei icain INTRAPLEX ACCESS SERVERS:

Access Server ACS-160 Series 3RU 1RU TI Terminal multiplexer ACS-163 ACS-167 Ti Drop & Insert multiplexer ACS-1 65 ACS-1 68 Ti Dual Terminal multiplexer ACS-1 66 ACS-1 69 Access Server ACS-260 Series 3RU 1RU El Terminal multiplexer ACS-263 ACS-267 El Drop & Insert multiplexer ACS-265 ACS-268 El Dual Terminal multiplexer ACS-266 ACS-269 T1 INPUTS/OUTPUTS Connector RJ-48C, 100 ohms or DB-1 5, 100 ohms Frame Formats Extended Superframe (ESF)

D4/Superframe (SF)

Per ANSI T1.403-1995 and AT&T Pubs 62411 Line Codes Bipolar with 8 Zero Substitution (B8ZS)

Alternate Mark Inversion (AMI)

Timing Internal, 1.544 Mbps +/-30 ppm output External, RS-422 clock input Loop Line Build Out (LBO)

Up to 655 feet from standard DSX or CSU LBO 0, -7.5 or -15 dB Integral CSU Does not require external CSU for connection to public network FCC Part 68 Registered El INPUT/OUTPUTS Connector BNC, 75 ohms or DB-1 5, 120 ohms or RJ-48C, 120 ohms Frame Formats Channel Associated Signaling (CAS)

Common Channel Signaling (CCS)

Per ITU G.703, G.704 and G.706 Line Codes High Density Bipolar 3 (HDB3)

Alternate Mark Inversion (AMI)

Timing Internal, 2.048 Mbps +/-30 ppm External, RS-422 clock input Loop STATUS & DIAGNOSTICS LED Indicators Shelf Power, Normal, Alert, Alarm Contact Closures Alert, Alarm Loopbacks Line loopback, Equipment loopback, Payload loopback Test Access Bantam jacks for TI /El input/output signal and Ti /El input/output monitoring CSU Performance Monitoring (TI)

Compliant with ANSI T1.403-1995 Compliant with AT&T Pub 54016 (standard and enhanced parameters)

REMOTE ACCESS & CONTROL User Interface Remote programming and monitoring using ISiCL command-line interface or IntraGuideTM graphical user interface software Control Interface RS-232C and RS-485 asynchronous for user interface ANSI T1.403 Performance Report Messages on TI Facility Data Link AT&T Pub 54016 Polled Performance Reports on TI Facility Data Link Network Management Communications Remote control and monitoring of Access Server(s) over the network using fractional DSO timeslot PHYSICAL & ENVIRONMENTAL Power Requirements 3 RU: Universal AC standard Optional -48VDC, -24VDC or +24VDC Optional hot-standby redundant supply 1 RU: Universal AC Nominal Power Consumption 3RU: Fully loaded system less than 40 watts typical 1 RU:

Fully loaded system less than 13 watts typical Temperature 0°-50°C Operating Humidity 1 0/-90% Non-condensing Dimensions 3 RU: 5.25" (13.4 cm) H x 14.75" (36.8 cm) D x 19" (48.3 cm) W rack-mount 1 RU: 1.75" (4.5 cm) H x 14.75" (36.8 cm) D x 19" (48.3 cm) W rack-mount Regulatory Compliance CE Compliant FCC Part 15, Part 68 UL 1950 CS-03 CTR1 2, CTR1 3 next level solutions Network Access Products I Intraplex Transmission Solutions 59 Porter Road, Littleton, MA 01460 USA 1-978-486-9000 I Fax: 1-978-486-0660 I e-mail: sales@intraplex.com I www.harris.com Copyright 02000 Harris Corporation 04/00 SEC-504790

ADV 3224 7/8/05 11:42 AM Page 1

ýPARRs" assuredcommunications-'

Intraplex T M SynchroCast System Newrkn Soluions SynchroCast System

> Make better use of available frequencies

> Improve coverage area including in-building use

> Fill in shadowed areas with booster transmitters Proven Harris Intraplex Technology SynchroCast is based on the Intraplex Access Server, a proven multiplexing product for the mobile radio and critical communications markets. It uses GPS technology to establish radio frequency and networking delay references.

Intraplex SynchroCast Allows you to use a limited number of radio frequencies to cover a wide area of coverage. Turning a portion of your mobile radio network into a simulcast radio improves penetration in areas with marginal coverage. Adding simulcast can also allow you to increase the channel capacity of your radio system without adding additional frequencies to your network. Smaller radio systems can now gain the advantages of proven Intraplex SynchroCast technology without the need to install a completely new radio system.

ADV 3224 7/8/05 11:42 AM Page 2 Using Precise Timing from GPS Satellites Now, for the first time, mobile radio system operators can install a simulcast radio system on a single channel or an entire mobile radio system without having to install a completely new system.

The SynchroCast system makes new GPS-based technology available to older mobile radio networks.

It gives users easy control of system functions that are critical to adjusting the coverage area to achieve desired performance. The Harris product also provides reference signals to the base station for precise control of channel frequencies. The system uses either T1 or E1 transmission lines now readily available from Telco carriers or via private networks. These can be traditional land based, microwave or fiber optic links, In fact, these systems can include a combination of public and private network links and still precisely control the necessary parameters to achieve peak simulcast performance.

Adding fill-in transmitters for shadowed areas.

A location that is shadowed because of a geographical feature can now use simulcast to add the necessary coverage without having to apply for an additional frequency.

SynchroCast automatically adjusts for network links delays The SynchroCast system works with most Harris Intraplex channels modules. For conventional radio systems, model numbers VF-25 (4 Wire) or VF-28 (4 Wire Tx only) can be used for the voice channels of the system. The standard voice channels may also be used for simulcast paging systems. Data channels operating at 9.6 kbps are available for newer digital voice mobile radio systems. The SynchroCast system will automatically adjust for any link delays that occur from network rerouting. The delay is sampled once per second. If a change in delay persists for two seconds SynchroCast will initiate a delay correction. Once the delay correction is started the shift in delay time is done seamlessly without interruption to the system operation.

Why use SynchroCast?

Make better use of available frequencies With a limited set of frequencies available for mobile radio applications, getting to most from the ones you own is essential. By simulcasting the current frequencies, the operator can increase the coverage and typically the channels of the radio system.

SynchroCast System Requirements SynchroCast is ordered as an add-on package to the Intraplex Access Server system. The SynchroCast Package includes the timing modules, data transmission modules, and digital delay modules necessary for synchronizing the control site and two base station sites.

Increase coverage and channels without adding frequencies.

A simple radio system may use 3 frequencies distributed over an area to provide coverage.

Converting this to a simulcast system allows the user to cover the same area with one frequency.

This will release the two additional frequencies for reuse as more channels on the radio system or for use by another agency.

SynchroCast Expansion The expansion package includes the timing module, data transmission modules, and digital delay module for each additional basestation site beyond the first two.

GPS Receiver One GPS receiver is required for each base station site in the system and the control point site.

Improve in-building coverage Simulcast often improves coverage inside of buildings.

This is driven by the RF penetrating the exterior from different sides and thus increasing the likelihood of having radio access inside the building.

Consult Harris Networking and Government solutions for recommended models.

Li Specifications are subject to change. For a complete listing of the most current specifications, please visit our Website at www.harris.com.

assuredcommunications" Harris Corporation 1 4393 Digital Way I Mason, OH USA 45040:

phone: +1 888-796-9827 I email: intraplex@harris.com I www.harris.com/publicsafety Trademarks and tradenames are the property of their respective companies.1 Copyright © 2005 Harris Corporationl 4

Printed in USA on Recyclablel:Paper HMC 16591 PP ADV. 3224A 07/051

Intraplex CrossConnect Specifications fjftRRI assuredcommunicatfons" Intraplex CrossConnect Systems

& Servers:

DCS-9500 6 Port TI CrossConnecs System, 1 RU package, protection switching and multicasting capability DCS-9530 6 Port TI CrossConnect System, 3 RU package, protection switching and multicasting capability with future migration to DCS-9560 DCS-9560 6 Port TI CrossConnect Sewer, 3 RU package, up to 24 DSO terminations (capacity of one Tt line), includes the functions of the DCS-9500, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications DCS-9565 6 Port TI CrossConnect Sewer, 3 RU package, up to 48 DSh terminations, indudes the functions of the DCS-9500, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications DCS-9500E 6 Porr E CrossConnect System, 1 RU package, protection switching and multicastingcapability DCS-9530E 6 Port El CrossConnect System, I RU package, protection switching and multicasting capability with future migration to DCS-9560E DCS-9560E 6 Port Er CrossConnect Sewer, 3 RU package, up to 31 DS0 terminations (capacity of one Ei line), includes the functions of the DCS-9500E, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications DCS-9565E 6 Port El CrossConnect Sewer, 3 RU package, up to 62 DS0 terminations, includes the functions of the DCS-9500E, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications TI Inputs/Outputs Electrical Interface Six DSX-I interface ports per ANSI Ti. 102 Output Timing Internal. 1.544 Mbps +/- 30PPM External, RS-422 input Any of the 6 TI inputs Frame Formats Extended Superframe (ESF)

D4/Superframe (SF)

Line Codes Bipolar with 8 Zero Substitution (68ZS)

Alternate Mark Inversion (AMI)

Line Build Out (LBO)

Up to 655 feet from standard DSX or CSU LBO 0, -7.5. or -15 dB Input Connector 8-pin RJ-48C for CSU applications DB-i 5 for non-CSU applications 100 Q resistive (nominal)

El Inputs/Outputs Electrical Interface Six Et interface ports per ITU-T G.703, G.704, G.706 Output Timing Internal, 2.048 Mbps +/- 30 PPM External, RS-422 input Any of the 6 EI inputs Frame Formats Channel Associated Signaling (CAS)

Common Channel Signaling (CCS)

Line Codes High-Density Bipolar 3 (HD83)

Alternate Mark Inversion (AMI)

Connector 75 ohm BNC (standard) 120 ohm DB-15 (optional)

Throughput Delay One to three TI/Er frames 125 to 375pS Two frames average 250pS DSO Interfaces (CrossConnect Server)

Optional 4W VF, 2W VF, sync, async and variable rate data, program audio, video Time Slot Mapping Maps Supported Eight: Two normal service maps and six alternate service maps configurable to switch based on T1 or Ei port failure (BER, LOS, AIS, LOF), external contact closure inputs or ASCII command.

Switch Time Protection switching delay programmable down to I ms Status & Diagnosis LED Indicators Shelf Power, Normal, Alert, Alarm DCS Port Status, Alert, Alarm Contact Closures Shelf Alert, Alarm DCS Alert, Alarm, Active Map Indicators Diagnostics TI, Er and timeslot loopback Remote Access & Control Functionality Remote programming and monitoring, PC-based Graphical User Interface and command line interfaces. Off-line copying and editing of cross-connect maps Interface RS-232C & RS-485 asynchronous PHYSICAL & ENVIRONMENTAL Power Requirements 3RU:

Universal AC standard Optional 48VDC or 24VDC Optional hot-standby redundant supply 1RU:

Universal AC Nominal Power Consumption DCS-9500/9530: 5 watts DCS-9560: 8 watts DCS-9565: 11 watts Temperature 0' - 50'C operating Humidity 0% to 90% non-condensing Dimensions 3 RU - 5.25" x 14.5" x 19" rack-mount 1 RU - 1.75" x 14.5" x 19" rack-mount Regulatory Compliance CE Approved UL 1950 FCC Part 15, FCC Part 68 CS-03 i

Networking Solutions Intraplex CrossConnect System and CrossConnect Server Increase the efficiency of digital transmission networks, reduce recurring costs and protect critical T1/EI network traffic SpKfaosare trilSct to chrugle.

/bra5 complete li010n n/ the muast crwnejian assuredcommunicatfions Harris Corporation I 4393 Digital Way I Mason, OH USA 45040 phone: +1 888-796-9827 I email: intraplex@harris.com I www.harris.com/publicsafety Trademarks and tradenares are the ropenrty of thew rnespetive uohopanies.

Copyrig91 2005 Harris Corooratim LePurnted in USA on Reyclable Paper HMC 16r591 PP AV. 3222 tCUts

Intraplex CrossConnect Systems and Servers allow network operators to reduce recurring transmission costs, while enhancing their ability to manage and protect critical T11EI network traffic across multiple digital facilities.

TJ4RRI INTRAPLEX CROSSCONNECT SYSTEMS INCREASE OVERALL TRANSMISSION EFFICIENCY T1 and El digital transmission services allow users to combine voice, data, LAN, video, program audio and other specialized communications services on a single circuit.

This can result in significant cost savings over use of individual, un-bundled services, while providing the high quality transmission capabilities available only through digital facilities.

When communications requirements or geography demand connectivity among several different sites, the network fabric may grow to include multiple, meshed Tt or El lines. Intraplex CrossConnect Systems and Servers can help manage these lines to ensure the most efficient use of the available transmission capacity and reduce costs. For example, circuits carrying phone traffic during the day can be reconfigured to carry batch data traffic at night, while existing, underutilized timeslots can be redeployed to accommodate network growth.

