May 12, 2008 Mr. William Bonzer, Reactor Manager Missouri University of Science and Technology 226 Fulton Hall Rolla, MO 65409-0170
SUBJECT:
MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY RESEARCH REACTOR (MSTR) FACILITY B REQUEST FOR ADDITIONAL INFORMATION (RAIs) REGARDING LICENSE RENEWAL (TAC NO. MC5737)
Dear Mr. Bonzer:
We are continuing our review of your August 30, 2004 application, and your responses to RAI submissions dated November 16, November 27, December 26, 2007; January 17, and March 6, 2008, and associated supplements, for license renewal of the MSTR. After reviewing your submissions, questions have arisen for which we require additional information and clarification.
During a discussion with you on May 5, 2008, you agreed to provide a response to the enclosed Request for Additional Information (RAI) no later than June 16, 2008. Your timely response is needed to support completion of the review. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.
Should you have any questions, please contact me at 301-415-4007.
Sincerely,
/RA/
John Nguyen, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123 License No. R-79
Enclosures:
As stated cc w/enclosure: See next page
May 12, 2008 Mr. William Bonzer, Reactor Manager Missouri University of Science and Technology 226 Fulton Hall Rolla, MO 65409-0170
SUBJECT:
MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY RESEARCH REACTOR (MSTR) FACILITY B REQUEST FOR ADDITIONAL INFORMATION (RAIs) REGARDING LICENSE RENEWAL (TAC NO. MC5737)
Dear Mr. Bonzer:
We are continuing our review of your August 30, 2004 application, and your responses to RAI submissions dated November 16, November 27, December 26, 2007; January 17, and March 6, 2008, and associated supplements, for license renewal of the MSTR. After reviewing your submissions, questions have arisen for which we require additional information and clarification.
During a discussion with you on May 5, 2008, you agreed to provide a response to the enclosed Request for Additional Information (RAI) no later than June 16, 2008. Your timely response is needed to support completion of the review. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.
Should you have any questions, please contact me at 301-415-4007.
Sincerely,
/RA/
John Nguyen, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123 License No. R-79
Enclosures:
As stated cc w/enclosure: See next page DISTRIBUTION:
PUBLIC RidsNrrDprPrta RidsNrrDprPrtb RTR R/F ACCESSION NO.: ML081270024 Template No.: NRR-106 OFFICE PRTA:PM PRTA:LA DRIP/RPRP:
PRTA:BC NAME J Nguyen jtn EBarnhill eeb CPittigilo cp DCollins dsc DATE 5/12/08 5/12/08 5/12/08 5/12/08
Missouri University of Science and Technology Docket No. 50-123 cc:
Dr. Samuel Frimpong, Chair School of Mines and Nuclear Engineering 305 McNutt Hall Missouri University of Science and Technology Rolla, MO 65409-0630 Dan Estel Missouri University of Science and Technology Nuclear Reactor Facility 1870 Miner Circle Rolla, MO 65409-0630 Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809 State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
REQUEST FOR ADDITIONAL INFORMATION MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY DOCKET NO. 50 -123
- 1. Section 13.1.1. This Section, Maximum Hypothetical Accident (MHA) - Failure of a Fueled Experiment, states, The resulting whole-body dose associated with the 100 watt fueled experiment was 242 mrem; the whole-body dose was lower by about two magnitudes for the 1 W case. This dose is a factor of two lower than the 10 CFR Part 20 annual limit of 500 mrem exposure to individuals in unrestricted areas.
Provide the specific section of 10 CFR Part 20 in the above reference statement (i.e., the 10 CFR Part 20 annual limit of 500 mrem exposure to individuals in unrestricted areas). If 10 CFR Part 20.1301(d) is used in the above reference statement, please (i) provide demonstration of the need for, the frequency, and the expected duration of operations in the 100 watt fuel experiment; (ii) provide the licensees program to assess and control dose within the 500 mrem annual limit; and (iii) the procedure to be followed to maintain the dose as low as is reasonably achievable (ALARA).
Provide the MHA dose associated with the 1 watt fuel experiment. If the dose received by individuals in unrestricted areas does exceed 100 mrem, provide justification in the above paragraphs (i) and (ii).
Alternatively, demonstrate that the TEDE to individual members of the public from licensed operation does not exceed 100 mrem in a year per 10 CFR Part 20.1301(a)(1) for both the 100 W and 1 W fueled experiment. Provide the analysis, or limiting conditions of fuel experiment to ensure that the proposed MHA dose does not exceed 100 mrem to individual members of the public. Also, provide justification why the current analysis differs from the previous one.
- 2. In accordance with 10 CFR Part 50.33(f), the staffs analysis to determine whether the applicant is financially qualified to operate the reactor facility will include a review of the applicants latest financial statements. Since this information is not included in the application, please provide a copy of the latest financial statements of the Missouri University of Science and Technology.
- 3. The application, dated August 30, 2004, states that the 1990 cost estimate to decommission the reactor has been updated annually by using the methodology described in NUREG-1307, which referenced a 1990 decommissioning cost of $0.816 million and an updated estimate cost of $1.925 million in 2005 dollars. In accordance with 10 CFR 50.75(d) and 50.33(k),
please update the application to include the following:
a) Provide a current cost estimate for decommissioning the MST reactor (in 2008 dollars);
b) Indicate which method or methods described in paragraph (e) of 10 CFR Part 50.75 as acceptable to the NRC will be used to provide funds for decommissioning; and c) Provide a description of the means of adjusting the future cost estimate and associated funding level that will be used over the life of the facility.
Enclosure