March 22, 2010 Mr. Frederick Schiffley BWROG, Chairman Exelon Generation Co., LLC.

Cornerstone II at Cantera 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

REVISED DRAFT SAFETY EVALUATION OF BOILING WATER REACTORS OWNERS= GROUP (BWROG) TOPICAL REPORT NEDC-33347, REVISION 0, "CONTAINMENT OVERPRESSURE CREDIT FOR NET POSITIVE SUCTION HEAD (NPSH)" (TAC NO. MD8146)

Dear Mr. Schiffley:

By letter dated February 15, 2008 (Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML080520268), the BWROG submitted topical report (TR)

NEDC-33347, Revision 0, "Containment Overpressure Credit for Net Positive Suction Head (NPSH)" to the U.S. Nuclear Regulatory Commission (NRC) staff.

By letter dated September 29, 2009, an NRC draft safety evaluation (SE) regarding our approval of TR NEDC-33347, Revision 0, was provided for your review and comment. By letter dated October 27, 2009, the BWROG commented on the draft SE. The NRC staff's disposition of the BWROGs comments on the draft SE are discussed in the attachment to the revised draft SE enclosed with this letter. A final SE will be issued after the Advisory Committee on Reactor Safeguards review.

If you have any questions, please contact Michelle C. Honcharik at 301-415-1774.

Sincerely,

/RA/

Stacey L. Rosenberg, Chief Licensing Processes Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No. 691

Enclosure:

Revised Draft SE cc w/o encl: See next page

Mr. Frederick Schiffley BWROG, Chairman Exelon Generation Co., LLC.

Cornerstone II at Cantera 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

REVISED DRAFT SAFETY EVALUATION OF BOILING WATER REACTORS OWNERS= GROUP (BWROG) TOPICAL REPORT NEDC-33347, REVISION 0, "CONTAINMENT OVERPRESSURE CREDIT FOR NET POSITIVE SUCTION HEAD (NPSH)" (TAC NO. MD8146)

Dear Mr. Schiffley:

By letter dated February 15, 2008 (Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML080520268), the BWROG submitted topical report (TR)

NEDC-33347, Revision 0, "Containment Overpressure Credit for Net Positive Suction Head (NPSH)" to the U.S. Nuclear Regulatory Commission (NRC) staff.

By letter dated September 29, 2009, an NRC draft safety evaluation (SE) regarding our approval of TR NEDC-33347, Revision 0, was provided for your review and comment. By letter dated October 27, 2009, the BWROG commented on the draft SE. The NRC staff's disposition of the BWROGs comments on the draft SE are discussed in the attachment to the revised draft SE enclosed with this letter. A final SE will be issued after the Advisory Committee on Reactor Safeguards review.

If you have any questions, please contact Michelle C. Honcharik at 301-415-1774.

Sincerely,

/RA/

Stacey L. Rosenberg, Chief Licensing Processes Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No. 691

Enclosure:

Revised Draft SE cc w/o encl: See next page DISTRIBUTION:

PUBLIC (Cover letter only)

NON-PUBLIC (Enclosed Revised Draft SE)

PSPB Reading File RidsNrrDpr RidsNrrDprPspb RidsNrrPMMHoncharik RidsNrrLADBaxley RidsOgcMailCenter RidsAcrsAcnwMailCenter RidsNrrDss RidsNrrDssScvb (Robert Dennig)

Ahsan Sallman Rich Lobel ADAMS ACCESSION NOS.: Package ML100690002, Cover letter ML100680573, Revised draft SE ML100680536

  • No major changes to SE input.

NRR-043 OFFICE PLPB/PM PLB/LA SCVB/BC*

PLPB/BC NAME MHoncharik DBaxley EHylton for RDennig SRosenberg DATE 3/12/10 3/11/10 2/1/10 3/22/10 OFFICIAL RECORD COPY

02/3/10 BWR Owners= Group Project No. 691 Mr. Oscar Limpias BWROG, Executive Chairman Entergy Nuclear 1340 Echelon Parkway.

Jackson, MS 39213-8202 olimpia@entergy.com Paul J. Davison BWROG, Executive Vice Chairman Hope Creek Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 paul.davison@pseg.com Mr. Dennis Madison Hatch Vice President Southern Nuclear Operating Co.

11028 Hatch Parkway North Baxley, GA 31515-2010 drmadiso@southernco.com Mr. James F. Klapproth GE-Hitachi Nuclear Energy M/C A50 3901 Castle Hayne Road Wilmington, NC 28401 james.klapproth@ge.com Mr. Frederick Schiffley BWROG, Chairman Exelon Generation Co., LLC.

Cornerstone II at Cantera 4300 Winfield Road Warrenville, IL 60555 frederick.schiffley@exeloncorp.com Mr. Michael Crowthers BWROG, Vice Chairman PPL Susquehanna, LLC 2 North Ninth Street Allentown, PA 18101-1179 mhcrowthers@pplweb.com Mr. Douglas Coleman Chairman, Regulatory Response Group Energy Northwest Columbia Generating Station Mail Drop PE20 P.O. Box 968 Richland, WA 99352-0968 dwcoleman@energy-northwest.com Mr. Craig J. Nichols BWROG, Program Manager GE-Hitachi Nuclear Energy PO Box 780 M/C F12 3901 Castle Hayne Road Wilmington, NC 28402 craig.nichols@ge.com