Intraplex CrossConnect Systems and Servers give users complete flexibility to combine, interconnect and multicast traffic among up to six Tt or Et lines. In addition, the CrossConnect Server accepts a wide variety of plug-in modules for integrated drop and insert of voice, data, program audio, and video services.

Users can program and monitor both systems remotely, using the IntraGuideTM Windows-based user interface. Visual times/ot mapping features allow users to easily program CrossConnect links.

CrossConnect maps can be copied for off-line editing and then uploaded to the unit.

CROSSCONNECT HIGHLIGHTS:

Reduce transmission costs in PCS, cellular and mobile radio networks

" Groom, concentrate and hub up to six T1 or El circuits from remote cell sites or base stations

" Upgrade, reconfigure and manage your network facilities remotely

" Integrate CDPD, mobile data, enhanced services and control channels with voice backhaul traffic, without adding capacity

" Manage analog-to-digital migration or co-location Consolidate traffic in enterprise networks

" Combine PBX, Internet, LAN and video conferencing traffic from multiple loca-tions into common T1 or El circuits

" Provide a single point of connectivity for integrated access to voice, video and data services INTRAPLEX CROSSCONNECT SYSTEMS PROTECT VALUABLE Ti/E1 NETWORK TRAFFIC Automatic protection switching and backup capabilities are essential for maintaining network performance and ensuring continuous service for all links on your digital network. Intraplex CrossConnect Systems and Servers can instantaneously detect any degradation or failure of a controlled TS/E1 line, seamlessly switching traffic to predesignated backup facilities, eliminating costly down-time.

Telephone company circuits or microwave radio links can be used for back-up. Both point-to-point and ring protection configurations are supported.

Maximize radio broadcast resources SMix and match program audio, voice and data feeds among multiple studio and transmitter locations

" Save on programming, talent and administrative costs by sharing transmission resources among stations

" Provide automatic backup protection and switching for studio-to-transmitter (STLI links

> Multicast encoded audio or video feeds from a studio to multiple receive sites Harris Public Safety I

Toll-free: 1-888-796-9827 h

www.h arris.com/pu blicsaf ety

iW ElIi S P E C T S.

SnhnzngCiia

.~erto Ageless GPS Master Oscillator Model 81 95B

  • Simulcast Transmitter Frequency Control

+/-0.01 Hz at 800 MHz

  • Precision Frequency Offsets Improve Simulcast Reception

" Zero Calibration Costs

" Reduce HDTV Adjacent Channel Interference

  • Ti /E1, SONET, and ATM Synchronization
  • Calibration Labs, Engineering Labs and Factory Reference
  • GPS rime RAIM Satellite Error Detection

" 5-Year Limited Warranty The patented Spectracom Ageless Master Oscillators are highly accurate frequency and timing sources. This model uses an Oven Controlled Crystal Oscillator internal reference. See Model 8197B for the Rubidium reference.

Outputs are locked to the U.S. Naval Observatory via the NAVSTAR Global Positioning System (GPS). T-RAIM (Time Receiver Autonomous Integrity Monitor) algorithm detects and disqualifies faulty satellites to maintain the reliability of system outputs.

Spectracom's field-proven Ageless Oscillator technology provides continual automatic frequency control, compensating for aging and temperature drift.

They are ideally suited as a site master oscillator for communication sys-tems. Typical applications include calibration, land mobile simulcast, nar-row band land mobile radio, SMR (Specialized Mobile Radio), paging simulcast, satellite/microwave communication links, T1/E1, cellular tele-phone, SONET and ATM enterprise timing and broadcast radio and televi-sion.

In simulcast systems, the precision frequency offset feature minimizes carrier phase cancellation in overlap areas. The CTCSS generator outputs are aligned site to site.

If AC power fails, an optional battery maintains the oscillator at its opera-tional temperature thereby reducing the recovery period by eliminating oscillator warm-up and retrace. In addition, the battery keeps the electronics in standby mode to allow rapid recovery of the GPS 1 PPS, Data Clock, and Data Sync outputs once power is restored.

Spectracom offers other system components, including distribution ampli-fiers, frequency synthesizers, clock selectors and clock converters.

www.spectracomcorp.com sales@spectracomcorp.com 95 Methodist Hill Drive. Rochester, NY 14623 USA Phone: +1.585.321.5800

  • Fax: +1.585.321.5218

95B 5O~

P~ Eu C' Aý0M OUTPUT ACCURACY:

locked:

+/-1 X 10-typical, 24-hour average unlocked:

+/-2 x 10 9 /week typical aging FRONT PANEL 10 MHz:

One 10 MHz output (BNC Female); 750 mVrms sinewave, 50 ohm impedence 30 dB harmonic suppression.

1 PPS:

1-L signal (BNC Female), accuracy is +/-500 nanosecond typical with SA off and in position hold.

DATA COMM PORT:

RS-232 (DB 9 Female) interface for maintenance and performance monitoring.

REAR PANEL 10 MHz:

Four 10 MHz outputs (BNC Female); 750 mVrms sinewave, 50 ohm impedance 30 dB harmonic suppression.

PHASE NOISE AT 10 MHZ OUTPUTS:

Phase Noise:

Offset.

<97 dBc 1 Hz

<110 dBc 10 Hz

<125 dBc 100 Hz

<135 dBc 1000 Hz Programmable Precision Frequency Offsets:

Zero offset plus 4 positive and negative steps. Step sizes in Hz: +/-3, 5, 7, 9 at VHF Hi and 0.5, 1, 1.5, 2 at UHF TIMING OUTPUTS:

1544 kHz (Ti rate) and 2048 kHz (El rate) @ RS-485 levels )RJ-1 1)

ATA CLOCK OUTPUTS:

9.6 kHz, 18 kHz, and disciplined 1PPS at RS-485 levels (DB 9 Female)

DATA SYNC OUTPUTS:

64 kHz, 18 kHz, 17-2/3 Hz, 33-1/3 Hz at RS-485 levels (DB 15 Female)

ALARM OUTPUTS:

Relay contacts SPDT, 2A @ 30 VDC (terminal strip)

DATA COMM PORT:

RS-485 (RJ-1 1) interface for maintenance and performance monitoring.

GPS ANTENNA:

L1, C/A Code transmitted at 1575.42 MHz ("N" Type Female)

Received Frequency: 1575.42 MHz Satellites Tracked: Up to 12, simultaneous, GPS T-RAIM satellite error management POWER:

115/230 VAC +/- 15%, 50/60 Hz. (3-prong connector, 7' cord included)

Maximum power consumption, 60W. Option 03 adds 30W.

OPTIONS Battery:

Option 02 Internal Battery, available only with 81958 with 115/230 VAC power. After power failure of up to 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> with 81958 reduces oscillator lock time to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, from 3-4 hours, and enables rapid recovery of GPS 1 PPS, Data Clock, and Data Sync outputs. Option 02, Internal Battery, not available with SP294 or SP295.

Built-In Distribution Amplifier:

Option 03 converts (4) 10 MHz rear panel outputs to the equivalent of Model 8140. Provides 10 MHz and + 12 VDC to power LineTaps, MultiTaps, and VersaTaps which can also provide frequencies other than 10 MHz. For more infor-mation, see Model 8140 data sheet.

Frequency Outputs:

(4) 10 MHz rear panel outputs are converted to 12.8 MHz (Option 6), or 5 MHz (Option 0/1 CSS Outputs Option 14 provides two low-frequency RS-485 outputs, to nearest 1/3 Hz, syn-chronized to GPS on-time point. Uses Data Sync Output connector. Option 17 5ý¢dfictiw, AjW lo change o, ampro- -l ilh..1 -ol6o-Sp -~a, N6l1k.k, Ti-Vi-1, Time'ad, T..eTa p, Mr*

L~g.1, Traeble T...ar

,oi*erd trde-6ks od Spotoaoom Cor,,ortio., All gib peduc., ae idetified by I.de*,k oF 1h1,,,-1,o v coponi. 0 orgnzfo, e 2006 Sp m*o Cýovoion, Printd i. USA.

0806-8195B(H) provides 2 additional integer frequencies on DB9 Data Clock Connector. One Model 1118-2: CTCSS Filter Board is required per base station to be synchro-nized.

Power:

12 VDC; Option 52, +/-13.8 VDC +/-20% (terminal strip) 24 VDC; Option 53, +/-27.6 VDC +/-20% (terminal strip) 48 VDC; Option 54, +/-55.2 VDC +/-20% (terminal strip)

TI/El Outputs:

SP294: Adds (2) Ti (DSI Framed All 1's) outputs (terminal block)

SP295: Adds (2) E 1 (All 1's - CAS multiframe) outputs (terminal block)

Option 02, Internal Battery, not available with SP294 or SP295 1 PPS Outputs:

1 PPS TTL outputs in place of frequency outputs 3 and 4.

Mounting Slides:

Option 11 provides mounting slides to enable rack mounting in a 19-inch rack with slide-out capabilities.

PHYSICAL & ENVIRONMENTAL SIZE/WEIGHT:

EIA 19"w X 3.5" h (2ru) x 12.5" D/20 lbs. maximum INDICATORS:

Power, tracking GPS, oscillator locked, battery ready, battery charging, battery fault, minor alarm, major alarm ENVIRONMENTAL:

-30°C to +60*C )-22*F to +I 40°F) operating range 95% R.H. non-condensing FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits ore designed to provide reasonable protec-tion against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ORDERING INFORMATION

1. Specify Spectracom Model 81958, plus:

Option 02: Battery Backup (on 81958 AC version only)

Option 03: Internal Frequency Distribution Amplifier Option 06: 12.8 MHz outputs Option 07: 5 MHz outputs Option 11: Mounting Slides Option 14: CTCSS outputs 1 and 2 Option 16: 1 PPS TTL outputs in place of frequency outputs 3 and 4 Option 17: CTCSS outputs 3 and 4 (integers)

Option SP294: TI Option SP295: E l For power input other than 115/230 VAC:

Option 52:12 VDC Option 53: 24 VDC Option 54: 48 VDC

2. Specify Antenna and Accessories:

GPS outdoor antenna, Model 8225 and mounting hardware Antenna Preamplifier, Model 8227 Antenna Surge Protector, GPS, Model 8226 Antenna Flat Roof Mount, Model 8213 Antenna Cable, LMR-400 equivalent, CAL7xxx, xxx=length in feet

3. Specify Model 1118-2: CTCSS Filter Board (one per Base Station)

Example: Model 81958-02, Model 8225, Model 8226, CAL7100 WARRANTY:

5-Year Limited Warranty I

www.spectracomcorp.com

  • sales@spectracomcorp.com 95 Methodist Hill Drive
  • Rochester, NY 14623 USA Phone: +1.585.321.5800
  • Fax: + 1.585.321.5218 ~h1

CTCSS Tone Generator Specifications The Model 1118 CTCSS Tone Generator is used in conjunction with the Model 8195A or 8197 Ageless Oscillator to generate precision synchronized CTCSS tones.

The master oscillator must be equipped with the appropriate option 14 output. There are 2 versions of the 1118; the 1118-2 a version with an enclosure, and the 1118-1, a rail mount version. This manual lists the pins and connectors for the 1118-2 first, then the pins and connections for the 1118-1 in brackets [].

1.1 FEATURES The Spectracom CTCSS Tone Generator offers the following features:

Accuracy: Continuous self-calibrated to GPS provides +/-1.0 x 10.1 frequency accuracy.

PTT input and an adjustable delayed PTT output.

" TIA compliant CTCSS reverse burst.

" Inhibit input that disables CTCSS tone generation.

Section 1: Specifications 1.2 1.2.1 1.2.1.1 Signal:

SPECIFICATIONS OUTPUTS STANDARD CTCSS FREQUENCY OUTPUT (CONTINUOUS TONE CONTROLLED SQUELCH SYSTEM) 67-254Hz sinewave derived from GPS disciplined oscillator with configurable 180-degree inverted "reverse burst" tone during delayed PTT output. See table 1-1 for tone frequencies and H1 jumper position.

Connector:

Signal Level:

Source Impedance:

Harmonics:

12 pin pluggable header J4 pins 6 and 7 [ or 6 Pin Header J6 pin 1, and 3 Pin Header J5 pin 1].

Adjustable with a potentiometer from 0.0 to 4.0 volts P-P (1.4 Vrms) into 600 ohms.

33 ohms 25dB below the CTCSS fundamental minimum 25dB below the CTCSS fundamental minimum CTCSS tones are gated by PTT with a configurable PTT hold or millisecond reverse burst.

Spurious:

PTT Operation:

DATA SYNC DATA SYNC LOOP THRU DATA CLOCK 0

0=0 0

INPUT OUTPUT INPUT 0

-1..

I - f ow

- 0.25 TYP.

4.43 3.93 L---u III

-nfl-u

...n -

()SPECTRACIM CTC88 FILTER

'Zr

(

0.25 4.03 0.63-5.28

Raytheon JPS Communications SNV-12 Signal-To-Noise Voter

" Independent DSP Inputs Vote the Best Voice or Data Channel.

" DSP Signal-to-Noise Ratio Determination for Each Site Input.

" Up to 12 Site Inputs Voted Per Chassis.

" Console Interface Module Interfaces with Industry Standard Dispatch Consoles

" Multiple Types of Repeater Control and Transmit Steering Capability.

  • Provides Tone Keying and Repeat Mode.

