April 23, 2008 Mr. Randy C. Bunt, Chair BWR Owners= Group Southern Nuclear Operating Company 40 Inverness Center Parkway/Bin B057 Birmingham, AL 35242
SUBJECT:
ACCEPTANCE FOR REVIEW OF BOILING WATER REACTORS OWNERS=
GROUP (BWROG) TOPICAL REPORT (TR) NEDC-33347P, REVISION 0, CONTAINMENT OVERPRESSURE CREDIT FOR NET POSITIVE SUCTION HEAD" (TAC NO. MD8146)
Dear Mr. Bunt:
By letter dated February 15, 2008, the BWROG submitted for U.S. Nuclear Regulatory Commission (NRC) staff review TR NEDC-33347P, Revision 0, Containment Overpressure Credit For Net Positive Suction Head." The NRC staff has performed an acceptance review of the NEDC-33347P. We have found that the material presented is sufficient to begin our comprehensive review. The NRC staff expects to issue its request for additional information by November 7, 2008, and issue its draft safety evaluation by June 12, 2009. The NRC staff estimates that the review will require approximately 450 staff hours including project management time. The review schedule milestones and estimated review costs were discussed and agreed upon in a telephone conference between Frederick Emerson, Project Manager, and the NRC staff on April 22, 2008.
In accordance with the letter dated December 4, 2007 (Agencywide Documents Access and Management System Accession No. ML073410162), the fee branch has waived the Section 170.21 of Title 10 of the Code of Federal Regulations fees associated with this TR review.
If you have any questions regarding this matter, please contact Michelle C. Honcharik on (301) 415-1774.
Sincerely, Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No. 691 cc: See next page
April 23, 2008 Mr. Randy C. Bunt, Chair BWR Owners= Group Southern Nuclear Operating Company 40 Inverness Center Parkway/Bin B057 Birmingham, AL 35242
SUBJECT:
ACCEPTANCE FOR REVIEW OF BOILING WATER REACTORS OWNERS=
GROUP (BWROG) TOPICAL REPORT (TR) NEDC-33347P, REVISION 0, CONTAINMENT OVERPRESSURE CREDIT FOR NET POSITIVE SUCTION HEAD" (TAC NO. MD8146)
Dear Mr. Bunt:
By letter dated February 15, 2008, the BWROG submitted for U.S. Nuclear Regulatory Commission (NRC) staff review TR NEDC-33347P, Revision 0, Containment Overpressure Credit For Net Positive Suction Head." The NRC staff has performed an acceptance review of the NEDC-33347P. We have found that the material presented is sufficient to begin our comprehensive review. The NRC staff expects to issue its request for additional information by November 7, 2008, and issue its draft safety evaluation by June 12, 2009. The NRC staff estimates that the review will require approximately 450 staff hours including project management time. The review schedule milestones and estimated review costs were discussed and agreed upon in a telephone conference between Frederick Emerson, Project Manager, and the NRC staff on April 22, 2008.
In accordance with the letter dated December 4, 2007 (Agencywide Documents Access and Management System Accession No. ML073410162), the fee branch has waived the Section 170.21 of Title 10 of the Code of Federal Regulations fees associated with this TR review.
If you have any questions regarding this matter, please contact Michelle C. Honcharik on (301) 415-1774.
Sincerely,
/RA/
Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No. 691 cc: See next page DISTRIBUTION:
PUBLIC PSPB Reading File RidsNrrDpr RidsNrrDprPspb RidsNrrLADBaxley RidsAcrsAcnwMailCenter RidsNrrPMMHoncharik RidsOgcMailCenter RidsNrrDss RidsNrrDssScvb Ahsan Sallman Richard Lobel Robert Dennig SRosenberg (Hardcopy)
ADAMS ACCESSION NO.: ML081090399 NRR-106 OFFICE PSPB/PM PSPB/LA SCVB/BC PSPB/BC NAME MHoncharik DBaxley RDennig SRosenberg DATE 4/22/08 4/21/08 3/7/08 4/23/08 OFFICIAL RECORD COPY
BWR Owners= Group Project No. 691 Mr. Doug Coleman Vice Chair, BWR Owners= Group Energy Northwest Columbia Generating Station Mail Drop PE20 P.O. Box 968 Richland, WA 99352-0968 DWCOLEMAN@energy-northwest.com Mr. Richard Libra Executive Vice Chair, BWR Owners= Group Exelon Generation Co, LLC 200 Exelon Way Mail Code KSA 2-N Kennett Square, PA 19348 Rick.libra@exeloncorp.com Mr. Richard Anderson BWROG, Executive Chair FPL Energy (DAEC)
Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324 richard_l_anderson@fpl.com Mr. James F. Klapproth GE-Hitachi Nuclear Energy M/C A50 3901 Castle Hayne Road Wilmington, NC 28401 james.klapproth@ge.com Mr. Joseph E. Conen Regulatory Response Group Chair BWR Owners= Group DTE Energy-Fermi 2 200 TAC 6400 N. Dixie Highway Newport, MI 48166 conenj@dteenergy.com Mr. J. A. Gray, Jr.
Regulatory Response Group Vice-Chair BWR Owners= Group Entergy Nuclear Northeast 440 Hamilton Avenue Mail Stop 12C White Plains, NY 10601-5029 JGray4@entergy.com Mr. Ken A. McCall, Program Manager GE Energy M/C F12 3901 Castle Hayne Road Wilmington, NC 28401 kenneth.mccall@ge.com Mr. Tim E. Abney GE Energy M/C A-16 3901 Castle Hayne Road Wilmington, NC 28401 tim.abney@ge.com Oscar Limpias Entergy Nuclear Northeast 1340 Echelon Parkway.
Jackson, MS 39213-8202 olimpia@entergy.com Joe Donahue Progress Energy Inc.
410 S. Wilmington St.
PEB 6A Raleigh, NC 27601-1849 joe.w.donahue@pgnmail.com Paul J. Davison Hope Creek Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 paul.davison@pseg.com Dennis Madison, Hatch Vice President Southern Nuclear Operating Co.
11028 Hatch Parkway North Baxley, GA 31515-2010 drmadiso@southernco.com Frederick Emerson BWROG, Project Manager Frederick.emerson@ge.com 3/18/08