" Digital Delay Compensates for Differences in Link Paths.

" Local Control plus Parallel and Serial Remote Control.

" System Expansion to 36ZSites by Daisy-Chaining Multiple SNV-12s.

" 5.25" High by 19" Wide Rack-Mount Modular Card-Cage Package.

The SNV-1 2 uses separate Digital Signal Processors (DSPs) to continuously select the receiver with the best Signal-to-Noise Ratio (SNR) from multiple remote sites. This is a vital function in two types of applications. The first is a two-way radio application in which mobiles and portables can hear a repeater, but the repeater can not always hear the mobiles and portables.

By positioning remote receivers in the communi-cations deadspots, audio from each receiver can be linked to the voter via: microwave, landline, twisted pair or fiber optics. With the unit provid-ing the "voted" (best SNR) output to the repeater for rebroadcast, all mobiles and portables can hear each other since the repeater can hear them all. The second application involves a critical message sent simultaneously via several trans-mission mediums, or by several transmitters on different frequencies in the same frequency band.

In this "Diversity Reception" application, the mes-sage is picked up by multiple receivers while the SNV-1 2 always selects the signal with the best SNR at any given moment.

SN-1 SinlT-os Voter DSP Voting The Site Voter Module uses aspectral approach to continu-ously measure the Signal-to-Noise Ratio (SNR) of the audio signal received from each receiv-er site. The signal amplitude is measured by a JPS proprietary speech detection and measure-ment algorithm. Noise is meas-ured separately by the same algorithm. The SNR result is cal-culated by dividing the signal amplitude by that of the noise and operates from -6 dB to +36 dB in approximately 1.4 dB steps.

The SNV-12 continuously checks all inputs and ensures that the best SNR signal is voted. Thus, even if the signal is emanating from a moving vehicle, the SNV-12 will output the best signal at all times.

Voting voice signals allows tran-sitions in mid-syllable without harm to the intelligibility, but when voting data, transitions from one receiver site to another causes bit errors and synchro-nization problems. Thus, to vote data, the Site Voter Modules make a decision initially on the best data signal and then lock onto that receiver path until the data transmission is complete.

Data voting algorithms and soft-ware are special order options to the SNV-12, since the Site Voter Modules must be equipped with software defining the data's char-acteristics for the spectral meas-urement of SNR. The DSP SNR determination makes the SNV-12 an extremely accurate selector of the best available voice or data channel.

Local and Remote Control Front panel switches and status LEDs offer local control of the unit by allowing receiver sites to be forcibly selected, disabled and monitored. The SNV-12 provides both parallel and serial remote control, so interfacing with a PC or with any of a variety of indus-try-standard dispatch consoles is straightforward. Fault indica-tors on each of the modules pro-vide quick warning of problems.

A faulty Site Voter Module is automatically and immediately removed from voting considera-tion. A front panel speaker and headphone jack on the Console Interface Module allow continu-ous monitoring of the currently voted receiver audio.

Repeater Control When controlling a repeater, the SNV-12 offers three means of producing the necessary COR signal. Two of these approaches are common in public safety applications since both offer a quick method of detecting a faulty remote receiver or a faulty link. In the first, the voter pro-duces a COR output signal for the repeater which is derived from COR inputs provided by each remote receiver. In the sec-ond case, the voter's C0R output is derived from the absence of pilot tones (line proving tones) which each remote receiver pro-duces until it becomes unsquelched. Pilot tone frequen-cies of 1950 Hz, 2175 Hz and 2700 Hz are supported; others are available on special order.

The other approach is less com-mon: remote receivers are squelched when not in use and the DSP uses its voice recogni-tion algorithm to issue the COR signal.

MOBILE MOBILE phone line, microwave link, or twisted pair MOBILE I

SNV-1 2 VOTED RCV PTT MOBILE Repeater System Using the SNV-12 Voter with 12 Receivers Raytheon JPS Communications

SNV-12 Signal-To-Noise Voter BASE RCV AUD 2 Remote Transmitter Associated With Voted Receiver Used For Reply to Remote Mobile System Expansion Two additional SNV-12s may be connected to the first, each expanding the number of voting sites by up to twelve additional inputs. This expansion capability is implemented by daisy-chaining one SNV-12 to the next via rear panel connectors, up to a practi-cal maximum of three chassis or 36 site inputs. Signals between master and slave units include a serial data bus which allows one SNV-12 to exchange information with the next one in the chain. A Voted Audio bus transfers the best voted audio signal between units.

Transmit Steering In transmit steering applications, the transmitter associated with the current best voted receiver is used for a reply to a nearby mobile or portable radio. In this situation, the CPU Module pro-vides for automatic routing of console transmit audio and key-ing information to the proper remote transmitter site. If auto-matic transmitter steering is enabled, this module keeps the proper transmitter selected until the reply is complete and a new receiver site is voted. In manual-ly controlled applications, the dis-patcher decides which transmit-ter site to use for reply by issuing a Transmit Select signal to the proper Site Voter Module. The Voter can also group multiple voted receivers around separate remote transmitters. Tone Keying operation and Repeat Mode (Voted Site Talkthrough) are also provided within the Transmit Steering function.

Modular Packaging The SNV-12 is packaged in a 19" wide EIA standard rack-mounted Eurocard cage equipped with a backplane board. A Power Supply Module, Console Interface Module, CPU Module, and two to twelve Site Voter Modules are plugged into the card cage back-plane. Remote receiver signals are connected to the Site Voter Modules via barrier terminal strips on the backplane board for ease of hook-up. Each plug-in module has a front panel handle for removal and insertion. The unit is designed for hot plugging so that any module in the chassis may be inserted or removed with power applied without damage mfytheon JPS Communications

SNV-12 I

Sin lT-s Voe SPIECUFDCAT1OIMS Input Impedance Balanced or unbalanced 600 Ohms or 10k Ohms.

Input Level

-30 to -10 dBm, adjustable.

Frequency Response 200 to 3200 Hz + 2 dB.

Minimum Pilot Tone Sensitivity

-25 dBm.

Output Balanced 600 Ohms.

Output Level

-20 to +11 dBm, adjustable.

Frequency Response 200 to 3200 Hz +/- 2 dB.

Absolute Output Delay Less than 10 msec.

Distortion Less than 1%, 200 to 3200 Hz @ 0 dBm.

Switching Time Between Sites Less than 1 msec.

Unselected Output Rejection Greater then 60 dBm.

Output Impedance Balanced 600 Ohms.

Voting Threshold 1 through 7 dB in 1 dB steps.

Voting Delay 0 to 5 sec.

Input Impedance 22k Ohms pullup to +5 VDC.

Threshold

+2.5 V nominal.

Input Signal Range

+30 VDC.

Protection Up to 200 VDC.

Output Type N-channel open collector transistor.

Maximum Sink Current 100 mA.

Maximum Open Circuit Voltage

+60 VDC.

Audio Delay Serial Port Power Supply Front Panel (PSM-1)

Console Interface Front Panel (CIM-1)

Control Processor Front Panel (CPM-1)

Site Voter Module Front Panel (SVM-1)

Rear Panel AC Input Power DC Input Power Size Temperature Humidity Shock' Vibration 0 to 450 msec in 30 msec steps.

RS-232 DCE connector (female db9). Baud rates: 300, 1200, 2400, 4800, 9600, 19200, 38400, and 57600.

Power on/off Switch; AC on LED, DC on LED, +12 VDC LED, -12 VDC LED.

Speaker, Speaker on/off Switch, 1/8" Headphone jack, Volume control, Norm audio level LED, Peak audio level LED, Fault LED, Remote LED.

Master LED, Slave 1 LED, Slave 2 LED, Fault LED.

Disable Switch and LED, Select Switch and LED, Voted LED, Unsquelched LED, TX LED, Fault LED.

DC fuseholder, AC filter module, Connectors to interface up to 12 site voter modules, Serial remote connector, Console interface connector, and Expansion connector for daisy chaining SNV-1 2s for voting of up to 36 sites.

115 or 230 VAC _+ 15%, 47-63 Hz, 100 VA typical, 130 VA maximum.

+11 to +15 VDC @ 5 A, nominal.

5.25" H x 19" W x 11" D (13.3 x 48.3 x 28 cm).

Operating: -20 to +60 degrees C. Storage: -40 to +85 degrees C.

Up to 95% @ 55 degrees C.

MIL-STD-810D, Method 516.3, Procedure VI.

MIL-STD-810D, Method 514.3, Category I.

JPS Communications, Inc.

5800 Departure Drive Raleigh, NC 27616 Phone: (919) 790-1011 Fax: (919) 790-1456 E-Mail:ijps@jps.com Web: www.jps.com Specifications subject to change without notice.

NXU-2T 1 is a trademark of JPS Communications.

Copyright © 2003 JPS Communications.

All rights reserved.

Ver.1 8/21/03 JPS Communications

T1/E1 Copper to Fiber Remote In-Band Management Stand-Alone Media Converters SSDTFxOxx-lxx Convert Copper to Fiber o Provide Campus Interconnects IUEI III! I U1IUIIUIOI Ti/El POX cilab From Ion mlfi TI/El Media From 2 kmn mellmode CISon la Upt*o km Ir single mode

~T101 Me T1-E1 Media TI/E1 5,000 ft.

Convete i Remote Management i Extend T1 Networks

-Build-Ing I 1 I

EirkcswI* $T T1 1 NOW L-------------------1--

from 2kan munlmede lifer up to Billio single mode fiber F

2 mot ltutmBuinnlding 2 A ý web Ti/El PBX"........

Sie L

T R A N S-rl T I0 ýN The Conversion Technology Exports Transition Networks, Inc.

6475 City West Parkway Minneapolis, MN 55344 USA

©2005 Transition Networks, Inc.

All trademarks are the property of their respective owners.

Technical information is subject to change without notice.

tel 952.941.7600 or 800.526.9267 fax 952.941.2322 info@transition.com http://www.transition.com

Ordering Information: T1/E1 Stand-Alone Media Converters Product Number Port One SOTIF1MI-1U Twisted Pahr RlJ-48) 1 5liko/0 ImiI SSDTF1013-105 Twisted Pair (RJ-48)

P1 5 km/O 9 mi SSP1086 Twigleed

Pair, SSDTF1027-105 Twisted Pair (RJ-48)

[1 5 kmiO 9 mi I

.tnt SSOTF1022-105 Twisted Pair (RJ-48) 1 5 km/O 9 mi I 8513W8l94-1E1 ite Pair SSDTF1012-105 Twisted Pair (RJ-48)

I1 5 kmi mimI St~OTrtIOI-I1 R1 SSOTF1021-105 Twisted Pair (RJ-48)

[1 5 km/i 9 mi I Port Two 850hm mulftimode ST) 85Into /12multimod 850nm multimode

( SC) 12 kmr

/ 1.2 miles) l380tap multiminIde 1300nm multimode ST) 15km /3.1 miles]

1310nm single mode (ST)

IliOnm~kte 1310nm single mode (SC) 40 km/24 m Ies 1310nm sr 1550nm single mode (SC)

[40 kTi ml est]I Product Number Por One 8601V30I16-1 cm SSDTF3013.115

2) Coax (BNC) 100 m / 328 ft.)

SSOTF31S-1l5

12) Coax (ONC)

SSDTF3027-115 (2) Coax )BNC) 100 m/ 328 ft.

9SUD II-115 2 Coax l

SSDTF3022-115 (2) Coax (BNC)

[100 m / 328 ft]

SSDTF3015-115 (2) Coax (BNC) 1100 m /328 ft.)

SSDTF3017-115 (2) Coax (BNC) 100 m / 328.1 Port Two 850m ouridmode 2 1e/1.2 mies!iul 850nm multimode (SC)

(2 km 11.2 miles) 130D0m mullirimtde 2m/ 12 miles) 1300nm multimode iST)

[5kmI / 3.1 miles]

110turnt single mode (ST) 1310nm single mode (ST) 131Onm single mode (SC)

[40 km/24.9 miles]

l310nm single 1550nm single mode (SC)

'Pi kri.; 4 fio r SSDTF1029-105 Twisted Pair 1310nm TX/

(RJ-48) 1550am RX single 11 5km/n 9 mi.)

fiber single mode SC) 20 km/124 miles)

SSWTF1029-107 Twisted Pair 1310nm TX/

(RJ-48) 1550nm RX single 11.5 km/Oi 9 mi I fiber single mode SC) 40 km/24.9 miles]

S I

1 s

Pair ur*

I i

z) IUX(W" uo i

,*~]

I-1100 1 / 328 1.

155Onto RX single fiber single mode (SC)

[20 km/12.4 miles]

SSD1T3028-117 (2) Coax )BNC) 131in TX/

[10m /328 ft.)

1550nm RXFsingle fiber single mode SC) 40 km/24,0 miles)

SSTM 11 2CaxH (BNC 150mX fiber s

ine Iý40 W2.

mles]

Specifications Standards ITU-T, ANSI, AT&T, ETSI Fiber Optic Connector Specs SISIM11l1-14uII Min TX PWR: -19.0 dOm SDS1a*013l Max TX PWRt

-14.0 d~m RX Sensitivity: -32.5 dBM M

PWRINK-00dB Link Budgets 115 d

-S0DTFx1O14 M PWR-1.0dBm AX SeonsfiilMy:-30.0 d~t Max n PWR:

-14.0 dOrn Link Budlget:

1.0 d8 SSDTFx27lx5 MinTXPWR-04m RX Senstivity: -3Z5 Bomn Max In PINK -14.0 d~m Unk Budget 13.5 dB SSDTFxg#2?495 liei TX PAR: -27.0 d0m Matx TX PAR: -10.0 dBm AX Sensifivity -34.0 d~nt Max In PWII -14.0 d~n Llnk Budget: 7.0 dB SSEIlFA0?2 IinS Mml TX PWII: -20.001885 Max TX PWA-50dem RX Sensitiity -5. dm Link Budget 15.0 dB sortll4al/

Min TX PW Ln

-15.0 see onk Budget Hul dB 9LM415A*id

)NoTX Pli-8. d~m Max1TX Pos4

-20 usdm XSW2-1ernsiti ity

-38.

ons nt Maxpe In Pilos -of fiBerlnm U LinaBuedge:00dB Swites SWi - 2.

T3 Lnemitld outs for shofbrt au/oin Long Hau (spee kU t iabled)

SW2 - 1 Trnsmit allr ones int coppe on lossý

-7t f~ibrlin U

~ p = Short Haul)

W2 -4 Ti/E1 selection (Up = Ti) 3R X

J m n ptyr:

-3 6.0ee e r m o d Status LEDs PWR Powert Steady green LED indicates connection to ettemal AC power SOC Sinai Dget:cCoppert on indicates twisted pair link is up SDF BSugn Detect:F2ber.

d O

indicates fiber link is up Power External AC/DC provided; 12V DC;

.SA; unregulated; standard; UL listed Shipping Weight 2 lbs. [0 9 kg]

Regulatory ClSP TrEN55022 Class A, Compliancn FCC Class A, CE Mark Waniw

= Dialed)n tel 952.941.7600 or 800.526.9267 fax 952.941.2322 info@transition.com http://www.tra nsition.com Switch Settings Long Haul (SW1-3 unused)

SWl-t SWt-2 Dowe Down Od output pulse Up Down

-7.5db output pulse Down Up

-lboutputpulse Up Up

-22 5db output pulse SbaetaiHl18#1-4 unsll

- Optional Accessories (soldseparate/y) -

Product Number Description SPS-1172-PS W~ide[

ut (-72VDG) Piggy Back SPS-1872-SA Wide Input (18-72VDC) Stand-Alone Power Sapply E1, 044 12-Slot Media Converter Rack WMBD DIN Rail Mount Bracket 5.0" [127 mm)

WMID-IF DIN Raia Mount Bracket (fnat) 3.3" [84 rmn]

WMBL Wall Mount Bracket 4,0" [102 mm 5mEO Vertical Wail Mourn Bracket 5.0" [27 111 SWi-1 Up Down Up Down Up Up Down SWi-2 Up Down Down Up Up Up Up SW1-3 Down Up Up Up Up Down Down DSX-i. 0-133 ft.

DSX-1,133 - 266 ft.

l3$X-1, 2866-399ft.

DSX-1, 399 - 533 ft.

NSI-1, 503-8655f

ANSI, Ti.403 DSX-1, 6,0V T R AN Sr"

,;;00;Oo*

n e t w o i k S, The Conversion Technology Experts Transition Networks, Inc.

6475 City West Parkway Minneapolis, MN 55344 USA

©2005 Transition Networks, Inc.

All trademarks are the property of their respective owners.

Technical information is subject to change without notice.

i4-E IREMOTE-LOOP i ADACDPOUC ETRS&-ETFCTO Loopback Select Transition Networks products are equipped with Loopback. This feature puts a converter in a special mode that enables the device to loop back the signal from the RX port to the TX port on either media for testing and troubleshooting purposes. Test signals from a tester (Firebird, etc.) can then be inserted into the link and looped back as received by a device to test a particular segment of the link (i.e. copper or fiber).

Loopback can be either local or remote depending on the location of the converter in the link.

I Allows network diagnostics from local or remote location P Quickly pinpoints problem areas of end to end link by testing a particular segment r,,t. CA,,WW up If someone tolls you <media conversion is a commodity product that anyone can bring to market, they prob~ably haven't looked at the extensive product suite offered by Transition N~etworks. With the ndustrys most comprehensive offering of full-featured products, Transition's media converters stand out as 'the choice' among industry IT professionals.

Generally, media converters ar.e tow-level OSI model devices wihn Por MtAC addresses and therefore re transparent to them very iepnveand easy touse, but very ifficutt. Inan effort to overcome this difficulty and to make media converters

'~visible' to network managers, Transition haes designed their full-featured products to include the most advanced features on the market today.

xWENOWN

"-?,

Fm g*odtw Some converters have separate copper and fiber loopback functions that can be enabled separately, while others will loopback both copper and fiber at the same time when enabled. Please refer to the specific product page for details.

l Remote Management All chassis-based converters from Transition Networks can be managed through SNMP. Now, select stand-alone products can also be managed through SNMP when used in conjunction with a chassis based converter. While chassis based products are generally placed in the telecommunications room, stand-alone converters are generally placed in remote locations away from network administrators. Remote in-band management over fiber allows administrators access to the remote device to check status and enable/disable features or the device itself.

Visibility of remote converters for network administrators Allows for centralized management of media converters

' Single Fiber Single fiber technology offers a 50%

savings in fiber utilization. It is an attractive solution to maximize the usage of a limited number of fiber runs.

In a traditional optical link, a fiber pair consists of two uni-directional strands.

The single fiber technology multiplexes two optical wavelengths of 1310nm and 1550nm into a single strand fiber. In a single fiber media converter each wavelength is responsible for either the transmit or receive function.

Consequently, the bi-directional transmission is achieved by using a single strand. The converters in a single fiber scenario "match" each other's wavelengths. Converter A transmits at the wavelength of 1310nm and receives at 1550nm while the other converter transmits at 1550nm and receives at 1310nm. Therefore, converters are usually used in pairs.

Single Fiber TX(ll3%m)

RX(l$13nmi U~ l~gin IXlIAm RX (1550li)

TX (1558nlem)

Single fiber technology is available on all Transition Networks Media Converters in maximum distance ranges from 20 to 80km.

T R A N S-r'-rT m0 N

0010n e I w o k

The Conversion Technology Experts Transition Networks, Inc.

6475 City West Parkway Minneapolis, MN 55344 USA

©2005 Transition Networks, Inc.

All trademarks are the property of their respective owners Technical Information is subject to change without notice.

tel 952.941.7600 or 800.526.9267 fax 952.941.2322 info@transition.com http://www.transition.com

Features

@ Fast Ethernet--Scalable from 25 Mbps to 100 Mbps

& Scalable to up to_16'T1 /E1s i--Sclable and Spectrally Efficient I. SM 5.8 Ghz Unlicensed Band

  • UNII 5.3GHz Unlicensed Band

." Adaptive Power Control

,* Easily Deployed and Activated

. Ririg Architecture Minimizes, Interruptions Applications Conrnect Buildings, Campuses, e

  • Backhaul/Extend IP Networks, S

,; Utility Mo-ritoring, Contliol, Data Network Aggregation

  • Eliminate Monthly Leased Line F Means Quick ROI MDS...Global wireless solutions. Ondustrial Wireless Performance.

For nearly two decades, Microwave Data Systems (MDS) has been providing highly secure, industrial strength mission critical wireless communications solutions for a broad spectrum of public and private sector clients worldwide. With an installed base approaching 1,000,000 radios in 110 countries, MDS offers both licensed and license-free solutions with applications in SCADA, telemetry, public safety, tele-communications, and online transaction markets.

Introduc'in DS FIVE.S TM and MDS FOVI.3 TM The MDS FIVE Series consists of an open front/rear Software Defined Indoor Unit (IDU) and Outdoor Unit (ODU). The MDS FIVE Series radios are spectrum and data rate scalable, enabling utilities or other organizations to trade-off system gain with spectral efficiency and channel availability for optimal network connectivity. The MDS FIVE.8 TM radio delivers aggregate rates up to 200 Mbps within the 5.7 - 5.8 etc.

GHz ISM band for distances of up to 20 miles. The MDS FIVE.3TM is also available

ANs supporting the 5.25 - 5.35 GHz UNII band. A common platform supports plug-in
  • 100 Mbps Ethernet.

Why use an MDS FIVE Series Solution?

ees

  • Quick return on investment-replaces leased-lines.

e Consecutive point architecture configurable--able to support a ring/consecutive point configuration with special set-up (see diagram on back of data sheet).

Self-healing redundancy-more reliable than traditional point-to-point networks.

a Automatically adjusts transmit power in response to RF interference, simplifying deployment, network management, and enabling dense deployment.

x

/I I

ZI INDWUST R21AL WIELESS PERORAC

I A

6" S

MODEL J

THROUGHPUT DATA' INTERFACE WAYSIDE S

MSfIVE Series - 050 100 Mbps Aggregate 100 Base TX Two TI/Els (50 Mbps full-duplex)

M0S FIVE Series-200 Mbps Aggregate 100 Base TX Two TI/Els (100 Mbps full-duplex) 0SF-VE'S&hd---160 70'-200MbjWM**Agg-at e--

l-167T1iE5

-m-

.--tsfableEthlr-t (35-100 Mb*s full duplex)

'I General Frequency Range Average Output Power Max EIRP Capacity Options Modulation FEC Receive Sensitivity Antenna Gain Antenna Connector Distance Power Encryption*

Protected Option' FIVE.8 (ISM)

FIVE.3 (UNII) 5,725 - 5,850 MHz 5,250 - 5,350 MHz

-8 to 23 dBm RMS

-18 to +13 dbm RMS

+46 dBm RMS (with

+30 dbm integrated antenna)

Ethernet:

Spectrum scalable from 25 Mbps to 100 Mbps full duplex

+2 TI/E1 Wayside Channels

OPSK, 16-OAM, 32-0AM, 64-DAM Trellis Coded Modulation concatenated with Reed-Solomon Coding 100 Mbps 25 MHz:

-67 dBm 50 Mbps 25 MHz (50FE2):

-73 dBm 25 Mbps 25 MHz (25FE2):

-79 dBm 16 T1 25 MHz:

-79 dBm 16 El 25 MHz:

-77 dBm 23 dBi (integrated antenna)

N-Type Female for optional external antenna Up to 20 miles (or greater, depending on antenna)

-48 volts +/- 10%, <70 watts; Optional 100-240 Volts AC, 47-63 Hz power supply Encryption based upon a 128-bit key is available for select markets and is applicable for the MOS FIVE Series -50 and

-100 products only Configurable for 1+1, hot standby, hitless switching, spacial diversity (not for diversity combining)

'Data Interface Continued Compliance Ethernet:

IEEE 802.3 NxEI/Ti: ITU-T Auxiliary Connections Wayside Channels Tl/E1 Interface DSX-1 Connector RJ-48C Alarm Port

- 2 Form C relay alarm outputs, 2 TTL outputs Voice Service Channel

- 6 wire, PTT handset Network Management Support

- Network management config. tool

- SNMP vi, 2, 3, and web-based config.

- Built-in Web browser Connector RJ-45, l0/lOOBaseTX Environmental Temperature IDU -50 to 55°C (320 to 1317F)

ODU -30° to 55°C (-22' to 131°F)

Humidity IDU: 0 to 95%, non-condensing ODU: Up to 100% at 45°C (113°F)

Altitude IOU/ODU: 4500 m (14,100 ft.)

Mechanical Size IOU: 1RU, ETSI Compliant 17.5 x 9.4 x1.75 inches (445x238.5x44.5mm) rack mount 19 inches, (48.2 cm)

ODU: 15.7 x 14.5 x 2.1 inches (39.9x36.8x5.33cm)

Weight IDU: 7 lbs. (3.17 kg)

OOU: 15 lbs. (6.8 kg)

Agency Approvals FCC approved IC approved Data Interface Physical Connector iOOBaseTX Full duplex El/T1 Ethernet:

RJ-45 NxEl/TI:

2xRJ-48C, HD60 FIVE Series Simplified Ring-Architecture Diagram (6 units needed - consult factory for details)

Outdoor Unit Indoor Unit Indoor Unit

  • Release //
  • cfia>

Microwave Data Systems Inc.

175 Science Parkway Rochester, New York 14620, USA Phone (585) 242-9600 Fax (585) 242-9620 www.microwavedata.com MIDS products are manufactured under a quality system certified to ISO 9001. MDS reserves the right to make changes to specifications of products described in this data sheet at any time without notice and without obligation to notify any person of such changes.

© 2005 MDS Inc. (MDS FIVE Series SLO124) Rev. B, 03-06-06 INDUSTRIAL WIRELESS PERFORMANCE

Th RX eisa piir are

~

orm st ouarcs efetie cninu u

I ut po e

am lfer.T i

pacag wil acet5 n

I IS S

1N SI m

lferfo o

ban S

hog 96 M

z witgi oupu levels*

up Io 150 watt I

Th vetia fispo vid exeln con

  • `,

0

' I w

  • , r S

nt

- ertca rack spac p an I aIIowigi V

S u.......

fcin r

airfo wit I

he1-.,,.1 doo clsed I

_'ý am lfir have S

-irciSrekr Powermpies RXR RVRF S

RXR Amplifier Series COMMUNICATIONS Employee Owned Company

Power Input Power Output Frequencies Voltage Current Harmonic Attenuation RF Connectors Operating Temperature Duty Cycle Weight Configuration Standard TPL amplifier input levels, optional to 1 0mW or less.

50 to 150 watts.

VHF Low Band, VHF High Band, 220 MHz, UHF, 700-960 MHz.

13.8 VDC, 120 or 240 VAC (24 VDC or 48 VDC available).

5-24 Amps DC/1 -4 Amps AC.

Exceeds FCC specifications.

Type N, 50 Ohms.

-30 to +50 degrees C.

Continuous (100%).

7 lbs., 14 lbs., w/power supply.

19" W x 7" H x 3" D (without fan) 19" W x 7" H x 5" D (with fan).

8" D w/power supply.

  • Cooling fan provided for power levels exceeding 80 watts.
  • Accommodates all bands from 35 to 960 MHz.
  • Vertical fins for efficient convection cooling.
  • 100% duty cycle operation.
  • Repeater or base station operation (with bypass relay option).
  • 19" rack mountable configuration.
  • Available with or without self-contained switching power supply.
  • Front panel circuit breaker/on-off switch.
  • Flat front panel allows for cabinet door closure.
  • Cost effective design.

3370 San Fernando Road, #206

  • Los Angeles, CA 90065-1437 (323) 256-3000. (800) HI POWER. FAX (323) 254-3210 Emailh sales@tplcom.com - www.tplcom.com Specifications subject to change without notice.

2i

Assembled Trunking System Base Station/Repeater Portfolio PassPort' LTR' and Conventional Compatible An increasing number of forward-thinking businesses are utilizing the power of trunking for their two-way radio communication. Cost-effective and efficient, LTR and PassPort trunked communication provides wide calling range, great privacy, and fast channel access to help workers connect without delays-as well as high user and talkgroup capacity to enhance system efficiency. And by purchasing their own trunked systems, companies can gain the control and flexibility they need to keep costs low and communication quality high.

Motorola delivers all the expertise and equipment required to create a fully functioning, integrated two-way radio trunked network-quickly and easily. Your choice of repeater components below provides your business the coverage and capacity flexibility of the Motorola Assembled Trunking System (ATS).

Radius R1225M/RKR1225T3 Ideal for desktop use in an office setting, the R1225/RKR1225 can also become a base station allowing a dispatch operator to communicate with other radios in the field. It has built-in basic repeater capabilities.

Optional controllers can be added for enhanced features such as telephone interconnect, multiple PL/DPL codes and signaling.

Available in UHF (444-474 MHz) and VHF (146-174 MHz)

"Limited" QuantarTM The "Limited" Quantar Station/

Repeater helps maximize system up time by providing reliable solid state performance and self-testing capabilities. Available in 110-25 Watt or 100-25 Watt variable models, the "Limited" Quantar is also available with battery reverting to help maintain system operation in the event of a site power failure, Available in UHF (470-494 MHz and 494-520 MHz)

MTR20ff TM The MTR2000 Station/Repeater provides unmatched flexibility in a compact design. This product offers features such as Tone Remote Control and continuous duty cycle operation. In addition, the MTR2000 unit is available in 100-25 Watt, 40-2 Watt, and 30-2 Watt variable power models.

Available in UHF (403-470 MHz) and VHF (136-174 MHz)

MX800 The MX800 Base Station Repeater, manufactured by Spectra Engineering Pty, is the repeater component intended for use in Motorola's PassPort and LTR ATS systems in 200 and 700 MHz frequency bands.

Offering wide RF switching bandwidth with superior blocking, intermodulation, and adjacent channel performance, the MX800 also comes with fully welded steel housing, a built-in NTS Trunking Controller interface, and provides a 50 Watt power output.

Available in 200 MHz (217-221 MHz) and 700 MHz (746-764 MHz)

Limited product specifications appear on the reverse of this sheet. For full product information and specifications, please refer to the dedicated product and specification sheets.

Base Station/Repeater Portfolio Specifications R1225/RKR1225 R1225/RKR1225 MTR200O MTR2000 (Quantar Limited Spectra MX800 Spectra MX800 VHF UHF VHF UHF UHF 200 MHz 700 MHz Model Number 1-16W: M03GRC 1-10W: M04GRC T5766. T5769 15766. T5769 C99ED/061C Factory ID: T5365 DON6725 DDN6726 25-50W: M436RC 25-45W: M44GRC Frequency 146-174 MHz 444-474 MHz 132-174 MHz 403-470 MHz 470-494 MHz, 494-520 MHz 217-222 MHz 746-794 MHz Adjustable RF Power Output 1-10 Watts or 25-50 Watts X345 (132-174 MHz) 30 Watts X341 (403-470 MHz) 30-2 Watts X640 (470-494 MHz) 110-25 Watts 5-50 Watts X330 132-174 MHz) 40 Watts X340 (403-470 MHz) 40-2 Watts X640 (494-520 MHz) 100-25 Watts X530 132-154, 150-174 MHz)

X540 (403-435 MHz, 435-470 MHz) 100 Watts 100-25 Watts Channel Spacing 12.5/20/25/30 kHz 12.5 kHz/25 kHz/30 kHz 12.5 kHz/25 kHz-12.5 kHz/25 kHz 12.5 kHz RF Channel Capacity up to 16 up to 32 up to 32 up to 16 up to 255 Mode of Operation Full Duplex Simplex!Semi-duplex!Duplex Full Duplex Full Duplex Full Duplex Duty Cycle Continuous @ 25W and 1-10W 14.2 VDC (40/30 Watt Station) 14.2 VDC (40/30 Watt Station)

Continuous Continuous transmit with thermally controlled fan 50% @ 45/50W IS min. on/5 win. standby) 28.6 VDC (100 Watt Station) 28.6 VDC (100 Watt Station)

Dimensions 5,25" x 19" x 13.5' (133 x 482 x 343 mm) 5.25x19"0x 6.5"(133x483x419mm) 5.25"x19"x16.5 (133x483 x419 mm) 8.75" x 19" x 17" 3.6" x 19" x 13.2" (2RU high. 19" standard rack mounting)

Weight 22 lbs. (10 kg) 40 Ibs. (19 kg) 40 Ibs. (19 kg) 55 hbs.

(25 kg) 19.0 Ibs. (9 kg)

Applies to station with option X87 Omit Cabinet without triple circulator option Temperature Range

-30° C to +601 C

-30° C to +601 C

-30° C to +600 C

-30° C to +601 C

-10° C to +60o C (reduced specs from -30' C to -10' CQ R1225/RKR1225 R1225/RKR1225 MTR2000 MTR2000 Qutantar Limited Spectra MX800 Spectra MX800 VHF UHF VHF UHF UHF 200 MHz 700 MHz Frequency Range 146-174 MHz 444-474 MHz 30 Watt: 132-174 MHz 30 Watt: 403-470 MHz 470-494 MHz 494-520 MHz 217-221 MHz 746-764 MHz 40 Watt: 132-174 MHz 40 Watt: 403A470 MHz 100 Watt 132-154 MHz. 150-174 MHz 100 Watt: 403-435 MHz, 435-470 MHz Frequency Stability

+/- 2.5 ppm (-30' C to +60' C)

+/- 1.5 ppm (-300 C to +600 C) 1.5 ppm/ External Ref 1.5 ppm/ External Ref 1.5 ppm/ External Ref (Optional)

+/- 2.5 ppm

+/- 1.0 ppm FM Deviation

+2.5 kHz Spurious

-23 dtm

-85 dBc

-85 dBc 90 dB

-90 dBc Audio Distortion

< 3% EIA (@ 1000 Hz 60% rated maximum deviation)

< 3%

<3%

< 2% 1000 Hz @ 60% RSD

< 2% EIA FM Hum and Noise 20/25/30 kHz -45 dB Normal 20/25/30 kHz -45 dB Normal 300 to 3000 Hz bandwidth, 60% RSD, 300 to 3000 Hz bandwidth, 60% RSD, 300 to 3000 Hz bandwidth, 60% RSD.

12.5 kHz: -44 d1 Typical 12.5 kHz: -40 dB Normal 12.5 kHz: -40 dB Normal 30 (VHF) 25 kHz: 50 dB Normal 30 (VHF) 25 kHz: 50 dB Normal 750ps de-emphasis 25 kHz: 50 1

12.5 kHz: 45 dB Normal 12.5 kHz: 45 dB Normal d1 Normal 12.5 kHz:

45 dB Normal Emission Designators 12.5 kHz: 11KOF3E 25 kHz: 16KOF3E.

13K6F1D.

13K6F1D 25 kHz: 16KOF3E.

13K6F1D 16KOF3E.

16KOFtD.

11KOF3E 20/25/30 kHz: 16KOF3E 12.5 kHz: 11KOF3E.

IFOKO D, 8K16F1D 12.5 kHz: 11KOF3E.

8K6OF1D 20KOF1E.

20KOF1D, 11tKOF3E.

8KIOF1E. lOKOFlD R1225/RKR1225 R1225/RKR1225 MTR2000 MTR2000 Quantar Limited Spectra MX800 Spectra MX800 VHF UHF.

VHF UHF UHF 200 MHz 700 MHz Frequency Range 146-174 MHz 444-474 MHz 132-174 MHz 403-470 MHz 470-494 MHz 494-520 MHz 219-222 MHz 776-794 MHz Frequency Stability t 2.5 ppm t 1.5 ppm 1.5 ppm/ External Ref 1.5 ppm/ External Ref 1.5 ppm/ External Ref (Optional)

+/- 1.5 ppm -100 C to +60 C: +/- 2.5 ppm -30' C to -100 C Sensitivity@ 12 dB SINAD 0.35pV (-116.1 dBm)

.35pV 0.35pV 0.35pV O.3pV (-117 dBm)

Selectivity 20/25/30 kHz: -85 dB 20/25/30 kHz: -80 dB 25/30 kiHz: 80 dB 25/30 kHz: 80 dB 25 kiHz: 85 dB 75 dB 65 dB 12.5 I-H: -65 dB 12.5 kHz: -65 dB-12.5 kHz: 75 dB 12.5 kHz: 75 dB 12.5 kHz: 75 dB Intermodulation

-80 dO (12.5 and 25/30 kHz) 80 dB/85 dB (12.5 and 25/30 kHz) 80 dB/85 d8 85 dB 80 dB Spurs and image

-85 dB 85 dB Nominal

-85 dB Nominal 100 dB 90 dB FM Hum and Noise 20/25/30 kHz: -45 dB Normal 20/25/30 kHz: -45 dO Normal 1000 Hz tone @ 60% RSD 1000 Hz tone @ 60% RSO 100 Hz tone @ 60% RSD 12.5 kHz: -44 dB Typical 12.5 kHz: -40 dB Normal 12.5 kHz: -4040 Normal 25 kHz: 50 d4 Nominal 25 kHz: 50 dB Nominal 25 kHz: 50 dB Normal 12.5 kHz: 45 dB Nominal 12.5 kHz: 4540 Nominal 12.5 kHz: 45 dB Normal MOrOROLA MOTOROLA and the Stylized M Logo are registered in the US Patent and Trademark Office. All other product or service names are the property of their respective owners.

@ Motorola, Inc. 2005. wwnwmotorola.com/cgiss 6880309S39

MXl n BdASE speiINatoPECIF AiIuONe Recently enhanced and updated specifications in blue.

Minimum performance to exceed the following for 30MHz to 960MHz*:

  • Conforms but not all bands approved.

AS4295-1995, R&TTE EC Directive 1995/05/EC, EN300 086 --1,2 (2001- 03),

EN 300 113, EN 301 489 - 1,5 (2002 -08),

EN 60950 (2000),

RFS25, RFS26, RFS32, TIA/EIA-603, BAPT 225 ZV 1/2098 (German soft keying),

FCC Part 22, 74, 90, 90.210, 80.475, MIL-STD-810E (Parts thereof),

GENERAL Frequency Range:

Coverage 30-960 MHz.

Band A2 Band A3 Band A Band B° Band C Band D3' Band E Band F Band H Band J Band J2 Band K Band L Band M Band N2' Notes:

30-39 MHz 39-50 MHz 66-80 MHz 70-88 MHz 135-160 MHz 148-174 MHz 177-207 MHz 195-225 MHz 245-275 MHz 295-325 MHz 300-337 MHz 320-350 MHz 345-375 MHz 370-400 MHz 400-435 MHz Band 02 Band P Band P2' Band QO Band Q2 Band R2 Band R3 Band R Band S Band T Band U Band V Band V2 Band W Band X 435-470 MHz 455-490 MHz 450-485 MHz 485-520 MHz 500-532 MHz 746-764 MHz 776-794 MHz 805-825 MHz 824-849 MHz 850-870 MHz 870-905 MHz 890-915 MHz 900-925 MHz 917-950 MHz 925-960 MHz

1. Band, Q2, R3 are RX only; R2, V2 are TX only.
2.

0 Standard Preferred Frequency Band.

3. Band A2, A3 have 4 MHz RX VCO Sw BW.

SPECTRA ENGINEERING PTY LTD 9 Trade Road, Malaga 6090 Western Australia Telephone: +61-8-92482755 Facsimile:

+61-8-92482756 Rev 10.0 August 2006 Web page: www.spectraeng.com.au e-Mail: info@soectraeng.com.au

MUX8O BASE STATION SPECIFICATIONS Synthesis Method:

Modulation:

System Deviation:

Channel Spacing:

Synthesizer Step Size:

Channels:

Supply Voltage:

Power Consumption:

Operating Temperature:

MX800 Size:

Standard LED indicators:

Non-mixing PLL.

Fractional N synthesizer.

Direct FM two-point method.

+/-5.0kHz max (WB), +/-2.5kHz max (NB)

Programmable 25kHz/ 12.5kHz, Special on request.

12.5kHz, 10kHz, 6.25kHz or 5kHz.

255 Software or switch selectable, 1-99 BCD or 255 Binary parallel selection.

13.8 +/- 20%.

<500 mA receive, typ 460mA. 220mA opt.

<10A for 50W TX RF output.

<17A for 100W TX RF output D3 band.

-30 to +60C, -30 or -40C test option.

2RU Case, 325mm deep including fan.

Power, RX, TX, CTCSS, Aux/Lock, Alarm.

TRANSMITTER MEASURED IN ACCORDANCE WITH TIA/EIA-603 STANDARDS RF Power Output:

Frequency Stability:

Audio Response:

Audio Bandwidth:

Modulation Distortion:

S/N Ratio below 700MHz:

S/N Ratio 700-900MHz:

S/N Ratio above 900MHz:

Spurii and Harmonics:

RF Switching Bandwidth Exciter:

RF Switching Bandwidth PA:

Duty Cycle:

RF Rise Time:

Typical Supply current (470MHz):

Typical Supply current for 100W output:

VCO Conducted Emissions:

VCO Radiated Emissions:

Adjacent Channel Power:

Transmitter IM conversion loss:

Automatic VSWR foldback:

Output Load Impedance:

Antenna connector:

I W to 50W variable. I W nominal UHF PA opt.

100W option, 5W to 100W variable for D3 band.

1.5PPM std, UHF. 2.5PPM VHF 20PPM VHF-Low. 1.OPPM opt 800MHz.

Flat within +1,-3dB across BW.

DC to 3400Hz (DC FM input).

300Hz to 3400Hz (VF input).

Less than 2% @ 60% deviation.

Better than 50dB (WB), 45dB (NB).

Better than 50dB (WB), 44dB (NB).

Better than 47dB (WB), 4 ldB (NB).

More than I 00dB below carrier.

Same as band allocation.

Same or greater than band allocation.

100% for 50W RF output.

4mS with continuous VCO selected.

50W:8.6A, 25W:6.2A, 15W:5A, 1OW:4.3A, 5W:3.3A, IW:2.1A.

15A. D3 band.

Less than -70dBm with TX off.

Less than luV/m @ 3m.

78dB (WB), 72dB (NB)

Better than 40dB Trips at nominal.VSWR >3:1 50 Ohms nominal (VSWR <2:1)

N-Type Female SPECTRA ENGINEERING PTY LTD 9 Trade Road, Malaga 6090 Western Australia Telephone: +61-8-92482755 Web page: www.spectraeng.com.au Facsimile:

+61-8-92482756 e-Mail: info@spectraeng.com.au Rev 10.0 August 2006

X8, 0 BASE STATIONý-

SPECIFICATIO RECEIVER MEASURED IN ACCORDANCE WITH TIA/EIA-603 STANDARDS Sensitivity for 12dB SINAD:

Sensitivity for 20dB SINAD:

Selectivity 30-50MHz:

Selectivity 66-88MHz:

Selectivity 135-520MHz:

Selectivity 700-900MHz:

Selectivity 900-960MHz:

Audio Bandwidth VF output:

Discriminator Output Bandwidth:

Spurious Response Immunity:

Intermodulation Immunity:

Blocking Rejection:

Distortion:

S/N Ratio below 700MHz:

S/N Ratio 700-900MHz:

S/N Ratio above 900MHz:

Co-Channel Rejection:

RF Switching Bandwidth:

Receiver Front End BW:

VCO Conducted Emissions:

VCO Radiated Emissions:

Input Load Impedance:

RF Input protection:

Antenna connector:

Receiver type:

IF Frequency:

Local oscillator Injection:

SPEE 9 Trade Road, Malaga 6090 Western Australia Telephone: +61-8-92482755 Facsimile:

+61-8-92482756 Rev 10.0 August 2006 Better than -I17dBm (0.32uV).

Better than -I l5dBm (0.40uV)

More than 90dB for 25kHz adj channel, more than 80dB for 12.5kHz adj channel.

More than 85dB for 25kHz adj channel, more than 75dB for 12.5kHz adj channel.

More than 84dB for 25kHz adj channel, more than 77dB for 12.5kHz adj channel.

90dB option available on special request.

More than 80dB for 25kHz adj channel, more than 70dB for 12.5kHz adj channel.

More than 75dB for 25kHz adj channel, more than 65dB for 12.5kHz adj channel.

300Hz to 3000Hz (+l,-3dB).

DC to 3400Hz (-3dB).

Better than 90dB.

Better than 82dB (WB), 80dB (NB).

Better than 110dB at +/- 1MHz point.

Less than 2% @ 60% deviation.

Better than 50dB (WB).

Better than 45dB (NB).

Better than 50dB (WB), 45dB (NB).

Better than 46dB (WB), 41 dB (NB).

Better than 5dB.

Equal to band allocation.

Equal to band allocation, no retuning.

Less than -70dBm.

Less than I uV/m @ 3m.

50 Ohms nominal (VSWR <2:1)

No damage at input +20dBm BNC Female, N-Type Female option.

Double Conversion Superheterodyne.

90MHz first, 455kHz second 70MHz first for band A3, 45MHz first for band A&B Low side above 400MHz, High side below 400MHz.

CTRA ENGINEERING PTY LTD Web page: www.spectraeng.com.au e-Mail: info@spectraeng.com.au

li *.......

i;q...

M a

0 B

A E.......S A T O R E I F C A ~

N ~,

n!.

]'

I

..*l

.'r h

III,,,,,0 Nl,,,,l

:"l!]i:i 4

ll;iii:l~l

'*L ii!

I h']1I],3:

?ul i

',;:,l],

i 4*,lh*:

I i

  • : !:]::] !? *! -

. ;*' :','*l:"':i*'*~l:*

r*q :......

'i*i

..4

!*:::' i:" *:11P

'1":'::.......

ý:

  • N:

ANCILLARIES Tx Timer:

VF Level to Line:

VF Level from Line:

De / Pre-Emphasis Accuracy:

VF Compressor Range:

Control Outputs:

Alarm Output:

PTT Input:

Channel Select:

Repeater Tail Timer:

Audio Output:

Audio Input:

Programmable, on/off selectable.

+6 to -15dBm, 600 ohms unbalanced or differential.

+6 to -I 5dBm, 600 ohms unbalanced.

Within +/-IdB of 6dB per octave curve.

>30dB for line input.

I K ohm 5V source/sink available.

Open collector.

Logic CMOS/TTL compatible.

8 way Dip switch or RS232 or BCD/ Binary.

Programmable.

IWatt for speaker, -1OdBm standard for line.

-1OdBm standard from line.

Due to ongoing development we reserve the right to alter specifications without notice.

SPECTRA ENGINEERING PTY LTD 9 Trade Road, Malaga 6090 Western Australia Telephone: +61-8-92482755 Web page: www.spectraeng.com.au Facsimile:

+61-8-92482756 e-Mail: info@spectraeng.com.au Rev 10.0 August 2006

3

.EER BAESATO ANE i

A

  • I E LE C

R

ýA S*

E IFC TI

,-S 1...

645441SBC w

Model Number Contact Factory 64544/SBC Contact Factory 65544/SBB (623) 581-2875 (623) 581-2876 Frequency Band (MHz) 118-138 144-190 190-300 375-440 Input Power 150W 150 W Spacing Min Space 5.0 MHz 5.0 MHz vs Loss Max Loss 1.5 dB 1.5 dB Isolation @ min Spacing 55+ dB 66+ dB Cavities Size City.

4" / 4 4" 14 List Price

$1,455.00

$1,440.00 MECoHANi,6ALSP -ýCI FI'C*ATI'ONS L Dim (HxWxD) (Max.)

Inches 32 1/2 x 19 x4 1/2 19 x 19 x 41/2 Metric 826 x483 x 115 483 x483 x 115 Connectors N Female N Female Finish EMR Gray EMR Gray Ship Weight: lbs.

33 19 kg.

15.0 8.4 65544/SBB I,f Dimensions are based on mounted position in a standard relay rack.

64544/SBC 65544/SBB

-- tR

2.

2-2 500...

  • H EMR Corp. 22402 N. 19th Avenue Phoenix, Arizona 85027 Toll Free:1-800-796-2875 Te1:'(623) 581-2875 Fax: (623) 582-9499 www.emrcorp.com e-mail: info@emrcorp.com 83

DULEER BAS STTO ANEN 65546/SBB C

655481SBB Model Number 65546/SBB 655481SBB 666410/SBB 656412/SBB Frequency Band (MHz) 375-440 376-440 376-440 375-440 Input Power 150 W 150 W 160 W 10 W Spacing Min Space 6.0 MHz 6.0 MHz 5.0 MHz 5.0 MHz vs Loss Max Loss 2.3 dB 2.7 dB 3.3 dB 4.0 dB Isolation @ min Spacing 70+ dB 70+ dB 75+ dB 76+ dB Cavities Size /Qty.

4" 1 6 4" / 8 4" / 10 4" / 12 List Price

$2,190.00

$2,865.00

$3,615.00

$4,375.00 Dim (HxWxD) (Max.)

Inches 8 314 x'19 x 19 8 3/4x 19 x 19 15 3/4x 19 x 19 15 3/4x 19 x 19 Metric 223 x 483 x 483 223 x 483 x 483 401 x 483 x 483 401 x 483 x 483 Connectors N Female N Female N Female N Female Finish EMR Gray EMR Gray EMR Gray EMR Gray Ship Weight: lbs.

33 42 50 55 kg.

15.0 19.1 22.7 26.0 Dimensions are based on mounted position in a standard relay rack 665410/SBB 65546/SBB 65548/SBB

)

000705 424 500 000 0145 SPAN 10.000 000 *44*

C0-,4r0 44.3. 4-000

-0 SPA I O. 05 0t00 0.

655412/SBB 655410/SBB 656412/SBB 10.8S ftr 0

tffl

,0 do, RE.

Os0 044 lea IlA 34*

L -20. 037.11 L...3.722t 4.

-- 21{0 0410 S

)

Pft C0 MA.H__

4

\\2 43 M

84 0007N4 484. 500 000 USA SPAS

1. 000 000 00 CANtER 24., 500 000 lE SPAN O. 000 P

00 D

EMR Corp. 22402 N. 19th Avenue Phoenix, Arizona 85027 Toll Free:l-800-796-2875 Tel: (623) 581-2875 Fax: (623) 582-9499 www.emrcorp.com e-mail: info@emrcorp.com

200 -

00M TWPC-2208-1, 2 BANDPASS CAVITIES TWPC-2208-1 TWPC-2208-2 The Telewave TWPC-2208-1 and 2208-2 are 8" diameter, 1/4-wave-length, high "Q" bandpass cavity filters with superior selectivity.

Bandpass cavities reject all fre-quencies outside a narrow pass band. These cavities reduce trans-mitter sideband noise, and also protect receivers against desensitization.

TWPC-2208 cavities cover 200-300 MHz. All cavities are tuned to specified frequencies prior to shipping, and no further adjust-ments should be required. The positive locking mechanism allows for quick field retuning if frequen-cy changes become necessary.

from 0.5 dB to 2 dB or more to improve selectivity. This allows cavity response to be optimized for any operating environment. At densely populated sites, the 2208-2 cavity filters provide greater se-lectivity with minimum insertion loss. Multiple cavities can also provide a wider passband when required. Mounting rails are pro-vided for all multiple-cavity filters.

Excellent frequency stability is achieved by the use of a special-ly machined compensator and Invar rod. The pass frequency is temperature stable from -30'C to +70'C. Telewave Ground Loop technology places the center con-ductor of each coupling loop at DC ground potential for lightning protection and noise reduction.

Heavy duty materials are used throughout each cavity to insure high performance and long life.

Cavity top plates are machined from 1/4-inch aluminum, and are heliarc welded to the cavity body at the high current point for im-proved conductivity and strength.

This allows Telewave cavities to handle up to 350 watts, depend-ing on insertion loss.

Rigid foam inserts support the tuner assembly allowing vertical or horizontal mounting. Similar metals and alodined aluminum help prevent galvanic corrosion.

Silver plated tuners and beryllium copper finger stock provide non-corrosive low loss contact, and ensure reliable, long-term performance.

These cavities also feature cali-brated adjustable coupling, and insertion loss can be easily set TEL EWA VE, INC.

660 Giguere Court, San Jose CA 1-800-331-3396 - 408-929-4400 www.telewave.com All specifications subject to change without notice TWDS-5015 Rev. 12/06

200 -

00M TWPC-2208-1, 2 TYPICAL SELECTIVITY CHARACTERISTICS Figure 2

-3

-2

-1 Fc

+1

+2

+3 Frequency (MHz) 0.15 to 2.0 dB 0.5 to 4.0 dB Maximum dimensions with tuners extended in. (cm) 8 x 22 (25 x 56) 8 x 19 x 22(25 x 48 x 56) 9(4.1) 19(8.6) 200-300 MHz I'

1.5:1

-30 0C to +70 0C 6061-T6 aluminum Tuning rod Invar Cavity dimensions (Diam. x H) in. (cm) 8 x 18 (20 x 46)

Finish Gray acrylic enamel NOTE: When ordering be sure to specify exact frequency and model number.

Contact the factory if additional information or assistance is required.

SEWAVE 660 Giguere Court, San Jose CA INC.

1-800-331-3396 e

408-929-4400 T

www.telewave.com All specifications subject to change without notice TWDS-5015 Rev. 12/06

A AirLink COM M UN I CAT IONS Raven CDMA/lx User Guide AirLink Communications, Inc.

version 2.23 May 2006

APPENDIX I Specifications for the Raven CDMA Physical Characteristics:

" Weight: < 1 lb.

" Size: 3"x 1.1"x 5.1"

" RF Antenna Connector: 50 Ohm TNC

" Serial Interface: RS232 DB-9F with 1200-115200 bps

" Status LEDs Data Services & RF Features: CDMA

" Full duplex transceiver

" Dual-band support for both 800 MHz cellular and 1.9 GHz PCS bands

" Dual band Receive Diversity

" Adheres to CDMA authentication as specified in CDMA2000 IX

" 224 mW RF output (+23.5 dBmn)

" Data rates up to 153.6 kbps (forward channel) and 76.8 kbps (reverse channel)

Environmental:

  • Operating ranges: -30'C to +70'C Raven (.DM/A User Guide f0r Verizon, version 2.23 jbr ferizn, vrsi 2.)

48

  • Humidity: 5%-95% Non-condensing Power Management:

" Low power consumption

  • Dormant connection (idle for 10-20 seconds): at 12 VDC

" Input Voltage: 10 VDC to 28 VDC

" Input Current: 20 mA to 350 mA

  • Low power mode: at 12 VDC Power consumption Serial Port Pin-outs The cable between the modem and a computer or other serial device needs to be wired straight-through (pin I goes to pin I, pin 2 to pin 2, etc).

Unti,.d t

eS a r To gpetA)

WI'S iRfqt"4-pt To~ SOWu) mi)f ma tta &44, ltouy)

GND (Ground)

F11" (031ai Terminal t nacy}

Tix (Tranmanfi) lRX [l.eo:.ivo)

D(CID (Data (,ýarrier Doipm)

Raven CDMA User Guide for Verizon, veiryion 2.23 49

"When Communication Is Critical You Can't Afford Interference" Features

" Eliminates Adjacent Channel Interference

" Entire Receiver Front End Solution: Includes Pre-Amplifier, and Channel Selection Filtering

" Fixed Frequency Filter, No Tuning Required

" Factory Set Gain From 0 to 10 dB

" Very Low Noise Figure

" Available Bandwidths: 6.25 kHz, 12.5 kHz, or 25 kHz

  • 4-Pole or 8-Pole Filter Response from 10 - 250 MHz
  • DC: Into Side Terminal or External Bias Tee on Output Description The UNI-Q is an active bandpass filter designed to solve interference problems by eliminating unwanted signals before they get to the receiver. The UNI-Q is factory tuned to pass your specific receive frequency at the gain you choose. A channel that was once plagued by interference and rendered useless can be made useful again with the UNI-Q filter. With wireless technology becoming more widely used, the issue of receiver interference is getting worse. Giving up a channel isn't feasible, especially with today's demands to keep the lines of communication open. Typical applications include Police, Fire, EMS, SCADA, and commercial two-way radio systems.

Electrical Specifications Parameter' Frequency Min.

Typ.

Max.

Units Gain (Customer Specified) 10 - 250 MHz 0

10 dB Noise Figure 10 - 250 MHz 1.0 1.2 dB Intermodulation Products2 10 - 250 MHz

-100 dBm Input Power for I dB Compression 10 - 250 MHz

-2 0

dBm VSWR (I/O) 10 - 250 MHz 1.4:1 1.5:1 6.25 kHz Bandwidth Availability 10 - 150 MHz 12.5 kHz Bandwidth Availability 10 - 200 MHz 25 kHz Bandwidth Availability 10 - 250 MHz Bandwidth Tolerance

-/+ 5 %

Channel Ripple I dB max Channel Configuration I Simplex Channel I/O Impedance 50 Q 1/0 Connectors Type N Female (Other Connectors Available Upon Request)

Power Requirement 70 mA @ 12V DC Stand-Alone (I 15V AC, 9 - 36V DC, or 18 -75V DC in 19" Rack)

Weight

< 1 lb Stand-Alone

(< 5 lbs in 1U 19" Rack Mount Chassis)

Size 2.4" x 4.4" x 1.3" Stand-Alone. (1U 19" Rack Mount Chassis 19" x 8" x 1.75")

I. All measurements made in a 50 n system

2. Intermodulation product tone spacing = 500 kHz, Pin per tone = -40 dBm BARTLEY MACHINE & MFG. CO. INC.

35 Water St:L.

Amesbury, MA 01913 978 388.0085

  • Fax: 978.388.9i61, Email: sales@ulhraqrfiher.com
  • www.ultraqfilter.com Rev II

JUl QM Adtiw FM*es EEd CtrI FOW Performance Data The red trace shows 50 kHz of VHF spectrum measured at a receiver site in a heavily populated metropolitan area. The blue trace shows the same spectrum measured after installation of the UNI-Q filter. The desired signal is amplified while interference is eliminated. The lines of communication are kept clear.

-30

-40

.50 d8.,

-70

-40 490 140o 15797500 15798125 15798750 15799875 158000000 15800625 15801250 15801875 15802500 Frequn...y (MHO)

Filter Response Data -

Normalized to 0 dB Gain 8-Pole.25 kHz Bandwidth CL 0.

a 10 0

-10

-20

-30

-40

-50

-60

-70

-80 o

,0 a

0 10 aF 0

a eny 0

t0 k 0

o 40 1-i 0

0 Ný N-o 0

4 4

Frequency Offset (kHz)

Absolute Maximum Ratings Characteristic Value RF Input Power

-15 dBm - Gain Operating Temperature

-20'C to +60'C Storage Temperature

-40'C to +85°C Note: Exceeding these parameters may cause permanent damage.

BARTLEY MACHINE & MFG. CO. INC.

  • 35 Water St.
  • Amesbury, MA 01913 978.388.0085
  • Fax: 978.388.9161
  • Email: sales@ultraqfilter.com
  • www.ultraqfilter.com Rev 1.1 2

AUDIO] PTT DISTRIBUTION PANEL 2241A FRONT VIEW CD ED e

CONVEX2241A AUDIO/ PTT DISTRIBUTION PANEL 1

2 3

4 5

6 7

8 9

10 1

12 13 4

15 16 17 18 19 20 21 22 23 24 M-_00 00 00@

0 00 0 0

e Q

0 (Do 00 0 00 00 e 0 e 0 0 0 --ER REAR VIEW LONV]WX 2241A AUDIO I PTT DISTRIBUTION PANEL MADE IN USA 90-26 VAC MAIN SACKUP OUTPUT-PTT INPUT OUTPUT-AUDIO -

INPUT 01 00 b,

o0 0

c 00, 0

2 11AMP 2241A AUDIO / PTT DISTRIBUTION PANEL The 2241A Panel provides a compact means of distributing audio and Push to Talk (PTT) signals to as many as 24 base stations. In addition, it provides manual PTT override for individual transmitters. 24, lighted, front panel switches permit each radio to be keyed, disabled, or track normal console control. Manual PTT control is used for installation and management of radio networks.

It is also used to align simulcast networks by enabling one transmitter at a time to measure delay.

PTT BUFFERING High current PTT Outputs permit direct drive of equipment requiring up to 100 mA keying current. The Panel accepts 12 or 24 low current PTT inputs and provides high current outputs.

PTT LOGIC CONVERSION Independent PTT Input and Output Logic Selectors permit PTT logic conversion among: ElM, TTL, and *Digitac.

SPECIFICATIONS AUDIO DISTRIBUTION AMPS Frequency Range:

20 Hz ti Tx Inputs:

8 Floati Sum Inputs 8 Floati Outputs:

24 Floa Gain:

0 dB, +,

I/O Return Loss:

Greater Input/Output Level:

+10 dBi Noise:

Less th; PTT CIRCUITS Outputs:

24 High Current E/M, TTL, or *D Inputs:

24 E/M Type 1-o 5000 Hz ng, Balanced, 600 Ohm ng, Balanced, 600 / Hi Z ting, Balanced, 600 Ohm

/- 10 dB /24 FP controls than 26 dB m maximum an -60 dBmC t(100 mA) Outputs igitac / Relay Closure 5, TTL, or *Digitac The 2241A is packaged in a 1U high, rack mounting, panel. Power options include a universal AC Supply; or 12, 24, or 48 Volt DC Supplies. Redundant power modules can be replaced while the panel is in service.

Front panel LEDs indicate the status of each power module. A contact closure is provided across pins 25/50 on the Audio Output Connector to alarm in the event of a power module failure.

Audio and PTT distribution is configured by 7 internal switches which can be set to fan out a single input to up to 24 outputs, 2 inputs to 12 outputs, or various other configurations.

Distribution Capacity: 24 Audio Outputs per 2241A 8 Audio Inputs per 2241A 8 Summing Inputs per 2241A 24 PTT Outputs per 2241A 8 PTT Inputs can be distributed 24 PTT Inputs for buffering, or logic conversion 8 Inputs for distribution applications M Type 1,11,111: Key <-20 V / Idle >-20 V M Type IV, V; E: Key >-20 / Idle <-20 V TTL: Key < +2.5 V / Idle > +2.5 V

  • Digitac: Key < +6 V / Idle > +6 V
  • Digitac is a Trademark of Motorola Inc.

AUDIO / PTT DISTRIBUTION CONTROL 7 Switches:

1 Input to 24 Outputs, or 2 Inputs to 12 Outputs each, or numerous other distribution options.

MANUAL PTT CONTROL PTT Switches 24 (3 Position) Front Panel Switches KEY:

Keys transmitter / Lit Red NORMAL Console control / Lit Green = PTT DISABLE Disables PTT / Lit Red ENVIRONMENT:

-30 to 600 C, 95% R.H.

1/0 CONNECTORS:

2 sets of 50 pin "Telco" type DIMENSIONS:

1.7" H x 10" D x 19" W. / 6 lbs.

POWER 90-264 VAC; Order: 2241A-AC 12, 24, or 48 VDC, Order: 2241A-XX WARRANTY All Convex Products are warranted to be free of manufacturing defects for a period of one year.

(c) Convex Corporation 2004

Convex Corporation - 1319 Shepard Drive - Sterling, VA 20164 USA 703-433-9901 - fax 703-433-9904 - www.ConvexCorp.com

APPENDIX G SUPPORTING DOCUMENTATION/REFERENCES Code of Federal Regulations, Title 44, Chapter I, Part 350, "Review and Approval of State and Local Radiological Emergency Plans and Preparedness", Planning Standard E NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency response Plans and Preparedness in Support of Nuclear Power Plants", U.S. Nuclear Regulatory Commission/ Federal Emergency Management Agency, November 1980 FEMA-REP-1 0, "Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants", Federal Emergency Management Agency, November 1985 Energy Policy Act of 2005, Public Law 109-58, section 651 (b), "Backup Power for Certain Emergency Notification Systems." August 8, 2005 CPG 1-17, "Outdoor Warning Systems Guide", Federal Emergency Management Agency, March 1, 1980 American National Standards Institute (ANSI) S12.14-1992, "Methods for the Fixed Measurement of the Sound Output of Audible Public Warning Devices Installed at Fixed Locations Outdoors" International Organization for Standardization ISO 9613-2:1996, International Standard, "Acoustics - Attenuation of Sound During Propagation Outdoors" American National Standards Institute (ANSI) S1 2.18-1994, "Procedures for Outdoor Measurements of Sound Pressure Level" Entergy Nuclear Northeast "Report on Trees and Tree Trimming at the Indian Point Energy Center (IPEC) Alert Notification Siren Sites, September 24, 2007 to November 17, 2007," Volume I - Putnam and Westchester Counties, November 30, 2007 Entergy Nuclear Northeast "Report on Trees and Tree Trimming at the Indian Point Energy Center (IPEC) Alert Notification Siren Sites, September 24, 2007 to November 17, 2007," Volume II - Orange and Rockland Counties, November 30, 2007 "Acoustic Testing of Prompt Alert Notification System Sirens from Indian Point Energy Center", Volume I Chamber Testing, Georgia Tech Research Institute GTRI Report D5600-Volume I, Wyle Laboratories Report WR-07-25, Volume I, dated 3/08 "Acoustic Testing of Prompt Alert Notification System Sirens from Indian Point Energy Center", Volume II Outdoor Siren Testing, Georgia Tech Research Institute GTRI Report D5600-Volume II, Wyle Laboratories Report WR-07-25, Volume II, dated 3/08 G-1

"Acoustic Testing of Prompt Alert Notification System Sirens from Indian Point Energy Center", Volume III New Omni-Directional Siren Output Validation, Georgia Tech Research Institute GTRI Report D5600-Volume III, Wyle Laboratories Report WR-07-25, Volume III, dated 3/08 "General Acoustical Analysis of the New Indian Point Siren System - Final Report",

August 2007, Blue Ridge Research and Consulting Entergy Nuclear Failure Modes and Effects Analysis (FMEA) of the New Siren System for Indian Point Energy Center, IP-RPT-08-00005, April 2008 MIL-STD-1 629, "Procedures for Performing a Failure Mode, Effects and Criticality Analysis", Military Standards and Specifications, November 24, 1980 MIL-STD 882, "Safety System Program Requirements", Military Standards and Specifications, July 15, 1969 MIL-HDBK-217F, "Reliability Prediction of Electronic Equipment', US Department of Defense, December 2, 1991 G-2

APPENDIX H APPENIX H CONTROL SYSTEM RELIABILITY TESTING RESULTS H-1

Table H-2 IPEC ANS DIAGNOSTIC TESTING ACTIVATION ACTIVATION

  1. OF SIRENS # OF SIRENS # OF SIRENS TYPE LOCATION TESTED PASSED FAILED Wednesday, August 01, 2007 9:45 AM SINGLE EOF 205 1

1 0

Wednesday, August 01, 2007 10:08 AM SINGLE EOF 353 1

1 0

Wednesday, August 01, 2007 10:41 AM SINGLE EOF 221 1

0 1

Wednesday, August 01, 2007 11:44 AM SINGLE EOF 233 1

1 0

Wednesday, August 01, 2007 12:55 PM SINGLE EOF 236 1

1 0

Wednesday, August 01, 2007 1:02 PM SINGLE EOF 302 1

0 1

Wednesday, August 01, 2007 1:08 PM SINGLE EOF 316 1

1 0

Wednesday, August 01, 2007 2:53 PM GROUP EOC ALL 150 149 1

Wednesday, August 01, 2007 3:49 PM SINGLE EOF 302 1

1 0

Thursday, August 02, 2007 11:04 AM SINGLE EOF 405 1

1 0

Thursday, August 02, 2007 2:43 PM SINGLE EOF 406 1

1 0

Thursday, August 02; 2007 6:05 PM GROUP EOF ALL 150 149 1

Thursday, August 02, 2007 6:31 PM GROUP EOF ALL 150 141 9

Thursday, August 02, 2007 6:46 PM GROUP EOF ALL 150 150 0

Thursday, August 02, 2007 7:27 PM GROUP EOF ALL 150 150 0

Thursday, August 02, 2007 7:45 PM SINGLE EOF 325 1

1 0

Friday, August 03, 2007 3:19 PM SINGLE EOF 221 1

1 0

Monday, August 06, 2007 8:00 PM GROUP EOF ALL 155 152 3

Monday, August 06, 2007 8:27 PM GROUP MOBILE CCU ALL 155 154 1

Tuesday, August 07, 2007 7:40 AM GROUP MOBILE CCU ALL 0

0 0

Tuesday, August 07, 2007 7:42 AM GROUP MOBILE CCU ALL 155 155 0

Tuesday, August 07, 2007 8:06 AM GROUP MOBILE CCU ALL 155 154 1

Tuesday, August 07, 2007 8:36 AM GROUP EOF ALL 155 154 1

Tuesday, August 07, 2007 9:07 AM SINGLE EOF 107 1

1 0

Tuesday, August 07, 2007 9:27 AM SINGLE EOF 371 1

1 0

Tuesday, August 07, 2007 9:34 AM GROUP MOBILE CCU ALL 155 152 3

Tuesday, August 07, 2007 10:07 AM SINGLE GSB 371 1

1 0

Tuesday, August 07, 2007 10:13 AM SINGLE EOF 247 1

1 0

Tuesday, August 07, 2007 10:29 AM SINGLE EOF 371 1

0 1

Tuesday, August 07, 2007 10:37 AM SINGLE GSB 246 1

1 0

Tuesday, August 07, 2007 11:00 AM SINGLE EOF 246 1

1 0

Tuesday, August 07, 2007 11:11 AM SINGLE GSB 370 1

0 1

Tuesday, August 07, 2007 11:40 AM GROUP GSB ALL 155 152 3

Tuesday, August 07, 2007 11:43 AM GROUP MOBILE CCU ALL 155 155 0

Tuesday, August 07, 2007 12:22 PM GROUP MOBILE CCU ALL 155 155 0

Tuesday, August 07, 2007 1:45 PM SINGLE EOF 371 11 1

0 Wednesday, August 08, 2007 8:02 AM GROUP EOF ALL 155 155 0

Wednesday, August 08, 2007 10:07 AM SINGLE EOF 370 1

1 0

Wednesday, August 08, 2007 3:49 PM SINGLE EOF 325 1

1 0

Wednesday, August 08, 2007 3:54 PM SINGLE EOF 248 1

1 0

Wednesday, August 08, 2007 4:00 PM GROUP MOBILE CCU ALL 155 154 1

Wednesday, August 08, 2007 4:23 PM SINGLE EOF 308 1

1 0

Wednesday, August 08, 2007 5:35 PM SINGLE EOF 102 1

0 1

Wednesday, August 08, 2007 6:23 PM GROUP NEM ALL 155 155 0

Thursday, August 09, 2007 9:38 AM GROUP EOF ALL 155 0

155 Thursday, August 09, 2007 10:12 AM SINGLE EOF 331 1

1 0

Thursday, August 09, 2007 10:15 AM SINGLE EOF 320 1

1 0

Thursday, August 09, 2007 10:22 AM SINGLE EOF 318 1

1 0

Thursday, August 09, 2007 10:31 AM SINGLE EOF 322 1

1 0

Thursday, August 09, 2007 10:33 AM SINGLE GSB 365 1

0 1

Thursday, August 09, 2007 10:38 AM SINGLE EOF 344 1

0 1

Thursday, August 09, 2007 11:13 AM GROUP EOF ALL 155 105 50 Thursday, August 09, 2007 1:18 PM GROUP EOF ALL 155 109 46 Thursday, August 09, 2007 1:54 PM GROUP EOF ALL 155 154 1

Thursday, August 09, 2007 2:51 PM SINGLE EOF 115 1

1 0

Thursday, August 09, 2007 2:51 PM SINGLE EOF 212 1

1 0

Thursday,. August 09, 2007 2:51 PM SINGLE EOF 218 1

1 0

Thursday, August 09, 2007 2:51 PM SINGLE EOF 1

301 1

11 0

Thursday, August 09, 2007 2:51 PM SINGLE EOF 306 11 1

0 8122/2007 10:14 AM

,H-3

Table H-2 (Cont'd)

IPEC ANS DIAGNOSTIC TESTING ACTIVATION ACTIVATION

  1. OF SIRENS # OF SIRENS # OF SIRENS TYPE LOCATION SIREN TESTED PASSED FAILED Thursday, August 09, 2007 2:51 PM SINGLE EOF 343 1

1 0

Thursday, August 09, 2007 3:21 PM SINGLE EOF 232 1

1 0

Thursday, August 09, 2007 3:21 PM SINGLE EOF 304 1

1 0

Thursday, August 09, 2007 3:21 PM SINGLE EOF 319 1

1 0

Thursday, August 09, 2007 3:38 PM SINGLE EOF 229 1

1 0

Thursday, August 09, 2007 3:44 PM SINGLE EOF 369 1

1 0

Thursday, August 09, 2007 3:44 PM SINGLE EOF 371 1

1 0

Thursday, August 09, 2007 4:02 PM SINGLE GSB 353 1

0 1

Thursday, August 09, 2007 4:04 PM SINGLE GSB 353 1

0 1

Thursday, August 09, 2007 4:14 PM SINGLE EOF 227 1

1 0

Thursday, August 09, 2007 4:26 PM GROUP EOF ALL 155 154 1

Thursday, August 09, 2007 5:52 PM GROUP EOF ALL 155 151 4

Thursday, August 09, 2007 6:22 PM GROUP EOF ALL 155 152 3

Thursday, August 09, 2007 6:39 PM SINGLE EOF 307 1

1 0

Thursday, August 09, 2007 6:41 PM SINGLE EOF 119 1

1

,0 Thursday, August 09, 2007 6:43 PM SINGLE EOF 235 1

1 0

Thursday, August 09, 2007 6:48 PM GROUP EOF ALL 155 153 2

Thursday, August 09, 2007 7:08 PM GROUP EOF ALL 155 153 2

Thursday, August 09, 2007 7:27 PM GROUP EOF ALL 155 155 0

Thursday, August 09, 2007 7:38 PM GROUP EOF ALL 155 155 0

Friday, August 10, 2007 1:07 PM SINGLE EOF 353 1

1 0

Saturday, August 11, 2007 12:20 PM SINGLE EOF 120 1

1 0

Saturday, August 11, 2007 12:25 PM SINGLE EOF 321 1

1.

0 Saturday, August 11, 2007 1:48 PM SINGLE EOF 102 1

1 0

Saturday, August 11, 2007 3:14 PM SINGLE EOF 233 1

1 0

Sunday, August 12, 2007 10:58 AM SINGLE EOF 345 1

1 0

Sunday, August 12, 2007 11:56 AM SINGLE EOF 321 1

1

.0 Sunday, August 12, 2007 1:42 PM SINGLE EOF 362 1

1 0

Sunday, August 12, 2007 3:05 PM SINGLE EOF 355 1

1 10 Sunday, August 12, 2007 6:48 PM SINGLE EOF 120 1

1 10 Monday, August 13, 2007 2:18 PM SINGLE EOF 218 1

1 0

TOTALS 4376 4079 297

% RELIABILITY: 93.21%

H-4 8/22/2007 10:14 AM

Table H-3. Activation Locations for Testing Performed September 6-17, 2007 TEST Westchester Putnam Orange Rockland 1

WP WP WP EOC 2

WP WP WP.

EOC 3

WP EOC EOC WP 4

WP EOC EOC WP 5

WP WP WP WP

.6 WP WP WP WP 7

WP EOC EOC EOC 8

WP EOC EOC EOC 9

EOC EOC WP WP 10 EOC EOC WP WP 11 EOC WP EOC EOC 12 EOC WP EOC EOC 13 EOC WP EOC EOC 14 EOC WP EOC EOC 15 EOC EOC WP WP 16 EOC EOC WP WP 17 Both tests performed by activating sirens in all 18 four counties from the Rockland EOC 19 Both tests performed by activating sirens in all 20 four counties from the Rockland WP I W

, I I II

  • Four tests conducted on each of 5 days (September 6, 7, 10, 11, and 17) for a total of 20 tests a Test Method: Tests 1 through 16: Microwave Tests 17 through 20: TCP/IP o Activation Location: See following Table H-5

Table H-4. Control System Test Results for Testing Performed September 6 - 17, 2007 Westchester Putnam rag Rockland All Counties TEST Fail %

Fail

% Success Fail

% Success Fail %/ Success Fail

___Success Success 1

0 100%

0 100%

1 95.4%

0 100%

1 99.3%

2 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

3 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

4 10 100%

0 100%

1 95.4%

6 87.5%

7 95.4%

5 10 100%

0 1100%

1 95.4%

0 100%

1 99.3%

6 10 100%

0 100%

1 95.4%

1 97.9%

2 98.7%

7 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

8 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

9 0

100%

0 100%

2 90.9%

0 100%

2 98.7%

10 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

11 10 100%

0 100%

1 95.4%

0 100%

1 99.3%

12 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

13 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

14 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

15 0

100%

0 100%

1 95.4%

0 100%

1 99.3%

16 10 100%

0 100%

1 95.4%

0 100%

1 -99.3%

17 1

98.5 0

100%

1 95.4%

0 100%

2 98.7%

18 1

98.5 0

100%

1 95.4%

0 100%

2 98.7%

19 1

98.5 0

100%

2 90.9 0

100%

3 98.0%

20 1

98.5 0

100%

2 90.9 0

100%

13 98.0%

Total success rate: 98.9%

Activation Results:

All 20 tests involved activation of all 155 installed sirens (Westchester: 71, Putnam: 14, Orange: 22, and Rockland 48) e Evaluation of Results Siren 122 in Orange County had been placed in a maintenance mode. It was a siren that was in the process of being converted from solar-battery power to A/C - battery power and was unavailable for testing. It was recorded as a failure for the purposes of these tests.

In one test on September 6, 2007, six failures were recorded in Rockland County. IPEC consulted with SAIC and determined that the most likely cause of this condition was sporadic radio interference due the close proximity and orientation of several antennas on the roof the Rockland County emergency services building in Pomona, NY. Entergy subsequently confirmed that the transmitter causing the interference had been retired and removed by the county. It was determined that there no longer was 200 MHz interference at this site.

H-6

APPENDIX I SIMULCAST RADIO SYSTEM (SCHEMATIC DIAGRAM)

I-1

APPENDIX J LOCATIONS OF SIRENS, CONTROL STATIONS, AND REPEATERS (MAP)

J-1

APPENDIX K SIREN COVERAGE WITHIN THE EPZ OF INDIAN POINT ENERGY CENTER (MAP)

K-I